1 DirtVec dirt separator is technically advanced, easy-to-use product with simplistic design and unmatched installability. DirtVec Dirt Separators For Heating and Cooling Systems HögforsGST
2 Please note before choosing your dirt separator: Dirt can cause several issues in heating and cooling systems. Among the most common problems are corrosion, reduced component service life and breakage, increased servicing needs and costs. Key factors: Installability Ease of use Living comfort (no excessive noise) Serviceability DirtVec dirt separator benefits: Premium components Minimized risk of corrosion Extended life cycle of components Improved heat transfer Reduced commissioning time Fast delivery time Three-year (3) warranty DirtVec operating principle and separating capability (PN10/16/25) DirtVec removes solid, heavier than water impurities (particulates) from circulation water. Inside the DirtVec unit the tank's flow volume causes the fluid's flow rate to decrease rapidly, effectively separating solid impurities and causing them to sink to the discharge chamber located at the bottom of the tank. The collected residue is thus removed from the main flow and does not cause increased pressure loss. A traditional dirt separator can typically only separate impurities larger than 300 μm (0.3 mm), but DirtVec's separating capability covers particulates as small as 5 μm (0.005mm)! In other words, the separating capability of DirtVec units is several orders of magnitude higher than that of traditional dirt separators, even covering impurities invisible to the naked eye (< 0.1 mm). The most common causes of problems in water circuits and their approximate size ranges: μm mm magnetite ,005-0,5 hemp ,02-0,07 hematite ,02-0,9 sand ,07-3 welding waste ,-5 All Rights Reserved
3 h h Dimensions DirtVec G1 1/" - G2" DirtVec DN50-DN250 DN DN H H d ØD L d ØD L DirtVec technical data G1 1/" - G2" Lf Connection size DN (internal thread) 11/" 11/2" 2" H mm h mm d (internal thread) G ½" ½" ½" ØD mm L mm Lf mm Flow rate l/s 1,0 1, 1,8 Weight kg 2,8 2,7 3,5 DirtVec technical data DN50-DN250 Connection size DN (flange DIN262) /mm (weld.) DN50 / Ø60,3 DN65 / Ø76,1 DN80 / Ø88,9 DN100 / Ø11,3 DN125 / Ø139,7 DN150 / Ø168,3 DN200 / Ø219,1 DN250 / Ø273 H mm ,120 1,31 h mm H open mm ,11 h open mm d (internal thread) G 1" 1" 1" 1" 1" 1" 1" 1" ØD mm L mm Lf mm Flow rate l/s 2,2,2 5,6 8,3 13,9 20,8 3,7 55,6 Weight weld./flange kg 9/1 9/1 17/2 17/26 2/5 2/57 89/ /183 Weight open weld./flange kg 19/2 19/2 33/0 33/2 69/81 69/83 125/17 197/229 All Rights Reserved
4 Structure 1. DirtVec units feature a manual bleeder screw, making bleeding easy. 2. Lifting lugs to facilitate lifting 3. The DirtVec's unique FoxisTube is designed to separate even the smallest dirt particles without excessively increasing flow resistance.. Frame: P235GH (EN ), External coating: RAL 703, coating thickness > 0 μm 5. Our warehouse carries connection sizes all the way up to DN250 (273mm) Both welding and flange connectors Welding: P235GH (EN ), Flange: EN (PN16 / PN25) 6. Long drain interval due to the large discharge chamber. 7. DirtVec units feature a flushing connection (½" - 1"), which allows collected residue to be removed during use All Rights Reserved
5 Equipment Standard equipment: Manual deaerator Drain valve Additional materials and sizes available on demand. IAirVec deaerator is available for deaeration applications. DirtVec DN32 - DN250 DirtVec open DN50 - DN250 For network dirt separation. Sizes DN50 DN250 available in steel with welded connections / flanges. Also available in other materials. Sizes DN32 DN50 (G11/" - G2") available in brass, threaded connections. Max. operating temperature120 C. Max. operating pressure 10bar. For network dirt separation in locations with above average precipitation. Available in steel, welded connections / flanges. Also available in other materials. Max. operating temperature120 C. Max. operating pressure 10bar. All Rights Reserved
6 Flow resistance 6 dn50 dn65 dn80 dn100 5,5 5,5 pressure drop kpa 3,5 3 2,5 2 1,5 recommended max. pressure drop level 1 0,5 0 0,0 2,5 5,0 7,5 10,0 12,5 15,0 17,5 20,0 22,5 flow rate l/s v=1 m/s 6 dn125 dn150 dn200 dn250 5,5 5,5 pressure drop kpa 3,5 3 2,5 2 1,5 recommended max. pressure drop level 1 0,5 0 0,0 10,0 20,0 30,0 0,0 50,0 60,0 70,0 80,0 90,0 100,0 110,0 120,0 130,0 10,0 flow rate l/s v=1 m/s All values are max. values.
7 Flow resistance 6 G11/ G11/2 G2 5,5 5,5 pressure drop kpa 3,5 3 2,5 2 1,5 recommended max. pressure drop level 1 0, ,5 1 1,5 2 2,5 3 3,5,5 flow rate l/s v=1 m/s All values are max. values. All values are max. values. Model indications DirtVec 50-NSW Connection, W=welded, F=flanged, G=threaded Material, S=steel, H=stainless, B=brass Model, N=normal, O=open Pipe size (dn) Product family name
8 HögforsGST International heating system expertise HögforsGST specializes in the manufacture, sale and marketing of high-quality heating systems. The company has solid experience in heating systems both domestically and in export markets. Our professionalism is based on experience in production, serial manufacture, mass tailoring and project production as well as HVAC procurement channel and logistics expertise in Finland and abroad. Our operations are based on determining requirements for sustainable business operations on the market, customer-orientedness and reliability. We are equally uncompromising in terms of our high-quality products and services. Three-year warranty and fast delivery time: All DirtVec dirt separators and components come with a three-year warranty. Our products are not only premium quality; DirtVec dirt separators are also delivered fast! Ensuring fast delivery times is a key part of our operations. HögforsGST Manufacturer: HögforsGST Oy Tel (0) , Fax +358 (0) P.O. Box 55 (Pohjukansalontie 1), FI Leppävirta, Finland info@gst.fi
Airvec. Deaerators For Heating and Cooling Systems.
www.hogfors.com Airvec deaerator is technically advanced, easy-to-use product with simplistic design and unmatched installability. Airvec Deaerators For Heating and Cooling Systems HögforsGST Please note
More informationDOMESTIC COMMERCIAL INDUSTRY AUTOMATIC DIRT SEPARATORS FOR HEATING, COOLING AND PROCESS SYSTEMS
DOMESTIC COMMERCIAL INDUSTRY AUTOMATIC DIRT SEPARATORS FOR HEATING, COOLING AND PROCESS SYSTEMS The smallest particle of dirt can cause the biggest problems Dirt in system water can cause problems and
More informationDOMESTIC COMMERCIAL INDUSTRY AUTOMATIC DEAERATORS/ DIRT SEPARATORS FOR HEATING, COOLING AND PROCESS SYSTEMS
DOMESTIC COMMERCIAL INDUSTRY AUTOMATIC DEAERATORS/ DIRT SEPARATORS FOR HEATING, COOLING AND PROCESS SYSTEMS Air and dirt prevent systems from achieving optimum levels of performance Air and dirt in system
More informationDIRTCAL - DIRTMAG dirt separator
864.07 www.caleffi.com DIRTCAL - DIRTMAG dirt separator Copyright 206 Caleffi 5462-546 -5465-5465M - NA5465 - NA5465M Series Installation, commissioning and servicing instructions Function In heating and
More informationFunction. Pressure Vessel Inspector; CRN registered Sizes 2 4
ISLIRT air and dirt separator series and N RISTR SI N ISO 900:000 ert. n M UNI N ISO 900:000 ert. n 000 LI 0/. N Replaces 0/ N unction ir and dirt separators are used to continuously remove the air and
More informationDirt and Air Separators
CX Dirt and Air Separators CX Product Overview Dutypoint CX The Dutypoint CX range of separators are designed to automatically remove dirt and air from heating, cooling and process systems, ensuring optimum
More informationDIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe
DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function
More informationInstallation, commissioning and servicing instructions
NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation
More informationDISCALDIRT deaerator-dirt separator
DISLDIR deaerator-dirt separator 6 series REDIED ISO 900 M 6 ISO 900 No. 000 0/ G replaces dp 0/0 G unction Deaerators-dirt separators are used to continuously eliminate the air and dirt contained in the
More informationCommercial product range
Commercial product range 1 Commercial Installer Brochure A4_COVER.indd 1 21/09/2017 15:21 Whether it s marketing leading filters or award-winning chemicals, we design and manufacture effective solutions
More informationAIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS
AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS CT2831.0_00 EN April 2015 * Airterm Dirt Airterm Mag * o Removes any impurity o Self-cleaning o Ensures system efficiency
More informationBrawa-Mix Thermostatic mixing valves
Technical information Tender specification: The Oventrop thermostatic mixing valve Brawa-Mix without dead zone mixes hot and cold water according to an infinitely adjustable water temperature. The thermostatic
More informationSPIROTECH BV PRESENTATION ON ENERGY EFFICIENT WET SYSTEMS
SPIROTECH BV PRESENTATION ON ENERGY EFFICIENT WET SYSTEMS 1 CORRECT DESIGN PRE-COMMISSIONING FLUSHING PRE-COMMISSIONING CHECKS COMMISSIONING SYSTEM LIFE MAINTENANCE ENERGY SAVINGS Presentation by Bryan
More informationFlamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS
WATER HEATERS, STORAGE TANKS 6 Flamco and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS 2007 edition / UK Flamco glass lined water heaters for potable and heating installations Flamco
More informationZeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology
Zeparo Cyclone Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology IMI PNEUMATEX / Air Vents, Dirt Separators and Degassing / Zeparo Cyclone Zeparo Cyclone Comprehensive
More information1592P01. for liquids in piping DN
1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type
More informationHERZ Differential Pressure Control Valve 4002
HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002
More informationHERZ Regulating valve 4002
HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN
More informationHalton Rex 600 Basic R6B - Active chilled beam
Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is: A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling.
More informationTS RD 7761 RD, 7761 RD
1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum
More informationOEM Sensors for HVAC manufacturers Heat recovery Chiller
OEM Sensors for HVAC manufacturers Heat recovery Chiller 2 Heat recovery / Chiller Typical magnetic-inductive flow sensor application Product features For determining the energy balance Measurement signal
More informationCALEFFI. dirt separator series 01137/16 NA. Replaces 01137/15 NA. Product range. Technical specifications
dirt separator 56 56 565 series REIE ISO 900 M 65 ISO 900 No. 000 LEI 07/6 N Replaces 07/5 N unction In heating and air conditioning control systems, the circulation of water containing impurities may
More informationIncrease your machine s runnability. Increase the web speed. Minimize web breaks. Improve work safety. Improve product quality.
Increase your machine s runnability Increase the web speed Minimize web breaks Improve work safety Improve product quality Save energy Increase productivity Scanner products for the entire papermaking
More informationSTEAM TRAPS
STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct
More informationThe Ultimate in Distribution Efficiency. Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator
The Ultimate in Distribution Efficiency Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator Air- and dirt-free system water through a single unit, plus hydraulic separation in a low loss
More informationAir and dirt in closed systems
Air and dirt in closed systems The best techniques for removing the smallest micro bubbles and dirt particles. White paper Flamco B.V. December 2016 Air and dirt in the system Air bubbles and dirt particles
More informationcaleffi hydronic valves page 1 of 12
caleffi hydronic valves page 1 of 12 page 2 of 12 MANUAL RADIATOR VALVES 1601811 - Series 340 1601812 - Series 341 1603748 - Seies 411 1603749 - Series 412 CONVERTIBLE RADIATOR VALVES 1601816 - Series
More informationThe Professional Choice
The Professional Choice Product Catalogue Innovation in line with your clinical requirements How do you prepare for situations that leave no room for compromise? How do you get ready for an operation
More informationSemi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual
Semi-Automatic Suction Screen Filters 3"-4 Angle Service & Maintenance Manual Safety Instructions Prior to installation or handling of the filter, read the Installation and Operation instructions carefully.
More informationGasketed and brazed plate heat exchangers
Gasketed and brazed plate heat exchangers Contents Gasketed plate heat exchangers Options Brazed plate heat exchangers Options 14 22 30 32 www.fiorinigroup.it 11 Gasketed and brazed plate heat exchangers
More informationS304 and S305 Dust Emission Monitors. User Manual. Distributor
S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...
More informationLINDOFLAMM thermal engineering.
Catalogue LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 02 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Contents. 03 All-round offering
More informationNON-SLAM DYNAMIC ARV FAF 7330
PRODUCTION STANDARTS DN50 DN250 PN 10-16 Design EN 1074-4 End Connection EN 1092-2 / ISO 7005-2 Marking EN 19 Tests EN 12266 Corrosion Protection Industrial Epoxy Features y Non-Slam Dynamic ARV to be
More informationC 9000 Polymer Quick-Acting Safety Coupler Range
C 9000 Polymer Quick-Acting Safety Coupler Range C 9000 Polymer Quick-Acting Safety Couplers ISO B Profile 9401U Page -10 9405U Page -10 9414U Page -10 9410U Page -10 9421U Page -10 9416U Page -11 9440U
More informationNew TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system
New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system TERMOVAR LOADING UNIT is a pre-fabricated,
More informationCAP SERIES SEWAGE AND WASTE WATER PUMPS
Part 8 CAP SERIES SEWAGE AND WASTE WATER PUMPS TECHNICAL SPECIFICATIONS : Turbosan CAP series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and
More informationDOMESTIC OPTIMUM PERFORMANCE IN DOMESTIC HEATING AND COOLING SYSTEMS ACCESSORIES ADDITIVES ADVICE
DOMESTIC OPTIMUM PERFORMANCE IN DOMESTIC HEATING AND COOLING SYSTEMS ACCESSORIES ADDITIVES ADVICE An efficient system means a higher level of comfort All types of houses and apartment buildings have one
More informationFilters & Centrifugal Separators
www.kaeser.com s & Centrifugal Separators Flow rates 0.8 to 8 m³/min Why use compressed air filters? On average, a compressor sucks in up to 90 million particles of dirt, hydrocarbons, viruses and bacteria
More informationE-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems
E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion
More information1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W
594 59P0 Flow switch for liquids in piping DN 0 00. QE90 Contact load / switching capacity: Nominal pressure PN5 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free
More informationBall Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass
Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate
More informationTo who it may concerns. I-Ravenna, March 11 th, 2016 HEAT EXCHANGER MAINTENANCE
To who it may concerns. I-Ravenna, March 11 th, 2016 HEAT EXCHANGER MAINTENANCE Page 2 out of 7 1 INTRODUCTION Nuova Saimar offers a highly specialized service for the maintenance of all kinds of heat
More informationSOLAR SYSTEM. We follow the sun.
SOLAR SYSTEM We follow the sun. www.ayvaz.com AYVAZ SOLAR SYSTEMS COMPLETE SOLAR CONNECTION SET Ayvaz offers a complete set to connect all mechanic components of solar systems to each other and the rest
More informationCALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB
ISL deaerator-dirt separator ISL 46-461 series RI ISO 9001 M 2164 LI 01123/17 replaces dp 01123/14 unction eaerators-dirt separators are used to continuously eliminate the air and dirt contained in the
More informationSystems for central heating
www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering
More informationPRODUCT OVERVIEW THE BEST WATER QUALITY FOR OPTIMUM PERFOR- MANCE IN HVAC SYSTEMS DOMESTIC COMMERCIAL INDUSTRY SPIRO EXCEPTIONAL GUARANTEE
PRODUCT OVERVIEW THE BEST WATER QUALITY FOR OPTIMUM PERFOR- MANCE IN HVAC SYSTEMS SPIRO EXCEPTIONAL GUARANTEE DOMESTIC COMMERCIAL INDUSTRY Effective total solutions for optimum fluid quality and maximum
More informationHeated Gas Sampling Probe PSG Basic
Heated Gas Sampling Probe PSG Basic Application The heated gas sampling probes series PSG Basic are used for continuous extractive gas analysis. They enable troublefree representative sampling of hot predominantly
More informationFLAT FLAME AND EXCESS AIR BURNERS
FLAT FLAME AND EXCESS AIR BURNERS SIDEWINDER - SW SERIES FEATURES Bulletin E303 rev04 31/01/00 Mixer body: cast iron G2 Plate: cast iron G2 Gas tube: AISI304 Pre-heated air: up to 40 Suitable for different
More informationColt CoolStream Evaporative Cooling & Ventilation System
Colt CoolStream Evaporative Cooling & Ventilation System Colt CoolStream Evaporative Cooling & Ventilation System Colt CoolStrEam Adiabatic cooling & ventilation system DeSCrIPtIoN Colt CoolStream is a
More informationNuova Saimar srl. Ravenna - Italy. Over twenty years experience in the Oil & Gas Field
Ravenna - Italy SEPTEMBER 7, 2016 Over twenty years experience in the Oil & Gas Field Our Company Nuova Saimar is a world leading company in the industrial remediation and maintenance services, thanks
More informationFire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016
Instructions for Installation, Operation and aintenance 10/2016 Installation Fire damper ETPR must be installed according to this installation manual, see pages 2-5. Operation and function testing According
More informationFan heater SWT Ceiling mounted fan heater with water heat
Fan heater heat 3 models Fan heater Ceiling mounted fan heater with water heat Application The fan heater is used for heating entrances, stores, industrial premises, workshops, sports halls, garages and
More informationSelf-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2
Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43- Type 43-2 Application Regulators for district heating supply systems, heat generators, heat exchangers, and other building
More informationInstallation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and operation instructions Solar stations SolarBloC
More informationHeat carrier temperature control point RMG CERTIFICATE
Heat carrier temperature control point RMG3-0.63 10 CERTIFICATE Purpose of temperature control point RMG3T: For adjustment of temperature of heat carrier (together with other automation elements) supplied
More informationROTARY SPRAY HEADS CATALOGUE
ROTARY SPRAY HEADS CATALOGUE Via G.Pastore 7/A - 43058 Sorbolo (PR) ITALY Tel. +39.0521.698578 - Fax +39.0521.030554 www.caggiatiinox.com - info@caggiatiinox.com Rotary head series 64 Construction: The
More informationRefrigeration Dryers TG TI Series
www.kaeser.com Refrigeration Dryers TG TI Series Flow rate. to. m³/min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains
More informationTA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water
TA-MATIC Mixing valves Thermostatic mixing valve for domestic hot water IMI TA / Potable water / TA-MATIC TA-MATIC Thermostatic mixing valve for control of domestic hot water systems in apartment blocks
More informationMagnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions
Magnetic-Inductive Flow Velocity Sensor PIT Installation and Operating Instructions Table of contents 1 IDENTIFICATION... 3 1.1 Manufacturer/supplier... 3 1.2 Product type... 3 1.3 Product name... 3 1.4
More informationThermostatic valve bodies
Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single
More informationBalancing & Control. Frese PV Compact. Differential Pressure Control Valve
Balancing & Control Frese PV Compact Differential Pressure Control Valve Balancing & Control Frese PV Compact Differential Pressure Control Frese Innovative solutions from Frese balance global HVAC systems
More informationSolar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.
Installation and service instructions for contractors VIESMANN Solar-Divicon and solar pump assembly Safety instructions Please follow these safety instructions closely to prevent accidents and material
More informationin/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)
CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used
More informationColt CoolStream Adiabatic Cooling & Ventilation System
Colt CoolStream Adiabatic Cooling & Ventilation System Colt CoolStream Adiabatic Cooling & Ventilation System Colt coolstream Adiabatic cooling & ventilation system DESCRIPTION Colt CoolStream is a natural
More informationTitus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency
Titus Air Systems TDD Series The Company Since 1986, our company has been known for delivering high quality compressed air and gas system solutions. In moving from being a local sales and service provider
More informationFor commercial & industrial systems. Large volume dirt collection capacity
For commercial & industrial systems Large volume dirt collection capacity Heating & Cooling System Protection Maintaining system efficiency and reliability in larger properties is a major challenge for
More informationH E A T E X C H A N G E R S H E A T E X C H A N G E R S. Gasketed and Welded Heat Exchangers for Every Need.
Gasketed and Welded Heat Exchangers for Every Need www.tranter.com Gasketed Plate Heat Exchangers The world's largest range of efficient heat exchangers for a wide variety of applications. The heat exchangers
More informationMikrotherm. Manual Radiator Valves With presetting
Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,
More informationAkva Lux TDP-F District heating flat station for direct heating and domestic hot water systems
Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems Akva Lux TDP-F Table of contents Akva Lux TDP-F... 1 Table of contents... 1 Safety notes... 2 Delivery...
More informationIRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems
IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems ODIS Filtration is The Heart of Every Irrigation System 12 TABLE OF CONTENTS Manifolds & Accessories... 2 Series
More informationDynalux. Floor Heating Manifolds Underfl oor heating circuit manifold
Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in
More informationF4060 RESILIENT SEATED GATE VALVES
F4060 RESILIENT SEATED GATE VALVES BS 5163 AS 2638 EN 1074 FM UL EN 1171 ISO 7259 The Keystone Figure 4060 series is a Tyco manufactured resilient seated gate valve available in a wide variety of configurations
More informationHalton CHB Active chilled beam with boost function for bulkhead installation
Halton CHB Active chilled beam with boost function for bulkhead installation Combined cooling, heating, and supply-air unit for bulkhead installation Different sizes, to meet various cooling and air-flow
More informationTechnical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT
Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT
More informationSwegon CASA. duct coils for heating. the supply air
Swegon CASA the supply air duct coils for heating Instructions for installation, operation and maintenance For design engineers, installation engineers and service personnel SDHW_c_EN m ! Important information
More informationAkva Vita Instantaneous water heater
Akva Vita Instantaneous water heater Akva Vita Table of Contents Akva Vita... 1 Table of Contents... 1 Safety notes... 2 Delivery... 2 Transport and storage... 2 Mounting... 3 Pipes connections... 4 Electrical
More informationSL EX.4.51D
GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html
More informationCondensate separators
Compressed air treatment 51 52 CKL-B SERIES ALUMINIUM CONDENSATE SEPARATORS operating pressure volume flow rate 16 bar 120 to 2850 Nm 3 /h connections 3/8 to 3 operating temp. range 1,5 to 65 C standard
More informationSteam-Atomising Desuperheater
Steam-Atomising Desuperheater Purpose & Advantages Steam-atomising desuperheaters are cooling systems for controlling the temperatures of steam and hot gases. Their task is to reduce temperatures in pipelines,
More informationSmart temperature control solutions
Smart temperature control solutions State-of-the-art heating and cooling solutions, expertise & know-how combined with top quality and superior customer service. 1 1 8 7 5 9 6 10 4 3 2 www.vexve.com Contents
More informationCrimping tool HHs-6. Art convincing solutions. Video
Hydraulic crimping tools INSTRUCTION MANUAL Crimping tool HHs-6 Art. 215765 Video 215765 1. Technical data Art. 215765 Area of application: For the creation of an electrical connection by means of compression
More informationSATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE
780EN www.caleffi.com Recess Mounted Heat Interface Unit - SATK series SATK0-60 series INSTRUCTIS FOR INSTALLATI, COMMISSIING AND MAINTENANCE Function The SATK series HIU allows independent control of
More informationNKW. Heater series HEATERS
HEATERS Heater series Applications Duct electrical heaters are designed for heating of supply air in rectangular ventilating system and are applicable in supply or supply and exhaust units. Design The
More informationENTROPIE boiler TT300
ENTROPIE boiler TT300 20 60 MW 160 о С 16 bar Сontents Field application TT300 boilers... 82 Operation of ENTROPIE boiler TT300... 82 Boiler diagram...... 83 Diagram of boiler TT300... 84 Technical characteristics...
More informationVIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l
Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these
More informationFlush individual room control for floor heating systems
Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control
More informationThermostatic valves with radiator connection systems
Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator
More informationAkva Vita TDP District heating flat station for direct heating and domestic hot water systems
Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP Table of contents Akva Vita TDP... 1 Table of contents... 1 Safety notes... 2 Delivery... 2 Transport
More informationTA-MATIC
TA-MATIC 3400 11-5-15 Thermostatic mixing valve for domestic hot water 2007.06 Technical description Application: Domestic hot water systems Function: The TA-MATIC 3400 is intended mainly as a central
More informationAkva Vita TDP-F District heating flat station for direct heating and domestic hot water systems
Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F Table of contents Akva Vita TDP-F...1 Table of contents...1 Safety notes...2 Delivery...2
More informationThe Professional Choice
The Professional Choice Product Catalogue Innovation in line with your clinical requirements How do you prepare for situations that leave no room for compromise? How do you get ready for an operation
More informationThe Professional Choice
The Professional Choice Product Catalogue Innovation in line with your clinical requirements How do you prepare for situations that leave no room for compromise? How do you get ready for an operation
More informationHERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien
HERZ-Thermostatic and Return Valves Standard Sheet for DE LUXE Edition 1000 (0999) This series consists of HERZ radiator thermostats, HERZ-TS-90 thermostatic valves and HERZ return valves. These components
More informationJaspi GTV and Jaspi Oval. Jaspi Oval thermal storage tanks
Jaspi GTV and Jaspi Oval thermal storage tanks Jaspi GTV thermal storage tanks Classy and efficient, the GTV tanks are suitable for new applications as well as heating system renovations for expanding
More informationAUTOMATIC FILTERS. AG series HECTRON
AUTOMATIC FILTERS AG series HECTRON Automatic self-cleaning filters - AG series Equipped with a high-precision woven fabric filter screen, these automatic self-cleaning filters produce optimum quality
More informationCondensate Drain Valves
Innovative Compressed Air Products A Complete Line Of Drain Valves To Fit Every Compressed Air Condensate Removal Application WDV Series Condensate Drain Valves Leading Edge Technology CORPORATION Dimensions
More informationCalMag Filter Installation Instructions
Calming troubled waters CalMag Filter Installation Instructions Please note: This filter is unique and does not have or need a messy top mounted air bleed valve. Air is channelled via a snorkel arrangement
More informationBalancing & Control. Frese SIGMA Compact. Dynamic Balancing Valve
Balancing & Control Frese SIGMA Compact Dynamic Balancing Valve Balancing & Control Frese SIGMA Compact Frese Innovative solutions from Frese balance global HVAC systems accurately and efficiently. From
More informationThermoDual Domestic hot water charging system
ThermoDual Domestic hot water charging system Description/Application ThermoDual is the compact and effective domestic hot water (DHW) charging system. Due to the consistent use of carefully selected components
More informationTECHNICAL DATA. Wet 26a. February 22, 2009
February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve
More information