Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Size: px
Start display at page:

Download "Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM"

Transcription

1 Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND +44 (0)

2 Document Revision Details Issue Modification Detail Author Date 2 Removed technical specifications PD 25/10/ Revision of images Revision of testing section 2 NS 09/12/ Updated screenshots PD 14/09/ Revision of images Group sections 13.7 &13.8 updated Weekly Test section removed CM 11/12/2017 Notice This manual may be revised as a result of enhancements to the system software or hardware. Check for revisions to this manual, and download them, from the website RDM0001/3_2 Page 2 of Protec Fire Detection plc

3 Table of Contents DOCUMENT REVISION DETAILS... 2 INTRODUCTION... 6 PROTEC MANUFACTURED ALGO-TEC 6000 EQUIPMENT 5 YEAR WARRANTY USER RESPONSIBILITIES Requirements of the Premises Management Named Person ROUTINE TESTING OF THE SYSTEM Daily Inspection Weekly Test Monthly Test ACCESS LEVELS Access Level 1 (General User) Access Level 2 (Authorised / Trained User) Access Level 3a (Exchange Loop Devices) INDICATIONS AND CONTROLS LCD (Liquid Crystal Display) General Indications Status Indications Zone Indications FIRE INDICATIONS General Fire Indicator Illuminated Zone Indicator Flashing Red FAULT INDICATIONS System Fault Alarm Fault Power Fault Aux. Supply Fault Network Fault Fire link Fault Fire Protection Fault DISABLEMENT INDICATIONS Alarms Disabled Alarm Routing (Fire link) Disabled Fire Protection Disabled OTHER INDICATIONS Power Test Alarm Routing (Fire Link) Operated Fire Protection Operated RDM0001/3_2 Page 3 of Protec Fire Detection plc

4 8.5 Outputs Delayed SYSTEM DELAYS COINCIDENCE/DEPENDENCY OPERATION RESPONSE TO AN ALARM Automatic Detection Manual Detection Coincidence/Dependency Activation Silencing the Alarms Resetting the panel after an Alarm New Zone in Alarm Activating the Alarms Manually STATUS DISPLAY & MENU NAVIGATION The System Normal Display Navigating the menus Printing Panel Selection Card Selection Loop Selection Device Selection Login The Fault, Disablement and Test Display The Fire Alarm Display USER MENUS Entering the Menu System System View Device Detail Algo-Tec Data Panel Summary Device State Input Groups Output Groups Disable / Enable Current Disablements Zone Disablements Device Disablement Output Group Disablement Output Disablement Disable all fire Links Disable all fault Links Disable all fire protection outputs Disable all alarm outputs Disable all control outputs Disable all non-fire outputs Settings Set Time / Date RDM0001/3_2 Page 4 of Protec Fire Detection plc

5 13.23 Show Configuration Clear System Fault Software Versions Test Menu Lamp / Buzzer Test Zone Test Test Options Complete System Test History View all fires View all non-fires View by type Historic Alarm Count Printer Menu EXCHANGING LOOP DEVICES Entering the Level 3a Main Menu Tools menu Loop Tools Exchange Device Menu APPENDIX A, RVAV DESCRIPTION STANDARDS, DIRECTIVES AND REGULATIONS INFORMATION RDM0001/3_2 Page 5 of Protec Fire Detection plc

6 Introduction This manual applies to the Protec 6500 and 6600 fire alarm control panels however for convenience; reference will be made only to the Everything in this manual applies to both the 6500 and 6600 unless stated otherwise. The Protec 6500 Fire Alarm Control Panel has been designed and manufactured in the United Kingdom and complies fully with the latest standards dictating fire alarm system design practice (EN54-2: A1:2006 and EN54-4: A1: A2:2006). The 6500 is a multi-zone four loop fire alarm control panel that uses digital addressable technology to communicate with Protec 6000PLUS series loop devices (automatic detectors, Manual Call Points, sounders, interfaces etc.). Multiple panels may be networked together to create a larger fire alarm system. As the integrity and reliability of a fire alarm system is vital, the system continuously monitors all critical paths for faults. The fire detection / alarm loop devices and wiring are constantly monitored to check for faults. The integrated power supply regularly performs self-checking to ensure it is in full working order and that the Stand-by batteries are in a good state. Any faults detected are reported on the front panel display, a fault output is also provided which may be connected to external systems (a remote monitoring centre, for example) to signal that the system has a fault and attention is required. The panel is wall mounted either flush or surface and the generously sized back box allows ample space for rear or top cable entries. This equipment and its associated connections must be installed, commissioned and maintained by a suitably trained skilled and competent person. This equipment is not guaranteed unless installed and commissioned in accordance with current national standards There are no user serviceable parts inside the A competent person trained to undertake such work MUST carry out any internal maintenance work. Separate installation and commissioning manuals are available. RDM0001/3_2 Page 6 of Protec Fire Detection plc

7 Protec Manufactured Algo-Tec 6000 Equipment 5 year warranty To demonstrate confidence in our product, we provide an extended warranty on our Protec manufactured Algo-Tec TM 6000 equipment. When a Protec maintenance contract is in place, we warrant all the Protec Algo-Tec TM 6000 equipment we manufacture for 5 years. If, during a service visit, the Protec Service Engineer suspects any Protec manufactured Algo-Tec TM 6000 devices are not working properly, they will be replaced at no cost to the client. Similarly, during the course of a call out, any suspect devices will be replaced at no cost, with only the normal labour and travelling time charged at standard agreed rates. Contact Protec Fire Detection for details. Note that Algo-Tec Equipment incorporating a CO sensor is excluded from the warranty. RDM0001/3_2 Page 7 of Protec Fire Detection plc

8 1.0 User Responsibilities The registered owner of the fire alarm system has specific responsibilities regarding the installation, testing and maintenance of the fire alarm system. BS5839 Pt 1: 2017 Section 6 states that the user of the fire alarm system must appoint a single named person to supervise all matters regarding the fire alarm system. Summarised below are the responsibilities expected of the named person, It is strongly advised that a full copy of BS5839 Pt 1: 2017 is obtained and thoroughly read and understood. 1.1 Requirements of the Premises Management Named Person Ensure that the fire alarm equipment is checked at least once every 24 hours to ensure there are no faults on the system. Report any faults to the site maintenance manager. Ensure that arrangements are in place for correct testing of the fire alarm system (as specified in BS5839 Pt 1: 2017 Section 6, the user testing is summarised in section 2.0 of this document). Ensure that the system event log is kept up to date and is available for inspection by any authorised person when required. Ensure that all occupants of the protected premises are trained how to use the system properly and that they are aware of what action to take in the event of an alarm. Ensure that false alarms are minimised. Ensure all detectors and manual call points are not obstructed. Detectors must have at least 500mm clear space preserved in all directions around them. Establish a liaison with those responsible for changes in, or maintenance of the building fabric. Ensure that when changes are made to the system, record drawings and operating instructions are updated. Ensure that, where necessary, a suitable zone plan is displayed and kept up to date. Ensure that any relevant spare parts for system maintenance are held within the premises. RDM0001/3_2 Page 8 of Protec Fire Detection plc

9 2.0 Routine Testing of the System Recommendations for testing of the system are detailed in BS5839 Pt 1: 2017 (Section 6) The routine testing is briefly detailed below. 2.1 Daily Inspection Check that the Power indicator is illuminated. Check for any faults on the system and report these to the site maintenance manager. 2.2 Weekly Test Perform the daily test recommended in 2.1 and; During the test you may wish to temporarily place the zone to be tested into test mode (Consult section 13) Perform an indicator test (lamp test) to check the integrity of the front panel indications, and internal buzzer. Ensure no Manual Call Points or detectors are obstructed. Operate a Manual Call Point or detector during normal working hours to ensure the fire alarm system operates correctly. A different Manual Call Point or detector on a different zone should be tested each week, in this way all the devices on all the zones are tested. Ensure the system sounders are operational. Ensure the sounders are not operated for longer than 30 seconds during testing. The occupants of the building can then distinguish genuine alarms. 2.3 Monthly Test Perform the weekly test recommended in 2.2 and; If an automatic generator is used as part of the mains failure back-up system it should be started up once each month by simulated failure of the normal power supply, and then run in this mode for at least 1 hour. Visually inspect the stand-by batteries and their connections. Check that the batteries are capable of supplying the alarm sounders. Note:- Care is necessary to ensure that any person undertaking these tasks is competent to do so safely and has the relevent technical knowledge and training RDM0001/3_2 Page 9 of Protec Fire Detection plc

10 3.0 Access Levels There are three access levels to allow users of different authorisation levels access to various parts of the system. The access levels and a description of functions available are given in the next sections. 3.1 Access Level 1 (General User) Access level 1 allows the general user to view the status of the panel at any time. Zone fire, fault, disablement and test states are clearly displayed as are any current system faults and disablements. Full detail of the front panel display is given in the next section. The following functions may be performed at access level 1. Entering code for access level 2 or 3a Viewing current fires Viewing current faults Viewing current disablements Viewing current tests Accepting current faults or alarms ( Mute Buzzer ) Accepting at access level 1 is only available if the button has been made available during the commissioning stage 3.2 Access Level 2 (Authorised / Trained User) Access level 2 allows the authorised user access to various critical system functions. To enter access level 2 enter the user code using the touchscreen LCD (section 12.8). Refer to section 13 for the features accessible at access level Access Level 3a (Exchange Loop Devices) Access level 3a allows the maintenance staff access to the loop device exchange function. To enter access level 3a enter the level 3a code using the touchscreen LCD (section 12.8). Refer to sections 13 & 14 for the features accessible at access level 3a. RDM0001/3_2 Page 10 of Protec Fire Detection plc

11 4.0 Indications and Controls Each panel has a comprehensive front panel display enabling the current state of the system to be rapidly determined. Figure 5.0 shows the indications and controls. Figure 5.0 Front panel indications and controls. 4.1 LCD (Liquid Crystal Display) The LCD gives a clear indication of the current status of the panel. Under normal conditions the LCD shows the System Normal screen. This screen changes to the status display screen if the panel has fires, faults, disablements or tests present. 4.2 General Indications These are the General Fire, Fault, Disablement and Test indicators. These give clear indication that the panel has at least one Fire, Fault, Disablement or Test condition. It is possible for the panel to indicate multiple conditions simultaneously. 4.3 Status Indications These provide important fault and status information at a glance without having to search for it on the LCD. 4.4 Zone Indications The zone in fire is always indicated on the LCD however if the fire occurs in one of the first 100 zones (40 zones on a standalone panel) then it is also indicated by the zone indicator flashing red. If the user touches Accept then the zone indicator will remain on but stop flashing. RDM0001/3_2 Page 11 of Protec Fire Detection plc

12 5.0 Fire Indications The panel displays fire information on the LCD along with the General Fire indicator and the relevant zone indicators. The following sections detail the meaning of each indicator. 5.1 General Fire Indicator Illuminated The panel has detected a fire on one of its zones, or has been activated from another panel via the network. The building fire plan should be executed immediately 5.2 Zone Indicator Flashing Red The panel has detected a fire in the zone shown. The General Fire indicator will always accompany this and the internal buzzer will be fast pulsing. RDM0001/3_2 Page 12 of Protec Fire Detection plc

13 6.0 Fault Indications When the panel has detected a fault in any of the critical operating paths of the system it will display this on the LCD. The internal buzzer will also pulse slowly. The General Fault indicator will be illuminated and is always accompanied by other indicator(s) detailing the exact fault. In general, fault indicators flash until the fault is accepted (by touching the Accept button) the fault indicator then illuminates steadily and the internal buzzer will be muted. Further faults activate the buzzer again. In the event of any fault the following action should be taken:- Investigate the fault, and then accept the fault by touching the Accept button. Note the fault down in the Logbook and take action to remedy the fault. In all cases expert advice should be sought. When the fault has been rectified the fault indicator will automatically extinguish. Note: - Some faults latch and once rectified must be cleared by pressing Reset. Any faults that have not been fixed will reappear. The following sections give descriptions of each fault indication 6.1 System Fault The panel performs regular self-tests to ensure the software is working correctly. If a fault is detected in software operation a System Fault is declared. This is a latching fault and can only be cleared by touching Clear System Fault. If the fault is still present it will then reappear. 6.2 Alarm Fault A fault has been detected on one or more of the alarm devices connected to the loop or on one of the sounder circuits. One or more alarm devices may no longer operate correctly. 6.3 Power Fault A fault has been detected in the panel s power supply. This may be because the local mains supply has failed or because the internal stand-by batteries or circuitry are faulty. 6.4 Aux. Supply Fault A fault has been detected with the Auxiliary 24V supply output of the panel. There may no longer be an auxiliary supply to external devices or the auxiliary devices are drawing too much current. The General Fault indicator will be illuminated accompanied by the Aux Supply Fault indicator. RDM0001/3_2 Page 13 of Protec Fire Detection plc

14 6.5 Network Fault A fault has been detected on the network connecting the panels together. 6.6 Fire link Fault A fault has been detected on the monitored fire link path. This may be a wiring fault or a fire link interface fault. The connection to the fire station link is no longer reliable. Expert advice should be sought immediately. 6.7 Fire Protection Fault A fault has been detected on the monitored path to fire protection equipment. This may be a wiring fault or a fire protection interface fault. The connection to the fire protection equipment is no longer reliable. Expert advice should be sought immediately. RDM0001/3_2 Page 14 of Protec Fire Detection plc

15 7.0 Disablement Indications When a user has disabled a critical feature of the system it will display this on the LCD. The internal buzzer will also pulse slowly. The General Disablement indicator will be illuminated and is always accompanied by other indicator(s) detailing the exact disablement. In general, the buzzer will sound for disablements until the disablement is accepted (by touching the Accept button). Further disablements activate the buzzer again. The following sections give descriptions of each disablement indication 7.1 Alarms Disabled Activation of outputs designated as alarm outputs is prevented. The sounders will not operate in the event of a fire. 7.2 Alarm Routing (Fire link) Disabled Activation and faults on the alarm routing output are inhibited. The fire link will not activate in the event of a fire. 7.3 Fire Protection Disabled Activation and faults on the fire protection equipment output are inhibited. The fire protection equipment output will not activate in the event of a fire. RDM0001/3_2 Page 15 of Protec Fire Detection plc

16 8.0 Other Indications 8.1 Power 8.2 Test This indication illuminates when the panel is powered up from mains or batteries. This indication illuminates when part or the whole of the panel is in test mode. 8.3 Alarm Routing (Fire Link) Operated This indication is illuminated when the fire link path has been activated on this panel. This does not confirm that the fire event has been sent to a remote monitoring centre unless the confirmation input option has been programmed and the receiving equipment supports this confirmation feature. 8.4 Fire Protection Operated This indication is illuminated when the fire protection equipment path has been activated. This does not confirm that the fire event has been sent to the fire protection equipment unless the confirmation input option has been programmed and the receiving equipment supports this confirmation feature. 8.5 Outputs Delayed This indicator will be illuminated if the commissioning engineer has programmed the system in a manner that will delay the alarm outputs, the fire link activation or the fire protection equipment output if the system detects a fire signal. The alarms, fire link or fire protection equipment output may not activate immediately in the event of a fire. RDM0001/3_2 Page 16 of Protec Fire Detection plc

17 9.0 System Delays Delays may have been programmed into the panel at commissioning time to allow a predetermined delay time from a zone activation until:- The alarm outputs activate The fire link activates The fire protection equipment output activates Delays may be used in order to allow time for the cause of the activation to be investigated by the premises management. If the cause of the activation is found to be legitimate the alarm outputs can be manually activated. If the cause of the activation is found to be false the system can be silenced and reset. The system set-up chart must be consulted to determine exactly which outputs have been delayed, how the delay time has been set up and what action is taken if the Silence button is touched before a delay has expired. In general, delays only apply to automatic detector activations whilst a manual activation on a zone (Activating a Manual Call Point) overrides delays. RDM0001/3_2 Page 17 of Protec Fire Detection plc

18 10.0 Coincidence/Dependency Operation At the time of commissioning, the system may have been programmed to operate in one of three coincidence modes where a confirmation signal is required. The confirmation signal is normally the same or a second device generating a fire signal. Mode C is the standard coincidence mode used in Protec fire alarm systems. Coincidence operation is used to minimise the effects of false alarms by providing time to investigate the first fire signal and if found to be an unwanted activation, prevent a full evacuation of the premises and an unnecessary call to the fire brigade. Mode A, also known as Dependency/Coincidence Type A indicates the zone in alarm and sounds the panel buzzer, however it does not light the general fire led and activate the outputs unless there is a confirmation signal from the same device or an automatic device in the same zone. Mode B, also known as Dependency/Coincidence Type B indicates the zone in alarm and sounds the panel buzzer, however it does not light the general fire led and activate the outputs unless there is a confirmation signal from the same device or an automatic device in any zone. Mode C, also known as Coincidence/Dependency Type C indicates the fire alarm as normal but does not activate any outputs until there is a confirmation signal from another device (manual or automatic) in any zone or a programmed timeout expires. In general, coincidence only applies to automatic detector activations whilst a manual activation on a zone (Activating a Manual Call Point) overrides coincidence. RDM0001/3_2 Page 18 of Protec Fire Detection plc

19 11.0 Response to an Alarm 11.1 Automatic Detection If a detector (smoke, heat etc.) activates in a zone of the panel this is known as an automatic activation. The panel responds by; Illuminating the General Fire indicator. Flashing the relevant zone fire indicator and displaying on the LCD. Fast pulsing of the internal buzzer. Activating alarm outputs as programmed, after any delays have expired. Activating the Fire Link output after any programmed delays have expired. Activating the Fire Protection equipment output after any programmed delays have expired Manual Detection If a Manual Call Point is operated in the zone of a panel this is known as manual activation. The panel responds by; Illuminating the General Fire indicator. Flashing the relevant zone fire indicator and displaying on the LCD. Fast pulsing of the internal buzzer. Activating alarm outputs as programmed, after any delays have expired. Activating the Fire Link output after any programmed delays have expired. Activating the Fire Protection equipment output after any programmed delays have expired. It is usual to have no programmed delay for a manual activation Coincidence/Dependency Activation Please see section Silencing the Alarms Touching and holding Silence when logged in will silence the alarm outputs Resetting the panel after an Alarm After the cause of the alarm has been determined (and entered in the log by the authorised user) the panel can be reset if required. Manual Call Points, if triggered, must first be reset locally. When logged in, touch and hold reset. The panel will reset any latched devices on its loops. The Reset sequence takes about 20 seconds during which time the panel will not detect new fires. RDM0001/3_2 Page 19 of Protec Fire Detection plc

20 11.6 New Zone in Alarm If a new zone or a previously silenced zone goes into alarm, the panel will re-activate the alarms and re-sound the internal buzzer Activating the Alarms Manually Touch and hold Sound Alarms when logged in to evacuate the building. Output group types will be activated as programmed but the Control and Fire Link outputs WILL NOT be activated. If the sound alarms input is set to operate a fire link output this will create a design error. RDM0001/3_2 Page 20 of Protec Fire Detection plc

21 12.0 Status Display & Menu Navigation At any given time the system will be in one of three main states. These are the normal state, the fault / disablement / test state or the fire state The System Normal Display When the system does not have any fires, faults, disablements or tests it is in the System Normal state. In this state the panel will have its power on indicator illuminated and the LCD will show the System Normal display, as shown below:- Touch the centre of the screen to display the code entry screen, refer to section RDM0001/3_2 Page 21 of Protec Fire Detection plc

22 12.2 Navigating the menus Touching the up arrow scrolls up a menu list. If already at the top of the list then a touch of this button wraps round to the bottom of the menu list. Touching the down arrow button scrolls down a menu list. If already at the bottom of the list then a touch of this button wraps round to the top of the menu list. Some menu options require a number of steps to select from a menu list. To avoid having to exit then go through the whole process again, touching this arrow selects the previous item in the menu list. This button will eventually wrap round from the top of the list to the bottom. Some menu options require a number of steps to select from a menu list. To avoid having to exit then go through the whole process again, touching this arrow selects the next item in the menu list. This button will eventually wrap round from the bottom of the list to the top. To leave any menu, touch the EXIT button. As a security measure the panel will exit the menus automatically if no key activity has been detected for 30 minutes. RDM0001/3_2 Page 22 of Protec Fire Detection plc

23 12.3 Number entry Some menu lists contain many lines. To speed up the search through a list, touch the Keypad button (if available) to display a keypad. Enter a menu item number then press Enter to move directly to that menu number position in the list. The keypad for the zone list is shown below :- Similar keypads are used to enter other menu information such as dates Touch Cancel to exit the keypad menu Touch Enter to accept the entered number 12.4 Printing If the panel has a printer fitted then some menus will offer the option to print. Touch the button to print the information RDM0001/3_2 Page 23 of Protec Fire Detection plc

24 12.5 Panel Selection Many menu options start by requiring the user to select a panel. If the system comprises a single panel then this screen is not required. Navigate the list to find the correct panel then touch to select it. During commissioning of the system, the panels can be assigned text relevant to their location to assist in finding the appropriate one Card Selection Each panel comprises a number of cards. Once the user has selected a panel then the list of relevant cards is presented. If searching for a loop device, touch to select the correct loop card. RDM0001/3_2 Page 24 of Protec Fire Detection plc

25 12.7 Loop Selection Each loop card has two loops. Touch to select the correct loop. During commissioning of the system, the loops can be assigned text relevant to their location to assist in finding the appropriate one. Note :- A loop with 000 devices may not be selected 12.8 Device Selection Each loop comprises up to 200 devices. Search the list for the correct device then touch to select it. Note :- Only addresses with a device assigned will be displayed. RDM0001/3_2 Page 25 of Protec Fire Detection plc

26 12.9 Login If the Login button is not displayed then touch the centre of the screen to Login, refer to section 12.1 Access to the features of the panel is achieved by logging in. Press Login and the display will show :- Enter the user code by touching the relevant number buttons then touch Enter. If the code is correct then the display will show the User main menu screen see section 13, or the Level 3a main menu screen see section 14 Touching the Service Info button will display contact details of the company responsible for servicing your system. RDM0001/3_2 Page 26 of Protec Fire Detection plc

27 12.10 The Fault, Disablement and Test Display If the system has one or more faults, disablements or tests the panel will display this as shown below Faults, disablements and tests are always accompanied by the relevant general indicator, Touching the Accept button will mute the panel buzzer. Touching one of the summary buttons will retrieve more detailed information about the individual faults, disablements or tests. The summaries of Disablements, Tests and Other information are displayed in a similar manner to the fault summary below. The Accept button at this level is optional and will only be displayed if configured to do so during the panel commissioning. RDM0001/3_2 Page 27 of Protec Fire Detection plc

28 Touching the Fault summary will display a list of the current faults:- General faults will automatically clear when the cause of the fault is fixed. System faults do not clear automatically but have to be cleared by pressing Clear System Fault, refer to section Touch Reset to clear latching faults such as loop faults. Any faults that have not been fixed will reappear. RDM0001/3_2 Page 28 of Protec Fire Detection plc

29 12.11 The Fire Alarm Display The panel enters the alarm state if one or more loop devices have triggered (this may be because an automatic detector has sensed a fire, or a Manual Call Point has been operated). The panel will activate its alarms as dictated by the system programming once commissioned. The General Fire indicator will illuminate and (if the alarm is in zones 1 to 100) the zone indicator will flash red. Note: - A standalone panel will only illuminate zone indicators 1 to 40 as it only allows 40 zones to be used. The LCD shows the fire display (overriding any normal or fault displays) as shown below The display follows the format of displaying the first zone in fire, latest zone in fire and the total number of zones in fire. Touching Accept will mute the panel buzzer To silence the sounders (section 11.4) and to reset the system (section 11.5) requires the user to login (section 12.8) by pressing the To silence touch here and login button instead of the usual Login button. RDM0001/3_2 Page 29 of Protec Fire Detection plc

30 The user may touch either the first or latest fire to retrieve more detailed information about them. Touching View all fires will display a list of all the current fire events:- The screen automatically returns to the standard fire display if no buttons are touched for 30 seconds. Touching one of the fire events will show details of the fire event:- The screen automatically returns to the standard fire display if no buttons are touched for 30 seconds. RDM0001/3_2 Page 30 of Protec Fire Detection plc

31 13.0 User Menus 13.1 Entering the Menu System When the user code is entered, the User Main Menu screen will be displayed. The Sound Alarms, Silence and Reset buttons are now enabled. The printer menu option is only available on panels configured to have a printer Touch a menu option to select it. System View refer to section 13.2 Disable / Enable refer to section 13.9 Settings refer to section Test Menu refer to section History Menu refer to section RDM0001/3_2 Page 31 of Protec Fire Detection plc

32 13.2 System View Touching System View displays options to show the system configuration. RDM0001/3_2 Page 32 of Protec Fire Detection plc

33 13.3 Device Detail Touching Device Detail displays the list of panels on the system. Select a Panel (section 12.4), Loop Card (section 12.5), Loop (section 12.6) and a Device (section 12.7). Touch Disable to disable the device If the device is already disabled, touch Enable to cancel the device disablement Each device has a serial number. This serial number is associated with an address number by the panel. In order to assist with the location of devices, it is possible to force a device to flash its address details. This process is known as Remote Visual Address Verification (RVAV). Putting a device in RVAV mode prevents it from detecting a fire event. A multiple address device such as a 16 way board loses the ability to detect a fire event from all its 16 addresses. Touch Locate device to instruct the device to flash its address using its LED RDM0001/3_2 Page 33 of Protec Fire Detection plc

34 A device will time out of RVAV mode after 20 minutes however the menu will time out after 30 minutes (Refer to Appendix A for details of the LED flashing) RDM0001/3_2 Page 34 of Protec Fire Detection plc

35 13.4 Algo-Tec Data Algo-Tec Data is only available for detector devices. Touching Algo-Tec Data displays the algorithm data for the device. RDM0001/3_2 Page 35 of Protec Fire Detection plc

36 13.5 Panel Summary Touching Panel Summary displays the list of panels on the system. Select a Panel (section 12.4) to display its loop device summary. RDM0001/3_2 Page 36 of Protec Fire Detection plc

37 13.6 Device State Touch Device State to display the list of panels on the system. Select a Panel (section 12.4), Loop Card (section 12.5) and a Loop (section 12.6). The device state of up to 20 loop devices is displayed at once. Touch a device icon to display the device details. Refer to section 13.3 for the device details screen Press Help for information about the screen Note that indication of Device Pre-Alarm is not currently supported. RDM0001/3_2 Page 37 of Protec Fire Detection plc

38 13.7 Input Groups Touch Input Groups to display the list of input groups and their current state. Note: - The Input Groups Active menu may be blank if no input groups are active. Press View All to view all input groups (Active and Inactive). Press View Active to return to viewing only the active input groups. RDM0001/3_2 Page 38 of Protec Fire Detection plc

39 13.8 Output Groups Touch Output Groups then displays the list of output groups local to the panel and their current state. Note: - The Output Groups Active menu may be blank if no output groups are active. Press View All to view all output groups (Active and Inactive). Press View Active to return to viewing only the active output groups. RDM0001/3_2 Page 39 of Protec Fire Detection plc

40 13.9 Disable / Enable Touching Disable / Enable displays the disablement options. Disabling an input device temporarily prevents it from generating a fire signal or a fault signal. Disabling outputs temporarily prevents them from signalling that the system is in a fire state. A disablement remains in place until the user cancels (normalises) it Current Disablements Touching Current Disablements displays the disablement summary. RDM0001/3_2 Page 40 of Protec Fire Detection plc

41 13.11 Zone Disablements Touching Zone displays the three zone disablement options. Touching any of the option buttons displays the zone list. Touch a normal zone to disable it and the disabled count will increment by one. Touch a Disabled zone to normalise it and the disabled count will decrement by one. The list of zones contains zones, many of which may not be used. The system will allow these unused zones to be disabled however no devices will actually be disabled. Note: - A single panel will only display 40 zones not RDM0001/3_2 Page 41 of Protec Fire Detection plc

42 This indicates that those devices in this zone which were assigned as Manual Class when the panel was commissioned are disabled. This disablement can only be removed in the manual call points zone disablement menu. This indicates that those devices in this zone which were assigned as Automatic Class when the panel was commissioned are disabled. This disablement can only be removed in the automatic detection zone disablement menu. This indicates that all the devices in this zone are disabled. This disablement can only be removed in the all devices zone disablement menu. RDM0001/3_2 Page 42 of Protec Fire Detection plc

43 13.12 Device Disablement Touching Device displays the list of panels on the system. Select a Panel (section 12.4), Loop Card (section 12.5) and a Loop (section 12.6). A list of devices on the loop will be presented. Touch a device address to disable its input, touch it again to normalise it (cancel the disablement). Disabling a device without an input e.g. a sounder, is possible but does not prevent the sounder from activating. RDM0001/3_2 Page 43 of Protec Fire Detection plc

44 13.13 Output Group Disablement Touching Output Group displays the list of panels on the system. Select a Panel (section 12.4). A list of output groups on the panel will be presented. Touch an output group to disable it, touch it again to normalise it (cancel the disablement). Output groups of type Alarm are greyed out because they cannot be disabled. Output groups that are greyed out may be disabled using the panel logic and are usually operated by a keyswitch or invisible switch device. RDM0001/3_2 Page 44 of Protec Fire Detection plc

45 13.14 Output Disablement Touching Output displays the list of output options that can be disabled. Touch a disablement option to disable it, touch it again to normalise it (cancel the disablement). Outputs that are greyed out and listed as unavailable are disabled via the panel logic and are usually operated by a keyswitch or invisible switch device. RDM0001/3_2 Page 45 of Protec Fire Detection plc

46 13.15 Disable all fire Links The fire link is the output used to signal a fire event to a remote monitoring centre Disable all fault Links The fault link is the output used to signal a fault event to a remote monitoring centre Disable all fire protection outputs The fire protection output is the output used to trigger another panel controlling fire protection equipment Disable all alarm outputs Alarm outputs are sounder devices that turn on when there is a fire event and turn off when the system is silenced Disable all control outputs Control outputs are typically interface devices that shutdown plant equipment when there is a fire event. These shutdowns remain in place when the system is silenced and only cancelled when the system is reset Disable all non-fire outputs Non-fire outputs are typically interface devices that do not control equipment when there is a fire event. These outputs are not affected when the system is silenced or reset. RDM0001/3_2 Page 46 of Protec Fire Detection plc

47 13.21 Settings Touching Settings displays the settings menu. RDM0001/3_2 Page 47 of Protec Fire Detection plc

48 13.22 Set Time / Date Touch the Set Time / Date button to adjust the time and date. Note: - The seconds cannot be adjusted. Touch the + button to increment the relevant counter. Touch the button to decrement the relevant counter. Indicates that the panel will NOT update the time to allow for the beginning and end of British Summer Time (Daylight Saving). This function is not currently supported. Indicates that the panel will automatically update the time to allow for the beginning and end of British Summer Time (Daylight Saving). This function is not currently supported. When finished setting both the Time and Date, touch set to save the information. To exit without changing the Time or Date, touch Cancel. RDM0001/3_2 Page 48 of Protec Fire Detection plc

49 13.23 Show Configuration Touch Show Configuration to display the panel s site file configuration information Clear System Fault Touch the Clear System Fault button to remove any system faults. If the cause of the system fault remains then the system fault will reappear. RDM0001/3_2 Page 49 of Protec Fire Detection plc

50 13.25 Software Versions Press Software Versions to display the list of panels on the system. Select a Panel (section 12.4). The panel cards and firmware versions will be displayed Test Menu Touch Test Menu to display the test options. RDM0001/3_2 Page 50 of Protec Fire Detection plc

51 13.27 Lamp / Buzzer Test Touch to test the LCD, panel buzzer and the LED indications. RDM0001/3_2 Page 51 of Protec Fire Detection plc

52 13.28 Zone Test Activations from a zone programmed into test mode will not activate the Fire Link output. Remember to take the zone out of test mode when testing has been completed. Touch Zone Test to select a zone for testing. Note: - It is possible to select and test a Zone that is not used. If a device is activated in a zone under test then only the alarm outputs, including talking sounders, on that panel will be activated (assuming the alarm outputs have been enabled during test see section 13.29). RDM0001/3_2 Page 52 of Protec Fire Detection plc

53 13.29 Test Options Touch Test Options to display the status of each test option. Alarm Outputs During Test In test mode, only alarm outputs, including talking sounder outputs can be activated. If this option is Disabled then no outputs will activate during test fire events. User System Test The feature to allow the user access to the Complete System Test is an option. If this is Disabled then the user is not permitted access to the Complete System Test. Selective Display This feature is an engineer option used to restrict the display of test fire events to a selected panel. Auto Reset / Auto Reset Delay If Auto Reset is Enabled then a test fire event will be automatically reset after a pre-programmed delay. This delay is the Auto Reset Delay time. RDM0001/3_2 Page 53 of Protec Fire Detection plc

54 13.30 Complete System Test Complete System test will put the entire fire system into test mode. During complete system test, the fire link output will not transmit the fire signal to a remote monitoring centre. Remember to take the system out of complete system test mode when testing has been completed. Touch Complete System Test to put the entire fire system into test mode. Touch to cancel the Complete System Test. Note: - When a device is activated in complete test mode, the alarm outputs, including talking sounders, will be activated on all panels (assuming the alarm outputs have been enabled during test see section 13.29). RDM0001/3_2 Page 54 of Protec Fire Detection plc

55 13.31 History Touch History to display the Historic log options View all fires Touch View all fires to view all the fire events from the log. RDM0001/3_2 Page 55 of Protec Fire Detection plc

56 13.33 View all non-fires Touch View all non-fires to view all events from the log except fire events. RDM0001/3_2 Page 56 of Protec Fire Detection plc

57 13.34 View by type Touch View by type to select the type of event to view from the log. The display of events from the log will begin by displaying the most recent events first. Touch Today to begin by displaying today s events. Touch Date to display events since a specific date and time. In the above example, the user has chosen to display events since 8:30 on the 10 th September RDM0001/3_2 Page 57 of Protec Fire Detection plc

58 13.35 Historic Alarm Count Touch Historic Alarm Count to display the current alarm count. The alarm count is a count of the number of times that the panel has entered the fire alarm state since the count was last reset. Note: - The user cannot reset the alarm count. RDM0001/3_2 Page 58 of Protec Fire Detection plc

59 13.36 Printer Menu Touch Printer Menu to access the printer options. Note; - The printer menu option is only available on panels configured to have a printer. Touch to print all current fault events. Touch to print all current disablement events. Touch to print all current test mode events. RDM0001/3_2 Page 59 of Protec Fire Detection plc

60 Touch Loop Device Reports to display the loop device Report options. Touch to print the device analogue values from a selected panel and loop. Touch to print the device isolator number, software version and sensitivity from a selected panel and loop. Touch to power up the printer so that its paper feed sensor is active and a new roll of paper can be installed. Fitting a new roll of paper requires the panel door to be opened possibly exposing high voltage terminals. A competent person trained to undertake such work MUST carry out any internal maintenance work. A competent person trained to undertake such work MUST carry out any internal maintenance work. Touch to print the last one hundred events that the panel has logged. RDM0001/3_2 Page 60 of Protec Fire Detection plc

61 14.0 Exchanging Loop Devices 14.1 Entering the Level 3a Main Menu To login see section When the level 3a code is entered, the Main Menu screen will be displayed. The Sound Alarms, Silence and Reset buttons are now enabled. Touch a menu option to select it. System View refer to section 13.2 Disable / Enable refer to section 13.9 Settings refer to section Test Menu refer to section History Menu refer to section Tools Menu refer to section 14.2 RDM0001/3_2 Page 61 of Protec Fire Detection plc

62 14.2 Tools menu Touching Tools Menu displays the loop tools and printer menu options. Loop Tools see section 14.3 Printer Menu see section (only appears if a printer is fitted) 14.3 Loop Tools Pressing the loop tools button will show the option for exchanging loop devices. RDM0001/3_2 Page 62 of Protec Fire Detection plc

63 14.4 Exchange Device Menu Do not begin exchanging devices before entering the exchange devices menu. Any MCPs that are to be exchanged must be disabled before exchanging. Pressing exchange devices will allow the level 3a user to begin the process of exchanging a device without the need to re-log and allocate the system. A menu will appear instructing the user to exchange any necessary devices before continuing. All necessary devices must be exchanged before continuing, wait until all relevant device missing and device added faults have been generated before pressing OK. Wait for 3 minutes for the faults to generate before pressing OK, as it is not possible to view the fault menu whilst exchanging and the fault counter will not increment or decrement. A maximum of 8 devices per loop can be exchanged at any one time. Press cancel to exit the exchange menu. Press OK to begin the exchange of devices. RDM0001/3_2 Page 63 of Protec Fire Detection plc

64 After pressing OK select a Panel (section 12.4), Loop Card (section 12.5), and Loop (section 12.6). A warning is given asking if the user wishes to continue, incorrect exchanging of devices could result in a configuration error or the incorrect operation of devices. Press cancel to abandon the exchange or to select a different loop. RDM0001/3_2 Page 64 of Protec Fire Detection plc

65 Press OK to continue with the exchange. After pressing OK the devices that require exchanging will be displayed. Select a device address to be exchanged. Select the replacement device you wish to exchange with. Note that devices of a different type to the original are greyed out and cannot be exchanged. RDM0001/3_2 Page 65 of Protec Fire Detection plc

66 Press cancel to select a different replacement device to exchange with. Press OK to confirm the selection of the replacement device. After pressing OK the user is asked if they wish to save the changes. RDM0001/3_2 Page 66 of Protec Fire Detection plc

67 Press continue to confirm the exchange and continue exchanging further devices (Any changes will not be saved at this stage). After pressing continue the menu reverts to device selection and now displays previously exchanged devices as assigned. Select and exchange any further devices as necessary. After exchanging the final device the user will again be presented with the following menu. Press exit to cancel the exchange and leave the menu (Any changes will not be saved). Press save after all exchanges are finished to save the changes. A progress bar will be displayed whilst the changes are saved. RDM0001/3_2 Page 67 of Protec Fire Detection plc

68 15.0 Appendix A, RVAV Description Availability: RVAV is available on loop devices that have a Fire LED. Format : When the device receives the signal to RVAV, it outputs its address in the following format:- The address is output as hundreds, tens and units with a one and a half second delay between. If the address is less than 100 then the leading zero for the hundreds is not output. The address is determined by counting the LED flashes. A zero is denoted by a long flash of approximately one second. There is a half second delay (approx.) between LED flashes. Address 41 Fire LED State ON OFF = seconds 1.5 seconds Address 05 Fire LED State ON OFF = 05 1 second 1 second See Note below 0.5 seconds Address 102 Fire LED State ON OFF = seconds 1 second Note: The delay following a zero is reduced to one second RDM0001/3_2 Page 68 of Protec Fire Detection plc

69 16.0 Standards, directives and regulations information 0832-CPR-F ag Protec Fire Detection plc, Nelson, Lancashire, England BB9 6RT PFD-CPR-0114 This equipment has been manufactured in conformance with the requirements of all applicable EU council directives and regulations. BS EN 54-2: A1:2006 BS EN 54-4: A1: A2:2006 Control / Indicating and Power Supply equipment for fire detection and fire alarm systems for buildings Options Provided 6500/6600 Fire Alarm Control Panel 7.8 Output to fire alarm devices Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to automatic fire protection equipment (type A) Output to automatic fire protection equipment (type B) Output to automatic fire protection equipment (type C) Fault monitoring of fire protection equipment (type B) 7.11 Delays to outputs Dependencies on more than one alarm signal(type A) Dependencies on more than one alarm signal(type B) Dependencies on more than one alarm signal(type C) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault routing equipment 9.5 Disablement of each point 10 Test condition Supports more than 512 fire detectors and/or manual call points (clause 13.7b) Control & Indicating: Performance under fire conditions: Pass Response delay (response time to fire): Pass Operational reliability: Pass Durability of operational reliability, Temperature resistance: Pass Durability of operational reliability, Vibration resistance: Pass Durability of operational reliability, Electrical stability: Pass Durability of operational reliability, Humidity resistance: Pass Power supply: Performance of power supply: Pass Durability of operational reliability, Temperature resistance: Pass Durability of operational reliability, Vibration resistance: Pass Durability of operational reliability, Electrical stability: Pass Durability of operational reliability, Humidity resistance: Pass RDM0001/3_2 Page 69 of Protec Fire Detection plc

70 The policy of Protec Fire Detection plc is one of continuous improvement. As such we reserve the right to make changes to product specifications at any time and without prior notice. Errors and omissions excepted. Electrical or electronic devices that are no longer serviceable must be collected separately and sent for environmentally compatible recycling (in accordance with the European Waste Electrical and Electronic Equipment Directive). To dispose of old electrical or electronic devices, you should use the return and collection systems put in place in the country concerned. Designed and manufactured in the United Kingdom RDM0001/3_2 Page 70 of Protec Fire Detection plc

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL 6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0)

More information

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL 3500 CONVENTIONAL FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web:

More information

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL 3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web:

More information

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND +44 (0) 1282 717171 www.protec.co.uk sales@protec.co.uk

More information

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections. ISSUES ISSUE DATE RELEASED DETAILS OF CHANGE AUTHOR 4 Rev 2 September 2004 Changes for 4000 series. DB 4 Rev 3 April 2005 Screen shots updated and other minor changes K.Z. 4 Rev 4 September 2006 4 Rev

More information

USER MANUAL & MAINTENANCE GUIDE OG OO

USER MANUAL & MAINTENANCE GUIDE OG OO M+48. USER MANUAL & MAINTENANCE GUIDE OG OO What to do if the Fire Alarm Panel shows an Alarm (Red LED) Write down which LEDs are lit (either in the log book, or on a piece of paper for transferring to

More information

Algo-Tec 6500/6600 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Algo-Tec 6500/6600 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) Algo-Tec 6500/6600 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) COMMISSIONING MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND +44

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax: Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: 01730 268 231. Fax: 01730 265 552 Scimitar user manual & log book SCIMITAR USER MANUAL Approved Document No. DFU7001001 Rev 2

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

FIRE ALARM CONTROL PANEL FVC01-08

FIRE ALARM CONTROL PANEL FVC01-08 FIRE ALARM CONTROL PANEL FVC01-08 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Radal Technology Limited Unit 1, Webber Court Billington Road, Burnley Lancashire, BB11 5UB Tel: +44 (0) 1282 463 770 Fax: +44

More information

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL 3500 CONVENTIONAL FIRE ALARM CONTROL PANEL INSTALLATION AND COMMISSIONING MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax:

More information

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater APPROVED BY: JBJ Precept EN Fire Detection/Alarm Panel & Precept EN Repeater Logbook PAGE 1 of 19 List of Contents 1. FIRE ALARM SYSTEM MAINTENANCE... 3 2. USER RESPONSIBILITIES... 3 2.1. RESPONSIBLE PERSON...

More information

HERCULES 6 GRAPHICS SYSTEM

HERCULES 6 GRAPHICS SYSTEM HERCULES 6 GRAPHICS SYSTEM USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web: www.protec.co.uk

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd Product Data Sheet Mx-4000 Series User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels The operation and functions described in the manual are available from Software Versions

More information

ID2000. operating manual

ID2000. operating manual ID2000 operating manual 997-434-000-2, Issue 2 Contents ID2000 Series Operating Manual Contents 1 Introduction 1 1.1 Associated Documents 1 1.2 The ID2000 Panels 1 1.3 Cleaning 2 2 Panel Controls and Indicators

More information

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK ONE TO FOUR LOOPS ANALOGUE ADDRESSABLE FIRE ALARM PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Page 1 TABLE OF CONTENTS WHAT TO DO IF THE FIRE ALARM PANEL SHOWS AN ALARM (RED LED)... 4 WHAT TO DO IF

More information

user manual Document No , Revision 03 November 2015

user manual Document No , Revision 03 November 2015 user manual Document No. 996-202-600-3, Revision 03 November 2015 Contents 1 Introduction...1 1.1 Notice...1 1.2 Models...1 2 User Control Levels...2 2.1 Level Definition...2 2.2 User Passwords...2 3 Controls

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Protec Protec Algo-TecTM 6100 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL

More information

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Operating instructions SENTRI4 Control panel based Fire detection and alarm system 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 30 32 Zones Healthy 15:45 Fault Power Fault System Fault SenTRI 4 Fire System Designed to EN54 Pt 2 & 4 Operating instructions

More information

Control Panel User Guide

Control Panel User Guide Fire Detection & Alarm System Control Panel V4.14 Control Panel User Guide (TO BE RETAINED BY USER) 26-0397 Issue 6 Fike s policy is one of continual improvement and the right to change a specification

More information

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS CONTENTS 1. System Overview 2. User responsibilities 3. First Line controls and indications 3.1 Logging on to the fire alarm system 3.2 Checking system status

More information

Fire Alarm Control Panel. System Maintenance and Log Book

Fire Alarm Control Panel. System Maintenance and Log Book Fire Alarm Control Panel System Maintenance and Log Book Fire Alarm System Maintenance A fire alarm system must provide early and reliable warning of the outbreak of fire. To achieve this, the system remains

More information

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK INTELLIGENT 2 WIRE FIRE DETECTION SYSTEM WITH ID TECHNOLOGY USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT2-211-7-2 PAGE 0 TABLE OF CONTENTS WHAT TO DO IF THE FIRE ALARM PANEL SHOWS

More information

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK. CONTENTS 1. FIRE ALARM CONTROL PANEL SAFETY

More information

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system SenTRI ONE panel-based Fire detection and alarm system one 042bc/14 4188-978 issue 2_04-10_SenTRI ONE system oper Part of Document pack 2535-235 issue 2 1 Contents User responsibility - - - - - - - - -

More information

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Firmware Versions: PANEL 1.84 & LOOP CARD 3.70 MKII PROTOCOL ONE TO FOUR LOOPS ANALOGUE ADDRESSABLE FIRE ALARM PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK #Doc No. GLT-215-7-2 TABLE OF CONTENTS WHAT

More information

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 PREMIER EX8 EXTINGUISHING PANEL USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 & EN54 PARTS 2 & 4 USER MANUAL Approved Document No: GLT.MAN-132 INDEX Extinguishing

More information

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK ONE OR TWO LOOP ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-108 TABLE OF CONTENTS WHAT TO DO IF THE FIRE ALARM PANEL SHOWS AN ALARM

More information

Fire detection and alarm system Operating instructions

Fire detection and alarm system Operating instructions Fire detection and alarm system Operating instructions Operating instructions Table of Contents User responsibility - - - - - - - - - - - - 4 Daily - - - - - - - - - - - - - - - - - - - 4 Weekly - - -

More information

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL. user manual and log book. approved document no. DFU Rev 1

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL. user manual and log book. approved document no. DFU Rev 1 XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL user manual and log book approved document no. DFU2000501 Rev 1 CONTENTS Important safety notes...3 Introduction...4 Fire alarm systems - an

More information

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM 2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM OPERATING INSTRUCTIONS MODELS: 2300 2500 2700 This information is relevant to systems fitted with Issue 4.1 (or later) Master Keypad Software, also to Networked

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

Control Panel User Guide

Control Panel User Guide Fire Detection & Alarm System Control Panel (Suitable for TWINFLEX pro control panels from V1.00) Control Panel User Guide (TO BE RETAINED BY THE USER) 26-1028 Issue 2 Fike s policy is one of continual

More information

Fire Command Keypad. XR5 User s Guide

Fire Command Keypad. XR5 User s Guide Fire Command Keypad XR5 User s Guide Silencing an Alarm While the fire alarm horns, strobes, or sirens are sounding use one of the following methods to silence the alarm depending on which type of keypad

More information

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels The panels are designed in accordance with the requirements of EN54 Part 2:1997 (and include optional clauses

More information

Control Panel User Guide (TO BE RETAINED BY THE USER)

Control Panel User Guide (TO BE RETAINED BY THE USER) Fire Detection & Alarm System Control Panel V3 (Suitable for Quadnet control panels from V2.00) Control Panel User Guide (TO BE RETAINED BY THE USER) 26-0585 Issue 7 Fike s policy is one of continual improvement

More information

ZP3 Operator & Maintenance Manual Version 1

ZP3 Operator & Maintenance Manual Version 1 ZP3 Operator & Maintenance Manual Version 1 Introduction Thank you for selecting Clymac Ltd. Clymac can provide maintenance for the system, emergency call out, telephone support and any modifications required

More information

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: EF-PFC8UM-1 Contents 1. FIRE ALARM CONTROL PANEL SAFETY ISSUES... 2 2. THE PURPOSE OF A FIRE ALARM SYSTEM... 2 3.

More information

user manual and log book XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL

user manual and log book XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL f i r e s a f e t y e q u i p m e n t 8 Arkwright Court, Fylde Industrial Estate, Blackpool, Lancashire FY4 5DR. Sales Tel: 01253 699500 (Fax:

More information

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u 8 plus and16 plus User s Guide GALAXY 16+ V2.XX 06.22 TUE 30 JUN 1 2 3 4 5 6 7 8 9 0 * # A u B u ent esc IU1-0018 ZST 962 Issue 2 Contents INTRODUCTION... 1 Glossary of Terms... 3 KEYPAD INFORMATION...

More information

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

ZERIO PLUS EDA-Z5008, Z5020 & Z5100 ZERIO PLUS EDA-Z5008, Z5020 & Z5100 USER MANUAL Revision 1.00 EDA-Z5008, Z5020 & Z5100 User Manual 0359 Electro Detectors Limited Electro House Edinburgh Way Harlow, Essex CM20 2EG, UK 14 0359 CPR 00226

More information

General Alarm System. User Manual. Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND

General Alarm System. User Manual. Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND General Alarm System User Manual Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND +44 (0) 1282 717171 www.protec.co.uk sales@protec.co.uk Document Revision Details

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Fire Detection - Addressable Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Fire Detection - Addressable Protec Protec Algo-TecTM

More information

Document No Issue 4 user manual

Document No Issue 4 user manual DX Document No. 996-148-000-4 Issue 4 user manual Dimension Series Table of Contents 1 INTRODUCTION... 5 1.1 NOTICE... 5 1.2 MODELS... 5 1.3 WARNINGS AND CAUTIONS... 7 1.4 NATIONAL APPROVALS... 7 1.5 EN54

More information

Operating instructions Vigilon panel and Network node Fire detection and alarm system

Operating instructions Vigilon panel and Network node Fire detection and alarm system Healthy 15:45 Fault Power Fault Vigilon Fire System GENT 2015 Designed to EN54 Pt 2 & 4 System Fault Operating instructions Vigilon panel and Network node Fire detection and alarm system Test Fire Fault/Dis

More information

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0)

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels The panels are designed in accordance with the requirements of EN54 Part 2:1997 (and include optional clauses

More information

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual Conventional Fire System BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual Contents Contents 1. INTRODUCTION... 3 1.1 Purpose...3 1.2 Definitions....3 Premises Management...

More information

Firetrax Professional Conventional Fire Control Panel

Firetrax Professional Conventional Fire Control Panel Firetrax Professional Conventional Fire Control Panel User manual & Log Book Printed : 04/01/2010-1 - Printed : 04/01/2010-2 - FireTrax VFT-P User Guide VI53.1 Ventcroft Ltd VFT-P 1/2/4/6/8Conventional

More information

ZSC100 Gas Detection and Alarm System Controller

ZSC100 Gas Detection and Alarm System Controller ZSC100 Gas Detection and Alarm System Controller User Guide 1- Introduction... 3 1.1- General description... 3 1.2- Cautions and warnings... 3 2- Control panel... 4 2.1 Control panel overview... 4 2.2

More information

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03 HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS User Manual Approved Document UI-ELAN-02 Revision 03 This page is intentionally blank Page 2 of 42 Table of Contents 1 INTRODUCTION 5 1.1 Standards

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1 ViewMatrix Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels Version: 2.0 Revision: 0.1 CONTENTS 1. Introduction...3 2. Keyboard...5 2.1 POWER indication - Normal Operation...5

More information

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00 PAT E N T System 88 COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00 Pg 1 of 12 CONTENTS 1. GENERAL 1.1 Introduction 2 1.2 System Description

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

2200 and 2200L ALARM CONTROL SYSTEMS

2200 and 2200L ALARM CONTROL SYSTEMS 2200 and 2200L ALARM CONTROL SYSTEMS OPERATING INSTRUCTIONS MODELS: 2200 (fitted software 3.4 or later) 2200L (fitted software 3.9L or later) Castle Care-Tech Ltd. 2200/2200L Alarm System Operating Manual

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Fire Detection Pty Ltd Fire Detection - Addressable Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Fire Detection

More information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check

More information

M800, M800iD Plus, M1000 and M3000. User's Guide

M800, M800iD Plus, M1000 and M3000. User's Guide M800, M800iD Plus, M1000 and M3000 User's Guide Cooper Security Limited 2005 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security

More information

HARDWIRED CONTROL PANELS

HARDWIRED CONTROL PANELS USER'S GUIDE HARDWIRED CONTROL PANELS Cooper Security Limited 2007 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security Limited

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

User Operation Manual

User Operation Manual APPROVED BY: JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL User Operation Manual PAGE 1 of 6 1 CONTENTS 1. FIRE - GENERAL... 3 2. FIRE - ZONES 1 OR 2 - AUTOMATIC MODE... 3 3. FIRE - ZONES

More information

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3 INTELLIGENT FIRE TECHNOLOGY Twinflex and Multipoint V3 User Guide (TO BE RETAINED BY USER) 26-0340 Issue 3 Rafiki Protection Limited Rafiki policy is one of continual improvement and the right to change

More information

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL Fire Alarm Control Panel & MANUAL CONTENTS SECTION -. Description of the fire control panel fascia.... Alarm.... Reset the system.... Sound and silence the alarms.... Read the Fire, Fault, Test and Disabled

More information

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 2 Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd Operating Guide Proudly Designed and Manufactured in New Zealand 1 CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET E n t er y ou r pa s s c o de X X X X th en l ea v e th e p r o tec t e d a re a. G o dir e ct ly to t h e k e yp ad an d en te r y ou r p as s c o d e X X X X. E n t er y ou r pa s s c o de X X X X f

More information

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996 User responsibility SYSTEM 3400 (with 34000 Devices) Control and indicating equipment Quick reference Emergency conditions ANALOGUE ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Other controls Site labels

More information

SYSTEM 5000 USER MANUAL

SYSTEM 5000 USER MANUAL SYSTEM 5000 USER MANUAL Table of Contents Section Page No 1 Introduction: -... 3 1.1 Procedure:... 3 1.2 Warnings and Cautions:... 3 2 User Control Levels:... 4 3 User Passwords:... 4 4 Controls and Displays:

More information

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998

More information

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming Master Code The 4 digit Master Code is used for arming and disarming the system, for programming additional access codes, and for changing other features. The Master Code will be supplied to you by your

More information

IDS816 User Manual H Issued January 2009

IDS816 User Manual H Issued January 2009 1 Contents Glossary-------------------------------------------------------------------------------------------------------------------6 1. Introduction to the IDS 816---------------------------------------------------------------------------7

More information

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book Noby-448 User Operating Manual & Log Book Page 1 of 12 Fire Control Panel User Operating Manual & Log Book TABLE OF CONTENTS Page Introduction 1 Keypad Operation 2 LED Indications 3 What to do in the event

More information

QUICK USER GUIDE. Alarm Control Panel

QUICK USER GUIDE. Alarm Control Panel Alarm Control Panel Firmware version 2.10 QUICK USER GUIDE The full version of User Manual and other manuals are available on CD included in the control panel delivery set or on the website www.satel.eu

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04

More information

INTRUDER ALARM FOR BUSINESS SECURITY

INTRUDER ALARM FOR BUSINESS SECURITY INTRUDER ALARM FOR BUSINESS SECURITY WELCOME PACK THANK YOU FOR CHOOSING ADT Thank you for choosing us to help protect your business and employees. Please take the time to read your Welcome Pack carefully

More information

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 6 Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels CF5000, MF5000 and FXP5000 Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels 16 zone panels Contents PANEL INSTALLATION...3 Installation...3 PANEL WIRING... 3 Mains power

More information

ZP2 Series Operation Manual

ZP2 Series Operation Manual ZP2 Series Operation Manual P/N 501-405203-2-31 REV 03.10 ISS 07NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire & Security.

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

IDS800 USER MANUAL. Summary of Operation.   + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay Arm Stay Arm & Go H old down [ 1] for 1 second H old down [ 5] for 1 second H old down [ 6] for 1 second Panic Fire Medical

More information

KFP-CF Series Operation Manual

KFP-CF Series Operation Manual KFP-CF Series Operation Manual P/N 501-415103-2-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS USER GUIDE HARDWIRED CONTROL PANELS Scantronic Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 3 The 725r Remote Setting Device... 6 About This Guide... 6 2. Everyday Operation... 7

More information

NX-148 LCD CODE PAD TABLE OF CONTENTS

NX-148 LCD CODE PAD TABLE OF CONTENTS NX-148 LCD CODE PAD TABLE OF CONTENTS Glossary Of Terms... 4 Understanding The Lights... 5 Code Pad Functions Arming In The ON Mode... 6 Making The System Ready To Arm... 7 Using Quick Arm... 7 Arming

More information

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9 Index Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8 Fire Risk Assessments 9 Fire Alarm Systems 10-20 Locations 10 Servicing 11 12 Activations 13 14 Weekly Checks

More information

The Protec driver connects to the Protec Fire Detection range of digital addressable fire control panels. Available for Commander and ObSys.

The Protec driver connects to the Protec Fire Detection range of digital addressable fire control panels. Available for Commander and ObSys. The Protec Driver The Protec driver connects to the Protec Fire Detection range of digital addressable fire control panels. Available for Commander and ObSys. This document relates to Protec driver version

More information

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England Tel: 01709 700100 Fax: 01709 701042 INT'L Tel: +44 1709 700100 INT'L Fax: +44 1709 701042 WARRANTY This

More information

Fire Detection - Addressable

Fire Detection - Addressable Technical Specification 6400 Series Common Specifications Temperature Range 0-40 C. Maximum Humidity 85% Non-Condensing. Working Voltage 21.5-30V dc. Secure Network Dual channel RS485 fault tolerant communications

More information

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

IDS S E C U R I T Y IDS816.  User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-02A ISSUED November 2004 VERSION 1.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3.

More information

INTRUDER ALARM FOR BUSINESS SECURITY

INTRUDER ALARM FOR BUSINESS SECURITY INTRUDER ALARM FOR BUSINESS SECURITY WELCOME PACK THANK YOU FOR CHOOSING ADT Thank you for choosing us to help protect your business and employees. Please take the time to read your Welcome Pack carefully

More information

NetworX NX-8V2. LED Keypad User Manual

NetworX NX-8V2. LED Keypad User Manual NetworX NX-8V2 LED Keypad User Manual POWER Light is on when AC power is present; flashes to indicate a low battery condition. ARMED Light is on when armed; off when disarmed; flashes to indicate a previous

More information

Security System. User s Guide for the Text Command Center

Security System. User s Guide for the Text Command Center User s Guide for the Text Command Center MY ALARM COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE JACK LOCATED:

More information

PROPOINTPLUS ASPIRATING SMOKE DETECTION SYSTEM

PROPOINTPLUS ASPIRATING SMOKE DETECTION SYSTEM PROPOINTPLUS ASPIRATING SMOKE DETECTION SYSTEM INSTALLATION AND COMMISSIONING MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND +44 (0) 1282 717171 www.protec.co.uk

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

ZITON RADIO LOOP MODULE

ZITON RADIO LOOP MODULE ZITON RADIO LOOP MODULE PROGRAMMING MANUAL Table of Contents Section Page No 1.0 INTRODUCTION...3 1.1 System Design...3 1.2 Handling Precautions...3 1.3 Packaging:...3 2.0 MENU STRUCTURE...4 2.1 Menu Structure

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

16 and 16 plus User s Guide

16 and 16 plus User s Guide 16 and 16 plus User s Guide GALAXY 16+ V2.XX 06.22 TUE 30 JUN 1 2 3 4 5 6 7 8 9 * 0 # A u B u ent esc Contents INTRODUCTION... v QUICK OPERATION GUIDE...vii GLOSSARY OF TERMS... ix KEYPAD INFORMATION...

More information

5000 SERIES 8 ZONE INSTRUCTION MANUAL

5000 SERIES 8 ZONE INSTRUCTION MANUAL 5000 SERIES 8 ZONE INSTRUCTION MANUAL NESS SECURITY PRODUCTS 4/167 PROSPECT HIGHWAY SEVEN HILLS. 2147 NSW AUSTRALIA SYDNEY Phone: (02) 8825 9222 (Head Office) BRISBANE Phone: (07) 3343 7744 MELBOURNE Phone:

More information