XX 0.25 GI VX. The other members of the series are also optimal for quad-element pyroelectric detectors of the type:
|
|
- Paul Singleton
- 6 years ago
- Views:
Transcription
1 XX 0.25 GI VX The lens arrays of Fresnel Technologies XX 0.25 GI VX series shown in the accompanying data sheets are intended to be used in passive infrared motion detector devices. They are optimized for dual-element pyroelectric detectors; the CM types are also optimized for quad-element pyroelectric detectors with this arrangement: The other members of the series are also optimal for quad-element pyroelectric detectors of the type: The flanged and -NF packages are suitable for both TO-5 (tall) and TO-39 (short) pyroelectric detector cans; they must be pushed onto the pyroelectric detector far enough for the face of the detector to seat on the surface indicated in Figures 2 and 4, and the spacers shown in Figures 2 and 4 are recommended to be placed between the pyroelectric detector and the circuit board. The -SMD package variant is intended for use with surface mounted pyroelectric detectors, which need no spacer; its mounting geometry is shown in Figures 5 and 6. Please be sure to note the position within the package of the surface mounted detector you are using, as different manufacturers place the elements differently relative to the package. Figures 9 to 23 illustrate the beam patterns for the arrays. Each lens array s beam pattern is dependent on the alignment of the 3 Roman numerals on the lens array to the pyroelectric detector s tab or the corresponding orientation of the surface mounted pyroelectric detector, as shown in Figures 1, 3, 7, and 8. Each data sheet indicates our suggested mounting alignment for each different beam pattern. The figures postulate a dual-element or quad-element detector with a 110 acceptance angle and a mounting height of 1 meter (3 feet) for the types designed AA (Animal Alley), 1.3 meters (4 feet) for the WS (Wall Switch) types, 1 or 1.3 meters for the VB (Vertical Barrier) types, and 2.5 meters (8 feet) for the CM (Ceiling Mount) types. It is reasonable to expect CM detection of full body motion over a diameter of 8 meters (26 feet), small hand motion over a diameter of 6.5 meters (22 feet) from a mounting height of 3 meters (10 feet); a diameter of 11 meters (36 feet) for full body motion, and 5 meters (16 feet) for small hand motion from a mounting height of 5.2 meters (17 feet), using a quad-element pyroelectric detector. Similarly, AWV3 can be expected to cover an aisle 15 meters (45 feet) long x 1.7 meters (5.5 feet) wide from a mounting height of 5.2 meters (17 feet), 15 meters (44 feet) long from a mounting height of 6.7 meters (22 feet), 11 meters (36 feet) long from a mounting height of 8 meters (26 feet), and 10 meters (32 feet) long from a mounting height of 10 meters (32 feet), with a good-quality dual-element pyroelectric detector. VB V4 can be expected to cover up to a distance of 4.6 meters (15 feet) from the unit for full-body motion, 2.7 meters (9 feet) for small hand motion with a dual-element pyro electric detector. WS V4 will cover an area 7 meters (23 feet) deep by 8 meters (26 feet) wide for full-body motion, 3.7 meters (12 feet) deep by 5 meters (16 feet) wide for small hand motion with a dual-element pyroelectric detector. CM 0.25 GI V1 WS AA 0.25 GI V1 CM 0.25 GI V2 WS AA 0.25 GI V2 CM 0.25 GI V3 WS VB AW 0.25 GI V3 CM 0.25 GI V4 f CM 0.25 GI V5 WS VB AW 0.25 GI V4 Copyright Fresnel Technologies, Inc
2 XX 0.25 GI VX Mounting Geometry (Spacers are required - see Figure 2) A A Lens slots that fit onto a pyroelectric detector's tab are labeled l, ll and lll Ribs hold lens in place on pyroelectric detector can Runner - next to symbol II Slots labeled l, ll and lll Slots drawing and design 2012 Figure 1
3 XX 0.25 GI VX TO-39 (short) and TO-05 (tall) Pyroelectric Mounting Geometry SECTION A-A Ø 9.0 mm 2.5 mm 10.7 mm 2.8 mm 2.8 mm 11.2 mm 3.0 mm 3.9 mm Ø 8.7 mm SECTION A-A Surface 3.6 mm 2.5 mm Spacer TO-39 CAN SECTION A-A Surface 4.6 mm 1.5 mm Spacer TO-5 CAN drawing and design 2012 Figure 2
4 XX 0.25 GI VX-NF Mounting Geometry (Spacers are required - see Figure 4) A A Ribs hold lens in place on pyroelectric detector can Identifying Marks Labled 1, ll and lll Slots drawing and design 2014 Figure 3
5 XX 0.25 GI VX-NF TO-39 (short) and TO-05 (tall) Pyroelectric Mounting Geometry SECTION A-A Ø 9.0 mm 2.5 mm 10.7 mm 2.9 mm 2.8 mm 11.2 mm 3.2 mm 3.9 mm Ø 8.7 mm SECTION A-A Surface 3.6 mm 2.5 mm Spacer TO-39 CAN SECTION A-A Surface 4.6 mm 1.5 mm Spacer TO-5 CAN drawing and design 2014 Figure 4
6 XX 0.25 GI VX-SMD Mounting Geometry Sensitive elements are not in the center of the package on all Surface Mounted Detectors Crush ribs hold lens in place Figure 5
7 XX 0.25 GI VX-SMD Mounting Geometry TOP VIEW 25.5 A-A 9mm D 9.8mm D SECTION A-A 6mm R 7.8mm Plane of the pyroelectric detector's sensitive elements 5.3mm 2.8mm 2.2mm 1.3mm 2.8mm 8.7mm Figure 6
8 XX 0.25 GI VX-SMD Mounting Geometry - Circuit Board Orientation mm diameter 0.1 mm offset from pins Ceiling 1.2 mm wide (2x circuit board cutouts for pins) Lens outline for reference only Floor 9.9 mm diameter 0.1 mm offset from pins Orientation mm diameter 0.1 mm offset from pins Ceiling 1.2 mm wide (2x circuit board cutouts for pins) Lens outline for reference only Floor 9.9 mm diameter offset 0.1 mm from pins Figure 7
9 XX 0.25 GI VX-SMD Mounting Geometry - Circuit Board Orientation mm diameter 0.1 mm offset from pins Ceiling 9.9 mm diameter 0.1 mm offset from pins Lens outline for reference only Floor 1.2 mm wide (2x circuit board cutouts for pins) Orientation mm diameter 0.1 mm offset from pins Aisleway Direction 9.9 mm diameter 0.1 mm offset from pins Lens outline for reference only 1.2 mm wide (2x circuit board cutouts for pins) Figure 8
10 CM 0.25 GI V1 CM 0.25 GI V1 CM 0.25 GI V1-NF: CM 0.25 GI V1-SMD: (8ft) : See Figure 7, Orientation (7.5FT) 2.2 (7.5ft) (15ft) Figure 9
11 CM 0.25 GI V2 CM 0.25 GI V2: 2. (6.5ft) 2. (6.5ft) CM 0.25 GI V2-NF: CM 0.25 GI V2-SMD: (8ft) : See Figure 7, Orientation 1 (7.9ft) (7.9ft) (15ft) Figure 10
12 CM 0.25 GI V3 CM 0.25 GI V3: 2. (6.5ft) 2. (6.5ft) CM 0.25 GI V3-NF: CM 0.25 GI V3-SMD: (8ft) : See Figure 7, Orientation 1 (7.9ft) (7.9ft) (15ft) Figure 11
13 CM 0.25 GI V4 CM 0.25 GI V4: CM 0.25 GI V4-NF: CM 0.25 GI V4-SMD: : See Figure 7, Orientation 1 (8ft) 3. (10ft) 2.2 (7.5FT) 2.2 (7.5ft) (15ft) drawing and design 2017 Figure 12
14 CM 0.25 GI V5 CM 0.25 GI V5 CM 0.25 GI V5-NF: CM 0.25 GI V5-SMD: (8ft) : See Figure 7, Orientation 1 5.8m (19ft) 2.2 (7.5FT) 2.2 (7.5ft) (15ft) 5.8m (19ft) drawing and design 2017 Figure 13
15 WS AA 0.25 GI V1 For WS (wall switch) pattern, put pyroelectric detector's tab in slot I. WS AA 0.25 GI V1: (16.2) 180 WS AA 0.25 GI V1-NF: (16.4ft) WS AA 0.25 GI V1-SMD: 1.2m (4ft) : See Figure 7, Orientation 1 6.1m (20ft) Figure 14
16 WS AA 0.25 GI V1 For AA (animal alley) pattern, put pyroelectric detector's tab in slot III. WS AA 0.25 GI V1: (16.2) 180 WS AA 0.25 GI V1-NF: (16.4ft) WS AA 0.25 GI V1-SMD: 18 : See Figure 8, Orientation 3 1.2m (4ft) 6.1m (20ft) Figure 15
17 WS AA 0.25 GI V2 For WS (wall switch) pattern, put pyroelectric detector's tab in slot III. 1 (32.8ft) WS AA 0.25 GI V2: (16.2) 120 WS AA 0.25 GI V2-NF: (16.4ft) 1 (32.8ft) WS AA 0.25 GI V2-SMD: : See Figure 7, Orientation 1 1.2m (4ft) 7.6m (25ft) Figure 16
18 WS AA 0.25 GI V2 For AA (animal alley) pattern, put pyroelectric detector's tab in slot III. 1 (32.8ft) WS AA 0.25 GI V2: (16.2) 120 WS AA 0.25 GI V2-NF: (16.4ft) 1 (32.8ft) WS AA 0.25 GI V2-SMD: : See Figure 8, Orientation m (4ft) 7.6m (25ft) Figure 17
19 WS VB AW 0.25 GI V3 For WS (wall switch) pattern, put pyroelectric detector's tab in slot I or III. 1 (32.8ft) WS VB AW 0.25 GI V3: (16.2) 120 WS VB AW 0.25 GI V3-NF: (16.4ft) 1 (32.8ft) WS VB AW 0.25 GI V3-SMD: : See Figure 7, Orientation 1 1.2m (4ft) 9.1m (30ft) 18 Figure 18
20 WS VB AW 0.25 GI V3 For VB (vertical barrier) pattern, put pyroelectric detector's tab in slot II. (8ft) WS VB AW 0.25 GI V3: (8ft) 6.7m (22ft) WS VB AW 0.25 GI V3-NF: (16.4ft) 98 WS VB AW 0.25 GI V3-SMD: (16.4ft) : See Figure 7, Orientation 2 6.7m (22ft) 9.1m (30ft) Figure 19
21 WS VB AW 0.25 GI V3 For AW (aisleway) pattern, put pyroelectric detector's tab in slot I or III. WS VB AW 0.25 GI V3: Aisleway direction 1. (5ft) 1. (5ft) WS VB AW 0.25 GI V3-NF: 8m (26ft) 4.6m (15ft) 4.6m (15ft) 8m (26ft) (8ft) 4.6m (15ft) WS VB AW 0.25 GI V3-SMD: 7.6m (25ft) 9m (30ft) : See Figure 8, Orientation 4 Figure 20
22 WS VB AW 0.25 GI V4 For WS (wall switch) pattern, put pyroelectric detector's tab in slot I or III. WS VB AW 0.25 GI V4: (16.2) 180 WS VB AW 0.25 GI V4-NF: (16.4ft) WS VB AW 0.25 GI V4-SMD: : See Figure 7, Orientation 1 1.2m (4ft) 7.6m (25ft) 18 Figure 21
23 WS VB AW 0.25 GI V4 For VB (vertical barrier) pattern, put pyroelectric detector's tab in slot II. (8ft) WS VB AW 0.25 GI V4: (8ft) WS VB AW 0.25 GI V4-NF: (16.2) WS VB AW 0.25 GI V4-SMD: (16.4ft) : See Figure 7, Orientation 2 Figure 22
24 WS VB AW 0.25 GI V4 For AW (aisleway) pattern, put pyroelectric detector's tab in slot I or III. WS VB AW 0.25 GI V4: Aisleway direction 1m (3ft) 1m (3ft) WS VB AW 0.25 GI V4-NF: (16.4ft) (16.2) (8ft) 4.6m (15ft) WS VB AW 0.25 GI V4-SMD: : See Figure 8, Orientation 4 8m (27ft) Figure 23
EXTRA WIDE ANGLE ARRAYS EWA 0.3 GI V1 EWA 0.53 GI V1 EWA 1.35 GI V1 ANIMAL ALLEY ARRAYS AA 0.53 GI V1 AA 0.53 GI M1 AA 0.9 GI M1.
VARIOUS PIR ARRAYS The various Fresnel Technologies lens arrays shown in the accompanying data sheets are intended to be used in passive infrared motion detector devices. They are optimized for dual-element
More informationZMOTION Lens and Pyroelectric Sensor
ZMOTION Lens and Pyroelectric Sensor PS028609-0213 Copyright 2013 Zilog, Inc. All rights reserved. www.zilog.com ii Warning: DO NOT USE THIS PRODUCT IN LIFE SUPPORT SYSTEMS. LIFE SUPPORT POLICY ZILOG'S
More informationZilog s ZMOTION Detection and Control Family. Featuring PIR Technology
S MOTION CONTROL AND LIGHTING SOLUTIONS Zilog s ZMOTION Detection and Control Family PB022504-0112 ZMOTION DETECTION & CONTROL FAMILY ADVANTAGES MCU, PIR SENSOR, AND LENS SOLUTION MOTION DETECTION ALGORITHMS
More informationPyroelectric Infrared Sensor
Pyroelectric Infrared Sensor The pyrosensor, as developed and supplied to the market by NICERA, is being used world wide for many applications. For example, light switch control, visitor acknowledgement,
More informationD-TECT Dual Tech. GJD360 Triple Technology External Detector
D-TECT Dual Tech GJD360 Triple Technology External Detector PACKAGE CONTENTS 1 x Dual Tech 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2
More informationdesign line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind
design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind Peace of mind The Guardall sensor range comprises two series of motion sensors intended for use in
More informationSensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors
Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Excellent S/N Low voltage operation available Applications Intrusion Detectors Lighting Automation Please
More informationKwêBeams Effective wire free outdoor early warning system
1 KwêBeams Effective wire free outdoor early warning system Features: - Easy to install & use - Operates on 868Mhz frequency (less congested to avoid signal jamming) - All sensors with built in sirens,
More informationD-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit
D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2
More informationDHM5150 Human Motion Sensor Module User Manual
DHM5150 Human Motion Sensor Module User Manual Version: 1.0.2 February 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Running as Part of WiRobot System 3 II.3.
More informationMovement Detector GJD 300
Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before
More informationD-Tect 2 GJD300 Quad PIR Movement Detector
D-Tect GJD0 Quad PIR Movement Detector Package Contents 3. Package Contains: x D-Tect x Drilling template for fixing holes x Allen Key 3 x 3.75mm wall plugs 3 x 3.75mm screws x Spare Sliding Curtains x
More informationLUX Hardwired - Installation Notes
Ness LUX wired PIR with Nightlight Quad element pyro sensor 15m x 15m wide angle coverage Look down Creep Zone Selectable Standard and Pet Aware modes Adjustable sensor mask for No Creep and Pet modes
More informationData Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens
Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Excellent S/N Low voltage operation available Applications Intrusion Detectors Lighting Automation Please
More informationD-TECT 2 IP. GJD230 IP Motion Detector
D-TECT 2 IP GJD230 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 2 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper
More informationInstallation Instructions
HB-15NB High Bay Line Voltage Passive Infrared Occupancy Sensors with Nipple Backbox SPECIFICATIONS HB-15NB Power Module Voltages.............................12/277VAC, 6Hz Load Requirements @ 12VAC, 6Hz.............-8W
More informationDescription. Optex Incorporated
Optex Incorporated Description 1845 W. 205 th St. Torrance, CA 90501-1510 USA TEL (310) 533-1500 and (800) 966-7839 FAX (310) 533-5910 Doc: Model: Desc: Architect/ Engineer Specifications CX-502 PIR Intrusion
More informationD-TECT 3 IP. GJD260 IP Motion Detector
D-TECT 3 IP GJD260 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 3 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper
More informationZMOTION Pyroelectric Sensors
ZMOTION Pyroelectric Sensors PS033601-1214 Copyright 2014 Zilog, Inc. All rights reserved. www.zilog.com ii Warning: DO NOT USE THIS PRODUCT IN LIFE SUPPORT SYSTEMS. LIFE SUPPORT POLICY ZILOG'S PRODUCTS
More informationMovement-based energy control
04 Movement-based energy control 94 International catalogue 2015 4.1 Microwave-based movement sensors 4.2 PIR-based movement sensors 4.2.1 Ceiling-mount 4.2.2 Wall-mount 4.3 Twilight switches 4.4 LED lights
More informationPyroelectric Infrared Sensor PIR
Pyroelectric Infrared Sensor PIR Infrared radiation is the electromagnetic waves in the wavelength region longer than the visible light wavelengths, lying from 0.75 μm to 1000 μm. The wavelength region
More informationOccupancy Sensor LS Descriptions. Product Profile. Technical Specifications
LS-818-3 Descriptions Temco s Passive Infrared Occupancy Sensor is a low cost comercial and residential surface mount occupancy sensor. Advanced filtering reduces false triggering due to air movement and
More informationDT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage
DT00 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS Impressive Performance, Impressive Coverage DT00 Series Sensors Building on more than 20 years of dual technology innovation,
More informationMotion Detector. Installation and Usage Guide. Need help? Visit protectamerica.com/chat
Motion Detector Installation and Usage Guide The Motion Detector guards against intruders moving through your home, providing an additional layer of protection that is especially suited to guarding wide
More informationDetector Application Notes
Detector Application Notes August 2001 1 CONTENTS 1; Installation Guidelines 1.1 Space Detection (PIR) 3 2. General applications: 2.1. Homes/Offices/Shops 4 2.2. Museums 5 2.3. Office Foyers 6 2.4. Long
More informationPassive Infrared Motion Detector 5420/90P. Installation Instructions
Passive Infrared Motion Detector Installation Instructions 5420/90P The 5420/90P Passive Infrared Motion Detector provides reliable, high performance detection at an affordable price. The Detector features
More informationMotion Detectors. Whatever the application, there s a Paradox motion detector that will suit your needs and surpass your expectations.
From outdoor and pet-friendly digital motion detectors to analog motion detectors, the Paradox series of motion detectors combine advanced features and patented technologies to provide a high level of
More information5800-OD Wireless Outdoor Motion Sensor Installation Instructions
GENERAL INFORMATION The Honeywell 5800-OD Wireless Outdoor Motion Sensor (referred to as the 5800-OD) combines the convenience of wireless technology with a full featured outdoor PIR motion sensor. The
More informationHILLS RELIANCE 4 ALARM SYSTEM 4 zone panel
HILLS RELIANCE SERIES Each alarm kit as referenced states maximum recommended zone capabilities. Each zone represents 1 single device 3 detectors = 3 zones 3 detectors + 2 reed switches = 5 zones When
More informationPyroelectric Infrared Radial Sensor
Pyroelectric Infrared Radial Sensor TYPE: S16-L201D NANYANG SENBA OPTICAL AND ELECTRONIC CO.,LTD. Page 1 of 9 Mini SMD Digital Pyroelectric Infrared Sensor The product is a digital intelligent PIR sensor.
More informationLPCMPIRM65 & LPCMPIRDSI65
Product Guide LPCMPIRM65 & LPCMPIRDSI65 Luminaire high mount PIR detectors Overview The LPCMPIR PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual
More informationPSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor
TECHNICAL SPECIFICATIONS PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor Overview Quad Element PIR sensor 0-10V configurable output: set to 0% (OFF)*, 10%, 25% or 50% dimming Photocell for ambient light
More informationPyroelectric Infrared Sensors
Pyroelectric Infrared Sensors Cat.No.S21E-7 for EU RoHS Compliant All the products on this catalog are complied with EU RoHS. EU RoHS is "the European Directive 2002/95/EC on the Restriction of the Use
More informationEWP2WIRELESS MOTION DETECTOR
EN EWP2WIRELESS MOTION DETECTOR User manual v1.2 Compatible with: ESIM364 v02.08.00 and up. EPIR3 v1.2.0 and up EPIR2 v01.03.02 and up Main features: Built-in dual element passive infrared (PIR) sensor.
More informationPIR-100B User Manual
Wireless Passive Infrared Motion Detector PIR-100B User Manual Ver 1.00 Date Issued: 2010-06-08 All rights reserved by King Pigeon Hi-Tech. Co., Ltd. Website: Http://www.GSMalarmsystem.com Table of Contents
More informationOccupancy Sensor LS Descriptions. Product Profile. Technical Specifications
LS-818-3 Descriptions Temco s Passive Infrared Occupancy Sensor is a low cost comercial and residential surface mount occupancy sensor. Advanced filtering reduces false triggering due to air movement and
More informationPyroelectric Infrared Sensors
Pyroelectric Infrared Sensors Cat.No.S1E-8 for EU RoHS Compliant All the products on this catalog are complied with EU RoHS. EU RoHS is "the European Directive 011/65/EU on the Restriction of the Use of
More informationAdvanced DIGITAL Wired PIR Motion Detector
PRELIMINARY Advanced DIGITAL Wired PIR Motion Detector The PIRfect PYR-2021 provides DIGITAL Passive Infra Red (PIR) motion detection across a volumetric area, with versatile advanced SPHERICAL SEALED
More informationPARVIS Safe and tranquil thanks to Parvis
PARVIS Safe and tranquil thanks to Parvis PARVIS MES 9000S PARVIS DUAL PARVIS WS PARVIS SMA A safety system for outdoors, for civil and industrial environments, nts, that integrates e with the garden lighting
More informationMounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.
Installation Guide High-Bay PIR Presence/Absence Detector (317) The 317 High-Bay PIR Presence/Absence Detector, in conjunction with a Helvar lighting control system, provides automatic control of lighting
More informationSYSTEMS GROUP. May Zilog and EE-SGI Present. epir TM. The Next Generation of PIR Motion Detector Technology. (Over View)
May 2008 Zilog and EE-SGI Present epir TM The Next Generation of PIR Motion Detector Technology (Over View) 1 The epir TM Statement epir TM is a revolutionary technology used for passive infrared (PIR)
More informationExtended Range DUAL TEC Motion Sensor
DT-900 S E R I E S Extended Range DUAL TEC Motion Sensor Building on more than 1 of dual technology innovation, IntelliSense s new generation DUAL TEC DT-900 motion sensor provides the features and technology
More informationSECURITY PRODUCTS CATALOGUE
I N T E R N A T I O N A L E D I T I O N SECURITY PRODUCTS CATALOGUE Y O U R S E C U R E C H O I C E SWAN TM SERIES SERIES QUAD IMAGING PET IMMUNE DETECTORS QUAD IMAGING TECHNOLOGY WITH PET IMMUNITY The
More informationM O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of
M O T I O N DETECTORS The Paradox series of motion detectors combines advanced features and patented technologies to provide a high level of detection and false alarm prevention. Whatever the application,
More informationINTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors
INTERNAL DETECTORS Wired and two-way wireless grade 2 and 3 internal detectors An extensive range of internal detectors utilising the latest Pyronix patented technologies for residential, commercial and
More informationLS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors
Datasheet Ceiling mount occupancy sensors Overview The CM Series of ceiling mount occupancy sensors provide a range sensor solutions for applications with finished ceilings (e.g., ceiling tiles, sheetrock,
More informationSystem 2000 System 2000 automatic control switch Safety instructions. 2 Device components
pure white Order-No. : 2270 02 colour aluminium Order-No. : 2270 04 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure
More informationActive Infrared Multi Beam Sensors. R Series
Active Infrared Multi Beam Sensors R Series TECHNICAL MANUAL INDEX GENERAL SAFETY RECOMMENDATIONS 3 CONFORMITY 4 WARRANTY 4 INTRODUCTION 5 FEATURES 5 OPERATIONAL RANGE 6 SETUP TRANSMITTER (TX) 6 SETUP
More informationHeimdall Radar Traffic Detector
Heimdall Radar Traffic Detector Standard VA Detector Installation Guide Document Authorisation Role Name Function Signed Prepared by: R. Martin Project Support Manager Reviewed by: A. Rhodes Lead Product
More information>WIRELESS> ALARM SYSTEM CR200
intrusion >WIRELESS> ALARM SYSTEM CR200 INTRUSION HOME SECURITY CR200 is a Modern, Effective and Versatile 20-zone Household Security System. It is packed with simple Plug & Play functionality, designed
More informationG Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by.
1 1. VZ series Horizontally wide detection type (170μA / Analog output ) 2.Model Number Lens Color White Black Pearl White 3.Dimensions Top VIEW Side VIEW Bottom VIEW Model Number EKMC2605111K EKMC2605112K
More informationUNITY CEILING RECESSED MOUNT CM1900 CM1901 CM1906 CM1912
UNITY CEILING RECESSED MOUNT CM1900 CM1901 CM1906 CM1912 Drawing: 762000XX Rev: A Sheet: 1 of 8 Eng: CLD Date Drawn: 04/21/17 TYPICAL GRID CEILING RECESSED FIXTURE MOUNTING SUPPORT WIRE HOUSING SLOT #8
More informationHeimdall Radar Traffic Detector
Heimdall Radar Traffic Detector Single Lane VA Detector Installation Guide Document Authorisation Role Name Function Signed Prepared by: R. Martin Project Support Manager Reviewed by: A. Rhodes Lead Product
More informationNEMA Guide Publication WD Occupancy Motion Sensors
NEMA Guide Publication WD 7-2000 Occupancy Motion Sensors Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn, Virginia 22209 Copyright 2000 by National Electrical Manufacturers
More informationG Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.
1 1. VZ series Slight motion detection type (170μA / Analog output) 2.Model Number Lens Color White Black Pearl White Model Number EKMC2691111K EKMC2691112K EKMC2691113K Marking 3.Dimensions Top VIEW G745
More informationHomepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS
Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS SENSORS FOR X-AIRCONTROL ZONE MODULES AND OTHER EQUIPMENT Components for the measurement and
More informationl High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.
GENERAL INFORMATION: The No. 1852 provides 12 zones of coverage with a range of up to 25 feet (at a typical mounting height of 7-0 ). This model has the following important features: l High precision,
More informationPIR Occupancy & Motion Sensor
PIR Occupancy & Motion Sensor MOS-17C energy conservation - home and office Overview The MOS-17C is a wireless, energy harvesting, ceiling mount, Passive InfraRed (PIR) occupancy sensor. Used for indoor
More informationCommercial Series TriTech Motion Detector. Reference Guide
Commercial Series riech Motion Detector en Reference Guide Commercial Series riech Motion Detector able of contents en 3 able of contents 1 Safety 4 Introduction 5.1 About documentation 5. Bosch Security
More information"Pegaso" wireless alarm system
"Pegaso" wireless alarm system Summary Page 1.0. Description... 2 2.0. Installation... 3 3.0. Connections to mains power... 4 4.0. Low battery signalling... 4 5.0. Service key... 5 6.0. Selection of functions...
More informationFR-A180 FR-A360. Occupancy detector. Use
5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable
More informationUsing Motion Sensor for Auto Controlling Air Conditioner s Temperature
Using Motion Sensor for Auto Controlling Air Conditioner s Temperature Jurike V Moniaga Department of Computer Science Bina Nusantara University Jakarta, Indonesia Jurike@binusedu S Liawatimena Department
More informationTechnology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2
Passive Infrared Sensors (PIR) Using a patented fresnel lens which minimizes optical aberrations, each Legrand/Pass & Seymour PIR sensor breaks its coverage area into zones. Upon detecting an infrared
More informationCOMPACT FLAME CONTROLLER CFC 2000
COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationLED HIGH BAY LINEAR HL SERIES
PROJECT NAME: CATALOG NUMBER: NOTES: FIXTURE SCHEDULE: Page: 1 of 7 LED HIGH BAY LINEAR PRODUCT DESCRIPTION: The LED Linear Highbay Series offers leading-edge efficacy and scalability for high ceiling
More informationSmart detection. Interlogix commercial sensors feature the latest technology to deliver advanced detection and accurate, reliable performance.
Smart detection Interlogix commercial sensors feature the latest technology to deliver advanced detection and accurate, reliable performance. Commercial Sensors Advanced sensing technology that delivers
More informationDI601AM Outdoor PIR/AM Detector Installation Sheet
DI601AM Outdoor PIR/AM Detector Installation Sheet EN DE ES FR IT NL PL PT SV Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 TOP Figure 8 Figure 9 TOP Long range 30m section Short/ medium
More informationIntrusion Outdoor Protection Perimeter
Intrusion Outdoor Protection Perimeter Borders Commercial industrial Military base Correctional institution VIP Estates/Residences Communication Airports Warehouses Perimeter Sensors: the ideal solution
More informationCeiling PIR HS presence detector. Product Guide. Overview. Features
Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high
More informationHigh-Density Industrial
Installation Instructions 1 High-Density Industrial Drawers in Shelving BORROUGHS CORPORATION 3002 N. BURDICK STREET * KALAMAZOO, MI 49004-3483 800-748-0227 * FAX: 269-342-4161 Industrial Drawer Installation
More informationElite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data
Elite GJD022 /GJD023 35m External PIR Multi Beam Lens Data The GJD multifunction lens fitted to the GJD Elite detector produces 9 long range beams and 9 medium to short range curtain beams. Movement across
More informationDS160/DS161 Request To Exit PIR sensors Installation Instructions
DS160/DS161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160 is a Passive Infrared Detector (PIR) which is UL Listed as an Access Control Device under the UL 294 Standard.
More informationTable of Contents. Intrusion Detectors... I-1. Intrusion Panels... II-1. Type Index... III-1
Table of Contents Intrusion Detectors... I-1 Overview... I-1 Detection-Technologies... I-1 Security Risk Level Overview... I-2 Internal Motion Detectors... 1-1 Product Overview... 1-1 PIR Internal Motion
More informationTechnical Application Guide
Lighting Control Wireless Occupancy Sensor, Wireless Multi Sensor Technical Application Guide Philips wireless occupancy sensor and multi sensor, which are Interact Ready, mean easy upgrade to a smart
More informationInstruction manual for the Infrared Point Type Flame Detector
Instruction manual for the Infrared Point Type Flame Detector (Model 2RA-P) Contents 1.Features 2.Specification 3.Principles of Operation 4.Control Panel and Field Wiring 5.Recommended Places of Installation
More informationDS160/161 Request To Exit PIR sensors Installation Instructions
DS160/161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for request to exit (REX) interior applications. It is UL Listed
More informationInstructions: Changing Existing Downrod to Longer Downrod (sold separately)
FOR MODEL WITH REMOTE RECEIVER INSIDE CANOPY Disassemble Canopy and Remove Downrod from Canopy 1 Remove the cotter pin and clevis pin from the downrod. canopy To remove canopy, I) loosen (but do not remove)
More informationTechnical data lumina PM
1. Product description Technical data The presence detector is suitable for detecting the movement of humans and animals through their radiant heat. The sensitive 4-element-PIR sensor technology for presence
More informationInfrared Wall Mount Occupancy Sensor
LOS-WI LOS-WI-1 02.01.06 Infrared Wall Mount Occupancy Sensor The LOS-WI wall-mounted passive infrared sensor is used in spaces with pendant fixtures, ceiling fans, or high ceilings (more than 12 feet).
More informationPyroelectric Infrared PIR Motion Sensor Detector ADJ User s Guide
Pyroelectric Infrared PIR Motion Sensor Detector ADJ User s Guide 2004-2009 Sure Electronics Inc. DC-SS502_Ver1.0 Table of Contents Chapter 1. Overview...1 1.1 Preface... 1 1.2 Functions... 1 Chapter 2.
More informationHardwired Alarm Accessories
Hardwired Alarm Accessories Contents Wireless Door Contact for WGAP864 WGAP864WDCV2...3 Wireless PIR Sensor (Pet Immunity) For WGAP864 WGAP864WPIRV2...4 Dual Technology PIR / Microwave Detector ALH-PIRMW...5
More informationCommercial Series TriTech+ Motion Detector with Anti-mask
Commercial Series riech+ Motion Detector with ISC-CDL1-WA15G, ISC-CDL1-WA15G-CHI, ISC-CDL1-WA15H, ISC-CDL1-WA15K, ISC-CDL1-WA1G, ISC-CDL1-WA1G-CHI en Reference Guide Commercial Series riech+ Motion Detector
More informationIncreased safety and reducing energy consumption with the motion control RPI 01
User manual Increased safety and reducing energy consumption with the motion control RPI 01 3 m detection distance to control the illumination and temperature of the glass door merchandise in the most
More informationCONFIGURATION OF THE OPTICALS
Technical manual INDEX 1 MAIN COMPONENT LIST Pag. 3 2 MOUNTING EXAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION SAMPLES Pag. 6 4 CONFIGURATION OF THE OPTICALS Pag. 7 OPTICAL TX Pag. 7 OPTICAL
More informationFlight Crew Reading Lights
Flight Crew Reading Lights Best Light for a Challenging Workplace Various functions support flight crew The cockpit represents the most challenging working environment of the entire plane. Operating the
More informationG Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.
1. 2.Model Number VZ series Long distance detection type (170μA / Digital output / High Sensitivity) Lens Color White Black Pearl White Model Number EKMC4603111K EKMC4603112K EKMC4603113K Marking 1 3.Dimensions
More informationHigh performance general illumination
LED Dome Lights High performance general illumination In addition to general ceiling and side wall illumination, there is a need for further lights in parts of the aircraft. LED dome lights from UTC Aerospace
More informationVirtual Boundary System Using Passive Infrared Sensor
International Journal of Education and Science Research Review E-ISSN 2348-6457 Volume-3, Issue-2 April- 2016 Virtual Boundary System Using Passive Infrared Sensor Saptarshi Gupta Assistant Professor SRM
More informationFor a Healthier, Cleaner and Safer Tomorrow. Infrared Sensing. For Secure Homes, Healthier Families and Energy Savings
For a Healthier, Cleaner and Safer Tomorrow. Infrared Sensing For Secure Homes, Healthier Families and Energy Savings Infrared Sensing Technologies For a Healthier, Cleaner and Safer Tomorrow. Excelitas
More informationADPRO PRO Series by Xtralis
ADPRO PRO Series by Xtralis Passive Infrared Outdoor Detectors Product Highlights The ADPRO PRO Series by Xtralis PIR detectors are specifi cally designated for intrusion detection Designed and manufactured
More informationWHAT S IN THE BOX? The IQ Panel also includes a snap on table stand and power supply with cable.
WHAT S IN THE BOX? The IQ Panel 2 keeps you connected to an entire ecosystem of smart devices giving you control over your entire home. Exciting features like touchless disarming using Bluetooth and a
More informationS P A C E D E T E C T I O N
SPACE DETECTION INNOVATIVE SOLTIONS FOR REAL-WORLD PROBLEMS Since our founding in 1977, Sentrol has advanced the security and lifesafety industry by continually producing innovative solutions for real-world
More informationGJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL
GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL A WIRELESS PASSIVE INFRARED DETECTOR AND THREE CHANNEL RECEIVER THAT SIMULTANEOUSLY OR INDIVIDUALLY CONTROLS CCTV SWITCHERS, VIDEO RECORDERS
More informationWIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200
aod-200_en 05/16 WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. +48 58 320 94 00 www.satel.eu Firmware version 1.0 WARNING The device
More informationIntrusion. Outdoor protection perimeter
Intrusion Outdoor protection perimeter Airports Warehouses Military bases Commercial industrial VIP estates/residences Communications Quicker and earlier responses to intrusion events help avoid damages
More informationCS1200 WHT Pir Ceiling Mount Occupancy Sensor
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Area Coverage Field of View Load Type
More informationDS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector
DS970-BEL EN Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector DS970-BEL Installation Instructions.0 Installation Considerations.0 Installation Considerations Not suitable
More informationEnglish. Series. Installation and Use Manual
English Series FOSTER Installation and Use Manual FOSTER Rev.13 03/2015 MITECH srl reserves the right to change the information in this document without warning. Index Anti-intrusion barrier 3 Main components
More informationHEAT EXCHANGE INSTITUTE, INC.
HEAT EXCHANGE INSTITUTE, INC. STANDARDS for STEAM SURFACE CONDENSERS ELEVENTH EDITION Copyright October 2012 by Heat Exchange Institute 1300 Sumner Avenue Cleveland, Ohio 44115-2851 Reproduction of any
More informationProximity Sensors and Motion Detectors
1 Proximity Sensors and Motion Detectors Thomas Schlebusch Abstract In this paper I will present the principles of proximity and motion detectors. First I will give an overview about the physical variables
More information