GUIDE TO THE F-GAS REGULATION (EC 517/2014)
|
|
- Maria Hudson
- 6 years ago
- Views:
Transcription
1 GUIDE TO THE F-GAS REGULATION (EC 517/2014) Mexichem Fluor has been an active supporter of an appropriate revision to the previous EU F-Gas regulation (EC 842/2006) and believes that, while not ideal, the new F-Gas regulation (EC 517/2014) is workable and enables s to continue to be used while at the same time encouraging the use of lower GWP products. Mexichem Fluor will continue to support the implementation of the new regulation and help our customers to enhance their understanding of how the regulation affects them and provide guidance on making the right choice (technically and environmentally) going forward. This short guide is intended to be an aid to our customers in understanding the key facts about the new regulation and will be further updated if and when relevant new information becomes available. In addition our Mexichem Fluor sales team are ready to answer any question that you may have.
2 Summary of 2014 F-Gas Regulation (EC 517/2014) The new F-Gas regulation came into force in June 2014 and includes the gradual phase down in the placing on the market of hydrofluorocarbons (s) in the European Union % of baseline o o To implement the phase down, the Commission will allocate quotas (based on GWP) to Mexichem Fluor and the other individual producers and importers for placing the s on the market. The quota allocation to Mexichem Fluor and the other individual companies will be based on the quantities of hydrofluorocarbons they have produced or imported during the previous reference period. 11% of the quota allocation wil be set aside for new market entrants. The regulation exempts certain critical uses from the scope of the phase down, for example, in cases such as asthma metered dose inhalers and for military equipment. o The phase down will be supported by a number of product, equipment, service and maintenance bans (See table 2). The regulation strengthens the existing measures relating to the containment of fluorinated gases through recovery, leak reduction and repair, in addition to minimum training and certification requirements for companies and personnel working with equipment containing fluorinated gases. The regulation also includes restrictions on the use of recycled and reclaimed refrigerants. If you would like more information on this please contact the Mexichem Fluor sales team.
3 Table 1 Global Warming Potential (GWP) values for Mexichem s current range of KLEA refrigerants under the F-Gas Regulation. KLEA Refrigerant Typical applications 134a GWP above Composition 143a PFC 116 GWP (Tes CO 2 e) KLEA 32 Low and medium temperature refrigeration and air conditioning 100% 675 GWP above 750 KLEA 134a Medium temperature refrigeration and air conditioning 100% 1430 GWP above 1500 KLEA 407C KLEA 410A KLEA 407A Medium and high temperature chilling, refrigeration and air conditioning Medium and high temperature refrigeration and air conditioning Medium and low temperature refrigeration 52% 23% 25% % 50% % 20% 40% 2107 GWP above 2500 KLEA 404A Low temperature refrigeration applications 4% 52% 44% 3922 KLEA 507 KLEA 508 KLEA 23 Low temperature refrigeration applications Very low temperature biomedical applications Ultra low temperature refrigeration 50% 50% % 61% % Mexichem Fluor is developing a range of lower and low GWP refrigerants, for further information on these please contact your Mexichem Fluor sales representative
4 Table 2 Schematic of how the bans and prohibitions under the F-Gas Regulation effect the use of KLEA refrigerants in the different sectors and subsectors Ban or Prohibition Refrigeration Equipment Domestic refrigerators and freezers containing s with a GWP of 150 or more from 1st January 2015 Refrigerators and freezers for commercial use (hermetically sealed) that contains s with a GWP of 2500 or more from 1st January 2020 and with a GWP of 150 or more from 1st January 2022 KLEA 507 Stationary refrigeration equipment that contains or relies upon for its functioning s with a GWP of 2500 or more from 1 January 2020 KLEA 507 Stationary refrigeration equipment that is intended for applications designed to cool products to temperature below 50 o C. No ban or prohibition Centralised refrigeration systems for commercial use with a capacity of 40kW or more using fluorinated gases with a GWP of 150 or more, from 1 January 2022 Primary circuit cascades of centralised refrigeration systems for commercial use with a capacity of 40kW or more using fluorinated gases with GWP of 1500 of more, from 1 January 2022 Centralised refrigeration systems for commercial use with a capacity of less than 40kW. No ban or prohibition
5 Year Refrigeration Equipment KLEA 23 KLEA 508 KLEA 32 KLEA 507
6 Ban or Prohibition AC Equipment Movable room air-conditioning appliances (hermetically sealed) that contain s with GWP of 150 or more from 1 January 2020 Single split air-conditioning systems containing LESS than 3 kg of F-gases that contain F-gases with a GWP of 750 or more from 1 January 2025 Single split air-conditioning systems containing MORE than 3 kg of F-gases. No ban or prohibition Extruded polystyrene foams that contain s with a GWP of 150 or more, from 1 January 2020, except when required to meet national safety standards Other foams that contain s with a GWP of 150 or more, from 1 January 2023, except when required to meet national safety standards Technical aerosols that contain s with a GWP of 150 or more from 1 January 2018, except when required to meet national safety standards or when used for medical applications Foams Technical Aerosols Servicing and Maintenance of Refrigeration Equipment The use of fluorinated greenhouse gases with a GWP> 2500 to service or maintain refrigeration equipment with a charge size of 40 tonnes of CO 2 equivalent or more, shall be prohibited from 1 January 2020 KLEA 507 The use of fluorinated greenhouse gases with a GWP> 2500 to service or maintain military refrigeration equipment. No ban or prohibition The use of fluorinated greenhouse gases with a GWP> 2500 to service or maintain refrigeration equipment designed to cool products to temperatures below -50 C. No ban or prohibition
7 Year AC Equipment KLEA 32 Foams KLEA 32 Technical Aerosols Servicing and Maintenance of Refrigeration Equipment KLEA 23 KLEA 508
8 This guide outlines Mexichem Fluor s understanding of the F-Gas regulation at the time of going to press, it is not a definitive statement of how the regulations will be implemented. As there is the possibility of a number of implementing and delegated acts the information contained in this guide maybe subject to change. Information contained in this publication or is otherwise supplied to Users is believed to be accurate and given in good faith, but it is for the User to satisfy itself of the suitability for its own particular purpose. Mexichem Fluor gives no warranty as to the fitness of the product for any particular purpose and any implied warranty or condition (statutory or otherwise) is excluded except to the extent that such exclusion is prevented by law. Mexichem Fluor accepts no liability for loss or damage (other than death or personal injury caused by defective product, if proved), resulting from reliance on this information. Freedom under Patent, Copyright and Design cannot be assumed. KLEA and Mexichem are Trademarks of Mexichem SAB de C.V. Mexichem UK Limited is registered in England No Mexichem Fluor Not to be reproduced without the consent of the copyright owner. Contact details : Stephanie Reiss Regional Sales Manager Mexichem UK Ltd France stephanie.reiss@mexichem.com Tel: Martyn Cooper Regional Sales Manager Mexichem United Kingdom martyn.cooper@mexichem.com Tel: +44 (0) Dr. Karsten Schwennesen Sales Manager Mexichem UK Ltd Germany Karsten.Schwennesen@mexichem.com Tel: Fax: Stuart Corr Research Fellow Mexichem United Kingdom stuart.corr@mexichem.com Tel: +44 (0) Fax: +44 (0) KLEA is a registered trademark of Mexichem Fluor. Mexichem UK Limited, The Heath Business & Technical Park, Runcorn, Cheshire, WA7 4QX Tel: +44 (0) info@mexichem.com Disclaimer Information contained in this publication, or as otherwise supplied to the Users is believed to be accurate and given in good faith, but it is for the User to satisfy itself of the suitability for its own particular purpose. Mexichem Fluor gives no warranty as to the fitness of the Product for any particular purpose and any implied warranty or condition (statutory or otherwise) is excluded except to the extent that such exclusion is prevented by law. Mexichem Fluor accepts no liability for loss or damage (other than that arising from death or personal injury caused by defective product, if proved), resulting from reliance on this information. Freedom under Patent, Copyright and Design cannot be assumed. KLEA and Mexichem are trademarks of Mexichem SAB de C.V. Mexichem Fluor All rights reserved. Not to be reproduced without the consent of the copyright owner.
New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation
REI Guide 4a The 2014 EU F-Gas Regulation REI Guide 4a: F-Gas Regulation Guidance Chapters 1. Introduction... 3 2. Summary of Key Features of the new F-Gas Regulation... 4 3. Phase Down of HFC Supply...
More informationStakeholder Meeting Dublin, Ireland Update on the new F-Gas Rules Andrea Voigt, EPEE
Stakeholder Meeting Dublin, Ireland 13-06-2014 Update on the new F-Gas Rules Andrea Voigt, EPEE EPEE: the voice of the heating, cooling and refrigeration industry in Europe 1. Small medium large size entreprises
More informationLegislation & Standards
REAL Alternatives Module 6 Legislation & Standards for Alternative Refrigerants 1 Legislation & Standards For Alternative Refrigerants Contents 1 General Standards and Regulations 2 Fluorinated Gases 3
More informationNatural refrigerant trends in EU, Japan & North America
Natural refrigerant trends in EU, Japan & North America Paris, 17 July 2014 Klara Skacanova, senior analyst shecco Agenda Policy action & market for natural refrigerants: EU Japan North America Europe:
More informationSustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn
Sustainable Refrigerant Solutions for HVAC-R Laurent Abbas, Wissam Rached, Brett Van Horn 2014 ASHRAE Annual Conference Seattle, WA July 1, 2014 Learning Objectives 1. Design refrigeration and air-conditioning
More informationRefrigerants & Cooling in renovation buildings
Refrigerants & Cooling in renovation buildings 01 Basics Refrigeration circuit. 1 Refrigeration Basics LP HP Mollier Diagram A-C Evaporation B-C Superheat C-D Compression D-E Desuperheat D-G Condensation
More informationLow GWP alternative refrigerants to R404A
HUAYI Statement: Low GWP alternative refrigerants to R404A Live the cooling experience The Company: HUAYI COMPRESSOR BARCELONA (HCB) The HCB of today started out with Spanish and French capital in 1962,
More informationGuidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry
Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases BFPSA Guidance for the Fire Protection Industry 1 of 9 Contents 1. Introduction...3 2. Background...3 3. Definitions (Article
More informationOfficial Journal of the European Union. (Non-legislative acts) REGULATIONS
L 146/1 II (Non-legislative acts) REGULATIONS COMMISSION IMPLEMENTING REGULATION (EU) 2016/879 of 2 June 2016 establishing, pursuant to Regulation (EU) No 517/2014 of the European Parliament and of the
More informationInformation Guide Maintenance and Refrigerant Regulations. Issue 35
Information Guide Maintenance and Refrigerant Regulations Issue 35 Guide to Maintenance and Refrigerant regulations This is an independent guide produced by Mitsubishi Electric to enhance the knowledge
More informationEC Regulation No 842/2006 on certain fluorinated greenhouse gases
www.defra.gov.uk EC Regulation No 842/2006 on certain fluorinated greenhouse gases Supplementary Guidance for Stationary Refrigeration Airconditioning and Heat Pump Users February 2007 Department for Environment,
More informationRetrofitting Existing Systems
REAL Alternatives Module 5 Retrofitting Existing Systems 1 Retrofitting Existing Systems with low GWP Alternative Refrigerants Contents 1 F Gas Phase Down 2 Conversion 3 Available Refrigerants REAL Alternatives
More informationRefrigerant & Energy Regulations Update
Refrigerant & Energy Regulations Update Focus on Refrigeration Applications Rajan Rajendran Emerson Climate Technologies Agenda A Quick History on Refrigerant Progression Environmental Protection Agency
More informationPREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17
PREPARE FOR CHANGE LOW GWP ALTERNATIVES November 17 F-GAS PHASE DOWN Where we are now F-Gas regulation places restrictions on the use of some HFC refrigerants of high GWP. This is indirectly achieved by
More informationStay in business: STOP installing R-404A / R-507A! R-404A R-507A
Stay in business: R-507A R-404A STOP installing R-404A / R-507A! WHY IS IT URGENT TO ACT? The massive HFC phase-down step in 2018 and the Global Warming Potential (GWP) limit of 2500 in 2020 do not leave
More informationDOE and EPA Impacts to Commercial Refrigeration
DOE and EPA Impacts to Commercial Refrigeration E360 Forum Chicago, IL October 5, 2017 Ani Jayanth Director, Product Marketing Emerson Disclaimer This presentation is intended to highlight changing developments
More informationInternational New Technology and Refrigerant Symposium
International New Technology and Refrigerant Symposium Mrs Andrea Voigt, Director General The European Partnership for Energy and the Environment (EPEE) Seoul Korea, 8 March 2017 Who is EPEE? The full
More informationNew Refrigerants & Selecting Capital Equipment
F-GAS Refrigerants & Selecting Capital Equipment AN I N T E R N A T I O N A L R E F R I G E R A T I O N G R O U P Refrigerants for Capital Equipment Selections Fluorinated gases (F-gases) are a family
More informationFlammability and the Low GWP Refrigerant Challenge
Flammability and the Low GWP Refrigerant Challenge A Presentation to the BSRA Presentation On Guy Fawkes Night 5 th November 2015 Presented by Dewi Garcia MSc, MInstR Technical Manager Harp International
More informationOfficial Journal of the European Union
L 194/4 COMMISSION IMPLEMTING REGULATION (EU) 2017/1375 of 25 July 2017 amending Implementing Regulation (EU) No 1191/2014 determining the format and means for submitting the report referred to in Article
More informationSOLSTICE L40X (R-455A)
Marta San Román October, 2016 SOLSTICE L40X (R-455A) F-gas ready GWP10million
More informationEffectively Managing the Transition to Lower GWP Refrigerants
Effectively Managing the Transition to Lower GWP Refrigerants Karim Amrane, Ph.D. Senior Vice President Air-Conditioning, Heating, and Refrigeration Institute 12 th IEA Heat Pump Conference 2017 May 15-18,
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationGuidance for Stationary Refrigeration & Air-Conditioning
Information Sheet RAC 2 - Usage Guidance for Stationary Refrigeration & Air-Conditioning This Information Sheet provides background information about the use of stationary refrigeration, airconditioning
More informationEmbraco Position Paper: Light Commercial Refrigeration
Embraco Position Paper: Light Commercial Refrigeration Refrigerants Outlook 2018 www.embraco.com Introduction The global community, with Kigali Amendment to Montreal Protocol, made another important step
More informationGuided Learning Hours (GLH) 4 Invigilated Assessment (IA) 1 Total Qualification Time (5)
Qualification: Date Completed: 31 Jan 17 Unit: FIA AO Level 2 Environmental for Field Service Technicians Development Group: FD&A Development Group Guided Learning Hours (GLH) 4 Invigilated Assessment
More informationFluorinated Greenhouse Gases Use in analytical, biological and laboratory technologies
Fédération Européenne European Europäische e u r o m de l'industrie Federation of Industriede l'optique Precision vereinigung et de la Mécanique Mechanical and Feinmechanik de Précision Optical Industries
More informationGeneral Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:
Information Sheet GEN 5 Refrigerant Quantity General Guidance 1. How much refrigerant is in the system? If you have established that you are using an HFC refrigerant in a refrigeration system, the next
More informationOverview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol
Reunión de las Redes de Funcionarios de Ozono de México, Centro América, Sur América y el Caribe de habla hispana Quito, Ecuador, agosto de 2014 Overview of Alternatives and Climate Impact Scenarios Report
More informationNATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth
NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS Bernard Thonon Greth bernard.thonon@greth.fr Artificial or Natural Refrigerants? Performances COP Capacity Cost Safety Pressure, Temperature
More informationCriteria of the German Ecolabel ("Blue Angel") for Stationary Air Conditioners
For our Environment Criteria of the German Ecolabel ("Blue Angel") for Stationary Air Conditioners ATMOSphere Europe Policy & Standards Panel Dr. Daniel de Graaf, German Environment Agency (UBA) Berlin,
More informationSmart Rules - Smart Application. Introduction to Ecodesign & Energy Labelling
Smart Rules - Smart Application Introduction to Ecodesign & Energy Labelling Ecodesign Directive 2009/125/EC Evaluation resulted in no changes to the Directive Work Plan Study 2015-2017 Work Plan available
More informationBe sustainable while protecting your business
Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair
More information4: Leakage matters: for service and maintenance contractors
Guidance, Tools and Training for Refrigerant Containment Refrigerant Emissions and Leakage Skills GN 4 for 2015 Europe Leakage matters: for service and maintenance contractors REAL Zero builds on the F
More informationMeeting the Challenges of the EU HFC Phase-Down
EPEE Meeting the Challenges of the EU HFC Phase-Down EPEE Gapometer Project Key Messages November 2017 Background The EU F-Gas Regulation creates massive cuts in the CO 2 equivalent amount of HFC refrigerants
More informationFREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL
FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL www.ebacusa.com Page 1 of 13 UNPACKING Thank you for deciding to purchase an Ebac dehumidifier. Like the many tens of thousands of people who have already
More informationPossibilities of the RAC sector transformation a technical perspective
A Sustainable transformation of the Refrigeration and Air-conditioning sector Possibilities of the RAC sector transformation a technical perspective The Delegation of the European Union in India and GIZ
More informationREFRIGERANT PROCEDURE
REFRIGERANT PROCEDURE 1. PURPOSE Chlorofluorocarbons contained in some refrigerants are considered to be ozone depleting compounds and therefore damaging to the environment. The Environmental Protection
More informationHyperion 1000 Greenhouse LED Grow Light Product Datasheet
Hyperion 1000 Greenhouse LED Grow Light Product Datasheet Key Features 1000 micromoles/s light output. Equivalent to 600w sodium grow lights 40% energy saving versus sodium Up to 2.8 µmol/joule efficiency
More informationRecord of Amendments. Version Date Amendment Section/page affected
Industry support for effective compliance BTHA Guidance on The Restriction Of The Use Of Certain Hazardous Substances In Electrical and Electronic Equipment (recast) (RoHS) Directive 2011/65/EU Comparison
More informationRequirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)
Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC) 1. Introduction 18 October 2006 The use of Chlorofluorocarbons (CFCs)
More informationworld natural refrigerants trends market availability, technology trends & the impact of policy
world natural refrigerants trends market availability, technology trends & the impact of policy San Francisco, June 18, 2014 Nina Masson, Deputy Managing Director shecco natural refrigerants world trends
More informationRecommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS
COMMERCIAL REFRIGERATION RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS www.tecumseh.com Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) 1-HCFCs & HFCs Retrofit
More informationWorldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition
Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL Second Edition STAR DISTRIBUTION CENTRES WORLDWIDE Argentina (to be opened shortly) Australia Bahrain Belgium Brazil
More informationnatural refrigerants - global trends & developments
natural refrigerants - global trends & developments February 3, 2014 Nina Masson, Head of Market Research shecco Japan a wide range of applications for natural refrigerants a wide range of applications
More informationUnderstanding Applications for Alternative Refrigerants
Understanding Applications for Alternative Refrigerants E360 Forum Chicago, IL October 5, 2017 Jason Prenger Director of Engineering Emerson Disclaimer This presentation is intended to highlight changing
More informationDUH Background Paper. Deficiencies in treatment of CFC-containing waste refrigeration equipment in Germany
DUH Background Paper Deficiencies in treatment of CFC-containing waste refrigeration equipment in Germany (7 November 2007) I. Current situation The German Waste Electrical and Electronic Equipment Act
More informationUnder-floor heating system The technology of tomorrow
Waxman heating the nation PRIMARY HEAT TM Under-floor heating system The technology of tomorrow Under tiles, carpet, wood and vinyl Under-floor heating that warms the whole home Imagine a heating system
More informationLarge AC units using a variety of low-gwp options
Large AC units using a variety of low-gwp options By : Dr Alaa Olama, consultant, Egypt. The Workshop on Management of HFCs: Technical Issues Bangkok, Thailand, 20 and 21 April 2015. Alternatives to currently
More informationLocal air conditioner
Instruction Manual Local air conditioner LAC08C16 Contents Safety Warnings...4 Unpacking...7 Product Overview...8 Front View...8 Rear View...8 Control Panel...9 Remote Control... 10 Moving the Unit...10
More information(Text with EEA relevance)
L 301/14 18.11.2015 COMMISSION IMPLEMTING REGULATION (EU) 2015/2065 of 17 November 2015 establishing, pursuant to Regulation (EU) No 517/2014 of the European Parliament and of the Council, the format for
More informationRefrigerant and Energy Regulations Update
Refrigerant and Energy Regulations Update Focus on Refrigeration Applications Dr. Rajan Rajendran Emerson Climate Technologies HFC Phase-Down Amendment to Montreal Protocol Closer to Reality North America
More informationOfficial Journal of the European Union
8.7.2015 L 177/19 COMMISSION REGULATION (EU) 2015/1095 of 5 May 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for professional
More informationBRA FACT FINDER Number 19
BRA FACT FINDER Number 19 Issue: 1 Date: March 2017 A practical guide to using refrigerants with a temperature glide This document is the second in a series of bulletins produced by the BRA following the
More informationWöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13
Carbon Monoxide Meter Contents 1. Important information... 12 2. Specification... 13 3. Operating Elements... 14 4. Operation Instructions... 15 5. 0-ppm-Calibration... 16 6. Troubleshooting... 17 7. CO
More informationCOMMISSION REGULATION (EU) No /.. of XXX
EUROPEAN COMMISSION Brussels, XXX [ ](2013) XXX draft COMMISSION REGULATION (EU) No /.. of XXX implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign
More informationNew Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA
New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA 5 th March 2014 Honeywell $39-39.5B in sales* 54% sales outside U.S. 1,300 sites, 70 countries 132,000 employees Morristown,
More informationThis FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094.
This FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094. They are not intended to replace the regulations nor to provide
More informationInformation for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.
Information for practitioners 5 selection guidelines. An overview of the refrigerants of the future. Helping you choose the right refrigerant. You can rely on our expertise Selecting the right refrigerant
More informationThe products covered by the Regulation can be classified as follows:
Table of Contents 1. Purpose of the guidelines and disclaimer... 3 1.1. The Regulation... 3 2. Scope... 3 3. Product environmental impacts... 4 4. State of play of legislation... 4 4.1. History of the
More informationDaikin s Policy. and Comprehensive Actions on the Environmental Impact of
Daikin s Policy and Comprehensive Actions on the Environmental Impact of Refrigerants Daikin provides homes, businesses and industries worldwide with cooling, heating and refrigeration solutions. We also
More informationISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials
INTERNATIONAL STANDARD ISO 3452-2 First edition 2000-04-01 Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials Essais non destructifs Examen par ressuage Partie 2: Essais des
More informationCOMMISSION REGULATION (EU) No /.. of
EUROPEAN COMMISSION Brussels, 30.11.2016 C(2016) 7769 final COMMISSION REGULATION (EU) No /.. of 30.11.2016 implementing Directive 2009/125/EC of the European Parliament and of the Council establishing
More informationSolkane High Performance Refrigerants
Solkane High Performance Refrigerants Solvay Fluor Solkane Refrigerants our knowledge on CD-ROM Technical Data Program Calculate all important thermophysical properties of Solkane Refrigerants Customise
More informationConstruction Products Regulation (CPR) and cables. British Cables Association Guidance to Specifiers
Construction Products Regulation (CPR) and cables British Cables Association Guidance to Specifiers 1 Outline In January 2017 BCA issued its Guidance to Specifiers. A key consideration at the time was
More informationEffectively Managing the Transition to Lower GWP Refrigerants
Effectively Managing the Transition to Lower GWP Refrigerants Karim Amrane a, * a Air-Conditioning, Heating, and Refrigeration Institute, 2111 Wilson Blvd. Suite 500, Arlington, VA, USA Abstract Environmental
More informationBUSINESS PLAN CEN/TC 132 ALUMINUM AND ALUMINIUM ALLOYS EXECUTIVE SUMMARY
Page: 1 BUSINESS PLAN CEN/TC 132 ALUMINUM AND ALUMINIUM ALLOYS EXECUTIVE SUMMARY 1. BUSINESS ENVIRONMENT OF THE CEN/TC 132 It may be hard to believe but only 150 years ago aluminium was considered to be
More informationImportant Safety Notice
Date: 27 th April 2015 Page 1 of 12 SPI Lasers UK Limited Safety Information High Power OEM Fibre Lasers Important Safety Notice This notice outlines important safety related information and must be read
More informationRequirements for Labelling: Labelling of Refrigerant Containers
DRAFT GRENADA NATIONAL STANDARD Requirements for Labelling: Labelling of Refrigerant Containers Copyright GDBS 2016 This is a draft standard for Public Comments only. No part of this draft may be reproduced
More informationCOMMISSION REGULATION (EU) No /.. of XXX
EUROPEAN COMMISSION Brussels, XXX [ ](2014) XXX draft COMMISSION REGULATION (EU) No /.. of XXX implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign
More informationUser s Operation Instructions & Important Warranty Information
United Kingdom en User s Operation Instructions & Important Warranty Information High-efficiency wall-hung boilers Baxi Avanta Plus 18s - 24s - 30s 24c - 28c - 35c - 39c Please keep these instructions
More informationyour comfort. our world. Altherma Flex Type Renewable heat pump system for every environment
your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment Outdoor One or more indoor or outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma
More informationOPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB
OPERATION MANUAL System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB CONTENTS Read before operation Part name and functions...2 Safety precautions...2
More informationUnderstanding Applications for Alternative Refrigerants
Understanding Applications for Alternative Refrigerants E360 Forum Raleigh, N.C. March 1, 2017 Todd DeVore Director Technical Support Services Emerson Disclaimer This presentation is intended to highlight
More informationFact File 78. Portable Fire Extinguishers under the ADR. Note: This Fact File supersedes Fact File 060 which is withdrawn
Fact File 78 Portable Fire Extinguishers under the ADR Note: This Fact File supersedes Fact File 060 which is withdrawn The European Agreement concerning the International Carriage of Dangerous Goods by
More informationEVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES
EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES Ola, Gustafsson M.Sc. a *, Lennart Rolfsman M.Sc. a, Sara Jensen B.Sc. a, Markus Lindahl M.Sc. a, a SP Technical
More informationTITLE: Ice-lined Refrigerator or Combined Refrigerator-Icepack Freezer, Compression Specification reference:
Version: Draft Effective date: Page: 1 of 6 PQS performance specification WHO/XXX Original: English Distribution: General TITLE: Ice-lined Refrigerator or Combined Refrigerator-Icepack Freezer, Compression
More informationISO 7439 INTERNATIONAL STANDARD. Copper-bearing intra-uterine contraceptive devices Requirements, tests
INTERNATIONAL STANDARD ISO 7439 Second edition 2002-03-15 Copper-bearing intra-uterine contraceptive devices Requirements, tests Dispositifs intra-utérins contenant du cuivre Spécifications, essais Reference
More informationJBCE input for the RoHS FAQ document
JBCE input for the RoHS FAQ document JBCE welcomes the recast of the RoHS Directive 2011/65/EU (hereafter generally referred to as RoHS 2 ) 1 and appreciates the ongoing work by the Commission in realizing
More information1 Status China ratified the Montreal Protocol and the London amendment on June 14, It is an Article 5 country.
(Information provided in August 2000) 2 1 Status ratified the Montreal Protocol and the London amendment on June 14, 1991. It is an Article 5 country. 2 ODS Focal Point The State Environmental Protection
More informationOM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.
MADE IN Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info OM-CP-Cryo-Temp Ultra Low Temperature Data Logger OM-CP-Cryo-Temp Product Notes Manual Start When the
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-21896-6 Edition 1 SOUTH AFRICAN NATIONAL STANDARD Medical gas pipeline systems Part 1: Pipeline systems for compressed medical gases and vacuum This national standard is a modified adoption
More informationR-404A Alternative with Low Compressor Discharge Temperature
2175, Page 1 R-404A Alternative with Low Compressor Discharge Temperature Barbara MINOR 1 *, Vladimir SULC 2, Jeff BERGE 3, Michal KOLDA 4, Michal HEGAR 5 1 DuPont, Fluoroproducts, Wilmington, DE, USA
More informationExhibition Hall 1. Fachprogramm. Technical Programme
Exhibition Hall 1 Fachprogramm Technical Programme Nuremberg (Germany), 15 th October, 2014 Page 1 Ammonia and Natural Refrigerants in Turkey Hüseyin M. Yüksel ISKID-AC&R Manufacturers Association, Turkey
More informationLegal Framework Conditions for the Use of Natural Refrigerants in Switzerland
eurammon Symposium 2017 Legal Framework Conditions for the Use of Natural Refrigerants in Switzerland Dr. Henry Wöhrnschimmel, FOEN Schaffhausen, 22 nd /23 rd June, 2017 Current legal bases in Switzerland
More informationAS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009
AS/NZS 4474.2:2009 (Incorporating Amendment Nos 1 and 2) Australian/New Zealand Standard Performance of household electrical appliances Refrigerating appliances Part 2: Energy labelling and minimum energy
More informationRole of CE Marking in the Placing on the Market of Electronic Components
Explanatory Leaflet Role of CE Marking in the Placing on the Market of Electronic Components New Legislative Framework Component Industries RoHs Directive CE Marking Low Voltage Directive Electronic Components
More information3M Novec Fire Protection Fluid
1 3M Novec Fire Protection Fluid Frequently Asked Questions (FAQs) Smart performance FAQs Q What is 3M Novec 1230 Fire Protection Fluid? A Novec 1230 fluid is a sustainable fire extinguishing clean agent
More informationRefrigerant and Energy Regulations Update
Refrigerant and Energy Regulations Update Focus on Refrigeration Applications Dr. Rajan Rajendran Emerson Climate Technologies Reference and Disclaimer Reference: Federal Register Vol. 80 No. 138, July
More informationGeneral safety precautions English
English 1 1 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow
More informationGo Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over
Danfoss Solutions for Cold Rooms Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading
More information3M Benchtop Air Ionizer 963E. User s Guide
3M Benchtop Air Ionizer 963E User s Guide 1 Table of Contents Section Page Safety Information...3 1. Description...4 2. Performance...4 3. Power Requirements...4 4. Installation...4 5. Operation...5 6.
More informationG-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors
G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors EN Operating Manual 2 3 Contents Safety and Warning information 2 Introduction 3 Operation & Set Up 3 Cellaguard Features 3 Initial Set Up 4
More informationGo Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over
Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading
More informationCOMMISSION REGULATION (EU) / of XXX
EUROPEAN COMMISSION Brussels, XXX [ ](2018) XXX draft COMMISSION REGULATION (EU) / of XXX laying down ecodesign requirements for refrigerating appliances with a direct sales function pursuant to Directive
More informationInstallation and Servicing Instructions
Installation and Servicing Instructions Zenex GasSaver GS-1 Passive Flue Gas Heat Recovery Device (PFGHRD) Recognised by the Government s Standard Assessment Procedure (SAP) IMPORTANT: Read these instructions
More informationQ. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:
Basic Facts About Hydrocarbons Q. What are hydrocarbons? Hydrocarbon refrigerants are environmentally friendly, non-toxic, non-ozone-depleting replacement for chlorofluorocarbons (CFCs), hydrochlorofluorocarbons
More informationNavigating a changing refrigerants market
White paper Navigating a changing refrigerants market A guide for selecting and accommodating alternative refrigerants for diverse heating and cooling applications January 2018 Contents 1. Introduction...3
More informationUsing consumer appliances in Europe the consumer view
Using consumer appliances in Europe the consumer view February 2011 European Association for the Co-ordination of Consumer Representation in Standardisation Av. de Tervueren 32, box 27 B-1040 Brussels,
More information