PRICE LIST Effective From April 2015 Last Price List 2012 GST of 6% Will Be Added GST Number :

Size: px
Start display at page:

Download "PRICE LIST Effective From April 2015 Last Price List 2012 GST of 6% Will Be Added GST Number :"

Transcription

1 PRICE LIST 2015 Effective From April 2015 Last Price List 2012 GST of 6% Will Be Added GST Number : Hokkim Controls Sdn Bhd ( D) Tel : , Jalan Alam Jaya 15, Taman Alam Jaya, Batu 9 Cheras, Selangor D.E. Malaysia. Fax : For further information, visit our website at or call Roland Chong for sales inquiry. WY Chang for technical support.

2 CONTROLS SDN. BHD. PRICE LIST 2015 Contents Page Hokkim Power Factor Regulators 1 Hokkim Earthfault & Overcurrent Relays 1 Hokkim Earth Leakage Relay & Zero Phase C.T. 2 Hokkim Voltage Protection Relays 2-3 Hokkim Phase Failure / Phase Sequence Relays 3 Hokkim Frequency Relay / Speed Sensing Relays 4 Hokkim Capacitor Relays 4 Hokkim Floatless Relays 5 Hokkim AC Current Relays 5 Hokkim DC Current Relays 6 Hokkim Sequence Control Relays 7 Hokkim Pulse Card Relays 7 Hokkim AMF Integrated Controller & Control Relays 8 Hokkim Alarm Annunciator & Relays 9 Hokkim Stepper Switches (Step Controller) 9 Hokkim Flashing, Pulse & Delay Timers 9 Hokkim Battery Chargers & Power Supplies 10 Hokkim Lamp Test Controls 10 Hokkim Special 11-pin Plug-in Relays 11 Hokkim Thermistor Probe Relays 11 Hokkim Aircraft Warning Light Relays 11 Hokkim Surge Arrestor Relays 11 Hokkim General 12 Hokkim Transducers / Transducer Selection Code 13 Hokkim PIC Series Programmable Controllers 14

3 HOKKIM POWER FACTOR REGULATORS SIRIM Test Report No. EL available upon request HL-7 7-Step Power Factor Regulator HL Step Power Factor Regulator 1, HL-7i 7-Step Power Factor Regulator with P.F Indicator HL-14i 14-Step Power Factor Regulator with P.F Indicator 1, HL-7c 7-Step Cyclic Power Factor Regulator HL-14c 14-Step Cyclic Power Factor Regulator 1, HL-7ci 7-Step Cyclic Power Factor Regulator with P.F Ind. 1, HL-14ci 14 Step Cyclic Power Factor Regulator with P.F Ind. 1, HL Step Power Factor Regulator 2, HL-20c 20-Step Cyclic Power Factor Regulator 3, HL Step Power Factor Regulator 2, HL Step Power Factor Regulator 3, HOKKIM EARTHFAULT & OVERCURRENT PROTECTION RELAYS SIRIM Test Report No. EL available upon request. EARTHFAULT RELAYS 1102 HEF-D Earthfault with Adjustable Delay Trip HEF-M Earthfault with Delay & Multiplier Override Trip HEF-T Earthfault with IDMT OVERCURRENT RELAYS 1105 HCF-D Overcurrent with Adjustable Delay Trip HCF-M Overcurrent with Delay & Multiplier Override Trip HCF-T Overcurrent with IDMT EARTHFAULT & OVERCURRENT RELAYS 1108 HEC-D Earthfault & Overcurrent with Adjustable Delay Trip 1, HEC-M Earthfault & Overcurrent with Delay & Multiplier Override Trip 1, HEC-T Earthfault & Overcurrent with IDMT 1, Price list Note : Prices are subjected to change without prior notice Page 1

4 HOKKIM EARTH LEAKAGE PROTECTION RELAY 1120 ELR-1 Earth Leakage Relay 500mA with delay ZCT-50 Zero Current Transformer 50mmf HOKKIM VOLTAGE PROTECTION RELAYS 3 Phase 3 Wire (Detects variation in the sum of the 3 phase voltages) 1201 DUV-R Under Voltage Relay DUV-D Under Voltage Relay with delay DUV-2R Under Voltage Relay with 2 contacts DUV-2D Under Voltage Relay with 2 contacts & delay DOV-R Over Voltage Relay DOV-D Over Voltage Relay with delay DOV-2R Over Voltage Relay with 2 contacts DOV-2D Over Voltage Relay with 2 contacts & delay DUO-VR Under / Over Voltage Relay with separate contacts HOKKIM COMPACT PLUG-IN VOLTAGE RELAYS 3 Phase 4 Wire (Detects variation in each of the 3 phase voltages separately) 1231 TUV-N Under Voltage Relay (8 pin plug-in type) NUV-N Under Voltage Relay (11 pin plug-in type) NUV-ND Under Voltage Relay with delay NUV-2N Under Voltage Relay with 2 contacts NUV-2ND Under Voltage Relay with 2 contacts & delay TOV-N Over Voltage Relay (8 pin plug-in type) NOV-N Over Voltage Relay (11 pin plug-in type) NOV-ND Over Voltage Relay with delay NOV-2N Over Voltage Relay with 2 contacts NOV-2ND Over Voltage Relay with 2 contacts & delay NUOV-N Under / Over Voltage Relay with separate contacts NUOV-ND Under / Over Voltage Relay with separate contacts & delay Price list Note : Prices are subjected to change without prior notice Page 2

5 HOKKIM COMPACT PLUG-IN VOLTAGE RELAYS 1 Phase 2 Wire 1271 TUV-L Under Voltage Relay (8 pin plug-in type) NUV-LD Under Voltage Relay with delay (11 pin plug-in type) NUV-2L Under Voltage Relay with 2 contacts NUV-2LD Under Voltage Relay with 2 contacts & delay TOV-L Over Voltage Relay (8 pin plug-in type) NOV-LD Over Voltage Relay with delay NOV-2L Over Voltage Relay with 2 contacts NOV-2LD Over Voltage Relay with 2 contacts & delay NUOV-L Under / Over Voltage Relay with separate contacts NUOV-LD Under / Over Voltage Relay with separate contacts & delay DUV-L Under Voltage Relay (Din rail type) DUV-LD Under Voltage Relay with delay DUV-2L Under Voltage Relay with 2 contacts DUV-2LD Under Voltage Relay with 2 contacts & delay DOV-L Over Voltage Relay (Din rail type) DOV-LD Over Voltage Relay with delay DOV-2L Under Voltage Relay with 2 contacts DOV-2LD Under Voltage Relay with 2 contacts & delay DUO-VL Under / Over Voltage Relay with separate contacts HOKKIM PHASE FAILURE / PHASE SEQUENCE RELAYS 1311 DSV-N Phase Failure / Phase Sequence Relay DSV-2N Phase Failure / Phase Sequence Relay with 2 contacts DAR-M Asymmetry Relay DA2R-M Asymmetry Relay with 2 contacts TSV-N Phase Failure / Phase Sequence Relay (8 pin plug-in type) TSV-NA Phase Failure / Phase Sequence Relay with adjustable trip SN170 Phase Failure / Phase Sequence Relay (11 pin plug-in type) SN172 Phase Failure / Phase Sequence Relay with 2 contacts Price list Note : Prices are subjected to change without prior notice Page 03

6 HOKKIM FREQUENCY RELAYS 1 Phase 2 Wire D-Series casing 1510 DUF Hz Under Frequency Relay DOF Hz Over Frequency Relay DOF-5S 40-60Hz Over Frequency Relay with delay release DUOF Hz Under / Over Frequency Relay Phase 2 Wire 11 Pin plug-in casing 1515 NUF Hz Under Frequency Relay NOF Hz Over Frequency Relay NUOF Hz Under / Over Frequency Relay NUOF-5S 40-60Hz Under / Over Frequency Relay (2 Phase 415V) HOKKIM ENGINE SPEED SENSING RELAYS DC 12V or 24V 1550 TFQ-1 Over Speed & Crank Cut Relay (15-800Hz W-Phase) TFQ-2 Over Speed & Crank Cut Relay ( Hz W-Phase) TFQ-3 Over Speed & Crank Cut Relay ( Hz W-Phase) TFQ-M Over Speed & Crank Cut Relay (1KHz - 8KHz Magnetic) SFQ-1 Over Speed Relay (115Hz - 800Hz W-Phase) SFQ-M Over Speed Relay (1.1KHz - 7.5KHz Magnetic Pick-up) TFQ-OS Over Speed Relay (250Hz - 1.6KHz Charger W-Phase) TFQ-OS3 Over Speed Relay (450Hz - 3.5KHz Charger W-Phase) TFQ-MS Over Speed Relay (1KHz - 7KHz Magnetic Pick-up) TFQ-CC Crank Cut Relay (35Hz - 850Hz Charger W-Phase) TFQ-CC3 Crank Cut Relay (65Hz Hz Charger W-Phase) HOKKIM CAPACITOR RELAYS Maximum 40VDC 1581 DCAP-1 Capacitor Relay 10,000uF (for AMF board) DCAP-2 Capacitor Relay 20,000uF (for AMF board) DCAP-3 Capacitor Relay 30,000uF (for AMF board) Price list Note : Prices are subjected to change without prior notice Page 04

7 HOKKIM FLOATLESS RELAYS 1602 TFR-N Single Tank Control (8 pin plug-in type) TFR-AN Single Contact High & Low Alarm Only DFR-1 Single Tank Control DFR-HB Single Tank Control with High Alarm DFR-LB Single Tank Control with Low Alarm DFR-BB Single Tank Control with High & Low Alarm DFR-2 Double Tank Control DFR-A High & Low Alarm Only with separate contacts HOKKIM AC CURRENT RELAYS 1420 DUC-2 0-2A AC Under Current Relay DUC-2D 0-2A AC Under Current Relay with delay DUC A AC Under Current Relay with 2 contacts DUC2-2D 0-2A AC Under Current Relay with 2 contacts & delay DUC-5 0-5A AC Under Current Relay DUC-5D 0-5A AC Under Current Relay with delay DUC A AC Under Current Relay DUC A AC Under Current Relay with 2 contacts DUC2-5D 0-5A AC Under Current Relay with 2 contacts & delay DUC2-8D 0-8A AC Under Current Relay with 2 contacts & delay DOC-2 0-2A AC Over Current Relay DOC-2D 0-2A AC Over Current Relay with delay DOC A AC Over Current Relay with 2 contacts DOC2-2D 0-2A AC Over Current Relay with 2 contacts & delay DOC-5 0-5A AC Over Current Relay DOC-5D 0-5A AC Over Current Relay with delay DOC A AC Over Current Relay with 2 contacts DOC2-5D 0-5A AC Over Current Relay with 2 contacts & delay DUOC-5 0-5A AC Under & Over Current Relay DCC-5 0-5A AC 5 Steps Current Detector Relay Price list Note : Prices are subjected to change without prior notice Page 05

8 HOKKIM DC CURRENT RELAYS 1460 DCD mA DC Detector DCD-02D 0-20mA DC Detector with delay DCD mA DC Detector with 2 contacts DCD2-02D 0-20mA DC Detector with 2 contacts & delay DUD-2D 0-2A DC Under Current Relay with delay DUD-5D 0-5A DC Under Current Relay with delay DOD-2D 0-2A DC Over Current Relay with delay DOD-5D 0-5A DC Over Current Relay with delay DUOD mA DC Under & Over Current Relay DC VDC to 12VDC 100mA Convertor DC-HV 12VDC to High Voltage Ignitor Relay (require HV coil) DUV-C DC Under Voltage Relay with auxiliary supply DUD A DC Under Current Relay with 2 contacts DVD-5 0-5V DC Voltage Detector Relay DVD V DC Voltage Detector Relay DMVD mV DC Voltage Detector Relay NUOV-DC 110V DC Under & Over Voltage Relay with delay Price list Note : Prices are subjected to change without prior notice Page 06

9 HOKKIM SEQUENCE CONTROL RELAYS 1702 DIR-02 Impulse Relay (2 step sequence relay) DRS-03 3 Steps Reverse Sequence Relay DRS-04 4 Steps Reverse Sequence Relay DRS-05 5 Steps Reverse Sequence Relay DRS-06 6 Steps Reverse Sequence Relay DRS-07 7 Steps Reverse Sequence Relay DRS-08 8 Steps Reverse Sequence Relay DRS-09 9 Steps Reverse Sequence Relay DRS Steps Reverse Sequence Relay 1, PSR-03 3 Steps Sequence Relay PSR-04 4 Steps Sequence Relay PSR-05 5 Steps Sequence Relay PSR-06 6 Steps Sequence Relay PSR-07 7 Steps Sequence Relay PSR-08 8 Steps Sequence Relay PSR-09 9 Steps Sequence Relay PSR Steps Sequence Relay DMS-3P 3 Steps Sequence Rotation Relay (Pressure/Temperature) DMS-4P 4 Steps Sequence Rotation Relay (Pressure/Temperature) DMS-5P 5 Steps Sequence Rotation Relay (Pressure/Temperature) DMS-6P 6 Steps Sequence Rotation Relay (Pressure/Temperature) DMS-2W 2 Steps Sequence Rotation Relay (Water Level) DMS-3W 3 Steps Sequence Rotation Relay (Water Level) DMS-4W 4 Steps Sequence Rotation Relay (Water Level) DMS-5W 5 Steps Sequence Rotation Relay (Water Level) DMS-6W 6 Steps Sequence Rotation Relay (Water Level) Note : For Indah Water Konsortium projects ; order as follows ; IWK-3W, IWK-4W etc. HOKKIM PULSE CARD RELAYS 1760 PC-06 6 Steps Pulse Card Relay PC-07 7 Steps Pulse Card Relay PC-08 8 Steps Pulse Card Relay PC-09 9 Steps Pulse Card Relay PC Steps Pulse Card Relay Price list Note : Prices are subjected to change without prior notice Page 07

10 HOKKIM AUTOMATIC MAINS FAILURE CONTROLLERS 1817 NAMF-S Compact AMF Control Relay (11-Pin) Energize Stop NAMF-R Compact AMF Control Relay (11-Pin) Energize Run HAS-CB Auto Start AMF Controller HAMF-8 Integrated AMF Controller c/w 8 alarm 1, HAMF-4 Integrated AMF Controller c/w 4 alarm 1, DAMF-5 Digital AMF Controller c/w 5 alarm 1, Alarm Extension for HAMF-8/ FARX-8 8 Way Alarm Extension Board FARX-4 4 Way Alarm Extension Board NFAR-1 1 Way Alarm Extension Relay (11-Pin) TES-T Energized Stop Timer for NAMF-R (8-Pin) Replacement Parts for HAMF-8/4 & HAS-CB 1826 MAMF-AS HAS-CB Motherboard Only MAMF-AS HAS-CB Fault Reset Relay Card MAMF/4 HAMF-4 Motherboard Only MAMF/8 HAMF-8 Motherboard Only OPR Oil Pressure Relay Card with 4 Contacts ESR Emergency Stop Relay Card FMR Fault Monitor Relay Card EST Energized Stop Timer Card MFT Mains Fail Timer Card SDT Shutdown Timer & Fuel Solenoid Card SDT4 Shutdown Timer & Fuel Solenoid with delay Card GRR Generator Run Relay Card CCR Crank Cut Relay Card OPT Oil Pressure Timer Card ASR Attempt Start Relay Card BCR Bell Cancel Relay Card LFR Lamp Flashing Relay Card FAR Fault Alarm Relay Card MFT-V Surge Arrestor Card Price list Note : Prices are subjected to change without prior notice Page 08

11 HOKKIM ALARM ANNUNCIATOR RELAYS 1803 NAR-Q Annunciator - Master Unit NAR-P Annunciator - Modular I/O Unit NAR-X Annunciator - Fault Latch Relay Unit NAR-PX Annunciator - Modular I/O Unit with Fault Latch N960 Annunciator - Modular Master & I/O Unit HOKKIM STEPPER SWITCHES (STEP CONTROLLER) 1910 TSS-3M 3 Steps Fixed Delay Switch - Master Unit TSS-1 1 Step Fixed Delay Switch - Modular Unit TSS-2 2 Steps Fixed Delay Switch - Modular Unit TSS-3 3 Steps Fixed Delay Switch - Modular Unit HSS-4M 4 Steps Adjustable Delay Switch - Master Unit HSS-8M 8 Steps Adjustable Delay Switch - Master Unit HSS-4 4 Steps Adjustable Delay Switch - Modular Unit HSS-8 8 Steps Adjustable Delay Switch - Modular Unit One Master Unit required, with appropriate number of Modular units to suit requires steps. HOKKIM FLASHING, PULSE & DELAY TIMERS 2100 TFS-1 Fixed Cycle Flasher TFS-2V ON-OFF Variable Cycle Flasher TMK-F ON-Pulse at Power OFF TMK-N ON-Pulse at Power ON TMK-NF ON-Pulse at Power ON & OFF TDF-C Fixed Delay Off Timer Through Contacts TDF-V Adjustable Delay Off Timer Through Contacts NFS-V Adjustable Cycle Flasher NFS-VA Adjustable Cycle Flasher c/w External Adjustment Pot Price list Note : Prices are subjected to change without prior notice Page 09

12 HOKKIM BATTERY CHARGERS & POWER SUPPLIES 2201 SBC A/12VDC Battery Charger (12V - 15V Adjustment) SBC A/24VDC Battery Charger (24V - 30V Adjustment) HBC3-12 3A/12VDC Battery Charger (12V - 15V Adjustment) HBC3-24 3A/24VDC Battery Charger (24V - 30V Adjustment) SBC A/12VDC Battery Charger (12V - 15V Adjustment) SBC A/24VDC Battery Charger (24V - 30V Adjustment) SBC A/12VDC Battery Charger (12V - 15V Adjustment) 1, SBC A/24VDC Battery Charger (24V - 30V Adjustment) 1, SBC A/24VDC Battery Charger (24V - 30V Adjustment) 1, SBC A/24VDC Battery Charger (24V - 30V Adjustment) 2, SBC A/48VDC Battery Charger (48V - 60V Adjustment) 6, SBC A/48VDC Battery Charger (48V - 60V Adjustment) 12, Replacement Parts 2225 HBC3-12 3A/12VDC Battery Charger Controller Card HBC3-24 3A/24VDC Battery Charger Controller Card SBC x 4,700uF 25V Capacitor Set SBC x 10,000uF 50V Capacitor Set SBC x 4,700uF 25V Capacitor Set SBC x 10,000uF 50V Capacitor Set Wrong polarity connection to battery will cause the capacitors to bulge or explode. HOKKIM LAMP TEST CONTROLS 2240 NDC Way 1A Diodes for DC Lamp Test (common +ve) NNC Way 1A Diodes for DC Lamp Test (common -ve) NDC nos. 1A 1000V Diodes NDC Way 3A Diodes for DC Lamp Test (common +ve) T1A-4 4 nos. 1A 1000V Diodes TDC1-7 7 Way 1A Diodes for DC Lamp Test (common +ve) TNC1-7 7 Way 1A Diodes for DC Lamp Test (common -ve) DA8 8 nos 1A 1000V Diodes DA15P 15 Way 1A Diodes for DC Lamp Test (common +ve) NLT-T 9 Way AC240V Lamp Test Unit Price list Note : Prices are subjected to change without prior notice Page 10

13 HOKKIM SPECIAL 8-PIN PLUG-IN RELAYS 3011 TR-22L 2 Changeover Contacts (Low Voltage Release) TR-22D 2 Changeover Contacts (300mS Delay Release) TR-22FS 2 Changeover Contacts (1 Contact Fast, 1 Contact Slow) TR-RC 4 nos. Built In 16mA RC (Resistor Capacitor) Network HOKKIM THERMISTOR PROBE RELAYS 4098 DTR-A Thermistor Probe Relay (Adjustable 2.3KΩ - 3.3KΩ) DTR-B Thermistor Probe Relay (Fixed 2.8KΩ) DTR-C Thermistor Probe Relay (Adjustable 0.5KΩ - 1.5KΩ) DTR-D Thermistor Probe Relay (Adjustable 1.3KΩ - 2.3KΩ) DTR-E Thermistor Probe Relay (Adjustable 2.5KΩ - 4.5KΩ) DTR-F Thermistor Probe Relay (Adjustable 2.5KΩ - 6.5KΩ) HOKKIM AIRCRAFT WARNING LIGHT RELAYS 4109 TAW-20L 20W Aircraft Warning Light Relay c/w Alarm Contact TAW-40L 40W Aircraft Warning Light Relay c/w Alarm Contact TAW-60L 60W Aircraft Warning Light Relay c/w Alarm Contact TAW-75L 75W Aircraft Warning Light Relay c/w Alarm Contact TAW-100L 100W Aircraft Warning Light Relay c/w Alarm Contact Rated voltage 240VAC, state lamp wattage and voltage when ordering customize unit. HOKKIM SURGE ARRESTOR RELAYS Surge Protection For Control Equipments & Relays. Require 5A Control Fuses 6551 MOV-1PNE Surge Arrestor Relay (1 Phase, Neutral & Earth) MOV-3PE Surge Arrestor Relay (3 Phase & Earth) MOV-3PN Surge Arrestor Relay (3 Phase & Neutral) MOV-3PNE Surge Arrestor Relay (3 Phase, Neutral & Earth) Price list Note : Prices are subjected to change without prior notice Page 11

14 HOKKIM GENERAL CONTROL & PROTECTION RELAYS 4104 DMD-A Moisture Detector Relay (Adjustable 10KΩ - 100KΩ) NPT-100 PT-100 Probe Relay for Submersible Pump (50 0 C C) NPT-150 PT-100 Probe Relay for Motor Winding (50 0 C C) DRP-D Reverse Power Relay (1Ph2W, 3Ph3W, 3Ph4W) (Recommended 1Ph2W. L-N 240VAC) 4120 CGC-1 Gen-Set Cranking Card PNP (Fire Fighting Board) CGC-2 Gen-Set Cranking Card NPN (Fire Fighting Board) NCR-1 Gen-Set Cranking relay (1-9 Attempts Selection) DIPP Integral Pump Protection Relay (Thermal, Moisture, PT-100.) DPR-N1 Phase Synchronizing Relay DPR-N2 Phase Synchronizing Relay with 2 Contacts TVI 10 LED Battery Voltage Indicator TPVMR-D Precision DC Voltage Monitoring Relay with Delay TRD-1 Telephone Ring Detector TOH-1 Telephone Off-Hook Detector AVR-C Automatic Voltage Regulator for Gen-Set (15A max) HAC-16 Re-triggerable Alarm Card TPM-2 Twin Fault Relay Driver LDL-1CR 002A Controller Relay LDL-1PC 001A Remote Signal Relay DAV-S Automatic Voltage Selector Relay DPP-U Pilot Protection Unit TRS-R Set Reset Relay (Memory Latch) HMC-1 DC Motor Speed Controller DPW-5 5 Way Proportional Solenoid Valve Controller PVC-1 Single Proportional Solenoid Valve Controller PVC-2 Double Proportional Solenoid Valve Controller TIS-2 Impact Sealer Relay (Plastic Bag Sealer) SSR-3A 3A Solid State Relay with Zero Crossing DPR-2 Proximity Sensor Pulse Relay KM6ENA DC Rectifier for contactor coil TVS-2 Voltage Sensing Relay for welding set 12VDC TVS-3 Voltage Sensing Relay for induction motor 240VAC TTR-1 Toggle Relay through contacts HRA-1 Run Alarm Relay for machine operation DSF-2P 2 Pole Safety Relay DSF-4P 4 Pole Safety Relay NPVM-2RD Precision DC Voltage Monitoring Relay c/w 2 cont. & delay Price list Note : Prices are subjected to change without prior notice Page 12

15 HOKKIM TRANSDUCERS 5000 U / US / UL All Transducers Hokkim transducers has a wide range of signal inputs and signal outputs. To order please specify the Signal Input Code, Signal Output Code & Supply Voltage from the table below; Example; US07c 240VAC. Signal Input 0-5A (Code 07), Signal Output 4-20mA (Code c). I/O signals are Not Isolated for U models, Isolated for US models, UL are for Loop Powered. TRANSDUCER SELECTION CODES Code Signal Input Code Signal Input Code Signal Output Vac (1Ph2W) Vac (1Ph2W) a 0-10Vdc Vdc Vdc b -10Vdc to +10Vdc mVdc mVdc c 4-20mAdc Vdc Vdc d 1-5Vdc Vdc Vdc e 2-10Vdc KHz Pulses Hz f 2-11mAdc Aac Vdc g 0-20mAdc mAdc Aac h 0-1mAdc 09 1KΩ to100kω POT KHz Pulses i 0-5Vdc Vdc Vac (1Ph2W) j 0-50mAdc Vdc 46 3mA-0mA k 0-1Vdc Vac (1Ph2W) Vdc Dual l 0-2.5Vdc Aac 48 20KΩ-2MΩ 2-wire m 0-2mVdc Vac (3Ph3W) Ω 2-wire n 0-30Vdc Vdc mAdc o 0-100KHz Pulses mVdc Vdc p Relay Contacts Vdc 52-10Vdc to +10Vdc q 0-2KHz Pulses Aac Adc r 2-20mAdc mVdc Vdc s 0-10mAdc Vdc KΩ 2-wire t 0-24Vdc 1A KΩ 2-wire 56 - u 4-20mAdc Ω 2-wire 57 - v 0-230Vac Vdc 58 - w 0-24Vdc Proportional o C PT x mVdc Hz (Aux. Direct) 60 - y 0-5KHz Pulses Vac (Aux. Direct) 61 - z 0-12Vdc Vdc 62 - a o C PT b Adc 64 - c Adc 65 - d Adc 66 - e o C PT f mVdc 68 - g mVdc 69 - h mAdc 70 - i1 - Price list Note : Prices are subjected to change without prior notice Page 13

16 HOKKIM PIC SERIES PROGRAMMABLE CONTROLLER 55xx PIC55 Series Maximum 13 Inputs / / IO 52xx PIC22 Series Maximum 22 Inputs / / IO 53xx PIC33 Series Maximum 33 Inputs / / IO Example 1 : Requirement is for 1 input, 4 outputs. Then the stock number is 5505 and the model is PIC The price will be x 5 = RM Example 2 : Requirement is for 5 inputs, 6 outputs. Then the stock number is 5511 and the model is PIC The price will be x 11 = RM1, Example 3 : Requirement is for 8 inputs, 12 outputs. Then the stock number is 5220 and the model is PIC The price will be x 20 = RM2, Example 4 : Requirement is for 14 inputs, 16 outputs. Then the stock number is 5330 and the model is PIC The price will be x 30 = RM3, Initially you have to let us know your requirements and we will prepare the specifications for your approval. Once you sign to approve the specifications, we will begin programming and each unique program will be assigned a new program number e.g. P061. Refer to our website hokkim.com for more programs. Price list Note : Prices are subjected to change without prior notice Page 14

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 INTRODUCTION Thank you for purchasing the Hokkim Integrated Automatic Mains Failure Control Board model HAMF- 8 or HAMF-4. We shall

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input April 2006 SCR-SCRF Utility & General Industry Switchgear Alarm Systems Engine Starting Railroad Emergency

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

DGC-500 DIGITAL GENSET CONTROLLER

DGC-500 DIGITAL GENSET CONTROLLER DGC-500 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-500) offers a low cost microprocessor based integrated alternative for the control and monitoring of small to medium sized

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor 4 Zones, 8 Sensors Features Four independent arc fault tripping zones 1 or 2 arc fault sensors per zone allowing up to 8 arc fault sensors per module Trip indication

More information

M2000 Engine Controller

M2000 Engine Controller M2000 Engine Controller Integrated control and protection of diesel and gas engines for all purposes Especially suited for auxiliary generator sets 1 IN OPERATION 1 2 STARTFAIL 2 3 OVERSPEED RPM FAIL 3

More information

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where

More information

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input SCR/SCRF SERIES FLOAT BATTERY CHARGERS Industry s First Choice for Time-Tested Proven Reliability Single-Phase Input Three-Phase Input Applications for: Utility & General Industry Switchgear Engine starting

More information

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control File: S8485 Wiring Diagram This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control Panel. The operation of this product is intended for indoor

More information

Release Control Fire Alarm Systems

Release Control Fire Alarm Systems SYSTEM ABORT PUSH AND HOLD COIL SUPERVISION MODULE (2 AMP) 2081-9046 RED INSTALLATION INSTRUCTIONS 574-437 REV YEL NAC+ MAINTAIN 1/4" SEPARATION BETWEEN POWER LIMITED (RED/) AND NONPOWER S LIMITED (YEL/)

More information

FLOAT BATTERY CHARGERS

FLOAT BATTERY CHARGERS FLOAT BATTERY CHARGERS UNFILTERED SCR SERIES FILTERED SCRF SERIES SINGLE PHASE INPUT THREE PHASE INPUT Applications for: UTILITY & GENERAL INDUSTRY Switchgear Engine Starting Emergency Lighting Alarm Systems

More information

ESSEX ENGINEERING CORPORATION

ESSEX ENGINEERING CORPORATION WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input SCR/SCRF SERIES FLOAT BATTERY CHARGERS Industry s First Choice for Time-Tested Proven Reliability Single-Phase Input Three-Phase Input Applications for: Utility & General Industry Switchgear Engine starting

More information

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules Application The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors and manual call points,

More information

INPUT / OUTPUT MINI MODULES

INPUT / OUTPUT MINI MODULES INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling

More information

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR Solid State Relays SOLITRON MIDI Current Sensing Type, R AC semiconductor contactor Integrated current monitoring Zero switching (1A) Direct copper bonding (DCB) technology LED-indication Cage clamp output

More information

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels CF5000, MF5000 and FXP5000 Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels 16 zone panels Contents PANEL INSTALLATION...3 Installation...3 PANEL WIRING... 3 Mains power

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

Monitoring Devices 11/1

Monitoring Devices 11/1 11/4 Introduction 11/6 5TE5 8 light indicators 11/7 4AC3 0, 4AC3 1 bells, buzzers 11/7 5TT3 46 fault signaling units 11/8 7LQ2 1, 5TT3 3 dusk switches 11/9 7LQ2 0 temperature controllers 11/9 5TT3 170

More information

Conventional Leaflets

Conventional Leaflets Conventional Leaflets Panels Last updated October 1999 Make leaflet selection by clicking on appropriate bookmark Return to Menu Installation and Basic Commissioning guide for the range of 1,2,4 and 8

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

4 & 8-POINT ANNUNCIATORS Instruction Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual 4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal

More information

I/O ZONE 560/583 AND OPERATION MANUAL

I/O ZONE 560/583 AND OPERATION MANUAL UPM I I/O ZONE 560/583 INSTALLATION AND OPERATION MANUAL 1 UNIT PROTECTION MODULE HARDWARE OPERATION IMPORTANT: This manual is for UPM board part numbers 8733 800 259. See controller label as shown in

More information

HTC-915-CONT. Heat-Trace Control system

HTC-915-CONT. Heat-Trace Control system Heat-Trace Control system Product overview The Raychem HTC-915 system is a compact, full-featured microprocessor-based single-point heat-trace controller. The HTC-915-CONT provides control and monitoring

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation

More information

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual Technical Manual Type EC-2 Engine Control Unit 4189340232D DEIF A/S Technical Manual DEIF A/S Tel.: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fax: (+45) 9614 9615 Denmark E-mail: deif@deif.com Contents

More information

VAMP 120 & 121. Arc flash detection units. Product picture

VAMP 120 & 121. Arc flash detection units. Product picture Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

AO Annunciator Module

AO Annunciator Module General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,

More information

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Operations Manual. Motion Detector Module Model ZS10

Operations Manual. Motion Detector Module Model ZS10 Motion Detector Module Model ZS10 The must be referred to for correct installation. Failure to comply with the shall void all warranties and liabilities. Overview The ZS10 Motion Detector Module is an

More information

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power

More information

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms,

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK Installation Manual AQM-20 12vdc/24vdc Series Power Supplies AQM20 Supervised Power Supply/Charger 12vdc 20Amp/24vdc 10Amp Life Time Warranty Quality Manufactured in the USA AQM20 Features: The AQM20 has

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management Reyrolle Protection Devices 7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management 7XG3120 - Arc Fault Monitor Relay The over-current caused by an arc is, due to its resistance, lower than the over-current

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

Operating Instructions

Operating Instructions D-TEK Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product

More information

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms, 50/60

More information

ESP TECHNOLOGIES LIMITED

ESP TECHNOLOGIES LIMITED Alarm Technology ESPAN-01 Series Annunciator System Combination type User Manual (Rev. 1) ESP TECHNOLOGIES LIMITED www.esptechno.com Content Page Introduction 2 General Description 2 Overview - Annunciator

More information

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC Operating Instructions We have designed the new MVP-D-TEK vehicle loop detector with the following objectives in mind: 1. Compact package to allow

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option Description of options Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M 4189340401D SW 1.4X.X Description of option Functional description DEIF A/S Parameter list DEIF A/S,

More information

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd. F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

DTA. Motor thermistor relay. Benefits. Description

DTA. Motor thermistor relay. Benefits. Description DTA Motor thermistor relay Description DTA71 and are precise Motor thermistor monitoring relays. They can monitor up to 6 motor temperatures through the motor internal temperature. PTCs are connected in

More information

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts Figure 1Document: SPEC-112 Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts construction requirements of UL approved Class H (180 C) insulation system. Transformers

More information

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS TABLE OF CONTENTS 1 TABLE OF CONTENTS TABLE OF CONTENTS 1 FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2

More information

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES Data Sheet 260.8 TIMER START I / O LOW-V SET TIMER OUT + SUPPLY TIMING RES. FEEDBACK 2 3 4 5 6 7 V DD LOGIC OSC. & TIMING DRIVER 8 V SS 9 ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS ) Supply

More information

50A Integrated Furnace Control

50A Integrated Furnace Control Goodman White-Rodgers 0130F00005 PCBBF110 PCBBF123 50A55-743 0130F00005S PCBBF110S PCBBF123S 50A55-289 B1809926 PCBBF112 50T55-289 B1809926S PCBBF112S 50A55-743 Integrated Furnace Control INSTALLATION

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

M2000 Engine Controller

M2000 Engine Controller M2000 Engine Controller Integrated control and protection of diesel and gas engines for all purposes Especially suited for auxiliary generator sets 1 IN OPERATION 1 2 STARTFAIL 2 OVERSPEED R.P.M. FAIL

More information

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS PAGE 2 of 24 AUDIO/VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1.0 CONTENTS PAGE Manual introduction 4 System introduction

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL CONTENTS 1. INTRODUCTION. 3 1.1 HANDLING THE PCBS 1.2 USING THIS MANUAL

More information

Notification Appliance Circuit Module

Notification Appliance Circuit Module Notification Appliance Circuit Module D192G en Installation guide Notification Appliance Circuit Module Notices en 3 1 Notices These instructions cover the installation of the D192G Notification Appliance

More information

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU with Automatic Power Transfer Switch Contents: NOTE: The drawings included in this package are for controllers covered under our standard

More information

Ramsey Motion Monitoring Systems

Ramsey Motion Monitoring Systems Ramsey Motion Monitoring Systems 60-200 Motion Monitoring Accurate Sensing of Underspeed, Overspeed and Zero Speed Conditions on Rotating Shafts and Machinery The Ramsey Series 60-200 Motion Monitoring

More information

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design TOTAL SOLUTIONS Liquid Level Control Product Guide MATELEC innovative by design Liquid Level Control Contents Dual Pump Controllers Section 1 The Range Common Features Operating Data Control Logic Setup

More information

Electric Release Panel Wiring Tips

Electric Release Panel Wiring Tips R IPS CARBO STEEL PIPE FIRE PROTECTIO PRODUCTS Electric Release Panel Wiring Tips 30.4 VICTAULIC IS A ISO 900 CERTIFIED COMPAY Model PDRP-00 Releasing Panels are compact single enclosure units containing

More information

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy Reyrolle Protection Devices 7PG26 DAD High Impedance Current Relay Answers for energy Siemens Protection Devices Limited 2 7PG26 DAD High Impedance Circulating Current Relay Description The type DAD relay

More information

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN 04-350 Product Installation

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 031-01284-000/50A55-241 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

LC2200 Level Controller Installation and Maintenance Instructions

LC2200 Level Controller Installation and Maintenance Instructions 4025250/9 IM-P402-77 AB Issue 9 LC2200 Level Controller Installation and Maintenance Instructions LC2200 ALARM TEST >50% >100%

More information

DTA04. Motor thermistor relay. Benefits. Description

DTA04. Motor thermistor relay. Benefits. Description Motor thermistor relay Benefits High operating safety. The thresholds are determined by the Motor PTC. Beyond the specified temperature the output stops the motor/s. Save time and costs.there is no need

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147) -961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages) Measuring relays RM2I 2 module housing (single-phase alternating current) RM2U 2 module housing (single-phase alternating current) RM3I Rail DIN housing (three-phase alternating current) RM3U Rail DIN

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products 7 418 Gas Burner Controls LGA... The LGA... are used for the startup and supervision of atmospheric gas burners of small to medium capacity (without fan) in intermittent operation. The LGA... and this

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50V64-743 Integrated Furnace Control for Furnaces with Variable Fan Speed INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

Pump-Down Controller MODEL 4052

Pump-Down Controller MODEL 4052 Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down

More information

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC. M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998

More information

PSN-1000 & PSN 1000(E) Installation Manual

PSN-1000 & PSN 1000(E) Installation Manual PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass Project: Customer: Engineer: Pump Manufacturer: Submittal Document Model VPS Pressure Limiting (VFD) with Soft Start Bypass Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note:

More information

DTM Distributed Transmitter-Monitor

DTM Distributed Transmitter-Monitor DTM Distributed Transmitter-Monitor DTM10 Proximity Distributed Transmitter-Monitor (Shaft Vibration, Thrust Position and Speed) The DTM10 distributed vibration transmitter-monitor is ideal for monitoring

More information

Instruction Manual Model A

Instruction Manual Model A 706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com Instruction Manual Model 18-232A LOOP POWERED ALARM MANUAL NO. 990029 MODEL 18-232A LOOP POWERED

More information