Wiring Transmitter and Detectors. mounting hole. A023a. mounting hole. A024a
|
|
- Timothy Jared Thomas
- 5 years ago
- Views:
Transcription
1 Standard type Wiring and Detectors / Standard type for DC 3-wire and DC 2-wire Detector type Number of Detector 4 detectors 44 (23) () P=28x3=84 A023a Type Code RPK-22 Material Body Aluminum die casting Gasket Neoprene rubber Protection class IP5 Terminal block for pole x 2, for Detector 8 pole x 3 Cable gland for PG9 x, for Detector PG x 4 Changeover SW Changeover NPN/PNP Switch SW2 Changeover 3-wire/2-wire Applicable cable outer diameter φ2...5mm Mounting M4 allen screw x 2 0 g Number of Detector 8 detectors 8 detectors 35 (5) 44 (95) (23) () P=x=84 5 (23) (8) 44 (23) () 5 P=28x3=84 A024a A0a Type Code RPK- RPK-23 Material Body Aluminum die casting Aluminum die casting Gasket Neoprene rubber Neoprene rubber Protection class IP5 IP5 Terminal block for pole x 2, for Detector 8 pole x 3 for pole x 2, for Detector 8 pole x 3 Cable gland for PG9 x, for Detector M8 x 8 for PG9 x, for Detector PG9 x 8 Changeover SW Changeover NPN/PNP Changeover NPN/PNP Switch SW2 Changeover 3-wire/2-wire Changeover 3-wire/2-wire Applicable cable outer diameter φ mm φ4...8mm Mounting M4 allen screw x 2 M4 allen screw x 2 0 g 0 g 8
2 RPK- RFK-3 / Standard type for DC 2-wire and Exclusive Detector type Number of Detector 8 detectors 3 40 (9) 5 (94) P=40x3=0.5 () (9) A058a.5 3 Type Code RFK-3 Material Body Aluminum die casting Gasket Neoprene rubber Protection class IP5 Terminal block for pole x, for Detector pole x Cable gland for PG9 x, for Detector PG x 8 Changeover SW --- Switch SW2 --- Applicable cable outer diameter φ2...5mm Mounting M4 allen screw x 2 0 g Exclusive sensor Other unit - These products are the terminal box for connecting and Detector. - The blank plugs are supplied with the terminal box to seal unused cable entries. - Before use, please read the instructions in user's guide attached to products. 9
3 Waterproof type Wiring and Detectors / Waterproof type for DC 3-wire and DC 2-wire Detector type Number of Detector 8 detectors 8 detectors () 8 () 50() (9) 0 (9) 50 8() (50) 4() (3) 0 x3= (0) A02-e A02_e Type Code RPK-A RPK-A Material Body Aluminum casting/machined aluminum Aluminum casting/machined aluminum Protection class IP IP Terminal block for pole x, for Detector pole x 2 for pole x, for Detector pole x 2 Cable gland for PG9 x, for Detector PG x 8 for PG9 x, for Detector M8 x 8 Changeover SW Changeover NPN/PNP Changeover NPN/PNP Switch SW2 Changeover 3-wire/2-wire Changeover 3-wire/2-wire Applicable cable outer diameter φ4...5mm φ3...5mm Mounting M5 allen screw x 2 M5 allen screw x 2,0 g,0 g Number of Detector 8 detectors 5 detectors Ø Ø depth Ø Ø depth A028 A029 (98) (98) Type Code RPK-B-02 RPK-B-03 Material Body Aluminum casting/machined aluminum Aluminum casting/machined aluminum Protection class IP IP Terminal block for pole x 2, for Detector 8 pole x 3 for 8 pole x, for Detector 5 pole x 2 Cable gland for PG9 x, for Detector PG x 8 for PG9 x, for Detector PG x Changeover SW Changeover NPN/PNP Switch SW2 Changeover 3-wire/2-wire Applicable cable outer diameter φ4...5mm φ4...5mm Mounting M5 allen screw x 2 M5 allen screw x 2,0 g,0 g
4 RPK-A098 RPK-B RFK-A098 / Waterproof type for DC 2-wire and Exclusive Detector type Number of Detector 8 detectors 8 detectors () 8 () 50() (9) 0 (9) 50 8() (50) 4() (3) 0 x3= (0) A02-e A02_e Type Code RFK-A RFK-A Material Body Aluminum casting/machined aluminum Aluminum casting/machined aluminum Protection class IP IP Terminal block for pole x, for Detector pole x for pole x, for Detector pole x Cable gland for PG9 x, for Detector PG x 8 for PG9 x, for Detector M8 x 8 Changeover SW Switch SW Applicable cable outer diameter φ4...5mm φ3...5mm Mounting M5 allen screw x 2 M5 allen screw x 2,0 g,0 g Exclusive sensor Other unit - These products are the terminal box for connecting and Detector. - The blank plugs are supplied with the terminal box to seal unused cable entries. - Before use, please read the instructions in user's guide attached to products.
5 Connector type Wiring and Detectors /Connector type for DC 3-wire and DC 2-wire Detector type Number of Detector 4 detectors 8 detectors RPK-8C0-N, RPK-8C0-P RPK-4C0-N, RPK-4C0-P M 4-pin bolt-hole spacing 0 Cable entry for bolt-hole spacing (22.) To fix with three M5 cap bolt (L mm) 2 A0c 4 5 bolt-hole spacing M 4-pin bolt-hole spacing 9 Cable entry for 5 3 To fix with three M5 cap bolt (L mm) Lid (22.) A03c Type Code DC3W/NPN RPK-4C0-N RPK-8C0-N DC3W/PNP RPK-4C0-P RPK-8C0-P LED Material Body Aluminum casting Aluminum casting Cap Machined aluminum Machined aluminum Protection class IP IP Connection pole screwless terminal block pole screwless terminal block Detector 4 pole ( M x 4 ) 4 pole ( M x 8 ) Cable gland PG9 x PG9 x Changeover switch 4-pole DIP switch for changeover of 2-wire and 3-wire detector 8 pole DIP switch for changeover of 2-wire and 3-wire detector Mounting M5 allen screw x 3 M5 allen screw x 3 0 g 500 g Number of Detector 8 Detectors Applicable RGPT-05 RGPT-4008 RGPT-90 Type Code DC3W/NPN DC3W/PNP RPK-8C0L-N RPK-8C0L-P LED Function indication/power Material Body Aluminum casting Cap Machined aluminum Gasket RPK-8C0L-N, RPK-8C0L-P (22.) Viton M 4-pin Protection class IP Connection pole screwless terminal block Detector 4 pole ( M x 8 ) Cable gland PG9 x Changeover switch Only for DC 3-wire sensors Mounting M5 allen screw x g 4 5 LED -8 (function) bolt-hole spacing LED(power) 3.4 Lid bolt-hole spacing 4 To fix with three M5 cap bolt (L mm) Cable entry for A032c Using DC 2-wire sensors - DC 2-wire sensor can be used with RPK-4C0- N/P and RPK-8C0- N/P by switching the 3-wire/2-wire changeover switch. RPK-4C0- Use transmitter : RPTA-3-PU RPTA-05-PU Detection sensor to be used DC 3-wire DC 2-wire RPK-8C0- Use transmitter : RPTA--PU RGPT series Detection sensor to be used DC 3-wire DC 2-wire Applicable Applicable 3-wire/2-wire changeover switch NPN RPK-4C0-N OFF PNP RPK-4C0-P OFF Non-polar RPK-4C0-N ON Polar RPK-4C0-P ON 3-wire/2-wire Changeover Switch NPN RPK-8C0-N OFF PNP RPK-8C0-P OFF Non-polar RPK-8C0-N ON Polar RPK-8C0-P ON
6 RPK-4C RPK-8C RFK-8C /Connector type for Exclusive proximity sensor type Number of Detector 8 detectors bolt-hole spacing M 4-pin bolt-hole spacing 9 Cable entry for 3 5 Lid (22.).4 To fix with three M5 cap bolt (L mm) A03c Type Code RXD RFK-8C0 LED --- Material Body Aluminum casting Cap Machined aluminum Gasket Viton Protection class IP Connection pole screwless terminal block Detector 4 pole ( M x 8 ) Cable gland PG9 x Changeover switch Exclusive proximity sensor RXD only Mounting M5 allen screw x g Exclusive sensor Other unit - These products are the terminal box for connecting and Detector. - The blank caps are supplied with the terminal box to seal unused s. 3
PHOTOELECTRIC AMPLIFIER SERIES
PHOTOELECTRIC AMPLIFIER SERIES Telco s photoelectric amplifier series performs as good today as it did when it first appeared almost 25 years ago. But while the simple design of this iconic product has
More informationSafety Light Curtains Area Access Control
Presence Sensing Safety Devices Description The AAC photoelectric safety switch is a single-beam, noncontact presence sensing safety device consisting of separate transmitter and receiver units. The light
More information2 Tones to select LU7
LU PATLITE s LU & LU Series signal towers deliver the advantages of superior LED technology, innovative design, and the convenience of modular assembly with only basic modular components to meet just about
More informationSOCH AUTOMATION AND POWER SOLUTION
EMERGENCY SERVICE INDUCTIVE COLOR CAPACITIVE CONTRAST METAL FACE REED SWITCH ANALOG Soch Automation And Power Solution Ware House (India) : Golden Enclives B-Block Siddeshwara Layout, Bengaluru, Karnataka-
More informationAE Liter Tank with Pump Installation Guide
English AE-301 10 Liter Tank with Pump Installation Guide Corresponding ordering part number: 900043600G Rev. 1.3 UNPACKING: Unpack carefully. Electronic components can be damaged if improperly handled
More informationBulletin 855T 70 mm Control Tower Stack Lights
Bulletin 855T 70 mm Control Tower Stack Lights Light Modules Red Flashing Incandescent (Black Housing) 855T B 10 FN 4 a b c d a b c d Housing Color Voltage Light Module Type Lens Color Code Description
More informationPos. Description Reference
TD-13 Cover 01 Tank cover including Items 2+3 400.756 02 Filter 400.754 02 Filter (after week 39/98) 400.766 03 Tank cover 400.751 04 Seal for cover 420.723 05 Clean water tank cover 530.758 06 Washer
More informationGeneral Specifications. Small size Fast 500µs response time Cable or quick-disconnect options 11 28V DC Operating Voltage Red output LED indicator
PHOTOSWITCH Photoelectric Sensors Series 7000 Description The Series 7000 is a family of compact general-purpose rectangular sensors that offer fast 500µs response times and a variety of sensing modes.
More informationLimit Switch Box YT-870/875 SERIES
Limit Switch Box YT-870/875 SERIES PRODUCT MANUAL VERSION 1.01 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 3 2. Product
More informationGeneral Specifications
General Specifications Model DM8 Vibration Type Liquid Density Meter Overview In 1967, YOKOGAWA developed the Model VD6 Vibration Type Liquid Density Meter in response to user requests for an online density
More informationpanasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers
687 Optical Touch Switch SW-1 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Conforming to OSHA / ANSI Listing MEASURE panasonic.net/id/pidsx/global
More informationOperation and Maintenance Manual
(FKER Series) Repeater Panel (FKER, FKER, FKER8) Operation and Maintenance Manual Man-9EL Issue June Index Section Page. Introduction.... Safety and mounting.... Technical specification.... Control panel
More informationLeuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001
Throughbeam photoelectric sensors Dimensioned drawing 15m 1-3 V DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in infrared light Robust metal housing with glass cover, protection
More informationNB: POTATO PEELER. Failure to do so will invalidate your warranty.
LIMITED WARRANTY All equipment which is sold under ANVIL trademark and used for commercial purposes is warranted against defects in materials and workmanship. The warranty runs for one year from the date
More informationSpare Parts List (Kits) Model Ref.:- HM35 SERIES A Spare Parts List (Kits) Issue 8 Dated 10-February-2015 Reference Drawing 09-1108-0000 Issue B Dated 07-January 2014 Drawing Ref. Part Number DESCRIPTION
More informationGeneral Specifications
PHOTOSWITCH Photoelectric Sensors Series 6000 Description Series 6000 photoelectric sensors provide reliable general purpose sensing in a compact package. Each Series 6000 sensor has a single red output
More informationBS-100 DYFI. Installation handbook. Protecting environment, life and property... P-BS100/DCE
BS-100 DYFI Protecting environment, life and property... P-BS100/DCE P-BS100/DCE/Doc/961023 2 Autronica Fire and Security AS Contents Please observe! This handbook contains installation instructions for
More informationTECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER
TECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER ULTRA ELECTRIC PASTA COOKER 1. ELECTRIC DIAGRAMS...3 1.1 PASTA COOKER...3 1.2 OPTION AUTOMATIC LIFTING...4 2. HYDRAULIC CIRCUITS...5 2.1
More informationRAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including
More informationInterface and EOL Modules 8
Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface
More informationQT50RAF Radar-Based Sensor
QT5RAF Radar-Based Sensor Radar-based, dual-zone sensors detect moving and stationary targets, ideal for collision avoidance and outdoor crane-to-crane proximity detection. Narrow beam pattern Two independent,
More informationSmall Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall
FIST-SB2-8 I N S T A L L A T I O N I N S T R U C T I O N Small Box for Cable Termination Contents 1 Introduction 1.1 Product description 2 General 2.1 Tools 2.2 Kit contents 3 Installation and pre-assembling
More informationInstallation and Operation Guide for the UPS-64C Power Supply with CometFlash
ENGINEERING COMPANY INC. ROUTE 45, WINTHROP ROAD CHESTER, CONNECTICUT 064-0684 TELEPHONE: (860) 56-9504 FAX: (860) 56-4078 Installation and Operation Guide for the UPS-64C Power Supply with CometFlash
More informationProtected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION
QUICK CONNECT SHOWER DRAIN Protected with TechCoat finish Quick Clamping Gasket And Collar For Ceramic Tile Showers Cast Iron Clamping collar securely attaches drain to drain line Speeds installation Extra
More informationQRA10... QRA53... QRA55...
7 712 QRA7 with clamp QRA10... QRA53..., QRA55... with clamp QRA2... with clamp Flame Detectors QRA2... QRA10... QRA53... QRA55... QRA73 QRA75 The UV flame detectors are designed for use with Siemens burner
More informationMaxGard. Interconnection Systems. Durability. Performance. Safety
8Russellstoll Pin and Sleeve Power Connectors Safety Different power supply ratings can t mix: 24 single-rate device polarizations ensure exact voltage, frequency and phase differentiation Safe connections:
More informationInstallation And commissioning manual. Series S Double Beam 1/16
Installation And commissioning manual Series S Double Beam 1/16 2/16 Index Main components list Pag. 4 Installation reccomendations Pag. 5 Mounting the bracket Pag. 6 Installation example Pag. 7 Positioning
More informationLonworks Damper Interface Catalogue
Lonworks Damper Interface catalogue Release: 1.9 AUGUST 2017 Lonworks Damper Interface Catalogue Two Position, Three Position & Hot Smoke Fire Damper Interface This product forms part of a life safety
More informationTubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features
BOS S8 Description Features Applications The BOS S8 is the answer for applications requiring simple part presence detection. The BOS S8 family contains the most popular models used in industry today. Manufactured
More informationDUAL OPTIC. Installation manual
DUAL OPTIC Installation manual INDEX 1 COMPONENTS Pag. 3 2 MOUNTING EXAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION EXAMPLES Pag. 6 4 CABLES AND CABLING Pag. 7 CONNECTION AND HEATING SETTING
More informationINSTRUCTION MANUAL A131 High Level Audible Warning System
Weight: 1.5kg single AC unit 2.9kg four way AC unit Marking: 3) Installation Requirements 1) Introduction The A131 high level audible warning system is an effective wide area warning alarm system and can
More informationFire Damper Interface (230V)
Always READ this document BEFORE INSTALLATION. Please Retain for future reference. This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product
More informationIP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver
IP Access Adapters Installation Guide Entrada2DMK - IP Access Adapter Kit Kit Includes: - IP Access Receiver - IP Access Transmitter I.T.E. 43KC Doc. No. IIEntrada2DMK Rev. 062015 More than just power.
More informationSmoke Fire Damper Interface (230V)
Always READ this document BEFORE INSTALLATION. Please Retain for future reference. This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product
More informationSmoke Damper Interface (230V)
Always READ this document BEFORE INSTALLATION. Please Retain for future reference. This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product
More informationProcess Automation. Sensors and Systems: Level Sensors Level Detectors Overfill Prevention. Process Automation. Accuracy.
Process Automation Process Automation Accuracy Level Sensors Level Detectors Overfill Prevention Flexible Sensors and Systems: www.fafnir.com Reliable LS 300 and LS 500 Protect Your Most Valuable Assets
More informationINSTRUCTION MANUAL TABLE OF CONTENTS
INSTRUCTION MANUAL WIDE RANGE SPEAKER CS-154BS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION AND FEATURES... 3 3. IMPEDANCE CHANGE... 4 4. WIRING 4.1. When No Bridge Connection is
More informationINERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)
FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries
More informationSafety control unit 471 M41 H31. for 4 to 32 sensors, with safety and control outputs. Use. Models. + PLe according to EN ISO
Safety control unit for 4 to 32 sensors, with safety and control outputs 471 M41 H31 + PLe according to EN ISO 13849-1 + Four safety outputs (two separate safety circuits each with two safety outputs)
More informationVACUUM PUMP Micro Cartridge Pump
Pump Max. vacuum level : -85 kpa Max. flow rate : 6.5 NI/min Supply air pressure :.~.6 bar, max 7bar (43.5~87 psi, max 0.5 psi) Air consumption : 6.8~0.6 NI/min Supply air type : Dry compressed air Working
More informationHeimdall Radar Traffic Detector
Heimdall Radar Traffic Detector Traffic Data Detector Installation Guide Document Authorisation Role Name Function Signed Prepared by: R. Martin Project Support Manager Reviewed by: A. Rhodes Lead Product
More informationMINI-EYE MINI-EYE. 2 General Application Photoelectric Sensors. General Purpose Photoelectric Sensor
2 General Application Photoelectric Sensors General Purpose Photoelectric Sensor 2-43 General Application Photoelectric Sensors 2 The TRI-TRONICS photoelectric sensors are designed to be low in cost and
More informationMINI-EYE MINI-EYE. 2 General Application Photoelectric Sensors. Miniature Sensor
2 General Application Photoelectric Sensors Miniature Sensor 2-47 General Application Photoelectric Sensors 2 The TRI-TRONICS sensors are designed to be low in cost and high in value. The sensors are waterproof
More informationNATELA 5. Based on 30 PRODUCT SPECIFICATIONS PRODUCT FEATURES PHOTOMETRIC DATA LIGHT DISTANCE CURVE 22W LINEAR WALL WASHER
NATELA 5 22W LINEAR WALL WASHER This 22W linear wall washers reveals superior craftsmanship and a slim design, perfect for highlighting building facades and landscape walls (Also Available in RGB). PRODUCT
More informationTHINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS
THINLINE 2.0 - TL2 SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed
More informationInstallation, Operating and Servicing Instructions
Installation, Operating and Servicing Instructions Wall Mounted Water Boiler WMB3F/B,WMB3F/W Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number: Dealer:
More informationHeimdall Radar Traffic Detector
Heimdall Radar Traffic Detector Standard VA Detector Installation Guide Document Authorisation Role Name Function Signed Prepared by: R. Martin Project Support Manager Reviewed by: A. Rhodes Lead Product
More informationTemperature Measurement Transmitters for field mounting
Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted
More information10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable
R Label Detection Sensor E3S-CD68/63 Detect Labels Regardless of Label Color or Luster, Bottle Color or Clarity H High-performance circuitry detects wide variety of labels on clear and colored bottles
More informationFIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module
FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required
More informationHeimdall Radar Traffic Detector
Heimdall Radar Traffic Detector Selectable Speed Detector Installation Guide Document Authorisation Role Name Function Signed Prepared by: R. Martin Project Support Manager Reviewed by: A. Rhodes Lead
More informationMULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI
MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI Intermediate modules are non-independent multi-stage and multi-function vacuum generators to be assembled to the generators
More informationGeneral Purpose Photoelectric Sensor
EZ-EYE 2 General Application Photoelectric Sensors General Purpose Photoelectric Sensor www.ttco.com 800-237-0946 2-37 General Application Photoelectric Sensors 2 EZ-EYE The EZ-EYE miniature photoelectric
More informationHeimdall Radar Traffic Detector
Heimdall Radar Traffic Detector Single Lane VA Detector Installation Guide Document Authorisation Role Name Function Signed Prepared by: R. Martin Project Support Manager Reviewed by: A. Rhodes Lead Product
More informationGeneral Specifications
eneral Specifications DO70 Optical Dissolved Oxygen Sensor EERA DO70 optical dissolved oxygen sensor is designed for using in water treatment plants such as sewage treatment works and effluent activated
More informationSCC 201E Valid as of E21SE0404 up to E21SE... SCC 201E
Electrical unit Voltage 3 NAC 400V 50-60Hz 1 1 Control panel 2 2 Electrical installation 3 3 Clima Plus 4 4 Steam generator, Bypass 5 5 Hot air heating 6 6 Motor and fan wheel 7 7 Interior cabinet 8 8
More informationAPS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features
Sensor INFORMATI Series Features Polycarbonate Resin, -wire/-wire DC System - Front Surface / Upper Surface detection - s of different frequency are available for adjacent installation. - Conformity with
More informationRogue 4 specializes in extreme output high performance LED lighting.
www.rogue-4.com Rogue 4 specializes in extreme output high performance LED lighting. Built for the rugged outdoor environment and built to last. Offering advanced technologies like thermal regulation and
More informationWorcester Controls PS/PM Series UltraSwitch. Switchbox
TM Worcester Controls PS/PM Series UltraSwitch Switchbox Simple Reliable Rugged The PS/PM Series UltraSwitch TM provides accurate and reliable position signaling in harsh corrosive environments. The engineered
More informationSeries PHOTOSWITCH Photoelectric Sensors. Standard and Timing. Description. Supplied Accessories
PHOTOSWITCH Photoelectric Sensors Series 9000 Description Series 9000 photoelectric sensors are designed to perform in many harsh environments. They are well-sealed, with critical components epoxied in
More informationIR FLAME DETECTOR RIV-601/F
IR FLAME DETECTOR EN 54-10 class 2 VdS approval G 205044 application manual CONTROL LOGIC rev. 4 DEC07 MAFE DEC07 IR FLAME DETECTORS SUMMARY Page general notions...3 description...4. Electrical and general
More informationBeck. The differential pressure transmitter for air
Beck. The differential pressure transmitter for air Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure,
More informationnew new Industrial plugs and sockets
Industrial plugs and sockets 213.1633 213.3236 221.1633 226.1636 New Optima series 16A-32A-63A-125A insulation voltage : 690V AC protection degree : IP44 and IP67 operating temperature : -25ºC to 40ºC
More informationCompact Catalog Solar
Compact Catalog Solar Company High-performance and competent di-soric has successfully been involved in the application, support, development and production of standard and special sensors for industrial
More informationSTRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED
SXP30 Series STRUCTURED LIGHT Projector product introduction The SXP30 Series Projector Light offers the most intense projected pattern offered from an LED. The 9mm² die size emits 9x the intensity as
More informationMobrey ultrasonic Liquid level detection systems
Product data sheet IP201, Rev AA February 2009 Level Mobrey ultrasonic Liquid level detection systems Description Ultrasonic liquid level switches are used in industrial processes, to detect high or low
More informationR-GAGE QT50R-AF2W Sensor
Radar-Based Dual-Zone Narrow-Beam Sensors for Detection of Moving and Stationary Targets Models Features Fourth generation FMCW (true-presence) radar detects moving and stationary objects Narrow beam pattern
More informationVENTURI AIR SPRAYERS. Parts Manual For Models P50N1-400-G15 & P50S1-400-G Gallon Capacity. Form: P50N1_P50S1-G15Book.indd
VENTURI AIR SPRAYERS Parts Manual For Models P50N1-400-G15 & P50S1-400-G15 100 Gallon Capacity Form: P50N1_P50S1-G15Book.indd June 2013 TABLE OF CONTENTS SECTION DESCRIPTION... PAGE 1 Introduction...1
More information110 lm w STANDARD SERIES
ASD LED Bullet Flood light uses the latest in solid state lighting technology for high efficiency, long life and low maintenance. It s good for facade, landscape and sign lighting applications. Our LED
More information2 General Application Photoelectric Sensors
MITY EYE General Purpose Photoelectric Sensor 2 General Application Photoelectric Sensors 2-49 General Application Photoelectric Sensors 2 MITY EYE Designed for Trouble-Free Operation Many design features
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation, Inc. 1201 South 2 nd Street Milwaukee, WI 53204 USA EU Declaration of Conformity RightSight Photoelectric Sensors Name and address of
More informationWIDE RANGE SPEAKER INSTRUCTION MANUAL TABLE OF CONTENTS
INSTRUCTION MANUAL WIDE RANGE SPEAKER CS-64BS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION AND FEATURES... 3 3. IMPEDANCE CHANGE... 3 4. WIRING 4.1. When No Bridge Connection is
More informationSPACEMOTION SERIES SMM 01
SPACEMOTION SERIES SMM 01 Description K-Band motion and direction detection Max sensing range: 3 metres Adjustable sensing field range Adjustable slow speed zone Selectable background suppression Selectable
More informationPROFIBUS-PA Display RID 261 PROFIBUS-PA
Technical Information TI 071R/09/en Mat.-Nr.: 510 01194 PROFIBUS-PA Display RID 261 PROFIBUS-PA Display of process values and set point alarms on PROFIBUS-PA systems R Applications Direct connection to
More information2 General Application Photoelectric Sensors
2 General Application Photoelectric Sensors General Purpose Photoelectric Sensor 2-49 General Application Photoelectric Sensors 2 Designed for Trouble-Free Operation Many design features have been incorporated
More informationQRA10... QRA53... QRA55...
7 712 QRA7 with clamp QRA10... QRA53..., QRA55... with clamp QRA2... with clamp Flame Detectors QRA2... QRA10... QRA53... QRA55... QRA73 QRA75 The UV flame detectors are designed for use with Siemens burner
More informationDurafet Non-Glass ph Electrodes Specifications
Durafet Non-Glass ph Electrodes Specifications 70-82-03-50 February 2004 Description Honeywell defines state-of-the-art ph measurement with the Durafet ph electrode, an industrial, non-glass, unbreakable,
More informationINSTALLATION INSTRUCTIONS. Anti Knocking System, AKR 3. Document no.: A SW version:
INSTALLATION INSTRUCTIONS Anti Knocking System, AKR 3 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel: +45 9614 9614 Fax: +45 9614 9615 info@deifcom wwwdeifcom Document no: 4189340792A SW version: 1 General
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305
DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationEN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures
EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures HDL-3-EX* Complete and ready to install Heat Detector with Ex-certified Box, Cable gland and wiring
More informationInstallation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II
Installation and application Leakage detectors, CLS/FLS/FLS/MiniCAS II INTRODUCTION A number of condition monitoring sensors are available for the ITT FLYGT pump range. Thermal switches for stator over
More informationSPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001
ISO-14001 ISO-9001 SPECIFICATION SHEET ORGANIC POLLUTION MONITOR Model: OPM-410A The Model OPM-410A monitors organic pollution in water from industrial effluent, rivers etc.. The design and construction
More informationINFRARED MODULATED BARRIERS
INFRARED MODULATED BARRIERS riello elettronica group INFRARED BARRIERS WITH ADJUSTABLE LENSES FULL FULL SYNCRO POWER SUPPLY 12/24 Vac-dc MAXIMUM RANGE UNDER IN CONDITIONS 15 METRES CONFORMS TO THE SAFETY
More informationDEMA 830 Laundry Master TM Installation Instructions
I-656 Pg. 1 of 9 SYSTEM OVERVIEW The DEMA 830 Laundry Master is designed for long reliable use with simplicity in mind for both the installer and user. The system is based on the reliable DEMA peristaltic
More informationConductive Leakage detectors of the Leckstar range
Conductive Leakage detectors of the Leckstar range with electrode and relay Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466 Lambrecht (Germany) Tel. +49 6325 188-01 Fax +49 6325 6396 www.jola-info.de
More informationLEVEL MONITOR WITH ANALOG AND HIGH / LOW ALARM OUTPUTS. DATASHEET F170 - LEVEL MONITOR
LEVEL MONITOR WITH ANALOG AND HIGH / LOW ALARM OUTPUTS. DATASHEET LEVEL MONITOR Features Displays level and percentage filled. 4 alarm values can be entered: lowlow, low, high and highhigh level alarm.
More informationGAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for HUALING
GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for HUALING HUALING heating elements/thermostats heating elements heating elements for fryers 2 hole
More informationDBS721, DBS729 Sounder interbase, Sounder beacon interbase
DBS721, DBS729 Sounder interbase, Sounder beacon interbase For the automatic addressable detector bus C-NET Cerberus PRO Sounder interbase DBS721 and sounder beacon interbase DBS729 11 selectable tones,
More informationSINGLE MONITORED INPUT UNIT BN-303
SINGLE MONITORED INPUT UNIT BN-303 Interactive fire detection system Product Datasheet Features Interactive For interfacing switches and 3rd party detectors with relay outputs to Autronica s interactive
More informationMODELS 304GC, 304GCX, 314GC, and 314GCX
2562109A REV. A1 0317 Printed in U.S.A. MODELS 304GC, 304GCX, 314GC, and 314GCX INSTALLATION AND SERVICE INSTRUCTIONS FOR SELECTONE Limited Warranty This product is subject to and covered by a limited
More informationDIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES
DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the
More informationQRA10... QRA53... QRA55...
7 712 QRA7 with clamp QRA10... QRA53..., QRA55... with clamp QRA2... with clamp Flame Detectors QRA2... QRA10... QRA53... QRA55... QRA73 QRA75 The UV flame detectors are designed for use with Siemens burner
More informationBadger Universal Control Head
Badger Universal Control Head P/N: 60-120099-002 FEATURES For Use in: Range Guard Commercial Cooking Fire Suppression Systems Industry Guard Industrial Fire Suppression Systems Pneumatic Release of up
More informationRetroreflective sensor with polarization filter
Dimensions 45 49 Receiver 23 27 74 56 Emitter 92 23 6 x 9 slots External thread (M30 x 1.5) 10 25 32 M12 x 1 Sens Delay IMER Model Number Retroreflective sensor with 4-pin, M12 x 1 connector Electrical
More informationTBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22
Hazardous Area Electrical Equipment Made TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBSF/CBSF Information Page
More informationGENERAL APPLICATION SENSORS NEW! MINI-EYE. General Application Photoelectric Sensors. Small, Rugged and Powerful... yet Low in Price MINI-EYE 2-55
GENERAL APPLICATION SENSORS NEW! Small, Rugged and Powerful... yet Low in Price -55 Miniature Sensor Small, Rugged and Powerful... yet Low in Price The TRI-TRONICS photoelectric sensors are designed to
More informationFACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES
FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES SENSE WITH SIMPLICITY AND CONFIDENCE ADVANTAGE OF GANG-MOUNTING METHOD SU18-16 POTENTIOMETER SU18
More informationWall-mount box mini. Specifications
Wall-mount box mini DATA SHEET DB4124-E Issue C Page 1 of 1 For indoor use. For termination of optical connectors. Prepared for splicing of pigtails (splice holder included). Adapter plates exists for
More informationOperating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA
Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4
More informationUNIVERSAL COMPACT SENSORS
HIGH-PERFORMANCE SENSORS UNIVERSAL COMPACT SENSORS High-resolution sensors with LED or Laser emission Background suppression models ranging from 30 cm to m Polarised retroreflex with operating distance
More information