UHV Flow Cryostats. Ultra High Vacuum Flow cry stats CRYO INDUSTRIES
|
|
- Melinda Parks
- 5 years ago
- Views:
Transcription
1 UHV Flow Cryostats Ultra High Vacuum Flow cry stats INDUSTRIES
2 Ultra High Vacuum Flow Cryostats: Models RC-102 and RC-110 Cryo offers Models RC-102 and RC-110 Ultra High Vacuum continous flow cryostats, which feature rotatable Conflat interface flanges, your choice of 2.75, 4.50 or 4.62 etc.. Distance from chamber interface to cold finger can be selected to fit exactly your chamber. Constructions is all welded stainless steel with low vapor pressure silver brazed copper joints. The Model RC-110 offers the most advanced technology, resulting in better temperature stability. This is achieved with the addition of an internal metallized phase seperator which eliminates all temperature fluctuations. The Model RC-110-UHV has a heater assembly built on the end of the transfer line. This heater is not exposed to vacuum and is instantly accessible. (Note: The phase seperator is not installed in this model). An optional heater that mounts directly to the inside of the sample mount is available for the model RC102; this heater is accessible through a mini Conflat flange. The standard variable temperature continuous flow ultra high vacuum cryostat Models RC-102 and RC-110 feature the following: Operates with either Cryogen-10K Cryogenic Generator or Liquid Helium dewar Sample in ultra high vacuum (UHV) 4.5 inch rotateable conflat flange 1.00 inchy diameter copper sample mount with (6) #4-40 tapped holes on 0.75 diameter BC Vapor cooled radiation shield Hi Power (50 Ohm) heater installed on sample mount 0.62 inch O.D. helium vent/return port Temperature Range: Cooldown Time: Cooldown Consumption: Cryogen Consumption: Refrigeration Capacity: Temperature Stability: Orientation: Specifications (2-4) 1.33 inch mini conflat feedthrough ports (depending on style) Evacuation valve with NW25 interface flange Safety pressure relief on vacuum space Flexible stainless steel transfer line with flow control valve for operation with LHe dewar Silicon Diode Temperature Sesnor- bolt on style installed on sample mount < K (600 K optional) 10 minutes typical from 300 to 4.2 K (helium) 8 minutes typical from 300 to 77 K (nitrogen) 0.20 liters liquid helium from 300 to 4.2 K 0.55 liters/hour (helium) at 4.2 K for RC liters/hour (helium) at 4.2 K for RC-110 Lower at higher temperatures liters/hour (nitrogen) at 77 K Over 2 watts at 4.2 K 0.05 K for RC K for RC-110 Any Position
3 Standard Model RC-102 UHV WITH NW O.D. FLOW VALVE CONTROL KNOB CONTROL TUBE AND (4) 1.33 MINI CONFLAT PORT 4.50 (4.62 or 2.75 OPTIONAL) ROTATABLE CONFLAT FLANGE O.D or 0.37 O.D DIA. VAPOR COOLED RADIATION SHIELD 1.50 I.D. WITH (6) #4-40 TAPPED HOLES ON A 0.75 DIA BC PROPRIETARY INFORMATION IS THE SOLE PROPERTY OF TITLE: MODEL RC102-UHV
4 Standard Model RC-110 UHV EVACUATION VALVE WITH NW-25 FLANGE PHASE SEPARATOR REGULATOR FLOW VALVE CONTROL KNOB LIQUID HELIUM FLOW VALVE CONTROL TUBE AND (4) 1.33 MINI CONFLAT PORT O.D. ROTATABLE CONFLAT FLANGE (OTHER SIZE CONFLATS OPTIONAL) 1.0 O.D. HELIUM INNER TRANSFER 12.0 OR 2.31 DIA. THERMAL ANCHOR WITH WIREWAYS 12.0 OR 1.50 I.D. VAPOR COOLED RADIATION SHIELD (OPTIONAL) WITH (6) #4-40 TAPPED HOLES ON A 0.75 DIA BC PROPRIETARY INFORMATION IS THE SOLE PROPERTY OF TITLE: MODEL RC110-UHV
5 Model RC-102 UHV 4-PIN ELECTRICAL FEEDTHROUGH WITH NW-25 VALVE CONTROL KNOB CONTROL TUBE (4) 1.33 MINI CONFLAT PORT 4.50(4.62 or 2.75 OPTIONAL) ROTATABLE CONFLAT FLANGE O.D or 1.88 DIA. SINGLE THREAD INTERFACE VAPOR COOLED RADIATION SHIELD WITH (6) #4-40 TAPPED HOLES ON A 0.75 DIA BC NOTE: THIS STYLE RC-110 IS A NON-PHASE SEPERATOR DESIGN PROPRIETARY INFORMATION TITLE: MODEL RC102-UHV IS THE SOLE PROPERTY OF ULTRA HIGH VACUUM
6 Model RC-102 UHV WITH NW PIN ELECTRICAL FEEDTHROUGH FOR HEATER AND TEMP. SENSOR 10-PIN ELECTRICAL FEEDTHROUGH FOR HEATER AND TEMP. SENSOR VALVE CONTROL KNOB (3) BLANK 1.33 MINI CONFLAT PORTS CONTROL TUBE 4.50 ROTATABLE CONFLAT FLANGE O.D O.D O.D. VAPOR COOLED RADIATION SHIELD (2) 1.33 MINI CONFLAT FLANGES FOR ACCESS TO HEATER AND SENSOR WITH (4) #4-40 TAPPED HOLES ON A 0.75 DIA BC PROPRIETARY INFORMATION IS THE SOLE PROPERTY OF TITLE: MODEL RC102 ULTRA HIGH VACUUM
7 Example of Custom RC-110 UHV with 72 inch Leg 72.0" MIN. HOSE WITH NW PIN ELEC. FEEDTHRU FOR INTERNAL HEATER AND SENSOR VALVE CONTROL KNOB ROTATABLE QUICK 1.50 CONNECT SEAL WITH NW40 FLANGE (266.7mm) WITH NW16 FLANGE TYP. TYP. (1) 10 PIN ELECTRICAL UHV FEEDTHRU CONTROL TUBE.394 (10mm) 2.69 (68.3mm) 4.50 O.D. (114.3mm) 2.95 (75mm) (1) 1.33 DIA. TAPPED CONFLAT FLANGE (5) 1.33 DIA. TAPPED CONFLAT FLANGES SPACED AS SHOWN ON A 3.50 DIA. B.C (SPECIAL LENGTH) 0.86 (21.9mm) 2.37 I.D. (60.2mm I.D.) 0.75 (19.1mm) 4.50 O.D. ROTATABLE CONFLAT FLANGE (993.1mm) A 1.00 O.D. (25.4mm) 2.05 O.D., (8) M3 TAPPED HOLES ON A 1.81" (46mm) B.C., ALSO HAS (3) 1mm I.D. HOLES ON A 34mm B.C. (120 DEGREES APART) A VIEW A-A (3) 1mm (.039") DIA HOLES EQ. SP. ON A 34.0mm B.C NOTE: HOLES TO ORIENT WITH M3 TAPPED HOLES ON THE SAMPLE MOUNT AS SHOWN IN VIEW B-B 6.00 (2) 1.33 MINI CONFLAT FLANGES FOR ACCESS TO HEATER AND SENSOR VIEW B-B B B WITH INTERNAL HEATER AND SENSOR, EXTERNAL SENSOR AND (8) M3x.5 TAPPED HOLES ON A 19.05mm DIA. B.C. PROPRIETARY INFORMATION TITLE: IS THE SOLE PROPERTY OF MODEL RC110-UHV ULTRA HIGH VACUUM <2 K to 325 K operating temperature range Operates with liquid helium or liquid nitrogen Operates in Push or Pull modes Heater installed inside sample mount (Not in UHV) Total of (6) UHV (16 CF) tapped conflat ports Customized number of UHV feedthrough ports with mate Customized addition of gas inlet port Copper radiation shield interface flange Bakeable to 200 C System Features Include: Vacuum insulated LHe transfer line with activated charcoal cryopump, ice filter and flow control valve Size of rotatable conflat interface flange is customized Distance from conflat flange to sample mounting surface is customized Constructed of non-magnetic stainless steel SD Silicon Diode temperature sensor installed on sample mount (on UHV side) Fully integrated and liquid helium tested
2-Stage 4 K Closed Cycle Refrigerator Systems
CRYO 2-Stage 4 K Closed Cycle Refrigerator Systems Variable Temperature Closed Cycle Refrigerator Systems Cryo Industries manufactures closed cycle cryogenic workstations for a large variety of experimental
More information2-Stage 4 K Closed Cycle Refrigerator Systems
2-Stage 4 K Closed Cycle Refrigerator Systems Variable Temperature Closed Cycle Refrigerator Systems Cryo Industries manufactures closed cycle cryogenic workstations for a large variety of experimental
More informationApplications and Accessories, Cryo Pumps
General Applications and Accessories, Cryo Pumps Cryo pumps Application UHV systems Beam tubes in particle accelerators Transfer chambers / Loadlock General research Evaporation coating systems Sputtering
More informationCryopumps, Cryogenics
Cryopumps, Cryogenics 182.01.02 Excerpt from the Product Section C12 Edition 2010 Contents General Applications and Accessories Cryopumps........................................ C12.03 Cryogenics........................................
More information3.5 Cryosurface & Cryogenic Feed-through Specification
3.5 Cryosurface & Cryogenic Feed-through Specification The tubing, cryosurfaces, and feed-through must be free of oil and moisture before connecting it to the refrigeration unit. Failure to comply with
More informationCryogenics for Neutral Beam Injector System
Cryogenics for Neutral Beam Injector System Ch. Chakrapani, S.K.Sharma, A.K.Chakraborty, B.Sridhar, Vishnu.B. Patel, Siddharth Sheth, N.V.M.Rao, Mainak. B, G.B.Patel, M.J.Singh Janardhan.U, S.Rambabu,
More informationD R A F T. Testing of performance of precooling refrigerator in the fill/vent line at Indiana. Revision: 0.00
D R A F T Testing of performance of precooling refrigerator in the fill/vent line at Indiana Revision: 0.00 Prepared: Z. Tang, Indiana University, Nov- 10-2011 Checked: Hermann, Nann, Indiana University,
More informationFiber Optics. VIS / NIR Multimode, Feedthroughs. Ultrahigh Vacuum CF Flange Feedthrough. 4 x 1 CF Flange Feedthrough
VIS / NIR Multimode, Feedthroughs CCU-GLSS Ultrahigh Vacuum CF Flange Feedthrough 0.950 1.250 133 CF 275 CF 105020, UHV CF Flange 0.85 feedthrough circle Premium SM 905 Number Fiber Connector CF Flange
More informationConcept of a Powerful Cryogen-Free Dilution Refrigerator with Separate 1K Stage
Concept of a Powerful Cryogen-Free Dilution Refrigerator with Separate 1K Stage Kurt Uhlig Walther-Meissner-Institute Garching 85748, Germany ABSTRACT Helium-3,4 dilution refrigerators (DR) are the workhorses
More informationCOOLVAC
Vacuum Solutions Application Support Service LEYBOLD VACUUM GA 12.123/3.02 COOLVAC 800 1500 3000 Refrigerator Cryopumps Cat. Nos 892 61/63 892 56 893 21/23 Operating Instructions Description Contents Page
More informationFast Cycle Water Vapor Cryopump
Polycold PFC 1101 LT Fast Cycle Water Vapor Cryopump VACUUM Benefits -145 to -155 C Heat Removal to 800 Watts Cryocondenses Water Vapor in Vacuum Systems with Speeds to 50,000 l/sec Vacuum Levels to 2
More information4.8 FARADAY CUP ASSEMBLY OPTION
4.8 FARADAY CUP ASSEMBLY OPTION The Faraday cup assembly, mounted on the front end of the Electron Gun, is positioned by either a rotary feedthrough or a pneumatic actuator assembly, located on one of
More informationThe dilution process. 4K flange. Still. Heat exchangers. Mixing chamber
cryogenic systems CRYOCONCEPT has been supplying dilution refrigerators since 2000. In partnership with the low temperature department of the CEA located in Saclay (France), our company adjusted and improved
More informationFast Cycle Water Vapor Cryopump
SEMICONDUCTOR PRODUCTS GROUP Polycold PFC Fast Cycle Water Vapor Cryopump VACUUM PRODUCTS Benefits Marked for European Application Refrigerants Compliant to EC 2037/2000, the Montreal protocol, and the
More informationSpinTron 2: 2-inch High Vacuum Magnetron Sputter Source Product Installation and Use
www.directvacuum.com www.micromagnetics.com Micro Magnetics, Inc. 421 Currant Road, Fall River, MA 02720 Phone: (508)672-4489 admin@micromagnetics.com SpinTron 2: 2-inch High Vacuum Magnetron Sputter Source
More information2016 Ideal Vacuum (505) V 1.1
Doc. Ref. IdealCUBE-6x121416 pg. 1 User Manual Table of Contents 6x6x6 Vacuum Cube Specification Sheet...3 Assembling a Vacuum Cube system...3 Vacuum Cube Frame...3 Plate Installation...4 Mounting for
More informationWHAT ARE THE SPECIFICATIONS FOR THE VACUUM
WHAT ARE THE SPECIFICATIONS FOR THE VACUUM PUMPS NEEDED TO OPERATE THE JOULE THOMSON REFRIGERATORS? INTRODUCTION TO VACUUM PUMP USAGE Joule Thomson refrigerators have a wide temperature range to operate
More informationVACUUM VALVES AND HOSES
VACUUM VALVES AND HOSES 5046 Vacuum Valve Two-piece 500 F (260 C) industry standard 5255 Vacuum Valve Three-piece 500 F (260 C) industry standard SS5700 Stainless Steel Vacuum Valve Three-piece 1000 F
More informationVariable Temperature Microprobe Systems
Variable Temperature Microprobe Systems the world s resource for variable temperature solid state characterization 2 The Variable Temperature Microprobe System The variable temperature microprobe system
More informationVacuum Insulated Pipe
Product Catalog Innovation. Experience. Performance. Vacuum Insulated Pipe Ensuring liquid supply capabilities. Any application - Any time Ensuring liquid supply capabilities. Any application - Any time
More informationthermal management features such as temperature setpoint control, temperature ramp rate control, and process heating.
POLYCOLD MAXCOOL 4000 H CRYOCHILLER Water Vapor Cryotrapping Applications How do I select the right model of MaxCool to trap water vapor in my vacuum chamber? Determining the appropriate MaxCool system
More informationINNOVATIVE WATER VAPOR CRYOPUMP TECHNOLOGIES PRODUCT CATALOG
INNOVATIVE WATER VAPOR CRYOPUMP TECHNOLOGIES PRODUCT CATALOG INNOVATIVE HV/UHV CRYO PUMPING TECHNOLOGIES NO MORE SPACE AND POWER HUNGRY COMPRESSORS! Ricor's new, more compact, single stage water vapor
More informationInstruction Manual. B Issue B. next Pump Accessories
Instruction Manual B811-00-880 Issue B next Pump Accessories This page has been intentionally left blank. Contents Section Page 1 Introduction... 1 Contents gea/0086/06/10 1.1 Scope and definitions...
More informationW A T L O W. Straight Resistance Wire. Welded End Cap
W A T L O W The versatile Watlow cable heater can be formed to a variety of shapes as dictated by its many applications. Cable heaters are small diameter, high performance units, fully annealed and readily
More informationVacuum Equipment. Manifolds. Traps. Pumps. Adapters. Easy to assemble Ace-Safe connector versions. O-Ring connections. Added safety and versatility
Adapters g Pumps g Traps Vacuum Equipment Manifolds Easy to assemble Ace-Safe connector versions O-Ring connections Added safety and versatility Comp act 2 Vacuum Manifolds 7818 ACCESSORIES 7818 Vacuum
More informationPocket Dilution Cooler
Pocket Dilution Cooler T. Prouvé, N. Luchier, L. Duband CEA/DSM/INAC/SBT Grenoble, 38054 Cedex 9, France ABSTRACT We have developed a compact, self-contained dilution cooler that can be operated from a
More informationModifications and Improvements to the NPDGamma Liquid Hydrogen Target System and Safety
Modifications and Improvements to the NPDGamma Liquid Hydrogen Target System and Safety Prepared: H. Nann, Indiana University, November 01, 2011 Checked: S. Penttila, ORNL, November 01, 2011 Approved:
More informationW A T L O W. Straight Resistance Wire. Welded End Cap
W A T L O W The versatile Watlow cable heater can be formed to a variety of shapes as dictated by its many applications. Cable heaters are small diameter, high performance units, fully annealed and readily
More informationScientific vapor pumps
Scientific vapor pumps Vapor pumps for scientific instruments and R&D applications Diffusion pumps - technology and applications - EO series -4 Diffstak -8 Cryo cooled diffstak - Unvalved diffstak -6 Diffstak
More informationA Microcryostat for Refrigeration at 1.8 K
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH European Laboratory for Particle Physics Large Hadron Collider Project LHC Project Report 231 A Microcryostat for Refrigeration at 1.8 K A. Bouyaya *, C. Policella,
More informationVarian, Inc. Vacuum Technologies. Diffusion Pumps. Feature and Benefits Typical Applications Pump Models
Varian, Inc. Vacuum Technologies Diffusion Pumps Feature and Benefits 62-63 Typical Applications 64-65 Pump Models 66-89 Fluids 9-91 Baffles 92-94 Technical Notes 96-99 61 Diffusion Pumps Features and
More informationThermal Vacuum Cycling Test Facility for the Qualification of Near Sun Missions Solar Panels
Volume 118 No. 16 2018, 1291-1308 ISSN: 1311-8080 (printed version); ISSN: 1314-3395 (on-line version) url: http://www.ijpam.eu ijpam.eu Thermal Vacuum Cycling Test Facility for the Qualification of Near
More informationAGILENT ION PUMP 200 The first ion pump with maximum pumping speed at low pressure
Technology Innovation from the Leader in Ultra-High Vacuum AGILENT ION PUMP 200 The first ion pump with maximum pumping speed at low pressure The new Agilent Ion Pump 200 Technology Innovation from the
More informationDART-Thermo LTQ/Orbitrap Interface Manual
DART-Thermo LTQ/Orbitrap Interface Manual For Thermo LTQ (Orbitrap) Velos, LTQ Orbitrap XL, LTQ Ion Trap, Exactive High Performance, and all other instruments that utilize the Ion Max Source Version 20120423
More informationDesign and Operation of a Cryogenic Nitrogen Pulsating Heat Pipe
IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Design and Operation of a Cryogenic Nitrogen Pulsating Heat Pipe To cite this article: Luis Diego Fonseca et al 2015 IOP Conf.
More informationFinal Design Report. for the M.I.C.E. 2 slot VLPC Cryocooler Cryostat
Final Design Report for the M.I.C.E. 2 slot VLPC Cryocooler Cryostat D-ZERO ENGINEERING NOTE # 3823.000-EN-579 Dec. 13, 2005 Authors: Russell A. Rucinski Alan Bross PPD/MD/D0 Operations Fermi National
More informationCustom Products Gallery
Custom Products Gallery KEY HIGH VACUUM PRODUCTS, INC., willingly customizes its standard product line to meet individual customer specifications. Customized products include but are not limited to, valves,
More informationWhat is an Integrated Detector Assembly? Aron Traylor. College of Optical Sciences The University of Arizona 29 November 2010.
What is an Integrated Detector Assembly? Aron Traylor College of Optical Sciences The University of Arizona 29 November 2010 Traylor 1 Various IDA s Traylor 2 Why are they used? Integrated Detector Assemblies
More information1.0 Denton Thermal Evaporator
1.0 Denton Thermal Evaporator View port shutter knob Touch screen View port Vacuum chamber Thickness monitor EMO Switch 1.1 Introduction Figure 1: Denton Thermal Evaporator. Denton Thermal Evaporator is
More information3.2 Cryoplant and Cryodistribution
3.2 Cryoplant and Cryodistribution 3.2.1 System Description 1 3.2.1.1 Cryoplant 1 3.2.1.2 LHe Plant 4 3.2.1.3 80K He Loop and LN 2 Subsystem 5 3.2.1.4 Cryodistribution System 6 3.2.1.5 System of Cryogenic
More informationCan one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK
Can one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK 1 To small use coolers or not to use small coolers? That is the
More informationDESIGN STANDARDS SECTION 15600
PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating
More informationDescription of the Ortho-to-Para Convertor and Internal Plumbing of the Hydrogen Target
Description of the Ortho-to-Para Convertor and Internal Plumbing of the Hydrogen Target Prepared: M. Snow, Indiana University, March 08, 2011 Checked : H. Nann, Indiana University, October 25, 2011 Approved:
More informationLEIDEN CRYOGENICS BV
WWW.LEIDENCRYOGENICS.COM LEIDEN CRYOGENICS BV Leader in Low Temperature Techniques Cryogen-free models CF CS110 single or twin pulse tube system CF CS81 single pulse tube system CF CS50 single pulse tube
More informationVacIon Plus 150. Outline Drawing. Technical Specifications. Dimensions: millimeters (inches) 6" O.D. CFF (NW100) (1.88) REF (14.
VacIon Plus 150 Outline Drawing 6" O.D. CFF (NW100) 47.80 (1.88) REF 100 (3.94) REF 170 (6.69) REF 272.50 (10.73) REF 244.50 (9.62) REF 362.80 (14.28) REF THREADING 1/2"-20 2B 205 (8.07) REF Dimensions:
More informationTECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER
TECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER ULTRA ELECTRIC PASTA COOKER 1. ELECTRIC DIAGRAMS...3 1.1 PASTA COOKER...3 1.2 OPTION AUTOMATIC LIFTING...4 2. HYDRAULIC CIRCUITS...5 2.1
More informationXFEL Collimation and Beam Switchyard Vacuum Issues
The European Vacuum Issues Torsten Wohlenberg Beam Dynamic Meeting 1 general remarks Lengths of the vacuum system : Collimation: total length ~ 226m Beam Switchyard: total of TL+T1+T2~150m+132m+112m~394m
More informationSECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION
SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION UNIT OBJECTIVES After studying this unit, the reader should be able to Describe a standing pressure test. Choose a leak detector
More information92831 TEL: (714) FAX:
Document No. 1800-11 High-Performance Vacuum/Nitrogen Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton,
More informationLiquid Helium Level Instruments
Liquid Helium Level Instruments Versatile Reliable Affordable AMI American Magnetics, Inc. Excellence in Magnetics and Cryogenics Model 135 Liquid Helium Level Monitor... Sample-and-Hold Level Sensing
More informationSERVICE MANUAL FOR MODEL RM-10
SERVICE MANUAL FOR MODEL RM-10 REQUIRED TOOLS CORDLESS DRILL COPPER CUTTING TUBE 1/2 OPEN WRENCH SOLDERING IRON SCREWDRIVER SET WITH 9/32 SOCKET VISE GRIP PIERCING VALVE PRECISION FLAT BLADE SLOTTED SCREWDRIVER
More informationREVISION NO. 1 DATED SEPT 20/10 HIGHLIGHTS
COMPONENT MAINTENANCE MANUAL TO: HOLDERS OF THE FIRE EXTINGUISHER, DUAL OUTLET DUAL BYPASS SYSTEM 70 CUBIC INCH COMPONENT MAINTENANCE MANUAL,, DATED. REVISION NO. 1 DATED SEPT 20/10 HIGHLIGHTS THIS PUBLICATION
More informationMVE Chart Tech Tips PRODUCT INFORMATION MVE205AF GB
MVE Chart Tech Tips PRODUCT INFORMATION MVE205AF GB November 201 5 The MVE 205 freezer provides stable cryogenic storage for up to 3,200 1.2/ 2.0 ml vials. These freezers provide maximum storage density
More informationVacIon Plus 20. Outline Drawing. Technical Specifications
VacIon Plus 20 Outline Drawing 2 3/4 " CFF (NW35) 152 (6.00) REF 24 (0.90) REF 133 (5.20) REF 82 (3.20) REF 224 (8.80) REF 121 (4.80) REF Dimensions: millimeters (inches) Technical Specifications StarCell
More informationINLET PRESSURE - TORR
HS-2 Diffusion Pump Outline Drawing mm (inches).84 DIA O.D. (21.3) 6 (152.4) 4.78 (121.4) 12.69 (322) Speed Curve AIR SPEED (l/sec) 500 400 300 200 100 SPEED AT INLET OF PUMP SPEED AT INLET OF 325 CRYOTRAP
More informationCased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit
18-AD32D1-3 Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit Upflow models: 4PXCAU24BS3HAA 4PXCBU24BS3HAA 4PXCBU30BS3HAA 4PXCCU30BS3HAA 4PXCBU36BS3HAA
More informationcooled, Non-heated ATH 1603 M, DN 200 CF-F, External drive electronics, Water cooled, Non-heated
ATH 1603 M, DN 200 CF-F, External drive electronics, Water ATH 1603 M, DN 200 CF-F, External drive electronics, Water ATH 1603 M, DN 200 CF-F, External drive electronics, Water Similar Image 5-axis magnetically
More informationUlster Bank Business Achievers Award Emerging Technology
1 Ulster Bank Business Achievers Award 2009 - Emerging Technology Welcome to Provac Provac Ltd. was established in 1997 to supply vacuum equipment to Irish industry and the third level research community.
More informationCartridge. SORB-AC Cartridge Pumps MK5 Series. Pump Body. Heater. Thermocouple. Flange. Electrical Connector
SORB-AC Pumps MK5 Series The manufacturing companies are ISO9001 certified, the Asian and Italian companies are website at: NEW SORB AC PUMPS_Layout 1 28/07/2011 10.57 Pagina 1 SORB-AC Pumps MK5 Series
More informationModel MTD-120/121 Modular Test Dewar Cryotest System
User's Manual Model MTD-120/121 Modular Test Dewar Cryotest System Obsolete Notice: This manual describes an obsolete Lake Shore product. This manual is a copy from our archives and may not exactly match
More informationKurt J. Lesker in the Cryogenic Community. Dr. Glynn Dyson Cryogenics Cluster Day 19 th September 2014
Kurt J. Lesker in the Cryogenic Community Dr. Glynn Dyson 19 th September 2014 Overview Introduction to the Kurt J. Lesker Company (KJLC) KJLC in the Cryogenic Community Deposition Methods Axxis Coating
More informationPRODUCT OVERVIEW. Precision and Vacuum Technology.
PRODUCT OVERVIEW Precision and Vacuum Technology www.prevac.eu PREVAC was founded in Rogów (Upper Silesia, Poland) in 1996. Since its foundation PREVAC has been one of the world's leading manufacturers
More informationZD-985 Desoldering Station
ZD-985 Desoldering Station 2 Contents Contents... 3 Unpacking and Setting Up Your ZD-985 Desoldering Station... 4 Setting Up the Unit... 5 Auto Tip Saver Function... 8 Tips and Techniques... 8 Alloy Melt
More informationEarthLinked Series PHXTI Pool Heat Exchangers Installation Manual
EarthLinked Series PHXTI Pool Heat Exchangers Installation Manual CONTENTS PAGE Pre-Installation 3 Installation 3 Water Connections 4 Refrigerant Connections 7 Freeze Protection/Winterizing 11 PHXTI-IM
More informationMaintenance and Reliability Design Aspects SNS 2K Refrigeration System
Maintenance and Reliability Design Aspects SNS 2K Refrigeration System Dana M. Arenius, JLab Cryogenics Systems Group Donald Richied, SNS Cryogenics Systems Group Cryo2004 Operations Workshop March 29-April
More informationWater Circulator (Chiller) & Cold Trap
Yamato Scientific America Innovating Science for Over 125 Years Water Circulator (Chiller) & Cold Trap Contents Water Circulator (Chiller) Cold Trap CA Series Page Page 91 93 9 Water Circulator (Chiller)
More informationOwner s Manual. Terpene Trap CF 1000
Owner s Manual Terpene Trap CF 1000 IMPORTANT SAFETY INFORMATION: Please carefully read this manual before attempting to use your Terpene Trap. For your safety, comply with all safety instructions and
More informationCHASE RESEARCH CRYOGENICS Ltd. World Leaders in sub-kelvin cryogenics
CHASE RESEARCH CRYOGENICS Ltd. World Leaders in sub-kelvin cryogenics TWO-STAGE SUB-KELVIN 3 He CRYOCOOLER TYPE GL7 (Helium 7) GENERIC INSTALLATION AND OPERATING INSTRUCTIONS Photo shows a typical CRC
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.18
MODEL CMA-180UC PARTS MANUAL Rev 1.18 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS
More informationTech Tips (December 2016) Product Information
Tech Tips (December 2016) Product Information Variō Pro Controller Firmware Update Chart MVE has released a new firmware version for the Variō Pro controller. Version 0.23 will now replace 0.20 as the
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.16
MODEL CMA-180UC PARTS MANUAL Rev 1.16 CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS
More informationVariable Temperature Options for Optical Experiments
Variable Temperature Options for Optical Experiments the world s resource for variable temperature solid state characterization 2 The Variable Temperature Options for Optical Experiments MMR Technologies
More informationKarlsruher Glastechnisches Werk KGW-ISOTHERM
Karlsruher Glastechnisches Werk KGW-ISOTHERM Germany 76185 Karlsruhe Gablonzer Straße 6 Tel. 0049 / 721 / 95897-0 Fax. 0049 / 721 / 95897-77 E-Mail: info@kgw-isotherm.de Internet: kgw-isotherm.com Operating
More informationUltra-sorb Models LV and LH
Ultra-sorb Models LV and LH Steam Dispersion Panels Installation, Operation, and Maintenance Manual For applications using steam from a boiler or from any DRI-STEEM steam generating humidifier. Overview
More informationVacuum Quality Assurance in Practice
Vacuum Quality Assurance in Practice Matthew Cox Head of Vacuum Diamond Light Source 1 Topics What is Diamond Light Source? Why is vacuum QA important to Diamond? QA in vacuum vessel procurement Diamond
More informationDPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL
DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL MANUAL NUMBERS 517646-1960 517645-1960 517702-1960 517783-1960 Ultrak, Inc. 4465 Coonpath Road NW Carroll, OH 43112 (740) 756-9222
More informationRecirculating Coolers
09 Recirculating Coolers (chillers) General Recirculating Coolers Low Temp. Recirculating Coolers Advanced Low Temp. Recirculating Coolers High Temp. Recirculating Coolers Compact Recirculating Cooler
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION FLOOR /CEILING INDOOR UNIT MODEL: SMUL 12,18,24,30,36,48,60 Read this instructions carefully before installation. P. 12 P. 01 Dimemsion RHEEM REV 01 P. 02 P. 11 Detaching the mounting
More informationINSTALLATION INSTRUCTIONS
,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE
More informationChapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing
Do s & Don ts in Refrigeration & Air-Conditioning Servicing Who is Better? OR Common Practices that are damaging to the Refrigeration & Air-conditioning Systems Brazing with Cu electrode for brazing Cu
More informationF-T, FT-P, F-L AND F-P SERIES
F-T, FT-P, F-L AND F-P ERIE 2/3 JACKETED DIRECT TEAM TILTING & TATIONARY KETTLE INTALLATION - OPERATION - MAINTENANCE TILTING TRI-LEG TILTING PEDETAL TATIONARY TRI-LEG TATIONARY PEDETAL FT-L FT-30L FT-40L
More informationCased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**
18- AH44D1-4 Cased Aluminum "Convertible" Coils 4TXCB003CC3HC 4TXCB004CC3HC 4TXCC005CC3HC 4TXCC006CC3HC 4TXCC007CC3HC 4TXCC008CC3HC 4TXCD009CC3HC 4TXCD010CC3HC May be "A" or "B" ALL phases of this installation
More informationTable of Contents. Check the LCLS Project website to verify 2 of 12 that this is the correct version prior to use.
Table of Contents Summary...3 Mechanical Design Specifications...3 Vacuum...3 Materials...5 Support Requirements...5 Cabling...6 Light Path...6 BLM Synchrotron Radiation Assembly (BL11)...7 Other Requirements...9
More information2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA
18- AH39D1-4 Cased Aluminum "Convertible" Coils 2/4TXCA018BC3HCA 2/4TXCA024BC3HCA 2/4TXCB025BC3HCA 2/4TXCB031BC3HCA 4TXCB032BC3HCA 2/4TXCB036BC3HCA ALL phases of this installation must comply with NATIONAL,
More informationTechnology for Vacuum Systems. Instructions for use
page 1 of 8 Technology for Vacuum Systems Instructions for use GKF 1000i Cold trap page 2 of 8 Content Safety information!...3 General information...3 Intended use...3 Setting up and installing the cold
More informationA n hybrid liquid nitrogen system for the cooling. of the ESO O mega C A M detector
A n hybrid liquid nitrogen system for the cooling of the ESO O mega C A M detector J.L. Lizon*, A. Silber, G. Jakob European Southern Observatory, Karl-Schwarzschild-Strasse 2, 85748 Garching bei München,
More informationMINI BENCH TOP CHAMBER MODEL: MI-80-A-H
MINI BENCH TOP CHAMBER MODEL: MI-80-A-H Introduction: The Mini Bench top chambers are compact sized humidity chambers which can be placed on a work bench or on the optional stand provided. These chambers
More informationELD500 PRECISION LEAK DETECTOR
uvhts.com ELD500 PRECISION LEAK DETECTOR THE PARTNER OF CHOICE Edwards is a world leader in the design, technology and manufacture of vacuum pumps with over 95 years of history and more than 75 years of
More informationSERVICE MANUAL FOR MODEL RM-26
SERVICE MANUAL FOR MODEL RM-26 REQUIRED TOOLS CORDLESS DRILL DRIVE CUTTING TUBING OPEN WRENCH OF 1/2 RATCHET WITH SOCKET OF 7/16 SCREWDRIVER SET WITH SOCKET OF 9/32 VISE GRIP PIERCING VALVE WATCHER SLOTTED
More informationOwner s Manual Therma-Stor II Heat Recovery System
PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.
More informationOxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm
Oxygen Deficiency Monitor and Oxygen Analyzers Oxygen Sensors for 0-25% and 0-1000ppm Who is PureAire Monitoring Systems We are an industry leader in gas detection. Our mission at PureAire is simple. Keep
More informationInstallation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant
EarthLinked TXV Kit Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant CONTENTS PAGE Pre-Installation 3 Air Handler Conversion 4 System
More informationIon Pump Evolution. VacIon Plus. Titanium Sublimation Combination Pumps (TSP)
AGILENT ION 2-3 Ion Features and Benefits 4,5 Controllers Features and Benefits 6,7 SEM Pump Controller Features and Benefits 8-11 Typical Applications 12-40 Pump Models and Controllers 41-51 Technical
More informationVarian, Inc. Vacuum Technologies. Diffusion Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models Fluids
Varian, Inc. Vacuum Technologies Diffusion Pumps Features and Benefits 2-3 Typical Applications 4-5 Pump Models 6-29 Fluids 3-31 Baffles 32-33 Technical Notes 34-37 Diffusion Pumps Features and Benefits
More informationVickers. Service Data. Piston Pumps. PVH57/63 Variable Displacement Piston Pump - 11 Design M-2206-S. Revised 11/01/97
Service Data Vickers Piston Pumps PVH57/63 Variable Displacement Piston Pump - 11 Design Revised 11/01/97 M-2206-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque
More informationParts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3 hoshizakiamerica.com Number: 71375 Issued: 5-15-017 Revised: 10-3-018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationInstallation Manual PS-200 & PS-201
Installation Manual PS-200 & PS-201 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal
More informationScotsman Technical Training. CU50 Cube Ice Machine
Scotsman Technical Training CU50 Cube Ice Machine Major Topics Overview Installation Start Up Sequence of Operation Maintenance Diagnostics Service Procedures Models Two Base Models Gravity Drain Pump
More informationCartridge Heaters. Components. Application Guidelines
Application Guidelines Up to 1.297" Dia. Up to 60" Lengths Up to 11,500 Watts 120 and 240 Volt Up to 1400 F Max. Working Temp. Modification Available to Fit Custom Applications Type CIR cartridge heaters
More informationThermo-Finnigan LCQ Interface Manual
Thermo-Finnigan LCQ Interface Manual For Thermo Finnigan LCQ XP, Deca, Advantage, Duo, and Classic Models Version 20101129 IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906 Copyright 2005-2010 by IonSense
More information