PRESTO. PrestoCHILL PrestoCHILL

Size: px
Start display at page:

Download "PRESTO. PrestoCHILL PrestoCHILL"

Transcription

1 Accessories for easierofoperation The unique protocol Excellent quality with the system The combination of freezing the specimens with and processing/staining the slides with the processor allows high-quality results in less than 0 minutes. Breast Thyroid 0X Eosin staining Lens paper disks for easy mounting Molds to fit every requirement Hematoxylin staining High throughput operations To eliminate the potential formation of ice on the freezing platform, an automatic defrost cycle is provided. It consists of an embedded heater in the freezing platform and a vacuum pump to extract water vapours vapors from the chamber. Vapours Vapors are arecondensed condensed and and collected in a cold-trap placed in the front of the unit for easy handling. A HEPA filter is provided on the exhaust side of the pump. Integrated software can set the defrost cycle to take place during off hours. Afterwards, the cooling cycle automatically restarts at a preset time to ensure the availability for the first case of the day, removing the need to manually monitor the system. -CATEN-00.indd -,- -CATEN-00_MD.indd freezing Processor/Stainer for high-quality frozensimultaneous sections The science of cryoembedding The science of cryoembedding for high-quality for high-quality frozen sections frozen sections No liquid nitrogen, no CO, no isopentane. Reduce processing/staining time tostep. minutes. No operations inside the cryostat chamber during the freezing HEPA cap filter. FLEXIBILITY ENVIRONMENTALLY FRIENDLY Set and modify protocols according to your specific requirements The technologically advanced Stirling cooler uses Helium gas as a refrigerant in a sealed stainless your ownisstaining reagents. steel chamber. No standarduse compressor used, therefore no CFCs (Chlorofluorocarbons). Xylene FULLY DOCUMENTABLE FULL DOCUMENTATION A USB port enables both software update and event log downloads. Enable both updating of sotware and downloading of event logs SPACE SAVING through USB port. Its reduced dimensions occupy minimum space in restricted lab environments. A wide variety of molds with different diameter and depth are available to fullfill every freezing requirement. Since the Immersion of a rack withdiameter up to slides for 0 the seconds Lens paper disks are an excellent support outside is always same they can in preheated ( C) FineFix solution for simultaneous: for freezing small fragments or delicate be rapidly exchanged to fit every situation. specimens making the difficult task specimen simple fixation, dehydration and clearing. FineFixofis a patented (EP B-US 0000) and rapid. Available in sizes (diameters formalin-free solution, ethanol based (0%) ideal for,, 0 mm). Built-in exhaust system. - Stirling cooler freezing module - Anodised aluminium freezing platform - Dimensions: height cm (with cover open cm) - width 0cm - depth cm - Weight: kg - Processor/Stainer for up to slides - Power supply: 0V~ 0 histological applications and molecular studies. Each mold can be separately timed through the built-in control panel. Up to samples can be frozen in parallel or in sequential order in less than minutes. / operations with fully automatic defrost feature Only 0 minutes from room to the operating temperature of -0 C. PRODUCTIVITY At the set temperature, biospecimens frozen simultaneously only 0 seconds. stained, Improve flowcan andbeproductivity. While slidesinare automatically Reduced trimming time at the cryostat state through specimen planarity in the cryoembedding compound. the operator is free to cryoembed and cut new specimens. Easy Operating operation Procedures make everyone an expert Best - Dimensions: h 80 cm/. (with cover open 8, cm/. ) **The Art of Embedding Tissue for Frozen Section. Part I: A System Precision Face Down Cryoembedding of Tissues Using Freezing w 0 cm/. - d for 9cm/. Temperature-Embedding Wells. Stephen R. Peters - The Journal of Histology / Vol., No. / March 00 - Weight: 0Kg - lbs **Paper Cryoembedding Stephen R. Peters - The Journal of Histology / Vol., No. / September 00 - Power supply: 0V~ 0/0Hz or V~ 0Hz (00W) A manual with Best Operating Procedures (BOP) is available with every unit. The QR code in this page is directly connected to video tutorials to make operations even easier.. How to identify frozen specimens. How to freeze breast and fatty tissues. How to simultaneously freeze small specimens. How to freeze long-thin specimens. How to freeze muscle tissues. How to freeze thin specimens on edge. How to freeze multiple thin specimens on edge 8. How to freeze skin for MOHS surgery Operator can easily set protocols to fit 9. How to freeze body fluids his lab requirements. -CAT0EN-00.indd - User friendly intuitive software. Intended for professionals only Lung FLEXIBLE IMPROVED MORPHOLOGY Standardized for all types of tissues, even for the most difficult to cut at the Standardised freezing at -0 C cryostat (such as breast, lymph nodes). Assure high quality, consistent staining results independent from Rapidly change out molds with a range of different sizes and designs. operator skill. MCC an optimised optimized cryoembedding compound Aceticformulation acid rinsing of MCC is a proprietary glycols and resins specifically developed for optimal support during cryotomy of dissected tissues down to -0 C. Being water soluble, MCC doesn t leave residue on the slides, eliminating nonwater specific Source rinsing background staining. Additionally, MCC will not dull microtome knives. The s MILESTONE Srl - Via Fatebenefratelli, / - 00 Sorisole (BG) - Italy Tel: Fax: medical@milestonesrl.com MILESTONE MEDICAL TECHNOLOGIES, INC. Technology Avenue, Suite F, Kalamazoo, MI USA Tel: Toll-free: Fax: info@milestonemed.com Wharfedale Road, Winnersh, Wokingham, Berkshire RG RA Tel: , Fax: enquiries@menarinidiag.co.uk MILESTONE Simultaneous freezing H E L P I N G P A T I E N T S CP80 CATEN-00 /0/ 09:09 0: /0/8 0:0 /0/

2 Need good results? Start with a good preparation The optimal frozen section begins with an evenly and completely frozen tissue block in which the block face that will be sectioned is flat and includes a complete, full faced section of the tissue submitted. The section should be free of ice crystal artifacts, knife lines, and/or tears. The speed and simplicity of s operations revolutionise the rapid freezing process, keeping the microscopic appearance of tissues true-to-life.. The first step towards high-quality frozen sections Simple. Intuitive operations Cryoembedding of delicate tissues - small fragments/mohs surgery During the practice of frozen section pathology, pathologists often encounter the task of embedding tissues that are extremely delicate because of the nature of their consistence and structure. This is a situation that occurs daily during Mohs surgery, in which the technologist handles delicate slivers of skin with the goal of accurately embedding these tissues to completely visualise the epidermis and its margin. The paper embedding technique offers a safe and rapid solution to these problems. ** Place a drop of the cryo-embedding compound on the tip of the spatula. Orient the specimen. Transfer the specimen to the bottom of the mold. The science of paper cryoembedding removable aluminum molds with a diameter of -0 mm. (Other sizes and shapes are available) Heat extractors Chuck freezing area - Benchtop cryoembedding station Time to redefine frozen sections Touch screen terminal (. ) Reduce freezing time to 0 seconds. Eliminate freezing artifacts through ultrafast freezing, preventing the formation of ice crystals. Cut fatty tissues like breast or lymph nodes without any sort of difficulty and without the distortion of delicate honeycomb structures. USB port for full documentation Cool trap for the defrost step Add the cryo-embedding compound to fill the mold. Place the chuck into the mold. Add the extractor and close the cover. Wet both sides of a small section of lens paper with the cryo-embedding compound. Position the specimen on the lens paper. Check its orientation. Gently slide the specimen, paper side down, into the mold. Add the cryo-embedding compound, the chuck and the heat extractor. After 0 seconds, the specimen is ready for section cutting. The lens paper is eliminated during the initial trimming of the block. The final result. Obtain perfectly flat plane surfaces to reduce trimming time and to cut easily while using the patented* face down embedding technique. Eliminate the compression of artifacts caused by extremely ultra low temperatures. Eliminate the retraction of tissues; for example, Glomeruli from Bowman s capsule, and vacuolation spaces around nucleated brain cells, related to formalin fixed, paraffin-embedded (FFPE) sections. This is how cryoembedding should be Freezing time 0 -CATEN-00.indd CATEN-00_MD.indd NO FREEZING ARTIFACTS 0 SECOND FREEZING TIME AN ALL-DRY SYSTEM FULL DOWNLOADABLE DOCUMENTATION NO LIQUID NITROGEN NO CO - NO ISOPENTANE 8 Start the timer. After 0 seconds A frozen block with a perfectly flat plane surface is ready for cutting. What sets us apart? Cryoembedding on edge THE UNIQUE COMBINATION OF THE PATENTED* FACE-DOWN EMBEDDING TECHNIQUE, TOGETHER WITH A STATE-OF-THE-ART, RAPID STIRLING COOLING DEVICE AT -0 C. With the help of a strip of cellulose it is possible to freeze the specimen on edge with the standard freezing procedure as paper disk cryoembedding. US PATENT,,9 B * /0/ 0:0 0: /0/8

3 Need good results? Start with a good preparation The optimal frozen section begins with an evenly and completely frozen tissue block in which the block face that will be sectioned is flat and includes a complete, full faced section of the tissue submitted. The section should be free of ice crystal artifacts, knife lines, and/or tears. The speed and simplicity of s operations revolutionise the rapid freezing process, keeping the microscopic appearance of tissues true-to-life.. The first step towards high-quality frozen sections Simple. Intuitive operations Cryoembedding of delicate tissues - small fragments/mohs surgery During the practice of frozen section pathology, pathologists often encounter the task of embedding tissues that are extremely delicate because of the nature of their consistence and structure. This is a situation that occurs daily during Mohs surgery, in which the technologist handles delicate slivers of skin with the goal of accurately embedding these tissues to completely visualise the epidermis and its margin. The paper embedding technique offers a safe and rapid solution to these problems. ** Place a drop of the cryo-embedding compound on the tip of the spatula. Orient the specimen. Transfer the specimen to the bottom of the mold. The science of paper cryoembedding removable aluminum molds with a diameter of -0 mm. (Other sizes and shapes are available) Heat extractors Chuck freezing area - Benchtop cryoembedding station Time to redefine frozen sections Touch screen terminal (. ) Reduce freezing time to 0 seconds. Eliminate freezing artifacts through ultrafast freezing, preventing the formation of ice crystals. Cut fatty tissues like breast or lymph nodes without any sort of difficulty and without the distortion of delicate honeycomb structures. USB port for full documentation Cool trap for the defrost step Add the cryo-embedding compound to fill the mold. Place the chuck into the mold. Add the extractor and close the cover. Wet both sides of a small section of lens paper with the cryo-embedding compound. Position the specimen on the lens paper. Check its orientation. Gently slide the specimen, paper side down, into the mold. Add the cryo-embedding compound, the chuck and the heat extractor. After 0 seconds, the specimen is ready for section cutting. The lens paper is eliminated during the initial trimming of the block. The final result. Obtain perfectly flat plane surfaces to reduce trimming time and to cut easily while using the patented* face down embedding technique. Eliminate the compression of artifacts caused by extremely ultra low temperatures. Eliminate the retraction of tissues; for example, Glomeruli from Bowman s capsule, and vacuolation spaces around nucleated brain cells, related to formalin fixed, paraffin-embedded (FFPE) sections. This is how cryoembedding should be Freezing time 0 -CATEN-00.indd CATEN-00_MD.indd NO FREEZING ARTIFACTS 0 SECOND FREEZING TIME AN ALL-DRY SYSTEM FULL DOWNLOADABLE DOCUMENTATION NO LIQUID NITROGEN NO CO - NO ISOPENTANE 8 Start the timer. After 0 seconds A frozen block with a perfectly flat plane surface is ready for cutting. What sets us apart? Cryoembedding on edge THE UNIQUE COMBINATION OF THE PATENTED* FACE-DOWN EMBEDDING TECHNIQUE, TOGETHER WITH A STATE-OF-THE-ART, RAPID STIRLING COOLING DEVICE AT -0 C. With the help of a strip of cellulose it is possible to freeze the specimen on edge with the standard freezing procedure as paper disk cryoembedding. US PATENT,,9 B * /0/ 0:0 0: /0/8

4 Need good results? Start with a good preparation The optimal frozen section begins with an evenly and completely frozen tissue block in which the block face that will be sectioned is flat and includes a complete, full faced section of the tissue submitted. The section should be free of ice crystal artifacts, knife lines, and/or tears. The speed and simplicity of s operations revolutionise the rapid freezing process, keeping the microscopic appearance of tissues true-to-life.. The first step towards high-quality frozen sections Simple. Intuitive operations Cryoembedding of delicate tissues - small fragments/mohs surgery During the practice of frozen section pathology, pathologists often encounter the task of embedding tissues that are extremely delicate because of the nature of their consistence and structure. This is a situation that occurs daily during Mohs surgery, in which the technologist handles delicate slivers of skin with the goal of accurately embedding these tissues to completely visualise the epidermis and its margin. The paper embedding technique offers a safe and rapid solution to these problems. ** Place a drop of the cryo-embedding compound on the tip of the spatula. Orient the specimen. Transfer the specimen to the bottom of the mold. The science of paper cryoembedding removable aluminum molds with a diameter of -0 mm. (Other sizes and shapes are available) Heat extractors Chuck freezing area - Benchtop cryoembedding station Time to redefine frozen sections Touch screen terminal (. ) Reduce freezing time to 0 seconds. Eliminate freezing artifacts through ultrafast freezing, preventing the formation of ice crystals. Cut fatty tissues like breast or lymph nodes without any sort of difficulty and without the distortion of delicate honeycomb structures. USB port for full documentation Cool trap for the defrost step Add the cryo-embedding compound to fill the mold. Place the chuck into the mold. Add the extractor and close the cover. Wet both sides of a small section of lens paper with the cryo-embedding compound. Position the specimen on the lens paper. Check its orientation. Gently slide the specimen, paper side down, into the mold. Add the cryo-embedding compound, the chuck and the heat extractor. After 0 seconds, the specimen is ready for section cutting. The lens paper is eliminated during the initial trimming of the block. The final result. Obtain perfectly flat plane surfaces to reduce trimming time and to cut easily while using the patented* face down embedding technique. Eliminate the compression of artifacts caused by extremely ultra low temperatures. Eliminate the retraction of tissues; for example, Glomeruli from Bowman s capsule, and vacuolation spaces around nucleated brain cells, related to formalin fixed, paraffin-embedded (FFPE) sections. This is how cryoembedding should be Freezing time 0 -CATEN-00.indd CATEN-00_MD.indd NO FREEZING ARTIFACTS 0 SECOND FREEZING TIME AN ALL-DRY SYSTEM FULL DOWNLOADABLE DOCUMENTATION NO LIQUID NITROGEN NO CO - NO ISOPENTANE 8 Start the timer. After 0 seconds A frozen block with a perfectly flat plane surface is ready for cutting. What sets us apart? Cryoembedding on edge THE UNIQUE COMBINATION OF THE PATENTED* FACE-DOWN EMBEDDING TECHNIQUE, TOGETHER WITH A STATE-OF-THE-ART, RAPID STIRLING COOLING DEVICE AT -0 C. With the help of a strip of cellulose it is possible to freeze the specimen on edge with the standard freezing procedure as paper disk cryoembedding. US PATENT,,9 B * /0/ 0:0 0: /0/8

5 Need good results? Start with a good preparation The optimal frozen section begins with an evenly and completely frozen tissue block in which the block face that will be sectioned is flat and includes a complete, full faced section of the tissue submitted. The section should be free of ice crystal artifacts, knife lines, and/or tears. The speed and simplicity of s operations revolutionise the rapid freezing process, keeping the microscopic appearance of tissues true-to-life.. The first step towards high-quality frozen sections Simple. Intuitive operations Cryoembedding of delicate tissues - small fragments/mohs surgery During the practice of frozen section pathology, pathologists often encounter the task of embedding tissues that are extremely delicate because of the nature of their consistence and structure. This is a situation that occurs daily during Mohs surgery, in which the technologist handles delicate slivers of skin with the goal of accurately embedding these tissues to completely visualise the epidermis and its margin. The paper embedding technique offers a safe and rapid solution to these problems. ** Place a drop of the cryo-embedding compound on the tip of the spatula. Orient the specimen. Transfer the specimen to the bottom of the mold. The science of paper cryoembedding removable aluminum molds with a diameter of -0 mm. (Other sizes and shapes are available) Heat extractors Chuck freezing area - Benchtop cryoembedding station Time to redefine frozen sections Touch screen terminal (. ) Reduce freezing time to 0 seconds. Eliminate freezing artifacts through ultrafast freezing, preventing the formation of ice crystals. Cut fatty tissues like breast or lymph nodes without any sort of difficulty and without the distortion of delicate honeycomb structures. USB port for full documentation Cool trap for the defrost step Add the cryo-embedding compound to fill the mold. Place the chuck into the mold. Add the extractor and close the cover. Wet both sides of a small section of lens paper with the cryo-embedding compound. Position the specimen on the lens paper. Check its orientation. Gently slide the specimen, paper side down, into the mold. Add the cryo-embedding compound, the chuck and the heat extractor. After 0 seconds, the specimen is ready for section cutting. The lens paper is eliminated during the initial trimming of the block. The final result. Obtain perfectly flat plane surfaces to reduce trimming time and to cut easily while using the patented* face down embedding technique. Eliminate the compression of artifacts caused by extremely ultra low temperatures. Eliminate the retraction of tissues; for example, Glomeruli from Bowman s capsule, and vacuolation spaces around nucleated brain cells, related to formalin fixed, paraffin-embedded (FFPE) sections. This is how cryoembedding should be Freezing time 0 -CATEN-00.indd CATEN-00_MD.indd NO FREEZING ARTIFACTS 0 SECOND FREEZING TIME AN ALL-DRY SYSTEM FULL DOWNLOADABLE DOCUMENTATION NO LIQUID NITROGEN NO CO - NO ISOPENTANE 8 Start the timer. After 0 seconds A frozen block with a perfectly flat plane surface is ready for cutting. What sets us apart? Cryoembedding on edge THE UNIQUE COMBINATION OF THE PATENTED* FACE-DOWN EMBEDDING TECHNIQUE, TOGETHER WITH A STATE-OF-THE-ART, RAPID STIRLING COOLING DEVICE AT -0 C. With the help of a strip of cellulose it is possible to freeze the specimen on edge with the standard freezing procedure as paper disk cryoembedding. US PATENT,,9 B * /0/ 0:0 0: /0/8

6 Accessories for easierofoperation The unique protocol Excellent quality with the system The combination of freezing the specimens with and processing/staining the slides with the processor allows high-quality results in less than 0 minutes. Breast Thyroid 0X Eosin staining Lens paper disks for easy mounting Molds to fit every requirement Hematoxylin staining High throughput operations To eliminate the potential formation of ice on the freezing platform, an automatic defrost cycle is provided. It consists of an embedded heater in the freezing platform and a vacuum pump to extract water vapours vapors from the chamber. Vapours Vapors are arecondensed condensed and and collected in a cold-trap placed in the front of the unit for easy handling. A HEPA filter is provided on the exhaust side of the pump. Integrated software can set the defrost cycle to take place during off hours. Afterwards, the cooling cycle automatically restarts at a preset time to ensure the availability for the first case of the day, removing the need to manually monitor the system. -CATEN-00.indd -,- -CATEN-00_MD.indd freezing Processor/Stainer for high-quality frozensimultaneous sections The science of cryoembedding The science of cryoembedding for high-quality for high-quality frozen sections frozen sections No liquid nitrogen, no CO, no isopentane. Reduce processing/staining time tostep. minutes. No operations inside the cryostat chamber during the freezing HEPA cap filter. FLEXIBILITY ENVIRONMENTALLY FRIENDLY Set and modify protocols according to your specific requirements The technologically advanced Stirling cooler uses Helium gas as a refrigerant in a sealed stainless your ownisstaining reagents. steel chamber. No standarduse compressor used, therefore no CFCs (Chlorofluorocarbons). Xylene FULLY DOCUMENTABLE FULL DOCUMENTATION A USB port enables both software update and event log downloads. Enable both updating of sotware and downloading of event logs SPACE SAVING through USB port. Its reduced dimensions occupy minimum space in restricted lab environments. A wide variety of molds with different diameter and depth are available to fullfill every freezing requirement. Since the Immersion of a rack withdiameter up to slides for 0 the seconds Lens paper disks are an excellent support outside is always same they can in preheated ( C) FineFix solution for simultaneous: for freezing small fragments or delicate be rapidly exchanged to fit every situation. specimens making the difficult task specimen simple fixation, dehydration and clearing. FineFixofis a patented (EP B-US 0000) and rapid. Available in sizes (diameters formalin-free solution, ethanol based (0%) ideal for,, 0 mm). Built-in exhaust system. - Stirling cooler freezing module - Anodised aluminium freezing platform - Dimensions: height cm (with cover open cm) - width 0cm - depth cm - Weight: kg - Processor/Stainer for up to slides - Power supply: 0V~ 0 histological applications and molecular studies. Each mold can be separately timed through the built-in control panel. Up to samples can be frozen in parallel or in sequential order in less than minutes. / operations with fully automatic defrost feature Only 0 minutes from room to the operating temperature of -0 C. PRODUCTIVITY At the set temperature, biospecimens frozen simultaneously only 0 seconds. stained, Improve flowcan andbeproductivity. While slidesinare automatically Reduced trimming time at the cryostat state through specimen planarity in the cryoembedding compound. the operator is free to cryoembed and cut new specimens. Easy Operating operation Procedures make everyone an expert Best - Dimensions: h 80 cm/. (with cover open 8, cm/. ) **The Art of Embedding Tissue for Frozen Section. Part I: A System Precision Face Down Cryoembedding of Tissues Using Freezing w 0 cm/. - d for 9cm/. Temperature-Embedding Wells. Stephen R. Peters - The Journal of Histology / Vol., No. / March 00 - Weight: 0Kg - lbs **Paper Cryoembedding Stephen R. Peters - The Journal of Histology / Vol., No. / September 00 - Power supply: 0V~ 0/0Hz or V~ 0Hz (00W) A manual with Best Operating Procedures (BOP) is available with every unit. The QR code in this page is directly connected to video tutorials to make operations even easier.. How to identify frozen specimens. How to freeze breast and fatty tissues. How to simultaneously freeze small specimens. How to freeze long-thin specimens. How to freeze muscle tissues. How to freeze thin specimens on edge. How to freeze multiple thin specimens on edge 8. How to freeze skin for MOHS surgery Operator can easily set protocols to fit 9. How to freeze body fluids his lab requirements. -CAT0EN-00.indd - User friendly intuitive software. Intended for professionals only Lung FLEXIBLE IMPROVED MORPHOLOGY Standardized for all types of tissues, even for the most difficult to cut at the Standardised freezing at -0 C cryostat (such as breast, lymph nodes). Assure high quality, consistent staining results independent from Rapidly change out molds with a range of different sizes and designs. operator skill. MCC an optimised optimized cryoembedding compound Aceticformulation acid rinsing of MCC is a proprietary glycols and resins specifically developed for optimal support during cryotomy of dissected tissues down to -0 C. Being water soluble, MCC doesn t leave residue on the slides, eliminating nonwater specific Source rinsing background staining. Additionally, MCC will not dull microtome knives. The s MILESTONE Srl - Via Fatebenefratelli, / - 00 Sorisole (BG) - Italy Tel: Fax: medical@milestonesrl.com MILESTONE MEDICAL TECHNOLOGIES, INC. Technology Avenue, Suite F, Kalamazoo, MI USA Tel: Toll-free: Fax: info@milestonemed.com Wharfedale Road, Winnersh, Wokingham, Berkshire RG RA Tel: , Fax: enquiries@menarinidiag.co.uk MILESTONE Simultaneous freezing H E L P I N G P A T I E N T S CP80 CATEN-00 /0/ 09:09 0: /0/8 0:0 /0/

7 Accessories for easierofoperation The unique protocol Excellent quality with the system The combination of freezing the specimens with and processing/staining the slides with the processor allows high-quality results in less than 0 minutes. Breast Thyroid 0X Eosin staining Lens paper disks for easy mounting Molds to fit every requirement Hematoxylin staining High throughput operations To eliminate the potential formation of ice on the freezing platform, an automatic defrost cycle is provided. It consists of an embedded heater in the freezing platform and a vacuum pump to extract water vapours vapors from the chamber. Vapours Vapors are arecondensed condensed and and collected in a cold-trap placed in the front of the unit for easy handling. A HEPA filter is provided on the exhaust side of the pump. Integrated software can set the defrost cycle to take place during off hours. Afterwards, the cooling cycle automatically restarts at a preset time to ensure the availability for the first case of the day, removing the need to manually monitor the system. -CATEN-00.indd -,- -CATEN-00_MD.indd freezing Processor/Stainer for high-quality frozensimultaneous sections The science of cryoembedding The science of cryoembedding for high-quality for high-quality frozen sections frozen sections No liquid nitrogen, no CO, no isopentane. Reduce processing/staining time tostep. minutes. No operations inside the cryostat chamber during the freezing HEPA cap filter. FLEXIBILITY ENVIRONMENTALLY FRIENDLY Set and modify protocols according to your specific requirements The technologically advanced Stirling cooler uses Helium gas as a refrigerant in a sealed stainless your ownisstaining reagents. steel chamber. No standarduse compressor used, therefore no CFCs (Chlorofluorocarbons). Xylene FULLY DOCUMENTABLE FULL DOCUMENTATION A USB port enables both software update and event log downloads. Enable both updating of sotware and downloading of event logs SPACE SAVING through USB port. Its reduced dimensions occupy minimum space in restricted lab environments. A wide variety of molds with different diameter and depth are available to fullfill every freezing requirement. Since the Immersion of a rack withdiameter up to slides for 0 the seconds Lens paper disks are an excellent support outside is always same they can in preheated ( C) FineFix solution for simultaneous: for freezing small fragments or delicate be rapidly exchanged to fit every situation. specimens making the difficult task specimen simple fixation, dehydration and clearing. FineFixofis a patented (EP B-US 0000) and rapid. Available in sizes (diameters formalin-free solution, ethanol based (0%) ideal for,, 0 mm). Built-in exhaust system. - Stirling cooler freezing module - Anodised aluminium freezing platform - Dimensions: height cm (with cover open cm) - width 0cm - depth cm - Weight: kg - Processor/Stainer for up to slides - Power supply: 0V~ 0 histological applications and molecular studies. Each mold can be separately timed through the built-in control panel. Up to samples can be frozen in parallel or in sequential order in less than minutes. / operations with fully automatic defrost feature Only 0 minutes from room to the operating temperature of -0 C. PRODUCTIVITY At the set temperature, biospecimens frozen simultaneously only 0 seconds. stained, Improve flowcan andbeproductivity. While slidesinare automatically Reduced trimming time at the cryostat state through specimen planarity in the cryoembedding compound. the operator is free to cryoembed and cut new specimens. Easy Operating operation Procedures make everyone an expert Best - Dimensions: h 80 cm/. (with cover open 8, cm/. ) **The Art of Embedding Tissue for Frozen Section. Part I: A System Precision Face Down Cryoembedding of Tissues Using Freezing w 0 cm/. - d for 9cm/. Temperature-Embedding Wells. Stephen R. Peters - The Journal of Histology / Vol., No. / March 00 - Weight: 0Kg - lbs **Paper Cryoembedding Stephen R. Peters - The Journal of Histology / Vol., No. / September 00 - Power supply: 0V~ 0/0Hz or V~ 0Hz (00W) A manual with Best Operating Procedures (BOP) is available with every unit. The QR code in this page is directly connected to video tutorials to make operations even easier.. How to identify frozen specimens. How to freeze breast and fatty tissues. How to simultaneously freeze small specimens. How to freeze long-thin specimens. How to freeze muscle tissues. How to freeze thin specimens on edge. How to freeze multiple thin specimens on edge 8. How to freeze skin for MOHS surgery Operator can easily set protocols to fit 9. How to freeze body fluids his lab requirements. -CAT0EN-00.indd - User friendly intuitive software. Intended for professionals only Lung FLEXIBLE IMPROVED MORPHOLOGY Standardized for all types of tissues, even for the most difficult to cut at the Standardised freezing at -0 C cryostat (such as breast, lymph nodes). Assure high quality, consistent staining results independent from Rapidly change out molds with a range of different sizes and designs. operator skill. MCC an optimised optimized cryoembedding compound Aceticformulation acid rinsing of MCC is a proprietary glycols and resins specifically developed for optimal support during cryotomy of dissected tissues down to -0 C. Being water soluble, MCC doesn t leave residue on the slides, eliminating nonwater specific Source rinsing background staining. Additionally, MCC will not dull microtome knives. The s MILESTONE Srl - Via Fatebenefratelli, / - 00 Sorisole (BG) - Italy Tel: Fax: medical@milestonesrl.com MILESTONE MEDICAL TECHNOLOGIES, INC. Technology Avenue, Suite F, Kalamazoo, MI USA Tel: Toll-free: Fax: info@milestonemed.com Wharfedale Road, Winnersh, Wokingham, Berkshire RG RA Tel: , Fax: enquiries@menarinidiag.co.uk MILESTONE Simultaneous freezing H E L P I N G P A T I E N T S CP80 CATEN-00 /0/ 09:09 0: /0/8 0:0 /0/

8 Accessories for easierofoperation The unique protocol Excellent quality with the system The combination of freezing the specimens with and processing/staining the slides with the processor allows high-quality results in less than 0 minutes. Breast Thyroid 0X Eosin staining Lens paper disks for easy mounting Molds to fit every requirement Hematoxylin staining High throughput operations To eliminate the potential formation of ice on the freezing platform, an automatic defrost cycle is provided. It consists of an embedded heater in the freezing platform and a vacuum pump to extract water vapours vapors from the chamber. Vapours Vapors are arecondensed condensed and and collected in a cold-trap placed in the front of the unit for easy handling. A HEPA filter is provided on the exhaust side of the pump. Integrated software can set the defrost cycle to take place during off hours. Afterwards, the cooling cycle automatically restarts at a preset time to ensure the availability for the first case of the day, removing the need to manually monitor the system. -CATEN-00.indd -,- -CATEN-00_MD.indd freezing Processor/Stainer for high-quality frozensimultaneous sections The science of cryoembedding The science of cryoembedding for high-quality for high-quality frozen sections frozen sections No liquid nitrogen, no CO, no isopentane. Reduce processing/staining time tostep. minutes. No operations inside the cryostat chamber during the freezing HEPA cap filter. FLEXIBILITY ENVIRONMENTALLY FRIENDLY Set and modify protocols according to your specific requirements The technologically advanced Stirling cooler uses Helium gas as a refrigerant in a sealed stainless your ownisstaining reagents. steel chamber. No standarduse compressor used, therefore no CFCs (Chlorofluorocarbons). Xylene FULLY DOCUMENTABLE FULL DOCUMENTATION A USB port enables both software update and event log downloads. Enable both updating of sotware and downloading of event logs SPACE SAVING through USB port. Its reduced dimensions occupy minimum space in restricted lab environments. A wide variety of molds with different diameter and depth are available to fullfill every freezing requirement. Since the Immersion of a rack withdiameter up to slides for 0 the seconds Lens paper disks are an excellent support outside is always same they can in preheated ( C) FineFix solution for simultaneous: for freezing small fragments or delicate be rapidly exchanged to fit every situation. specimens making the difficult task specimen simple fixation, dehydration and clearing. FineFixofis a patented (EP B-US 0000) and rapid. Available in sizes (diameters formalin-free solution, ethanol based (0%) ideal for,, 0 mm). Built-in exhaust system. - Stirling cooler freezing module - Anodised aluminium freezing platform - Dimensions: height cm (with cover open cm) - width 0cm - depth cm - Weight: kg - Processor/Stainer for up to slides - Power supply: 0V~ 0 histological applications and molecular studies. Each mold can be separately timed through the built-in control panel. Up to samples can be frozen in parallel or in sequential order in less than minutes. / operations with fully automatic defrost feature Only 0 minutes from room to the operating temperature of -0 C. PRODUCTIVITY At the set temperature, biospecimens frozen simultaneously only 0 seconds. stained, Improve flowcan andbeproductivity. While slidesinare automatically Reduced trimming time at the cryostat state through specimen planarity in the cryoembedding compound. the operator is free to cryoembed and cut new specimens. Easy Operating operation Procedures make everyone an expert Best - Dimensions: h 80 cm/. (with cover open 8, cm/. ) **The Art of Embedding Tissue for Frozen Section. Part I: A System Precision Face Down Cryoembedding of Tissues Using Freezing w 0 cm/. - d for 9cm/. Temperature-Embedding Wells. Stephen R. Peters - The Journal of Histology / Vol., No. / March 00 - Weight: 0Kg - lbs **Paper Cryoembedding Stephen R. Peters - The Journal of Histology / Vol., No. / September 00 - Power supply: 0V~ 0/0Hz or V~ 0Hz (00W) A manual with Best Operating Procedures (BOP) is available with every unit. The QR code in this page is directly connected to video tutorials to make operations even easier.. How to identify frozen specimens. How to freeze breast and fatty tissues. How to simultaneously freeze small specimens. How to freeze long-thin specimens. How to freeze muscle tissues. How to freeze thin specimens on edge. How to freeze multiple thin specimens on edge 8. How to freeze skin for MOHS surgery Operator can easily set protocols to fit 9. How to freeze body fluids his lab requirements. -CAT0EN-00.indd - User friendly intuitive software. Intended for professionals only Lung FLEXIBLE IMPROVED MORPHOLOGY Standardized for all types of tissues, even for the most difficult to cut at the Standardised freezing at -0 C cryostat (such as breast, lymph nodes). Assure high quality, consistent staining results independent from Rapidly change out molds with a range of different sizes and designs. operator skill. MCC an optimised optimized cryoembedding compound Aceticformulation acid rinsing of MCC is a proprietary glycols and resins specifically developed for optimal support during cryotomy of dissected tissues down to -0 C. Being water soluble, MCC doesn t leave residue on the slides, eliminating nonwater specific Source rinsing background staining. Additionally, MCC will not dull microtome knives. The s MILESTONE Srl - Via Fatebenefratelli, / - 00 Sorisole (BG) - Italy Tel: Fax: medical@milestonesrl.com MILESTONE MEDICAL TECHNOLOGIES, INC. Technology Avenue, Suite F, Kalamazoo, MI USA Tel: Toll-free: Fax: info@milestonemed.com Wharfedale Road, Winnersh, Wokingham, Berkshire RG RA Tel: , Fax: enquiries@menarinidiag.co.uk MILESTONE Simultaneous freezing H E L P I N G P A T I E N T S CP80 CATEN-00 /0/ 09:09 0: /0/8 0:0 /0/

Thermo Scientific Cryostat Series

Thermo Scientific Cryostat Series Thermo Scientific Cryostat Series Clinical/Research/Industrial World-Class Sections Unmatched Ergonomics Leading-Edge Safety Unique Solutions for Unique Demands in Clinical and Research Laboratories The

More information

PrestoCHILL Flash Chiller for Frozen Sections. Operator Manual - MM138

PrestoCHILL Flash Chiller for Frozen Sections. Operator Manual - MM138 Flash Chiller for Frozen Sections Operator Manual - MM138 Thank you for having selected our system and welcome to the ever growing world club of users for Milestone laboratory instrumentation. We are

More information

Overview. rotary microtomes

Overview. rotary microtomes rotary microtomes Overview All SLEE microtomes are produced at the company s seat in Mainz, Germany. The highly precise, modularly built rotary microtomes range from a manual unit, type CUT 4062, via the

More information

Thermo Scientific Microm HM550 cryostat

Thermo Scientific Microm HM550 cryostat With gold standard disinfection in 3 minutes Thermo Scientific Microm HM550 cryostat Safety Part of Thermo Fisher Scientific Ergonomics Quality Precision Avoid the risk of occupational infections with

More information

PELCO HistoWave Laboratory Tissue Processing System

PELCO HistoWave Laboratory Tissue Processing System Stat Histology Processing with Quality Results PELCO HistoWave Laboratory Tissue Processing System The PELCO HistoWave is a tissue processing system that allows the histology lab to deliver results, from

More information

TISSUE EMBEDDING CENTER

TISSUE EMBEDDING CENTER TISSUE EMBEDDING CENTER Tissue Embedding Center (Model No. : MW-3080-STE-004) Tissue embedding system is designed fit your needs. Each high capacity module is designed with temperature controls that can

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Cryostat MNT INS2500GB 2011-08-09 Instructions MNT 1 Instructions MNT 2 CONTENTS 1. INTENDED USE... 4 2. SYMBOLS... 4 3. SAFETY NOTES... 4 4. COMPONENTS... 9 5. SPECIFICATIONS...

More information

Thermo Scientific Microm HM355S microtome

Thermo Scientific Microm HM355S microtome Safest sectioning even of largest specimen Thermo Scientific Microm HM355S microtome Precision Quality Ergonomics Safety Part of Thermo Fisher Scientific Thermo Scientific Microm HM355S optimised microtomy

More information

ETHOS UP HIGH PERFORMANCE MICROWAVE DIGESTION SYSTEM MILESTONE

ETHOS UP HIGH PERFORMANCE MICROWAVE DIGESTION SYSTEM MILESTONE ETHOS UP HIGH PERFORMANCE MICROWAVE DIGESTION SYSTEM MILESTONE H E L P I N G C H E M I S T S MILESTONE ETHOS UP It is a common misconception that a laboratory microwave is just a microwave and that there

More information

Why use Blast Chiller or Freezer?

Why use Blast Chiller or Freezer? Why use Blast Chiller or Freezer? Food safety is of utmost importance in all food industries. Time and temperature relationship are critical to the growth and spread of contamination. Bacteria multiplies

More information

Product catalog 2009/2010 clear cut design. dynamic tradition.

Product catalog 2009/2010 clear cut design. dynamic tradition. Product catalog 2009/2010 clear cut design. dynamic tradition. Tissue Processors Embedding Centers Microtomes Cryostats Floating Bath & Slide Warmer Staining Systems Cover Slipper Cytocentrifuge clear

More information

GENERAL PURPOSE LABORATORY GRADE REFRIGERATORS AND FREEZERS. Versatile 4 C and -20 C preservation for laboratory research and life science materials.

GENERAL PURPOSE LABORATORY GRADE REFRIGERATORS AND FREEZERS. Versatile 4 C and -20 C preservation for laboratory research and life science materials. GENERAL PURPOSE LABORATORY GRADE REFRIGERATORS AND FREEZERS General Purpose Lab Grade Refrigerators: General Purpose Lab Grade Freezers: GPR-22-1 (10829-224) GPR-50-2 (10829-226) GPR-72-3 (10829-228) GPF-24-1

More information

Quality Lab Products Instruments & Consumables

Quality Lab Products Instruments & Consumables Quality Lab Products Instruments & Consumables Made in Germany since 1978 www.medite-group.com MEDITE Inc. 1226 Winter Garden Vineland Road, Suite 104 Winter Garden, FL 34787, U.S.A. Phone: +1 (407) 996

More information

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow Thermo Scientific Rocket Evaporator Revolutionary solvent evaporation complete laboratory workflow Sample evaporation with walkaway capability to produce uncompromised results The Thermo Scientific Rocket

More information

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL Sakura Finetek Japan Co., Ltd., Tokyo 103-0023, Japan Sakura Finetek U.S.A., Inc., Torrance, CA 90501, USA Sakura Finetek Europe B.V., Zoeterwoude, Netherlands

More information

Zefiro Line. Ventilated workstation for anatomic pathology. The quality is in the air

Zefiro Line. Ventilated workstation for anatomic pathology. The quality is in the air Zefiro Line Ventilated workstation for anatomic pathology The quality is in the air Plus Autopsy Accessioning Grossing Interior design Index 6 Why Zefiro Line 12 Autopsy table 14 DIGIview Macro images

More information

Laboratory Freeze Dryers Routine Applications

Laboratory Freeze Dryers Routine Applications Laboratory Freeze Dryers Routine Applications Reliable and flexible New controller www.martinchrist.de 2 3 Process reliability & flexibility For all your applications Let our experience, skill, and flexibility

More information

ULTRA LOW TEMPERATURE FREEZER. User Manual

ULTRA LOW TEMPERATURE FREEZER. User Manual ULTRA LOW TEMPERATURE FREEZER User Manual Note:Kaltis reserves the right to modify any parts of this manual without prior notice. 1. No part of this manual may be reproduced in any form, or translated

More information

Compresstome VF-300-0Z User Manual

Compresstome VF-300-0Z User Manual Compresstome VF-300-0Z User Manual 1 Compresstome VF-300-0Z User Manual TABLE OF CONTENTS Table of contents... 2 Introduction... 3 Contact us... 3 Training videos... 2 Anatomy of the Compresstome VF-300-0Z...

More information

Zoom HT Microplate Washer. The Fastest Microplate Washer For The Life Sciences

Zoom HT Microplate Washer. The Fastest Microplate Washer For The Life Sciences Zoom HT Microplate Washer The Fastest Microplate Washer For The Life Sciences Advanced Tools for The Life Sciences www.titertek-berthold.com Zoom HT Microplate Washer Zoom HT is fast It takes only 17 seconds

More information

BLAST CHILLERS BENEFITS

BLAST CHILLERS BENEFITS BLAST CHILLERS BENEFITS INCREASE THE PRODUCT SAFETY The blast chilling and shock freezing processes allow to minimize the bacterial growth, that starts immediately after their cooking, and the macro-crystallization,

More information

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work Zoom Microplate Washer and Washer-Dispenser Reliable Solutions for Your Daily Work Zoom Microplate Washer and Washer-Dispenser Whether your workload is only a few or several hundreds of microplates per

More information

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS ARCTIKO AIMS to be the first and best choice of partner in delivering advanced and customized cooling and freezing solutions

More information

OTF5000 Cryostat. At the cutting edge of sectioning technology

OTF5000 Cryostat. At the cutting edge of sectioning technology OTF5000 Cryostat At the cutting edge of sectioning technology Bright Introduction Based on the long-established and reliable OTF/AS cryostat, the new OTF5000 brings Bright cryostats completely up to date.

More information

ROTARY EVAPORATORS EVAPORATION SOLUTIONS

ROTARY EVAPORATORS EVAPORATION SOLUTIONS ROTARY EVAPORATORS EVAPORATION SOLUTIONS WWW.LABTECHSRL.COM EVAPORATION SOLUTIONS The LabTech evaporation solutions introduce a new concept in routine distillation/evaporation processes: safety, efficiency

More information

PILOT-15 CENTRIFUGAL MOLECULAR DISTILLATION SYSTEM

PILOT-15 CENTRIFUGAL MOLECULAR DISTILLATION SYSTEM PILOT-15 CENTRIFUGAL MOLECULAR DISTILLATION SYSTEM MYERS VACUUM, Inc. DISTILLATION DIVISION 1155 MYERS LANE KITTANNING, PA 16201 TEL: (724) 545-8331 FAX: (724) 545-8332 www.myers-vacuum.com Rev. 03-16

More information

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation EN Customers. The core of our innovation Feeding&Conveying Drying Dosing Temperature Control Refrigeration Granulation Piovan Drying Technologies: Desiccant Bed Dryers Dried air is generated by means of

More information

No other product in this category delivers the same performance

No other product in this category delivers the same performance ICY No other product in this category delivers the same performance You ll immediately appreciate the Irinox technology because it has everything you need, at the lowest price ever. Irinox technology

More information

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories Freeze Dry Systems and Accessories FreeZone Freeze Dry Systems AN OVERVIEW Table of Contents: Overview...1 Selection Guide...4 FreeZone Freeze Dry Systems 1 Liter Benchtop...6 2.5 Liter Benchtop...8 2.5

More information

VWR Laboratory Refrigerators and Freezers

VWR Laboratory Refrigerators and Freezers VWR Laboratory Refrigerators and Freezers 01. VERSATILE STORAGE OPTIONS DESIGNED FOR YOUR NEEDS 02. SUPERIOR UNIFORMITY AND RECOVERY AFTER DOOR OPENINGS 03. OUTSTANDING TECHNICAL SERVICE Going green. What

More information

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories Freeze Dry Systems and Accessories Freeze Dry Systems AN OVERVIEW Table of Contents: Overview................................... 1 Selection Guide.............................. 4 FreeZone Freeze Dry Systems

More information

Digital incubating/ refrigerating benchtop shakers

Digital incubating/ refrigerating benchtop shakers I Incubators Incubated Shakers (Benchtop Models) Digital incubating/ refrigerating benchtop shakers Transparent lid offers great visibility and gas spring supports ensure hand-down handling of the samples

More information

Thermo Scientific HM525 NX Operator Guide Issue 2.0

Thermo Scientific HM525 NX Operator Guide Issue 2.0 Thermo Scientific HM525 NX Operator Guide 388159 Issue 2.0 Company Information 2 Thermo Scientific HM525 NX Company Information Company Information Copyright 2013. Thermo Fisher Scientific Inc. All rights

More information

Pilot Freeze Dryers Smart Processes

Pilot Freeze Dryers Smart Processes Pilot Freeze Dryers Smart Processes Powerful and highly efficient www.martinchrist.de 2 3 Best equipment for R&D and small production Pilot freeze dryers from Martin Christ are ideal for R&D or small production

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Paraffin Wax Embedding Centre MPS/P2 INS3100GB 03-2011-06 Instructions MPS/P2 1 Instructions MPS/P2 2 CONTENTS 1. INTENDED USE... 4 2. SYMBOLS... 4 3. SAFETY NOTES... 4 4. COMPONENTS...

More information

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32 Ultra Deep Freezers Biomedical Refrigeration I UF -86 C Technology for life 504170_8pages_dometic_UF.indd 1 10/09/08 11:17:32 UF - Ultra Deep Freezers up to -86 C The models UF 455 G & UF 755 G reflect

More information

TETHYS H10 PLUS. As a result of constant technological updating, the technical data may be subject to change without prior notice.

TETHYS H10 PLUS. As a result of constant technological updating, the technical data may be subject to change without prior notice. Stabilimento / Plant Via Bicocca, 14/c 40026 Imola - Bo (Italy) tel. +39 0542 653441 fax +39 0542 653601 Sede Legale ed Amministrativa Headquarters Cefla s.c. Via Selice Provinciale, 23/a 40026 Imola -

More information

Multi-Lab REFRIGERATORS Frigidere medicale

Multi-Lab REFRIGERATORS Frigidere medicale REFRIGERATORS REFRIGERATORS 2 finishings available, epoxy coated steel white colour or stainless steel (according to the model) high insulation thickness from 40 to 75 mm (according to the model) (1) rounded

More information

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter by Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Technical Specifications Brouwer -86 o C Chest STORAGE SPECS UNIT -86 DFC 370-86 DFC 620-86 DFC 820 Capacity L 370 620

More information

Development Centre for Evaporation and Thermal Separation Technologies

Development Centre for Evaporation and Thermal Separation Technologies Development Centre for Evaporation and Thermal Separation Technologies The Pilot Plant of GIG Karasek Our Company In Europe, GIG Karasek is a leading manufacturer in the field of system and apparatus construction

More information

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION SCANDINAVIAN DESIGN AND ULTIMATE PERFORMANCE TECHNOLOGY Arctiko

More information

PR / MP I Laboratory / Medicine

PR / MP I Laboratory / Medicine Technology for Life Medical SYSTEMS Technology for Life PR / MP I Laboratory / Medicine / Pharmaceutical Refrigerators (with glass door) +5 C +4 C 292.9707.80 02/2013 BIOMEDICAL REFRIGERATION Innovative

More information

Introduction to Pharmaceutical Freeze Drying

Introduction to Pharmaceutical Freeze Drying Introduction to Pharmaceutical Freeze Drying David Debo, PE Date 1 Agenda Introduction Stages of the process System components 2 Introduction What is lyophilization? What is sublimation? Why freeze dry?

More information

PLC Control Touch-Screen

PLC Control Touch-Screen Almost all laboratory freeze-drying processes can be carried out using this basic unit and the wide range of accessories available. The 4K incorporates a stainless steel cooled trap that can be easily

More information

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure Advancing the power of SPE Intelligent Automated Solid Phase Extraction SmartPrep Brochure SmartPrep Extractor: Simplify Cartridge-based Solid Phase Extraction Unprecedented versatility SmartPrep is the

More information

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Igloo Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Igloo More samples, less footprint Laboratory space is valuable. In comparison with the traditional freezers, Telstar

More information

Best Freeze Drying Solutions

Best Freeze Drying Solutions Best Freeze Drying Solutions The ultimate plus Pilot Freeze Dryers Epsilon 2-6D LSCplus Epsilon 2-10D LSCplus 2 Best Drying Results Advanced System Technology for Best Drying Results The freeze dryer EPSILON

More information

Tethys H10 The Evolution of Disinfection

Tethys H10 The Evolution of Disinfection Mocom S.r.l. reserves the right to modify the products illustrated in the photos without prior notice. 11/14 MH10GB141S00 Tethys H10 The Evolution of Disinfection easy, it s Mocom STERILIZATION FIRST STERILIZATION

More information

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories Freeze Dry Systems and Accessories FreeZone Freeze Dry Systems a n o v e r v i e w Table of Contents: Overview................................... 1 Selection Guide.............................. 4 FreeZone

More information

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer Platinous temperature and humidity chambers Top Quality Design With an Easy-to-use Touch-Screen Programmer Platinous chambers are innovative, built with the busy user in mind. If you have ever used an

More information

SIMPLICITY IS INNOVATION

SIMPLICITY IS INNOVATION SIMPLICITY IS INNOVATION MAKING A DIFFERENCE IN KITCHENS WORLDWIDE Your kitchen is constantly balancing the need for efficiency and control with the desire for great-tasting food. For four decades, Eloma

More information

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Ultra low temperature freezers -40 C and -86 C. NEXUS Series Our experience in biomedical cold storage c For over 80 years Angelantoni has been producing a full range of freezers for the long-term preservation of biological samples used in scientific laboratories,

More information

New standard in compressed air treatment, providing Energy Savings up to 99%

New standard in compressed air treatment, providing Energy Savings up to 99% PCM Series Specification for APAC Model Flow Capacity (Nm 3 /min) Pressure Dew Point ( ) Power Consumption (kw) Power Supply (V/Ph/Hz) Inlet/Outlet Connections Weight (kg) Dimensions (H x W x D mm) Refrigerants

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Paraffin Wax Embedding Centre MPS/P1 INS1000GB 12-2010-04 Instructions MPS/P1 1 Instructions MPS/P1 2 CONTENTS 1. INTENDED USE... 4 2. SYMBOLS... 4 3. SAFETY NOTES... 4 4. COMPONENTS...

More information

Soxtec 200 series Solvent Extraction Solution

Soxtec 200 series Solvent Extraction Solution Soxtec 200 series Solvent Extraction Solution Labtec Line Soxtec solvent extraction systems for safe, convenient and economical determination of soluble, or extractable, matter. Typically five times faster

More information

HydroFlex FLEXIBLE AND RELIABLE MICROPLATE STRIP WASHING AND VACUUM FILTRATION IN A COMPACT, MODULAR PLATFORM. 21 CFR Part 11* 98/79/EC IVD-D*

HydroFlex FLEXIBLE AND RELIABLE MICROPLATE STRIP WASHING AND VACUUM FILTRATION IN A COMPACT, MODULAR PLATFORM. 21 CFR Part 11* 98/79/EC IVD-D* HydroFlex FLEXIBLE AND RELIABLE MICROPLATE STRIP WASHING AND VACUUM FILTRATION IN A COMPACT, MODULAR PLATFORM 21 CFR Part 11* 98/79/EC IVD-D* 02 3-in-1 microplate strip washing for 96-well plates The HydroFlex

More information

Lablyo Plus. Frozen in Time Ltd. Operating Manual

Lablyo Plus. Frozen in Time Ltd. Operating Manual Frozen in Time Ltd Manufacturers of Freeze Drying Machines and Vacuum Cold traps Operating Manual Lablyo Plus Main associated accessories: Acrylic drying chamber FIT/LYO/01/0 6 height shelf rack FIT/LYO/03/0

More information

Cryogenic cooling with CUMULUS LF.

Cryogenic cooling with CUMULUS LF. Cryogenic lyophilisation Cryogenic cooling with CUMULUS LF. Improved performance, high reliability and low maintenance for your lyophilisers. 02 Improving performance of freeze dryers with cryogenic cooling.

More information

MiniWAVE Microwave Digestion Made Easy

MiniWAVE Microwave Digestion Made Easy SCP SCIENCE Providing Innovative Solutions to Analytical Chemists MiniWAVE Microwave Digestion Made Easy Order one controller and up-to four digestion modules Powered by a 1000 Watt magnetron Compressed

More information

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION ARCTIKO CONTROLLER At Arctiko we have the customer in mind when engineering new technologies. With the large

More information

ICP450. Compressor-cooled incubator. Product specification

ICP450. Compressor-cooled incubator. Product specification Product specification Compressor-cooled incubator ICP450 Ideal for ramp operation with rapid temperature changes during incubation, breeding or storage. With the help of our model selection, with dimensioned

More information

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure Advancing the power of SPE Intelligent Automated Solid Phase Extraction SmartPrep Brochure SmartPrep Extractor: Simplify Cartridge-based Solid Phase Extraction Unprecedented versatility SmartPrep is the

More information

Vacuum Insulated Pipe

Vacuum Insulated Pipe Product Catalog Innovation. Experience. Performance. Vacuum Insulated Pipe Ensuring liquid supply capabilities. Any application - Any time Ensuring liquid supply capabilities. Any application - Any time

More information

-86 C Ultra-Low Freezers. How It s Made. Matters

-86 C Ultra-Low Freezers. How It s Made. Matters -86 C Ultra-Low Freezers How It s Made Matters How It s Made Matters Designing an Ultra-Low Freezer You Can Trust for Your Sample Storage Understanding How It s Made Matters was the tenet around which

More information

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig Screw Compressors AS SERIES Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig Rotary Screw Compressor Maximum Reliability and Efficiency For years, customers have relied on Kaeser for reliable

More information

COMPLETELY AUTOMATED HYDROLYSIS

COMPLETELY AUTOMATED HYDROLYSIS HYDROTHERM for classic fat determination according to Weibull-Stoldt COMPLETELY AUTOMATED HYDROLYSIS EFFICIENT SAFE VALID FLEXIBLE CONVENIENT Up to 80 % cost savings per sample Process runs in closed system

More information

Advances in Liquid Nitrogen (LN 2 ) Based Lyophilization Technologies

Advances in Liquid Nitrogen (LN 2 ) Based Lyophilization Technologies Advances in Liquid Nitrogen (LN 2 ) Based Lyophilization Technologies Alan Cheng, Ph. D. Application R&D Manager Biopharma & Biochemicals Praxair Inc. 7000 High Grove Blvd. Burr Ridge, IL., USA Presented

More information

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF Deep Freezers and Plasma Storage Freezers Biomedical Refrigeration I FR / MF Low-temperature storage of plasma and other blood products at 41 C/ 35 C According to DIN 58375 www.dometic.lu Deep Freezers

More information

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE TECHNOLOGY FOR LIFE DEEP FREEZERS AND PLASMA STORAGE FREEZERS Biomedical Refrigeration I FR / MF Low-temperature storage of plasma and other blood products at 41 C/ 35 C According to DIN 58375 www.dometic.lu

More information

SubliMate. Bench Top Laboratory Freeze Dryers. SubliMate Bench Top Laboratory Freeze Dryer Model FDL-5

SubliMate. Bench Top Laboratory Freeze Dryers. SubliMate Bench Top Laboratory Freeze Dryer Model FDL-5 SubliMate Bench Top Laboratory Freeze Dryers SubliMate Bench Top Laboratory Freeze Dryer Model FDL-5 SmarTouch TM : Large Touchscreen Control Technology Touchscreen controller equipped with a user-friendly

More information

Upright Chromatography Refrigerators

Upright Chromatography Refrigerators Our ULTRA, ULTRA ELITE, and ULTRA TOUCH Series Chromatography Laboratory are designed to provide proper optimal temperature conditions for all chromatography applications. Each model features covered access

More information

Reproducible Climate...

Reproducible Climate... Reproducible Climate...... the new standard in test technology Temperature and Climatic Test Chambers VT 3 & VC 3 Reliable test results... Your adviser for environmental test technology... Characteristics,

More information

Operator s Manual. Histology Bath

Operator s Manual. Histology Bath Operator s Manual Histology Bath 110-827 05.09.12 Table of Contents Introduction... 2 General Safety Information... 2 Safety Recommendations... 3 Unpacking Your Histology Bath...4 Contents...4 Components

More information

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps CentriVap Centrifugal Vacuum Concentrators and Cold Traps 2 CENTRIVAP VACUUM CONCENTRATORS & COLD TRAPS Page An Overview 2 CentriVap Benchtop Vacuum Concentrators 4 Refrigerated CentriVap Vacuum Concentrators

More information

A Chiller is equipment to control temperature of customers heating sources. Application Examples

A Chiller is equipment to control temperature of customers heating sources. Application Examples Control Equipment What s a Chiller? A Chiller is equipment to control temperature of customers heating sources. Chillers control, such as water, and circulate the to customers machine using a pump by controlling

More information

Bio System Installation

Bio System Installation Bio System Installation Molecular Collection Facility, Natural History Museum London. The Project Installation of a complete Cryogenic storage facility for the storage of samples from endangered species.

More information

HOT BAR REFLOW SOLDERING FUNDAMENTALS by Amada Miyachi Europe A high quality Selective Soldering Technology

HOT BAR REFLOW SOLDERING FUNDAMENTALS by Amada Miyachi Europe A high quality Selective Soldering Technology HOT BAR REFLOW SOLDERING FUNDAMENTALS by Amada Miyachi Europe A high quality Selective Soldering Technology Content 1. Hot Bar Reflow Soldering Introduction 2. Application Range 3. Process Descriptions

More information

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION Visit us at www.lctech.de! What LCTech does supplies innovative products and methods for the preparation and analysis of food,

More information

Daikin LXE10E Technical Information

Daikin LXE10E Technical Information Daikin LXE10E Technical Information Model shown above is the DAIKIN LXE10E-A15 (Fitted with Transfresh Provision option.) Page 1 of 9 23/11/2006 The most important part of any refrigeration machine is

More information

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes. HYDRIM C51wd The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes. Safer for your staff, kinder to your instruments. HYDRIM WASHER DISINFECTOR

More information

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous RapidTrace + Automated SPE Workstation Instruments RapidTrace + Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous Automate Your Extractions Increase your throughput and productivity The

More information

New. ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1

New. ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1 New ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1 With natural refrigerants Panasonic Healthcare s VIP ECO delivers more energy efficient

More information

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig Screw Compressors SM SERIES Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig Rotary Screw Compressor Maximum Reliability and Efficiency For years, customers have depended on Kaeser for reliable

More information

INCREASE YOUR LAB EFFICIENCY

INCREASE YOUR LAB EFFICIENCY INCREASE YOUR LAB EFFICIENCY CoolSafe How to configure your freeze dryer Scandinavian by Design THE PROCESS PRE-FREEZING, PRIMARY DRYING & SECONDARY DRYING THE BASIC PRINCIPLE: Freeze drying is a process

More information

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform HydroFlex 3-in-1 microplate strip washing Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform 21 CFR Part 11* 98/79/EC IVD-D* HydroFlex the 3-in-1 microplate

More information

Thermo Scientific CryoStar NX50 Operator Guide Issue 2.0

Thermo Scientific CryoStar NX50 Operator Guide Issue 2.0 Thermo Scientific CryoStar NX50 Operator Guide 388149 Issue 2.0 Company Information 2 Thermo Scientific NX50 Company Information Company Information Copyright 2013. Thermo Fisher Scientific Inc. All rights

More information

BLAST CHILLERS & BLAST CHILLER/FREEZERS

BLAST CHILLERS & BLAST CHILLER/FREEZERS BLAST CHILLERS & BLAST CHILLER/FREEZERS Why Do You Need A Blast Chiller/Freezer? Poor cooling techniques are a major cause of foodborne illness. To avoid contamination, food must be cooled through the

More information

Peace of milk S M A R T M I L K C O O L I N G

Peace of milk S M A R T M I L K C O O L I N G Peace of milk S M A R T M I L K C O O L I N G EXPERTS IN MILK COOLING Smart Milk Cooling Experts in cooling and milk Packo Cooling has been designing and producing milk cooling tanks in Belgium, Ireland

More information

UHV Flow Cryostats. Ultra High Vacuum Flow cry stats CRYO INDUSTRIES

UHV Flow Cryostats. Ultra High Vacuum Flow cry stats CRYO INDUSTRIES UHV Flow Cryostats Ultra High Vacuum Flow cry stats INDUSTRIES Ultra High Vacuum Flow Cryostats: Models RC-102 and RC-110 Cryo offers Models RC-102 and RC-110 Ultra High Vacuum continous flow cryostats,

More information

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs VWR LABORATORY REFRIGERATORS AND FREEZERS Versatile Storage Options Designed for Your Needs Going Green. What does it mean? The Advantages of Hydrocarbon Refrigerants 45-60% DECREASE IN REFRIGERANT CHARGE

More information

Shandon Excelsior Tissue Processor The new center of excellence in tissue processing.

Shandon Excelsior Tissue Processor The new center of excellence in tissue processing. 1 Shandon Excelsior Tissue Processor The new center of excellence in tissue processing. Histology 2 remote alarms signal possible problems. Automatic underfill recovery finishes processing in the safest

More information

QAQC LABS ANALYTICAL DRYING

QAQC LABS ANALYTICAL DRYING WHAT IS FLUID BED? By forcing enough air through a bed of particles, the particle bed may assume a fluid-like state (resembling a boiling liquid). Heating the incoming air and managing air flow rate through

More information

ULTRA.GUARD ultra low temperature freezer

ULTRA.GUARD ultra low temperature freezer UF V series 700 Ultra low temperature freezers ULTRA.GUARD ultra low temperature freezer The new BINDER ULTRA.GUARD ultra low temperature freezer ensures safe long-term storage of samples at -86 C. This

More information

Limited floor space. Removes 4 liters of water Available with Stoppering in 24 hours* Tray Dryer

Limited floor space. Removes 4 liters of water Available with Stoppering in 24 hours* Tray Dryer Selection Guide System Style Application -50 C (-58 F) -84 C (-119 F) Capacity Requirements and Collector/ Cascade Collector/ User Preferences Refrigeration Refrigeration For aqueous samples Optional PTFE-coated

More information

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION INSTRUCTION MANUAL FOR Freeze Dry Systems FDL-10N-50 series PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.VER.01-04.10

More information

Electrolux Professional. Range Overview Multi-Housing Laundry

Electrolux Professional. Range Overview Multi-Housing Laundry Range Overview Multi-Housing Laundry It starts with washing and ends with savings A turnkey laundry solution from Electrolux Professional is a profit centre. Benefit from exceptional performance, longer

More information

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators BR I Blood Bank Refrigerators 9.9707.50 09/015 > Legally safe storage of blood at +4 C > In compliance with international standards and directives BIOMEDICAL REFRIERATION Innovative and reliable refrigeration

More information

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific Thermo Scientific Heratherm Microbiological Incubators safe easy efficient Part of Thermo Fisher Scientific Thermo Scientific Heratherm Microbiological Incubators your samples We are obsessed with sample

More information

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor NEX-BETA-ABG FACILITY Drinking Water Safety Monitor FEATURES: DETECTS ALPHA, BETA AND GAMMA RADIATION AVAILABLE IN PORTABLE OR INSTALLED VERSION MEASURES AT OR BELOW EPA/DHS PAG LEVELS PROTECTIVE ACTION

More information

GEA A-Tec spiral freezers and chillers. In touch with GEA Refrigeration Technologies hygienic food processing. GEA Refrigeration Technologies

GEA A-Tec spiral freezers and chillers. In touch with GEA Refrigeration Technologies hygienic food processing. GEA Refrigeration Technologies GEA A-Tec spiral freezers and chillers In touch with GEA Refrigeration Technologies hygienic food processing engineering for a better world GEA Refrigeration Technologies GEA Refrigeration Technologies

More information