NGO Ventless Submittal Information

Size: px
Start display at page:

Download "NGO Ventless Submittal Information"

Transcription

1 TurboChef Technologies Inc. NGO Ventless Submittal Information Spec Sheet 1.1 TurboChef Model/Part Number Guide 2.1 UL Ventless Label 3.1 Notice of Authorization to Apply to UL Mark 4.1 UL Listing 5.1 UL KNLZ Explained 6.1 KNLZ Letter 7.1 Emissions Test Results 8.1 Emissions by Product 9.1 Fire and Smoke Statement 10.1 Energy Usage Estimate 11.1 Surface Temperatures 12.1 LA City RR Certification Approval TurboChef Technologies, Inc. DOC-1217 / Rev E / Mar 2010

2 Page 1.1 THE NGO TM PERFORMANCE Utilizing TurboChef s patented technology to rapidly cook food without compromising quality, the NGO provides superior cooking performance while requiring less space and consuming less energy. VENTILATION UL 710B (KNLZ) listed for ventless operation. EPA 202 test (8 hr): - Product: Pepperoni Pizzas - Results: 0.64 mg/m 3 - Ventless Requirement: <5.00 mg/m 3 Internal catalytic filtration to limit smoke, grease, and odor emissions. SPECIFICATION SHEET EXTERIOR CONSTRUCTION Powder coated, corrosion-resistant steel outer wrap and door Die-cast aluminum front panels with matte-nickel accents Cool-to-touch exterior; all surfaces below 50 C Ergonomic matte-nickel door handle 4-inch nickel-plated legs INTERIOR CONSTRUCTION 201/304 stainless steel Fully welded and insulated cook chamber Removable rack and lower jetplate STANDARD FEATURES Independently-controlled dual motors for vertically-recirculated air impingement Top-launched microwave system Stirrer to help ensure even distribution of air and microwave Integral recirculating catalytic converter for UL 710B (KNLZ) listed ventless operation External air filtration Vent catalyst to further limit emissions and odors Smart menu system capable of storing up to 1,024 recipes Flash firmware updates via smart card Single or multiple-temperature interface Built-in self-diagnostics for monitoring oven components and performance Compatible with Oven Connect TM and ChefComm Pro Smart Voltage Sensor Technology* (U.S. only) Stackable (requires stacking stand) Warranty 1 year parts and labor CAT 5 Connection COMES WITH STANDARD ACCESSORIES 1 Bottle Oven Cleaner (103180) 1 Trigger Sprayer (103182) 1 Hard Anodized Cooking Tray (i1-9496) NGO TM FOR STARBUCKS COFFEE COMPANY This product conforms to the ventilation recommendations set forth by NFPA96 using EPA202 test method. * Smart Voltage Sensor Technology does not compensate for lack of or over voltage situations. It is the responsibility of the owner to supply voltage to the unit according to the specifi cations on the back of this sheet. 1. Blower Motors 2. Microwave System 3. Stirred Impinged Air (Top) and Microwave 4. Impinged Air (Bottom) 5. Catalytic Converter 6. Impingement Heater 7. Vent Tube Catalyst 8. Air Filter 9. Inlet Air for Cooling Electronic Components Ventless certifi cation is for all food items except for foods classifi ed as fatty raw proteins. Such foods include bone-in, skin-on chicken, raw hamburger meat, raw bacon, raw sausage, steaks, etc. If cooking these types of foods, consult local HVAC codes and authorities to ensure compliance with ventilation requirements. Ultimate ventless allowance is dependent upon AHJ approval, as some jurisdictions may not recognize UL certification or application. If you have questions regarding ventless certifications or local codes please ventless.help@turbochef.com TurboChef reserves the right to make substitutions of components or change specifi cations without prior notice. DOC-1143/Revision F/ December 2009

3 Page 1.2 NGO TM FOR STARBUCKS COFFEE COMPANY 25.0 (635 mm) 16.0 (406 mm) 11.8 (299.7 mm) 27.3 (693 mm) 21.0 (533 mm) 4.0 (102 mm) 2.5 (64 mm) 10.7 (272 mm) 25.9 (658 mm) 39.1 (993 mm) 2.5 (64 mm) US, CAN, LA (2L + G) UK, BK, JK (L + N + G) ED, BD, JD, SD (3L + G) EW, KW (3L + N + G) 18.5 (470 mm) 4.2 (107 mm) SINGLE UNIT DIMENSIONS Height mm Width mm Depth mm Weight 170 lb kg COOK CHAMBER Height mm Width mm Depth mm Volume 0.54 cu.ft liters WALL CLEARANCE (Oven not intended for built-in installation) Top mm Sides* 2 51 mm SHIPPING INFORMATION U.S.: All ovens shipped within the U.S. are packaged in a double-wall corrugated box banded to a wooden skid. International: All International ovens shipped via Air or Less than Container Loads are packaged in wooden crates. Box size: 38 x 26 x 37 (965 mm x 660 mm x 940 mm) Crate size: 38 x 26 x 39 (965 mm x 660 mm x 991 mm) Item class: 85 NMFC #26770 HS code Approximate crated weight: 290 lb. (131.5 kg) Minimum entry clearance required for box: 38.5 (978 mm) Minimum entry clearance required for crate: 39.5 (1,003 mm) * Side clearance required for electrical component ventilation. ELECTRICAL SPECIFICATIONS SINGLE PHASE US/Canada SKU: / i /240 VAC, 60 Hz, 30 amps, 6.2 kw International SKU: / i uk 230 VAC, 50 Hz, 27 amps, 6.2 kw International SKU: / i bk 220 VAC, 60 Hz, 28 amps, 6.2 kw International SKU: / i la 220 VAC, 60 Hz, 28 amps, 6.2 kw International SKU: / i jk 200 VAC, 50 Hz, 30 amps, 6.2 kw International SKU: / i jk 200 VAC, 60 Hz, 30 amps, 6.2 kw MULTIPHASE International SKU: / i ed 230 VAC, 50 Hz, 20 amps, 6.2 kw International SKU: / i ew 400 VAC, 50 Hz, 16 amps, 6.2 kw International SKU: / i jd 200 VAC, 50 Hz, 20 amps, 6.2 kw International SKU: / i jd 200 VAC, 60 Hz, 20 amps, 6.2 kw International SKU: / i kw 400 VAC, 60 Hz, 16 amps, 6.2 kw International SKU: / i sd 230 VAC, 60 Hz, 20 amps, 6.2 kw TurboChef requires installing a type D circuit breaker for all installations. TurboChef Global Operations 4240 International Pkwy, Suite 105 Carrollton, Texas USA US: TURBO ( ) International: Fax: TurboChef Technologies, Inc.

4 Page 2.1 October 14, 2009 Authority Having Jurisdiction Re: TurboChef Model number/part Number Scheme To Whom It May Concern: The TurboChef warming oven for Starbucks Coffee Company is a designated as the TurboChef Model: NGO The Part Number Designation for the base oven is: NGO-9501-XX-YY Where XX can be any unique combination of numbers (0-99), and where YY can be any combination of 2 letters, or omitted depending on the oven s electrical configuration. The XX parameter changes per the customers specification: however, the specification does not affect the oven s base configuration or any of its Safety, Ventilation, or Sanitation Certifications. Respectfully submitted, James K. Pool III Senior Vice President Engineering Procurement TurboChef Technologies Inc o c

5 Page 3.1

6 Page 4.1 NOTICE OF AUTHORIZATION TO APPLY THE UL MARK Turbochef Technologies Inc Mr. David Castillo Suite International Pky Carrollton Tx 75007, Us 10/12/2009 Our Reference: File E151487, Vol. TO BE DETERMINED Your Reference: David Castillo 8/8/09 Project Scope: Dear Mr. David Castillo: Project Number 09NK11970 UL/cUL KNLZ Complementary Listing Investigation for New Model NGO Oven in File E Vol.1 Sec.10 UL's investigation of your product(s) has been completed under the above Reference Number and the product was determined to comply with the applicable requirements. This letter temporarily supplements the UL Follow-Up Services Procedure and serves as authorization to apply the UL Mark only at authorized factories under UL's Follow-Up Service Program. To provide the manufacturer with the intended authorization to use the UL Mark, the addressee must send a copy of this notice to each manufacturing location currently authorized in File E151487, Vol. TO BE DETERMINED. This authorization is effective from the date of this Notice and only for products at the indicated manufacturing locations. Records in the Follow-Up Services Procedure covering the product are now being prepared and will be sent in the near future. This letter authorizes application of the UL Mark for 90 days from the date of this letter. Products that bear the UL Mark shall be identical to those that were evaluated by UL and found to comply with UL s requirements. If changes in construction are discovered, appropriate action will be taken for products not in conformance with UL s requirements and continued use of the UL Mark may be withdrawn. UL may elect to withdraw use of the UL Mark if the Applicant or Manufacturer fails to comply with UL s requirements including ongoing compliance of the product, under UL s Follow-Up Service. This is an electronically generated letter. Signatures are not required for this document to be valid. Page 1 of 2

7 Page 4.2 Notice of Authorization - 09NK11970 Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. The contents of this Letter are intended solely for the use of UL and the Applicant. The opinions and findings of UL represent its judgment given with due consideration to the necessary limitations of practical operation in accordance with UL s objectives and purposes. UL shall not otherwise be responsible for the use of or reliance upon the contents of this letter by anyone. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental, consequential or punitive damages, arising out of or in connection with the use or reliance upon the contents of this letter to anyone other than the Applicant as provided in the agreement between UL and Applicant. Any use or reference to UL s name or certification mark(s) by anyone other than the Applicant in accordance with the agreement is prohibited without the express written approval of UL. Very truly yours, William Morler Project Engineer William.Morler@us.ul.com Reviewed by: Fred Zaplatosch Staff Engineer Fred.Zaplatosch@us.ul.com NBKD5F8-399CA5 This is an electronically generated letter. Signatures are not required for this document to be valid. Page 2 of 2

8 1 of 1 5/27/2009 9:08 AM KNLZ.E Commercial Cooking Appliances with Integral Systems... Page 5.1 KNLZ.E Commercial Cooking Appliances with Integral Systems for Limiting the Emission of Grease-laden Air Page Bottom Commercial Cooking Appliances with Integral Systems for Limiting the Emission of Grease-laden Air See General Information for Commercial Cooking Appliances with Integral Systems for Limiting the Emission of Grease-laden Air TURBOCHEF TECHNOLOGIES INC SUITE INTERNATIONAL PKY CARROLLTON, TX USA E Commercial microwave/convection ovens, Models C3/C, HHB, NGC, i3, i5, NGO. Last Updated on Questions? Notice of Disclaimer Page Top Copyright 2009 Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2009 Underwriters Laboratories Inc. "

9 8/28/2008 KNLZ.GuideInfo - Commercial Cooking Appliances with Integral Systems for Limiting the Emission of... Page 6.1 KNLZ.GuideInfo Commercial Cooking Appliances with Integral Systems for Limiting the Emission of Grease-laden Air View Listings Page Bottom [Heaters and Heating Equipment] (Heaters, Cooking Appliances) Commercial Cooking Appliances with Integral Systems for Limiting the Emission of Grease-laden Air See General Information for Heaters, Cooking Appliances This category covers cooking equipment intended for commercial use, such as pressurized deep fat fryers and other appliances for use in commercial kitchens, restaurants or other business establishments where food is prepared. Each appliance covered in this category is manufactured with an integral system feature to limit the emission of grease-laden air from the cooking process to the room ambient. These appliances have been evaluated for the limit of 5 mg/m 3 for the emission of grease-laden air to the room ambient in accordance with the recommendations of the National Fire Protection Association Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96, using the EPA-202 test method prescribed for cooking appliances provided with integral recirculating air systems. These products are not intended for connection to a ducted exhaust system. Appliances in this category are not provided with an integral fire extinguishing system. Authorities having jurisdiction should be consulted as to the requirements for this equipment with respect to fire extinguishing systems, such as the need for field installed systems in accordance with NFPA 96. For products with integral recirculating systems including fire extinguishing systems, refer to Commercial, with Integral Recirculating Systems (KNKG). In cases where the nature or construction of equipment is such that special precautions beyond the requirements of the National Electrical Code must be observed in installations or use, suitable warning or special instructions are marked on the equipment. Appliances Listed in this category are suitable for wiring with either copper or aluminum power supply conductors unless marked "Use Copper Wire Only For Power Supply Connections". Commercial cooking appliances of certain types are designed for permanent connections to water supply and sewer lines at the point of installation. Authorities having jurisdiction should be consulted as to the requirements for this equipment with respect to sanitation and connection to water supply and waste disposal lines. Neither the toxicity of coatings nor the physiological effects on persons consuming food products prepared by use of these appliances has been investigated. For cooking oil filters that are not an integral part of another appliance, see Commercial Filters for Cooking Oil (KNRF). For additional information, see Electrical Equipment for Use in Ordinary Locations (AALZ) and Heating, Cooling, Ventilating and Cooking Equipment (AAHC). The basic standard used to investigate products in this category is ANSI/UL 197, "Commercial Electric Cooking Appliances". Appliances Listed in this category with an integral cooking oil filter have been additionally investigated to the requirements in the standard "Commercial Filters for Cooking Oil", ANSI/UL The Listing Mark of Underwriters Laboratories Inc. on the product is the only method provided by UL to identify products manufactured under its Listing and Follow-Up Service. The Listing Mark for these products includes the name and/or symbol of Underwriters Laboratories Inc. (as illustrated in the Introduction of this Directory) together with the word "LISTED," a control number and one of the following product names as appropriate: "Commercial Cooking Appliance," "Cooking Appliance," or other appropriate product identity specified in the individual Listing, along with the words "with integral system for limiting the emission of grease-laden air. "

10 8/28/2008 KNLZ.GuideInfo - Commercial Cooking Appliances with Integral Systems for Limiting the Emission of... Page 6.2 Last Updated on Questions? Notice of Disclaimer Page Top Copyright 2008 Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2008 Underwriters Laboratories Inc. "

11 Page 7.1 April 10, 2007 Mr. James Pool Turbochef Technologies Inc Suite International Pky Carrollton, TX United States Our Reference: File E Subject: INTEGRAL RECIRCIRCULATING SYSTEM Dear Mr. Pool: In reply to your message received today, I offer the following. Products in the KNLZ category (as well as KNKG) are evaluated to UL710B. It used to be that UL197 and supplement SB in UL197 was the standard that they were evaluated to. Basically, UL197 and Supplement SB became UL710B. There is no more Supplement SB in UL197 (9th Ed.). Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. Very truly yours, Fred Zaplatosch Staff Engineer 3015CNBK Tel: Fax: fred.zaplatosch@us.ul.com

12 Page 8.1 File: E Project: 09NK11970 Date: 9/23/2009 Client: TurboChef Technologies Model: Product Tested NGO 9 in. Pepperoni Pizza

13 Project No. 09NK11970 File: E Page 8.2 TurboChef Technologies Model: NGO Calculations needed for Nozzle Size = % Oxygen = %O 2 % Carbon = 0.01 %CO2 Stack Temperature = 28.6 C Barametric Pressure = 744 mmhg Stack Static Pressure = mm H2O Average Square root P = P mm H2O # Travers Points This number is calculated when device is calibrated Oxygen inside stack during operation Carbon Dioxide inside stack during operation Temperature inside stack during operation Barametric pressure at location of meter Static Pressure inside of duct Enter pressure differential at each transvers point in mm H2O, the take square root of P. Pressure CFM Pressure CFM Average Meter Temperature = 22 C Pitot Tube Coefficient = 0.84 % Moisture = 49.7 Sample Rate = Lpm Ideal Nozzle Size mm When numbers are entered into calculator, ideal nozzle size will be displayed. Enter number here in Actual Nozzle Size Used 1/2 in If ideal nozzle size is not available, locate nearest number. Enter what nozzle size was used for testing

14 Project No. 09NK11970 File: E Page 8.3 Start Time: 9:15 TurboChef Technologies Model: NGO Product Tested: 9 in. Pepperoni Pizza Cook Time: 100sec End Time: 5:30 Barometric Pressure: 744 mmhg Test Date: 09/23/09 Recovery Time: 0sec Room Ambient: 23C Filter Paper Start of Test: Filter Paper End of Test: g Frit g IMPINGER WEIGHT Impinger 1 (ml) 2 (ml) 3 (ml) 4 (g) Start Volume/Weight Start Weight (lbs) End Volume/Weight / / / Timed Meter Readings End Weight (lbs) Traverse Point Number Sampling Time Hr/Sec Gas Meter Reading (m 3 ) Orafice Pressure Differential H Velocity Head P Pump Vaccum In.hg Stack Temp C Probe Temp C Box Temp C Impinger Temp C Gas Meter Outlet C Initial : : : : : hr : : : : : hr

15 Traverse Point Number Sampling Time Hr/Sec Gas Meter Reading (m 3 ) Orafice Pressure Differential H Velocity Head P Pump Vaccum In.hg Stack Temp C Probe Temp C Box Temp C Impinger Temp C Gas Meter Outlet C 3 : : : : : hr : : : : : hr : : : : : hr : : : : : hr : : : : : hr : : : : : hr Page 8.4 Average Gas Meter Outlet Temperature: Average Gas Meter Outlet Temperature: C F H = mm H2O Tm = R H = in H2O

16 Project No. 09NK11970 File: E Page 8.5 TurboChef Technologies Model: NGO Start Time: 9:15 End Time: 5:30 Test Date: 09/23/09 Cook Time: 100sec Product Tested: 9 in. Pepperoni Pizza Recovery Time: 0sec Barometric Pressure: 744 Post-Test Data Gas Meter Reading initial m 3 Gas Meter Reading End m 3 Vm m ft 3 Y- Constant Tstd constant R This data is obtained during device calibration. Verify number with most recent calibration certification on LEM Tm Barometric Pressure Pstd H Vmstd Filter paper Filter AR delta H R 744 mmhg inhg inhg in H2O ft m mg mg 0.60 mg Number obtained from Datasheet Barometric Pressure on day of Test Post-Filter Data Weight at End of Test Weight at Begining of Test Change of Weight at End of Test Post-Acid Used Acetone Wash 3.1 mg Bottle 2 Mc 5.1 mg Acetone Blank 0 mg Bottle 3 Impinger Contents 0.5 mg Bottle 4 Mn 5.7 mg MeCl Wash 1.6 mg Bottle 5 MeCl Blank 0 mg Bottle 6 Water Blank 0.1 mg Bottle 7 Total Grease Emisions Cs=Mn/Vmstd 0.64 mg/m3

17 Page 9.1 UL 710B (KNLZ) Emissions by Product Pizza's Cooked Emissions Product Cooked per 8 hour period PM Emissions [ppm] C3/C HHB i5 i3 NGC TurboChef Model NGO 0

18 Page 10.1 October 18, 2004 Mr. Mike Denny Building Services, 224 West Knight St. City of Sioux Falls, South Dakota, Ph: Re: Fire and smoke containment Dear Mr. Denny: The TurboChef ovens have been extensively tested and conform to UL 923 and UL KNLZ standards. The UL 923 standard is the electrical/product safety standard and the KNLZ is the low particulate matter emissions standard to which we conform. While both standards address difference aspects of the oven, they both have inherent overlap as it relates to grease/smoke/fire handling. As it relates specifically to fire safety, UL 923 specifies: Section 57 Cavity Fire Containment Test: The performance of an appliance subjected to this test shall be considered acceptable if all of the following conditions are met: a) There is no emission of fire, flame, or molten metal outside the appliance nor glowing or ignition of the cheesecloth, tissue paper, or wood surface; b) The fuse rated 3 A does not open; c) Following the test, the appliance complies with the requirements of Leakage Current, Section 33, and Dielectric Voltage-Withstand Test, Section 39, as applicable to primary circuits; and d) Following the test and following 10 c of operation (opening and closing the door), the appliance complies with the requirements in The radiation emission shall not xceed 5mW/cm2. Test Method: Section 57.2 requires that 4 potatoes each weighing between 150g and 200g be placed inside the oven under test and cooked using full microwave power and hot air (if applicable) until the potatoes catch fire. Note: The test must be repeated until it catches fire. During this test, pieces of tissue paper and cheesecloth are placed above, below and around the product to ensure that the fire and/or excessive heat generated is safely contained within the confines of the appliance. As it relates to grease handling, UL KNLZ specifies: UL KNLZ Guide Information Excerpt: These appliances have been evaluated for the limit of 5 mg/m 3 for the emission of grease-laden air to the room ambient in accordance with the recommendations of the National Fire Protection Association Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96, using the EPA-202 test method prescribed for cooking appliances provided with integral recirculating air systems. C:\Windows\Temp\Rar$DI00.000\Fire smoke and grease statement v2_11.doc

19 Page 10.2 Test Method: The UL KNLZ category requires that products must have less than 5.0 mg/m3 of particulate matter emissions during 8 continuous hours of cooking a worst case food product as measured by EPA 202. Note: Our products were tested using full-fat pepperoni pizzas. As it pertains specifically to smoke: Smoke typically consists of visible grease particulate that escapes from a product during operation. Our ovens utilize a recirculating airpath that is catalytic scrubbed, thus the airborne grease is combusted as it crosses our catalyst. Given this, under typical/normal operating conditions, our product does not emit smoke. If you have any issues or specific questions regarding the above, please contact me directly. Best regards, James K. Pool III James K. Pool III Vice President Engineering, TurboChef Technologies, Inc., Ph: james.pool@turbochef.com C:\Windows\Temp\Rar$DI00.000\Fire smoke and grease statement v2_11.doc

20 Page 11.1 NGO SBK Energy.xls NGO ENERGY ESTIMATE ASTM METHOD Changeable Parameters Operating Time 12 Hours Energy Costs $0.11 kwhr Snooze Mode 0.00 Hours Cook Cycles/Day 100 Cooks/Day Typical Cook Time 45 Seconds Do Not Change the following values Time (min) Power (Watts) Cost/Day Balance of Time (hrs) Warm up $ Cooking $ Snooze Idle 0 0 $ Idle $ Total/Day $1.42 Yearly Total/Month $42.46 $ HVAC Requirements Per Operating Time -- Note: Approximations Only Average Energy Cooking And Idle (J) Warmup Energy (J) Total Energy (J) Total average Power (W) Total Environmental Load kbtu/hr Average Cooling Requirement (ton of AC) /12/2009 Confidential James K. Pool

21 Page 12.1 t ur b oc h e f t e chno logies, inc. NGO Oven Surface Temperatures TM The illustrations in this document represent the surface testing data reported for the TurboChef oven model NGO during cooking after two and a half hours of idle at 520 F (271 C), simulating the highest temperature condition. Fahrenheit Measurements TurboChef Technologies, Inc < < DOC-1222 / Rev A / November 2009 Page 1 of 2

22 Page 12.2 Celsius Measurements TurboChef Technologies, Inc < < DOC-1222 / Rev A / November 2009 Page 2 of 2

23 Page 13.1

i5 Ventless Submittal Information

i5 Ventless Submittal Information TurboChef Technologies Inc. i5 Ventless Submittal Information Spec Sheet 1. 1 UL Ventless Label 2. 1 UL Listing 3. 1 UL KNLZ Explained 4. 1 Emissions Test Results 5. 1 Emissions by Product 6.1 Fire and

More information

HhC 2020 Ventless Submittal Information

HhC 2020 Ventless Submittal Information TurboChef Technologies Inc. HhC 2020 Ventless Submittal Information Spec Sheet 1.1 UL Ventless Label 2.1 Notice of Authorization to Apply to UL Mark 3.1 UL Listing 4.1 UL KNLZ Explained 5.1 KNLZ Letter

More information

i3 Ventless Submittal Information

i3 Ventless Submittal Information TurboChef Technologies Inc. i3 Ventless Submittal Information Spec Sheet 1.1 UL Ventless Label 2.1 Notice of Authorization to Apply to UL Mark 3.1 UL Listing 4.1 UL KNLZ Explained 5.1 Emissions Test Results

More information

Fire Ventless Submittal Information

Fire Ventless Submittal Information TurboChef Technologies Inc. Fire Ventless Submittal Information Spec Sheet 1.1 UL Ventless Label 2.1 Notice of Authorization to Apply to UL Mark 3.1 UL Listing 4.1 UL KNLZ Explained 5.1 Emissions by Product

More information

HhB and HhB 2 Ventless Submittal Information

HhB and HhB 2 Ventless Submittal Information TurboChef Technologies Inc. HhB and HhB 2 Ventless Submittal Information Spec Sheet 1.1 UL Ventless Label 2.1 UL Listing 3.1 UL KNLZ Explained 4.1 City of Los Angeles LAPC and LAMC Approval 5.1 cation

More information

HhC 2620 Ventless Submittal Information

HhC 2620 Ventless Submittal Information TurboChef Technologies Inc. HhC 2620 Ventless Submittal Information Spec Sheet 1.1 UL Ventless Label 2.1 Notice of Completion and Authorization to Apply to UL Mark 3.1 4.1 Emissions Test Results UL Listing

More information

C3 Ventless Submittal Information

C3 Ventless Submittal Information TurboChef Technologies Inc. C3 Ventless Submittal Information 1. Spec Sheet 1.1 2. UL Ventless Label 2.1 3. UL Listing 3.1 4. UL KNLZ Explained 4.1 5. C3 Emissions Test Results 5.1 6. 7. 8. Emissions by

More information

Since 1991, TurboChef Technologies, Inc. has pioneered the world of rapid cooking. With innovation and top performance in mind, TurboChef has

Since 1991, TurboChef Technologies, Inc. has pioneered the world of rapid cooking. With innovation and top performance in mind, TurboChef has Since 99, TurboChef Technologies, Inc. has pioneered the world of rapid cooking. With innovation and top performance in mind, TurboChef has redefined cooking efficiency by designing rapid-cook ovens that

More information

EXPRESS SMART COOK SOLUTIONS

EXPRESS SMART COOK SOLUTIONS EXPRESS SMART COOK SOLUTIONS WELCOME TO PRÁTICA Prática Produtos SA, founded in 1991, is the leading manufacturer of commercial food and bakery products in South America. Based in Pouso Alegre, Prática

More information

ventless rapid cook ovens and conveyors

ventless rapid cook ovens and conveyors ventless rapid cook ovens and conveyors The Company Since 99, TurboChef Technologies, Inc. has pioneered the world of rapid cooking. With innovation and top performance in mind, TurboChef has redefined

More information

EPA 202 TEST METHOD: USING THE MODEL RO151FUA, RATED 480 V, 3 phase, 12KW WITH HUMIDITY, COOKING THE BELOW FOOD PRODUCTS AS MEDIA.

EPA 202 TEST METHOD: USING THE MODEL RO151FUA, RATED 480 V, 3 phase, 12KW WITH HUMIDITY, COOKING THE BELOW FOOD PRODUCTS AS MEDIA. 2014-11-24 Mr. Chad Fisher Cres Cor 5925 Heisley Rd. Mentor, OH 44060 United States E-mail: cfisher@crescor.com Reference: Project : 4786532328 P.O. Number: C FISHER 8/6/14 Product: EPA 202 TEST METHOD:

More information

TurboChef Consumables & Accessories U.S. Price List

TurboChef Consumables & Accessories U.S. Price List TurboChef Consumables & Accessories U.S. Price List All items FOB: Carrollton, Texas unless noted otherwise. Consumable and/or accessory orders less than $5,000 will incur a handling fee. Orders shipping

More information

FORZA FORNI 601 N Main St, Brewster, NY

FORZA FORNI 601 N Main St, Brewster, NY 1 Ventilation guide PAVESI OVENS Key Ventilation Facts for Pavesi Ovens All Pavesi Forni SRL ovens are intended to be direct connected to a natural or powered draft chimney system, per NFPA 96. All Pavesi

More information

THE COMPANY. Since 1991, TurboChef Technologies, Inc. has pioneered the world of rapid cooking. With innovation and top performance in

THE COMPANY. Since 1991, TurboChef Technologies, Inc. has pioneered the world of rapid cooking. With innovation and top performance in THE COMPANY Since 99, TurboChef Technologies, Inc. has pioneered the world of rapid cooking. With innovation and top performance in mind, TurboChef has redefined cooking efficiency by designing rapid-cook

More information

TurboChef Oven Price List

TurboChef Oven Price List TurboChef Oven Price List EFFECTIVE NOVEMBER 27, 2017 2011 2017 TurboChef Technologies, Inc. Rapid Cook Oven Price List S ǒ t a Touch Controls with Cloud-based WiFi: $11,020 * Standard Controls: $10,490

More information

SECTION COMMERCIAL-KITCHEN HOODS

SECTION COMMERCIAL-KITCHEN HOODS SECTION 23 38 13 COMMERCIAL-KITCHEN HOODS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in the section that are not applicable and renumber

More information

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300 CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300 FREQUENTLY ASKED QUESTIONS CONCERNING COMMERCIAL COOKING PROTECTION Published by FIRE ENGINEERING DIVISION

More information

Gas and Electric Convection Ovens

Gas and Electric Convection Ovens Gas and Electric Convection Ovens TURBO-FLOW TURBO-FLOW TURBO-FLOW TURBO-FLOW Door enhancements have increased the durability of the door mechanisms Dual-open doors one hand opens and closes both doors

More information

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company OWNER'S MANUAL FRY Holding Unit (FHU) Patent(s) Pending MODELS FHU FHU IMPORTANT INFORMATION, READ BEFORE USE. PLEASE SAVE THESE INSTRUCTIONS. This manual is Copyright 04 Duke Manufacturing Company. All

More information

Owner s Manual. for the turbochef fire oven TurboChef Technologies, Inc.

Owner s Manual. for the turbochef fire oven TurboChef Technologies, Inc. TM Owner s Manual for the turbochef fire oven 2014 TurboChef Technologies, Inc. For further information, call 800.90TURBO or +1 214.379.6000 Original Instructions The information contained in this manual

More information

Owner s Manual FOR THE TURBOCHEF HIGH H BATCH 2

Owner s Manual FOR THE TURBOCHEF HIGH H BATCH 2 TM Owner s Manual FOR THE TURBOCHEF HIGH H BATCH 2 TM RAPID COOK OVEN 2009 TurboChef Technologies, Inc. MODEL SERIAL NUMBER INSTALLED BY INSTALLATION CHECKED BY SERVICE CENTER NAME / NUMBER For service

More information

Rapidchef high-speed combi microwave cooking ovens.

Rapidchef high-speed combi microwave cooking ovens. Rapidchef high-speed combi microwave cooking ovens. Operations Manual The RapidChef speed oven can evenly and consistently cook, bake, roast, toast, brown, and crisp food up to 15 times faster than traditional

More information

APPLICATION FOR EXEMPTION FROM MECHANICAL VENTILATION

APPLICATION FOR EXEMPTION FROM MECHANICAL VENTILATION COUNTY OF MARIN ENVIRONMENTAL HEALTH SERVICES 3501 CIVIC CENTER DRIVE, RM 236 SAN RAFAEL, CA 94903 415.473.6907/ (Fax) 415.473.4120 www.marincounty.org/ehs APPLICATION FOR EXEMPTION FROM MECHANICAL VENTILATION

More information

Technical Report - AM15VL Series Ventless Dishmachines

Technical Report - AM15VL Series Ventless Dishmachines Warewash Engineering Troy, OH 45374-0001 Technical Report - AM15VL Series Ventless Dishmachines In this document: 1. Machine Operation 2. ICC Code Opinions 3. Customer Testing 4. Operational Test Report

More information

Service Manual. for the turbochef fire oven. CAUTION: Read the instructions before using the machine TurboChef Technologies, Inc.

Service Manual. for the turbochef fire oven. CAUTION: Read the instructions before using the machine TurboChef Technologies, Inc. TM Service Manual for the turbochef fire oven CAUTION: Read the instructions before using the machine. 2014 TurboChef Technologies, Inc. For further information, call 800.90TURBO or +1 214.379.6000 Original

More information

Fire Performance of Translucent Systems

Fire Performance of Translucent Systems Fire Performance of Translucent Systems ASTM E-108 Burning Brand Test on Quadwall Class A Approved Light Transmitting Plastics Fire Test Performance Meets Building Code Requirements: Self-Ignition ASTM

More information

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016 VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016 HOODMART 172 REASER COURT ELYRIA, OH 44035 PHONE: (800)-715-1014 FAX: (800)-716-1214 1 THIS PAGE LEFT BLANK INTERNTIONALLY 2 LIMITED

More information

COMMERCIAL KITCHEN FIRE SAFETY

COMMERCIAL KITCHEN FIRE SAFETY COMMERCIAL KITCHEN FIRE SAFETY COMMERCIAL KITCHEN FIRE SAFETY Commercial grade kitchens are a common feature found in senior living communities. Operation of a commercial grade kitchen, many safety considerations

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for fire-extinguishing systems other than water-based fire suppression systems.

More information

Service Manual. for the turbochef high h batch 2TM TurboChef Technologies, Inc.

Service Manual. for the turbochef high h batch 2TM TurboChef Technologies, Inc. TM Service Manual for the turbochef high h batch 2TM rapid cook oven 2009 2010 TurboChef Technologies, Inc. For further information call: Customer Service at 800.90turbo Sales & Marketing at 866.90turbo

More information

Owner s Manual FOR THE TURBOCHEF HIGH H BATCH TM RAPID COOK OVEN

Owner s Manual FOR THE TURBOCHEF HIGH H BATCH TM RAPID COOK OVEN Owner s Manual FOR THE TURBOCHEF HIGH H BATCH TM RAPID COOK OVEN MODEL SERIAL NUMBER INSTALLED BY INSTALLATION CHECKED BY SERVICE CENTER NAME / NUMBER For service or information: WITHIN NORTH AMERICA

More information

Service Manual. for the turbochef double batch rapid cook oven TurboChef Technologies, Inc.

Service Manual. for the turbochef double batch rapid cook oven TurboChef Technologies, Inc. TM Service Manual for the turbochef double batch rapid cook oven 2017 TurboChef Technologies, Inc. For further information, call 800.90TURBO or +1 214.379.6000 Original Instructions The information contained

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE Certificate Number 20180618-R11183 Report Reference R38653-20180615 Issue Date 2018-JUNE-18 Issued to: KINGSPAN INSULATION LLC SUITE 175 2100 RIVEREDGE PKY ATLANTA GA 30328 This

More information

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products Manufacturers Statement of Compliance with NFPA 70, National Electric Code Oberon s suspended ceiling

More information

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

ENVIRO UNIT ENGINEERING MANUAL KES SERIES ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units

More information

Owner s Manual. for the turbochef double batch rapid cook oven TurboChef Technologies, Inc.

Owner s Manual. for the turbochef double batch rapid cook oven TurboChef Technologies, Inc. TM Owner s Manual for the turbochef double batch rapid cook oven 2016 TurboChef Technologies, Inc. For further information, call 800.90TURBO or +1 214.379.6000 Original Instructions The information contained

More information

Integrated Ventilation System

Integrated Ventilation System Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Installation Instructions Part No. 65278 Rev. K Table of Contents Important Safety Instructions... 1 Important Information About

More information

ENGINEERING EVALUATION

ENGINEERING EVALUATION ENGINEERING EVALUATION REPORT NUMBER: 100378137MID-002 ORIGINAL ISSUE DATE: April 26 th, 2011 REVISION AND DATE: Original EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Hanchett

More information

D. Reference Standards (Utilize latest editions available):

D. Reference Standards (Utilize latest editions available): 1.01 Scope of Standard A. This standard provides general requirements of The Sam Houston State University for fireextinguishing systems other than water-based fire suppression systems. This document is

More information

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw Exceeding Military Standards without the Cost Electric Radiator A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw Description An engine s belt driven or direct driven

More information

Indiana WX Oil Furnace Inspection Guide

Indiana WX Oil Furnace Inspection Guide Indiana WX Oil Furnace Inspection Guide Client: Job # : Address: Phone: Client Interview: Oil Dealer: Date of last service: Comments/Billing information: Standard Inspection / Clean and Tune Follow-up:

More information

EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS

EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS ICC-ES Report PMG-1004 Reissued 08/2017 This report is subject to renewal 08/2018 EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS DIVISION: 23 00 00 HEATING, VENTILATING AND AIR CONDITIONING (HVAC)

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

FIRE & LIFE SAFTEY STANDARD

FIRE & LIFE SAFTEY STANDARD Title: Effective Date: 01/01/14 Revised Date: 1/1/14 Code References: Title 16, Chapter 16.16 of the Roseville Municipal Code, NFPA 72 Note: This standard is a summary of Fire Department clarifications

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Eloma Genius T6-11 Gas Combination Oven Test Report FSTC Report # 501311112-R0 Application of ASTM Standard Test Method F2861-10 August 2012 Prepared by: Michael Karsz Denis

More information

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition File E315190 Project 07CA39477 March 5, 2008 REPORT on PROCESS CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS Litre Meter Ltd. Buckinghamshire, England Copyright 2008 Underwriters Laboratories Inc. Underwriters

More information

ITEM # MODEL # NAME # SIS # AIA #

ITEM # MODEL # NAME # SIS # AIA # ITEM # MODEL # NAME # SIS # AIA # Combi Oven 202 267375 (AOS202ETM1) EL.COMBI OVEN(TOUCH) 20 GN 2/1-208V-US Short Form Specification Item No. Unit to be Electrolux Combi TOUCHLINE Oven. The air-osteam

More information

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item Public Comment No. 23-NFPA 96-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM E84, Standard Test Method

More information

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS (630) 620-5750 Fax: (630) 629-2374 www.villageoflombard.org COMMERCIAL HOOD & DUCT SYSTEM PLAN REVIEW REQUIREMENTS International

More information

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd November 29, 2010 Revised: January 10, 2013 Revised: January 18, 2013 Mr. Herbert Wheeler Railtech Ltd. 325 Ave Lee, Baie-D Urf QC H9X 3S3 Canada Our Reference: Subject: R26549/09CA56627 Report of Surface

More information

Site Requirements ADVANTAGE PLUS

Site Requirements ADVANTAGE PLUS Site Requirements ADVANTAGE PLUS Reprocessing System MODEL 2.0 International 1 MEDIVATORS is a registered trademark. MEDIVATORS ADVANTAGE is a trademark of MEDIVATORS Inc. Windows and Windows XP are registered

More information

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd October 05, 2011 Eco-Sol Ltd Mr. Paul Allcock Cardiff House Cardiff Rd Barry, Vale of Glamorgan, CF63 2AW Great Britain Our Reference: Subject: R27181/11CA40094 Report of Surface Burning Characteristics

More information

STR-Series Indirect-Fired Air Turnover Units

STR-Series Indirect-Fired Air Turnover Units STR-Series Indirect-Fired Air Turnover Units Equipment Specifi cations 1.800.589.3691 www.weather-rite.com GAS/OIL HEATING ONLY INDIRECT-FIRED AIR TURNOVER UNIT GUIDE SPECIFICATIONS PART 1 GENERAL [Gas][Oil][Gas/Oil

More information

Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations

Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations District of Lake Country 10150 Bottom Wood Lake Road Lake Country, BC V4V 2M1 t: 250-766-6675 f: 250-766-0200 Inspection

More information

Installation Instructions Wall Ovens

Installation Instructions Wall Ovens Installation Instructions Wall Ovens TESTED IN ACCORDANCE WITH THE LATEST EDITION OF UL858 STANDARD FOR HOUSEHOLD ELECTRIC COOKING APPLIANCES. IMPORTANT 1. Before beginning installation, please thoroughly

More information

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003 MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003 California Conference of Directors of Environmental Health I. Background Proper venting and capture of the gases, heat, grease,

More information

Owner s Manual FOR THE TURBOCHEF TORNADO AND TORNADO 2 TM RAPID COOK OVENS

Owner s Manual FOR THE TURBOCHEF TORNADO AND TORNADO 2 TM RAPID COOK OVENS Owner s Manual FOR THE TURBOCHEF TORNADO AND TORNADO 2 TM RAPID COOK OVENS MODEL SERIAL NUMBER INSTALLED BY INSTALLATION CHECKED BY SERVICE CENTER NAME / NUMBER For service or information: WITHIN NORTH

More information

Operation Manual SA Vent. Models Kona, Pali and Mistral

Operation Manual SA Vent. Models Kona, Pali and Mistral Operation Manual SA Vent Models Kona, Pali and Mistral 765 Westminster Street Providence, Rhode Island 02903 U.S.A. Tel: (401) 273-3300 Fax: (401) 273-3328 www.equipex.com e-mail: service@equipex.com IMPORTANT

More information

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM of 25 7/30/2015 1:35 PM First Revision No. 49-NFPA 17A-2015 [ Detail ] Make the following change to 5.2.1.10.2: 5.2.1.10.2* The manual actuation device shall clearly identify the hazard protected and provide

More information

Heating & Holding Cabinets

Heating & Holding Cabinets K Heating & Holding Cabinets In This Section Heated Cabinet/Proofer K-1...254 Universal Heated Proofer K-2...256 Holding Cabinets Stainless Steel K-3...258 Humidified Holding Cabinets K-4...260 Heated

More information

Mobile Vendors Bulletin

Mobile Vendors Bulletin Mobile Vendors Bulletin NUMBER: 13-01 Amended Jan 18, 2016 PURPOSE City of Penticton Regulations for Mobile Vendors This guideline is intended to provide an overview of the City of Penticton requirements

More information

CHAPTER 5: EXHAUST SYSTEMS

CHAPTER 5: EXHAUST SYSTEMS MOTORS, FANS AND FILTERS 503.1 General. Motors and fans shall be sized to provide the required air movement. Motors in areas that contain flammable vapors or dusts shall be of a type approved for such

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS CLASSIC WALL OVENS FOR MODELS: ECD227, ECD230, ECS127, ECS130, ECS136, ECS227, ECS230, MCD227, MCD230, MCS127, MCS130 MCS227, MCS230, PCD230, PCS130, PCS230 Part No 65030 Rev

More information

EXTINGUISHING SYSTEM DETECTION AND CONTROL

EXTINGUISHING SYSTEM DETECTION AND CONTROL GAP.13.0.1 A Publication of Global Asset Protection Services LLC EXTINGUISHING SYSTEM DETECTION AND CONTROL INTRODUCTION Extinguishing systems require prompt detection systems so they operate quickly and

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS DELTA LIMITED, TYPE WH - MODELS 399B-899B SUGGESTED SPECIFICATIONS Catalog No.: 3500.97B Effective: 04-01-17 Replaces: 11-15-08 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 6000.611 Effective: 10-31-16 Replaces: NEW FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site FIRE CODE PERMIT SPECIAL OCCASION APPLICATION YAKIMA COUNTY FIRE MARSHAL S OFFICE International Fire Code 128 N. 2nd Street, 4th floor, Yakima, WA 98901 - (509) 574-2300 FORM: BFS45A 6/5/18 Minimum Information

More information

OPERATOR S MODEL HCN-5 HHC-136 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

OPERATOR S MODEL HCN-5 HHC-136 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT OPERATOR S M A N U A L HEATED HOLDING CABINET MODEL HCN-5 HHC-136 REGISTER WARRANTY ONLINE AT WWW.HENNYPENNY.COM TABLE OF CONTENTS Section Page Section 1. INTRODUCTION... 1-1 1-1. Heated Holding Cabinet...

More information

High Output Vacuum/Pressure Pump

High Output Vacuum/Pressure Pump High Output Vacuum/Pressure Pump User Guide Catalogue Numbers: WP62 115 60 (115 V, 60 Hz) WP62 220 50 (230 V, 50 Hz, 1.1 A) WP62 100 60 (100 V, 50/60 Hz) Notice The information in this document is subject

More information

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361) C US FILE#:MH48178 MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS 78401 PH: (361)884-9800 WWW.JEANSRESTAURANTSUPPLY.COM UL Standard for Safety for Exhaust Hoods for

More information

Owner s Manual. for the turbochef single batch rapid cook oven TurboChef Technologies, Inc.

Owner s Manual. for the turbochef single batch rapid cook oven TurboChef Technologies, Inc. TM Owner s Manual for the turbochef single batch rapid cook oven 2017 TurboChef Technologies, Inc. For further information, call 800.90TURBO or +1 214.379.6000 Original Instructions The information contained

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Page 1 of 19 Committee Input No. 14-NFPA 33-2013 [ Global Input ] Type your content here... Supplemental Information File Name IndoorDraftforCI.docx Description This committee input would be added to new

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS HI DELTA, TYPE WH - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 3500.932A Effective: 04-01-17 Replaces: 10-31-16 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY A.

More information

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951) Riverside County Fire Department Office of the Fire Marshal 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4777 Fax (951) 955-4886 Technical Policy Title: Plant Processing and Extraction

More information

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard PART 1: GENERAL 1.01 Scope of Standard A. This standard provides general guidance concerning the specific preferences of the University of Texas at Austin for safety equipment used in or in support of

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters Low NOx, Quiet, Efficient, Space-Saving Mighty Therm Lo-NOx Greater energy efficiencies as high as 84% are achieved through

More information

VENTLESS DOOR-TYPE DISHWASHER

VENTLESS DOOR-TYPE DISHWASHER Item # Quantity C.S.I. Section 11400 VENTLESS STANDARD FEATURES Internal condensing system minimizes water vapor Does not require a vent hood Energy recovery Sense-A-Temp 70 F rise electric booster heater.74

More information

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006 Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba

More information

REQUIREMENTS FOR HOOD PLANS

REQUIREMENTS FOR HOOD PLANS DEPARTMENT OF PUBLIC HEALTH Division of Environmental Health REQUIREMENTS FOR HOOD PLANS Submit one (1) set of plans drawn to scale of at least ¼-inch per foot. Plans shall conform to applicable California

More information

Electric Cruise Line Double Broiler w/ Oven Base CLB36S-2-440V CL36B2OLF440

Electric Cruise Line Double Broiler w/ Oven Base CLB36S-2-440V CL36B2OLF440 Electric Cruise Line Double Broiler w/ Oven Base CLB36S-2-440V CL36B2OLF440 Installation and Operation Instructions 2M-W1281 Rev. B 10/26/2011 CLB36S-2-440V SAFETY SYMBOL These symbols are intended to

More information

COUNTERTOP CONVECTION OVENS

COUNTERTOP CONVECTION OVENS COOKING EQUIPMENT SERVING THE FOOD INDUSTRY SINCE 1951 COUNTERTOP CONVECTION OVENS Item: 43217 Model: CE-CN-0021 Item: 43218 Model: CE-CN-0047 Item: 45599 Model: CE-CN-0066 Item: 44307 Model: CE-CN-0004-C

More information

The Enviro-Clean Air Scrubber keeps the Atmosphere Clear and Creates Clean Air

The Enviro-Clean Air Scrubber keeps the Atmosphere Clear and Creates Clean Air EXHAUST FAN Scrubber exhaust filtration system consists of a baffle section with water spray, a coarse filter section and a bag filter section to be installed in line with a grease duct. The enclosure

More information

Cooking Equipment. Who we are

Cooking Equipment. Who we are Who we are SABA is a national restaurant and food service equipment provider with combined experience of 50+ years in the industry. Here at SABA, we do take pride in our customer-centric philosophy and

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

OPERATOR S MODEL HHC-901 HHC-904 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

OPERATOR S MODEL HHC-901 HHC-904 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT OPERATOR S M A N U A L HEATED HOLDING CABINET MODEL HHC-901 HHC-904 REGISTER WARRANTY ONLINE AT WWW.HENNYPENNY.COM TABLE OF CONTENTS Section Page Section 1. INTRODUCTION... 1-1 1-1. Heated Holding Cabinet...

More information

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information UL 2360 Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction General Information UL 2360 - Test Methods for Determining the Combustibility

More information

PIP PCTPA001 Testing of Process Analyzer Systems

PIP PCTPA001 Testing of Process Analyzer Systems January 2016 Process Control PIP PCTPA001 Testing of Process Analyzer Systems PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING SBI Single Burning Item - EN 13823 THE BENCHMARK IN FIRE TESTING FTT Single Burning Item (SBI) The importance of the SBI The European Construction Products Directive requires that all European Member states

More information

Meat Thermometer with Wireless Display model 01185

Meat Thermometer with Wireless Display model 01185 Instruction Manual Meat Thermometer with Wireless Display model 01185 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Features & Benefits... 3 Setup... 4 Using the Thermometer... 4-7 Troubleshooting...

More information

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17 The following list contains a summary of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. 1.1.1.1 (B), (C), & (D)

More information

ELECTRIC DECK OVENS INSTALLATION & OPERATING MANUAL

ELECTRIC DECK OVENS INSTALLATION & OPERATING MANUAL ELECTRIC DECK OVENS INSTALLATION & OPERATING MANUAL MODELS: EDO 2136-1, EDO-42-1, EDO 57-1, EDO 42-3, EDO 57-3 FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS MODEL #85747 WARMING DRAWER MANUAL TABLE OF CONTENTS PAGE # SAFETY INSTRUCTIONS.........2 INSTALLATION INSTRUCTIONS......................3 ISLAND INSTALLATION...3

More information

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

Bench Series Ovens Models 21 / 31 / 51 Operating Manual Heat cycle HEATER SWITCH RECIRC. FAN Quincy Lab, Inc. Bench Series Ovens Models 21 / 31 / 51 Operating Manual Standard Contents (1) Bench Series Oven (2) Adjustable chrome wire shelf (4) Shelf brackets

More information

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR) Instruction Manual For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR) Corning Cat. No. 230V 230V Model No. Product Top Plate Size

More information

User Guide. BlueairMedical FEATURING HEPASILENTª TECHNOLOGY

User Guide. BlueairMedical FEATURING HEPASILENTª TECHNOLOGY User Guide BlueairMedical FEATURING HEPASILENTª TECHNOLOGY Blueair Medical THANK YOU FOR CHOOSING BLUEAIR Ready to start breathing cleaner air? First, read this User Guide to ensure that you use the Blueair

More information

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

28 1/2* 72.4 cm. (*28 1/2  to include hinges.) 41 3/4 106 cm. 27 68.6 cm. 28 1/2* 72.4 cm. (includes hinges.) 28 1/2* 41 3/4 106 cm Commercial Single Load Dryers 28 1/2"* 72.4 cm PRODUCT DIMENSIONS (*28 1/2 " to include hinges.) 28 1/2"* 72.4 cm (*28 1/2 " to include hinges.) Models MDE/MDG21PD MDE/MDG21PS MDE/MDG21PR MDE/MDG21PN 43

More information