Cat. No. H113-E1-03B E5ZN. Temperature Controller OPERATION MANUAL

Size: px
Start display at page:

Download "Cat. No. H113-E1-03B E5ZN. Temperature Controller OPERATION MANUAL"

Transcription

1 Cat. No. H113-E1-03B E5ZN Temperature Controller OPERATION MANUAL

2 E5ZN Temperature Controller Operation Manual Revised November 2005

3 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property.!danger!warning!caution Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. 1,2, Indicates lists of one sort or another, such as procedures, checklists, etc. OMRON, 2001 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. v

4 Abbreviations The following table lists the main abbreviations used in parameters, diagrams, and in the text itself. Abbreviation Meaning PV Process value SP Set point AT Autotuning EU Engineering units (See note.) ch Channel Parameter Notation Note Scaled data is expressed in C, m, g, and other engineering units. EU is used as the minimum unit for engineering units For example, the smallest unit of (m) is 0.01 (m) and 0.01 is thus one EU. The following table shows the alphabet notation used for parameter abbreviations and settings displayed on the E5ZN-SDL Setting Display Unit. a b c d e f g h i j k l m A B C D E F G H I J K L M n o p q r s t u U w x y = N O P Q R S T U V W X Y Z vi

5 TABLE OF CONTENTS PRECAUTIONS xiii 1 Intended Audience xiv 2 General Precautions xiv 3 Application Precautions xiv SECTION 1 Outline Name and Function of Parts I/O Configuration and Main Functions SECTION 2 Preparations Installation Using the I/O Section Installation Precautions SECTION 3 Temperature Control Settings Setting the Input Type Selecting Centigrade/Fahrenheit Selecting PID Control or ON/OFF Control Setting Output Specifications Setting the SP Executing ON/OFF Control Determining PID Constants: Autotuning and Manual Setup Alarm Outputs Using Heater Burnout Alarm (HBA) Starting and Stopping Control Operating Precautions SECTION 4 Settings Used Only when Required Shifting Input Values Alarm Hysteresis Setting Scaling Upper and Lower Limits (Analog Input) Executing Heating and Cooling Control Using the Event Input Setting the SP Upper and Lower Limit Range SP Ramp Function: Limiting SP Change Rate Key Protection Manual Mode Reading Temperatures for Multiple E5ZN Units Remote PV Mode Using Transfer Output vii

6 TABLE OF CONTENTS SECTION 5 Communications Communication Protocols Data Format Structure Structure of Command/Response Text Variable Area Read from Variable Area Write to Variable Area Operation Commands Setting Areas Commands and Responses Variable Area Map SECTION 6 Using the E5ZN-SDL Introduction Names of Parts on the Front Panel Setup Level Configuration and Front Panel Keys Initial Setup Examples Using Copy Mode List of Parameters SECTION 7 Parameters Conventions Used in this Chapter Protect Level Operation Level Adjustment Level Initial Setting Level Advanced Function Setting Level Communications Setting Level SECTION 8 Troubleshooting Troubleshooting Procedure Communications Errors Temperature Sensing Errors Temperature Control Errors Output Errors HB Alarm Errors Key Operations Not Functioning Error Displays viii

7 Appendices TABLE OF CONTENTS A Specifications B Sensor Input Setting Ranges/Control Ranges C ASCII Table Index Revision History ix

8 x

9 About this Manual: This manual describes how to use the E5ZN and includes the sections described below. Before using your E5ZN, thoroughly read and understand this manual in order to ensure correct use. Also, store this manual in a safe place so that it can be accessed whenever necessary. In this manual, current output models (E5ZN-2C@F03@-FLK) are referred to as analog output models, and voltage output models (E5ZN-2Q@H03@-FLK) and transistor output models (E5ZN- 2T@H03@-FLK) are referred to as pulse output models. There are now pulse output models that support new functions. The new models are called upgraded pulse output models when describing the functions added to these models. (Contact your OMRON sales representative if you are not sure about the functions supported by your E5ZN Temperature Controller.) The E5ZN Temperature Controller allows the user to perform the following: Control temperature for two channels with one Temperature Controller. The Temperature Controller can be expanded to control up to 32 channels. Use an E5ZN-SDL Setting Display Unit to set the Temperature Controller. Input infrared temperature sensors, analog voltages, thermocouples, or platinum-resistance thermometers. Select heating/cooling control in addition to standard control. Select autotuning as the tuning function. Use multi-sp and a RUN/STOP function with event inputs. Use a HBA (heater burnout alarm). Use communications. The E5ZN conforms to UL/CSA/IEC safety standards and EMC standards. Precautions provides general precautions for using the E5ZN. Section 1 describes E5ZN features, part names, and main functions. Section 2 describes mounting, wiring, and other preparatory work that must be done before the E5ZN can be used. Section 3 describes the basic settings required by the E5ZN. Section 4 describes scaling, SP ramp, and other functions to enable maximum use of the E5ZN functions. Section 5 describes performing communications for the E5ZN. Section 6 describes how to operate the E5ZN-SDL Setting Display Unit. Section 7 describes the parameters used to control E5ZN operation. Section 8 classifies problems by situation and describes the methods for checking any possible malfunctions.!warning Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the Temperature Controller, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given. xi

10 xii

11 PRECAUTIONS This section provides general precautions for using the E5ZN Temperature Controller. The information contained in this section is important for the safe and reliable application of the Temperature Controller. You must read this section and understand the information contained before attempting to set up or operate an Temperature Controller. 1 Intended Audience xiv 2 General Precautions xiv 3 Application Precautions xiv xiii

12 Intended Audience 1 1 Intended Audience 2 General Precautions This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). Personnel in charge of installing automation systems. Personnel in charge of designing automation systems. Personnel in charge of managing automation systems and facilities. The user must operate the Temperature Controller according to the performance specifications described in the operation manuals. Before using the Temperature Controller under conditions which are not described in the manual or applying the Temperature Controller to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the Temperature Controller are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms. This manual provides information for installing and operating OMRON Temperature Controllers. Be sure to read this manual before operation and keep this manual close at hand for reference during operation.!warning It is extremely important that a Temperature Controller be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying a Temperature Controller to the above mentioned applications. 3 Application Precautions!WARNING Do not touch the terminals while the power is ON. Doing so may cause an electric shock.!warning It may be necessary to install a power supply breaker to turn OFF the power supply before working on the Temperature Controller. Not turning OFF the power supply may result in electrical shock.!warning Do not allow metal fragments or lead wire scraps to fall inside this Temperature Controller. These may cause electric shock, fire, or malfunction.!warning Do not use the Temperature Controller in flammable and explosive gas atmospheres. There is danger of explosion.!warning Never disassemble, repair, or modify the Temperature Controller. Doing so may cause electric shock, fire or malfunction.!caution Set all settings according to the control target of the Temperature Controller. If the settings are not appropriate for the control target, the Temperature Controller may operate in an unexpected manner, resulting in damage to the Temperature Controller or resulting in accidents. xiv

13 Application Precautions 3!Caution Tighten the terminal screws properly. Tighten them to a torque of 0.40 to 0.56 N m.!warning To maintain safety in the event of a Temperature Controller malfunction, always take appropriate safety measures, such as installing an alarm on a separate line to prevent excessive temperature rise. If a malfunction prevents proper control, a major accident may result. Observe the following precautions when using the Temperature Controller. Use and store the Temperature Controller within the specified temperature and humidity ranges. If there is a possibility of the ambient temperature rising to a temperature above the specified temperature range, take steps, such as installing fans, to cool the E5ZN. If the Temperature Controller is installed incorrectly, heat will build up inside, shortening the life of the Temperature Controller. If heat buildup is a problem, use forced cooling, e.g., install a cooling fan. Do not touch the patterns or components on a board with your bare hands. Hold it by the case. To allow heat to escape, do not block the area around the Temperature Controller. (Ensure that enough space is left for the heat to escape.) Do not block the ventilation holes on the casing. Use the Temperature Controller within the specified power supply voltage and rated load ranges. Wire properly using the correct terminal polarity. Use the specified size of solderless terminals for wiring (M3, width 5.8 mm or less). Use the specified wire sizes for wiring. Power supply terminals: AWG22 to AWG14 (cross-sectional area of to mm 2 ), Other terminals: AWG28 to AWG16 (cross-sectional area of to mm 2 ), Length of exposed wire: 6 to 8 mm. Do not wire unused terminals. Make sure that the rated voltage is reached within 2 seconds after the power supply is turned ON. Allow a warmup period of 30 minutes. Attach a surge suppressor or noise filter to peripheral devices that generate noise (in particular, motors, transformers, solenoids, magnetic coils or other equipment that have an inductance component). When mounting a noise filter on the power supply, be sure to first check the filter's voltage and current capacity, and then mount the filter as close as possible to the E5CN. Allow as much space as possible between the Temperature Controller and devices that generate powerful high-frequency noise (e.g., high-frequency welders, high-frequency sewing machines) or surges. To reduce induction noise, separate the high-voltage or large-current power lines from other lines, and avoid parallel or common wiring with the power lines when you are wiring to the terminals. We recommend using separating pipes, ducts, or shielded lines. Install a switch or circuit breaker in a location easily accessible to the operator and label it appropriately. Do not use this Temperature Controller in the following places: Places subject to dust or corrosive gases (in particular, sulfide gas and ammonia gas) Places subject to high humidity, condensation or freezing Places subject to direct sunlight xv

14 Application Precautions 3 Places subject to vibration and large shocks Places subject to splashing liquid or oily atmosphere Places directly subject to heat radiated from heating equipment Places subject to intense temperature changes Cleaning: Do not use paint thinner or the equivalent. Use standard grade alcohol to clean the Temperature Controller. Install DIN track vertically. When mounting the Terminal Unit to the Temperature Controller, make sure that the hooks on the Temperature Controller are inserted properly into the Terminal Unit. Remove the dust sticker from the Temperature Controller after completing wiring to enable heat radiation. When you draw out the internal mechanism from the housing, never touch electric components inside or subject the internal mechanism to shock. xvi

15 SECTION 1 Outline 1-1 Name and Function of Parts External Appearance Front Panel Names Display Setting Switches I/O Configuration and Main Functions I/O Configuration Main Functions

16 Name and Function of Parts Section Name and Function of Parts External Appearance The E5ZN Temperature Controller can be mounted inside another device. RS-485 communications is a standard feature with the E5ZN, allowing monitoring of PVs and reading/writing parameters from the host. The Terminal Unit and the Temperature Controller Module can be separated, making wiring and maintenance of the E5ZN easier. Space and wiring can be reduced by using an Expansion Terminal Unit when connecting two or more E5ZN Controllers to the same host. Basic Controller Expansion Controller Terminal Unit Front Panel E5ZN Controller Module Front Panel Names 89ABCDE F Unit number switch Baud rate switch Operation indicators (LED) 2

17 Name and Function of Parts Section Display Operation Display 1,2, POWER Lit when power is ON. 2. ERROR Flashes when a memory error or an input error to either channel has occurred. 3. SD/RD (send data/receive data) Flashes during communications with the host computer. 4. OUT1, OUT2 (control output 1, control output 2) Lit when control output 1 or 2 is ON. 5. SUB1, SUB2 (auxiliary output 1, auxiliary output 2) Lit when auxiliary outputs 1 or 2 is ON. Note Setting Switches There is no display on the front panel for SUB3 and SUB4 (auxiliary output 3 and auxiliary output 4) of analog output models. Use the switches to change the communications conditions for communications with the host computer. Before using the E5ZN, match the settings to the host. Operate the switches under the following conditions only. The power supply must be turned OFF. The settings will be enabled only when the power is turned ON again. To change the switch setting, use a flat-blade screwdriver and turn the switch to the required position. Unit Number Baud Rate A unit number is set for each Temperature Controller to identify the Temperature Controllers connected to the host and to an E5ZN-SDL Setting Display Unit. The unit number is set in hexadecimal. The switch settings are 0 to F, which correspond to unit numbers 00 to 15. Setting A B C D E F Unit No Default Set a different unit number for each Temperature Controller when more than one E5ZN Temperature Controller is connected for RS-485 communications. Communications cannot be performed if the same unit number is used more than once in one system. Match the E5ZN Temperature Controller baud rate to the host baud rate. Setting Baud rate Do not use these settings. (bit/s) Default 3

18 I/O Configuration and Main Functions Section I/O Configuration and Main Functions I/O Configuration Pulse Output Models Analog Output Models Control ch1 Temperature input/ analog input CT input Controller Heating control output Cooling control output OR of Alarm 1 and HBA Control output 1 Aux. output 1 Control ch 1 Temperature input/analog input Controller Heating control output Cooling Control output 1 control output OR of Alarm 1 and Input Error Aux. output 1 Alarm 2 Alarm 3 Alarm 2 SP transfer output Alarm 3 Ramp SP transfer output PV transfer output Aux. output 3 Control ch2 Temperature input/ analog input CT input Heating Control output Cooling Control output OR of Alarm 1 and HBA Control output 2 Aux. output 2 Control ch 2 Temperature input/ analog input Heating MV transfer output Cooling MV transfer output Heating control output Cooling control output OR of Alarm 1 and Input Error Control output 2 Aux. output 2 Alarm 2 Alarm 2 Alarm 3 Communications Alarm 3 Communications SP transfer output Ramp SP transfer output PV transfer output Aux. output 4 Event input (one) Event input (one) Heating MV transfer output Cooling MV transfer output Default Note Refer to Output Allocations on page 26 for the combinations of functions that can be allocated to the control and auxiliary outputs. 4

19 I/O Configuration and Main Functions Section Main Functions Communications Functions Number of Control Points Input Sensor Types Control Output Alarms Control Adjustment Event Input HBA Note Communications according to CompoWay/F (see note) are supported and are performed through the RS-485 interface. Up to 16 E5ZN Temperature Controllers can be operated from the host. CompoWay/F is a general-purpose serial communications-based unified communications protocol developed by OMRON. CompoWay/F uses commands compatible with the well-established FINS, together with a unified frame format on OMRON programmable Controllers to facilitate communications between personal computers and components. One E5ZN Temperature Controller has two channels for controlling temperature. The following input sensors can be connected for temperature input. Both channels will use the same type of sensor. Thermocouple: K, J, T, E, L, U, N, R, S, B Infrared temperature sensor type: ES1A K (10 to 70 C), K (60 to 120 C), K (115 to 165 C), K (160 to 260 C) Platinum-resistance thermometer: Pt100, JPt100 Analog input: 0 to 50 mv The control output depends on the model as follows: Voltage output models (E5ZN-2Q@H03@-FLK): Pulse voltage output Transistor output models (E5ZN-2T@H03@-FLK): Transistor output (open collector) Current output models (E5ZN-2C@F03@-FLK): Linear current output Set the alarm type and alarm value, or set upper- and lower-limit alarms. If necessary, a more comprehensive alarm function can be achieved by setting the standby sequence, alarm hysteresis, and close in alarm/ open in alarm parameters. Optimum PID constants can be set easily by autotuning. The following functions can be achieved using the event input (one input per Temperature Controller): SP selection (multi-sp, 2 points max.) and RUN/STOP. The event input is used by both temperature control channels. A heater burnout alarm (HBA) is supported by pulse output models only. 5

20

21 SECTION 2 Preparations 2-1 Installation External Dimensions Assembling Units Using the I/O Section Terminal Arrangement Precautions when Wiring Wiring Installation Precautions Ensuring Prolonged Use Reducing the Influence of Noise Ensuring Precise Measurements Enclosure Ratings

22 Installation Section Installation External Dimensions (Unit: mm) The following diagrams show the E5ZN with a Terminal Unit attached. UNIT UNIT BPS BPS POWER POWER ERROR ERROR SD/RD OUT1 OUT2 SUB1 SUB2 E5ZN SD/RD OUT1 OUT2 SUB1 SUB2 E5ZN E5ZN-SCT24S-500 Terminal Unit Note: Always use this basic E5ZN-SCT24S-500 Terminal Unit if using only one E5ZN Unit. E5ZN-SCT18S-500 Terminal Unit Note: Use the Expansion E5ZN-SCT18S-500 Terminal Unit for dense mounting with two or more Units. Use this Terminal Unit for all but the first Unit Assembling Units Joining Terminal Units Together Up to 15 Expansion E5ZN- SCT18S-500 Terminal Units can be connected to a basic E5ZN-SCT24S-500 Terminal Unit. Two Terminal Units can be connected by joining the side connector on each Terminal Unit. Side connectors 8

23 Installation Section 2-1 Attach a connector cover to the rightmost Terminal Unit. Connector cover Mounting to DIN Track Mounting the Unit Pull the hook down on the bottom, latch the top hook onto the track, push the Unit until the hook locks onto the track, and then push the hook back up to lock the Unit in place. (2) Latch the top hook onto the track (3) Push the Unit into place. (1) Lower the hook. (4) Lock the Unit in place. 9

24 Installation Section 2-1 Removing the Unit Use a flat-blade screwdriver to pull down the hook and lift the Unit from the bottom. Flat-blade screwdriver Mounting End Plates Always mount end plates to both ends of the E5ZN Temperature Controllers. up up up up For only one Temperature Controller For dense mounting of multiple Temperature Controllers 10

25 Installation Section 2-1 Mounting Bracket Mount the E5ZN Temperature Controller to DIN track. Use screws to attach the DIN track to the control panel in at least three places. PFP-50N (50 cm)/pfp-100n (100 cm) DIN Track Vertical: OK Horizontal: NG Position the DIN track vertical to the ground. Mounting the E5ZN Module Mounting the Module Line up the Module with the guides on the Terminal Unit and push firmly into place. Line up with guides and push firmly until the Module clicks into place. UNIT BPS POWER ERROR SD/RD OUT1 OUT2 SUB1 SUB2 Removing the Module Push the hooks on both ends of the Module and pull out the Module to remove it. UNIT BPS POWER ERROR SD/RD OUT1 OUT2 SUB4 SUB2 11

26 Installation Section 2-1 Covers When wiring, open the E53-COV12 Terminal Cover attached to the E5ZN- SCT24S-500 Terminal Unit or the E53-COV13 Terminal Cover attached to the E5ZN-SCT18S-500 Terminal Unit. When wiring has been completed, close the cover until it clicks shut. Both E5ZN-SCT24S-500 Terminal Units and E5ZN-SCT18S-500 Terminal Units have Terminal Covers. Terminals Covered Terminals Exposed 12

27 Using the I/O Section Section Using the I/O Section Terminal Arrangement + 19 Input power supply 24VDC - B(+) Setting Display Unit Communications A(-) 22 B(+) 23 Host communications RS A(-) E5ZN-SCT24S Refer to the E5ZN-SCT18S-500 for the layout for terminals 1 to mADC/ OUT1 0-20mADC OUT ch1 ch2 Analog-output type E5ZN-2C@F03@-FLK 4-20mADC/ 0-20mADC Event input SUB1 14 SUB Noncontact SUB2 SUB2 Contact input input COM COM + - PNP (sourcing) type E5ZN-2@P@03@-FLK CT2 ch2 16 CT1 ch Voltage-output type E5ZN-2Q@H03@-FLK Transistor-output type E5ZN-2T@H03@-FLK NPN (sinking) type E5ZN-2@N@03@-FLK VDC/ SUB3 0-5VDC - SUB VDC/ 0-5VDC Analog-output type (linear-voltage-output) E5ZN-2C@F03@-FLK E5ZN-SCT18S OUT1 8 - ch ch1 ch2 Thermocouple/infrared temperature sensor VDC 21mA OUT2 2 - ch2 Voltage-output type E5ZN-2Q@H03@-FLK ch1 Pt 12VDC 21mA ch2 7 OUT V V ch1 ch2 Analog input OUT2 ch1 ch2 Transistor-output type E5ZN-2T@H03@-FLK Precautions when Wiring Separate signal leads and power lines in order to protect the E5ZN and its lines from external noise. We recommend using solderless terminals when wiring the E5ZN. Tighten the terminal screws using a torque between 0.40 and 0.56 N m. Use the following type of solderless terminals for M3 screws. 5.8 mm max. 5.8 mm max. 13

28 Using the I/O Section Section Wiring Power Supply Inputs E5ZN-SCT24S E5ZN-SCT24S E5ZN-SCT18S-500 Note The left sides of the terminal numbers in the following diagram are on the outside of the Unit and the right sides are on the inside of the Unit. Connect to terminals 19 and 20, as shown in the following diagram. When reinforced insulation is required, connect the I/O to a device without an exposed charged section or to a device with basic insulation suitable for the maximum usage voltage of the I/O section. UL/CSA/CE Safety Standards Use a SELV power supply with an overcurrent protection function. A SELV power supply refers to a power supply with redundant I/O or with increased insulation and with an output voltage of 30 Vr.m.s and a 42.4-V peak or maximum 60 VDC. Recommended power supply: S82K CD (OMRON) or S8VS A (OMRON) To ensure the rating of Main terminal disturbance voltage for class A in EN61326, equip a noise filter (DENSEI-LAMBDA, MXB or equivalent one) to the DC power line as close to the temperature controller as possible. Connect channel 1 to terminals 10 to 12 and channel 2 to terminals 4 to 6 as follows, according to the input type: ch ch2 Thermocouple or infrared temperature sensor Connect the terminals or set the parameter according to the following instructions to prevent error indicators being lit for channels not being used. For upgraded pulse output models and analog output models: With any type of sensor, the parameter sensor error indicator used (initial setting level) can be used to prevent error indicators being lit for channels not being used. For the previous pulse output models (not upgraded): For thermocouple, infrared temperature sensor, or analog input: Form a short-circuit between terminals 5 and 6 when channel 2 is not used, or between terminals 11 and 12 when channel 1 is not used. For Pt: Connect a resistance of 100 to 125 Ω between terminals 4 and 5 when channel 2 is not used, or between terminals 10 and 11 when channel 1 is not used. Form a short-circuit between terminals 5 and 6 when channel 2 is not used and between terminals 11 and 12 when channel 1 is not used DC input power supply ch1 Pt ch2 V ch1 V + Analog input ch2 14

29 Using the I/O Section Section 2-2 Control Output 1/2 Terminals 7 and 8 are for control output 1 (OUT1) and terminals 1 and 2 are for control output 2 (OUT2) V +V mADC/ 4-20mADC/ OUT1 OUT2 OUT1 OUT2 OUT1 0-20mADC OUT2 0-20mADC 8 GND 2 GND E5ZN-SCT24S E5ZN-SCT18S-500 Control output 1 Control output 2 Pulse voltage output type E5ZN-2Q@H03@-FLK The following table shows the specifications for each output. Output Pulse voltage Transistor Control output 1 Control output 2 Transistor output type E5ZN-2T@H03@-FLK Control output 1 Control output 2 Analogue current output type E5ZN-2C@F03@-FLK Specifications 12 VDC output voltage ± 15% (PNP) Max. load current 21 ma, with short-circuit protection circuit Max. usage voltage 30 VDC, max. load current 100 ma. Max. residual voltage 1.5 V, max. leakage current 0.4 ma max. Current Current output range: 4 to 20 ma DC 0 to 20 ma DC Allowable load impedance: 350 Ω max. (See note.) Note A G32A-EA Cycle Control Unit (made by OMRON; internal load impedance: 352 Ω) can be used. The pulse voltage output (control output) is not electrically insulated from the internal circuits. When using grounded thermocouples, do not connect any of the control output terminals to the ground. If the terminals are connected to ground, unwanted current paths may result in incorrect temperature measurements. Auxiliary Outputs 1/2 Terminals 13 and 15 are for auxiliary output 1 (SUB1) and terminals 14 and 15 are for auxiliary output 2 (SUB2.) E5ZN-SCT24S SUB1 SUB COM PNP (sourcing) type E5ZN-2@P@03@-FLK SUB1 SUB2 The transistor output specifications are given below. Maximum applicable voltage: 30 VDC, maximum load current: 50 ma. Maximum residual voltage: 1.5 V, maximum leakage current: 0.4 ma COM NPN (sinking) type E5ZN-2@N@03@-FLK E5ZN-SCT18S

30 Using the I/O Section Section 2-2 CT Input CT input can be used with pulse output models only. When the heater burnout alarm is used, connect a current transformer (CT) across terminals 16 and 17 for channel 1 and terminals 16 and 18 for channel 2 (no polarity) E5ZN-SCT24S/18S CT1 CT2 ch1 17 ch2 18 Use E54-CT1 or E54-CT3 Current Transformers. Linear Voltage Output E5ZN-SCT24S/18S-500 Linear voltage output is allocated to auxiliary outputs 3 and 4 and can be used with analog output models only. Terminals 16 and 17 are for auxiliary output 3 (SUB3) and terminals 16 and 18 are for auxiliary output 4 (SUB4). SUB3 SUB DC1-5V/ DC0-5V DC1-5V/ DC0-5V Do not apply voltage to the linear voltage output terminals. Output Specifications Linear voltage output Voltage output range: 1 to 5 VDC 0 to 5 VDC Allowable load impedance: 10 kω min. 16 Event Input When event input is used, connect to terminals 3 and Contact input Non-contact input E5ZN-SCT24S/18S-500 Do not apply voltage to terminals 3 and 9. The inrush current that flows from E5ZN to the contact connected to terminals 3 and 9 is approx. 7 ma. Use event inputs under the following conditions: Contact input ON: 1 kω max., OFF: 100kΩ min. No-contact input ON: residual voltage of 1.5 V max., OFF: leakage current of 0.1 ma max. 16

31 Using the I/O Section Section 2-2 Communications When communicating with a host, connect across terminals 23 and RS-485 B(+) A( ) E5ZN-SCT24S-500 The RS-485 connection can be either one-to-one to one-to-n. Up to 16 Temperature Controllers can be connected in one-to-n systems. Keep the total cable length to 500 m maximum. Isolation The E5ZN terminals are electrically isolated in the blocks shown below. Voltage output model E5ZN-2Q@H03@-FLK Transistor output model E5ZN-2T@H03@-FLK G F A C F A C G F E D C F E D C C A B A E5ZN-SCT24S-500 E5ZN-SCT18S-500 B C A B A E5ZN-SCT24S-500 E5ZN-SCT18S-500 B Current output model E5ZN-2C@F03@-FLK G F A C F A C C A H Use shielded, twisted-pair cable (with wire sizes of AWG 28 or larger). Cable B E5ZN-SCT24S A H B E5ZN-SCT18S-500 AWG 28 or larger mm 2 or larger conductor cross-section 17

32 Using the I/O Section Section 2-2 Attach a terminator to both ends of the transmission path, including the host. The terminator specifications are as follows: Terminator 100 to 125 Ω (1/2 W) Use an RS-232C/RS-485 Converter when connecting personal computers with an RS-232C port. Recommended Adapter: K (OMRON) Recommend Interface Converter: K3SC (OMRON) (The K3SC is available in models with 100 VAC power supplies and models with 24 V, AC/DC power supplies. Specify the required type of power supply when ordering.) Adapter K RS-232C D-Sub, 9-pin (Straight, female-female) RS-232C/RS-485 Converter K3SC Terminator 100 to 125 Ω (1/2 W) 23 (B) 23(B) 24 (A) 24(A) E5ZN (No.0,1,2) E5ZN (No.3,4,5) 23(B) 24 (A) E5ZN (No.13,14,15) Terminator 100 to 125 Ω (1/2 W) When using an E5ZN-SDL Setting Display Unit, connect across terminals 21 and 22. Refer to Section 6 Using the E5ZN-SDL for information on how to use the Setting Display Unit. Setting Display Unit (E5ZN-SDL) B(+) A( )

33 Installation Precautions Section Installation Precautions Ensuring Prolonged Use Reducing the Influence of Noise Ensuring Precise Measurements Use the Temperature Controller in the following operating environment: Temperature: 10 to +55 C (with no icing or condensation) Humidity: 25% to 85% When the Temperature Controller is incorporated in a control panel, make sure that the Controller's ambient temperature (not the panel's ambient temperature) does not exceed 55 C. The life of electronic equipment like Temperature Controllers is influenced not only by the life determined by the relay switching count but also by the life of internal electronic components. The service life of components is dependent on the ambient temperature: The higher the ambient temperature becomes, the shorter the service life becomes, and vice versa. For this reason, the service life of the Temperature Controller can be extended by lowering its internal temperature. Mounting Temperature Controllers in any way other than the specified mounting method may cause heat to build up inside the Temperature Controllers, which will shorten their service life. If there is a possibility of the ambient temperature rising to a temperature above the specified temperature range, take steps, such as installing fans, to cool the E5ZN. Be sure that the cooling method in not cooling just the terminal block. If only the terminal block is cooled, measurement errors may occur. To reduce inductive noise, the leads on the Temperature Controller's terminal block must be wired separately from high-voltage/high-current power lines. Also, avoid wiring lines in parallel with or in the same wiring path as power lines. Other methods, such as separating conduits and wiring ducts or using shielded cables, are also effective. Attach a surge absorber or noise filter to peripheral equipment that generates noise (in particular, motors, transformers, solenoids, or other equipment that has a magnetic coil or other inductance component). When a noise filter is used at the power supply, first check the voltage or current, and attach the noise filter as close as possible to the Temperature Controller. Also, install the Temperature Controller as far away as possible from equipment that generates strong, high frequencies (e.g., high-frequency welders or high-frequency sewing machines) or surges. When the thermocouple leads are extended, be sure to use a compensating lead wire matched to the type of thermocouple. When the platinum resistance detector leads are extended, use a lead having the smallest resistance to equalize the resistance of the three leads. Mount to DIN track that has been installed vertical to the ground. If there is a large error in the measurement values, make sure that input compensation has been set correctly. 19

34 Installation Precautions Section Enclosure Ratings The enclosure ratings are shown in the following table. The E5ZN is not waterproof. Temperature Controller IP00 Module Terminal Units IP00 20

35 SECTION 3 Temperature Control Settings This section describes the basic functions of the E5ZN. 3-1 Setting the Input Type Input Type Selecting Centigrade/Fahrenheit Selecting PID Control or ON/OFF Control Setting Output Specifications Control Period Direct (Cooling)/Reverse (Heating) Operation Output Allocations Setting the SP Changing the SP Executing ON/OFF Control ON/OFF Control Setup Determining PID Constants: Autotuning and Manual Setup Autotuning Manual Setup Alarm Outputs Alarm Type Alarm Values Using Heater Burnout Alarm (HBA) HBA Detection Operating Conditions Calculating the Detection Current Value Starting and Stopping Control Starting Control (RUN)/Stopping Control (STOP) Operating Precautions

36 Setting the Input Type Section Setting the Input Type Input Type List of Input Types Set the input type corresponding to the sensor used. The E5ZN specifications support two types of inputs, platinum resistance thermometers and thermocouples. Refer to the following tables and set the correct value for the temperature range and the sensor used. To set the input type to a K thermocouple from 20.0 to C, use host communications or the E5ZN-SDL Setting Display Unit to set 1 as the set value for the input type. Type Input type Name Set Value Input Temperature Setup Range Platinum resistance thermometer input Platinum resistance thermometer Pt to 850 C or 300 to 1,500 F to C or to F to C or 0.0 to F JPt to C or to F to C or 0.0 to F Type Input type Name Set Value Input Temperature Setup Range Thermocouple Thermocouple K to 1,300 C or 300 to 2,300 F input to C or 0.0 to F J to 850 C or 100 to 1500 F 3 20 to C or 0.0 to F T to 400 C or 300 to 700 F to C or to F E 5 0 to 600 C or 0 to 1,100 F L to 850 C or 100 to 1,500 F U to 400 C or 300 to 700 F to C or to F N to 1,300 C or 300 to 2,300 F R 9 0 to 1,700 C or 0 to 3,000 F S 10 0 to 1,700 C or 0 to 3,000 F B to 1,800 C or 300 to 3,200 F Infrared temperature K10 to 70 C 12 0 to 90 C or 0 to 190 F sensor K60 to 120 C 13 0 to 120 C or 0 to 240 F ES1A K115 to 165 C 14 0 to 165 C or 0 to 320 F (K160 to 260 C) 15 0 to 260 C or 0 to 500 F Analog input 0 to 50 mv 16 One of the following ranges depending on the results of scaling: 1,999 to 9,999 or to Note The ES1A for K160 to 260 C has been discontinued. 22

37 Selecting Centigrade/Fahrenheit Section Selecting Centigrade/Fahrenheit Select either C or F as the temperature unit. Refer to the following table and select the value that corresponds to the desired temperature unit. The same temperature unit is used for both channel 1 and channel 2. To use C, use host communications and set 0 as the temperature unit or use the E5ZN-SDL Setting Display Unit and set c. Unit C 0 F 1 Default is 0. Setting 23

38 Selecting PID Control or ON/OFF Control Section Selecting PID Control or ON/OFF Control Either 2-PID control (PID control with two degrees of freedom) or ON/OFF control can be selected. The control method is selected by using host communications or the E5ZN-SDL Setting Display Unit to change the PID/OnOff parameter. Set the control method for channels 1 and 2 separately. Default is for PID control. 2-PID Control ON/OFF Control For PID control, the proportional band (P), integral time (I), and derivative time (D) parameters must be set. These PID constants can be set by autotuning or manual setup. In ON/OFF control, the control output is turned ON when the PV is lower than the current SP, and the control output is turned OFF when the PV is higher than the current SP (for reverse operation). 24

39 Setting Output Specifications Section Setting Output Specifications Control Period Set the output period (control period). Though a shorter period provides better control performance, we recommend setting the control period to 20 seconds or more when using a relay output for heater control (to increase the effective life of the relay). If necessary, readjust the control period according to the results of trial operation with the control period parameters set to their defaults. Use host communications or the E5ZN-SDL Setting Display Unit to set the heating control period and cooling control period parameters. Default is 2 s. The cooling control period parameter is used only in heating and cooling control. Set the control periods for channels 1 and 2 separately Direct (Cooling)/Reverse (Heating) Operation 100% Direct operation refers to control where the manipulated variable (MV) is increased for an increase in the PV (e.g.,cooling). Alternatively, reverse operation refers to control where the manipulated variable (MV) is decreased for an increase in the PV (e.g., heating). MV 100% MV 0% 0% Low temperature Set value High temperature Low temperature Set value High temperature Direct operation Reverse operation For example, when the PV (temperature) is lower than the SP (temperature) in a heating control system, the manipulated variable (MV) increases by the difference between the PV and the set value. Reverse operation is thus used in a heating control system and direct operation is used in a cooling control system. Use host communications or the E5ZN-SDL Setting Display Unit to set Direct/reverse operation to 0: Reverse or 1: Direct. Default is for reverse operation (heating). Set the direct/reverse operation for channels 1 and 2 separately. 25

40 Setting Output Specifications Section Output Allocations The E5ZN has four outputs. The following tables shows the default functions allocated to each output terminal. Name Set value Function Analog output models OUT1 (control output 1) Terminals 7 and 8 OUT2 (control output 2) Terminals 1 and 2 SUB1 (auxiliary output 1) Terminals 13 and 15 SUB2 (auxiliary output 2) Terminals 14 and 15 Pulse output models E5ZN-2Q@H03@-FLK E5ZN-2T@H03@-FLK 0 ch1 Heating control output ch1 Heating control output 1 Cooling control output (See note.) Cooling control output (See note.) 2 Alarm 1 and sensor error alarm OR output Alarm 1 and sensor error alarm OR output 3 Alarm 2 output Alarm 2 output 4 Alarm 3 output Alarm 3 output 5 ch2 Heating control output ch2 Heating control output 6 Cooling control output (See note.) Cooling control output (See note.) 7 Alarm 1 and sensor error alarm Alarm 1 and HB alarm OR output OR output 8 Alarm 2 output Alarm 2 output 9 Alarm 3 output Alarm 3 output 10 ch1 SP transfer output 11 Ramp SP transfer output 12 PV transfer output 13 Heating MV transfer output 14 Cooling MV transfer output 15 ch2 SP transfer output 16 Ramp SP transfer output 17 PV transfer output 18 Heating MV transfer output 19 Cooling MV transfer output 0 to 19 (9) Same as above. Same as above. 5 ch2 Heating control output ch2 Heating control output 0 ch1 Heating control output ch1 Heating control output 1 Cooling control output (See note.) Cooling control output (See note.) 2 Alarm 1 and sensor error alarm Alarm 1 and HB alarm OR output OR output 3 Alarm 2 output Alarm 2 output 4 Alarm 3 output Alarm 3 output 5 ch2 Heating control output ch2 Heating control output 6 Cooling control output (See note.) Cooling control output (See note.) 7 Alarm 1 and sensor error alarm Alarm 1 and HB alarm OR output OR output 8 Alarm 2 output Alarm 2 output 9 Alarm 3 output Alarm 3 output 0 to 9 Same as above. Same as above. 7 ch2 Alarm 1 and sensor error alarm OR output ch2 Alarm 1 and HB alarm OR output Note When Cooling control output for ch 1 has been set for an output, ch 1 performs heating/cooling control. When Cooling control output for ch 2 has been allocated to the output, ch 2 performs heating/cooling control. 26

E5CN Temperature Controller User s Manual

E5CN Temperature Controller User s Manual E5CN Temperature Controller User s Manual Revised July 2003 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in

More information

Temperature Controller

Temperature Controller E5AN Temperature Controller Temperature Controller OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Measuring Components Department Shiokoji Horikawa, Shimogyo-ku,

More information

E5CN-FR Limit Controller USER S MANUAL

E5CN-FR Limit Controller USER S MANUAL Cat. No. H133-E1-01 E5CN-FR Limit Controller USER S MANUAL E5CN-FR Limit Controller User s Manual Produced October 2004 iv Preface OMRON products are manufactured for use according to proper procedures

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma) TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response

More information

E5AZ E5EZ. Digital Temperature Controller. Cat. No. H205-E1-01

E5AZ E5EZ. Digital Temperature Controller. Cat. No. H205-E1-01 E5AZ E5EZ Digital Temperature ontroller User's Manual at. No. H25-E1-1 E5AZ/E5EZ Digital Temperature ontroller User s Manual Produced September 27 iv Preface The compact E5AZ/E5EZ Temperature ontroller

More information

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02 Temperature Controller Fuzzy Self-tuning Temperature Controller with Advanced PID (2-PID) Control DIN-size: 6 x 6 mm (E5AJ), 2 x 2 mm (E5BJ), 4 x 4 mm (E5CJ), 4 x 6 mm (E5EJ) Fuzzy self-tuning and Auto-tuning

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A Preface Thank you for the purchase of our Microcomputer based Temperature Indicating Controllers JCD-13A or

More information

Hardware Instruction Manual. SR Mini HG SYSTEM. High-performance Multi-point Control System IMSRM15-E4 RKC INSTRUMENT INC.

Hardware Instruction Manual. SR Mini HG SYSTEM. High-performance Multi-point Control System IMSRM15-E4 RKC INSTRUMENT INC. SR Mini HG SYSTEM High-performance Multi-point Control System SR Mini HG SYSTEM Hardware Instruction Manual RKC INSTRUMENT INC. RKC www.rkc-usa.com Distributed By (800) 576-6308 Inc, IMSRM15-E4 All Rights

More information

Digital Heater Element Burnout Detector K8AC-H

Digital Heater Element Burnout Detector K8AC-H Digital Heater Element Burnout Detector K8AC-H A high-precision Heater Element Burnout Detector compatible with a wide-range of heater control methods. Push-in terminals reduce the workload. *1 Scaling

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions

More information

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL Preface Thank you for purchasing our Digital indicating controller FCS-23A. This manual contains instructions for the mounting, functions, operations

More information

Digital Temperature Controller

Digital Temperature Controller Overview Preparations E5CSV E5CS-U Digital Temperature Controller User's anual Basic Operations Operations for Applications Parameters Appendices Cat. No. H14-E1-2 Introduction ORON products are manufactured

More information

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER 1 DCL-A DC No.DCLDCE1 2007.01 Thank you for purchasing our DIN rail mounting type indicating controller DCL-A DC. This manual contains instructions

More information

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately) Digital Panel Meter Low-cost, High-quality Digital Thermometer with Built-in Microcomputer Compact DIN-size (96 x 48 x 66 (W x H x D)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

Instruction manual Temperature Controller KT7

Instruction manual Temperature Controller KT7 Instruction manual Temperature Controller KT7 No. KT71E7 201.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure

More information

SR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC.

SR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC. SR Mini HG SYSTEM High-performance Multi-point Control System SR Mini HG SYSTEM Hardware Instruction Manual RKC INSTRUMENT INC. IMSRM15-E6 Modbus is a registered trademark of Schneider Electric. The name

More information

E5EZ-PRR. Position Proportional Controller. User s Manual. Cat. No. H200-E1-01

E5EZ-PRR. Position Proportional Controller. User s Manual. Cat. No. H200-E1-01 E5EZ-PRR Position Proportional Controller User s Manual Cat. No. H2-E1-1 Introduction E5EZ-PRR Temperature Controller Features: Thank you for choosing the OMRON E5EZ-PRR. This user manual describes E5EZ-PRR

More information

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100 INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL PREFACE Thank you for the purchase of our PLC Interface Unit CIT-200. This manual contains instructions for the mounting, functions, operations and notes when

More information

INSTRUCTION MANUAL Micro-computer based digital indicating controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTION MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E3 24.7 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

Instruction manual for DIN rail mounting type indicating controller DCL-33A

Instruction manual for DIN rail mounting type indicating controller DCL-33A Instruction manual for DIN rail mounting type indicating controller DCL-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

DIGITAL INDICATOR JIR-301-M

DIGITAL INDICATOR JIR-301-M DIGITAL INDICATOR JIR-301-M Instruction Manual Preface Thank you for purchasing our digital indicator JIR-301-M. This manual contains instructions for the mounting, functions, operations and notes when

More information

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL DIN RAIL MOUNTED INDICATING CONTOLLER DCL-A INSTRUCTION MANUAL Preface Thank you for purchasing our DIN rail mounted indicating controller DCL-A. This manual contains instructions for the mounting, functions,

More information

E3M-V. Mark Sensor. Applications

E3M-V. Mark Sensor. Applications Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy grasp

More information

TEMPERATURE CONTROL MODULE MODEL R3-TC2

TEMPERATURE CONTROL MODULE MODEL R3-TC2 INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...

More information

GCS-300 No.GCS31E

GCS-300 No.GCS31E INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller GCS-00 No.GCS1E 200.0 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

F4 Process Controller Installation and Operation Guide

F4 Process Controller Installation and Operation Guide F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance

More information

Instruction manual Micro-computer based digital indicating controller

Instruction manual Micro-computer based digital indicating controller Instruction manual Micro-computer based digital indicating controller JCS-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual.

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 PV PV AT AT OUT1 OUT2/HB A1 A2 OUT1 OUT2/HB A1 A2 MODE OUT MODE OUT GCD GCR Preface Thank you for the purchase

More information

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER DCL-A No.DCL1E5 200.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY

More information

DIGITAL INDICATING CONTROLLER. BCx2 INSTRUCTION MANUAL

DIGITAL INDICATING CONTROLLER. BCx2 INSTRUCTION MANUAL DIGITAL INDICATING CONTROLLER BCx2 INSTRUCTION MANUAL Preface Thank you for purchasing our digital indicating controller BCx2 (BCS2, BCR2, BCD2). This manual contains instructions for the mounting, functions,

More information

Intelligent Speed Dome Installation Manual. Version 1.0.0

Intelligent Speed Dome Installation Manual. Version 1.0.0 Intelligent Speed Dome Installation Manual Version 1.0.0 Table of Contents 1 INTELLIGENT SPEED DOME INSTALLATION... 1 1.1 Installation Environments... 1 1.2 Check installation space and installation location

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

DIGITAL INDICATOR DI25

DIGITAL INDICATOR DI25 DIGITAL INDICATOR DI25 Operating instructions Preface Thank you for purchasing our digital indicator DI25. This manual contains instructions for the mounting, functions, operations and notes when operating

More information

INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K

INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT PREFACE Thank you for your purchase of our Touch panel monitoring unit. This manual contains instructions for the mounting, functions, operations and

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTI MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E6 28.8 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

Digital Temperature Controllers

Digital Temperature Controllers 1 Introduction Digital Temperature Controllers User s anual E5@D 2 Preparations 3 Part Names and Basic Procedures 4 Basic Operation 5 Advanced Operations 6 Parameters 7 User Calibration A Appendices I

More information

E5CN/E5CN-U (48 x 48 mm)

E5CN/E5CN-U (48 x 48 mm) Basic-type Digital Temperature Controller /-U (48 x 48 mm) New 48 x 48-mm Basic Temperature Controller with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive Maintenance Function.

More information

MICRO CONTROLLER S Z SERIES

MICRO CONTROLLER S Z SERIES Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure

More information

CN4800 Series CONTROLLER

CN4800 Series CONTROLLER CN4800 Series CONTROLLER Operator's Manual PV SV OUT1 OUT2 ALM1 ALM2 SEL M1791/0502 Contents I. PREPARING THE OPERATION... 4 1. THE BASIC INSTALLATION PROCEDURE... 5 2. CHECK OF SPECIFICATIONS... 6 2.1

More information

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC. High Resolution Temperature Controller REX-F9000 Instruction Manual RKC INSTRUMENT INC. IM9000F01-E5 All Rights Reserved, Copyright 1999, RKC INSTRUMENT INC. Thank you for purchasing this RKC product.

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for choosing Delta DTE series temperature controller. Please read this instruction sheet carefully before using your DTE to ensure proper

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates

More information

Temperature Controller SA100. Initial Setting Manual IMR01J03-E1 RKC INSTRUMENT INC.

Temperature Controller SA100. Initial Setting Manual IMR01J03-E1 RKC INSTRUMENT INC. Temperature Controller SA100 Initial Setting Manual RKC INSTRUMENT INC. IMR01J03-E1 Modbus is a registered trademark of Schneider Electric. Company names and product names used in this manual are the trademarks

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube MOS FET Relay in module package with SPDT (1C) This model of operated by voltage (Rated input voltage is 5 VDC.) Contribute to reduce the mounting space on the print circuit board by small package Contact

More information

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad. INSTRUCTI MANUAL (EXCERPT) Digital Indicating Controller ACS-13A- /A (For Use with the Infrared Temperature Sensor RD-500) No.ACS11AE1 2011.07 The digital indicating controller ACS-13A /A is an exclusive

More information

Table of Contents SECTION PAGE

Table of Contents SECTION PAGE Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................

More information

Model Number Structure

Model Number Structure Element Burnout Detector Accurate Detection of Element Burnout Regardless of Capacities Accurately detects a burned heater element or elements incorporated by a molding machine or packing machine and outputs

More information

Multi-point Digital Controller MA900/MA901. Initial Setting Manual IMR01H03-E4 RKC INSTRUMENT INC.

Multi-point Digital Controller MA900/MA901. Initial Setting Manual IMR01H03-E4 RKC INSTRUMENT INC. Multi-point Digital Controller MA900/MA901 Initial Setting Manual RKC INSTRUMENT INC. IMR01H03-E4 !"Modbus is a registered trademark of Schneider Electric.!"Company names and product names used in this

More information

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS... SECTION Table of Contents SECTION 1 INTRODUCTION...................... 1.1 Description............................... 1.2 Features................................. 1.3 Models..................................

More information

Scale 0: 10 k Scale 50: 10 k (see note 2)

Scale 0: 10 k Scale 50: 10 k (see note 2) Water Leak Alarm/Detector Eliminate Problems Caused from Water Leakage 0 to 50 k variable operating resistance to detect virtually any liquid. Two types available: Water Leak Alarm (61F-WLA) and plug-in

More information

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0) Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /

More information

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M PHOTOELECTRIC SENSORS EFA/B_-F Special family with inverted output logic Fully compatible with previous EF family Simple installation due to compact format Wide variety of models Ordering Information EFA/B

More information

Infrared port USB. Control Output 2. (built-in) SSR outputs

Infrared port USB. Control Output 2. (built-in) SSR outputs Advanced Digital Temperature Controller / (96 x 96 mm and 48 x 96 mm) CSM DS_E A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance

More information

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE DSGH Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE Revision History Revision History Version of manual Description Date 1.0 Initial release 051025 1.1

More information

TECHNICAL BULLETIN [ 1/9 ]

TECHNICAL BULLETIN [ 1/9 ] TECHNICAL BULLETIN [ 1/9 ] [Title] Production Discontinuation of the PLC MELSEC-F Series Temperature Control Block FX2N-2LC [Date of Issue] April 2017 [Relevant Models] MELSEC-F series FX2N-2LC Thanks

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

S304 and S305 Dust Emission Monitors. User Manual. Distributor

S304 and S305 Dust Emission Monitors. User Manual. Distributor S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor Humidity Sensor Temperature/Humidity Sensor ES2-THB-N Detect Humidity within an Accuracy of ±3% in a Compact Body. Set Provides Superior Humidity Control and Temperature/ Humidity Control. Employs high-polymer-resistive

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock. Temperature Controller KXN Series INSTRUCTION MANUAL Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product. Please check whether the prouduct you purchased is the exactly same as you ordered. Before using

More information

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See NEW»»» Changes in the color of the PV show the current status. You can select between different patterns for color combinations. If a certain status occurs, the status will be displayed alternating with

More information

370, boulevard de Balmont LYON Tel Fax Web:

370, boulevard de Balmont LYON Tel Fax Web: AUTOMATISME Régulateurs de température delta DELTA développe, dessine, fabrique des composants et des équipements électronique pour les plus importants constructeurs internationaux. Fort de ses 30.000

More information

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F Temperature Controller 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes Accurate to ±0.5% of full scale Multiple temperature scale ranges allow flexibility to match application Field-selectable

More information

Three-phase Thyristor Unit. 200 V AC Type THW-A1. Instruction Manual IMR02R01-E1 RKC INSTRUMENT INC.

Three-phase Thyristor Unit. 200 V AC Type THW-A1. Instruction Manual IMR02R01-E1 RKC INSTRUMENT INC. Three-phase Thyristor Unit 200 V AC Type THW-A1 Instruction Manual RKC INSTRUMENT INC. IMR02R01-E1 Company names and product names used in this manual are the trademarks or registered trademarks of the

More information

E5CN E5CN-U E5AN E5EN

E5CN E5CN-U E5AN E5EN E5N/N-U/AN/EN Digital Temperature ontroller User's anual H134-E1-01 with 11-segment Display E5N E5N-U E5AN E5EN Digital Temperature ontroller User's anual at. No. H134-E1-01 E5N/E5N-U/E5AN/E5EN Digital

More information

UNC100 Integra Manual

UNC100 Integra Manual UNC100 Integra Manual New Generation Building Security July 30, 2014 V1.2 Copyright Notice Copyright 1995-2014 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant

More information

E5AN/E5EN (96 x 96 mm and 48 x 96 mm)

E5AN/E5EN (96 x 96 mm and 48 x 96 mm) Basic-type Digital Temperature Controller E5AN/E5EN (96 x 96 mm and 48 x 96 mm) CSM_E5AN_E5EN_DS_E_4_1 New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with Enhanced Functions and Performance.

More information

VERTEX F4 Instruction Manual

VERTEX F4 Instruction Manual VERTEX F4 Instruction Manual 02/2018 The VERTEX F4 controller 1/16 DIN is our LOW COST yet HIGH SPEC controller. Configurable on input between various thermocouples from the keypad by the user or when

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

IR Intelligent Speed Dome Installation Manual

IR Intelligent Speed Dome Installation Manual IR Intelligent Speed Dome Installation Manual Version 1.0.0 Table of Contents 1 INSTALLATION PREPARATION... 1 1.1 Basic Requirement... 1 1.2 Installation Check... 1 1.3 Cable Preparation... 1 1.3.1 The

More information

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982

More information

Installation Guide for inbiox60 Series Access Control Panel

Installation Guide for inbiox60 Series Access Control Panel Installation Guide for inbiox60 Series Access Control Panel Version: 1.0 Date: April, 2011 About This Manual This manual is a guide to installation and connection of the inbiox60 series access control

More information

Flopurge TS. Operation Manual

Flopurge TS. Operation Manual Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com

More information

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

Datasheet: K-22 LO Sensor

Datasheet: K-22 LO Sensor Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter

More information