SPACEMOTION SERIES SMM 01
|
|
- Cuthbert Wilkinson
- 5 years ago
- Views:
Transcription
1 SPACEMOTION SERIES SMM 01 Description K-Band motion and direction detection Max sensing range: 3 metres Adjustable sensing field range Adjustable slow speed zone Selectable background suppression Selectable direction sensitive detection Adjustable off time delay V dc or 24 V ac/dc supply voltage Power and output indicators Solid state relay output monitor function (Sniffer) Compact IP67 housing design Especially designed for escalator and moving-walk applications The SpaceMotion series is a compact Doppler radar sensor that detects motion in the detection area using the latest in microwave technology and a powerful microprocessor. The compact design allows it to be installed in space limited locations, where traditional motion sensors cannot be installed. The microwave technology allows the sensor to be mounted behind plastic constructions for out-of-sight installations. The Doppler radar sensor detects objects that are in motion towards or away from the sensor. People passing the sensor perpendicular (i.e. with no intention of entering an escalator) will have no or very low speed relative to the sensor such motion can remain undetected. The detection field is divided into two parts; low-speed zone and highspeed zone. The part of the field closest to the sensor is the low-speed zone where low speed motion is detected. This is intended to detect people in a multi-storey building that are moving from one escalator to the next making a semi-circular movement/turn i.e. perpendicular to the sensor and with a relatively low speed. The extension of the low speed zone relative to the high speed zone can be adjusted from 0 100% of the total range. Total range is also adjustable. The sensor also includes a background suppression feature which allows the sensor to ignore all constant movements of minor objects (either directly or indirectly detected through reflections) e.g. handrails. Technical Data ac/dc V dc / 24 V ac Supply voltage dc V dc Voltage ripple +/ 15 % Solid state 100 ma monitor function Yes (dc model only) Reverse polarity protected Yes Short circuit protected Yes Power consumption Max 600 mw Technology Microwave K-Band, GHz Horizontal field +/ 40 Vertical field +/ 16 Power on indicator Green LED indicator Yellow LED 0-3 m, potentiometer adjustable 0-10 sec, potentiometer adjustable Background suppression Selectable Low speed zone extension Potentiometer adjustable Housing dimension (w x h x d) 50 x 50 x 30 mm Housing material Plastic, PVC Ø 4 mm 4 x 0,14 mm 2 Environmental Data Vibration Hz, 0,5 mm Shock 30 g Temperature, operation 20 to +55 C Temperature, storage 40 to +80 C Sealing class IP 67 Approvals a SPACEMOTION SERIES I 1
2 SMM 01 SPACEMOTION SERIES Available Types Type Power Supply Housing 5 m cable (w x h x d) Order Reference V dc 24 V ac / V dc 50 x 50 x 30 Low SMM 01 L S50P 5 Solid SMM 01 H S50P 5 State NC Low Relay SMM 01 L S50P 5 SMM 01 H S50P m s Cable Supply + Supply Wiring Diagrams Sniffer Sniffer (load as NPN) (load as PNP) (load as NPN) (load as PNP) 2 I SPACEMOTION SERIES
3 SPACEMOTION SERIES SMM 01 Dimensions and Descriptions 50,8 29,5 13, ,9 50,8 50,8 49,8 27,5 5,5 Ø 4 Direction sensitive on Direction sensitive off Signal summation on Signal summation off Background suppression on Background suppression off LED indicators speed zone (Units in mm) Sensing Characteristics Sensitivity (normalised) Degrees Elevation Azimuth Azimuth Elevation SPACEMOTION SERIES I 3
4 SMM 01 SPACEMOTION SERIES Applications ESCALATOR Pedestrian detection Telco reserves the right to change specifications without notice. 4 I SPACEMOTION SERIES
5 SMM 01 USER MANUAL Spacemotion Series EN tel Product Data Electrical Data Supply voltage (*) V dc or 24V ac Power consumption Max 600 mw : Solidstate 100mA / 30 DC (*) Depends on type, 10-30V dc types have build-in output monitoring function (sniffer). Steps Check the power supply complies with electrical data. Make sure power is off. Connect all wires according to wiring diagrams. Turn on power. Wires/Pins Cable Supply + Pin 1 / 4 pin, M12 plug, male Environmental Data Temperature, operation -20 to +55 C Sealing class IP 67 Supply Pin 3 / (load) Pin 4 / Sensing 0-3m Horizontal field +/-40 degrees Vertical field +/-16 degrees Indicators Green LED Power On Yellow LED status. (See output logic) Blink for output alarm (*) (*) For types with build-in output monitoring function. Pin 2 / Adjustments Mechanical adjustment Sensor plug Notice that the sensing field is not symmetrical. The sensing field is in the direction perpendicular to front of the housing. The sensing field is narrow in the directions where the cable is inserted and wide in the direction orthogonal to the cable insertion. Notice that there are two different types of the sensor marked with L and H. Whenever two sensors are used to detect the same objects, use one of each type, to avoid risk of interference. Available Models Type Model Illustration SMM 01 L S50P SMM 01 H S50P SMM 01 L S50P SMM 01 L S50P Supply Voltage V dc 24 V ac / V dc Low Low Solid State Relay NC Sensing 0 3 m Acces to potentiometers and LED s The sensor has to be disassembled in order to get access to potentiometers, LED s and switch. The enclosure can be taken apart if the 4 top screws are removed, and the PCB-board will be visible as shown in figure 1. Potentiometers (*) Extension of high-speed zone adjustment Within the sensing range, there are two zones; a high speed zone and a low speed zone. In the low speed zone which is close to the sensor, objects with speeds down to app. 20 cm/s will be detected. This is advantageous in order to detect crossing traffic close to the escalator, for instance when traffic is passing from one escalator to the next escalator in a multi-storey building. In the high speed zone only objects with speed larger than 0.4 m/s = 1.5 km/h will be detected. This will to reduce cross-traffic detection, but on the other hand still detect motion towards the sensor. (*) See figure 1. For radar sensor it is the speed towards the sensor that matters. (or more precisely the magnitude of the velocity projected on the line between the sensor and the object). Increasing the potentiometer will increase the fraction of the high speed zone and reduce the size of the low speed zone. Delay on de-activation of output can be adjusted between 0 s and 10 s Dip switches (*) 1 Background suppression on/off. Minor signals from constant signal contributors as for instance fluorescent light tubes and constantly moving parts as handrails on escalators, that may lead to unwanted detection are suppressed. Disable the function if it is not needed. Wiring diagrams The sensor has a solid-state relay output, and for the dc-versions also with an integrated output monitor Sniffer. Connect as below to ensure correct function of the sniffer. If faulty connected or failure is found the output is de-energised and the yellow LED will start blinking. Ensure correct connection and repower the sensor to escape the fault mode. If there is no Sniffer, i.e. the ac/dc-versions, there are no special requirements for connection of the opto-coupled solid state relay output. Configuration of NPN output 2 Signal summation on/off. If signal summation is on, multiple objects with different speed are all contributing to detection. Can provide more consistent detection of for instance legs, because these consist of different minor parts moving with different velocity relative to the sensor. Turn signal summation off if the range is larger and the sensor is directed towards the body, because the sensor then will have less sensitivity to background traffic. 3 (**) Direction sensitive on/off. If on the sensor will only detect objects moving towards the sensor. If off the sensor will detect both objects moving towards and away from the sensor. (*) See figure 1 (**) Only present for direction sensitive types Logic Detection indicator Moving objects present OFF OFF No objects or non-moving objects ON ON Configuration of PNP output Electrical adjustment Turn potentiometer fully clockwise for maximum range. Turn Off-delay fully anti clock wise to remove off-delay, for instant response. Turn high speed zone fully anti clock wise to remove high speed zone, for maximum motion sensitivity. This setting corresponds to the factory setting. Check if the sensing distance is adequate, but not excessive. Turn the potentiometer anti clockwise in steps until suitable range is obtained. With the speed zone set to zero (fully anti clock wise) the sensor will detect all motions down to 20 cm/s in the full sensing range. Crossing traffic will therefore be detected in the entire sensing range. Turn the speed zone potentiometer clockwise in steps in order to make the part of the sensing zone which is distant from the sensor to a high speed zone. Check whether crossing traffic is detected. 4 Finally increase the Off-delay if needed by the control system. Website: Warning V 1.3 Part Number: info@telcosensors.com April 2017 edition This product is not a safety system and must not be used as such.! It is not designed for personnel safety applications, and must not be used Made in Denmark as a stand alone personnel safety system. Telco A/S reserves the right to make changes without prior notice
PHOTOELECTRIC AMPLIFIER SERIES
PHOTOELECTRIC AMPLIFIER SERIES Telco s photoelectric amplifier series performs as good today as it did when it first appeared almost 25 years ago. But while the simple design of this iconic product has
More informationDimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor
Dimensions ø.7 9.5 6.5 8.5 ø.7 65 57 Window for LED display Model Number Radar sensor Features Industrial gate opener with the ability to differentiate between people and vehicles Extra-wide detection
More informationDimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.
Dimensions ø.7 9.5 6.5 8.5 ø.7 65 57 Window for LED display Model Number Radar sensor Features Industrial gate opener with the ability to differentiate between people and vehicles Extra-wide detection
More informationMD12-1 Vehicle Loop Detector
MD12-1 Vehicle Loop Detector Features Supply 12VDC Adjustable sensitivity (16 levels via a trimpot) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry
More informationDimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor
Dimensions 139.6 103 99.6 46 130.7 Electrical connection Model Number Radar sensor Features Degree of protection IP67 Differentiated detection of people and vehicles, each with one output relay Cross-traffic
More informationInstruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn
Instruction manual Digital Radar Motion Detector with Infrared Remote Control MWD BF FEIG ELECTRIC GmbH Lange Straße 4 35781 Weilburg/Lahn 22.08.02 MWD BF Instruction manual General Copyright 2002 by FEIG
More informationDHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS
NOTE: Set up for this sensor should be performed by an AAADM-certified installer. Section 1 General Description The DHR3 is a combination microwave/infrared sensor providing both motion detection and presence
More informationDimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor
Dimensions 139.6 103 99.6 46 130.7 Electrical connection Model Number Radar sensor Features Degree of protection IP67 Differentiated detection of people and vehicles, each with one output relay Cross-traffic
More information0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide
Instruction Manual EESIFLO EASZ-12 Doppler Flow Switch 55 120 0-2 m/s Lo Alarm 0-6 m/s Hi Alarm 120 Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide Doppler Flow Switch - EASZ-12 Introduction
More informationpanasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers
687 Optical Touch Switch SW-1 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Conforming to OSHA / ANSI Listing MEASURE panasonic.net/id/pidsx/global
More informationPSC-ID-x-CM Series Ceiling Mount Occupancy Sensor
TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor
More informationACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.
ACTIV8 ONE OFF USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR 1 Description Cover 2 nd Radar Antenna Radar motion sensor Push-Buttons IR-Presence sensor Radar Antenna clip IR-Prism
More informationFlowJam Bulk Flow Detection
EN Operating Instructions FlowJam Bulk Flow Detection SWR engineering Messtechnik GmbH CONTENTS Page 1. Function............................................................................. 3 2. Safety..............................................................................
More informationXUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8
Characteristics photo-electric sensor - XUM - multi - Sn 0..10m - 12..24VDC - M8 Main Range of product Series name Electronic sensor type Sensor name Sensor design Detection system Material Type of output
More informationGeneral Specifications
PHOTOSWITCH Photoelectric Sensors Series 6000 Description Series 6000 photoelectric sensors provide reliable general purpose sensing in a compact package. Each Series 6000 sensor has a single red output
More informationUNIVERSAL COMPACT SENSORS
HIGH-PERFORMANCE SENSORS UNIVERSAL COMPACT SENSORS High-resolution sensors with LED or Laser emission Background suppression models ranging from 30 cm to m Polarised retroreflex with operating distance
More informationOperating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P
Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P with integrated pressure sensor - Art-No.: 30588 / mit eingebautem Drucksensor - Art-Nr.: 30588 GB DE Operating instructions DVC-P 2-13
More informationHR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor
Section 1 General Description The is a microwave motion sensor for activating automatic industrial doors. Features include a speed selectable switch that makes the unit capable of detecting pedestrians
More informationInstallation, Operating and Maintenance Manual
STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS
More informationTABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation
DETECT 1000 DOPPLER DETECTION INSTALLATION AND OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation
More informationXUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12
Characteristics photo-electric sensor - XUX - multi - Sn 0..40m - 12..24VDC - M12 Complementary Enclosure material Lens material Maximum sensing distance Output type Add on output Status LED [Us] rated
More informationOperating Instructions. Digital Radar Motion Detector With Infrared Remote Control MWD BF. Hörmann KG Verkaufsgesellschaft
Operating Instructions Digital Radar Motion Detector With Infrared Remote Control MWD BF Hörmann KG Verkaufsgesellschaft page 2 of 16 operating instructions MWD BF page 3 of 16 operating instructions MWD
More informationTubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features
BOS S8 Description Features Applications The BOS S8 is the answer for applications requiring simple part presence detection. The BOS S8 family contains the most popular models used in industry today. Manufactured
More informationRetroreflective sensor with polarization filter
Dimensions 45 49 Receiver 27 74 Emitter 92 56 23 6 x 9 slots S 23 25 32 Internal thread (1/2-14 NP) External thread (M30 x 1.5) ø 6 mm Cable 10 Model Number Retroreflective sensor with fixed cable Features
More informationPRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.
Ø297mm Packing list in Ceiling Mount Lamp LEDS 96PCS Φ6 Wall plug 3x30 Screw Φ3 Sealing ring 4x12 Y type Stainless Screw Quantity 1X 4X 4X 3X 3X PRODUCT INFORMATION 98.5mm Ideal for energy saving this
More informationDEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual
Technical Manual Type EC-2 Engine Control Unit 4189340232D DEIF A/S Technical Manual DEIF A/S Tel.: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fax: (+45) 9614 9615 Denmark E-mail: deif@deif.com Contents
More informationSENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -
The sensor is designed for frequent washdowns with a corrosion-resistant AISI316L stainless steel case IP69K rated, compliant to test environments like indicated by Diversey and Ecolab. However, all models
More informationMD12-2 Vehicle Loop Detector
MD12-2 Vehicle Loop Detector Features Supply 12VDC Adjustable sensitivity (8 levels via dip switch) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry
More informationRetroreflective sensor with polarization filter
Dimensions 45 49 Receiver 23 27 74 56 Emitter 92 23 6 x 9 slots External thread (M30 x 1.5) 10 25 32 M12 x 1 Sens Delay IMER Model Number Retroreflective sensor with 4-pin, M12 x 1 connector Electrical
More informationHX-40/40AM/ 40DAM. High Mount Outdoor Detector
HX-40 PIRs standard model HX-40AM HX-40 with anti-masking HX-40DAM HX-40AM with micro-wave 3.0 m high mount detection area (.0 m) Unique pyro element Intelligent AND logic High Mount Outdoor Detector HX-40/40AM/
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationLaser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing
Dimensioned drawing en 1-214/7 5122143 3 Hz.5 26m We reserve the right to make changes DS_PRKL2566P_en_5122143.fm 1-3 V D 2 LS Laser class 1 acc. to EN 6825-1 Polarized retro-reflective photoelectric sensor
More informationISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product
More informationResidual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)
Residual current monitor RCM470LY/RCM475LY for TN and TT systems (AC and pulsating DC currents) TDB401003en/03.2010 Residual current monitor RCM470LY Residual current monitor for TN and TT systems (AC
More informationExercise 1. Introduction to Sensors EXERCISE OBJECTIVE
Exercise 1 Introduction to Sensors EXERCISE OBJECTIVE When you have completed this exercise, you will be introduced to photoelectric, capacitive and inductive sensors; You will also be introduced to the
More informationLeuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001
Throughbeam photoelectric sensors Dimensioned drawing 15m 1-3 V DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in infrared light Robust metal housing with glass cover, protection
More informationABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual
ABLOY DA460 SWING DOOR OPERATOR Installation and commissioning manual APPROVALS / STANDARDS 73/23/EEC (Low Voltage directive) 93/68/EEC (Low Voltage directive) 89/336/EEC (EMC directive) Statement of fire
More informationREA 105 Arc Protection Module. Operator s Manual
REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5
More informationMODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL
TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationBIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR
BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR DESCRIPTI & FEATURES With High Frequency Occupancy On/ Off Sensor ; HF System: 5.8GHz±75MHz, ISM wave band Sensor Power consumption : 0.5W(- standby);
More informationELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description
Loop Detector is used to detect metal objects such as motor vehicles, motor bikes or trucks. ELSEMA Features Wide supply range: 12.0 to 24 Volts DC 16.0 to 24 Volts AC Selectable sensitivity Pulse or Presence
More informationSnifter. User Manual. Distributor
Snifter User Manual Distributor Version 1.3 08/09/2009 1 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 3 1.3 How does it work?... 3 2. INSTALLATION... 4 2.1 Selecting the
More informationEnglish. Italiano. Português. Françias. Español
DT AM Grade 3 Español Françias Português Italiano English High Ceiling Mount Detector Installation Guide English DT AM Grade 3 High Ceiling Mount Detector Installation Guide General Description The Industrial
More informationCarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R
O P E R A T I N G I N S T R U C T I O N S CarSense 303 TM M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales
More informationPNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel
PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum
More informationTLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.
Installation and Operation Manual RoHS CEDES AG is certified according to ISO 9001: 2008 English Pages 2-12 111 189 130208 V 1.0 Contents 1. About this manual 2 1.1 Measurements 2 1.2 Related documents
More informationSP-1000X. Panic Device Power Controller Installation Guide. Rev
TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current
More informationEx SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...
14 Ex SOLENOID / ALARM DRIVER PRepower 5203B Table of contents Warnings... 16 Safety instructions... 17 Declaration of Conformity... 19 How to dismantle SYSTEM 5000... 20 Application... 21 Technical characteristics...
More informationFlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH
EN FlowJam S Ex Operating Instructions Bulk Flow Detection SWR engineering Messtechnik GmbH CONTENTS Page 1. Function.......................................................................... 3 2. Safety..............................................................................
More informationAO Annunciator Module
General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,
More informationU L T R A S O N I C G A S L E A K D E T E C T O R
U L T R A S O N I C G A S L E A K D E T E C T O R GasSonic Surveyor ultrasonic gas leak detector APPLICATIONS (EXAMPLES) Offshore and Onshore Oil and Gas Installations Petrochemical Processing Plants Gas
More informationUltrasonic Proximity Sensor
Ultrasonic Proximity Sensor Compact, Column-shaped Sensor Capable of Sensing Range Setting Ensures the stable detection of a variety of objects regardless of the color, transparency, or material (metallic
More informationDESIGN EASY ADJUSTMENT
Door Sensor OM-105C/106C The Optex OM-105C and OM-106C microwave sensors are especially designed to increase the comfort on opening all types of automa - tic doors. The Optex microwaves provide fast detection
More informationAPM110 LOW AIR VELOCITY ALARM
home APM0 LOW AIR VELOCITY ALARM Ultra low velocity measurement Output as linear Velocity or Air volume Excellent repeatability Excellent Zero Stability Climate chamber compensated Long term span stability
More informationCarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R
O P E R A T I N G I N S T R U C T I O N S CarSense 303 TM M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales
More informationGAS SUPRESSION CONTROL PANEL:
GAS SUPRESSION CONTROL PANEL: MODEL NAME: COMPANY: DELTA 437/2, Main Road, Mandwali Fazalpur, Delhi-110092 Page 1 ABOUT THE PRODUCT ASES is very proud of to introduce DELTA the completely digital microprocessor
More informationD-TEK -MS Vehicle Loop Detector. Operating Instructions
D-TEK -MS Vehicle Loop Detector Operating Instructions We have designed the new D-TEK vehicle loop detector with the following objectives in mind: 1. Compact package to allow easy installation into small
More informationConstant voltage 3-phase rectifier.
11750a Constant voltage 3-phase rectifier. Page 1 of 11 11750a Mechanical assembly The rectifier is assembled in a cabinet intended for indoor wall mounting. The cabinet has ventilation holes on both sides
More informationSENSA MRE DDM MR
96239831 SENSA MRE DDM MR Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring and fixing 3 4 Programming 6 5 Wiring diagrams 8 6 Detection pattern diagrams
More informationQT50RAF Radar-Based Sensor
QT5RAF Radar-Based Sensor Radar-based, dual-zone sensors detect moving and stationary targets, ideal for collision avoidance and outdoor crane-to-crane proximity detection. Narrow beam pattern Two independent,
More informationDS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector
DS970-BEL EN Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector DS970-BEL Installation Instructions.0 Installation Considerations.0 Installation Considerations Not suitable
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationVibracon LVL-A* Level limit switch for liquids, compact design
Technical Information TI 364O/98/en/.07 8905 /07 0 Vibracon LVL-A* Level limit switch for liquids, compact design Application The Vibracon LVL-A* is a level limit switch for all kinds of fluids and is
More informationPTE0705 Electric Fence Monitor
PTE0705 Electric Fence Monitor The JVA logo is a registered trademark of JVA Technologies. JVA Technologies. TABLE OF CONTENTS DESCRIPTION... 2 QUICK START GUIDE... 3 FEATURES... 4 EXPLANATION OF TERMS...
More informationDoor Release Power Supply
www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation
More informationARCHITECTURAL DOOR HARDWARE SENSORS CATALOG
ARCHITECTURAL DOOR HARDWARE SENSORS CATALOG January 1, 2017 v3 West Coast Office (800) 544-4422 East Coast Office (800) 225-6737 intldoorclosers.com Index SENSORS X-ZONE T (combined active infrared and
More informationS304 and S305 Dust Emission Monitors. User Manual. Distributor
S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...
More informationMovement-based energy control
04 Movement-based energy control 94 International catalogue 2015 4.1 Microwave-based movement sensors 4.2 PIR-based movement sensors 4.2.1 Ceiling-mount 4.2.2 Wall-mount 4.3 Twilight switches 4.4 LED lights
More information10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable
R Label Detection Sensor E3S-CD68/63 Detect Labels Regardless of Label Color or Luster, Bottle Color or Clarity H High-performance circuitry detects wide variety of labels on clear and colored bottles
More informationANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual
ANALOX 5001 ANALOX 5001 Carbon Dioxide Monitor User Manual Analox Sensor Technology Ltd 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT T: +44 (0)1642 711400 F: +44 (0)1642 713900
More informationTLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.
Installation and Operation Manual RoHS CEDES AG is certified according to ISO 9001: 200808 English Pages 2-12 110 605 130208 V 1.1 Contents 1. About this manual 2 1.1 Measurements 2 1.2 Related documents
More informationMVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions
MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC Operating Instructions We have designed the new MVP-D-TEK vehicle loop detector with the following objectives in mind: 1. Compact package to allow
More informationSELECTION TABLE x 42 x x 48 x x 50 x M12 x 70. Housing material. Typ. operating range/scanning range [mm]
SELECTION TABLE Dimensions in mm (WxHxD) in mm (ØxL) Housing material Typ. operating range/scanning range [mm] 100 500 1000 6000 Series Plastic Metal 420 20 x 42 x 15 10 1000 8 15 x 48 x 38 0 800 We reserve
More informationalarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.
ELECTRONIC ENGINEERING LTD. MRX-300N Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL P/N 7101297 Rev. A Y.S/A.Y 1 The MRX-300N is unique PIR and Microwave
More informationFlostop TS D7E and A8E. Operation Manual
Flostop TS D7E and A8E Operation Manual United Kingdom Spectron Gas Control Systems Ltd, Unit 4, ATU1, University of Warwick science Park, Coventry, +44 (0) 24 7641 6234 sales@spectron-gcs.com Germany
More informationMaxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features
Maxim3 TM Series PROJECT NAME: CATALOG: NOTES: LED Vapor Tight - Waterproof Key Features Up to 146 IP66 87 UL 4, 5 & 8 K & K 110-277V NSF Stainless Steel Clips Operating Temp - o F to 105 o F 7 Year Warranty
More informationGeneral Purpose IO Technical Manual
General Purpose IO Technical Manual Revision 1.06 8 November 2013 Pakton Technologies PAE222 GPIO Manual.docx Page 1 of 21 Revision 1.06 Last updated 8/11/2013 Table of Contents INTRODUCTION...3 Scope
More informationAlarm Panel Operating Instructions
Alarm Panel Operating Instructions 1.0 Introduction The Gascon Systems G8850 alarm panel is designed to be used with gas reticulation systems. It is available in single, twin and triple input channel models.
More informationCeiling PIR HS presence detector. Product Guide. Overview. Features
Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high
More information5.0. Photoelectric Sensors. Technical Reference. Introduction
.0 Technical Reference Photoelectric sensors use light to detect the presence or absence of an object. The main advantages of photoelectric sensors are noncontact sensing of objects and greatly extended
More informationOperation and Maintenance Manual
(FKER Series) Repeater Panel (FKER, FKER, FKER8) Operation and Maintenance Manual Man-9EL Issue June Index Section Page. Introduction.... Safety and mounting.... Technical specification.... Control panel
More informationR-GAGE QT50R-AFS Sensor
Datasheet Radar-Based Sensors for Detection of Moving and Stationary Targets FMCW (true-presence) radar detects moving and stationary objects Higher sensitivity and shorter range Adjustable sensing field
More informationMicrowave Doppler Flow Switch. Installation & Operation Manual
Microwave Doppler Flow Switch Type Microsense DFS Installation & Operation Manual Hycontrol Limited, Larchwood House, Orchard Street,, Redditch, Worcestershire, B98 7DP, England Tel: + 00 44 (0)1527 406800
More informationWater Leak Detector - Four Zone with open/short-circuit detection. Product overview
Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must
More informationIR FLAME DETECTOR RIV-601/F
IR FLAME DETECTOR EN 54-10 class 2 VdS approval G 205044 application manual CONTROL LOGIC rev. 4 DEC07 MAFE DEC07 IR FLAME DETECTORS SUMMARY Page general notions...3 description...4. Electrical and general
More informationSnifter ATEX22 VERSION. User Manual. Distributor
Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5
More informationWIO 200B and WIOI200B Water in oil sensor
WIO 200B and WIOI200B Water in oil sensor User manual Rev. 1.11 111881-944 Rev. 1.11 WIO200B User manual Date: 2017-01-20 03-01-0501-CRJ-04 Side 1 af 61 Table of contents Table of contents... 2 Introduction...
More informationProximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...
Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF... 4 TH Generation TRIPLESHIELD TM Adjustable sensing distance: 2-10 mm Flush or 3- mm Non-flush Protection: short-circuit,
More informationLZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS
LZR -WIDESCAN EN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS User s Guide for product version 0300 and higher See product label for serial number INSTALLATION & MAINTENANCE & TIPS Avoid extreme
More informationENGINEERED PARKING SYSTEMS MODEL 3416D
ENGINEERED PARKING SYSTEMS MODEL 3416D Vehicle Loop Detector Operating Instructions ENGINEERED PARKING SYSTEMS 25010 AVENUE TIBBITTS VALENCIA, CA 91355 (661) 294-0778, (800) 377-4636 www.epsinfo.com We
More information1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses
IXIO-DT INDUSTRIAL Activation & safety sensor for industrial doors (US Version) ENGLISH DESCRIPTION 3 4 5 6 7 8 9 ACCESSORIES. LCD. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain
More informationProximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...
Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF... 4TH Generation TRIPLESHIELD TM Adjustable sensing distance: 2-20 mm flush or 4-30 mm non-flush Protection: short-circuit,
More informationRPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev
RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed
More informationDT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions
DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions QUICK LINKS Mounting Location Guidelines Open the Sensor Mount the Sensor Sensor Components and Settings Wire the Sensor
More informationSIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL
SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL USER MANUAL 1 Table of Contents 1 SAFETY INFORMATION...3 1.1 SAFETY PRECAUTIONS DURING NORMAL OPERATION OF PANEL...3 1.3 BATTERY INFORMATION...3
More informationFlopurge TS. Operation Manual
Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com
More informationRectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English
Rectifier RC-series Manual RC-series English Manual Wall and 19 English Presentation The RC-series is a rectifier for either directly powering the load or for use together with batteries. It is designed
More informationErbium-Doped Fiber Amplifier (EDFA) - MW Series
Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available
More informationINSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #
INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #236477-001 Specifications... 1 Overview Silent Dial Thermostat Art. 236477-001... 1 Mounting Location... 3 DIP Switch Configuration... 3 Calibration... 5 Setting
More information