1 CIMCO, INC. COMMERCIAL-INDUSTRIAL-MECHANICAL-CONTRACTOR WV Contractors License Number WV Billing Address PO Box 480 Culloden, WV Shipping Address 2336 Virginia Ave. Hurricane, WV Phone: Fax: Company Facts Established: April 1996 Corp. Structure: S Corporation Ownership: Mitchell Smith (100%) Type of Work Performed: Bonding Capacity: Bonding Company: Plumbing, HVAC, Piping, and Mechanical Services Up to Approx. $15M per project Travelers Insurance Co Safety EMR: 0.87 Cimco's Philosophy Since the day that we started Cimco, we have targeted larger and more technical projects in the tri-state area. Within 2 months of incorporation, we landed a $1.7M school project and we haven't looked back since. Cimco's financial strength uniquely qualifies us to perform large complex projects, on time and within budget. Cimco has always strived to provide the owner with a quality project at a competitive price, while focusing on the total life cycle cost of the facility. By teaming with the best subcontractors and material suppliers in the market, Cimco has built its reputation on providing facilities that are easy to maintain. We take into consideration maintenance needs, future upgrades, and equipment replacement when installing our mechanical systems. When it is time to turn over the building to the owner, we team with the owner to train their personnel, or Cimco can provide any level of service maintenance through our Building Services Division. Our goal is to help the owner maintain and operate the facility as it was designed.
2 CIMCO, INC. COMMERCIAL-INDUSTRIAL-MECHANICAL-CONTRACTOR WV Contractors License Number WV Safety is paramount at Cimco. Our team is provided with the best tools and training in the industry to ensure we work safely and efficiently. We are committed to our employees and their families that they return home safely at the end of every workday. Cimco has never failed to deliver a project and has never paid liquidated damages on a project. Understanding the project scope and schedule is core to our project management along with our strategy of working with all trades to make the project successful for everyone. Cimco Building Services Division Projects and Expertise Types of projects we perform Institutional (Prisons, Jails, Courthouses) Healthcare (Hospitals, Clinics, MOB's) Education (Higher Ed, Primary Ed, Vocational Schools) Parking Garages Labs Kitchen/ Restaurant Equipment Expertise Preventative Maintenance on all types of HVAC Equipment, Boilers, and Controls Installation and commissioning of HVAC Equipment, Boilers, Backflow Prevention Devices, and Controls Installation, repair, and service on all types of Kitchen and Restaurant Equipment
3 CIMCO, INC. COMMERCIAL - INDUSTRIAL - MECHANICAL -CONTRACTOR WV Contractors License Number WV Team Bios Jeff Gillenwater - Cimco Building Services Division 22 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Commercial Equipment WV Medical Gas KY Journeyman HVAC Mechanic WV Electrician WV Plumbers License Buddy Wingfield - Cimco Building Services Division 18 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Unitary and Commercial Equipment WV Medical Gas KY Apprentice HVAC Mechanic WV Plumbers Journeyman License Roy Bird - Cimco Building Services Division 17 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Commercial Equipment Steam and Hot Water Boiler Specialist Backflow Prevention Assembly Inspector/Tester WV Medical Gas KY Journeyman HVAC Mechanic WV Journeyman Electrician WV Plumbers Journeyman License WV Certified Backflow Prevention Tester
4 CIMCO, INC. COMMERCIAL-INDUSTRIAL-MECHANICAL-CONTRACTOR WV Contractors License Number WV Lee Brown - Cimco Building Services Division 14 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Commercial Equipment 14 Years Experience - Controls Specialist for Tane, Honeywell, and Pneumatic Systems - Specializing in Tane Summit and Honeywell WEBS WV Medical Gas KY Master HVAC Mechanic George Lawson - Cimco Building Services Division 9 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Commercial Equipment - Specializing in Carrier Chillers Backflow Prevention Assembly Inspetor/Tester WV Certitfied Backflow Prevention Tester KY Journeyman HVAC Mechanic WV Journeyman Plumber License Michael Griffith - Cimco Building Services Division 10 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Unitary and Commercial Equipment KY Apprentice HVAC Mechanic David Crowell - Cimco Building Services Division 16 Years Experience - Service and repair of HVAC Systems Boiler and Chiller installation with associated piping WV Master Plumbers License KY Apprentice HVAC Mechanic
5 CIMCO, IN f COMMERCIAL-INDUSTRIAL-MECHANICAL-CONTRACTOR WV Contractors License Number WV Harold Pierson - Cimco Building Services Division 33 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Unitary and Commercial Equipment WV Master Plumber License KY Apprentice HVAC Mechanic Hoshizaki License Trevor James - Cimco Building Services Division 14 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Unitary and Commercial Equipment WV Master Plumbers License KY Apprentice HVAC Mechanic Dennie Craddock- Cimco Building Services Division 16 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Unitary and Commercial Equipment Backflow Presention Assembly Inspector/Tester WV Master Plumbers License KY Journeyman HVAC Mechanic WV Certified Backflow Prevention Tester Wayne Taylor - Cimco Building Services Division 30 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, Restaurant Equipment, and York Unitary and Commercial Equipment WV Journeyman Plumber License WV Medical Gas WV Journeyman Electrician KY Apprentice HVAC Mechanic
6 IMC COMMERCIAL- INDUSTRIAL- MECHANICAL -CONTRACTOR WV Contractors License Number WV Scott Gillenwater- Cimco Building Services Division 14 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Unitary and Commercial Equipment KY Apprentice HVAC Mechanic Virginia Apprentice Pipe Fitter WV Certified Backflow Prevention Tester Mark Fletcher- Cimco Building Services Division 13 Years Experience - Service and repair of HVAC Systems - Carrier, McQuay, Trane, and York Unitary and Commercial Equipment KY Apprentice HVAC Mechanic WV Journeyman Electrician Dustin Bowling - Cimco Building Services Division Apprentice
7 CIMCO, IN COMMERCIAL-INDUSTRIAL-MECHANICAL-CONTRACTOR WV Contractors License Number WV Partial List of Customers Serviced Thomas Memorial Hospital Marshall University Pike County Schools Lincoln County Schools Chili's Bar and Grill Lonestar Steak House Metro 911 Lincoln County 911 First Baptist Church Charleston Civic Center Crossroads Mall Cecil Walker Machinery Hurricane Chevrolet Logan County Commission Paramount Arts Center Trinity Church WV Housing WV State Police Maicom Construction Engineering Excellence Nest International IPT, LLC Kanawha County Public Library Ashley Fruniture
8 CIMCO INC Office: Fax: Billing: PO Box 480, Culloden, WV25510 j Office/Shipping: 2336 Virginia Ave, Hurricane, WV25526 CIMCO Inc. provides a full range of mechanical systems and maintenance to businesses and industries that assures the comfort, conveniences, and productivity of their environment so they receive the maximum benefit from their facilities. Enjoy the luxury of utilizing ONE COMPANY for all of your mechanical needs! CIMCO INC. OFERS THE FOLLOWING SERVICES: BOILER SERVICE Welded Repairs National Board Certified Tube Replacement Tube Repair Refractory Efficency Testing Control Upgrades BUILDING AUTOMATION SERVICE New Construction EMS Installation Retrofit EMS Installations Design Build Systems Installation Existing System Additions & Repairs Pneumatic to DDC Change Outs Pneumatic Controls Repair & Maintenance Preventative Maintenance Contracts CHILLER SERVICE Customized Preventative Maintenance Programs Teardown & Repair Oil Analysis Eddie Current Inspections New Installations Refrigerant Retrofits HVAC SERVICE Installation Repair Parts Preventative Maintenance PIPING SERVICE A.S.M.E. Certified Ammonia Chemical Steam Condensate High & Low Pressure Steam Carbon & Stainless Equipment Installation PLUMBING SERVICE Leak Detection Pipe Location Camera Inspections High Pressure Water Jetting Backflow Prevention Installation & Testing REFRIGERATION SERVICE Walk-in Coolers Walk-In Freezers Display Cases for Food Products Display Cases for Floral Products Merchandise Boxes Low Temperature Chillers Thermal Storage Systems Ice makers Ice Merchandisers Ice Skating Rink PARTS SERVICE Boilers Refrigeration HVAC
9 CIMCO INC. BOILER DIVISION Office: Fax: Cell: Billing: PO Box 480, Culloden, WV Office/Shipping: 2336 Virginia Ave, Hurricane, WV25526 SERVICES INCLUDE: Welded Repairs National Board Certified - R, S, PP Stamp Certified Tube Replacement - Strait, Bent, All Sizes and Thickness Tube Repair - Sectioning, Pad Welding, Rolling, Beading, Seal Welding Refractory - Firebrick, Plastic, Tile, Blanket Insulation, Spray Plating Efficiency Testing - Combustion Analysis with the latest calibrated equipment Control Upgrades - Solid State Processor Controled, Fault Enunciation, and History SPECIALIZING IN: =6 All Manufacturers' Brands Water and Fire Tube Boilers Fron 1 hp to 100,000 Ibs/hr Low and High Pressure Boilers CIMCO INC. Boiler Division is capable of handling all your boiler needs. With over fifty years of combined field experience in this market, we have seen and handled just about every aspect of boiler repair and maintenance. From installation to start-up, annual open and close inspections to emergency repairs, our factor trained technicians provide a fast and efficient response to your boiler needs throughout the Commonwealth of Kentucky and West Virginia. Call Today (304)
10 CIMCO INC. Office: Fax: Billing:PO Box 480, Culloden, WV Office/Shipping: 2336 Virginia Ave, Hurricane, WV25526 CIMCO Inc. offers the following boiler and burner parts: Acutators Air Pressure Switches Amplifiers Backflow Preventer Repair Kits Backflow Preventers Barometric Dampers Blow Down Separators Boiler Feed Pumps Boiler Tubes Boilers, Steel, & Cast Iron Burners Gas, Oil, Waste Gas, & Solid Fuel Chemical Pumps and Feeders Circulator Pumps Condensate Pumps Control Valves Deareators Draft Inducers Expansion Tanks Firebrick Flame Monitor Safety Controls Flame Rods Flue Brushes, Rods, & Scrapers Gas Pressure Regulators Gas Valves Gaskets Gauge Glass Sets, Standard & Heavy Duty Hand Hole Gaskets Hand Hole Assemblies Heat Exchangers, Tube, Plate, & Frame Igniters Ignition Transformers Instantaneous Hot Water Heaters Low Water Controls & Alarms Modulation Controls & Motors Observation Glass Oil Pumps & Nozzles O2 Trim Systems Pipe Insulation Pneumatic Controls & Fittings Pressure Gauges Pressure Controls Programmable Controls & Relays Pump Controls Refractory Materials Relays Relief Valves Safety Valves Solenoid Valves Steam Traps Strainers Temperature Controls Temperature Gauges Thermometers Thermostatic Valves Tabulator
11 CIMCO INC. HVAC DIVISION Office: Fax: Billing: PO Box 480, Culloden, WV Office/Shipping: 2336 Virginia Ave, Hurricane, WV SERVICES INCLUDE: Installation Repair Parts Preventative Maintenance SPECIALIZING IN: Computer Room A/C Units Split Systems Packaged Roof Top Units Air Handler Units Heat Pump Loops Underground systems Thermal Storage Variable and Condensed Air Volume Distribution Systems Makeup Air Units VAV Boxes Ice Machines Indoor Air Quality Air Dryers Cooling Towers Cabinet Coolers Paint Booths CIMCO, Inc. HVAC Division provides you with 24/7 maintenance and repair services. Our experience encompasses large and small projects in a wide range of markets. Throughout West Virginia, we are ready to serve your mechanical system needs. CIMCO, Inc. HVAC Division is capable of handling all of your HVAC needs. With over 100 years of combined field experience in this market, we have seen and handled just about every aspect of HVAC repair and maintenance. From installation and start-up, to emergency repairs, our factory-trained technicians provide a fast and efficient response throughout West Virginia.
12 CIMCO INC. CHILLER DIVISION Office: Fax: Cell: Billing: PO Box 480, Culloden, WV Office/Shipping: 2336 Virginia Ave, Hurricane, WV Air conditioning, Refrigeration Sheet Metal Fabrication Plumbing, Industrial Piping Heating & Ventilating SERVICES INCLUDE: 3=6 All Manufacturers' Brands 3=s Open Drive Centrifugal Liquid *=* Chillers 3=6 Hermetic Centrifugal Chillers Air and Water Cooled Rotary Screw Chillers s=* 1 Ton to 5,000 Tons Low Temperature Chillers to -30 F SPECIALIZING IN: Customized Preventative Maintenance Programs Teardown and Repair oil Analysis Eddie Current Inspections New Installations 3=6 Refrigerant Retrofits CIMCO INC. Chiller Division is capable of handling all of your chiller maintenance needs. With over 80 years of experience in this market, we have seen and handled just about every aspect of chiller maintenance. From start-up to annual inspections to emergy repairs, our factory-trained technicials will provide a fast and efficient response throughout WV and surrounding areas. Contact CIMCO INC. for design, installation, and continued service of your chiller program. Call Today (304)
13 CIMCO INC. REFRIGERATION DIVISION Office: Fax: Cell: Billing: PO Box 480, Culloden, WV j Office/Shipping: 2336 Virginia Ave, Hurricane, WV COMMERCIAL APPLICATIONS Walk-in Coolers 3=6 Walk-in Freezers 3=6 Display Cases for Food Products 3=6 Mechandise Boxes 3=s Low Temperature Chillers 3=6 Thermal Storage Systems 3=6 Ice Makers 3=6 Ice Merchandisers 3=* Ice Skating Rinks INDUSTRIAL APPLICATIONS 3=6 Food Processing Plants 3=s Distilleries s=«poultry Plants 3=«Egg Plants 3««Meat Packing Plants 3= Liquid Chilling Applications 3=6 Process Temperature Control 3=6 Ambient Temperature Control 3=«6 Blast Freezers 3=6 Spiral Freezers s e Cold Storage Warehouses 3=* Freezer Plants Chemical Plants Gas Compression Faclities Refrigerant Manufacturing Plants 3=6 Ice Manufacturing Plants 3=6 Thermal Storage Systems s-=6 Plastics Manufacturing 3=6 Distribution Centers 3=8 Air Inlet Colling for Gas Turbines For the commercial applications, HALOCARBON refrigerants are generally the refrigerant of choice. For industrial applications, AMMONIA is the usual refrigerant selected. AMMONIA is usually selected for industrial applications because of its lower initial cost and its superior operating characteristics in refrigerating capacity and lower energy consumption. In the rare case of a cusomer's choice or regulatory prohibition, HALOCARBONS can also be used in industrial applications.
14 CIMCO INC. Office: Fax: Billing: PO Box 480, Culloden, WV Office/Shipping: 2336 Virginia Ave, Hurricane, WV25526 CIMCO INC OFFERS THE FOLLOWING REFRIGERATION REQUIREMENTS: VALVES Regulator, Solenoid, & Hand: Refrigerating Specialties Vilter Mfg. Corp. Danfoss Henry Valve Co. Hansen Technologies Hubbell Technologies Grasso Relief: Henry Valve Co. Cyrus Shank Refrigeration Specialties Rego Thermo Expansion: Alco Sporlan Specialty: Amot Continental McDonnell & Miller CONTROLS Pressure & Temperature: Penn/Johnson Dwyer/Mercoid United Electric Paragon Liquid Level Refrigerating Specialties Hansen Technologies Magnatrol Phillips VESSELS Frick Jordan Equipment Chil-Con Products E.L. Nickell Co. Vilter Mrg. Corp. Phillips AIR UNITS Frick Frigid Coil IMECO Krack Vilter Mrg. Co. Evapco COMPRESSORS Recip., Screw, Rotary Vane: Frick/Sabroe Vilter Mfg. Corp. F.E.S. Mycom York Fuller Grasso Howe Allis-Chalmers EVAP. CONDENSERS IMECO B.A.C Vilter Evapco REFRIGERATOR OIL Frick York Texaco Mobil PUMPS Cornell Pump Co. Worthington Viking SAFETY EQUIPMENT Pro-Tech MSA Wilson Kappler HALOCARBON EQUIPMENT Frick Kramer Russell Bohn Chandler AC&R Components Vilter Mfg. Corp. Krack Corp. R.S. Flo-Con Hill-Phoenix AMMONIA DETECTORS EDA Controls Vilter Mgs. Corp. Select Technologies Kool Air MISCELLANEOUS Crepaco Wm. W. Nugent Schroeder Dollinger-Technolab X-Pando Cooper Instrument Armstrong International Sullair GAUGES Frick WIKA H.O. Trerice Ashcroft Winter's Ametek ENFM McDaniel Vilter Mfg. Corp. ICE MACHINES North Star Howe Vogt Maintenance SPIRAL FREEZERS Freezing Systems Northfield Bramer PLATE CHILLERS Flat Plate Chester-Jensen Alfa Laval Mueller A.P.V. Turbo CLEAN ROOM & MAKEUP AIR EQUIP Acu-Air Krack Corp Miller-Picking King
15 CIMCO INC. PLUMBING DIVISION Office: Fax: Cell: Billing: PO Box 480, Culloden, WV / Office/Shipping: 2336 Virginia Ave, Hurricane, WV25526 SERVICES INCLUDE: Backflow Prevention and Testing - Your local water supplier may now require annual testing and certified installation. 24 Hour Service. Drain piping replacement and repairs of all sizes and types. 3=6 Pump replacement and repairs all types and brands. CIMCO INC. Plumbing Division is capable of handling all your boiler needs. With over fifty years of combined field experience in this market, we have seen and handled just about every aspect of plumbing repair and maintenance. Our factor trained technicians provide a fast and efficient response to your boiler needs throughout the Commonwealth of Kentucky and West Virginia. Call Today (304)
16 CIMCO INC. PIPING DIVISION Office: Fax: Cell: Billing: PO Box 480, Culloden, WV / Office/Shipping: 2336 Virginia Ave, Hurricane, WV SERVICES INCLUDE: A.S.M.E. Certified Ammonia Steam Condensate High & Low Pressure Steam Equipment Installation SPECIALIZING IN: i e 3=6 3=6 3=6 i 5 Industrial Piping Stainless Steel Carbon Steel PVC & CPVC HDPE&HDPP Copper Galvanized Threaded, Grooved, & Welded Jacketed Piping Control Trace Installation Polyethylene Pipe CIMCO INC. Piping Division will provide you with 24 hours / 7 days a week repair & maintenance services. Throughout the Commonwealth of Kentucky and West Virginia, we are ready to serve your mechanical system needs. CIMCO INC. Piping Division is capable of handling all of your Piping needs. With over 100 years combined field experience in this market, we have seen and handled just about every aspect of piping repair and maintenance. Call Today (304)
C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.
SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers
More informationPITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS
PITTSBURG STATE UNIVERSITY HVAC and BUILDING AUTOMATION SYSTEM STANDARDS CHILLERS In new construction, liquid-cooled models are preferred for systems larger than 100 ton. o Trane, York and McQuay brands
More informationA. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.
15684 ROTARY SCREW WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236423 An optional
More informationSECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower
SECTION 15682 CENTRIFUGAL WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC) 3. 15711 - Induced Draft Cooling Tower B. Removal
More informationSECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower
SECTION 15684 ROTARY SCREW WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC) 3. 15711 - Induced Draft Cooling Tower B.
More information"This is only the scope of work for the project. For more information, interested parties should contact Procurement at
"This is only the scope of work for the project. For more information, interested parties should contact Procurement at purchasing@stpgov.org to ensure receipt of a full bid package, to be listed as a
More informationPackaged Semi-Instantaneous Steam Fired Water Heater
MODEL STX Packaged Semi-Instantaneous Steam Fired Water Heater Shell and Tube Style Heater Features Reliable Only high grade materials used in construction to ensure long operating life Heat exchange pressure
More informationPackaged Steam Fired Water Heater
MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction
More informationSECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller:
SECTION 15684 ROTARY SCREW WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC). 3. 15711 - Induced Draft Cooling Tower. B.
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. Design and specify refrigeration systems and equipment in accordance with "Energy Conservation Standards" stipulated in Section 15010, Basic
More informationCook - Wissahickon Elementary School
Cook - Wissahickon Elementary School 201 E. Salaignac St., Philadelphia, PA 19128 HVAC Replacement Project Scope Determination Report May 10, 2018 Prepared by: G.P. Lamina, Jr., P.E., MBA School District
More informationSECTION AIR COOLED WATER CHILLERS
PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2
More informationSECTION ROTARY-SCREW WATER CHILLERS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.
More informationBryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired
Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20
More informationA. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.
15682 CENTRIFUGAL WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236416 An optional
More informationSECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.
SECTION 15650 REFRIGERATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. 4. Air
More informationPART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. To obtain maintenance and repair standards for boiler burners (Section 15555A) and boiler tubes (Section 15555B), contact the DPS Project
More informationAIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University
AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort
More informationMAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.
Temperature Control Units Water & Oil 30-500 F Portable Chillers Air & Water-Cooled 20-70 F Central Chillers Air & Water-Cooled Packages & Modules 20-70 F Pump Tank Stations Chilled or Tower Water 200-3600
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationNEW CHILLER SCHEDULE
TITLE: REPLACE CHILLER MACC MAXIMO # 4542690 PROJECT # 14M108CN MACC # 14-0459 ATTACHMENTS: 1. MAXIMO Equipment update form SCOPE OF WORK: The contractor shall provide all material, labor, equipment, and
More informationRSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016
This Table of Contents lists the complete contents of the RSES s (SAM) issued to date. Section 1 Refrigeration 620-05 Principles of Refrigeration Part 1 620-06 Principles of Refrigeration Part 2 620-67
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationHigh Capacity Instantaneous Steam Fired Water Heater
MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and
More informationCONTENTS. B. System Design and Performance Requirements
15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More information"This is only the scope of work for the project. For more information, interested parties should contact Procurement at
"This is only the scope of work for the project. For more information, interested parties should contact Procurement at purchasing@stpgov.org to ensure receipt of a full bid package, to be listed as a
More informationBurner Comparisons. Typical Competitor s Burner
Burner Comparisons INOV8 s Typical Competitor s Burner Automatic nozzle cleanout Yes No Available BTUs rated as input 100,000 to 1,000,000 76,500 to 500,000 Burner Motor - hp 1/5 1/7 Combustion safety
More informationSemi-Instantaneous Indirect Fired Water Heater
MODEL BWX Semi-Instantaneous Indirect Fired Water Heater Use Boiler Water Or HTHW To Heat Domestic Water Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone
More informationSECTION HEATING BOILERS
SECTION 23 52 00 HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes boilers, controls and boiler trim, steam and condensate connections, hot water connections, fuel burning system and connections,
More informationInstant hot water Feed-Forward system unlimited supply accurate to +/- 4 F
Count on Graham for proven reliability. Graham is one of the world s foremost designers and manufacturers of vacuum and heat transfer equipment with over a half-century of proven experience. Our in-house
More informationAUXILIARY EQUIPMENT FOR ALL YOUR NEEDS
AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS TEMPERATURE CONTROLLERS - WATER UNITS VT Series temperature controllers are used for process temperature control to 250 F. These units use an incoloy heater and centrifugal
More informationINTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:
At Bradford White, we believe in giving you a feature-packed, premium product at the best possible price. We proudly build quality and value into each and every product we manufacture. We believe when
More informationSECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.
SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400
More informationCASE STUDY AIR-CONDITIONERS
CASE STUDY AIR-CONDITIONERS An Investment in Longer Lasting Quality ABOUT US BT Commercial Ltd. is a dynamic and diversified company, which has been in operation since 1992. Our company, which is growing
More information21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device
DIVISION 23800 APPENDIX A ASHTABULA CAMPUS: 1. Air Handling Equipment And Appurtenances 2. Exhaust Fans 3. Fume Hood Exhaust Fans 4. Fume Hood monitoring devices and annual certification of face velocity
More informationASME Packaged Indirect Fired Water Heater
Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining provides superior protection and tank longevity Heavy duty construction withstands
More informationSECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS
SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the
More informationSECTION DOMESTIC WATER HEATERS
SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationHVAC Service Technicians Training Center
HVAC Service Technicians Training Center 48-03 32 nd Place, Long Island City, NY 11101 Tel: (718) 472-0404 (718) 472-0414 Fax: (718) 433-0676 Introduction to the Refrigeration Cycle: Part 1 (AC/R-1) This
More informationCertification Programs, Standards,
Certification Programs, Standards, and Guidelines Visit the AHRI Directory www.ahridirectory.org View and download AHRI Standards and Guidelines www.ahrinet.org Certification Programs, Standards, and
More informationDOCUMENT TABLE OF CONTENTS
DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026
More informationSECTION SPLIT-SYSTEM AIR-CONDITIONERS
SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationSAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER
SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section
More informationConversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler
Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW
More informationA-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents
Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA
More informationSECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...
SECTION 230001 TABLE OF CONTENTS SECTION 230001 PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS... 1 1.00 FILED SUB BID... 1 1.01 PROJECT OVERVIEW... 2 1.02 DESIGN CRITERIA... 4 1.03 CODE ISSUES...
More informationAHRI Certification Program Scopes - COOLING
Air-to-Air Energy Recovery Ventilators (AHRI Std. 1060) Automatic Commercial Ice-Cube Machines and Ice Storage Bins (AHRI Stds. 810 & 820) Central Station Air-Handling Units (AHRI Std. 430) Commercial
More informationBryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity
Form No. 2300-7 (Rev. 2/99) Gas, il or Dual Fuel Fired Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity Originators of the Flexible Water Tube
More informationDIVISION 15 MECHANICAL
DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with
More informationSeries. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost
LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More informationDESIGN STANDARDS SECTION 15600
PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating
More informationINFRARED HVAC APPLICATION HVAC 101
INFRARED HVAC APPLICATION HVAC 101 John Cannamela Owner ISC Building Diagnostics HVAC Journeyman since 1989 Start up test and Balance since 1992 Level II Thermographer Level II Vibration Level I Eddy current
More informationSECTION HYDRONIC PIPING AND SPECIALTIES
SECTION 15511 HYDRONIC PIPING AND SPECIALTIES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Pipe Materials. 2. Fittings. 3. Specialty Items. 4. Glycol Antifreeze Protection. 5. Process Cooling B.
More informationSafario Cooling Factory LLC
Safario Cooling Factory LLC Since 1999, Safario Cooling Factory LLC has been maintaining as a leading manufacturer of Commercial and Industrial HVAC coils, chilled water coils, chiller coils, steam coils,
More informationSTEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.
1 1 1 1 1 1 1 1 0 1 0 1 SECTION 1 PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES A. Chiller package. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled
More informationSECTION SPLIT-SYSTEM AIR-CONDITIONERS
SECTION 23 81 26 SPLIT-SYSTEM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.
More informationHORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).
SECTION 15555 HORIZONTAL FIRE TUBE BOILERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15510 - Piping (HVAC). 2. 15540 - Pumping Equipment (HVAC). 1.02 SUBMITTALS A. Submit properly identified
More informationHVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS
230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled
More informationSECTION FUEL-FIRED, DOMESTIC WATER HEATERS
SECTION 22 34 00 FUEL-FIRED, DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationUniversity of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL
SECTION 22 14 00 DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 00 10,
More informationAFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh
WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION
More informationConstruction Standards Page
Construction Standards Page 236313-1 SECTION 236313 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationEnergy-Efficiency Measures List
Guidelines for Public Agencies Energy-Efficiency Measures List 1.0 Envelope 1.1 Reduce Heat Losses-Ceiling/roof 1.11 Additional Ceiling/Roof Insulation 1.12 Exhaust Attics 1.13 Use Light-Colored Roof Surfaces
More information1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.
Page 238239-1 SECTION 238239 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationAppendix 13. Categories of Cooling and Heating systems
EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01
More informationRefrigeration and. Modern. Air Conditioning. Bracciano, BS, M.Ed., Ed. Sp. Alfred F. Andrew D. Althouse, BS, (ME), MA. Carl H. Tumquist, BS, (ME), MA
Modern Refrigeration and Air Conditioning by Andrew D. Althouse, BS, (ME), MA Technical-Vocational Education Consultant Life Member, American Society of Heating, Refrigeration, and Air-Conditioning Engineers
More informationDESIGN GUIDELINES SECTION HVAC
3/15/17 Cooling Methodology Chiller Plants Configurations monitoring Preferred DESIGN GUIDELINES SECTION 15700 HVAC Air-cooled chillers < or = 300 tons; water-cooled chillers > 300 tons Variable volume
More informationFigure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)
Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems) Figure 17-2 Commercial refrigeration Unit Figure 17-3 Industrial process chiller Figure 17-4 Basic refrigeration
More informationSECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS
SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from
More informationRefrigeration Plant Information. We Speak Hockey 365
Refrigeration Plant Information We Speak Hockey 365 Introduction For 100 years, it s been accepted that ice rinks come with a multitude of expensive and reoccurring problems; not to mention astoundingly
More informationSECTION (15530) - REFRIGERANT PIPING
SECTION 23 23 00 (15530) - REFRIGERANT PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. 3. Joining Materials. 4. Specialties. B. Related Sections: 1. Section 07 92 00 (07920)
More informationTECHNICAL. Series 18. Pump Packages
TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump
More informationTemptek Auxiliary Equipment
Temptek Auxiliary Equipment Mold Temperature Controllers - Water Units VT-275-LX VT Series Mold Temperature Controllers are used to process temperature control to 250 F. These units use an incoloy heater
More informationCLASSIFIED PERSONNEL POSITION AVAILABLE POSTED: NOVEMBER 28, 2017 OPEN: UNTIL FILLED HVAC TECHNICIAN
Hickman Mills C-1 School District 9000 Old Santa Fe Rd. Kansas City MO 64138 816-316-7217 CLASSIFIED PERSONNEL POSITION AVAILABLE POSTED: NOVEMBER 28, 2017 OPEN: UNTIL FILLED HVAC TECHNICIAN SALARY RANGE:
More informationSECTION WATER-TUBE BOILERS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationState College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT
State College Area School District High School South Building Prepared by CenterPoint Engineering 08 February 2013 FACILITY ASSESSMENT SUMMARY PHYSICAL PLANT General HVAC This report is a snapshot of the
More informationSCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE
SCHEDULE OF S Penalty Fees. The fee for construction work performed before securing permit(s), where required, may be charged a fee of TWO TIMES THE COST OF THE PERMIT (S). Building Fee Schedule Residential
More informationBuildingName The Description of the Project P DOCUMENTS
ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION
More informationSECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof
More informationAPPA Institute for Facilities Management. Energy & Utilities Cooling Production (316) Purpose of Today s Presentation. Agenda
APPA Institute for Facilities Management Energy & Utilities Cooling Production (316) Mark St. Onge, EFP 1 Purpose of Today s Presentation To provide a broad understanding of central cooling production
More informationATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL
LINE ITEM # ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL LINE ITEM DETAIL Labor Material FURNACE COMPONENTS 1 Furnish & Install Sight-Impaired Thermostat For Heating and Cooling
More informationDIVISION FINNED WATER-TUBE WATER HEATERS
DELTA LIMITED, TYPE WH - MODELS 399B-899B SUGGESTED SPECIFICATIONS Catalog No.: 3500.97B Effective: 04-01-17 Replaces: 11-15-08 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY
More informationMulti-Institutional Academic Health Science & Research Center Evansville, IN
SECTION 236426.11 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationProduct Lines
2017-2018 Product Lines Refrigeration Equipment & System Components Controls, Motors, & Electrical Components HVAC & Hydronic Equipment HVAC & Hydronic System Components Food Service Equipment Instruments
More information1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.
SECTION 15855 GAS FURNACE/DX COOLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of contract including General and Supplementary Conditions of Division 1 of Specification
More informationFlorida Department of Education Curriculum Framework
Florida Department of Education Curriculum Framework 2013 2014 Program Title: Air-Conditioning, Refrigeration and Heating Technology 2 Program Type: Career Preparatory Career Cluster: Architecture and
More informationExclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA
Page 236423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical Plant
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS
PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate
More information1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT
Taylor Engineering 1080 Marina Village Parkway, Suite 501 Alameda, CA 94501-1142 (510) 749-9135 Fax (510) 749-9136 LLC HVAC DESIGN INTENT PART 1 - GENERAL 1.1 Overview A. The project consists of a 3-story
More informationEnergy Management and Controls
As with the Chapter Review Tests and the Final Exam, the tests your understanding of the materials underlying the learning objectives. After you ve reviewed your answers to the Chapter Review Tests, try
More informationCOMcheck Software Version Review Mechanical Compliance Certificate
COMcheck Software Version 4.0.7.2 Review Mechanical Compliance Certificate Section 1: Project Information Energy Code: 2014 Oregon Energy Efficiency Specialty Code Project Title: Benton County Health Project
More informationDIVISION FINNED WATER-TUBE WATER HEATERS
HI DELTA, TYPE WH - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 3500.932A Effective: 04-01-17 Replaces: 10-31-16 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY A.
More informationBETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.
BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS. Value & Premier Oil Heating System Service Plans Choose the plan that s best for you and your home. WE PROMISE SERVICE PLANS THAT
More information150 BHP, 3 Pass High-Pressure Fire Tube Boiler mounted in a 53 Trailer
March 1, 2017 150 BHP, 3 Pass High-Pressure Fire Tube Boiler mounted in a 53 Trailer Customer Carey Boiler Works March 1, 2017 Page 2 of 5 Section 10 Boiler... 2 10.1... 2 10.2 Design... 2 10.3 Technical
More informationCopyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services
Page 238216-1 Copyright 2003 and 2005 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical
More informationImproving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions.
Improving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions www.danfoss.com Agenda Brief on Danfoss Danfoss Business Divisions / Areas Danfoss Drive Solutions for Energy Efficiency in
More informationDIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS
XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY
More information