1 en Pump PS PS PSA OPERATOR S MANUAL E N

2

3 Foreword Foreword This manual provides information and procedures to safely operate and maintain this Wacker Neuson model. For your own safety and protection from injury, carefully read, understand and observe the safety instructions described in this manual. Keep this manual or a copy of it with the machine. If you lose this manual or need an additional copy, please contact Wacker Neuson Corporation. This machine is built with user safety in mind; however, it can present hazards if improperly operated and serviced. Follow operating instructions carefully! If you have questions about operating or servicing this equipment, please contact Wacker Neuson Corporation. The information contained in this manual was based on machines in production at the time of publication. Wacker Neuson Corporation reserves the right to change any portion of this information without notice. All rights, especially copying and distribution rights, are reserved. Copyright 2008 by Wacker Neuson Corporation. No part of this publication may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission from Wacker Neuson Corporation. Any type of reproduction or distribution not authorized by Wacker Neuson Corporation represents an infringement of valid copyrights and will be prosecuted. We expressly reserve the right to make technical modifications, even without due notice, which aim at improving our machines or their safety standards. wc_tx000001gb electric.fm 3

4 Foreword wc_tx000001gb electric.fm 4

5 PS / PS / PSA Table of Contents Foreword 3 1. Safety Information Operating and Electrical Safety Information Labels Operation Names of Parts Prior to Operation Installation Electrical Wiring Electrical Circuit Diagrams Operation Maintenance Periodic Maintenance Table Maintenance and Inspection Disassembly/Reassembly Disassembly Reassembly Troubleshooting Technical Data Standard Specifications Operating Specifications (60 Hz) Dimensions wc_bo en_003toc.fm 5

6 Safety Information PS / PS / PSA Safety Information This manual contains DANGER, WARNING, CAUTION, NOTICE and NOTE callouts which must be followed to reduce the possibility of personal injury, damage to the equipment, or improper service. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE: Used without the safety alert symbol, NOTICE indicates a situation which, if not avoided, could result in property damage. Note: Contains additional information important to a procedure. wc_si000035gb.fm 6

7 PS / PS / PSA Operating and Electrical Safety Safety Information WARNING To reduce risk of electric shock, connect only to a properly grounded, grounding-type receptacle. Risk of electric shock this pump has not been investigated for use in swimming pool areas. An acceptable motor-control switch shall be provided at the time of installation according to local codes and regulations. To reduce risk of electric shock, follow instructions in this manual for proper installation. CAUTION: This pump may automatically restart. Prior to working on the pump or control panel, all supply circuits must be disconnected. CAUTION: Risk of shock do not remove cord and strain relief. 1.2 Information Labels Label Wacker Neuson Corporation Menomonee Falls, WI USA Model Item No. Rev. Serial No. Man.Y/M THERMALLY PROTECTED INDOORS OR OUTDOORS CSA ENCLOSURE 3 V Hz Phase Amp. Conforms to UL Std. 778 Cert. to CAN/CSA Std. C22.2 No. 108-M89 Max. m Max. L/min kg kw Max. ft Max. GPM lbs HP C US L I STED MADE IN TAIWAN R Meaning A nameplate listing the model number, item number, revision number, and serial number is attached to each unit. Please record the information found on this plate so it will be available should the nameplate become lost or damaged. When ordering parts or requesting service information, you will always be asked to specify the model number, item number, revision number, and serial number of the unit. wc_si000035gb.fm 7

8 Operation PS / PS / PSA Operation 2.1 Names of Parts See Graphic: wc_gr wc_gr Ref. Description Ref. Description 1. Lifting Handle 8. Seal-mechanical 2. Coupling 9. Lubricant 3. Oil Lifter 10. Seal-dust 4. Oil Plug 11. Sleeve 5. Cover-suction 12. Housing-oil 6. Strainer 13. Wear Ring 7. Cable Assembly 14. Impeller wc_tx000113gb.fm 8

9 PS / PS / PSA Prior to Operation Operation CAUTION 2.3 Installation When the pump is delivered, first perform the following checks: Inspection While unpacking, inspect the product for damage during shipment, and make sure all bolts and nuts are tightened properly. Specification check Check the model number to make sure it is the product that was ordered. Be certain it is the correct voltage and frequency. Note: If there is any problem with the product as shipped, contact your nearest dealer or Wacker Neuson representative at once. Product specifications Do not operate this product under any conditions other than those for which it is specified. Failure to observe this precaution can lead to electrical shock, current leakage, fire, water leakage or other problems. WARNING If the pump is used to drain a swimming pool, the pump must be connected to a Ground Fault Interrupter (GFI). If the pump is used in fountains, the pump must be connected to a Ground Fault Interrupter (GFI). The pump must not be used when people are in the water. Leakage of pump lubricants may cause pollution of water. Proper plug must be provided according to local codes and standards. Refer to wiring diagram. DO NOT use this pump in liquids other than water, such as oil, salt water, or organic solvents. Use with a power supply voltage within ±5% of the rated voltage. DO NOT use in water temperatures outside the range of F (0 40 C) which can lead to failure, current leakage or shock. DO NOT use in the vicinity of explosive or flammable materials. Use only in fully assembled state. Note: Consult your local dealer or Wacker representative before using with any liquids other than those indicated in this document. Preparing for installation Before installing the pump at a work site, you will need to have the following tools and instruments ready: wc_tx000113gb.fm 9

10 Operation PS / PS / PSA Insulation resistance tester (megohmmeter) AC voltmeter AC ammeter (clamp-on type) Bolt and nut tighteners Power supply connection tools (screwdriver or box wrench) Note: Please also read the instructions that come with each of the test instruments. Checks to Make Before Installation When a three-prong grounded plug is used: Use the megohmmeter to measure the motor insulation resistance between the grounding prong and each one of the two power prongs. When connection wires are used: With the megohmmeter, measure the insulation resistance between the ground wire (Green) and each one of the two power wires. Reference insulation resistance: 20MΩ or greater. Note: The reference insulation resistance (20MΩ or greater) is the value when the pump is new or has been repaired. For the reference value after installation, see Maintenance and Inspection. DO NOT measure the insulation resistance with insulation resistance tester for the following parts. It will cause damage (Model PSA 2 500). CAUTION See Graphic: wc_gr Improper ways to measure insulation resistance 1. Between the plug prongs. 2. Between the electrodes on the level relay unit. 3. Between the electrodes on the level relay unit and the plug prongs. Precautions in Installation WARNING wc_tx000113gb.fm 10 wc_gr000258

11 PS / PS / PSA Operation When installing the pump, pay close attention to its center of gravity and weight. If it is not lowered into place correctly, it may fall and be damaged or cause injury. When transporting the machine by hand, be sure to employ manpower commensurate with the weight of the machine. To avoid back injury when lifting the machine, bend the knees to pick it up rather than bending your back only. Do not under any circumstances install or move the pump by suspending it from the cable assembly. The cable may be damaged, CAUTION causing current leakage, shock, or fire Avoid dropping the pump or other strong impact. Lift the pump by holding it firmly with the hands or by attaching a rope or chain to the lifting handle. Note: On cable assembly handling, see Electrical Wiring. Avoid dry operation, which will not only lower performance but can cause the pump to malfunction, leading to electrical leakage and shock. CAUTION Install the pump in a location with sufficient water level, where water collects readily. Note: See Operation ( Operating Water Level ) for the water level necessary for operation. Note: The discharge end of the hose should be located higher than the water surface. If the end of the hose is submerged, water may flow back to the pump when the pump is stopped; and if the hose end is lower than the water surface, water may overflow when the pump is turned off. If large quantities of earth are sucked up, damage resulting from friction in the pump can lead to current leakage and shock. CAUTION Use the pump in the upright position. To prevent the strainer from becoming submerged in mud, causing it to suck in sand or debris, mount it on a block or other firm base If used in a permanent installation where the pump is not readily accessible after installation, please contact Wacker Neuson for a duplicate nameplate to be installed at the wellhead or on the control box so that it will be readily visible. CAUTION DO NOT lift or hang the pump by the level relay unit (1). It will lead to damage and may cause leakage, electric shock, and fire (Model PSA 2 500). See Graphic: wc_gr wc_tx000113gb.fm 11

12 Operation PS / PS / PSA wc_gr Electrical Wiring WARNING Performing electrical wiring Electrical wiring should be performed by a qualified person in accord with all applicable regulations. Failure to observe this precaution not only risks breaking the law but is extremely dangerous. Incorrect wiring can lead to current leakage, electrical shock or fire. ALWAYS make sure the pump is equipped with the specified overload protectors and fuses or breakers, so as to prevent electrical shock from a current leak or pump malfunction. Operate within the capacity of the power supply and wiring. WARNING CAUTION WARNING CAUTION Grounding DO NOT use the pump without first grounding it properly. Failure to ground it can lead to electrical shock from a current leak or pump malfunction. DO NOT attach the grounding wire to a gas pipe, water pipe, lightning arrester or telephone grounding wire. Improper grounding can result in electrical shock. Connecting the power supply Before connecting wires to the terminal, make certain the power supply is turned off (circuit breaker, etc.), to avoid electrical shock, shorting, or unexpected starting of the pump, leading to injury. Before inserting the power supply plug, make certain the power supply is turned off (circuit breaker, etc.), to avoid electrical shock, shorting, or unexpected starting of the pump, leading to injury. Do not use the pump with the cable assembly or plug connected loosely, which can result in electric shock, shorting, or fire. wc_tx000113gb.fm 12

13 PS / PS / PSA Operation Draw power from a dedicated power outlet rated at 15 A or above. Sharing the outlet with other equipment may cause overheating at the branch outlet and could result in fire. The three-prong grounded plug shall be connected as shown in the drawing. NOTICE: Be sure to use a dedicated power supply with a ground leakage circuit breaker. Note: The shape of the plug may differ from that shown in the illustration. See Graphic: wc_gr and wc_gr W R G wc_gr CAUTION Cable Assembly If it is necessary to extend the cable assembly, use a core size equal to or larger than the original. This is necessary not only to avoid a performance drop, but to prevent cable overheating which can result in fire, electrical leakage or electrical shock. If a cable with cut insulation or other damage is submerged in the water, there is a danger of damage to the pump, electrical leakage, electrical shock, or fire. Be careful not to let the cable assembly be cut or become twisted. This may result in damage to the pump, electrical leakage, electrical shock, or fire. If it is necessary to submerge the connection wires of the cable assembly in water, first seal the wires completely in a molded protective sleeve, to prevent electrical leakage, electrical shock, or fire. DO NOT allow the cable assembly wires or power supply plug to become wet. Make sure the cable does not become excessively bent or twisted, and does not rub against a structure in a way that might damage it. If used in a deep-well installation, the cable assembly should be secured every twenty feet. wc_tx000113gb.fm 13

14 Operation PS / PS / PSA Electrical Circuit Diagrams See Graphics: wc_gr001201, wc_gr001202, and wc_gr R R 1 W W 5 2 B L 3 G G/Y 6 4 wc_gr PS POWER SOURCE SINGLE PHASE Ref. Description Ref. Description 1 Capacitor 6 Ground 2 Main coil 7 Circle thermal protector 3 Auxiliary coil 8 Float switch (normally open contact) 4 Miniature protector 9 Heater 5 Frame grounding Wire Colors B Black V Violet Or Orange G Green W White Pr Purple L Blue Y Yellow Sh Shield P Pink Br Brown LL Light Blue R Red Cl Clear G/Y Green/Yellow T Tan Gr Gray wc_tx000113gb.fm 14

15 PS / PS / PSA Operation 1 R B 2 3 R 4 W W 9 W W 5 6 B L 7 10 G G/Y 8 wc_gr PSA POWER SOURCE SINGLE PHASE Ref. Description Ref. Description 1. Level Relay Unit 6. Main Coil 2. Transformer 7. Auxiliary Coil 3. Electrode 8. Miniature Protector 4. Capacitor 9. Frame Grounding 5. Triac 10. Ground Wire Colors B Black V Violet Or Orange G Green W White Pr Purple L Blue Y Yellow Sh Shield P Pink Br Brown LL Light Blue R Red Cl Clear G/Y Green/Yellow T Tan Gr Gray wc_tx000113gb.fm 15

16 Operation PS / PS / PSA R R R R 2 W W G G L L 8 PS POWER SOURCE SINGLE PHASE 6 wc_gr Ref. Description Ref. Description 1. Circle Thermal Protector 5. Centrifugal Switch 2. Auxiliary Coil 6. Capacitor 3. Heater 7. Frame Grounding 4. Main Coil 8. Ground Wire Colors B Black V Violet Or Orange G Green W White Pr Purple L Blue Y Yellow Sh Shield P Pink Br Brown LL Light Blue R Red Cl Clear G/Y Green/Yellow T Tan Gr Gray CAUTION If connected to a circuit protected by a fuse, use a time-delay fuse with this pump. wc_tx000113gb.fm 16

17 PS / PS / PSA Operation Operation Before starting Make sure once again that the product is of the correct voltage and frequency rating. NOTICE: Using the product at other than rated voltage and frequency will not only lower its performance but may damage the product. Note: Confirm the rated voltage and frequency on the model nameplate Confirm the wiring, supply voltage, circuit breaker capacity, and motor insulation resistance. Reference insulation resistance = 20 MΩ or greater. Note: The reference insulation resistance (20 MΩ or greater) is the value when the pump is new or has been repaired. For the reference value after installation see Maintenance and Inspection The setting on the circuit breaker or other overload protector should be made in accord with the rated current of the pump. Note: See Operating Specifications for the rated current of the pump When powering the pump with a generator, be certain the generator is sized to supply the required power for the pump and any other equipment powered by the generator. WARNING WARNING Non-Automatic Models (PS 2 500, PS 2 750) Test Operation NEVER operate the pump while it is suspended in the air. The recoil may result in injury or other major accident. NEVER start the pump when people are standing next to it. A current leak can result in electrical shock. Run the pump for a short time (3 10 minutes) and confirm the following: Using an ammeter (clamp-on type), measure the operating current at the L1 and L2 phase wires on the terminal. COUNTERMEASURE: If the operating current exceeds the rated value, pump motor overload may be a cause. Make sure the pump has been installed under proper conditions as described in Installation. Using an AC voltmeter (tester), measure voltage at the terminals. Supply voltage tolerance: within ±5% of rated voltage. wc_tx000113gb.fm 17

18 Operation PS / PS / PSA CAUTION COUNTERMEASURE: If the supply voltage is outside the tolerance, possible causes are the power supply capacity or an inadequate extension cable. Look again at the wiring diagram and make sure the conditions are proper. In case of very excessive vibration, unusual noise or odor, turn off the power immediately and consult your nearest dealer or Wacker representative. Continuing to operate the pump under abnormal conditions may result in electrical shock, fire, or current leakage. WARNING Operation Make sure no extraneous objects such as pins, nails or other metal objects are sucked into the pump. These can damage the pump or cause it to malfunction, and can result in electrical shock or electrical leakage. When the pump is not used for an extended period, be sure to turn off the power (circuit breaker, etc.). Deterioration of the insulation may lead to electrical leakage, electrical shock, or fire. In case of a power outage, turn off the power to the pump to avoid having it start unexpectedly when the power is restored, presenting serious danger to people in the vicinity. CAUTION The pump may become hot during operation. Do not touch an operating pump. Allow the pump to cool before handling. Pay careful attention to the water level while the pump is operating. Dry operation may cause the pump to malfunction. Note: See section Operating water level, for the water level necessary for operation. If the protection system operates due to an overload or malfunction, causing the pump to stop, first investigate and remove the cause before restarting. CAUTION Operating water level Do not operate the pump below the C.W.L. (Continuous running Water Level) indicated below. Failure to observe this condition may result in damage to the pump, current leakage or electrical shock. wc_tx000113gb.fm 18

19 PS / PS / PSA Operation See Graphic: wc_gr a b C.W.L 115 mm (4-1/2") PS 2 500, PS PSA wc_gr Operating Water Level (PS 2 500, PS 2 750). Pump Model C.W.L. PS mm (2 ) PS mm (4 ) Operating water level (PSA only) Starting the Pump: This pump starts when water reaches the electrodes on the level relay unit, conducting current between them. Note: The necessary water level to operate the pump is 115 mm (4-½") from the bottom of the pump. To force start the pump for trial operation, short-circuit the electrodes (a) with a screwdriver (b) as illustrated. Please keep items that may clog the pump (such as wires, nails, cords, etc.) away from it. Motor Protection System (Motor Protector) Circle Thermal protector (PS 2 750) Miniature Protector (PS 2 500, PSA 2 500) The pump has a built-in motor protection system. If an excessive current is detected (PS 2 750) or the motor overheats, for reasons such as the following, the pump will automatically stop operating regardless of the water level, to protect the motor: Change in supply voltage polarity wc_tx000113gb.fm 19

20 Operation PS / PS / PSA Overload Open-phase operation or operation under constraint Note: Always determine the cause of the problem and resolve it before resuming operation. Simply repeating cycles of stopping and restarting will end up damaging the pump. Do not continue operation at very low lift, low water level, or while the strainer stand is clogged with debris. Not only will performance suffer, but also such conditions may cause noise, heavy vibration, and malfunctioning. Operating Cycle of Automatic Type (PSA 2 500). Stage Level Relay Unit Pump Water Level 1 When electrodes (b) of level relay units (a) submerge under water, the resulting electric current causes the pump to operate. (Electrodes sensing the electricity) 2 When the water level goes below the height of the electrodes, a timer is activated. The pump keeps operating. (No electric current >Timer activates.) 3 The pump keeps operating for approximately one minute. (The pump resumes the operation if the electrodes contact the water again within one minute.) 4 The pump stops one minute later. (The pump may not stop operating for a longer period of time.) 5 When the water level rises again and the electrodes touch the water, the pump starts operating again. (Electrodes sensing the electricity) See Graphic: wc_gr Operation starts (drainage) Operation remains (drainage) Operation remains (drainage) Operation stops Operation starts again (drainage) Falls Falls Falls Rises Falls wc_tx000113gb.fm 20

21 PS / PS / PSA Operation a a b 1 b wc_gr wc_tx000113gb.fm 21

22 Maintenance PS / PS / PSA Maintenance 3.1 Periodic Maintenance Table Pump Weekly Monthly Every 1000 hrs. Measure insulation resistance. Reference insulation resistance = 1MW or greater. (1) Measure operating current. Compare with rated current. Measure supply voltage. Compare with allowable range (within ±5% of rated voltage). Pump inspection. A noticeable drop in performance may indicate wear in the impeller, etc., or else clogging of the strainer, etc. Remove the clogged debris and replace any worn parts. Lubricant inspection. Change lubricant. Designated lubricant: SAE 10W/20W. (2) Change mechanical seal. (3) Overhaul. This should be carried out even if there are no problems with the pump. The frequency depends on how continuously the pump is in use. (4) Every 2000 hrs. (1) If the insulation resistance has become noticeably lower than the previous inspection, an inspection of the motor will be necessary. (2) See Lubricant Inspection and Lubricant Change in this section. (3) Specialized know-how is required for inspecting and replacing the mechanical seal. Consult with your nearest dealer or Wacker representative. (4) Consult with your nearest dealer or Wacker representative regarding overhauls. wc_tx000114gb.fm 22

23 PS / PS / PSA Maintenance and Inspection Maintenance Regular maintenance and inspections are a necessity for continued efficient functioning of the pump. If any abnormal conditions are noticed, refer to the Troubleshooting section and take corrective measures immediately. It is recommended that a spare pump be kept ready in case of any problems. Prior to inspecting Before inspecting the pump, make certain the power supply (circuit breaker, etc.) is turned off. Then, unplug the cable assembly from the receptacle or detach it from the terminals. Failure to follow this precaution may result in a serious accident from electrical shock or unexpected starting of the pump motor Washing the pump Remove accumulated matter from the surface of the pump and wash it with clean water. Take special care to remove any debris from the impeller Inspecting the pump exterior Look for any peeling or chipped paint, and make sure the nuts and bolts are fastened tightly. Any cracks in the surface should be repaired by cleaning that area, drying it and then applying a touch-up coating. Note: Touch-up paint is not supplied. Note that some kinds of damage or looseness may require that the unit be disassembled for repairs. Please consult your nearest dealer or Wacker representative. WARNING Storage When the pump is out of use for an extended period, wash it and dry it thoroughly, then store it indoors. Note: Always run a test operation before putting the pump back into service. If the pump is left in the water, it should be run a minimum of once a week. Inspecting Lubricant Remove the oil plug and tilt the pump to drain a small amount of lubricant. If the lubricant is milky white or has water mixed in with it, the mechanical seal may be faulty. In this case the pump will need to be disassembled and repaired. Replacing Lubricant Remove the oil plug and drain all the lubricant, then replace it with the specified amount. wc_tx000114gb.fm 23

24 Maintenance PS / PS / PSA Note: Worn lubricant and other waste products should be disposed of by a qualified agent, in accord with applicable laws. The oil plug gasket should be replaced each time the lubricant is inspected or changed. See Graphic: wc_gr wc_gr Ref. Description Ref. Description 1. Oil Inlet 3. Oil Plug 2. Gasket 4. Allen Wrench Pump Model PS PS 2 500, PSA PS Lubricant Capacity 160 ml (5.4 fl. oz.) 155 ml (5.2 fl. oz.) 210 ml (7.1 fl. oz.) Replacement Parts The table lists the parts that need to be replaced periodically. Replace these using the recommended frequency as a guideline. Part Mechanical seal Lubricant (SAE 10W/20W) Gasket Dust seal Sleeve Replacement Frequency When lubricant in oil compartment becomes milky. Every 2,000 hours or 12 months, whichever comes first. Each time pump is disassembled or inspected. When ring is worn, and each time pump is disassembled or inspected. When it becomes worn. wc_tx000114gb.fm 24

25 PS / PS / PSA Disassembly/Reassembly Maintenance WARNING Before disassembling the pump, make certain the power supply (circuit breaker, etc.) is turned off. Then, unplug the cable assembly from the receptacle or detach it from the terminals. To avoid electrical shock, DO NOT work with wet hands. NEVER check the operation of any parts (impeller rotation, etc.) by turning on the power while the unit is partially assembled. Failure to observe these precautions may result in a serious accident. DO NOT disassemble or repair any parts other than those designated here. If repairs are necessary in any other than the designated parts, consult your nearest dealer or Wacker representative. Improper repairs can result in electrical leakage, electrical shock, fire, or water leaks. After reassembly, ALWAYS perform a test operation before resuming use of the pump. Improper assembly will cause the pump to malfunction, resulting in electric shock or water leaks. The procedure for disassembly and reassembly is shown here to the extent necessary for impeller replacement. A specialized environment and facilities are necessary for work on the mechanical seal and the motor parts. Contact your nearest dealer or Wacker representative in the event such repairs are necessary. wc_tx000114gb.fm 25

26 Maintenance PS / PS / PSA Disassembly See Graphic: wc_gr Removing the strainer, suction cover, and volute: Remove the bolts (1) under the strainer (2), then remove the strainer, suction cover (3), and volute (4) Removing the Impeller: With a box wrench or other tool, remove the acorn nut (6), lockwasher (7) and washer (8), then remove the impeller (9), sleeve (10) and dust seal (11) from the shaft Removing the wear ring: Remove the wear ring (12) from the volute. A worn impeller may have sharp edges that can cause injury, and should be handled with care. WARNING Note: The exploded view shown is for model PS Other models may differ slightly in shape and structure wc_gr wc_tx000114gb.fm 26

27 PS / PS / PSA Reassembly See Graphic: wc_gr001206, wc_gr Maintenance Mount the dust seal (11) onto the outside of the sleeve (10) as shown in the drawing. When doing so, do not apply oil or other lubrication to the surface where the dust seal contacts the sleeve (a) When replacing the wear ring (12), make sure the front and back are oriented correctly. The side with the protrusions around the edge should face the volute (4). Press the wear ring firmly onto the surface Replace the dust seal and sleeve as one piece Align the impeller keyway with the rotor shaft keyway and push the impeller (9) onto the rotor shaft. Secure the impeller on the shaft with the washer (8), lockwasher (7), and acorn nut (6). While keeping the impeller and shaft from rotating, tighten the acorn nut Position volute (4) flush with oil housing. Assemble suction cover (3) and strainer (2) and secure the assembly with the three bolts (1). 11 a 10 wc_gr wc_tx000114gb.fm 27

28 Maintenance PS / PS / PSA Troubleshooting WARNING Before ordering repairs, carefully read through this manual, then repeat the inspection. If the problem remains, contact your nearest dealer or Wacker representative. ALWAYS turn off the power before inspecting the pump. Failure to observe this precaution can result in serious accident. Problem / Symptom Reason / Remedy Pump will not start Power is off. Restore power. Cable assembly is cut or not connected properly. Repair/ replace the cable or fix the connection. Plug is not inserted. Connect the plug. Impeller is clogged. Inspect the pump and remove any debris. Start float does not operate. Remove any obstruction and check the float operation. Pump stops soon after starting (Motor protector operates) Low voltage. Provide the rated voltage, or make sure the Impeller is clogged. Remove debris. cable assembly extension is the proper standard. Wrong power frequency. Check the nameplate, and replace the pump or the impeller. Extended operation with a clogged strainer. Remove debris from the strainer. Faulty motor (burning, water infiltration, etc.). Repair or replace the motor. Motor protection system was triggered. Identify and correct cause before re-starting. Poor lift or discharge capacity Worn out impeller or suction cover. Repair or replace the worn parts. Sharply bent or clogged hose. Straighten out any sharp bends. Enclose the pump with a screen to keep away debris. Strainer clogged or buried. Remove debris from the strainer, or place a block under the pump. Wrong power frequency. Check the nameplate, and replace the pump or the impeller. Heavy vibration or noise Damaged motor shaft. Contact dealer and replace motor. Pump will not stop automatically Something is interfering with the float operation, or the float switch is faulty. Remove any obstacles, or replace the switch. wc_tx000114gb.fm 28

29 PS / PS / PSA Notes Maintenance wc_tx000114gb.fm 29

30 Technical Data PS / PS / PSA Technical Data 4.1 Standard Specifications Machines discussed in this manual: Machine PS PSA PS BOM Applicable Liquids, Consistency and Temperature Rain Water, Fountain Water, Ground Water, Sand-Carrying Water 0 40 C ( F) Pump Impeller Semi-Vortex Type: (PS 2 500, PSA 2 500) Open Type: (PS 2 750) Shaft Seal Bearing Double Mechanical Seal Shielded Ball Bearing Motor Specification Dry Submersible Induction Motor (2-Pole) Insulation Class E Protection System Miniature Protector: (PS 2 500, PSA 2 500) Circle Thermal Protector: (PS 2 750) Lubricant SAE 10W/20W Such as: Turbine Oil ISO VG #32 Shell Victrolia Oil #27 British Pet Energol THB #32 Gulf Paramount #32 Tellus #T22 Shell Oil Shell Turbo T32 Connection Coupling (NPT 2 ) wc_td000035gb.fm 30

31 PS / PS / PSA Operating Specifications (60 Hz) Technical Data Part No. PS PSA PS Pump Electric Power V/Ph/Hz 110/1/60 220/1/60 110/1/60 110/1/60 220/1/60 Rated Current A Starting Method Capacitor-Run Bore mm (in.) 50 (2) Output kw (Hp) 0.48 (0.66) 0.75 (1) Maximum Head m (ft.) 12 (39.5) 18 (60) Maximum Capacity L/min (GPM) 236 (62.4) 276 (73) Maximum Pressure psi Solid Size Capacity mm (in.) 6 (0.2) Weight* Kg (lbs.) 9.5 (21) 10 (22) 16 (35) * The weight (mass) given above is the operating weight of the pump itself, not including the cable assembly. 4.3 Dimensions 185 (7.3) 185 (7.3) 185 (7.3) 185 (7.3) 185 (7.3) 222 (8.8) 200 (11) 229 (9) 305 (12) 200 (11) 229 (9) 305 (12) 414 (16.3) PS PSA PS wc_gr wc_td000035gb.fm 31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46 Wacker Construction Equipment AG Preußenstraße 41 D München Tel.: +49-(0) Fax: (0) Wacker Neuson Corporation P.O. Box 9007 Menomonee Falls, WI Tel. : (262) Fax: (262) Tel. : (800) Wacker Asia Pacific Operations Skyline Tower, Suite 2303, 23/F 39 Wang Kwong Road, Kowloon Bay, Hong Kong Tel Fax:

Operator s Manual. Pump PS2 500 PSA2 500

Operator s Manual. Pump PS2 500 PSA2 500 Operator s Manual Pump PS2 500 PSA2 500 EN 5000185024 03 1111 5 0 0 0 1 8 5 0 2 4 Copyright notice Copyright 2011 by Wacker Neuson Production Americas LLC All rights, including copying and distribution

More information

Operator s Manual. Pump PS2 800 PSA2 800

Operator s Manual. Pump PS2 800 PSA2 800 Operator s Manual Pump PS2 800 PSA2 800 EN 5000185068 05 0413 5 0 0 0 1 8 5 0 6 8 Copyright notice Copyright 2013 by Wacker Neuson Production Americas LLC All rights, including copying and distribution

More information

en Pump PST2 400 OPERATOR S MANUAL

en Pump PST2 400 OPERATOR S MANUAL 0154624en 005 0708 Pump PST2 400 OPERATOR S MANUAL 0 1 5 4 6 2 4 E N PST2 400 Table of Contents 1. Foreword 4 2. Safety Information 5 2.1 Operating and Electrical Safety... 6 2.2 Information Labels...

More information

en Indirect Lighting System LB 1 OPERATOR S MANUAL

en Indirect Lighting System LB 1 OPERATOR S MANUAL 0163721en 003 0708 Indirect Lighting System LB 1 OPERATOR S MANUAL 0 1 6 3 7 2 1 E N LB 1 Table of Contents Foreword 4 1 Safety Information 5 1.1 Callouts Found in this Manual... 5 1.2 Safety Guidelines

More information

en Generator CARB GP 2600 OPERATOR S MANUAL

en Generator CARB GP 2600 OPERATOR S MANUAL 0163125en 003 0609 Generator CARB GP 2600 OPERATOR S MANUAL 0 1 6 3 1 2 5 E N DANGER CARBON MONOXIDE Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide (CO).

More information

Operator s Manual. Light Balloon LB en

Operator s Manual. Light Balloon LB en Operator s Manual Light Balloon LB 1 0175081en 004 0410 0 1 7 5 0 8 1 E N Copyright notice Copyright 2010 by Wacker Neuson Corporation. All rights, including copying and distribution rights, are reserved.

More information

en Direct oil-fired space heaters HD... Operator's manual

en Direct oil-fired space heaters HD... Operator's manual 0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...

More information

Installation/Instruction Manual

Installation/Instruction Manual 1510876HC8902 Pressurized ventilators (for device cooling) Model Blade diameter (cm) Indoor or outdoor EF-20UYS-UL EF-25UAS-UL EF-30UBS-UL 20 25 30 Indoor Installation/Instruction Manual For customers

More information

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any

More information

OWNERS GUIDE TO INSTALLATION AND OPERATION

OWNERS GUIDE TO INSTALLATION AND OPERATION OWNERS GUIDE TO INSTALLATION AND OPERATION SPM SERIES HIGH POWER CENTRIFUGALS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your pump. Be sure to check

More information

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING 12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING This manual contains very important safety warnings and information. Read and save these instructions for future

More information

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 637 Louisville,

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS SUBMERSIBLE PUMPS MODEL NO: PSV3A, PSV4A, PSSV2A & PVP11A PART NO: 7236042, 7236044, 7236050 & 7236060 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC07/17 iss 4 INTRODUCTION Thank you for

More information

SUBMERSIBLE DIRTY WATER PUMP

SUBMERSIBLE DIRTY WATER PUMP SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP100A, DWP150A, DWP200A PART NO: 7230098, 7230099, 7230100 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS1117 - ISS 2 INTRODUCTION Thank you for

More information

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR PUMP 88 PUMP PARTS BREAKDOWN REF # Order # Mfr # Description 1 NEP4 AC 348 Lid Knobs NEP AC 380 Strainer Lid 3 NEP6

More information

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST Manufacturers of... Quality Products since 1866 95 N. Oak St. Kendallville, IN 46755 1-800-345-9422 DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST FW0771 0116 Supersedes 0415 MODEL: DATE

More information

QUICK PRIME INSTALLATION AND SERVICE MANUAL

QUICK PRIME INSTALLATION AND SERVICE MANUAL QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #

More information

LC Series - Light Commercial Pump Station Installation and Operation Manual

LC Series - Light Commercial Pump Station Installation and Operation Manual LC Series - Light Commercial Pump Station Installation and Operation Manual Please keep this manual with the pump station Content Rain Bird LC Series Overview... Safety Instruction... Operation... 3 Pump

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS Power Shovel Form No. 3362-567 Rev A Model No. 38361 Serial No. 310000001 and Up Operator's Manual If you have questions or problems, call toll free 1-800-808-2963 (US) or 1-800-208-3072 (Canada) before

More information

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP 2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP 8308 PUMP PARTS BREAKDOWN Ref # Part # Manf. # Descrip on 1 NEP2134 AC 81361 PUMP LID 2 NEP2135 AC 81396 PUMP LID

More information

MD SERIES Instruction Manual

MD SERIES Instruction Manual IWAKI Magnetic Drive Pump MD SERIES Instruction Manual Read this manual before use of product Thank you for having selected the Iwaki Magnetic Drive Pump MD series. This manual deals with the correct handling

More information

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333 User Guide Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE 100 #728492 1056 #728320 FOR PUMP MODELS 185 264 396 633 #728300 #728305 #728310 #728315 1267 #728325 1584 #728330 2245 #728333 Fixed Flow Pumps

More information

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP 8104 MAXI-PUMP PARTS BREAKDOWN Re f # 1 2 3 4 5 6 7a 7b 8 9 10 11 12 13 14 15 16 2 Part # NEP2134 NEP2135

More information

en Inverter FU 4/5. Operator s Manual

en Inverter FU 4/5. Operator s Manual 0201424en 006 12.2012 Inverter FU 4/5 Operator s Manual Manufacturer Wacker Neuson Produktion GmbH & Co. KG Preußenstraße 41 80809 München www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax: +49-(0)89-354

More information

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps Safety Important Safety Instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. Save this

More information

Register at

Register at Power Shovel Model No. 38361 Serial No. 313000001 and Up Register at www.toro.com. If, after carefully reading this manual, you still have questions or problems, call toll free 1-800-808-2963 (US) or 1-800-808-3072

More information

QUICK PRIME INSTALLATION AND SERVICE MANUAL

QUICK PRIME INSTALLATION AND SERVICE MANUAL QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #

More information

PS2 500 PS2A 500 PS2 750

PS2 500 PS2A 500 PS2 750 Operator s Manual Pump PS2 500 PS2A 500 PS2 750 Type PS2 500, PS2A 500, PS2 750 Document 5000187791 Date 1115 Version 04 Language EN 5 0 0 0 1 8 7 7 9 1 Copyright notice Trademarks Manufacturer Original

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the

More information

PUGMILL/MIXER. Instruction Manual NVS-07

PUGMILL/MIXER. Instruction Manual NVS-07 92895B PUGMILL/MIXER Instruction Manual NVS-07 Attention After carefully reading this manual, be sure to store it in a safe and convenient place for easy reference. Before using this unit, please read

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

BULL INSTRUCTION MANUAL. Model Number: BC-130 REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

BULL INSTRUCTION MANUAL. Model Number: BC-130 REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. BULL INSTRUCTION MANUAL Model Number: BC-130 REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. 1 REFRIGERATOR SAFETY Your safety and the safety of others are

More information

PBX series OPERATION MANUAL

PBX series OPERATION MANUAL Submersible pump for pumping sandy water PBX series OPERATION MANUAL Thank you for purchasing a KOSHIN submersible pump. This instruction manual contains cautionary points for using the pump safely. Be

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RF/U/2017 (ENGLISH) (valid since 13.10.2017) ROOF FANS RF / RFV Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the right to modify this

More information

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-71 SinkSpa JETTED SINK Model LJD1306L JOB AID Part No. 8178201 FORWARD This Whirlpool Job Aid, SinkSpa Jetted Sink, (Part No. 8178201), provides the

More information

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. INSTRUCTION MANUAL Model Number: FR551 REFRIGERATOR-FREEZER (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. Igloo has a policy of continuous

More information

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

REFRIGERATOR SAFETY. Your safety and the safety of others are very important. REFRIGERATOR SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages.

More information

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug

More information

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG) WET/DRY VACUUM Operating Instructions (ENG) MODEL: T1 y QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO 9001. Read these instructions before operating the machine.

More information

Owner s Manual Window Air Conditioner

Owner s Manual Window Air Conditioner Owner s Manual Window Air Conditioner G17-5MCVWAC1 G16-5MCVWAC Write the model and serial numbers below for your records: Model # Serial # Date Purchased Please read the entire manual carefully to ensure

More information

Service Manual Washing Machine

Service Manual Washing Machine Http://global.midea.com.cn Service Manual Washing Machine Note: Before serving the unit,please read this at first, Always contact wih your service center if meet problem. TABLE OF CONTENTS 1. SAFETY PRECAUTION...

More information

SM-909/SM /2" Sweat 3/4" Sweat 3 3/8" F.L. Max. Max. Line Weight Model No. HP Inlet/Outlet Volts Amps Fluid Temp. Pressure (Lbs.

SM-909/SM /2 Sweat 3/4 Sweat 3 3/8 F.L. Max. Max. Line Weight Model No. HP Inlet/Outlet Volts Amps Fluid Temp. Pressure (Lbs. Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual

More information

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405 CARBON SPOT 30 EXTRACTOR OPERATOR'S MANUAL IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405 Diamond Products www.diamondproductsus.com Printed in the U.S.A.

More information

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 RECORD THIS INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number ADB Model Number ADB Serial Number Date Purchased USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

More information

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM 216279-000 rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM IDENTIFYING YOUR SYSTEM IOM216279-000 The HOTSTART heating system is designed to heat fluids for use in marine

More information

This label warns for risk of electrical shock when failing to observe.

This label warns for risk of electrical shock when failing to observe. MANUAL horizontal centrifugal pumps MB series ic drive SB series mechanical seal 1. Introduction 2. Safety precautions 3. Receipt 4. Installation / Operation and Maintenance 4.1 Installation 4.2 Operation

More information

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95 Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B-95 394A-95 thru 394D-95, 399A-95 Please read and save this Repair Parts Manual. Read this manual and the General Operating

More information

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMPS OPERATING & MAINTENANCE INSTRUCTIONS SUBMERSIBLE WATER PUMPS Model Nos. HIPPO-3 and 3A 6/97 Thank you for purchasing this CLARKE, HIPPO Submersible Pump. These highly efficient pumps are designed for pumping

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.

More information

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS CAUTION RISK OF INJURY! READ MANUAL BEFORE OPERATING! This manual is an important part of the Corona Discharge Ozone Generator and must remain

More information

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different. RADS-51J RADS-61J Owner s Manual Room Air Conditioner with R-410A Heat Controller, Inc. 15 16 Contact an authorized service technician for repair or maintenance of this unit. Contact an authorized installer

More information

Outdoor Beverage Center

Outdoor Beverage Center ON/OFF SET TEMPERATURE Outdoor Beverage Center Use and Care Guide Be sure unit is standing upright 24 hours prior to plug-in. Model: BBQ10715 IMPORTANT SAFEGUARDS Read all instructions before using this

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. INSTRUCTION MANUAL Model Number: DX-48.130K Wine Cooler CAUTION: BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. TABLE OF CONTENTS 1. WINE COOLER SAFETY...114 2. IMPORTANT

More information

Electronic Service Manuals

Electronic Service Manuals Electronic Service Manuals This electronic document is provided as a service to our customers. We do not create the contents of the information contained in this document. Should you have detailed questions

More information

690 and Power Fishing Systems

690 and Power Fishing Systems INSTRUCTION MANUAL 690 and 690-22 Power Fishing Systems Includes Serial Number AAR 3800 and higher (120 volt model) Includes Serial Number AAT 00500 and higher (220 volt model) Read and understand all

More information

sta-rite Call C and CC Series Installation/Operation/Parts For further operating, installation, or maintenance assistance:

sta-rite Call C and CC Series Installation/Operation/Parts For further operating, installation, or maintenance assistance: OWNER S MANUAL Centrifugal Pumps sta-rite C and CC Series 2791 0397 Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-888-782-7483 293 WRIGHT STREET, DELAVAN,

More information

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts

More information

Operator s Manual. Portable Generator GP 6600A GPS 6600A

Operator s Manual. Portable Generator GP 6600A GPS 6600A Operator s Manual Portable Generator GP 6600A GPS 6600A EN 5000192975 01 0511 5 0 0 0 1 9 2 9 7 5 Copyright notice Copyright 2011 by Wacker Neuson Production Americas LLC All rights, including copying

More information

568X, 587X, 588X Series

568X, 587X, 588X Series Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch OPERATION & MAINTENANCE MANUAL IMPORTANT! Read before proceeding! Please read and save these instructions. Read carefully before

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800 KQ Series Multistage Booster Pump System Installation Manual KQ200/400 KQ800 ISO 9001 Certified Description The KQ series booster pump is an all-in-one compact and reliable automatic multistage centrifugal

More information

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series PumpAgents.com - Click here for Pricing/Ordering Model 6050-Series SELF-PRIMING PUMPS FEATURES Body: Impeller: Shaft: Wearplate: Shaft Seal: Ports: Motor: Weight: Bronze Construction JABSCO Nitrile 316

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

V80-H Multistage Pump Instruction Manual

V80-H Multistage Pump Instruction Manual V80-H Multistage Pump Instruction Manual PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming

More information

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION

More information

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2 CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2 Congratulations on your purchase of a LEO Centrifugal Pump It is important that you read, fully understand and observe the following

More information

APW PSI PRESSURE WASHER

APW PSI PRESSURE WASHER APW5001 1300 PSI PRESSURE WASHER 1300 PSI PRESSURE WASHER Please carefully read this manual which has been specifically designed to provide all the necessary information for the correct use of the machine,

More information

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING Series 47 and 247 Mechanical Water Feeders McDonnell & Miller Installation & Maintenance Instructions MM-316(C) Series 47-2 and 247-2 Combination Mechanical Water Feeder/Low Water Cut-Off Series 47 Water

More information

Grinding mill MISTRAL 50L (art. 650P)

Grinding mill MISTRAL 50L (art. 650P) Grinding mill MISTRAL 50L (art. 650P) USE AND MAINTENANCE MANUAL RIVER SYSTEMS SRL Via Marco Polo, 33-35011 Campodarsego (Padova) Italy Tel. +39-049-9202464 - Fax: +39-049-9216057 - e-mail: info@riversystems.it

More information

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

S SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16 Webster Pumps "S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16 PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING Webster PUMPS or HAYWARD VALVES,

More information

INSTRUCTION MANUAL FOR DUTCHESS MODEL 260 BAGEL & BUN SLICER

INSTRUCTION MANUAL FOR DUTCHESS MODEL 260 BAGEL & BUN SLICER INSTRUCTION MANUAL FOR DUTCHESS MODEL 260 BAGEL & BUN SLICER Table of Contents Safety Information I thru VII Uncrating Instructions 1 Introduction 2 Adjustment Instructions 3 Operating Instructions, Cleaning,

More information

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No: CLEAN WATER PUMP MODEL No: Hippo4A Part No: 7230535 OPERATION & MAINTENANCE INSTRUCTIONS 0807 INTRODUCTION Thank you for purchasing this CLARKE clean water pump. This highly efficient pump is designed

More information

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL SWP (Models SWP08 through SWP20) OPERATION & MAINTENANCE MANUAL IMPORTANT! Read before proceeding! Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Pool Power Pak. III with On/Off Switch UL Models (1 HP), (1-1/2 HP) NEC Models (1 HP), (1-1/2 HP)

Pool Power Pak. III with On/Off Switch UL Models (1 HP), (1-1/2 HP) NEC Models (1 HP), (1-1/2 HP) the original portable pool Pool Power Pak III with On/Off Switch UL Models 0-1076-000 (1 HP), 0-1077-000 (1-1/2 HP) NEC Models 0-1076-006 (1 HP), 0-1077-006 (1-1/2 HP) Owner's Guide 365-1783 PREPARATION

More information

Panel Fan Series Operators Manual (Galvanized and Polymer)

Panel Fan Series Operators Manual (Galvanized and Polymer) Panel Fan Series Operators Manual (Galvanized and Polymer) Galvanized Panel Fan with Three Wing Blade IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before attempting to assemble,

More information

PJ130S High Pressure Cleaner

PJ130S High Pressure Cleaner PJ130S High Pressure Cleaner Operator Manual Original instructions WARNING: Do not use the machine without reading the instruction sheet. Item Description OVERVIEW 1. High pressure washer 2. On/off switch

More information

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING. Eagle Pump Owners Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. INSTALLATION... 2 SECTION II. OPERATION & MAINTENANCE... 2 SECTION

More information

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference. OWNER S MANUAL DEHUMIDIFIER ESPAÑOL FRANÇAIS Read this manual carefully before operating the appliance and retain it for future reference. Model : UD701KOG1 P/NO : MFL68026017 www.lg.com TABLE OF CONTENTS

More information

Installation. Built-in Full Height Wine Cellar VCWB301

Installation. Built-in Full Height Wine Cellar VCWB301 Installation Built-in Full Height Wine Cellar VCWB301 Table of Contents Warnings & Important Information _ 3 Dimensions _ 5 Specifications _ 6 Cutout Dimensions 7 Cabinet Information _ 8 Cabinet Information

More information

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS Domestic Washer Technical Information 120 V, 60 Hz Models SAV2555AW* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.

More information

Nichole Ernst CEO Powerhouse International

Nichole Ernst CEO Powerhouse International Dear Valued Customer, Thank you so much for your order. We are a family-owned business in Lincoln, NE and customer service is our priority. If you have any questions about your product, please feel free

More information

DIRTY WATER SUBMERSIBLE PUMP

DIRTY WATER SUBMERSIBLE PUMP WHAT S IN THE BOX DIRTY WATER SUBMERSIBLE PUMP 780W INSTRUCTION MANUAL SPECIFICATIONS Motor: 780W Max. Flow Rate: 15,700l/h Max. Head 8m Max. Immersion: 7m Min. Suction Depth 50mm Max Particle Size: Ø35mm

More information

Installation Guide BI-98 Ice Maker www.u-lineservice.com Phone (414) 354-0300 FAX (414) 354-7905 Service & Parts Tech Lines Phone (800) 779-2547 FAX (414) 354-5696 OnlineService@U-Line.com 2005 U-Line

More information

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324 Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324 To prevent accidents, which could cause serious injury or death, as well as machine damage read these instructions before installation

More information

Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER

Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER ENGLISH ESPAÑOL Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER MODEL : LP0817WSR LP1017WSR LP1217GSR LP1417SHR LP1417GSR

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS 1800 Power Curve Snowthrower Model No. 38381 Serial No. 313000001 and Up Form No. 3373-449 Rev A Operator's Manual Register your product at www.toro.com IMPORTANT SAFETY INSTRUCTIONS When using an electrical

More information

Service Manual. Note: Before service the unit, please read this manual first. Contact with your service center if meet problem

Service Manual. Note: Before service the unit, please read this manual first. Contact with your service center if meet problem Kleenmaid Dryer Model:KCDV60 Service Manual Note: Before service the unit, please read this manual first. Contact with your service center if meet problem Contents 1 PRECAUTION....3 1.1 Safety Precautions

More information

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP Model T00405 REPAIR PARTS REF. PART DESCRIPTION REF. PART DESCRIPTION 1 450331 Strainer 2 450332 Oil cover "O" ring 3 400447 Impeller 4 450333 Pump casing 5 400450 Oil cover 6 400449 Oil seal 7 400448

More information

SPECIFICATIONS FEATURES

SPECIFICATIONS FEATURES FEATURES Excellent for collecting the large chips which will drop into the garbage can before reaching the impeller. The filter bag filters out the remaining sawdust down to 5 microns. With the cyclone

More information

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS HT650 TM FAN DRIVE SERVICE INSTRUCTIONS When unpacking your product, remove all components and inspect them to ensure that no damage occurred during shipping. If any components are missing or damaged,

More information

Installation Instructions Remote Blowers

Installation Instructions Remote Blowers Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor hood assembly or

More information

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming pumps. They warrant high hydraulic and

More information

MERCHANT POPCORN MACHINE SERVICE MANUAL

MERCHANT POPCORN MACHINE SERVICE MANUAL 3243 North California Avenue, Chicago, IL 60618 MERCHANT POPCORN MACHINE SERVICE MANUAL 120 Volt, Single Phase, 60 Hz 230 Volt, Single Phase, 50 Hz READ and UNDERSTAND this servicing, and safety instructions

More information

INSTRUCTION AND REPAIR MANUAL

INSTRUCTION AND REPAIR MANUAL SECTION 6 ITEM 390 DATED JANUARY 2003 SUPERSEDES SECTION 6 ITEM 390 DATED OCTOBER 2000 INSTRUCTION AND REPAIR MANUAL SERIES 390 6 The 390 Series is a superior commercial Multi-Stage Vertical In-Line Centrifugal

More information

SUPPLEMENTARY INSTRUCTIONS

SUPPLEMENTARY INSTRUCTIONS www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com SUPPLEMENTARY INSTRUCTIONS MODEL 450475 Dear consumer, We thank and congratulate

More information

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99) Flood Pumper Plus Water Transfer Machine Model No.: 607841 Operator and Parts Manual NOBLES 12875 RANSOM STREET HOLLAND MI 49424 U.S.A. CUSTOMER SERVICE: 1-800-365-6625 FAX: 1 800 678 4240 608468 Rev.

More information