VACUUM PUMP Micro Cartridge Pump
|
|
- Shanna Evangeline Charles
- 6 years ago
- Views:
Transcription
1 Pump Max. vacuum level : -85 kpa Max. flow rate : 6.5 NI/min Supply air pressure :.~.6 bar, max 7bar (43.5~87 psi, max 0.5 psi) Air consumption : 6.8~0.6 NI/min Supply air type : Dry compressed air Working temperature : - 0ºC ~ + 80ºC Noise level : 50 ~ 60dBA Feature Integrated with VMECA vacuum cartridge Low Energy consumption & Saving cost Compact (0mm) design with Light weight High vacuum level (Max. -85kPa) in low compressed air (~3bar) Modular system Quick response time & High flow Integrated with air control valve & vacuum release valve Push-in type direct hose fitting Easy to assemble & disassemble control valve unit Order No. MC 0 - M4 - A - PG 3 4 Model MC 0 - Micro cartridge VC0 3 Valves Air Supply Vacuum Release A (N.C. : Normal Closed) (N.C. : Normal Closed) B (N.C. : Normal Closed) - Body type S - Single unit M - Stack No mark - - Only CL type valve is available Remark : No mark is not available for Manifold type M4-4Stack 4 Vacuum Switch M6-6Stack No mark - Starndard (P)C - M8-3Pin Connector type M8-8Stack (P)G - LED wire type(3m lead wire) M0-0Stack Remark : (P) Output type : PNP open collector VCM8 4 : ㆍM8-3pin female connector ㆍAvailable for C or PC type 5 Sealing No mark - Starndard (NBR) V - Viton E - EPDM Specifications subject to change without notice.
2 Control Unit (for Micro Pump) Pressure range Mpa(kgf/cm²) : 0~0.7 (0~7) Inner shock / vabration (m/s²) : 300 / 50 Supply air type : Dry compressed air Working temperature : - 0ºC ~ + 80ºC electrical power consumption (W) Feature Integrated with VMECA vacuum cartridge Low Energy consumption & Saving cost Compact (0mm) design with Light weight : Standard (Lamp, rated voltage approval) Power saving mode High vacuum level (Max. -85kPa) in low compressed air (~3bar) Modular system Quick response time & High flow Integrated with air control valve & vacuum release valve Push-in type direct hose fitting Easy to assemble & disassemble control valve unit Order No. CU 0 - M4 - A - PG 3 4 Model CU 0 - Body type Control Unit for Micro cartridge VC0 3 Valves Air Supply Vacuum Release A (N.C. : Normal Closed) (N.C. : Normal Closed) B (N.C. : Normal Closed) - Only CL type valve is available S - Single unit M - Stack M4-4Stack M6-6Stack M8-8Stack M0-0Stack 4 Vacuum Switch No mark - Starndard (P)C - M8-3Pin Connector type (P)G - LED wire type(3m lead wire) Remark : (P) Output type : PNP open collector VCM8 4 : ㆍM8-3pin female connector ㆍAvailable for C or PC type 5 Sealing No mark - Starndard (NBR) V - Viton E - EPDM Specifications subject to change without notice.
3 Vacuum Flow (Nl/m) Vacuum Flow (Nl/m) VACUUM PUMP Pump Performance Data Model Max. Vacuum -kpa (-mmhg) Supply Air pressure (MPa) 0 (0) Vacuum flow (Nl/min) at different vacuum level kpa (-mmhg) 0 (75) 0 (50) 30 (5) 40 (300) 50 (375) 60 (450) 70 (55) 80 (600) 90 (675) VC Model Supply Air pressure (MPa) Consumption (Nl/min) 0 (75) Time, s/l, to evacuate a volume to different vacuum level kpa (-mmhg) 0 (50) 30 (5) 40 (300) 50 (375) 60 (450) 70 (55) 80 (600) 90 (675) VC Vacuum flow (Nl/min) at different vacuum level 0.Mpa 0.Mpa 0.6Mpa Evacuation time 0.Mpa 0.Mpa 0.6Mpa Vacuum level (-kpa) Vacuum level (-kpa) Application 3 Specifications subject to change without notice.
4 Dimension Standard MC 0 - S M5 Valve & Switch type MC 0 - S - C - PG Specifications subject to change without notice. 4
5 Dimension Valve & Switch type MC 0 - S - A - PG Vacuum Release Valve Air Supply Manifold type MC 0 - M6 - A - PG Vacuum Release Valve Air Supply 5 Specifications subject to change without notice.
6 Dimension Control unit for MC0 CU 0 - M4 - A - PG Vacuum Release Valve Air Supply Specifications subject to change without notice. 6
MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI
MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI Intermediate modules are non-independent multi-stage and multi-function vacuum generators to be assembled to the generators
More informationVACUUM PUMPS VSM 진공펌프
VACUUM PUMPS VSM 진공펌프 VSM VACUUM PUMPS Feed pressure.4 ~.6 MPa Air consumption 15 ~ 126Nl/m Max vacuum -85 kpa Noise level ~ 65 dba Material PPS, AL Working temperature - ~ Weight 43 ~ 68 g Order no. VSM
More informationMVG. Modular Vacuum Grippers. US5
Modular Vacuum Grippers MVG www.coval.com US5 MVG COVAL s MVG Series: Customized Customized Solution COVAL s MVG series vacuum grippers correspond perfectly to the expectations of integrators and users:
More informationAir. Pressure. Motion. nnnnnnnn
Air. Pressure. Motion. nnnnnnnn AIRTEC classic ejectors Page 10.001 AIRTEC column ejectors Vacuum generators with 1, 4, 6 and 8 independent vacuum circuits. Series HV and HF Page 10.010 MI and MIF Page
More informationSelf-regulating vacuum pumps. Characteristics. bar (Nl/s) Specifications
GVMAX V3 series Self-regulating (electric vacuum and blow-off control) Branch-specific applications Applications The two solutions, GVMAX SP345V3 and GVMAX SP345V3R are used for gripping air-tight objects
More informationVacuum generation Content
Vacuum generation Content Inline ejectors... 513 Base and Heavy-duty ejectors... 526 Multi-chamber ejectors... 546 Compact ejectors... 555 Feed ejectors... 569 Silencers for vacuum ejectors... 577 Rotary
More informationmulti-stage vacuum generators - general information
multi-stage vacuum generators - general information Our multi-stage vacuum generators produce a maximum vacuum of 90%, equal to a final vacuum level of 100 mbar abs., with different suction capacities.
More informationControl unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr
Control unit PPT/RS,, 0111636 Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and control unit is 10 metres when feed pressure is 0.6 MPa.
More informationVacuum generators VADM/VADMI
Key features Product overview Vacuum generators All Festo vacuum generators have a single-stage design and operate according to the Venturi principle. The product series described below have been designed
More informationMMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated
6 available sizes Integral suction lifter Accessories Lightning fast suction for lifting and moving with only on vaccum line s Vacuum-operated Integral suction lifter Compressed-air Page 3-01.. Page 3-02..
More informationRA 2000 Series RA 15/6T & TB Conversion Valve
RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water
More informationFIPA Vacuum Components
213.K1-ER English February 213 FIPA Vacuum Components Addendum Version 1 www.fi pa.com Editorial Only those who think ahead stay ahead Competence in Vacuum Technology Based in Ismaning near Munich, FIPA
More informationRA15/6T & TB Conversion Valve
Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from
More informationREFRIGERANT SYSTEM SERVICE WARNINGS
2005 HVAC Refrigerant System - MX-5 Miata REFRIGERANT SYSTEM SERVICE WARNINGS USING/HANDLING UNAPPROVED REFRIGERANT Using a flammable refrigerant, such as OZ-12, in this vehicle is dangerous. In an accident,
More information5/12/2018 Climate Control System General Information and Diagnostics - Air Conditioning (A/C) System Recovery, Evacuation and Charging - G
2008 Fusion Subarticles Report a problem with this article Refrigerant System Recovery Refrigerant System Evacuation Using a R-134a Refrigerant Management Machine Refrigerant System Evacuation Using a
More informationPORTABLE DEW POINT MONITOR
PORTABLE DEW POINT MONITOR MODEL 8072, 8072-230VAC (units made after 2002) Table of Contents INTRODUCTION... 2 SPECIFICATIONS:... 2 OPERATION... 3 Dryer Output Sampling... 3 Hopper Output Sampling... 3
More informationSECTION 50 - CAB CLIMATE CONTROL
AIR CONDITIONING SYSTEM DYNAMIC DESCRIPTION The refrigerant circuit of the air conditioning system contains five major components: Compressor, Condenser, Receiver/Drier, Expansion Valve, and Evaporator.
More informationNT 27/1. Cartridge filter with float. Robust bumper
NT 27/1 The NT 27/1 is a powerful wet/dry vacuum cleaner for professional users. It is exceptionally compact and comes standard with a number of useful accessories. 1 Cartridge filter with float 3 Robust
More informationPremium Micro Desoldering station
www.jbctools.com English Premium Micro Desoldering station Ref. DSS-D Packing List The following items should be included: DI Control Unit... 1 unit Ref. DI-1D (120V) DI-2D (230V) DI-9D (100V) Electric
More informationDigital LEAD FREE. Soldering Soldering. Temperature range. Station. N1-06 Nozzle ø0.6 N1-08 Nozzle ø0.8 N1-10 Nozzle ø1.0 N1-13 Nozzle ø1.3. ø2.
Desoldering Tool High-Power Desoldering Tool Digital Nozzle not included N2 Soldering Soldering (Option) (Option) Desoldering Vacuum pump built-in type desoldering tool Digital display ensures easy and
More informationSpare Parts List (Kits) Model Ref.:- HM35 SERIES A Spare Parts List (Kits) Issue 8 Dated 10-February-2015 Reference Drawing 09-1108-0000 Issue B Dated 07-January 2014 Drawing Ref. Part Number DESCRIPTION
More informationTemperature control of individual floor-heated rooms or mixed floor-heating/radiator systems
FHV regulating valve Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems Application FHV control valves are ideally suited to the temperature control of individual
More informationHEATING AND AIR CONDITIONING
WJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page SERVICE PROCEDURES REFRIGERANT OIL LEVEL...1 REFRIGERANT RECOVERY....1 REFRIGERANT SYSTEM CHARGE...1 REFRIGERANT
More informationNT 27/1. Cartridge filter with float. Robust bumper. Robust metal latches
NT 27/1 The NT 27/1 is a powerful wet/dry vacuum cleaner for professional users. It is exceptionally compact and comes standard with a number of useful accessories. 1 Cartridge filter with float 3 Robust
More information16. Hose Replacement. Disconnect power supply to the AR400.
16. Hose Replacement The AR400 is equipment with external hoses such as R-12 Low and High Service hoses, R-134 Low and High Service hoses, Tank hoses and vacuum pump hose. The unit also utilizes internal
More informationVacuum mixers Wamix-Classic and Wamix-Injector
Novelties 2012 Vacuum mixers Wamix-Classic and Wamix-Injector It s all in the mixing! Model production Wamix-Classic with accessory table stand Technical information Powerful, compact and innovative: The
More informationTechnical Datasheet. Suction Controllers, Flow Meters & Accessories
Suction Controllers, Flow Meters & Accessories Pneumatech MGS s, vacuum suction units and accessories are designed for connection to medical gas terminal units, providing the interface between patient
More informationVacuum related component model series variation
Vacuum related component model series variation Vacuum related components Vacuum pad Vacuum ejector/vacuum unit VSLF series VSFB Series VSFU Series Series
More informationKIT-UR-V. IST-KIT-UR-V Page 1 of 12 REVISIONS DOCUMENT LAYOUT MOUNTING INSTRUCTIONS AND OPERATING MANUAL
Page 1 of 12 MOUNTING INSTRUCTIONS AND OPERATING MANUAL KIT-UR-V REVISIONS DATE REVISION MAIN CHANGES 2017/10/17 Edition A First release Description Exploded view drawing of the final assembly Itemized
More informationAIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS
AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS CT2831.0_00 EN April 2015 * Airterm Dirt Airterm Mag * o Removes any impurity o Self-cleaning o Ensures system efficiency
More informationPremium Desoldering station with Electric Pump
English Premium Desoldering station with Electric Pump Ref. DIS-D Packing List The following items should be included: DI Control Unit... 1 unit Ref. DI-1D (120V) DI-2D (230V) DI-9D (100V) Electric Desoldering
More informationInstruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS
English Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Instruction Manual
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART
More informationLow air consumption vacuum generators
Low air consumption vacuum generators Regulated venturis, series GVMAX Electric Gripping display LED 168 50.2 35 61 ø.2 Exhaust 1/2 Gas 1/ Gas or Quick-connect 68 8 5.5 bar compressed air network 35 56.7
More informationWiring Transmitter and Detectors. mounting hole. A023a. mounting hole. A024a
Standard type Wiring and Detectors / Standard type for DC 3-wire and DC 2-wire Detector type Number of Detector 4 detectors 44 (23) () P=28x3=84 A023a Type Code RPK-22 Material Body Aluminum die casting
More informationIntrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20
Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical
More information8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.
8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. FUNCTION: Circulation units for solar thermal systems are used in the primary circuit of solar heating systems to control the temperature
More information16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10
Ionizer Nozzle type Series IZN10 Electrode needle contamination detector Outputs maintenance signal when detects stain or wear of an electrode needle always. Detects optimal maintenance time, reduced labor
More informationNT 35/1 Ap. ApClean (semi-automatic filter cleaning system) Practical cable storage compartment. Mobility and power
NT 35/1 Ap The NT 35/1 Ap is based on the same platform as the NT 25/1 Ap, has 10 liters more container capacity and is the successor to the NT 361 Eco. 1 2 3 4 1 2 ApClean (semi-automatic filter cleaning
More informationProductinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG
Productinformatie A.U.K. MÜLLER GMBH & CO. KG Product Series 1.010.6 A. u. K. Müller Solenoid valves Control valves Special valves and systems A. u. K. Müller GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany
More informationVACUUM TECHNIQUE CATALOGUE 5.0 VACUUM A RESOURCE FOR EVERYONE. I N N O V A T I V E S O L U T I O N S I N V A C U U M T E C H N I Q U E
VACUUM TECHNIQUE I N N O V A T I V E S O L U T I O N S I N V A C U U M T E C H N I Q U E CATALOGUE 5.0 Vacuum grippers Suction cups Vacuum pumps PVA TM VACUUM A RESOURCE FOR EVERYONE Accessories www.piab.com
More informationpremium line Stations Different equipment designed for a specific soldering or rework job
premium line Stations Different equipment designed for a specific soldering or rework job Premium line stations are designed for extensive industrial use, with extraordinary thermal performance. They are
More informationPressure Transducers Ultrahigh-Purity
www.swagelok.com Pressure Transducers Ultrahigh-Purity PTU Series Single-end, flow-through, and modular surface-mount models Positive pressure ranges to 5000 psi, 400 bar, and 40 MPa; compound pressure
More informationVACUUM VALVES AND HOSES
VACUUM VALVES AND HOSES 5046 Vacuum Valve Two-piece 500 F (260 C) industry standard 5255 Vacuum Valve Three-piece 500 F (260 C) industry standard SS5700 Stainless Steel Vacuum Valve Three-piece 1000 F
More informationThe Safest Connections...
The Fluid Manager The Safest Connections... The Lutz Accessory Range for Electrical & Pneumatic Drum, Tote and Container Pumps A c c e s s o r y R a n g e Accessory Range Safety is our Concern At a glance
More informationSelf-regulating vacuum pumps. Characteristics. Ø max. vacuum air drawn in L2 model nozzle (%) Specifications. Curves: see page 9/27.
Branch-specific applications (electric vacuum and blow-off control) Description The communication between both elements, electronic vacuum switch and gripping valve control allows the consumption of compressed
More informationPhone: Fax :
PT JOTAM Phone: +62 21 451 3089 Fax : +62 21 451 5743 Email : jotam@cbn.net.id A better solution for conveying bulk material PIAB is a leader in developing innovative vacuum technology for use in automated
More informationSIHI Dry GD S Sizes S450, S650
SIHI Dry GD S Sizes S450, S650 Single Stage Vacuum System - General Design Dry Running Screw Vacuum Pump Experience In Motion Pressure range: Pumping Speed: < 0.001 to 1013 mbar 0.00075 to 760 torr 450
More informationRPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:
GE Oil & Gas RPS/DPS 8000 High Accuracy Resonant Pressure Sensor Since 1972, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace,
More informationUser manual Flushing device VAS 6337/1a
User manual Flushing device VAS 6337/1a 2 Content Safety warnings 3 Flushing with R134a refrigerant 4 1.0 Preparing the Vehicle AC System 4 1.1 Connecting the recovery recharge Unit 6 1.2 Flush procedure
More informationCharacteristics. Ø nozzle. model
GVP series Modular vacuum pumps Branch-specific applications Advantages ncan be adapted to all branches noptimized performance for handling all types of objects nmodular design thanks to the different
More informationIntroduction pisave optimize pisave onoff pisave release pisave sense pisave restrict...488
479 pisave Introduction...480 pisave optimize...482 pisave onoff...484 pisave release...486 pisave sense...487 pisave restrict...488 480 pisave Introduction pisave For pump/system Air saving Control Included
More informationPD10. Serial Plates with Side Ports for ISO Valves. Technical Features. Technical Data. Functional Description. Page 1. Size 10 (D05) p max
Serial Plates with Side Ports for ISO 4401-05 Valves PD10 Size 10 (D05) p max 250 bar (3600 PSI) Technical Features ISO 4401-05-04-0-05 46(1.81) ed to connect in parallel two or more ISO 4401-05 (CETOP
More informationBarrier Washer. Parts. Refer to Page 3 for Model Numbers. BAR17P_
Barrier Washer Refer to Page 3 for Model Numbers Parts BAR17P_1300622 www.alliancelaundry.com Part No. 1300622R4 November 2014 Table of Contents Title Page Parts Ordering Information... 2 Serial Plate
More informationNew TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system
New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system TERMOVAR LOADING UNIT is a pre-fabricated,
More informationRPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:
GE Measurement & Control RPS/DPS 8100 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial,
More informationMin Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off
Modular Venturi Vacuum Pumps Min Series Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off In keeping pace with industry s need for improved automation and material handling methods,
More informationMiniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet
Miniature Low Pressure Sensors 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi Datasheet Miniature Low Pressure Sensors The 24PC Series Miniature Pressure Sensors are small, cost-effective devices
More informationHITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION. This specification is applied to SHANGHAI HITACHI rotary compressor. 2.
HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION Page 1. 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor. 2. SPECIFICATION OF COMPRESSOR 2.1 Model SG153BG3GC 2.2
More informationMeasurement Solutions for Refrigeration Technology.
Measurement Solutions for Refrigeration Technology. Digital manifold, leak detection, vacuum measurement, and lots more. 01_Brochure_testo552_MASTER.indd 1 30.01.2013 11:27:13 Testo refrigeration technology
More informationREFRIGERANT ON-VEHICLE INSPECTION AC 14
14 REFRIGERANT ON-VEHICLE INSPECTION 1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET (a) This is a method to specify trouble areas by using a manifold gauge set. Read the manifold gauge pressure
More informationMeasurement Solutions for Refrigeration Technology.
New: now with App and Bluetooth. Measurement Solutions for Refrigeration Technology. Complete solution for the commissioning and maintenance of refrigeration systems and heat pumps. testo 549, testo 550,
More informationACORE Filtration Co.,Ltd provides engineering,
Oil Filtration Systems For Every Demanding Application VLF Lube Oil Purifier ACORE Filtration Co.,Ltd provides engineering, manufacturing, sales of industrial oil filtration systems, we have been striving
More informationConnectors for Optic Fibre Cable
Connectors for Optic Fibre Cable Direct Buried Connectors and End Caps Push-In Fittings 6270 Page 1-75 6270..03 Page 1-75 6273 Page 1-75 6273..03 Page 1-75 Direct Install Connectors and End Caps 6271 Page
More informationConveyors C. Conveyors C
Vacuum is used with great advantage in order to convey dry powder products through dedicated pipe systems. PIAB s vacuum conveying systems are built of strong components of high quality. Our objective
More informationINSTALLATION & MAINTENANCE
INSTALLATION & MAINTENANCE MODELS: UVG SLT 2 (GT7-2UVG) UVG SLT 30 (GT7-4UVG) UVG SLT 40 (GT7-8UVG) UVG SLT 75 (GT7-13UVG) UVG SLT80 UVG SLT125 (GT7-15UVG) and UVG SLT 172 Stainless Steel Water Disinfection
More informationUSER MANUAL UR500VAC UR480VAC UR500VAC-E UR480VAC-E UR500VAC-A UR500VAC-J AUTOMATIC DUST VACUUMS MODELS UNI-RAM CORPORATION ONTARIO CANADA
USER MANUAL AUTOMATIC DUST VACUUMS MODELS UR500VAC UR480VAC UR500VAC-E UR480VAC-E UR500VAC-A UR500VAC-J UNI-RAM CORPORATION ONTARIO CANADA Revised 2006-02 CONTENTS INTRODUCTION... 3 CAUTIONS AND WARNINGS...
More informationHNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI
NO. S051-800 ISSUED: MAR. 26, 2010 REVISED: HOSHIZAKI COUNTER SHOWCASE MODEL HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B SERVICE MANUAL IMPORTANT This manual should be read carefully
More informationVacuum suction nozzle OVEM-...-1P/1N
Vacuum suction nozzle OVEM-...-1P/1N Operating instructions (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com 8085608 2018-01b
More informationAir operated diaphragm pumps. Catalogue 2011 rev 1
Air operated diaphragm pumps Catalogue 2011 rev 1 General your reliable pumpchoice With experience from industrial fluid handling and pump manufacture since 1970, we know what you as a customer require
More informationDifferential pressure gauge with electrical contact type Model: P650 series
Differential pressure gauge with electrical contact type Model: P650 series Service intended The P650 series are designed to measure a differential pressure from 25 kpa to 2.0 MPa at static pressure up
More informationVehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual
1 of 5 4/7/2008 8:32 AM Home Account Contact ALLDATA Log Out Help Select Vehicle New TSBs Technician's Reference Component Search: METRO TOYOTA OK 1999 Ford Truck F 450 2WD Super Duty V10-6.8L VIN S Vehicle
More informationINSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold
LOW VAC INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold REF HIGH SPECIAL FEATURES Low battery indicator Displays 63 refrigerants Displays corresponding saturation, dew or bubble point temperature
More informationUser Manual. Single Diaphragm Dosing Pump SP-177. We set standards. Industriestrasse 56 FAX: FL-9491 Ruggell
We set standards User Manual Single Diaphragm Dosing Pump SP-177 MA-SP-177 en SAWATEC AG Tel: +423 37717 90 Industriestrasse 56 FAX:+423 37717 91 Postfach 514 info@sawatec.com FL-9491 Ruggell www.sawatec.com
More informationElectronic flushing and pressure testing unit with oil-free compressor. REMS Multi-Push EN ZVSHK 1) DVGW 2) for Professionals
Electronic flushing and pressure testing unit with oil-free compressor. REMS Multi-Push EN 806-4 ZVSHK 1) DVGW 2) for Professionals Only one device with more than 10 automatic programs for flushing, disinfection,
More informationDesoldering Tool. New. Portable Desoldering Tool. Packing List. Specifications
Desoldering Tool New Portable Desoldering Tool Nozzle included Power switch and adjustable temperature control built in the handle Use of high thermal efficiency N61 series nozzles Reduction of solder
More information1 L Rotary Vacuum Evaporator Instruction Manual
1 L Rotary Vacuum Evaporator Instruction Manual Important This manual is designed for safe and optimal performance of this unit Please read manual carefully before operating this unit Keep this manual
More informationThe DAUREX Quick Clean Pumps
DAUREX Eccentric Screw Pumps Type EDS The DAUREX Quick Clean Pumps The DAUREX eccentric screw pump belongs to the family of rotating positive displacement pumps. It combines the advantages of the low-pulse
More informationRefrigerator. Installation Guide. Free Standing Appliance
Refrigerator Guide Free Standing Appliance Untitled-3 1 2018-04-10 12:31:22 Follow these instructions carefully to prevent accidents and to ensure the proper installation of this refrigerator. WARNING
More informationTri-Tech Medical Inc.
Submittal Data Sheet Project Information Project Number Approval Features The Tri-Tech Area and Master Alarm Panel digitally displays gas pressure (1 psi increments) monitors and displays normal and alarm
More informationInstallation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08
Installation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08 GENERAL OPERATION The KAPTIV is a zero-air-loss, electronic level sensing condensate drain. By installing the KAPTIV
More informationSelf-regulating vacuum pumps. Characteristics. Ø max. vacuum air drawn in L2 model nozzle (%) Specifications. Curves: see page 9/27.
Branch-specific applications (electric vacuum and blow-off control) Description The communication between both elements, electronic vacuum switch and gripping valve control allows the consumption of compressed
More informationPressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications
Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description
More informationSERVICE MANUAL CLASSIC PLUS 14
SERVICE MANUAL CLASSIC PLUS 14 FOREWORD This manual has been published to service the MovinCool Classic Plus 14. Please use this service manual only when servicing the Classic Plus 14. DEFINITION OF TERMS
More informationCERTUS 11 / 12 EVACUATION & REFRIGERANT CHARGING EQUIPMENT FOR FLAMMABLE GASES
CERTUS 11 / 12 EVACUATION & REFRIGERANT CHARGING EQUIPMENT FOR FLAMMABLE GASES GALILEO TP PROCESS EQUIPMENT S.r.l. Via del Pantano 73 50018 Scandicci (Firenze) Italia Tel. (+39) 055 7221358 Fax (+39) 055
More informationProduct overview Suction Guns, suction machines, Vac-Blast Cleaners
Product overview Suction Guns, suction machines, Vac-Blast Cleaners micro-cleaning for your products 3300_EN_20141020_Sauggeraete_Gesamtprogramm TiS Intelligent air utilisation Compressed air passes a
More informationComplex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series
EXTERNAL GENERATOR CONTROLLER PAD ACCESSORIES Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator Series 282 Suitable for semiconductor industry such as IC chip loader or
More informationEDITION 5 R R ENGINEERS FIRST
R EDITION 5 R R ENGINEERS FIRST R Vacuforce started as an importer of European vacuum products. Our founder, originally from the UK, brought together over 20 years of vacuum applications, engineering and
More informationNT 35/1 Ap. NT 35/1 Ap, ,
NT 35/1 Ap The NT 35/1 Ap is based on the same platform as the NT 25/1 Ap, has 10 liters more container capacity and is the successor to the NT 361 Eco. TECHNICAL DATA AND EQUIPMENT NT 35/1 Ap Technical
More informationREFRIGERANT RECOVERY DEVICES AND ACCESSORIES
DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES PROMAX RECOVERY DEVICES PROMAX designs, engineers, and manufacturers the highest quality service equipment and makes it easy to use for all refrigerant handling
More informationC 9000 Polymer Quick-Acting Safety Coupler Range
C 9000 Polymer Quick-Acting Safety Coupler Range C 9000 Polymer Quick-Acting Safety Couplers ISO B Profile 9401U Page -10 9405U Page -10 9414U Page -10 9410U Page -10 9421U Page -10 9416U Page -11 9440U
More informationInstallation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified
Installation Instructions for the MicroPressure Board Mount Pressure Sensors Compact, High Accuracy, Compensated/Amplified Issue C 32333868 General Information The is a very small piezoresistive silicon
More informationCONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE
CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile
More informationSERVICE MANUAL CLASSIC PLUS 14
SERVICE MANUAL CLASSIC PLUS 14 DENSO SALES CALIFORNIA, INC. REGISTERED TO ISO 9002 FILE NO. A5537 (800) 264-9573 www.movincool.com 2000 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not
More informationSERVICE MANUAL OFFICE PRO 18
SERVICE MANUAL OFFICE PRO 18 2003 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole or in part, without the written permission of the publisher. DENSO
More informationMEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.
WARD OXYGEN Installation, Operation, and Maintenance Instructions MEGA medical electronic gas alarm MEGA WARD MEGA medical electronic gas alarm WARD POWER SUPPLY Medical Electronic Gas Alarm OXYGEN SYSTEM
More informationEL400 OPERATION MANUAL
All Titanium Body Micromotor System EL400 OPERATION MANUAL 40,000min -1 (rpm) OM-E0078E Rev.3 Please read this operation manual carefully before use and keep for future reference. Classification of equipment
More informationSERVICE MANUAL MUH-A18WV - MUH-A24WV - MUH-A30WV - E1. Wireless type Models HFC
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision A: Resistance of LEV (Expansion valve) has been modified. Power input and others have been added to SPECIFICATION. Method of check of R.V. coil has been
More informationT a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
More informationPressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight
Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight Features Representative photograph, actual product appearance may
More information