ENERGY STAR Program Requirements

Size: px
Start display at page:

Download "ENERGY STAR Program Requirements"

Transcription

1 Report No.: LCZP Version: 1.0 Date Of Issue: Jun. 17, 2017 Total Pages: 17 Test Report of ENERGY STAR Program Requirements for Luminaires V2.0- Inseparable SSL Luminaires Applicant: ELEC-TECH INTERNATIONAL CO LTD No.1JinfengRoad, Tangjiawan Town, Xiangzhou District, ZhuhaiCity, Guangdong Province, P.R. China Manufacturer: 1.GUANGDONG NVCETi Lighting Co,.Ltd Factory 2#-2 No.1 South ZhongZhu Rd.,Science & Technology Innovation Coast, High Tech District, Zhuhai City, Guangdong Prov., China WUHU 3E LIGHTING CO LTD 11 WEI ER CI RD EASTERN WUHU ECONOMIC & TECHNOLOGICAL DEVELOPMENT AREA WUHU ANHUI China Models: ##, ##(##=41-50) (Where ## denotes CCT and could be which refers 4000K.) Test Date: From Jun. 02, 2017 to Jun. 14, 2017 Test Lab.: Template No.: Lab. Note: 2/F., Technology and Enterprise Development Center, Guangyuan Road, Xiaolan, Zhongshan, Guangdong, China Tel: Fax: LC-RT-PL/ES/Luminaire2.0/LED ## and546554## areallthesame except the modelnumber. Complied by: Fish Tan Reviewed by: Richard Li Project Engineer Technical Manager Jun. 17, 2017 Jun. 17, 2017 The duplication of this report or parts of it and its use for advertising purposes is only allowed with permission of the testing laboratory. This report onlycontains the result of the examination of the product samples submitted by the applicant.a general statement concerning the quality of the products from the series manufacture cannot be derived therefore.

2 Content Page 2 of 17 Ref.No.: LCZP , V General Product information Sample Received Record: Reference standards or methods Equipment list Test conducted and method Test conducted Light Output, Efficacy, and color quantities ISTM and TM Start Time Test Transient Protection Test Standby power consumption test Operating Frequency Thermal Performance Test DimmingTest (only for luminaires marked as dimmable) Test Result Summary Test Data Initial Photometric and Electrical Data In-situ TMP LED and TMP c Other Test Data...14 Appendix-A LM-80 Report information...15 Appendix-B TM Appendix-C Photos...16 Appendix-D Report Update Record...17

3 1. General 1.1 Product information Brand Name Page 3 of 17 Ref.No.: LCZP , V1.0 ETI Model Number ##, ##(##=41-50) Indoor or Outdoor Indoor Inseparable SSLLuminaires Type Inseparable SSLLuminaire-Shop Light Rated Input VAC, 50/60Hz Rated Power 20W Rated Initial Light Output 1800lm Nominal CCT 4000K LED Package,Array or Module Model: SPMWH1228xxxxxxxxx, manufactured by SAMSUNG ELECTRONICS CO LED LM-80 Test Information Please refer toappendixa-1 for detail information. Driver Information LED driver Dimming Information Dimmable Luminaire Features Continuously Dimmable ConnectedLuminaire or not Not Note Sample Received Record: Date Model Numbers Sample Code of lab. 2017/05/ ##(##=41-50)

4 1.3 Reference standards or methods Page 4 of 17 Ref.No.: LCZP , V1.0 The followingstandards are partly or totally used or referenced fortest and report. No. Name ANSI/NEMA/ANSLG Specifications for the Chromaticity of SolidStateLighting Products C ANSI/ANSLG C Specifications for Bases (Caps) for Electric Lamps ANSI/ANSLG C Lamp holders for Electric Lamps ANSI C Harmonic Emission Limits Related Power Quality Requirements for Lighting Equipment ANSI/IEEE C IEEE Guideon the Surge Environment in Low-Voltage (1000V and Less)AC Power Circuits ANSI/IEEE C IEEE Recommended Practiceon Characterization of Surges in Low-Voltage (1000V and Less)AC Power Circuits ANSI/UL Standard for Safety of Portable Electric Luminaires ANSI/UL Standard for Safety of Class 2Power Units ANSI/UL Standard for Safety of Track Lighting Systems ANSI/UL Standard for Safety of Luminaires ANSI/UL 1598C Light-Emitting Diode (LED) Retrofit Luminaire Conversion Kits ANSI/UL Self-Ballasted Lamps and LampAdapters ANSI/UL Standard for Low-Voltage Lighting Systems ANSI/UL Standard for Light Emitting Diode (LED) Equipment for Use in Lighting Products ASTM E Standard Test Method for Determining Rate ofair Leakage Through Exterior Windows, CurtainWalls, and Doors Under Specified Pressure DifferencesAcross the Specimen CIE Pub. No Method of Measuring and Specifying Color Rendering of Light Sources CIE Pub. No. 15:2004 Colorimetry EU Directive 2002/95/EC Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the Restriction of the Use of Certain Hazardous Substances In Electrical and Electronic Equipment FCC CFRTitle 47 Part15 Radio Frequency Devices FCC CFRTitle 47 Part18 Industrial, Scientific, and MedicalEquipment IEC (2012) Lamp Caps and HoldersTogether with Gauges for the Control ofinterchangeability and Safety Part 1: Lamp Caps IEC ED.2.0 B:2011 Household electrical appliances - Measurement ofstandbypower IEC Ed. 1.0 Electrotechnical Products - Determination Of Levels Of Six Regulated Substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominateddiphenyl ethers) IEEEPAR1789 IEEE Recommending Practices for Modulating Current in High BrightnessLEDs for Mitigating Health Risks to Viewers IES LM Method for Spectroradiometric Measurement Methods for Light Sources IES LM Electrical and Photometric Measurements of Solid-State Lighting Products IES LM Measuring Lumen Maintenance of LED Light Sources

5 IES LM IES LM IES RP IES TM IESTM NEMA LSD Page 5 of 17 Ref.No.: LCZP , V1.0 IESApproved Methodfor thecharacterization of LED LightEnginesandIntegrated LED Lampsfor Electrical and Photometric PropertiesasaFunctionofTemperature Measuring Luminous Flux and Color Maintenance of LED Lamps, Light Engines, and Luminaires Nomenclatureand Definitionsfor IlluminatingEngineering Projecting Long Term Lumen Maintenance of LED Sources Projecting Long-Term Luminous FluxMaintenance ofled Lamps and Luminaries Recommendations for Solid State Lighting Sub-Assembly Interfaces for Luminaires NEMA SSL 7A-2013 Phase Cut Dimming for Solid State Lighting: Basic Compatibility ENERGY STAR ENERGY STAR Program Requirements for Lamps and Luminaires Start TimeTest Method (September 2015) 1.4 Equipment list All the equipment for the measurements were calibrated by ISO accredited laboratory or traceable to National Institute of Metrology (NIM) or National Institute of Standards and Technology (NIST), below are equipment list. Instrument ID Model name Cal. date Next cal. Date AC power supply LC-I-923 CHP AC power supply LC-I-987 APW-120N AC power supply LC-I-988 APW-120N AC power supply LC-I-989 APW-120N DC Power Source LC-I-947 IT AC Power Source LC-I-948 AFW-215A Before used Before used AC Power Source LC-I-950 AFW-215A Before used Before used Power analyzer LC-I-928 WT Power analyzer LC-I-954 WT Power analyzer LC-I-977 WT Digital caliper LC-I-973 (0~200)mm Photometric colorimetric electric system (2 meter sphere) LC-I-900 SPR3000 Before used Before used Standard lamp LC-PL-I V100W Luminous Flux Standard Lamp LC-PL-I V/200W Timer LC-I DH48S-S Timer LC-I DH48S-S Life test system LC-I-930 LCTECH-1 Before used Before used Temperature chamber LC-I-920 DY Goniophotometer(with mirror) LC-I-902 GMS Digital oscilloscope LC-I-919 TDS Sound level meter LC-I-951 AWA Anechoic room LC-I-952 TNX Steel tape LC-I-992 (0-5)m Wireless temperature transmitter Wireless temperature transmitter LC-I-978 DWRF-B LC-I-979 DWRF-B Wireless temperature LC-I-980 DWRF-B

6 transmitter Wireless temperature transmitter Wireless temperature transmitter Wireless temperature transmitter Page 6 of 17 Ref.No.: LCZP , V1.0 LC-I-981 DWRF-B LC-I-982 DWRF-B LC-I-983 DWRF-B Surge CDN LC-I-832 SGN-5010G Surge Tester LC-I-831 SGZ-6012G J thermocouple LC-I-096 TT-J-30-SLE(200m /r) Data acquisition/switch unit LC-I A

7 2. Test conducted and method 2.1 Test conducted Page 7 of 17 Ref.No.: LCZP , V Light Output, Efficacy, and color quantities The sample was first used to color and photometric quantities measurements by spectroradiometer with 2 meters integrated sphere (4 )and power analyzer The sample was tested without seasoning according to LM-79. Before measurements were taken, the sample was operated for about 2hours to reach stabilization and temperature equilibrium. Stabilization in which the variation (maximum -minimum) of atleast 3readings of the light outputand electricalpower over aperiod of 30min, taken15minutes apart, is less than 0.5%. The ambient temperature in the whole test process was kept in 25 1 C, and the sample was in its designated orientation for all the measurements as LM-79 requirement ISTM and TM The LED module used in the luminaire was tested in accordance with ANSI/UL 1598(Section 19.7, ), ANSI/UL 1574 Section 54 oransi/ul 153(Sections A) and LM Thermocouples were in contact with the TMP LED location described in LM-80 test report. In order to gain the maximum temperature, if appropriate, more than one thermocouple may use The sample was tested in the housing as provided by customer which was the designated application, and the housingwiththesamplewasmountedaccordingto the standard requirement The sample was operated for 7.5 hours to obtain constant temperatures, an Agilent data logger was used for data recording The ambient temperature was kept in25 5 C, andfinalmeasured values were normalized to an ambient of 25 C.The sample was inits designated orientation Start Time Test The luminaire was not seasoned beforetest. Start timewas measured by digital oscilloscope and photometer Connect oscilloscope probe to measure the input voltage to the luminaire, and light output Set trigger level at 10V to trigger off the input voltage signal Set the power supply to rated voltage and frequency of the device (Normal 120V/60Hz applied). If arange is specified, test sample at the midpoint of the range Record the input voltage, light output waveform, and starting time based on 98% of initial plateau of light output onwhichthestartingtimewas based The ambient temperature in the whole test process was kept in 25 1 C, and in its designated orientation Transient ProtectionTest The line transient was consisting of seven strikes of a100 khz ring wave, 2.5 kv level, for both common mode and differential mode. Here is the 100 khz RingWave Graph:

8 Page 8 of 17 Ref.No.: LCZP , V The ambient temperature was kept in 25 5 C, and the sample was in its designated orientation Standby power consumption test The tests shall be carried out in aroom that has an air speed close to the product under test of 0.5 m/s. The ambient temperature shall be maintained at 23 C 5 C throughout the test For input powers less than or equal to 1W, stability is established when alinear regression through all power reading for the second two thirds of the total period has aslope of less than 10 mw/h. for input powers of more than 1W, stability is established when a linear regression throughall power readings for the second two thirds of the total period has a slope of less than is 1 % of the measured input power per hour Operating Frequency Operating frequencywas measuredbyoscilloscopeand photodetector whichcan capture the light output with an interval less than 50 microseconds (Sample rating no less than 20 KHz). The actual used oscilloscope has a sample rating of 1GS/s An image of the relative photometric waveform which contains more than 8 cycles was recorded The lightoutput dataof no less than 1secondwere captured and recorded too Frequency was calculated based the light output data captured The ambient temperaturewaskeptin25 1 C, and the samplewas in itsdesignatedorientation Thermal Performance Test The LED driver used in the luminaire were tested in accordance with ANSI/UL 1598(Section 19.7, ), ANSI/UL 1574 Section 54 oransi/ul 153(Sections A) Thermocouples were in contact with the TMP C location of LED driver as designated by manufacturer The sample was tested in the housing as provided by customer which was the designated application, and the housingwiththesamplewasmountedaccordingto the standard requirement The sample was operated for 7.5 hours to obtain constant temperatures, an Agilent data logger was used for data recording The ambient temperature was kept in25 5 C, andfinalmeasured values were normalized to an ambient of

9 Page 9 of 17 Ref.No.: LCZP , V C.The sample was inits designated orientation Dimming Test (only for luminaires marked as dimmable) Set and apply 120V-60HzAC power to the device Adjust the dimmer to the maximum and minimum light output with recommended dimmer, measure the light output by a2 meters integrated sphere (4 ). The lowest light output level was recommended by customer The sample was connected to adimmer recommended by customer and operated in center of an anechoic room with abackgroundnoiselower than15 dba.the microphonewas located at place lessthan1meter at theminimum output; maximum value was used as the test result During the whole tests, ambient temperature was kept in 25 1 C, and the sample was in its designated orientation.

10 3. Test Result Summary Page 10 of 17 Ref.No.: LCZP , V1.0 Item Result Requirement Power Measured: W Reported: 20 W None Luminaire Efficacy (initial) Measured: lm/w Reported: 90 lm/w 70 lm/w Luminaire Light Output (initial) Correlated color temperature Color Rendering Index Measured: lm Reported: 1800 lm Measured: 4021 K fallswithinthe4000k 7-step chromaticity quadrangles Ra: 90.6 R9: lumens Luminaire shall have oneof correlated colortemperatures 2700 K, 3000 K, 3500 K, 4000K, and 5000 K. The luminaire shall fall within the corresponding 7-step chromaticityquadrangles as defined inansi/nema/anslg C Ra 80 R9 0 Projected Life _TM-21 Method In situ TMP LED : 48.0 C Current on each LED: 120 ma Projected L 70 Life:>54000 LM-80 with TM-21 method: L 70 lumen maintenance life shall meet the follow: L70(6k) 25,000 hours for indoor ( hours) Color Maintenance Gained from LM-80 report, refer to Appendix A for LM-80 report summary. Start time 256 ms Power factor Transient Passed protection Standby Power Consumption 0.0 W LM-80 method: Luminaire change in chromaticity coordinates from 0-hour measurement, at any measurement point during operation, shall be a total linear distance of on the CIE 1976 u v diagram Non-Connected Luminaires: 750ms Connected Luminaires: 1000 ms Total input power 5 watts: PF 0.5 Total input power >5 watts: PF 0.7 Luminairesshallsurvive 7strikes of a 100kHz ring wave, 2.5 kv levelfor bothcommon model and different mode Luminaires without sensors: 0.0W Luminaires with sensors/or connected luminaires: 0.5W

11 Operating Frequency Maximum Ballast or Driver Case Temperature Dimming Requirements Connected Functionality (Option) Light Source Shipment Page11 of 17 Ref.No.: LCZP , V Hz. Minimum: 9.259kHz Dimming operation shall meet the requirement at all light output levels Measured temperature at the TMP C shall be less than or 51.2 C equal to the manufacturer recommended temperature 100 C. Dimming Range: Measured dimmingfrom All luminairesmarked as dimmable. 100% to 9.9% The luminaire and itscomponentsshallprovide continuous Reported dimming from dimming from 100% to 20% of light output. 100% to 10% Noise: All luminairesmarked as dimmable. 20.1dBA 24dBA at 1meter or less at the minimum output N/A Exemption fornon-connected functionality products Light Sourceshipped with the Complete light source components shall be provided with luminaires theluminaire or retrofit kit.

12 4. Test Data 4.1 Initial Photometric and Electrical Data Page 12 of 17 Ref.No.: LCZP , V1.0 Voltage Current Power Light output Luminaire efficacy Power factor (V) (A) (W) (lm) (lm/w) Chromaticity Chromaticity CCT Ra R9 Duv (x) (y) (K) ANSI Chromaticity Quadrangles Diagram

13 4.2 In-situ TMP LED and TMP c Page 13 of 17 Ref.No.: LCZP , V1.0 TMP LED( ) TMP C(driver temperature) ( ) LED Numbers: 60 Units Thermocouple contact photograph (TMP LED): Thermocouple contact photograph (TMP c):

14 4.3 Other Test Data Test Item Page 14 of 17 Ref.No.: LCZP , V1.0 Test Result Start time 256 ms Frequency (Minimum) 9.259kHz Standby power 0.0 W Transient protection Passed Dimming Dimming Range Maximum light output Minimum light output Diming range Dimming from 100% lm lm to 9.9% Noise: 20.1 dba Note: Test Dimmer model number: Lutron NFTV

15 Appendix-A LM-80 Report information Page 15 of 17 Ref.No.: LCZP , V1.0 Report originated by BayArea Compliance Laboratories Corp. (Dongguan). Manufactured by Samsung Electronics Co., LTD. LM-80 report No. RSZ LED Model SPMWH1228xxxxxxxxx LED Part Number SPMWH1228FD5WAW0xx Number of LED light source tested 25 units per case temperature Drive Current 120mA Case temperature lumen maintenance during 9000 hours test 98.82% 98.17% 97.66% Color maintenance( u v ) during 9000 hours test Appendix-B TM-21 TM-21 Inputs Instructions Yellow fields are completed by the user. Fields not used should be left blank. Cyan fields are calculated based on user entries. First, enter a description of the LED light source tested. Then complete the fields labeled "LM-80 Testing Details". Test durationmust be at least 6,000 hours. If only one case temperature data set is to be used (no interpolation), complete only "Tested case temperature1". For only two case temperaturedata sets, complete 1 and 2. Next, further to the right, in the corresponding box(es) for each tested case temperature, enter the test data along with the time (inhours) at which eachmeasurement was taken. Data entered must be normalized then averaged measured data (per TM-21 sections and 5.2.2). If case temperatures havedifferent test durations, enter data up to the lowest of the test durations for all of the case temperatures. Enter drive current, in-situ temperature data and the percentage of initial lumens to project to in the fields labeled " In-Situ Inputs". Results can be tailored to estimate lumen maintenance at a specific time by entering a value (t) in the yellow field. A complete TM-21 report will appear on the next tab labeled "Report". Descriptionof LED Light Source Tested (manufacturer, model, catalog number) Model: SPMWH1228xxxxxxxxx, SamsungElectronics Co., LTD. Time (hours) Lumen Maintenance (%) Time (hours) LumenMaintenance (%) Time (hours) Lumen Maintenance (%) % % % % % % % % % % % % % % % LM-80 Testing Details % % % Total number of units tested per case temperature: % % % Number of failures: % % % Number of unitsmeasured: % % % Test duration (hours): % % % Tested drivecurrent (ma): 120 Tested case temperature1 (T c, C): 55 Tested case temperature2 (T c, C): 85 Tested case temperature3 (T c, C): 105 In-Situ Inputs Drive current for each LED package/array/module (ma): 120 In-situ case temperature (T c, C): 48 Percentage of initial lumens to project to (e.g. for L 70, enter 70): Results Time (t) at which to estimate lumen maintenance (hours): 6,000 Lumen maintenance at time (t) (%): 99.29% Reported L70 (hours): > LM-80 Test Inputs Test Data for 55 C Case Temperature Test Data for 85 C Case Temperature Test Data for 105 C Case Temperature

16 Appendix-C Photos Page 16 of 17 Ref.No.: LCZP , V1.0 Representative Model Top View: Representative Model Back View:

17 Appendix-D Report Update Record Report Version Update Time Update content V /06/17 Initial report. Page 17 of 17 Ref.No.: LCZP , V1.0 ****End of test report****

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight Directional Luminaire Test Report For ELEC-TECH INTERNATIONAL CO LTD No. 1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R.China 519085 LED Downlight Model name(s):

More information

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C IESNA SUSTAINING MEMBER Test report of In Situ Temperature Measurement And Lumen Maintenance Projection Rendered to: LIGHT EFFICIENT DESIGN, DIV OF TADD LLC 188 S. Northwest Highway Cary, IL60013 For products:

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G101030158 Date: February 26, 2013 REPORT NO. 101030158CRT-001 TEST OF ONE LED

More information

In Situ Temperature Measurement

In Situ Temperature Measurement Ref. No.: Version: 1.0 IESNA SUSTAINING MEMBER LCGP16030138 Date of issue: Mar. 28, 2016 Total pages: 8 Test report of In Situ Temperature Measurement Rendered to: GLL Shenfubao Industry Park, Bonded Area,Futian

More information

Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C

Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C IESNA SUSTAINING MEMBER Ref. No.: LCGP15060198 Dateof issue July 22,2015 Version 1.0 Total pages: 10 Test report of In Situ Temperature Measurement And Lumen Maintenance Projection Rendered to: LIGHT EFFICIENT

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. Project No. G101537614 Date: April 8, 2014 REPORT NO. G101537614CRT-005 TEST OF ONE LED

More information

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727 REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727 Project No. G101464624CRT-001 Date: January 17, 2104 INTERTEK REPORT NO. G101464624CRT-001 DIALIGHT REPORT NO. L13029 TEST OF ONE LSA ATEX ZONE

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101786356 Date: August 19, 2014 REPORT NO. 101786356LAX-001 TEST OF

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102671575 Date: July 27, 2016 REPORT NO. 102671575CHI-002 TEST OF ONE ROADWAY/AREA LUMINAIRE MODEL NO. APL-NW200 LED MODEL NO. SAMSUNG

More information

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK)

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK) In Situ Temperature Measurement Test Report For AOK LED Light Company Limited (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province,

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: January 24, 2017 REPORT NO. 102748333CHI-018 TEST OF ONE LED EPLOSION PROOF LIGHT MODEL NO. EPL-NW200 LED MODEL NO.

More information

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD ISTMT Test Report For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD Aotom LED Industrial Park, Qingzhuanzhu Road 268, Huanggang, Hubei, China LED Panel Light Model name(s): 22AP3235A (CLC/WLC FPL22-835-32W-130LW-UNV-DIM1-WH)

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: December 20, 2016 REPORT NO. 102748333CHI-015 TEST OF ONE T8 LED TUBE MODEL NO. T8-NW18F LED MODEL NO. HONGLI OPTO-ELECTRONIC

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: February 21, 2017 REPORT NO. 102748333CHI-024 TEST OF ONE LED WALL PACK MODEL NO. WPFC-CW70 LED MODEL NO. PHILIPS

More information

In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires In Situ Temperature Measurement Test Report For AOK LED Light Company Limited (Brand Name: ) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province,

More information

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015 Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015 Version 2.0 January, 2015 Prepared for Pacific Gas and Electric Company San Francisco, California Prepared by Energy Solutions

More information

IAS Accreditation Number

IAS Accreditation Number IAS Accreditation Number Company Name Address Contact Name Telephone +86 769 86858888 Effective Date of Scope November 2, 2017 Accreditation Standard ISO/IEC 17025:2005 TL-460 PuLongCun 69, Puxinhu Industrial

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA, INC. 5 25800 Commercentre Dr. Lake Forest, CA 92630 Mr. Jay Kogoma Phone: 949-448-4100 ELECTRICAL Valid to: December 31, 2017

More information

HEP Tech Co., Ltd. Company Profile

HEP Tech Co., Ltd. Company Profile HEP Tech Co., Ltd. Company Profile HEP Group Structure 1. HEP Tech Co., Ltd. Head office / Global sales team / R&D center 2. HEP GmbH Europe sales office / Warehouse / Europe R&D center & DEKRA certified

More information

Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant

Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant International Standards Bodies: Relevant to Lighting International Organisations International Organisation

More information

LED Reliability and Current Standards for Measurement

LED Reliability and Current Standards for Measurement LED Reliability and Current Standards for Measurement DOE SSL Workshop July, 2010 Eric Richman Pacific Northwest National Laboratories Program Name or Ancillary Text eere.energy.gov Life and Reliability

More information

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER)

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER) In Situ Temperature Measurement Test Report For SHENZHEN SUNPER OPTO CO.,LTD (Brand Name: SUNPER) 5/F,BLOK C,SANMIN INDUSTRIAL PARK,SHIYAN STREET, BAO AN DISTRICT,SHENZHEN 518108,GUANGDONG,CHINA High-Bay

More information

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination THE HIGH PERFORMANCE LED Fixture Series for General, Direct and Indirect Illumination KEY FEATURES INCLUDE: Advanced Thermal Management Industry Leading Deep Fin Heat Sinks with Aircraft Grade Aluminum

More information

LED Linear Design Highlights

LED Linear Design Highlights LED Linear Design Highlights Advanced Thermal Management Industry Leading Deep Fin Heat Sinks with Aircraft Grade Aluminum and 9 (23cm) [min] of perimeter conductive surface. Multiple Color Options Three

More information

NVLAP LAB CODE For. Shen Zhen Green Works Lighting Co., Ltd. Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China.

NVLAP LAB CODE For. Shen Zhen Green Works Lighting Co., Ltd. Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China. In Situ Temperature Measurement Test Report For Shen Zhen Green Works Lighting Co., Ltd (Brand Name: Green Works Lighting) Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China. High-bay

More information

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE: THE HIGH PERFORMANCE LED Luminaire Series for Stairwells, Bathrooms, Passageways, and General Illumination KEY FEATURES INCLUDE: Multiple Color Options Three color options ensure that the new lighting

More information

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE: THE HIGH PERFORMANCE LED Luminaire Series for Stairwells, Bathrooms, Passageways, and General Illumination KEY FEATURES INCLUDE: Multiple Color Options Three color options ensure that the new lighting

More information

Technical-Report for SL Lamp 5 W

Technical-Report for SL Lamp 5 W Technical-Report for SL Lamp 5 W Technical Report No. 68.184.17.478.01 Dated 2017-06-27 Client: Manufacturing place: Name: PHOCOS China Ltd. Address: 3F 1st Bldg. 4A Chang Yi Road, 266021, Qingdao, PEOPLE'S

More information

2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply

2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply 2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply California s High Efficacy Lighting Requirements for Residential Applications Kelly Cunningham Pacific

More information

Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service)

Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service) Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service) 2011 Underwriters Laboratories Inc. Date: Jan 6, 2012 Agenda Introduction Challenges in SSL design

More information

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory NEMA White Paper - Recommendations for Solid State Lighting Sub-Assembly Interfaces for Luminaires i Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory CORM May 8, 2009

More information

Reflector T2 and GU10 6,000 hours

Reflector T2 and GU10 6,000 hours Reflector T2 and GU1 6, hours 11watt SES E14 Small Screw Cap Equivalent to 6watt R63 information CFL Reflector and GU1 6, hours lamps offer traditional incandescent and halogen shapes and sizes, long life

More information

Fortimo LED Line High Flux Module

Fortimo LED Line High Flux Module Fortimo LED Line High Flux Module Fortimo LED line 2ft 4000lm 1R LV1 The Fortimo LED Line high flux systems consist of linear white light LED modules with high flux, high energy efficiency, and high quality

More information

Fortimo LED Line Gen2 Module

Fortimo LED Line Gen2 Module Fortimo LED Line Gen2 Module Fortimo LED Line 1ft 650lm 3R LV2 Fortimo LED Line systems are designed to replace fluorescent lighting in new luminaires. Fortimo LED Line Gen 2 systems are designed to replace

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 96 Project No. G85 Date: April 6, 5 REPORT NO. 85LAX- TEST OF ONE WALL BRACKET JELLY JAR MODEL NO. H-CGU--B LED MODEL NO. BRIDGELUX BXRC-E-C-X DRIVER MODEL

More information

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current LED Optimized Drivers 6 Watt Series Model: Series Environmental 6W Designed for use with Triac or ELV Phase Dimmers 120Vac or 230Vac/240Vac. 120Vac Version can be used without dimmer 120/208-277Vac Drive

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 963 Project No. G67677 Date: June 6, 4 REPORT NO. 67677LAX- TEST OF ONE FULL ON AT 9 BEAM ANGLE MODEL NO. RAZOR Q ZOOM RENDERED TO ELATION PROFESSIONAL 6 S.

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 963 Project No. G119188 Date: March 13, REPORT NO. 119188LAX-4 TEST OF ONE LED WASH MODEL NO. COLOUR CHORUS 4 RENDERED TO ELATION PROFESSIONAL 61 S. EASTERN

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 BUREAU VERITAS ADT (SHANGHAI) CORPORATION No.829, Xin Zhuan Road, Song Jiang District, Shanghai, China Ms. Amanda Cao (Authorized Representative) Phone: 86

More information

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range LED Optimized Drivers Model: Series Environmental 40W Designed for use with Triac or ELV Phase Dimmers 120Vac or 230Vac/240Vac. 120Vac Version can be used without dimmer 120/208-277Vac Drive Mode: PFC

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 93 Project No. G138456 Date: April, 16 REPORT NO. 138456LA-51 TEST OF ONE CYCLORAMA WALL WASH LUMINAIRE MODEL NO. TVL CYC RGBW RENDERED TO ACCLAIM LIGHTING

More information

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming Fluorescent Dimming s Hi-lume 3D Architectural Dimming Hi-lume 3D Overview 369-280f 1 03.08.12 Hi-lume 3D architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements.

More information

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services Safety Certification of Solid-State Lighting Products September 23, 2009 Todd Straka Director - Lighting Services Discussion Points for Today s Webinar Product Safety Certification Process Overview Key

More information

CONTENTS. Draft Minimum Energy Performance Standards for LED Lighting V6 14 November

CONTENTS. Draft Minimum Energy Performance Standards for LED Lighting V6 14 November CONTENTS SCOPE... 2 All Lamp Categories... 3 Non-directional LED lamps (table 1)... 3 Directional LED lamps (table 1)... 3 Linear LED lamps (table 1)... 3 Planar Luminaires, integrated battens & Troffers

More information

Annexure-I. 1. Goniophotometer and Goniospectroradiometric measurement System

Annexure-I. 1. Goniophotometer and Goniospectroradiometric measurement System Technical specifications of C-type Goniophotometer System with mirror arrangement for measurements of Photometric and Colorimetric parameters of Lamps, Luminaires and SSL Lighting Devices 1. Goniophotometer

More information

Cree XLamp MT-G MR16 Reference Design

Cree XLamp MT-G MR16 Reference Design Cree XLamp MT-G MR16 Reference Design APPLICATION NOTE CLD-AP62 REV 0 Figure 1: MR16 assembly (left: Carclo TIR optic, right: Ledil reflector optic) TABLE OF CONTENTS INTRODUCTION WWW. CREE.COM/XLAMP Introduction...

More information

ENERGY STAR Program Requirements for Residential Light Fixtures. Eligibility Criteria Version 4.2. Table of Contents

ENERGY STAR Program Requirements for Residential Light Fixtures. Eligibility Criteria Version 4.2. Table of Contents ENERGY STAR Program Requirements for Residential Light Fixtures Eligibility Criteria Version 4.2 Table of Contents Section 1: Definitions II Section 2: Qualifying Products V Section 3: Energy Efficiency

More information

This annex is valid from: to Replaces annex dated: Prolonged until

This annex is valid from: to Replaces annex dated: Prolonged until Registration : L 022 This annex is valid from: 13-09-2017 to 01-03-2018 Replaces annex dated: 13-06-2016 Prolonged until 01-09-2018 Meander 1051 6825 MJ Arnhem The Netherlands Location(s) where activities

More information

ELLA ID. High CRI, High lm/w OptoDrive LED-module

ELLA ID. High CRI, High lm/w OptoDrive LED-module ELLA ID ELLA ID High CRI, High lm/w OptoDrive LED-module Page 2 of 24 Pages for reference: Pages for reference:... 2 Introduction... 3 Short form Characteristics... 4 Wiring diagram:... 6 Accessories to

More information

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Fluorescent Dimming s Overview 1 architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements. By providing industry leading performance with a full-range of

More information

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications Lighting UniStreet simple, costeffective road-lighting range UniStreet At relatively low initial cost, the highly efficient LED-based UniStreet luminaire offers significant cost savings compared with conventional

More information

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights. CLARA AC CLARA AC Crystal CLARA AC 50 LED-modules for downlight A qualified solution to replace and exceed Halogen solutions in Downlights. No Driver is required! Page 2 of 24 Designed for downlight and

More information

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

T8 Self Ballasted UL & CSA LED TUBE RETROFITS T8 Self Ballasted UL & CSA LED TUBE RETROFITS Sept. 2011 Part Numbers T8 LED TUBE TECHNICAL SPECIFICATIONS Part Numbers LR-T8-17W-3.2-1200 LR-T8-17W-4.5-1200 LR-T8-17W-6.5-1200 LRT8-23WW-FS2 LRT8-23CW-FS2

More information

EcoSystem H-Series 347 V~ Ballast Overview

EcoSystem H-Series 347 V~ Ballast Overview Fluorescent Dimming s EcoSystemR H-Series 347 V ~ Architectural Dimming EcoSystem H-Series 347 V~ Overview 369-352e 1 06.04.12 EcoSystem H-Series digitally addressable ballasts provide a low-cost, flexible

More information

EcoSystem H-Series Ballasts

EcoSystem H-Series Ballasts Fluorescent Dimming s Eco H-Series Architectural Dimming Eco H-Series s 369266o 1 11.29.17 Eco H-Series digitally addressable ballasts provide a low-cost, flexible solution for any space in any application.

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Standards Institution of Israel Electronics

More information

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09 1. LISTING REQUIREMENTS MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09 1.1. The Luminaire shall be listed by a National Recognized Testing Laboratory (NRTL)

More information

Fluorescent Lamps - Guide for Electrical Measurements

Fluorescent Lamps - Guide for Electrical Measurements IAS Accreditation Number TL-471 Company Name UL-CCIC Company Limited Address No. 2, Chengwan Road Suzhou Industrial Park Suzhou 215122 People s Republic of China Contact Name Antonio Zhang, Laboratory

More information

Annex to the Accreditation Certificate D-PL according to ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12121-01-00 according to ISO/IEC 17025:2005 Period of validity: 24.03.2017 to 30.09.2019 Holder of certificate: STC (Dongguan)

More information

S R 8 Circular LED Engine Product Specification

S R 8 Circular LED Engine Product Specification S R 8 Circular LED Engine Product Specification Introduction The TERRALUX S R8 LED Engine is a fully integrated, self-contained, plug-and-play LED solution for lighting fixture manufacturers. Designed

More information

E10 & L9 Low Wattage Light Cone Data

E10 & L9 Low Wattage Light Cone Data E10 & L9 Low Light Cone Data 2W-A-SP 2W-A-NFL 2W-A-FL 3W-SP 3W-NFL 3W-FL 4W-SP 4W-NFL 4W-FL SERIES Toshiba LED Lighting gives you nothing but pure light. At Toshiba, we re illuminating the world by introducing

More information

ClearAccent - Affordable recessed LED spot

ClearAccent - Affordable recessed LED spot Lighting ClearAccent - Affordable recessed LED spot ClearAccent ClearAccent is an entry-level recessed spot range designed to replace halogen-based luminaires. Its attractive price and high lumen per watt

More information

Fast. Precise. Versatile. UL Lighting Sciences

Fast. Precise. Versatile. UL Lighting Sciences Fast. Precise. Versatile. UL Lighting Sciences As the world turns to LED and SSL technology as a primary source of electric light, UL Lighting Sciences continues to build upon our industry-leading technical

More information

Energy Efficient Lighting Systems

Energy Efficient Lighting Systems Energy Efficient Lighting Systems Parag Thakur, Founder Green Pyramid Energy info@greenpyramidenergy.com www.greenpyramidenergy.com Agenda Lighting Concepts Types of Lights Energy Efficient Lighting Decisions

More information

LED Panel Light E830J

LED Panel Light E830J LED Panel Light E830J Light Emission Technology www.lightemissiontech.com High energy efficiency 20W LED panel light Luminous update 1700Lm High power factor Over temperature protection High uniformity

More information

Optics & Radiometry Laboratory

Optics & Radiometry Laboratory Optics & Radiometry Laboratory Scope of accredited testing The Optics and Radiometry Laboratory is accredited by the National Association of Testing Authorities, Australia to ISO 17025 Accreditation number

More information

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable S3 Tunable Lamp Fully tunable spectrum single point source produces wide range of 9+ CRI white, pastels and saturated colors Closed-loop color point maintenance to

More information

CoreLine Batten the clear choice for LED

CoreLine Batten the clear choice for LED Lighting CoreLine Batten the clear choice for LED CoreLine Batten Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light and substantial

More information

The easiest switch to comfortable white light

The easiest switch to comfortable white light Lighting The easiest switch to comfortable white light MASTER CityWhite CDO-TT Ceramic metal halide lamp with clear tubular outer bulb shape, used in outdoor offering pleasant white light Benefits White

More information

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces Project: Notes: Type: Catalog #: Date: LED UFO HIGHBAY PT-HBA-100W SERIES APPLICATIONS Large Outdoor Large Indoor Industrial Areas Churches Swimming Pools Shopping Malls Warehouses Commercial Gymnasiums

More information

Product Compliance Andy Guest

Product Compliance Andy Guest Product Compliance Andy Guest EDA Forum November 2015 www.thelia.org.uk What do we mean by compliant in lighting? How do we know products are compliant? Its CE Marked That means its OK doesn t it? What

More information

Lighting Laboratory. Ensuring the performances and compliance of your lamps and luminaires

Lighting Laboratory. Ensuring the performances and compliance of your lamps and luminaires Lighting Laboratory Ensuring the performances and compliance of your and luminaires > Accredited tests and calibrations > Independent approach, neutral results > Compliance with all relevant standards

More information

Table of Contents. Product Description. Features. CLM-DS08 Rev 9A. Product family data sheet. Source with. Characteristics - WhiteLight Dimming...

Table of Contents. Product Description. Features. CLM-DS08 Rev 9A. Product family data sheet. Source with. Characteristics - WhiteLight Dimming... Cree LMH2 LED Modules Product family data sheet CLM-DS8 Rev 9A LMH2 Light Source with LMH2 Light Source with Product Description Features Table of Contents www.cree.com/modules Cree LED modules provide

More information

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable Project: Comments: Prepared By: Tunable, fixture produces a wide range of 90+ CRI/R9 whites from 1400K-10,000K, as well as pastels and saturated colors Closed-loop color point maintenance to

More information

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable S38 Tunable Lamp Fully tunable spectrum single point source produces wide range of 9+ CRI white, pastels and saturated colors Closed-loop color point maintenance to

More information

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS PROJECT TYPE YEAR WARRANT Y Prodigy's canopy lights offer a unique combination of energy efficiency, reliability

More information

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka Last Amended on 07.10.2015 Page 1 of 18 I. EMC Test Facility 1. Electrical and Electronic Products, Process Control Devices, Lighting Control Products, Sensing and Control Devices, Electromechanical Products,

More information

Data Sheet Version 1.0

Data Sheet Version 1.0 LED Modules - Dim To Warm Round Power of Luminus in standard and custom LED modules Data Sheet Version 1.0 Lean & Fast. Made Smarter. Design Faster use standard modules to shorten development time Easy

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Standards Institution of Israel Electronics

More information

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer - 140 - C1D1 - C2D2 - ISO 14644/FS-209E Part #: HALD-24-1X150LED-V2-140DB Page: 1 Made in the USA The HALD-24-1X150LED-V2-140DB from Larson Electronics

More information

The Commercial LED Lighting Specialist

The Commercial LED Lighting Specialist The Commercial LED Lighting Specialist JANUARY 2016 LED GLASS T8 TUBES PRODUCT CATEGORY DATA SHEET Our Service, Our People, Your Choice LED GLASS T8 TUBES LED Glass T8 Tubes Manufactured by: The range

More information

Medical LED. Superbly balanced and colour corrected LED-modules for medical use.

Medical LED. Superbly balanced and colour corrected LED-modules for medical use. Medical LED Superbly balanced and colour corrected LED-modules for medical use. OptoDrive - complete LED modules for medical luminaires With light fittings used for minor surgery, examination and other

More information

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics

More information

IEEE Wireless Personal Area Networks

IEEE Wireless Personal Area Networks IEEE 802.15 Wireless Personal Area Networks Project Title Date Submitted IEEE 802.15 Working Group for Wireless Personal Area Networks White Paper: IEEE 802.15.7 VLC Regulations 15 th July, 2010 Source

More information

TubeLine LED unit Optimised comfort with a linear LED solution

TubeLine LED unit Optimised comfort with a linear LED solution Lighting LED unit Optimised comfort with a linear LED solution Fluorescent linear lighting has traditionally been the preferred choice for customers demanding a high level of visual comfort. With excellent

More information

LED RETROFIT CONVERSION KITS

LED RETROFIT CONVERSION KITS Our LED RetroFit Conversion Kits come with a complete Gear Tray Assembly to convert older 4-foot and 8-foot T8 or T12 strip-type fixtures into energy efficient LED luminaires. High quality components and

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TÜV SÜD CERTIFICATION AND TESTING (CHINA) CO., LTD. 1 SHANGHAI BRANCH 3-13 F No. 151 Heng Tong Road Shanghai, 200 070, People's Republic of China Testing Location:

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Stafford Park 7 Telford Shropshire TF3 3BQ Contact: Mr Tariq Malik Tel: +44 (0)1952 290907 Fax: +44 (0)1952 290908 E-Mail: lab@thelia.org.uk Website: www.lialab.org.uk Testing performed at the above address

More information

CDL8 LED Architectural

CDL8 LED Architectural Project: Type: Model# CDL8 LED Architectural PRODUCT DESCRIPTION Retrofit Down lights The Luminoso 8 inch Commercial LED Downlight is damp rated, and suitable for 1-277V Input equipped with fire-rated

More information

Efficient Lighting MVE Infrastructure Status Report and Overview. Steve Coyne. Consultant, UNEP en.lighten

Efficient Lighting MVE Infrastructure Status Report and Overview. Steve Coyne. Consultant, UNEP en.lighten Efficient Lighting MVE Infrastructure Status Report and Overview Steve Coyne Consultant, UNEP en.lighten MVE needs Test Laboratory Infrastructure 2 Produc t Testin g Produc t Testin g Manufacturers Global

More information

Product Description. Features. Table of Contents. CLM-DS08 Rev 11. Product family data sheet. Source with

Product Description. Features. Table of Contents. CLM-DS08 Rev 11. Product family data sheet. Source with Cree LMH2 LED Modules Family Product family data sheet CLM-DS8 Rev 11 LMH2 Light Source with LMH2 Light Source with Product Description Features Table of Contents www.cree.com/modules Cree LED modules

More information

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths Fixture Type: Project Name: Ordering Guide Feature Code Options Description Program SAE SAE Program Series Mounting CC Concealed Cove Fixture Distribution AI Asymmetric Indirect Row Length (in feet) '

More information

LED Fire Rated Downlight

LED Fire Rated Downlight LED Fire Rated Downlight 7.5W Dimmable/Non-Dimmable Fire Rated Downlights with Emergency Option. Product Overview The Kosnic LED Fire Rated Downlight with integrated LED light engine achieves high lumen

More information

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Dimensions (111mm) 3 (76mm) (111mm) (48mm) Catalog # : Project : Prepared By : Date : S2 The sleek architectural S is designed with tooless entry features saving time and money on installation. Optimizing Industry LED technology, the S series delivers

More information

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT Retrofit Kit Suitable for Acrylic Highbays and Lowbays Suitable replacement for applications using 400W HID Instant ON/Off, no cool down time needed 120277V Application

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SHANGHAI INSPECTION AND TESTING INSTITUTE OF INSTRUMENTS AND AUTOMATION SYSTEMS CO., LTD. 103 Cao Bao Road Shanghai, 200233 People s Republic of China Mr. Xu

More information

Ledinaire Batten Simply great LED

Ledinaire Batten Simply great LED Lighting Simply great LED The Ledinaire range contains a selection of popular off-the-shelf LED luminaires that comes with the high Philips quality levels at a competitive price. Reliable, energy efficient

More information

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture PRODUCT SPECIFICATIONS Frame-in Kit HOUSING: Fire and sound-rated housing. Up to 20 minute fire rated L500 (floor-ceiling) & P500 (roof-ceiling) design. Die formed #24 gauge galvanized steel construction.

More information

BeveLED Cylinder LBRP6 Surface

BeveLED Cylinder LBRP6 Surface LBRP6 CYLINDER SURFACE CYLINDER SURFACE WITH CROSS BAFFLE /cylinders Shown with cross baffle Power and beauty are both in play with our sleek architectural cylinders. The provides industry-leading performance

More information