Model Number Structure. Floatless Level Switch (Basic Type)

Size: px
Start display at page:

Download "Model Number Structure. Floatless Level Switch (Basic Type)"

Transcription

1 Floatless Level Switch (asic Type) CS_61F-G DS_E_4_3 asic uilding-block Controllers That ount Directly to anels for Easier aintenance Easy maintenance with building-block s. Easy identification of operating status with LED operation indicator. Lineup includes models for tropical regions and for high temperatures. Achieve stable detection even in hightemperature environments. Refer to Safety recautions for Floatless Level Controllers. odel Number Structure Some specifications for Series products in this catalog have been discontinued at the end of arch Control Application G: Automatic water and drainage G1: Automatic water with idling prevention or water shortage alarm G2: Automatic water and drainage with abnormal water increase alarm G3: Automatic water and drainage with full and water shortage alarm G4: Automatic water with water level indicator for water and water receiving and prevention of idling due to water shortage I: Liquid level indication and alarm (no two-wire models) 2. Type lank: General-purpose L 2K: Long-distance (for 2 km) L 4K: Long-distance (for 4 km) H: High-sensitivity D: Low-sensitivity R: Two-wire T: High-temperature osition of LED indicator 1

2 Ordering Information Type Set contents General-purpose Long-distance, 2 km Long-distance, 4 km High-sensitivity odel odel odel odel Application G 61F-G ase 1 61F-G * 61F-GL 2K * 61F-GL 4K * 61F-GH nits 1 Application G1 61F-G1 ase 1 61F-G1 * 61F-G1L 2K 61F-G1L 4K 61F-G1H nits 2 Application G2 61F-G2 ase 1 61F-G2 * 61F-G2L 2K * 61F-G2L 4K * 61F-G2H nits 2 Application G3 61F-G3 ase 1 61F-G3 * 61F-G3L 2K 61F-G3L 4K 61F-G3H nits 3 Application G4 61F-G4 ase 1 61F-G4 * 61F-G4L 2K 61F-G4L 4K * 61F-G4H nits 5 K3 Relay 1 Application I 61F-I ase 1 61F-I * 61F-IL 2K 61F-IL 4K nits nits 1 L 2K L 4K H Type Set contents Low-sensitivity 2-wire Tropical environments High-temperature odel odel odel odel Application G 61F-G ase 1 61F-GD 61F-GR 61F-G-TDL * 61F-GT nits 1 Application G1 61F-G1 ase 1 61F-G1D 61F-G1R 61F-G1-TDL * nits 2 Application G2 61F-G2 ase 1 61F-G2D 61F-G2R 61F-G2-TDL * 61F-G2T nits 2 Application G3 61F-G3 ase 1 61F-G3D 61F-G3R 61F-G3-TDL * nits 3 Application G4 61F-G4 ase 1 61F-G4D 61F-G4R 61F-G4-TDL * nits 5 K3 Relay 1 Application I 61F-I ase 1 61F-ID * F-I-TDL * nits nits 1 D R --- T Note: 1. When ordering, specify the desired operating voltage at the end of the model number. Eample: 61F-G [110/22AC] Desired voltage 2. If you order with a standard model number, the corresponding s are also delivered as part of a set. If you order the 61F-G, one is included in the set. * Orders will not be accepted after arch 31, Refer to the following table for the discontinued power voltages. Discontinued at the end of arch F-G G G1 G2 G3 G4 I Voltage odel odel odel odel odel odel 120/24 61F-G 120/24AC 61F-G1 120/24AC 61F-G2 120/24AC 115/23 61F-G2 115/23AC 200/22 61F-G 200/220VAC 220/38 61F-G 220/38AC 120/24 61F-GL 120/24AC 2K 120/24 61F-GL 120/24AC 4K 120/24 61F-GH 120/24AC 61F-G1 220/38AC 61F-G1H 120/24AC 61F-G2 220/38AC 61F-G2L 120/24AC 2K 61F-G2L 120/24AC 4K 61F-G2H 120/24AC 61F-G3 120/24AC 61F-G3 115/23AC 61F-G3 220/38AC 61F-G3H 120/24AC 61F-G4 120/24AC 61F-G4 115/23AC 61F-G4 220/38AC 61F-G4L 120/24AC 4K 61F-G4H 120/24AC 61F-I 120/24AC 61F-I 115/23AC 61F-I 200/22AC 61F-I 220/38AC 115 V 61F-ID 115 VAC 120/24 61F-GT 120/24AC 120/24 61F-G2T 120/24AC 100/20 61F-G-TDL 100/20AC 110/22 61F-G-TDL 110/22AC 61F-G1-TDL 100/20AC 61F-G1-TDL 110/22AC 61F-G2-TDL 100/20AC 61F-G2-TDL 110/22AC 61F-G3-TDL 100/200VAC 61F-G3-TDL 110/22AC 61F-G4-TDL 100/20AC 61F-G4-TDL 110/22AC 61F-I-TDL 100/20AC 2

3 Specifications Standard odels Specifications Items Controlling materials and operating conditions General-purpose Controller (TDL) (see note 1 and 2) For control of ordinary purified water or sewage water Hightemperature Controller 61F-@T (see note 1) For control of ordinary purified water or sewage water in cases where the ambient temperature is high. Long-distance Controllers 61F-@L 2K (for 2 km) 61F-@L 4K (for 4 km) (see note 1) For control of ordinary purified water in cases where the distance between sewage pumps and water s or between receiver s and s is long or where remote control is required. High-sensitivity Controllers 61F-@H (see note 1) For control of liquids with high specific resistance such as distilled water Low-sensitivity Controller 61F-@D (see note 1) For control of liquids with low specific resistance such as salt water, sewage water, acid chemicals, alkali chemicals Two-wire Controller 61F-@R (see note 1) For control of ordinary purified water or sewage water used in combination with Two-wire Electrode Holder (incorporating a resistor of 6.8 kω) It is possible to wire with less than one wiring against general 61F s wiring. Supply voltage 100, 110, 120, 200, 220 or 24AC; 50/60 Hz Operating voltage range 85% to 110% of rated voltage InterElectrode voltage AC AC AC InterElectrode current Appro. 1 ma AC ma. ower consumption : 3.5 VA ma.; G1F-G1@, G1F-G2@, or G1F-I@: 5.5 VA ma.; G1F-G3@: 7.5 VA ma.; G1F-G4@: 14.5 VA ma. InterElectrode operate resistance 0 to appro. 1.8 kω 0 to appro. 1.1 kω InterElectrode release resistance Cable length (see note 3) 0 to appro. 4 kω 0 to appro. 5 kω 0 to appro. 1.8 kω (for 2 km) 0 to appro. 0.7 kω (for 4 km) Appro. 15 k to Ω Appro. 15 k to Ω 4 k to Ω (for 2km) 2.5 k to Ω (for 4km) 1 km ma. 600 m ma. 2 km ma. 4 km ma. Appro. 15 kω to 70 kω (see note 5) Appro. 300 k to Ω Appro. 5 k to Ω Appro. 15 k to Ω 50 m ma. 1 km ma. 800 m ma. Control output 2 A, 22AC (Inductive load: cosφ = 0.4) 5 A, 22AC (Resistive load) Ambient temperature Operating: 10 to 55 C ( 10 to 70 C for 61F-@T) Ambient humidity Operating: 45% to 85% RH Insulation resistance 100 Ω min. (at 50DC) (see note 4) Dielectric strength 200AC, 50/60 Hz for 1 min. (see note 4) Life epectancy Electrical: 500,000 operations min. echanical: 5,000,000 operations min. Weight : Appro. 380 g, G1F-G1@, G1F-G2@, or G1F-I@: Appro. 750 g; G1F-G3@: Appro. 930 g; G1F-G4@: Appro. 1,710 g Note: 1. in the model name represents G, G1, G2, G3, G4, and I. 2. The suffi TDL attached to the model name represents models designed for tropical regions (storage humidity of 45% to 90%). For details, refer to Safety recautions for Floatless Level Controllers. 3. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm 2 ) cabtire cables. sable cable lengths will become shorter as the cable diameter or number of conductors becomes larger. For details, refer to Safety recautions for Floatless Level Controllers. 4. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power terminals and contact terminals, and between Electrode terminals and contact terminals. 5. ossible to use with 15 kω or less, however, this may cause reset failure. 6. High-sensitivity Controllers use advanced operation. When the power voltage is applied, if there are some liquids between the electrodes (ground and operation electrodes), the internal will not operate. When the power voltage is applied, if there are no liquids between the electrodes (ground and operation electrodes), the internal will operate. Advanced Operation With advanced operation, the internal operates as soon as control power is supplied to the G1F and is reset when current flows between the poles. Wiring is the same as for models with sequential operation. 3

4 Internal Circuit Diagrams The schematic diagrams shown below typify the internal connections of the various 61F models. The designations Ta, Tb, and Tc (sometimes referred to collectively as ) may occur more than once in a product, however, the a terminal is always an NO contact, a b terminal is an NC contact, and the c terminal is the common terminal. 61F-G 61F-GT 61F-GL 100, 110 or , 110 T or , , 220 or 24 or , 110 or , 220 or 24 L Ta Tc Tb Ta Tc Tb Ta Tc Tb S0 S1 S2 S0 S1 S2 S0 S1 S2 61F-GH (See note.) 100, 110 or , 220 or 24 H 61F-GD 100, 110 or , 220 or 24 D 61F-GR 100, 110 or , 220 or 24 R Ta Tc Tb Ta Tc Tb Ta Tc Tb S0 S1 S2 S0 S1 S2 S0 S1 S2 4

5 Note: The 61F11H deenergizes when there is water present across the Electrodes, whereas the 61F energizes when there is water present across the Electrodes. Also, the terminal connections of those Controllers provided with LED indicators differ from those which have no indicators. s Item T L H D R Interchangeable with --- rovided rovided Not provided rovided Not provided general-purpose model () Color of band on name plate --- Red Yellow lue lack Green T L E S S S E S S S E S S S Tr1 Tr2 Tr1 Tr2 Tr1 Tr Tb2 Ta2 Tc2 Tc1 Ta1 Tb1 Tb2 Ta 2 Tc2 Tc1 Ta 1 Tb1 Tb2 Ta2 Tc2 Tc1 Ta 1 Tb1 H (see note) E S S S Tr 2 D E S S S R E S S S Tr1 Tr2 Tr1 Tr2 Tr1 Tr Ta 2 Tb2 Tc2 Tc1 Tb1 Ta1 Tb2 Ta 2 Tc2 Tc1 Ta 1 Tb1 Tb2 Ta2 Tc2 Tc1 Ta 1 Tb1 5

6 Automatic Supply and Drainage Control asic Type 61F-G Dimensions: page 14 Automatic Supply Control Automatic Drainage Control 220-VAC power CC 61F-G 0V VAC ower CC 61F-G Ta Tc Tb S0 S1 S2 Ta Tc Tb S0 S1 S2 (See note.) otor S-3S otor (See note.) S-3S Waste water Reservoir Note: e sure to ground the common Electrode (the longest Electrode). Note: e sure to ground the common Electrode (the longest Electrode). Connect Tb to the contactor s coil terminal. ower Supply (for models with 110/220-V power) 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Connect Ta to the contactor s coil terminal. (Do not connect Tb.) ower Supply (for models with 110/220-V power) 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. rinciples of Operation Location rinciples of Operation Location ower 1 ower 1 ump OFF ( indicator ON) ump ON ( indicator ON) ump ON ( indicator OFF) ump OFF ( indicator OFF) drainage The pump stops (indicator ON) when the water level reaches and starts (indicator OFF) when the water level drops below. The pump starts (indicator ON) when the water level reaches and stops (indicator OFF) when the water level drops below. 6

7 Automatic Supply Control with ump Idling revention and Automatic Supply Control with Abnormal Shortage Alarm asic Type 61F-G1 Dimensions: page 14 Automatic Supply Control with ump Idling revention 22AC power 61F-G1 CC Automatic Supply Control with Abnormal Shortage Alarm 22AC power 61F-G1 CC otor So Tb1 Ta1 Tc2 Tb2 S1 S2 ' ' (See note.) S-3S ' ' ' S-3S Alarm () ush button switch otor So Tb1 Ta1 Tc2 Tb2 S1 S2 ' ' (See note.) S-4S Alarm () ush button switch shortage Note: e sure to ground the common Electrode (the longest Electrode). ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Insert a pushbutton switch (NO) between ' and, as shown by the dotted lines above. Do not press the pushbutton if the low-water alarm sounds and the pump stops during normal operation (1 indicator ON, water below '). Test Operation/Recovering from ower Interruptions If the water level is below ' when starting operation or when recovering from a power interruption, press the pushbutton to momentarily close the circuit (1 indicator turns ON) to start the pump. Note: e sure to ground the common Electrode (the longest Electrode). ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Insert a pushbutton switch (NO) between and. If the pump stops when the pushbutton switch is released, press it again. Test Operation/Recovering from ower Interruptions If the water level is below when starting operation or when recovering from a power interruption, press the pushbutton to momentarily close the circuit (1 indicator turns ON) to start the pump. rinciples of Operation Location ower 1 2 rinciples of Operation Location ower 1 2 ump OFF shortage ' ' L (1 indicator ON) (1 indicator OFF) (2 indicator ON) ump OFF ump ON L shortage (2 indicator ON) (2 indicator OFF) (1 indicator OFF) ump ON (2 indicator OFF) The pump starts (2 indicator OFF) when the water level drops below and stops (2 indicator ON) when the water level reaches. When the level of the water drops below ', the pump stops (1 indicator OFF). ump idling is prevented and the alarm sounds. The pump stops (2 indicator ON) when the water level reaches and starts (2 indicator OFF) when the water level drops below. If the water level drops below for any reason, the pump stops (1 indicator OFF) and the alarm sounds. 7

8 Automatic Drainage Control and Supply with Abnormal Increase Alarm asic Type 61F-G2 Dimensions: page 14 Automatic Supply with Overfull Tank Alarm Automatic Drainage Control with Overfull Tank Alarm 22AC power 61F-G2 1 22AC power 61F-G2 1 CC 11 2 CC So Ta1 Tc1 Tb1 Ta2 Tc2 So Ta1 Tc1 Tb1 Ta2 Tc2 S1 S2 S1 S2 (See note.) Alarm S-4S (See note.) Alarm otor Full otor Waste water S-4S Full Reservoir Note: e sure to ground the common Electrode (the longest Electrode). Note: e sure to ground the common Electrode (the longest Electrode). Connect Tb1 to the power. ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Connect Ta1 to the power. ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. rinciples of Operation ump OFF pper L (1 indicator ON) (2 indicator ON) Location ower 1 2 rinciples of Operation L ump ON pper (1 indicator ON) (2 indicator ON) Location ower 1 2 ump ON (2 indicator OFF) ump OFF (2 indicator OFF) drainage The pump starts (2 indicator OFF) when the water level drops below and starts (2 indicator ON) when the water level reaches. If the water level reaches for any reason, the alarm sounds (1 indicator ON). The pump starts (2 indicator OFF) when the water level reaches and stops (2 indicator ON) when the water level drops below. If the water level reaches for any reason, the alarm sounds (1 indicator ON). 8

9 Automatic Supply and Drainage Control with Abnormal Increase and Shortage Alarms asic Type 61F-G3 Dimensions: page 14 Automatic Supply with Abnormal Increase and Shortage Alarms 22AC power 61F-G3 CC Automatic Drainage Control with Abnormal Increase and Shortage Alarms 22AC power 61F-G3 CC Ta Tc Tb 1 2 Lc E5 S0 S1 S2 LH LL Ta Tc Tb 1 2 Lc E5 S0 S1 S2 LH LL Alarm pper L Lower L (See note.) Alarm pper L Lower L (See note.) otor S-5S E5 Full shortage otor Waste water E5 S-5S Full shortage Reservoir Note: e sure to ground the common Electrode (the longest Electrode). Note: e sure to ground the common Electrode (the longest Electrode). Connect Tb to the contactor s coil terminal. ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Connect Ta to the contactor s coil terminal. (Do not connect Tb.) ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. rinciples of Operation ump OFF ump ON E5 pper LH (1 indicator ON) (2 indicator ON) Lower (2 indicator OFF) (3 indicator OFF) LL Locations ower rinciples of Operation ump ON ump OFF E5 LH pper (1 indicator ON) Lower (2 indicator ON) (2 indicator OFF) (3 indicator OFF) LL Locations ower The pump stops (2 indicator ON) when the water level reaches and starts (2 indicator OFF) when the water level drops below. If the water level rises to for any reason, the upper- indicator turns ON and the alarm sounds (1 indicator ON). If the water level drops below for any reason, the lower- indicator turns ON and the alarm sounds (3 indicator OFF). The pump starts (2 indicator ON) when the water level reaches and stops (2 indicator OFF) when the water level drops below. If the water level rises to for any reason, the upper- indicator turns ON and the alarm sounds (1 indicator ON). If the water level drops below for any reason, the lower- indicator turns ON and the alarm sounds (3 indicator OFF). 9

10 Automatic Supply Control with Source Level Indication, revention of ump Idling Due to Shortage, and Indication of Level in Tank asic Type 61F-G4 Dimensions: page 14 Automatic Supply Control with Source Level Indication, revention of ump Idling Due to Shortage, and Indication of Level in Tank ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Insert a pushbutton switch (NO) between and E8, as shown by the dotted lines above. Do not press the pushbutton if the low-water alarm sounds and the pump stops during normal operation (water below ). Test Operation/Recovering from ower Interruptions CC 22 power 61F-G4 1 K3 Relay (See note 2.) V If the water level is below when starting operation or when recovering from a power interruption (2 indicator OFF), press the pushbutton to momentarily close the circuit to start the pump. LL1 LL2 LH1 LH2 L1 L2 H1 H2 S0 S1 S2 TC TC2 TA E8 E7 E6 E5 Elevated water shortage lower Elevated repletion upper Elevated water shortage lower Elevated repletion LL1 LL2 LH1 LH2 L1 L2 H1 H2 upper ushbutton switch (See note 1.) S-5S otor E8 S-4S pper Lower E7 E8 E6 E5 Full shortage Note: e sure to ground the common Electrode (the longest Electrode). rinciples of Operation Insert four Electrodes in the water and five Electrodes in the elevated water. The lower- indicator for the water remains ON while the water level is below (2 indicator OFF). When the water level rises to, the lower- indicator turns OFF (2 indicator ON) and the pump is ready for operation. The upper- indicator in the water lights when the water level reaches (3 indicator ON). The water-shortage indicator for the elevated remains ON while the water level in the elevated is below E7. The indicator turns OFF (1 indicator ON) when the water level rises to E7. The pump stops (5 indicator ON) when the water level reaches E5 and starts (5 indicator OFF) when the water level drops below E6. If the water level reaches for any reason, the abnormal water increase indicator for the elevated turns ON (4 indicator ON). Location ower 10

11 Connection with Three-phase Four-line Circuit When ing power from N-phase to the Controller in three-phase four-line circuit, refer to the following diagrams. Line voltage (R-S, S-T, or R-T): 380 or 415 VAC hase voltage (N-R, N-S, or N-T): 220 or 24AC, 220 or 24AC Supply ower 380 or 415 VAC N * Transformer Ta Tc Tb S0 S1 S2 S3 A Rated voltage: S0-S2: 220 or 24AC * Electromagnetic switch Note: e sure to ground terminal. 11

12 Liquid Level Indication and Alarm asic Type 61F-I Dimensions: page 14 Liquid Level Indication and Alarm ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S VAC power 61F-I 1 CC TC L3 L2 L1 S0 S1 S2 Alarm Intermediate pper Lower L L L (See note.) S-3S pper alarm Intermediate Lower alarm Note: e sure to ground the common Electrode (the longest Electrode). rinciples of Operation When the water level drops below, the lower- indicator turns ON and the alarm sounds (2 indicator OFF). When the water level reaches, the alarm turns OFF and the intermediate indicator turns ON (2 indicator ON). When the water level rises to, the upper- indicator turns ON and the alarm sounds (1 indicator ON). LH L LL pper iddle Lower (1 indicator ON) (1 indicator OFF) (2 indicator ON) (2 indicator OFF) Location ower

13 Two-Wire Automatic Supply and Drainage Control asic Type 61F-GR Automatic Supply Control Automatic Drainage Control 220-VAC power CC 61F-GR 11 R 220-VAC power CC 61F-GR 11 R Ta Tc Tb Ta Tc Tb S0 S1 S2 S0 S1 S2 otor protective S-3SR R (See note.) otor protective (See note.) Waste water R S-3SR Reservoir Note: e sure to ground the common Electrode (the longest Electrode). Note: e sure to ground the common Electrode (the longest Electrode). Connect Tb to the contactor s coil terminal. ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. With 2-wire connections, only two wires are required between the 61F-GR and Electrode Holder, but three wires are required for the Electrodes. The Electrode Holder must be specified for 2-wire connections. (Resistance R is built into Electrode Holders for 2-Wire.) The must also be specified for 2-wire connections. rinciples of Operation ump OFF ( indicator ON) Connect Ta to the contactor s coil terminal. (Do not connect Tb.) ower Supply (for models with 110/220-V power) 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. With 2-wire connections, only two wires are required between the 61F-GR and Electrode Holder, but three wires are required for the Electrodes. The Electrode Holder must be specified for 2-wire connections. (Resistance R is built into Electrode Holders for 2-Wire.) The must also be specified for 2-wire connections. rinciples of Operation ump ON ( indicator ON) ump ON ( indicator OFF) ump OFF ( indicator OFF) drainage The pump stops ( indicator ON) when the water level reaches and starts ( indicator OFF) when the water level drops below. The pump starts ( indicator ON) when the water level reaches and stops ( indicator OFF) when the water level drops below. 13

14 Dimensions Note: All units are in millimeters unless otherwise indicated. Standard odels 61F-G 3 screw ounting Holes Four, 6-dia mounting holes 61F-G1 61F-G2 61F-I Four, 6-dia holes 3 screw ounting Holes Four, 6-dia mounting holes 61F-G3 Four, 6-dia holes 3 screw ounting Holes Four, 6-dia mounting holes Four, 6-dia holes 61F-G4 3 screw ounting Holes Four, 6-dia mounting holes Four, 6-dia holes ALL DIENSIONS SHOWN ARE IN ILLIETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by In the interest of product improvement, specifications are subject to change without notice. 14

15 Terms and Conditions Agreement Read and understand this catalog. lease read and understand this catalog before purchasing the products. lease consult your ORON representative if you have any questions or comments. Warranties. (a) Eclusive Warranty. Omron s eclusive warranty is that the roducts will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period epressed in writing by Omron). Omron disclaims all other warranties, epress or implied. (b) Limitations. ORON AKES NO WARRANTY OR RERESENTATION, ERESS OR ILIED, AOT NON-INFRINGEENT, ERCHANTAILITY OR FITNESS FOR A ARTICLAR ROSE OF THE RODCTS. YER ACKNOWLEDGES THAT IT ALONE HAS DETERINED THAT THE RODCTS WILL SITALY EET THE REQIREENTS OF THEIR INTENDED SE. Omron further disclaims all warranties and responsibility of any type for claims or epenses based on infringement by the roducts or otherwise of any intellectual property right. (c) uyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with uyer responsible for labor charges for removal or replacement thereof) the non-complying roduct, (ii) repair the non-complying roduct, or (iii) repay or credit uyer an amount equal to the purchase price of the non-complying roduct; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or epenses regarding the roducts unless Omron s analysis confirms that the roducts were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any roducts by uyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of roducts in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See or contact your Omron representative for published information. Limitation on Liability; Etc. ORON COANIES SHALL NOT E LIALE FOR SECIAL, INDIRECT, INCIDENTAL, OR CONSEQENTIAL DAAGES, LOSS OF ROFITS OR RODCTION OR COERCIAL LOSS IN ANY WAY CONNECTED WITH THE RODCTS, WHETHER SCH CLAI IS ASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIAILITY. Further, in no event shall liability of Omron Companies eceed the individual price of the roduct on which liability is asserted. Suitability of se. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the roduct in the uyer s application or use of the roduct. At uyer s request, Omron will provide applicable third party certification documents identifying ratings and ations of use which apply to the roduct. This information by itself is not sufficient for a complete determination of the suitability of the roduct in combination with the end product, machine, system, or other application or use. uyer shall be solely responsible for determining appropriateness of the particular roduct with respect to uyer s application, product or system. uyer shall take application responsibility in all cases. NEVER SE THE RODCT FOR AN ALICATION INVOLVING SERIOS RISK TO LIFE OR ROERTY OR IN LARGE QANTITIES WITHOT ENSRING THAT THE SYSTE AS A WHOLE HAS EEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE ORON RODCT(S) IS ROERLY RATED AND INSTALLED FOR THE INTENDED SE WITHIN THE OVERALL EQIENT OR SYSTE. rogrammable roducts. Omron Companies shall not be responsible for the user s programming of a programmable roduct, or any consequence thereof. erformance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. roduct specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the roduct may be changed without any notice. When in doubt, special part numbers may be assigned to fi or establish key specifications for your application. lease consult with your Omron s representative at any time to confirm actual specifications of purchased roduct. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. ORON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. (c)copyright ORON Corporation 2018 All Right Reserved.

Model Number Structure

Model Number Structure Floatless Level Switch (asic Type) 61F-G@ CS_61F-G DS_E_4_1 asic uilding-block Controllers That ount Directly to anels for Easier aintenance Easy maintenance with building-block Relay nits. Easy identification

More information

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia. Infrared Thermosensor CSM DS_E_3_2 Achieve Low-cost Measurements with an Infrared Thermosensor. The has an electromotive output as high as that of a thermocouple, thus connecting directly to the thermocouple

More information

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor Humidity Sensor Temperature/Humidity Sensor ES2-THB CSM ES2-THB_DS_E_3_2 Detect Humidity within an Accuracy of ±3% in a Compact Body. Set Provides Superior Humidity Control and Temperature/ Humidity Control.

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

Model Number Structure

Model Number Structure Element Burnout Detector Accurate Detection of Element Burnout Regardless of Capacities Accurately detects a burned heater element or elements incorporated by a molding machine or packing machine and outputs

More information

Scale 0: 10 k Scale 50: 10 k (see note 2)

Scale 0: 10 k Scale 50: 10 k (see note 2) Water Leak Alarm/Detector Eliminate Problems Caused from Water Leakage 0 to 50 k variable operating resistance to detect virtually any liquid. Two types available: Water Leak Alarm (61F-WLA) and plug-in

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level Sensor EK-L CSM_EK-L_DS_E_4_ Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to 11 mm or 1 to mm Built-in

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor Humidity Sensor Temperature/Humidity Sensor ES2-THB-N Detect Humidity within an Accuracy of ±3% in a Compact Body. Set Provides Superior Humidity Control and Temperature/ Humidity Control. Employs high-polymer-resistive

More information

onlinecomponents.com

onlinecomponents.com Reflective Mapping CSM DS_E_2_1 Ideal for Mapping Liquid Crystal Glass Plates on Cassette Trays Be sure to read Safety Precautions on page 3. Features Detects glass plates without being influenced by the

More information

Ultrasonic Proximity Sensor

Ultrasonic Proximity Sensor Ultrasonic Proximity Sensor Compact, Cylindrical Ultrasonic Proximity Sensor with Separate Amplifier Unit Stable operation for a variety of objects regardless of color, transparency, or material (metallic

More information

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors MEMS Thermal Sensors D6T Contactless measurement creating energy-efficient and comfortable living spaces Application examples provided in this document are for reference only. In actual applications, confirm

More information

Installation & Operation Manual

Installation & Operation Manual Humidity & Temperature Sensor 086 Accessories 086_D 08/12 Replaces: New Installation & Operation Manual Introduction The Humidity & Temperature Sensor 086 can be connected to select tekmar thermostats

More information

Original instructions JSNY7 Magnetic switch

Original instructions JSNY7 Magnetic switch Original instructions JSNY7 Magnetic switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.jokabsafety.com Read and understand this document Please read and understand this

More information

XT Series Thermostats

XT Series Thermostats ISO 9001 Explosion-Proof & Moisture Resistant XT Series Thermostats Installation, Operation, & Maintenance Instructions XTWA Thermostat XTWL Thermostat XTB Thermostat Part No.MI133.Rev.2.00 Date of Issue:

More information

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts ISO 9001 BX Series Installation, Operation, Maintenance Instructions & Spare Parts WARNING WARNING. The BX convection heater is a heavy duty baseboard designed for use in industrial environments and is

More information

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only! - Data Brochure Programmable Thermostat 510 and 511 D 510 02/12 Table of Contents Display / Keypad Operation... pg 1 Display Symbols... pg 2 General... pg 2-3 Sequence of Operation... pg 4 Installation

More information

Annuciator Logic Controllers

Annuciator Logic Controllers C B0 C C5 C C6 C C7 A B A B A B A B A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 5 Annuciator Logic Controllers 68 c5 c6 c7 B B B B B5 B6 B7 B8 B9 B0 B B B B B5 B6 C0 BUZZER RETURN BZ M / BZ CTROL SIGNAL LAMP DC() DC()

More information

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector CAUTION & SYMBOL DEFINITIONS: CAUTION: Gives detailed description of different situations to avoid or not avoid for the proper operation of the

More information

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage

More information

Original instructions Sense7-series Non-contact coded safety switch

Original instructions Sense7-series Non-contact coded safety switch Original instructions Sense7-series Non-contact coded safety switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage Read and understand this document Please

More information

- User Brochure tekmarnet 4 Setpoint Control 161

- User Brochure tekmarnet 4 Setpoint Control 161 - User Brochure tekmarnet 4 Setpoint Control 161 U 161 08/07 Congratulations on the purchase of your tekmar setpoint control with communication. The setpoint control combines easy-to-use programming with

More information

Current monitoring relay, overcurrent, undercurrent and current window. MCU024R2, MCU230R2

Current monitoring relay, overcurrent, undercurrent and current window. MCU024R2, MCU230R2 Current monitoring relay, overcurrent, undercurrent and current window. MCU024R2, MCU230R2 Current monitoring relay; in DIN rail box with 22,5 mm width, especially designed for monitoring the current in

More information

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor CSM DS_E_4_7 Excellent PET Bottle Detection New detection method that is independent of bottle shape, position, and contents. Automatic

More information

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07 Module de relais Relay Module Manuel de l utilisateur 301RW User Manual ERP 511397 02/07 Relay Module 301R User Manual ERP 511397 2/07 Notices and Trademarks Copyright by Honeywell International Inc.

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Radiant Thermostat 519 519_D 06/16 Zoning Replaces: 03/13 Introduction The Radiant Thermostat 519 accurately controls the room and/or floor temperature for a hydronic heating

More information

- User Brochure Programmable Thermostat 510

- User Brochure Programmable Thermostat 510 - User Brochure Programmable Thermostat 510 U 510 09/09 Congratulations on the purchase of your tekmar programmable thermostat. This thermostat combines easy-to-use programming with advanced features to

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS N99V /99 PRM Polarity Reversing Module What is the PRM? The PRM Polarity Reversing Module is used to reverse the polarity of the positive and negative voltages powering smoke

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

WATLOW IND. Thermostat Control Installation & Maintenance Manual I&M NUMBER

WATLOW IND. Thermostat Control Installation & Maintenance Manual I&M NUMBER age:1 re Installation Check to make sure that the thermostat received is the same as that ordered. Check capillary for kinks and damage to the bulb Safety Fire and electrical shock may result if thermostats

More information

Quick Set-up Guide. 1. Location 2. Remove Mounting Base. 4. Switch Settings. 3. Install Mounting Base. 5. Wiring. Snow Melting Control PM-653

Quick Set-up Guide. 1. Location 2. Remove Mounting Base. 4. Switch Settings. 3. Install Mounting Base. 5. Wiring. Snow Melting Control PM-653 Quick Set-up Guide Snow Melting Control PM-653 1. Location 2. Remove Mounting Base Interior Wall Behind Door 5 feet 1.5 m Exterior Wall 3. Install Mounting Base 4. Switch Settings Base 3 ¼" (83 mm) Stud

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement

More information

SKORPION Process Air Heater

SKORPION Process Air Heater OPERATING INSTRUCTIONS 2/6/2018 SKORPION Process Air Heater Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow all applicable electrical codes and use

More information

Duct Mount. Installation Instructions

Duct Mount. Installation Instructions Duct Mount Installation Instructions 00809-0600-4975 Legal Notice The Flame Detector described in this document is the property of Rosemount. No part of the hardware, software, or documentation may be

More information

Installation & Operation Manual

Installation & Operation Manual 519_D Radiant Thermostat 519 03/13 Zoning Replaces: New Installation & Operation Manual Introduction The Radiant Thermostat 519 accurately controls the room and/or floor temperature for a hydronic heating

More information

Electric Duct Heaters

Electric Duct Heaters Electric Duct Heaters 12541_Tutco_Catalog.indd 1 3/4/11 8:46:01 AM TYPICAL HEATER CONSTRUCTION TUTCO, the world s largest supplier of open coil heating elements, produces the highest quality products in

More information

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL 95 Methodist Hill Drive Rochester, NY 14623 Phone: US +1.585.321.5800 Fax: US +1.585.321.5219 www.spectracomcorp.com Part Number 8143-5000-0050

More information

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector IMPORTANT READ THIS FIRST....3 CAUTIONS... 3 AVOIDING NUISANCE ALARMS... 3 STANDARD FEATURES... 4 AVAILABLE OPTIONS... 4 PARTS DESCRIPTION... 5 FRONT PANEL

More information

M3050 Detector Operator s Manual

M3050 Detector Operator s Manual FABRICON SYSTEMS ALBERTA 2008 INC. Keeping you in Front M3050 Detector Operator s Manual Telephone: (403)652-2127 Mailing Address: Shipping Address: Fax: (403)652-3027 Box 5996 402 Ellis Crescent S.E Email:

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS HUHAA Series Modular Unit Heaters Dear Owner, FILE #E21609 Installation & Maintenance Instructions Congratulations! Thank you for purchasing this new heater manufactured by a division of Marley Engineered

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual Installation and Operation Manual Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control Pump-Lead-Lag Warning This Heat-Timer control is strictly an operating control; it should

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

installation instructions Fan Tray System FTA-3/FTA-6

installation instructions Fan Tray System FTA-3/FTA-6 installation instructions Fan Tray System FTA-3/FTA-6 (3 Fan System) (6 Fan System) THANK YOU Thank you for purchasing the Fan Tray System. Please read these instructions thoroughly before installing this

More information

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control Installation and Operation Manual Temperature and Pressure Monitoring for Heating and Cooling Applications Temperature Monitoring Control VALVE OPEN ALARM System= 128 o F Alarm At= 130 o F RESET /BACK

More information

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F Temperature Controller 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes Accurate to ±0.5% of full scale Multiple temperature scale ranges allow flexibility to match application Field-selectable

More information

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA Instruction Manual: For more information visit: www.eatonelectrical.com Effective: 01/06 PVL Page 2 Effective Date: 01/06

More information

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS. DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS. DESIGNED BY FIRE FIGHTERS / FOR FIRE FIGHTERS At American Fire & Safety Equipment we focus on providing the most hardened, reliable, products, which can be

More information

R1000 / R1040 / R1080

R1000 / R1040 / R1080 R1000 / R1040 / R1080 1 Zone Temperature Controller: Heat-only Heating-off-cooling Three-point stepping DIN-Format: 96mm x 96mm / 48mm x 96mm / 96mm x 48mm Description and operating manual ELOTECH Industrieelektronik

More information

Expanded Backup Control Installation & Operator s Instruction Manual

Expanded Backup Control Installation & Operator s Instruction Manual Installation & Operator s Instruction Manual March 2004 CTB Inc. Warranty CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free from defects in material or workmanship

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

Inline Heater for Solvent or Gas. Installation and Operation Manual

Inline Heater for Solvent or Gas. Installation and Operation Manual SH Series Inline Heater for Solvent or Gas Installation and Operation Manual This instruction manual explains the basic operation of the Process Technology inline solvent or gas heater. We recommend reading

More information

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA Model 20201/20201-A/20201-B Wind Sensor Heater User's Manual All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA www.allweatherinc.com 20201 Wind Sensor Heater User's Manual CONTENTS INTRODUCTION...1

More information

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1 Chore-Logic User manual Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07 Page 1 Warranty Chore-Time Hog Production Systems, a division of CTB, Inc., ( Chore-Time ), warrants each new Chore-Time product

More information

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat 6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat Introduction The Airpax 6600 series is a RoHS compliant, positive snap action, single pole / single throw, sub-miniature bimetallic thermostat

More information

FW-RA-LED Remote Multiplex Annunciator Panels

FW-RA-LED Remote Multiplex Annunciator Panels FW-RA-LED Remote Multiplex Annunciator Panels WIRING and INSTALLATION INSTRUCTION LNOTICE All information, documentation, and specifications contained in this manual are subject to change without prior

More information

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC MEMS Air Velocity Sensor Unique dust separating structure, developed by OMRON, in a compact and highly efficient FLOW-SENSOR. Unique dust segregation structure. +/-10% Full-Scale repeatable accuracy achieves

More information

Panel Mounted Heat Exchangers by Dantherm, Inc.

Panel Mounted Heat Exchangers by Dantherm, Inc. Panel Mounted Heat Exchangers by Dantherm, Inc. PRODUCT INFORMATION MANUAL C0028 003 Pinnacle OM Manual Rev AB Page 1 of 14 Dantherm, Inc. 110 Corporate Drive, Suite K Spartanburg, SC 29303 Tel # +1 864

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM D-tect Systems 11814 South Election Road, Suite 200 Draper, UT 84020 www.dtectsystems.com 1 Introduction The mini

More information

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products: Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2

More information

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL. Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3

More information

OKB, OKD, & OKH Series

OKB, OKD, & OKH Series ISO 9001 Infrared Radiant Heaters OKB, OKD, & OKH Series Installation, Operation, Maintenance Instructions & Spare Parts CE Certified HIGH TEMPERATURE, RISK OF FIRE, FIRE/EXPLOSION HAZARD. During operation,

More information

CD6102 / CD6102 OC / CD6102-2

CD6102 / CD6102 OC / CD6102-2 PreView Display CD6102 / CD6102 OC / CD6102-2 Operating Manual www.previewradar.com PATENTS Patented under one or more of the following U.S. Patents: 5345471, 5523760, 5457394, 5465094, 5512834, 5521600,

More information

Model 5190-E Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe Model 5190-E Temperature/Humidity Probe User s Manual Rev. D All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com Copyright 2010, All Weather, Inc. All Rights

More information

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1 Table of Contents 1. Warranty... 3 2. MTCC-01 overview... 4 2.1. MTCC-01 specification... 4 2.2. TE cooled detector temperature stabilization

More information

USER MANUAL SAVE THESE INSTRUCTIONS

USER MANUAL SAVE THESE INSTRUCTIONS USER MANUAL Model: PM50 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067

More information

Model 5190-F Temperature/Humidity Probe

Model 5190-F Temperature/Humidity Probe Model 5190-F Temperature/Humidity Probe FAA APPROVED ECP234 2017 Mar 13 NOT FAA APPROVED User s Manual Rev. C All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com

More information

K7L-U/K7L-UD. Liquid Leakage Sensor Amplifiers for Long-distance Wiring. Enables longdistance. up to 400 m.

K7L-U/K7L-UD. Liquid Leakage Sensor Amplifiers for Long-distance Wiring. Enables longdistance. up to 400 m. New Product News Liquid Leakage Sensor Amplifiers for Long-distance Wiring K7L-U/K7L-UD A new long-distance wiring model joins the K7L Series. The industry's smallest size and longest wiring ability ideal

More information

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual Installation and Operation Manual Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control PLL Pump-Lead-Lag Warning This Heat-Timer control is strictly an operating control; it

More information

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction

More information

Clean Steam Generators

Clean Steam Generators Clean Steam Generators Steam for Humidification Steam for Autoclaves Clean steam using existing steam as an energy supply Introducing the CX System for clean steam generation in large facilities. It's

More information

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION G Series (Model B) Convector Heater for Hazardous Locations Type G-Series Convection Heaters are designed for use in Class I, Div. I hazardous environments. Units without control options are suitable for

More information

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TRACON MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TABLE OF CONTENTS GPT 130 Overview... 2 Installation... 3 Power Source and Load Connection... 4 Temperature Sensor Installation... 5 Panel

More information

STATUS ALARM HISTORY ALARM RESET

STATUS ALARM HISTORY ALARM RESET Instruction Manual Model 1582-42L Data Switch February 1999, Rev 0 CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 ONLINE SWITCH RESET MAN

More information

AFA 500 FUME HOOD ALARMS

AFA 500 FUME HOOD ALARMS AFA 500 FUME HOOD ALARMS Operating and Instruction Manual 19/7/03 Model AFA 500 Built-in or Remote sensor 2 Relay inputs 1 Relay output Com port Used for alarm indication and monitoring on Fume Cupboards

More information

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S NIR-50-325 RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 8 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales

More information

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS (I)COMP-COOL50 (I)COMP-COOL50P Thank you for purchasing the (I)COMP-COOL50/(I)COMP-COOL50P Component Coolers. Please

More information

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT OWNER'S MANUAL FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT P/N E055-71520301 P/N E055-71520304 72 74 C OOL AUTO HEAT 70 2- or 4-pipe configurable Dual or Single Setpoint Very easy to program Large, easy

More information

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual Replace the following pages of Document Number 50734 (I56-993-01/D770-19-00), Revision B with the corresponding revised

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632

More information

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT Omnipolar Digital Hall-effect s: 005917 Issue 3 Datasheet FEATUES Simple activation from a North pole or a South pole and sensitive magnetics Low voltage 3 Vdc capability Built-in reverse polarity protection

More information

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

RR-PM1200 OPERATING AND PROGRAMMING GUIDE ALARM LOCK RR-PM1200 OPERATING AND PROGRAMMING GUIDE ALARM LOCK 2000 OI261 08/00 1 INTRODUCTION The Alarm Lock Remote Release PowerMag is an innovative 1200 lb. electromagnetic locking system with infrared

More information

Blade Series Heat Exchanger Operation and Installation

Blade Series Heat Exchanger Operation and Installation Blade Series Heat Exchanger Operation and Installation *IMPORTANT* For safe and satisfactory operation, please read the following instructions. Keep these instructions for future reference. Some information

More information

Remote Relay Module (RRM)

Remote Relay Module (RRM) Remote Relay Module (RRM) Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like

More information

Technical Data. Installation

Technical Data. Installation Technical Services: Tel: (800) 81-91 / Fax: (800) 791-5500 Model 51 (1) Riser Manifold 1-1/ thru 6 Inch (DN40 thru DN150) For NFPA 1 Sprinkler Systems Customer Service/Sales: Tel: (15) 6-0700 / (800) 5-651

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS U S E R M A N U A L Models: PM15F (shown) PM15P SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: 610-262-6090 Northampton,

More information

Buying goods/services

Buying goods/services General contractual provisions Buying goods/services These are the only contractual provisions that apply between Fire and Emergency New Zealand and the Contractor. If any other provision is to apply or

More information

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow

More information

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier MANUAL 8/12/05 INSTALLATION, OPERATION & MAINTENANCE Commercial High Efficiency Heat Pipe Dehumidifier Model BKP TM 100 Heat Pipe Technology, Inc. 6904 Parke East Blvd. Tampa FL 33610 Tel: (813) 470-4250

More information

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL Andover Corporation 4 Commercial Drive Salem, New Hampshire 03079-2800 Tel: (603) 893-6888 US Toll Free: (888) 893-9992 Fax: (603) 893-6508 Email:

More information

Advanced Ultraviolet Burner Controller

Advanced Ultraviolet Burner Controller No. CP-SS-7E Advanced Ultraviolet Burner Controller Model AUR300C/AUR30C Overview The AUR300C Advanced Ultraviolet Burner Controller and AUR30C Advanced Ultraviolet Burner Controller with Communication

More information

Protocol Station Remote Alarm

Protocol Station Remote Alarm ADI 5135-C Certified ISO 9001 Protocol Station Remote Alarm 529 5135-01-120 529 5135-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Ion Endeavor Controller Digital Level Control with Alternation Page 1 of 8 General Overview The Ion Endeavor is a pump controller that senses a water level of up to 72", has a configurable water level/pump

More information

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual EQUIPMENT Operation Manual Loctite SD15 Heat Controller Part Number 1667508 1 TABLE OF CONTENTS 1 Please Observe The Following... 3 1.1 Emphasized Sections... 3 1.2 For Your Safety... 3 1.3 Unpacking and

More information

MaxLite LED MICRO-T PANEL

MaxLite LED MICRO-T PANEL ` Installation Instructions General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all

More information

INSTALLATION INSTRUCTIONS TALKBACK MODULE

INSTALLATION INSTRUCTIONS TALKBACK MODULE 273 Branchport Avenue Long Branch, N.J. 07740 (732) 222-6880 MODEL NUMBER: TBM-101 FCC REGULATIONS: INSTALLATION INSTRUCTIONS TALKBACK MODULE This equipment complies with Part 68 of the FCC Rules. On the

More information

6502B RF Distribution

6502B RF Distribution 6502B RF Distribution User Guide Revision A - March 2004 Part Number 15247-201 Table of Contents Table of Contents About this User Guide Purpose...................................................... 1

More information

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller No. CP-SS-7E Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD00C Advanced Ultraviolet Flame Detector. This AUR300C controls

More information

View the expanded manual: GEN5

View the expanded manual:   GEN5 View the expanded manual: http://aeotec.com/support GEN5 1 Aeotec by Aeon Labs Door/Window Sensor. The Aeotec by Aeon Labs Door/Window Sensor Gen5 provides your Z-Wave network with the intelligence required

More information