GAS & ELECTRIC FRYERS
|
|
- Holly Wright
- 6 years ago
- Views:
Transcription
1 OPTIMUM 700 & 900 GAS & ELECTRIC FRYERS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer - WARNING - Installation and repairs must be carried out by personnel approved by the manufacturer and in accordance with current regulations and standards. If any modifications are made the manufacturer can accept no responsibility whatsoever. These appliances must be used in a well-ventilated area. Read the notice carefully before installation. When handling it, it is imperative to leave the appliance on its base till final installation. 3BE390583NI
2 Page 1 3BE390583NI 07/07 TABLE OF CONTENTS GAS & ELECTRIC FRYERS A) TECHNICAL CHARACTERISTICS... 2 B) TECHNICAL INSTRUCTIONS FOR THE INSTALLER 1. FIRM PLATES GAS FRYERS ELECTRIC FRYERS INSTALLATION: GENERALITIES GENERAL REQUIREMENTS HANDLING UNPACKING ACCESS TO THE COMPONENTS LOCATED BEHIND THE FASCIA INSTALLATION: PUTTING IN PLACE READY-TO-INSTALL TOP COOKING UNITS INSTALLATION: CONNECTIONS ELECTRIC CONNECTION GAS CONNECTION ADAPTATION OF THE EQUIPMENT FROM ONE GAS TO ANOTHER STANDARD GAS FRYER GAS IR FRYERS FR
3 Page 2 3BE390583NI 07/07 A: TECHNICAL CHARACTERISTICS OPTIMUM 700, 18 litre gas fryer P GAS connection ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B706.FR18.G Width x Depth x Height 400 x 730 x 959 Basket 130 x 280 x 240 ½ basket 130 x 135 x 240 CAPACITIES Tank (litres) 18 Basket (kg) 2 ½ basket (kg) 1 Width x Depth x Height 400 x 900 x 1150 WEIGHT (KG) 60 GAS Power (kw) 16.5 G31 Propane 37/50 mbar (kg/h) 1.28 G30 Butane 28/50 mbar (kg/h) 1.30 G20 Natural gas 20 mbar (m 3 /h) 1.75 G25 Natural gas 20/25 mbar (m 3 /h) 1.98 ELECTRICITY Voltage Single-phase 230Va.c. Power (kw) 0.1 HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD Frozen fries 6 x 6 (Practical production) 37 Temp. Precooked fries 2 C (Practical prod.) 44 Poaching fresh fries according to NFD Fresh fries: second cooking phase 30 FUNCTIONING TEMPERATURE 140 to 185 C FUNCTIONING SAFETY 210 C TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm above the floor (thread 15/21 mm) As standard, the appliances are equipped with G 20/20 mbar (and G 25/25 mbar) or another gas on request ELECTRIC CONNECTION Electric outlet at 220 mm above the floor This document is not contractual; Edition 05/2007 3BE0417FT
4 Page 3 3BE390583NI 07/07 OPTIMUM 700, Electric fryer, 6 litre twin tank. Ready-to-install P ELECTRIC connection (Fore a cable with 1.5 m free length) MODEL B-D706.FR6DC Height x Width x Depth 380 x 400 x 730 Basket 130 x 135 x 240 CAPACITIES Tank (litres) 2 x 6 Basket (kg) 0.65 Height x Width x Depth 570 x 400 x 900 WEIGHT (KG) 40 ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 12 Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD x 13 Frozen fries 6 x 6 (Practical production) 2 x 18 Temp. Precooked fries 2 C (Practical prod.) 2 x 23 Poaching fresh fries according to NFD x 15 Fresh fries: second cooking phase 2 x 23 FUNCTIONING TEMPERATURE 100 to 185 C FUNCTIONING SAFETY TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm above the floor This document is not contractual; Edition 07/2007 3BE0418FT
5 Page 4 3BE390583NI 07/07 OPTIMUM 700, Electric fryer, 6 litre twin tanks on free bay P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B706.FR6DC Height x Width x Depth 1007 x 400 x 730 Basket 130 x 135 x 240 CAPACITIES Tank (litres) 2 x 6 Basket (kg) 0.65 Height 1200 Width x Depth 400 x 900 WEIGHT (KG) 50 ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 12 Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTIONN (kg/h) Frozen fries according to NFD x 13 Frozen fries 6 x 6 (Practical production) 2 x 18 Temp. Precooked fries 2 C (Practical prod.) 2 x 23 Poaching fresh fries according to NFD x 15 Fresh fries: second cooking phase 2 x 23 FUNCTIONING TEMPERATURE 100 to 185 C FUNCTIONING SAFETY TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm above the floor. This document is not contractual; Edition 07/2007 3BE0419FT
6 Page 5 3BE390583NI 07/07 OPTIMUM 700, 10 litre electric fryer, ready-to-install P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-D706.FR10 Height 380 Width x Depth 400 x 730 Basket 130 x 135 x 240 CAPACITIES Tank (litres) 10 Basket (kg) 0.85 / 1 Height 570 Width x Depth 400 x 900 WEIGHT (KG) ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 8.1 Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD Frozen fries 6 x 6 (Practical production) 24 Temp. Precooked fries 2 C (Practical prod.) 29 Poaching fresh fries according to NFD Fresh fries: second cooking phase 29 FUNCTIONING TEMPERATURE 100 to 185 C FUNCTIONING SAFETY TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm above the floor This document is not contractual; Edition 05/2007 3BE0420FT
7 Page 6 3BE390583NI 07/07 OPTIMUM 700, 10 litre electric fryer on free bay P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B706.FR10 Height 1010 Width x Depth 400 x 730 Basket 130 x 135 x 240 CAPACITIES Tank (litres) 10 Basket (kg) 0.85 / 1 Height 1200 Width x Depth 400 x 900 WEIGHT (KG) 50 ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 8.1 Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD Frozen fries 6 x 6 (Practical production) 24 Temp. Precooked fries 2 C (Practical prod.) 29 Poaching fresh fries according to NFD Fresh fries: second cooking phase 29 FUNCTIONING TEMPERATURE 100 to 185 C FUNCTIONING SAFETY TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm above the floor This document is not contractual; Edition 05/2007 3BE0421FT
8 Page 7 3BE390583NI 07/07 OPTIMUM 700, 15 litre electric fryer, ready-to-install P P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-D706.FR15 B-D706.FR15DC Height Width x Depth 400 x x 730 Basket 130 x 280 x 240 ½ basket 130 x 135 x 240 CAPACITIES Tank (litres) 13 2 x 13 Basket (kg) 1.25 ½ basket (kg) 0.65 Height x Width x Depth 570 x 400 x x 800 x 900 WEIGHT (KG) ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD x 25 Frozen fries 6 x 6 (Practical production) 36 2 x 36 Temp. precooked fries 2 C (Practical prod.) 45 2 x 45 Poaching fresh fries according to NFD x 30 Fresh fries: second cooking phase 45 2 x 45 FUNCTIONING TEMPERATURE 100 to 185 C FUNCTIONING SAFETY TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm above the floor This document is not contractual; Edition 07/2007 3BE0422FT
9 Page 8 3BE390583NI 07/07 OPTIMUM 700, 15 litre electric fryer on free bay P P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B706.FR15 B-B706.FR15DC Height Width Depth Basket 130 x 280 x 240 ½ basket 130 x 135 x 240 CAPACITY Tank (litres) 13 2 x 13 Basket (kg) 1.25 ½ basket (kg) 0.65 Height Width x Depth 400 x x 900 WEIGHT (KG) ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD x 25 Frozen fries 6 x 6 (Practical production) 36 2 x 36 Temp. precooked fries 2 C (Practical prod.) 45 2 x 45 Poaching fresh fries according to NFD x 30 Fresh fries: second cooking phase 45 2 x 45 FUNCTIONING TEMPERATURE 100 to 185 C FUNCTIONING SAFETY TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm above the floor This document is not contractual; Edition 07/2007 3BE0423FT
10 Page 9 3BE390583NI 07/07 OPTIMUM 700, 18 litre electric fryer P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B706.FR18 Height 1007 Width 400 Depth 730 Basket 130 x 280 x 240 ½ basket 130 x 135 x 240 CAPACITIES Tank (litres) 18 Basket (kg) 2 ½ basket (kg) 1 Width 400 Depth x Height 900 x 1200 WEIGHT (KG) 50 ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 15 Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD Frozen fries 6 x 6 (Practical production) 53 Temp. precooked fries 2 C (Practical prod.) 63 Poaching fresh fries according to NFD Fresh fries: second cooking phase 50 FUNCTIONING TEMPERATURE 140 to 185 C FUNCTIONING SAFETY TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 390 mm above the floor This document is not contractual; Edition 05/2007 3BE0424FT
11 Page 10 3BE390583NI 07/07 OPTIMUM 700, Accessories, fixed 630 high bases CODES Width of appliance A Height Width Depth Center-to-center distance between legs B Width of shelf C Height Width Depth WEIGHT (KG) This document is not contractual; Edition 05/2007 3BE0383FT
12 Page 11 3BE390583NI 07/07 OPTIMUM 700, Accessories, 200 mm high fixed and movable common bases Fixed common bases CODES Width of appliance A Replacing the bases 2 x x x x x Height Width Depth Distance B between legs x x x x 743 Height Width Depth WEIGHT (KG) Movable common bases CODES Width of appliance A Replacing the bases 2 x x x x x Height Width Depth Distance B between legs Height Width Depth WEIGHT (KG) This document is not contractual; Edition 05/2007 3BE0410FT
13 Page 12 3BE390583NI 07/07 OPTIMUM 700 and 900, Accessories, independent filtering trolley P MODEL B- CHAFILT Height 810 Width 590 Depth 616 CAPACITIES Rated capacity (litres) 30 Height 850 Width 650 Depth 700 WEIGHT (KG) ELECTRICITY (Single-phase 230V+T) Power (kw) 230V a.c Max. intensity (A) 230V 3a.c CONSTRUCTION All stainless steel TYPE OF APPLIANCE Fitted with castors ELECTRIC CONNECTION A lead with plug to the network This document is not contractual; Edition 05/2007 3BE0426FT
14 Page 13 3BE390583NI 07/07 OPTIMUM 900, 18 litre gas fryer P GAS connection ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B906.FR18.G Width x Depth x Height 400 x 920 x 959 Basket 130 x 280 x 240 ½ basket 130 x 135 x 240 CAPACITIES (mm) Tank (litres) 18 Basket (kg) 2 ½ basket (kg) 1 Width x Depth x Height 500 x 1030 x 1150 WEIGHT (KG) 60 GAS Power (kw) 16.5 G31 Propane 37/50 mbar (kg/h) 1.28 G30 Butane 28/50 mbar (kg/h) 1.30 G20 Natural gas 20 mbar (m 3 /h) 1.75 G25 Natural gas 20/25 mbar (m 3 /h) 1.98 ELECTRICITY Voltage Single-phase 230Va.c. Power (kw) 0.1 HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD Frozen fries 6 x 6 (Practical production) 37 Pre-cooked fries temp. 2 C (Pract. Prod.) 44 Poaching fresh fries according to NFD Fresh fries: second cooking 30 FUNCTIONING TEMPERATURE 140 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm above the floor (thread 15/21 mm) As standard, the appliances are equipped with G 20/20 mbar (and G 25/25 mbar) or another gas on request. ELECTRIC CONNECTION Electric outlet at 220 mm above the floor. This document is not contractual; Edition 05/2007 3BE0496FT
15 Page 14 3BE390583NI 07/07 P OPTIMUM 900, 25 litre gas fryer P GAS connection ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B906.FR25.G B-B906.FR25DC.G Width x Depth x Height 400 x 920 x x 920 x 959 Basket 130 x 280 x 430 ½ basket 130 x 135 x 430 CAPACITIES (mm) Tank (litres) 25 2 x 25 Basket (kg) 2.5 ½ basket (kg) 1.25 Width x Depth x Height 500 x 1030 x x 1110 x 1150 WEIGHT (KG) GAS Power (kw) G31 Propane 37/50 mbar (kg/h) G30 Butane 28/50 mbar (kg/h) G20 Natural gas 20 mbar (m 3 /h) G25 Natural gas 20/25 mbar (m 3 /h) ELECTRICITY Voltage Single-phase 230Va.c. Power (kw) 0.1 HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD x 26 Frozen fries 6 x 6 (Practical production) 46 2 x 46 Pre-cooked fries temp. 2 C (Pract. Prod.) 55 2 x 55 Poaching fresh fries according to NFD x 30 Fresh fries: second cooking 50 2 x 50 FUNCTIONING TEMPERATURE 140 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm above the floor (thread 15/21 mm) As standard, the appliances are equipped with G 20/20 mbar (and G 25/25 mbar) or another gas on request. ELECTRIC CONNECTION Electric outlet at 220 mm above the floor. Document non contractual; Edition 07/2007 3BE0497FT
16 Page 15 3BE390583NI 07/07 P OPTIMUM 900, 25 litre IR gas fryer P GAS connection ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B906.FR25.HP B-B906.FR25DC.HP Width x Depth x Height 400 x 920 x x 920 x 959 Basket 130 x 280 x 430 ½ basket 130 x 135 x 430 CAPACITIES (mm) Tank (litres) 25 2 x 25 Basket (kg) 2.5 ½ basket (kg) 1.25 Width x Depth x Height 500 x 1030 x x 1110 x 1150 WEIGHT (KG) 160 GAS Power (kw) G31 Propane 37/50 mbar (kg/h) G30 Butane 50 mbar (kg/h) G20 Natural gas 20 mbar (m 3 /h) G25 Natural gas 20/25 mbar (m 3 /h) Power (kw) G30 Butane 28/30 mbar (kg/h) ELECTRICITY Voltage Single-phase 230Va.c. Power (kw) 0.1 HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD x 32 Frozen fries 6 x 6 (Practical production) 56 2 x 56 Pre-cooked fries temp. 2 C (Pract. Prod.) 66 2 x 66 Poaching fresh fries according to NFD x 36 Fresh fries: second cooking 60 2 x 60 FUNCTIONING TEMPERATURE 140 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm above the floor (thread 15/21 mm) As standard, the appliances are equipped with G 20/20 mbar (and G 25/25 mbar) or another gas on request. ELECTRIC CONNECTION Electric outlet at 220 mm above the floor. This document is not contractual; Edition 05/2007 3BE0498FT
17 Page 16 3BE390583NI 07/07 OPTIMUM 900, Electric fryer, 6 litre twin tank ready-to-install P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-D906.FR6DC Height 380 Width x Depth 400 x 920 Basket 130 x 135 x 240 CAPACITIES Tank (litres) 2 x 6 Basket (kg) 0.65 Height 570 Width x Depth 500 x 1030 WEIGHT (KG) 45 ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 12 Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD x 13 Frozen fries 6 x 6 (Practical production) 2 x 18 Pre-cooked fries temp. 2 C (Pract. Prod.) 2 x 23 Poaching fresh fries according to NFD x 15 Fresh fries: second cooking 2 x 23 FUNCTIONING TEMPERATURE 100 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm above the floor. This document is not contractual; Edition 05/2007 3BE0499FT
18 Page 17 3BE390583NI 07/07 OPTIMUM 900, Electric fryer, 6 litre twin tanks on cupboard P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B906.FR6DC Height 1007 Width 400 Depth 920 Basket 130 x 135 x 240 CAPACITIES Tank (litres) 2 x 6 Basket (kg) 0.65 Height 1200 Width x Depth 500 x 1030 WEIGHT (KG) 65 ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 12 Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD x 13 Frozen fries 6 x 6 (Practical production) 2 x 18 Pre-cooked fries temp. 2 C (Pract. Prod.) 2 x 23 Poaching fresh fries according to NFD x 15 Fresh fries: second cooking 2 x 23 FUNCTIONING TEMPERATURE 100 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm above the floor. This document is not contractual; Edition 05/2007 3BE0500FT
19 Page 18 3BE390583NI 07/07 OPTIMUM 900, 10 litre electric fryer, ready-to-install P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-D906.FR10 Height 380 Width 400 Depth 920 Basket 130 x 135 x 240 CAPACITIES Tank (litres) 10 Basket (kg) 1 Height 570 Width 500 Depth 1030 WEIGHT (KG) ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 8.1 Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD Frozen fries 6 x 6 (Practical production) 24 Pre-cooked fries temp. 2 C (Pract. Prod.) 29 Poaching fresh fries according to NFD Fresh fries: second cooking 29 FUNCTIONING TEMPERATURE 100 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet 630 mm above the floor. This document is not contractual; Edition 05/2007 3BE0501FT
20 Page 19 3BE390583NI 07/07 OPTIMUM 900, 10 litre electric fryer on cupboard P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B906.FR10 Height 1010 Width 400 Depth 620 Basket 130 x 135 x 240 CAPACITIES Tank (litres) 10 Basket (kg) 1 Height 1200 Width x Depth 500 x 1030 WEIGHT (KG) ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 8.1 Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD Frozen fries 6 x 6 (Practical production) 24 Pre-cooked fries temp. 2 C (Pract. Prod.) 29 Poaching fresh fries according to NFD Fresh fries: second cooking 29 FUNCTIONING TEMPERATURE 100 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm above the floor. This document is not contractual; Edition 05/2007 3BE0502
21 Page 20 3BE390583NI 07/07 OPTIMUM 900, 15 litre electric fryer ready-to-install P P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-D906.FR15 B-D906.FR15DC Height Width x Depth 400 x x 920 Basket 130 x 280 x 240 ½ basket 130 x 135 x 240 CAPACITIES Tank (litres) 13 2 x 13 Basket (kg) 1.25 ½ basket (kg) 0.65 Height Width x Depth 500 x x 1110 WEIGHT (KG) ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) (Standard / reinforced) Frozen fries according to NFD x 25 Frozen fries 6 x 6 (Practical production) 36 2 x 36 Pre-cooked fries temp. 2 C (Pract. Prod.) 45 2 x 45 Poaching fresh fries according to NFD x 30 Fresh fries: second cooking 45 2 x 45 FUNCTIONING TEMPERATURE 100 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm from the floor. This document is not contractual; Edition 05/2007 3BE0503FT
22 Page 21 3BE390583NI 07/07 OPTIMUM 900, 15 litre electric fryer on cupboard P P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B906.FR15 B-B906.FR15DC Width x Depth x Height 400 x 920 x x 920 x 1010 Basket 130 x 280 x 240 ½ basket 130 x 135 x 240 CAPACITIES Tank (litres) 13 2 x 13 Basket (kg) 1.25 ½ basket (kg) 0.65 Width x Depth x Height 500 x 1030 x x 1110 x 1200 WEIGHT (KG) ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) (Standard / reinforced) Frozen fries according to NFD x 25 Frozen fries 6 x 6 (Practical production) 36 2 x 36 Pre-cooked fries temp. 2 C (Pract. Prod.) 45 2 x 45 Poaching fresh fries according to NFD x 30 Fresh fries: second cooking 45 2 x 45 FUNCTIONING TEMPERATURE 100 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 630 mm above the floor. This document is not contractual; Edition 05/2007 3BE0504FT
23 Page 22 3BE390583NI 07/07 OPTIMUM 900, 18 litre standard electric fryer P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B906.FR18 Width 400 Depth x Height 920 x 1007 Basket 130 x 280 x 240 ½ basket 130 x 135 x 240 CAPACITIES (mm) Tank (litres) 18 Basket (kg) 2 ½ basket (kg) 1 Width 500 Depth x Height 1030 x 1200 WEIGHT (KG) 60 ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 15 Max. intensity (A) 230V 3a.c V 3Na.c HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD Frozen fries 6 x 6 (Practical production) 53 Pre-cooked fries temp. 2 C (Pract. Prod.) 63 Poaching fresh fries according to NFD Fresh fries: second cooking 50 FUNCTIONING TEMPERATURE 140 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 390 mm above the floor. This document is not contractual; Edition 05/2007 3BE0505FT
24 Page 23 3BE390583NI 07/07 P OPTIMUM 900, 25 litre electric fryer P ELECTRIC connection (Foresee a cable with 1.5 m free length) MODEL B-B906.FR25 B-B906.FR25DC Height Width x Depth 400 x x 920 Basket 130 x 280 x 240 ½ basket 130 x 135 x 240 CAPACITIES (mm) Tank (litres) 25 2 x 25 Basket (kg) 2.5 ½ basket (kg) 1.25 Height Width x Depth 500 x x 1110 WEIGHT (KG) ELECTRICITY (Three-phase 400V+N+T) Power (kw) 400V 3a.c Max. intensity (A) 400V 3a.c x 32.5 HOURLY RATED PRODUCTION (kg/h) Frozen fries according to NFD x 50 Frozen fries 6 x 6 (Practical production) 78 2 x 78 Pre-cooked fries temp. 2 C (Pract. Prod.) 90 2 x 90 Poaching fresh fries according to NFD x 58 Fresh fries: second cooking 82 2 x 82 FUNCTIONING TEMPERATURE 140 to 185 C SAFETY WORKING TEMPERATURE 210 C TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 390 mm above the floor. This document is not contractual; Edition 05/2007 3BE0506FT
25 Page 24 3BE390583NI 07/07 OPTIMUM 900, Battery filtering Trolley Height x Width x Depth 514 x 372 x 612 CAPACITIES (mm) Tank (litres) 40 Height x Width x Depth 600 x 450 x 700 WEIGHT (KG) ELECTRICITY (Single-phase 230V a.c.) Power (kw) 230V 3a.c Max. intensity (A) 230V 3a.c OPERATION TEMPERATURE 0 to 200 C TYPE OF APPLIANCE Castor fitted ELECTRIC CONNECTION A cable with a plug to a mains socket (Connect to the filtering unit) Possible (and symmetrical) assemblies B ½B F F F F ½B F F F ½B B F ½B F F F ½B F F: Gas or electric fryer ½B: ½ neutral filtering unit or French fry store B: Other appliance of the Optimum 900 series. WARNING! Supply your layout drawing For the technical characteristics of the fryers, neutral top units and fries warmer units with infrared ramp, refer to the relevant technical documentation. This document is not contractual; Edition 05/2007 3BE0507FT
26 Page 25 3BE390583NI 07/07 OPTIMUM 900, Accessories, fixed 630 high bases CODES Width appliance A Height Width Depth Legs centres B Width of shelf C Height Width Depth WEIGHT (KG) This document is not contractual; Edition 05/2007 3BE0447FT
27 Page 26 3BE390583NI 07/07 OPTIMUM 900, Accessories, common 200 high fixed and movable bases Common fixed bases CODES Width appliance A Replacing the bases 2 x x x x x Height Width Depth Leg centres B x x x x 743 Height Width Depth WEIGHT (KG) Common movable bases CODES Width appliance A Replacing the bases 2 x x x x x Height Width Depth Leg centres B Height Width Depth WEIGHT (KG) This document is not contractual; Edition 05/2007 3BE0476FT
28 Page 27 3BE390583NI 07/07 1. FIRM PLATE 1.1 GAS FRYERS Firm plate The firm plates are fixed on the control board (see the diagrams hereafter). In any correspondence about your equipment, please indicate: - The model number (Model.) - The serial number (Fab.Nr.) - The date (Date). Standard gas fryer Qualidor gas fryer Gas changing plate The box marked with a cross indicates the gas for which the appliance has been adjusted A second plate is fixed near the nameplate, which indicates: - The gas for which the appliance has been adjusted. - The country of destination. Country of destination of the appliance IN CASE OF A CHANGE OF GAS (See Section: Changing the appliance from one gas to another) Modify this plate, and mention the new gas used. Fill in the "Pays" zone with the name of the country where the appliance is installed. NOTE: Both the Gas and Pressure for which the appliance is set must be authorised in the country in question. Check this point in the section: Changing the appliance from one gas to another.
29 Page 28 3BE390583NI 07/07 Location of the plate Location of the plates 1.2 ELECTRIC FRYERS The firm plates are fixed on the lower trimming (See the diagrams hersafter). In any correspondence about your equipment, please indicate: - The model number (Model.) - The serial number (Fab.Nr.) - The date (Date). Firm plate Location of the firm plate Location of the plates
30 Page 29 3BE390583NI 07/07 2. INSTALLATION: GENERALITIES NATURE AND POSITION OF CONNECTIONS See "Technical characteristics" at the beginning of these instructions. 2.1 GENERAL REQUIREMENTS A qualified engineer must carry out the installation, modification or repair of the appliance in a workmanlike manner. These appliances must be installed with sufficient ventilation to prevent the formation of excessive concentrations of substances noxious for the health in the room in which they are installed. The appliance is of TYPE A (not connected to an exhaust duct for combustion products gas appliance). The equipment is not designed to work in an explosive atmosphere. Due to this, it must not be installed in a zone subject to ATEX directive. The required flow rate of new air for combustion is 2 m 3 /h per kw of heat release rate (gas appliance). These units must only be placed against a wall or a partition. The latter must be of non-combustible materials or, if not, must be covered with an appropriate, good insulating and non-combustible material. The manufacturer certifies that the packaging meets the provision 94/62/CE (provision relating to packagings and packaging waste of ) and requests that final installer (and user) observes the rules relating to the removal of the packaging (recycling or reconditioning). In case of equipment on a masonry base (see section "Assembly of equipment on masonry base"), all precautions must be taken by the installer to avoid skidding and dropping of the equipment. In case of mobile equipment, never handle the fryer with oil in the tank: oil must be previously drained. In case of mobile equipment, always handle equipment with precaution to avoid tilting it. Warning! Gas fryers are equipped with a polarised electronic flame control box. When connecting electricity, check that the neutral line is properly connected to the neutral terminal and the phase to the phase. 2.2 HANDLING The appliance should only be handled with adapted lifting equipment. Should the appliance need to be transported, this must be on its original pallet and it must not be stacked on other appliances under any circumstances. If the appliance is to be moved without its pallet, it should be carried and not pulled. 2.3 UNPACKING Before installation, remove the strapping from the appliance. The individual parts are not bolted down. Remove the protective plastic film from the stainless steel parts before heating.
31 Page 30 3BE390583NI 07/ ACCESS TO THE COMPONENTS PLACED BEHIND THE FASCIA - Loosen the fixation screws of the control knobs (gas, electric and water) and remove the knobs. - Unscrew both M5 x 16 screws under the fascia. - Tilt the fascia: Slightly pull downwards 1 then to yourself Put the fascia in locking position: clamp both lugs into the apertures foreseen in the fascia.
32 Page 31 3BE390583NI 07/07 3. INSTALLATION: PUTTING IN PLACE 3.1 READY-TO-INSTALL TOP ASSEMBLY OF CANTILEVER APPLIANCES TO A WALL Drilling pattern The fixation of a bracket must support a tensile strength of 400 dan (2 brackets for a 400, 800, 1000 or 1200 wide appliance). It is recommended, for the fixation of cantilever appliances to a concrete wall, to observe the following points: * The reinforced concrete of the wall must be at least of quality 23 MPA (DTU). * Use HSA-R M 8x75 plugs or equivalent (2 for cooking tops and 6 for cooking units). * For the plugs above, each hole must be drilled to diameter 8 mm and, at least, 65 mm deep. Procedure - Fix the template supplied by two 5 screws to the wall. Check horizontality. Warning! Check this template is really horizontal. 902
33 Page 32 3BE390583NI 07/07 - Drill through the 5 fixation holes of the brackets. Use the upper holes (2 brackets per appliance). Note: In case of impossibility (due to the presence of technical ducts, a metal strengthener in the wall ), drill through the lower holes in the template. - Remove the template. - Increase the bracket fixation holes to diameter 8 and, at least, to 65 mm in depth. - Fix the brackets to the wall. Use HSA-R M 8x75 plugs or equivalent. - Open the brackets to the maximum by means of the centre screw Opened bracket Fixation screw Opening screw - Put the appliances in place on the brackets and lock them. - Put the wall supports under the appliance (2 per appliance). - Adjust alignement in height of the appliances by means of the wall support screw jack Bracket Wall support
34 Page 33 3BE390583NI 07/07 - Fix the appliances between themselves from behind in the way of collectors by one HM5 X 16 screw + ø 5 flat washer. - Fix the appliances between themselves from the front after having removed the front fascia (see paragraph 2.4) with one HM5 X 16 screw + Ø 5 flat washer ASSEMBLY OF APPLIANCES ON A 630 HIGH BASE - Fix the fixation lugs of the ready-to-install tops on the base. Fixation lugs
35 Page 34 3BE390583NI 07/07 - Fix the appliances on the base at the front and back legs with two HM5 x 10 screws + ø 5 flat washers. Caged-nuts are fixed on the bottom of the appliance. - Position the tops on the appliances. Width A of the appliances Distance B between legs Fix the appliances between themselves at the back in the way of the collectors with one HM5 X 16 screw + rondelle Ø 5 flat washer. - Fix the appliances between themselves at the front after having removed the fascia (see paragraph 2.4) with two HM5 X 16 screws + Ø 5 flat washers.
36 Page 35 3BE390583NI 07/ COOKING UNITS ASSEMBLY OF CANTILEVER APPLIANCES TO A WALL Drilling pattern The fixation of a bracket must support a tensile strength of 400 dan (2 brackets per an appliance of 400, 800, 1000 or 1200 in width). It is recommended, for the fixation of cantilever appliances to a concrete wall, to observe the following points: * The reinforced concrete wall must be at least of the quality 23 MPA (DTU). * Use HSA-R M 8x75 plugs or equivalent (2 for the cooking tops and 6 for the cooking units). * For the plugs above, drill holes to diameter 8 mm and at least a minimum depth of 65 mm. Procedure - Fix the lower bearing beam of the appliances against the wall. Warning! The bearing beam must be set horizontal (levelled). - Fix the template supplied to the wall with two 5 screws. Set it horizontal
37 Page 36 3BE390583NI 07/07 - Drill through the 5 fixation holes of the brackets. Use the upper holes (2 brackets per appliance). Note: In case of impossibility (due to the presence of technical ducts, a metal strengthener in the wall ), drill through the lower holes in the template. - Remove the template. - Increase the bracket fixation holes to diameter 8 and, at least, to 65 mm in depth. - Fix the brackets to the wall. Use HSA-R M 8x75 plugs or equivalent. - Open the brackets to the maximum by means of the centre screw Opened bracket Fixation screw Opening screw - Set the appliances in place on the brackets and lock them. Warning! The appliances must rest on the bearing beam.
38 Page 37 3BE390583NI 07/07 - Fix the appliances between themselves at the back in the way of collectors by one HM5 X 16 screw + ø 5 flat washer. - Fix the appliances between themselves at the front after having removed the front fascia (see paragraph 2.4) with two HM5 X 16 screws + Ø 5 flat washers. - Fix the appliances between themselves behind the front legs with a clamp: Left appliance Right appliance a) Place the clamp to the folded sides b) Lock by hand. c) Complete tightening with the HM5 x 60 bolt.
39 3.2.2 ASSEMBLY OF APPLIANCES ON AN INDIVIDUAL BASE Page 38 3BE390583NI 07/07 - Fix the appliances between themselves at the back in the way of collectors with one HM5 X 16 screw + Ø 5 flat washer. - Fix the appliances between themselves at the front after having removed the front fascia (see paragraph 2.4) with two HM5 X 16 screws + Ø 5 flat washers. - Fix the appliances between themsleves behind the front legs with a clamp: Left appliance Right appliance a) Place the clamp to the folded sides b) Lock by hand. c) Complete tightening with the HM5 x 60 bolt.
40 3.2.3 ASSEMBLY OF APPLIANCES ON A COMMON BASE Page 39 3BE390583NI 07/07 - Put an appliance on the base, the back part of the appliance and the base being approximately in alignment. (The base is symmetrical, the back and front parts being identical). - Push the appliance backwards until the hooks made in its bottom slot into the square holes size 25 x 25 foreseen for this purpose. Hook fixation (detailed) Hook Hole - Perform these two operations for each appliance put on the same base. - From front, fix the appliance on the base with two HM 5 x 16 screws + 2 ø 5 flat washers from the underside. - Fix the appliances between themselves in the way of collectors with one HM5 X 16 screw + Ø 5 flat washer. - Fix the appliances between themselves at the front after having removed the front fascia (see paragraph 2.4) with two HM5 X 16 screws + Ø 5 flat washers.
41 Page 40 3BE390583NI 07/07 - Fix the appliances between themselves behind the front legs with a clamp: Left appliance Right appliance a) Place the clamp to the folded sides b) Lock by hand. c) Complete tightening with the HM5 x 60 bolt.
42 3.2.4 ASSEMBLY OF THE APPLIANCES ON A MASONRY BASE Page 41 3BE390583NI 07/07 WARNING! This solution is possible only for fryers without the optional battery filtering and for gas fryers without the optional built-in filtering. Dimension of the masonry base for wall or central stove Wall (side view) Centrally (side view) Stove depth Stove depth Stove depth Am Ac Finished Full tiled base height with tiled front Full tiled base Full tiled base 1 cm/m maximum slope 1 cm/m maximum slope 1 cm/m maximum slope Finished height with tiled front (front view) Lf: Stove width Ls Full tiled base Base dimension Range Am Depth of base as a wall version Ac Depth of base as a central version Ls Base length Finished height, completely tiled on the front Optimum Lf Optimum Lf The technical compartment is compulsory if the switch-off tap, the shut-off valve, or the reducing valve are in the stove. There are two possibilities: 1) Neutral top on a 200 or 400 wide technical compartment. 2) Cupboard foreseen for taps and sized 400 with all possibilities of cooking or neutral tops except induction.
43 Assembly of appliances on a masonry base Page 42 3BE390583NI 07/07 Possibility to lay piping on the front Appliance Base space 2000 Trimming plinth Ventilation Base height at front Put the appliances in place on the masonry base. Note: If the appliances are delivered separately from the base, install the appliances on one or more bases space Connect electrical supply to the appliances (see paragraph 4: Installation: Connections) Assemble the appliances between themselves. - Fix the appliances between themselves at the back in the way of collectors with one HM5 X 16 screw + Ø 5 flat washer. - Fix the appliances between themselves at the front having removed the fascia (see paragraph 2.2.3) with two HM5 X 16 screws + Ø 5 flat washers. Connect gas, water and drainage lines to the appliances. Fit the trimming plinths. One front plinth per space 2000 base and one right and left end trimming plinth per stove, depending on order. - Assemble one or more front plinths with junctions (depending on the quantity of bases) (2 screws per plinth). - Fix one or more front plinths 1 and 2) onto one or more bases (two screws at least per plinth). - Fix the back part (on the end appliances before their final installation) on the base with the hex head screw (3). - Fix the right and left end trimming kits (4) (2 front screws and 1 back screw)
44 4.1 ELECTRIC CONNECTION Page 43 3BE390583NI 07/07 4. INSTALLATION: CONNECTIONS Warning! These appliances are equipped with a polarised electronic flame control box. When connecting electricity, check that the neutral line is connected to the neutral terminal and the phase to the phase GAS FRYER Location of the equipotentiality terminal Electric connection is carried out from the right front side of the appliance, whatever the model. - Remove the cover of the connecting box. - Introduce the cable through the gland. - Tighten the gland. - Connect the wires. - Connect the equipotential link to the terminal foreseen for the purpose. - Put the cover back in place on the connecting box Only use supply cables of the H07 RN-F type with 3 x 2.5 mm 2 section. Foresee an omnipolar shut off device patented for safety of personnel (with a distance between contacts of at least 3 mm when opened). The installation must meet the national rules in force (France: NFC ). The appliance must be connected to the earth. The different electric appliances must also be connected by means of an equipotential line (all metallic structures to the same voltage) by means of a terminal provided for this purpose and located beside the connecting gland. The builder denies all responsibility in the case where the instructions above are not observed.
45 Page 44 3BE390583NI 07/ ELECTRIC FRYERS Ready-to-install fryer Unit type fryer Location of the equipotentiality terminal Location of the equipotentiality terminal Electric connection is carried out from the back of the appliance, whatever the model. - Unscrew the fixation screw of the terminal strip support lug or the terminal box cover. - Tilt the lug towards the left or remove the box. - Introduce the cable through the gland. - Tighten the gland. - Connect the wires. - Put the lug back in place on the cover and fix it. - Connect the equipotential link to the terminal foreseen for the purpose. Only use supply cables of the H07 RN-F type with following section : Voltages FR6DC FR10 FR15 FR15DC FR18 FR25 FR25DC 230V 3 a.c. 4 x 6 mm 2-4 x 6 mm 2-4 x 6 mm V 3N a.c. 5 x 4 mm 2 5 x 4 mm 2 5 x 4 mm 2 5 x 6 mm 2 5 x 4 mm 2 5 x 6 mm 2 5 x 6 mm 2 Foresee an omnipolar shut off device patented for safety of personnel (with a distance between contacts of at least 3 mm when opened). The installation must meet the national rules in force (France: NFC ). The appliance must be connected to the earth. The different electric appliances must also be connected by means of an equipotential line (all metallic structures to the same voltage) by means of a terminal provided for this purpose and located beside the connecting gland. The builder denies all responsibility in the case where the instructions above are not observed.
46 Page 45 3BE390583NI 07/ GAS CONNECTION Check that the appliance adjustments meet the nature and pressure of gas distributed in the plant. (See paragraph 1: Firm plate). Connect the appliance to the gas inlet line by interposing a shut off valve that enables the appliance to be isolated from the other part of the plant. The gas inlet line will be dimensioned so as to minimise the load losses: its diameter will be determined depending on its run (length, number of elbows...) and the total power of the appliance. To check the gas pressure supply of the appliance, it is necessary to connect a water column pressure gauge on a pressure tap placed on the gas unit (gas pressure tap A on the diagram). Pressure tap A The gas pressure so measured must be equal to that indicated on the firm plate for the gas used. (See paragraph 1: Firm plate). Gas connections must meet the standards in force (DTU 61.1) and are to be carried out only by qualified installers. These connections are made to a 1/2" male gas part (see above).
47 Page 46 3BE390583NI 07/07 5. ADAPTATION OF THE APPLIANCE FROM ONE GAS TO ANOTHER Generalities: In the following chapters, the different gases are referenced as per their international codification: G20 G25 G30 G31 NATURAL GAS Group H. (Methane, Lacq gas) NATURAL GAS Group L. (Groningue type gas) BUTANE PROPANE 5.1 STANDARD GAS FRYERS LIST OF AUTHORISED GASES / PRESSURES AS PER CATEGORIES AND COUNTRIES Countries Category Gas Pressure (mbar) Austria II 2H3B/P G G 30 et G Finland G Sweden II 2H3B/P G Denmark G Belgium I 2E+ G 20 / G 25 20/25 I 3+ G 30 / G /37 Germany G 20 / G II 2ELL3B/P G 30 / G I 3P G Spain United Kingdom Italy G Ireland - Portugal II 2H3+ G 30 / G /37 Switzerland Greece I 2H G Spain - Switzerland II 2H3P G G France II 2E+3+ G 20 / G 25 20/25 G 30 / G /37 II 2E+3B/P G 20 / G 25 20/25 G 30 / G II 2E+3P G 20 / G 25 20/25 G Luxemburg II 2E3B/P G G 30 / G II 2E3P G G Netherlands G II 2L3B/P G G II 2L3P G G Norway I 3B/P G G 31 30
48 5.1.2 CHANGEOVER FROM ONE GAS TO ANOTHER: Page 47 3BE390583NI 07/07 Depending on the country foreseen for the installation and the category of the appliance (indicated on the firm plate), the changeover from one gas to another may require 2 operations: CI Change nozzles (pilot burners and burners (See paragraph 5.1.4) CBA Change of the air ring (See paragraph 5.1.4) PROCEDURE: On the firm plate, check: - The category (ies) of the equipment - The gas and pressure for which it is adjusted. In the following table, select: - the country in question - the gas and the category of the equipment (see above) - the gas and pressure for which the equipment is going to be adjusted - Follow and carry out the necessary operations - Replace the adjustment plate and enter in the box the new gas used. COUNTRIES GAS OF ORIGIN (or new gas) NEW GAS (or gas of origin) CATEGORY NECESSARY & AUTHORISED Gas P(mbar) Gas P(mbar) OPERATIONS Austria G G 30 or G II CI CBA 2H3B/P G G Nothing Finland - Sweden G G 30 or G 31 30/30 II CI CBA 2H3B/P Denmark G G Nothing Belgium G G I 2E+ Nothing G G I 3+ CBA Germany G G CI G 20 or G G 30 or G II 2ELL3B/P CI CBA G G CI CBA G G I 3P CI CBA G Change category G (see *) Spain - Switzerland G G 30 or G /30 CI CBA United Kingdom - II 2H3+ Italy Ireland - Portugal G G CBA Spain - Switzerland G G II 2H3P CI CBA France Luxemburg Netherlands G G Nothing G 20 or G 25 20/25 G 30 or G /37 II 2E+3+ CI (G30 CBA) G G CBA G 20 or G 25 20/25 G 30 or G II 2E+3B/P CI CBA G 20 or G 25 20/25 G II 2E+3P CI CBA G G 30 or G II 2E+3B/P CI CBA G G II 2E+3P CI CBA G G 30 or G /30 II CI CBA 2L3B/P G G Nothing G G II 2L3P CI CBA Norway G G I 3B/P Nothing *Change of category to be made only under the responsibility of our Company or our local agent.
49 Page 48 3BE390583NI 07/ GAS FLOW RATES AND POWERS See paragraph 1: TECHNICAL CHARACTERISTICS (Instructions for installation) CHART OF NOZZLES & AIR ADJUSTMENT Fryer FR18 GAS NOZZLES Designation Pressure Qty Diameter d Code Family Type (mbar) (1/100 e ) (mm) Burner Natural G 20/G 25 20/ gas G G 25*** G.P.L G G G 30 or G 31* G 31 ** Pilot burner Natural G 20/G 25 20/25 1 Réf: NE gas G Réf: NE G Réf: NE G.P.L G Réf: K G Réf: K G 30 or G 31* G 31 ** 50 1 Réf: K * Configuration valid only for 50 mbar propane in Austria ** Configuration not valid in Austria *** Configuration valid only in the Netherlands. RA: Air adjustment Air adjustment must be carried out by means of the air adjustment flange based on the d size specified in the previous table. Ø d d Code R O S
50 Page 49 3BE390583NI 07/07 Fryer FR25 GAS NOZZLES Designation Pressure Qty Diameter d Code Family Type (mbar) (1/100 e ) (mm) Burner Natural G 20/G 25 20/ gas G G 25*** G.P.L G G G 30 or G 31* * G 31 ** Pilot burner Natural G 20/G 25 20/25 1 Réf: NE gas G Réf: NE G Réf: NE G.P.L G Réf: K G Réf: K G 30 or G 31* G 31 ** 50 1 Réf: K * Configuration valid only for 50 mbar propane in Austria ** Configuration not valid in Austria *** Configuration valid only in the Netherlands. RA: Air adjustment Air adjustment must be carried out by means of the air adjustment flange based on the d size specified in the previous table. Ø d Ø 40* d Code O 40* Q N P
51 Page 50 3BE390583NI 07/ GAS IR FRYERS FR LIST OF AUTHORISED GASES / PRESSURES AS PER CATEGORIES AND COUNTRIES Countries Category Gas Pressure (mbar) Austria II 2H3B/P G Switzerland G 30 and G Sweden - Denmark I 2H G Finland I 3B/P G 30 / G Belgium G 20 / G 25 20/25 II 2E+3P G I 3+ G 30 / G /37 Germany G 20 / G II 2ELL3B/P G 30 / G I 3P G Ireland United G Kingdom II 2H3P Greece Switzerland G Portugal I 3+ G 30 / G /37 Italy I 2H G I 3+ G 30 / G /37 Spain G II 2H3P G ou 50 I 3B/P G 30 / G France G 20 / G 25 20/25 II 2E+3B/P G 30 / G II 2E+3P G 20 / G 25 20/25 G 31 37/50 I 3+ G 30 / G /37 Luxemburg G II 2E3B/P G 30 / G II 2E3P G G I 3+ G 30 / G /37 Netherlands II 2L3B/P G G 30 / G II 2L3P G G Norway I 3B/P G 30 / G CHANGEOVER FROM ONE GAS TO ANOTHER: Depending on the country foreseen for the installation and the category of the appliance (indicated on the firm plate), the changeover from a gas to another may require 2 operations: CI Change nozzles (pilot burners and burners (See paragraph 5.2.4) RA Change air adjustment to pilot burner nozzle (See paragraph 5.2.4)
GAS & ELECTRIC BRATT PANS
OPTIMUM 700 & 900 GAS & ELECTRIC BRATT PANS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer WARNING Installation and repairs must be carried
More informationGAS & ELECTRIC BRATT PANS
OPTIMUM 700 & 900 GAS & ELECTRIC BRATT PANS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer WARNING Installation and repairs must be carried
More informationGAS & ELECTRIC BOILING PANS
OPTIMUM 700 & 900 GAS & ELECTRIC BOILING PANS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer WARNING Installation and repairs must be carried
More informationELECTRIC PASTA COOKERS
OPTIMUM 700 & 900 ELECTRIC PASTA COOKERS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer - WARNING - Installation and repairs must be carried
More informationGAS FRYERS GRANDE CARTE MANUFACTURER S INSTRUCTIONS. Part A: Technical characteristics Part B: Installation instructions.
GRANDE CARTE GAS FRYERS MANUFACTURER S INSTRUCTIONS Part A: Technical characteristics Part B: Installation instructions - WARNING - Installation and repairs must be carried out by personnel approved by
More informationGAS FR25 IR FRYERS. Grande Carte SPECIFICATIONS CONSTRUCTEUR. Part A: Technical characteristics Part B: Technical instructions for installation
Grande Carte GAS FR25 IR FRYERS SPECIFICATIONS CONSTRUCTEUR Part A: Technical characteristics Part B: Technical instructions for installation - WARNING - Installation and repairs must be carried out by
More informationOPTIMUM 700 PASTA COOKER ELECTRIC BUILDER S SPECIFICATIONS. Part A: Technical characteristics Part B: Technical instructions for the installer
OPTIMUM 700 PASTA COOKER ELECTRIC BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer WARNING Installation and repairs must be carried out by personnel
More informationBOILING PANS GAS & ELECTRICS
PREMIUM BOILING PANS GAS & ELECTRICS MANUFACTURER'S INSTRUCTIONS Part A: Technical data Part B: Installation manual - WARNING - Installation and repairs must be carried out by personnel approved by the
More informationMAESTRO STOVES BUILDER S SPECIFICATIONS MAINTENANCE INSTRUCTIONS MBE12005NM
MAESTRO STOVES Charcoal grill BUILDER S SPECIFICATIONS MAINTENANCE INSTRUCTIONS - WARRANTY - In order to guarantee this equipment, we recommend that you comply with the MANUFACTURER S INSTRUCTIONS in this
More informationMAESTRO STOVES BUILDER S SPECIFICATIONS MAINTENANCE INSTRUCTIONS MBE12006NM
MAESTRO STOVES Gas regulated GN2/1 OVEN BUILDER S SPECIFICATIONS MAINTENANCE INSTRUCTIONS - WARRANTY - In order to guarantee this equipment, we recommend that you comply with the MANUFACTURER S INSTRUCTIONS
More information2 COOK TWO PLATE STOVE MODELS 184F, 185F, 186F & 187F
0063 0558CL1170 2 COOK TWO PLATE STOVE MODELS 184F, 185F, 186F & 187F IMPORTANT READ THESE INSTRUCTIONS CAREFULLY SO AS TO FAMILIARISE YOURSELF WITH THE APPLIANCE BEFORE USE. RETAIN THESE INSTRUCTIONS
More informationSKOTTEL BRAAI LIVE THE BRAAI LIFE. MODEL No 8309T-13. Skottel Braai. Grill2Braai LEV8
USER INSTRUCTIONS SKOTTEL BRAAI MODEL No 8309T-13 Skottel Braai Grill2Braai LIVE THE BRAAI LIFE 503-0399 LEV8 CAUTION For Outdoor use only! This appliance may not be used in an exterior enclosed balcony,
More informationZEST HOOD. Instructions Manual.
ZEST HOOD Instructions Manual www.rangemaster.co.uk INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 6 USE... 14 MAINTENANCE... 16 2 RECOMMENDATIONS AND SUGGESTIONS The
More informationHOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance
Installation Operation Commissioning Maintenance HOT AIR GENERATOR WITH GAS BURNER GGS NA11.45 A 06-2011 04-2011 CONTENTS 1. DESCRIPTION OF THE UNIT 2. INSTALLATION & CONNECTION 3. COMMISSIONING 4. CARE
More informationINDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11
INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this
More informationMerloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /
GB 99-11-03/01 1-18 Index 1 WORKING AND FITTED DIMENSIONS 3 1.1 Oven size 60 cm 3 1.2 Maxioven 4 2 INSTALLING THE FITTED OVEN 5 3 FITTED GAS - INSTALLATION REQUIREMENTS 5 4 FIXING THE OVEN TO THE UNIT
More informationInstallation Instructions
Installation Instructions Outdoor Installation Kit Models AD250 & AW250 Part No. 24097 Qualifications for installation of the kit: You must be able to read and understand all instructions provided with
More informationMHG201 Gas Hob Manual for Installation, Use and Maintenance
MHG201 Gas Hob Manual for Installation, Use and Maintenance 1 Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu
More informationHVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance
HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer
More informationILNAS-EN ISO 10684:2004
Fasteners - Hot dip galvanized coatings (ISO 10684:2004) Éléments de fixation - Revêtements de galvanisation à chaud (ISO 10684:2004) Verbindungselemente - Feuerverzinkung (ISO 10684:2004) 07/2004 National
More informationACCESSORIES EVO700 EVO900
ACCESSORIES EVO700 INDEX ACCESSORIES FOR SPECIFIC FUNCTIONS... 4 Accessories for gas ranges... 4 Accessories for gas boiling top... 6 Accessories for electric ranges... 6 Accessories for induction ranges...
More informationELRO Cooking Island Range 600
Installation and Initial Operating Instructions ELRO Cooking Island Range 600 Date 10.07.2015 Replaces 03.06.2013 Author PM Responsible Doc. No. VAE Sig VAE X101703E Revised 1 Pages 24 Subject to modification
More informationLEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.
LEIHDC70SC - LEIHDC70BB LEIHDC70BC Instructions Manual www.rangemaster.co.uk INDEX EN RECOMMENDATIONS AND SUGGESTIONS...3 CHARACTERISTICS...4 INSTALLATION...5 USE...8 MAINTENANCE...9 2 RECOMMENDATIONS
More information3gb53231b.fm5 Page 12 Friday, April 11, :21 PM
3gb53231b.fm5 Page 12 Friday, April 11, 2003 12:21 PM INSTRUCTIONS FOR USE BEFORE USING THE COOKTOP SUGGESTIONS FOR ENVIRONMENT PROTECTION PRECAUTIONS AND GENERAL ADVICE ENERGY SAVING TIPS CARE AND MAINTENANCE
More information700XP & 900XP accessories
700XP & accessories electrolux 700XP & accessories 3 Index specific functions...3 gas ranges...4 electric ranges...6 induction ranges...7 oven ranges...8 fry tops...9 grills... 11 multifunctional cookers...14
More information700XP & 900XP accessories
700XP & accessories electrolux 700XP & accessories 3 Index specific functions...4 gas ranges...4 gas boiling top HP...6 electric ranges...6 induction ranges...7 oven ranges...8 fry tops...9 grills...
More informationCARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER
CARVER - CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER 1:0 SPECIFICATIONS Water capacity Water connections Water supply 9 litres (2 gallons)
More informationThis document is a preview generated by EVS
TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 16829 August 2016 ICS 13.220.40; 13.230; 53.040.10 English Version Fire and explosion prevention and protection for bucket elevators Prévention
More informationBack space vent (A) Fig mm mm / mm / 16. Fig. 3
TECHNICAL DATA 700 mm - 27 9 / 16 Back space vent (A) 800 mm-31 1 / 2 727.5 mm-28 5 / 8 650 mm-25 9 / 16 34 mm 1 5 / 16 ig. 1 768 mm 30 1 / 4 914 mm 36 671 mm-26 7 / 16 708 mm-27 7 / 8 399 mm 15 11 / 16
More informationInstructions Manual CTB CTB 9407
Instructions Manual CTB 6407 - CTB 9407 INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 5 USE... 7 MAINTENANCE... 8 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions
More informationFourneau. «Chambertin» «Chassagne» «Fontenay» INSTALLER'S MANUAL
Fourneau «Chambertin» «Chassagne» «Fontenay» INSTALLER'S MANUAL Appliances must be installed in a workmanlike manner in accordance with the instructions in this manual and locally applicable regulations.
More informationINSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this
More informationF900 SERIES GAS CHARGRILL G9440, G9460, G9490, G User, installation and servicing instructions T Read these instructions before use
F900 SERIES User, installation and servicing instructions GAS CHARGRILL G9440, G9460, G9490, G94120 Read these instructions before use DATE PURCHASED: MODEL NUMBER: SERIAL NUMBER: DEALER: SERVICE PROVIDER:
More informationThis document is a preview generated by EVS
TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 1187 January 2012 ICS 13.220.50; 91.060.20 Supersedes ENV 1187:2002 English Version Test methods for external fire exposure
More informationFourneau. «Saulieu» «Savigny» «Citeaux» INSTALLER'S MANUAL
Fourneau «Saulieu» «Savigny» «Citeaux» INSTALLER'S MANUAL Appliances must be installed in a workmanlike manner in accordance with the instructions in this manual and locally applicable regulations. This
More informationHORIZONTAL COOKING SERIES: 700 / 900 S.A.V MAINTENANCE & AFTER SALES WORK PPS-3WE711911CH
SERIES: 700 / 900 S.A.V MAINTENANCE & AFTER SALES WORK PPS-3WE711911CH GENERAL Tools Every time you se this symbol it is vital that you have the tool indicated to ensure correct and compliant work is undertaken
More informationThese Appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.
G350/11 and 12 FREESTANDING FRYERS INSTALLATION and SERVICING INSTRUCTIONS These Appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.
More informationInstructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine
GB IT FR DE TR Instructions for use and installation Cooker Hood Istruzioni per l uso e l installazione Cappa Mode d emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube
More informationTable Top Patio Heater
Table Top Patio Heater INSTRUCTION MANUAL MODEL: HPS-B Certified by international recognized standards. The infra-red with heat wave outdoor heater. Variable control gas valve with electric push igniter.
More informationTC MODULE (FFD) (with Gas Hob)
TC MODULE (FFD) (with Gas Hob) Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification
More informationProline GAS HOB Model TCG40IX Instruction Book
Proline GAS HOB Model TCG40IX Instruction Book GB Operating and Installation Instructions Index Technical data and specifications...... 3 Installation...................... 3-6 Ventilation........................
More informationInstallation, operating and maintenance ARIA
Installation, operating and maintenance ARIA Providing indoor climate comfort ARIA-IOM-0909-E GENERAL INFORMATION Foreword This installation and maintenance manual is destined for users of the ARIA range
More informationLibretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções
Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções KSEIV97X-2 INDICE CONSIGLI E SUGGERIMENTI... 4 CARATTERISTICHE...
More informationMULTIPOINT BF Gas Fired Balanced Flue Water Heater
Please leave these instructions with the user MULTIPOINT BF Gas Fired Balanced Flue Water Heater User Operating, Installation and Servicing Instructions 6 720 607 090 (03.12) JS Natural Gas Main Multipoint
More informationSIL EM SIL 24 - SIL 25
INFORMAZIONI COMMERCIALI PER I CONSUMATORI COMMERCIAL INFORMATION FOR THE CONSUMER INFORMATIONS COMMERCIALES POUR LE CLIENT INFORMACIONES COMERCIALES PARA EL CLIENTE HANDELSINFORMATIONEN FÜR DEN KUNDEN
More information900 Series. User manual
GAS DEEP FAT FRYERS 900 Series TYPE: 9FRI/G420, 9FRI/G820 User manual S/N: Valid from:30. 06. 2005 Rev.: 1.0 30.6.2005 Rev. 1. General information... 1 1.1 Symbols used in the manual... 1 1.2 Symbols
More informationUser, Installation and Servicing Instructions. Opus 700 Gas Griddle OG7201, OG7202, OG7203, OG7204, OG7207, OG7208 IS349 ECN3592
User, Installation and Servicing Instructions Opus 700 Gas Griddle OG7201, OG7202, OG7203, OG7204, OG7207, OG7208 IS349 ECN3592 Dear Customer, Thank you for purchasing this Lincat product. This is just
More informationSynergy Grill User & Engineer Installation & Conversion Guide
Synergy Grill 1300 User & Engineer Installation & Conversion Guide 1 Index: Description Page Number/Section Important Information 3 Installation 4-6 / Section 1 Commissioning 6 / Section 2 Converting Gas
More informationHG 675 CX 60 HG 675 CN 60 HG 675 CW 60
HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,
More informationINSTALLATION MANUAL. FlexFuison PLATINUM ELECTRIC COMBI FPE-615 FPE-621 FPE-115 FPE-121 FPE-215 FPE-221
INSTALLATION MANUAL FlexFuison PLATINUM ELECTRIC COMBI FPE-615 FPE-621 FPE-115 FPE-121 FPE-215 FPE-221 Directory of Contents Directory of Contents 1 Introduction 4 1.1 About this manual 4 1.1.1 Explanation
More informationK X V and K X O WALL SERIES HOT AIR GENERATORS USE & MAINTENANCE HANDBOOK
HEAD OFFICE : VIA BIBAN 56 ( Z.I. ) 31030 CARBONERA TREVISO - ITALIA TEL. ++39 0422 445363 FAX ++39 0422 398646 EMAIL = info@bpstecnologie.com K X V and K X O WALL SERIES HOT AIR GENERATORS USE & MAINTENANCE
More informationGas Cooktops (450mm Wide Hobs)
Installation and Operation Manual Gas Cooktops (450mm Wide Hobs) Series RN8450G RNL8450G RNB8450G RNLB8450G RN8900G RNL8900G RNB8900G RNLB8900G Date Purchased Serial Number Dealer Service Provider For
More informationCOMMERCIAL GAS AND ELECTRIC STACKED WASHER/ DRYER INSTALLATION INSTRUCTIONS
COMMERCIAL GAS AND ELECTRIC STACKED WASHER/ DRYER INSTALLATION INSTRUCTIONS MODELS MLG19PD, MLE19PD The installation, including a proper exhaust system, is the responsibility of the owner. LEAVE THESE
More informationOPUS Electric Chip Scuttle OE7109 USER /INSTALLATION INSTRUCTIONS
OPUS Electric Chip Scuttle OE7109 USER /INSTALLATION INSTRUCTIONS Please read the following carefully before using this appliance. Warnings and Precautions Please ensure that all commissioning checks and
More informationINSTRUCTIONS FOR USE AND INSTALLATION CAST IRON GRIDDLE PLATES PSF 400 G / PSF 600 G
INSTRUCTIONS FOR USE AND INSTALLATION CAST IRON GRIDDLE PLATES PSF 400 G / PSF 600 G Made in France April 13 CAST IRON GRIDDLE PLATES PSF 400 G / PSF 600 G Congratulations for the acquisition of this upmarket
More informationGAS SERIES HOT AIR GENERATORS (FLOOR) HANDBOOK MODELS : GAS 20 GAS 25 GAS 29 GAS 40
HEAD OFFICE : VIA BIBAN 56 ( Z.I. ) 31030 CARBONERA TREVISO - ITALIA TEL. ++39 0422 445363 FAX ++39 0422 398646 EMAIL = info@bpstecnologie.com 1312 GAS SERIES HOT AIR GENERATORS (FLOOR) HANDBOOK MODELS
More informationÍST EN :2013. Gildistaka ICS: 75.2
ÍST EN 14678-3:2013 Gildistaka 1.5.2013 ICS: 75.2 LPG equipment and accessories - Construction and performance of LPG equipment for automotive filling stations - Part 3: Refuelling installations at private
More informationPARAGON GAS FRYER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL : PDGF/PDGFP
Page 1 of 13 INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS FRYER MODEL : PDGF/PDGFP Page 2 of 13 IMPORTANT PLEASE READ INSTRUCTIONS FULLY BEFORE USE MODEL PDGF FRYER & PDGFP
More informationHHG610SS 60cm 4 burner gas hob. HHG710SS 70cm 5 burner gas hob
User Manual for your HHG610SS 60cm 4 burner gas hob HHG710SS 70cm 5 burner gas hob NOTE: This User Instruction Manual contains important information, including safety & installation points, which will
More informationThis document is a preview generated by EVS
EESTI STANDARD EVS-EN 14195:2005 Metallprofiilid kipsplaattarindite aluskonstruktsioonide jaoks. Definitsioonid, nõuded ja katsemeetodid Metal framing components for gypsum plasterboard systems - Definitions,
More informationINSTALLER AND OWNER GUIDE
5110831/03 INSTALLER AND OWNER GUIDE Model 808 Electric Heater This guide is intended to help you install and care for your Baxi Fires Division electric heater. Please read carefully before installing
More informationENRGY CURB APPLICATION GUIDE FOR TPO ROOFING SYSTEMS
1. Introduction The ENRGY Curb mounting system is a lightweight, nonpenetrating, roof-integrated, photovoltaic (PV) mounting system designed to maintain roof integrity and maximize power density. This
More informationPC 640 GB. Built-in cooking tables 60 Instructions for installation and use
PC 640 GB Built-in cooking tables 60 Instructions for installation and use Congratualtions on choosing an Ariston appliance, which you will find is dependable and easy to use. We recommend that you read
More informationThis document is a preview generated by EVS
TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 16429 March 2013 ICS 13.040.40 English Version Stationary source emissions - Sampling and determination of hydrogen chloride
More informationINSTRUCTIONS FOR USE AND INSTALLATION CAST IRON GRIDDLE PLATES PSF 400 G / PSF 600 G. Made in France G03291
INSTRUCTIONS FOR USE AND INSTALLATION CAST IRON GRIDDLE PLATES PSF 400 G / PSF 600 G Made in France G03291 April 13 CAST IRON GRIDDLE PLATES PSF 400 G / PSF 600 G Congratulations for the acquisition of
More informationUSER MANUAL EFC60001 EFC70001 EFC90001
USER MANUAL EFC60001 EFC70001 EFC90001 We were thinking of you when we made this product electrolux 3 RECOMMDATIONS AND SUGGESTIONS 5 CHARACTERISTICS 6 INSTALLATION 8 USE 11 MAINTANCE 12 Welcome to the
More informationLight oil / kerosene burner
Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h
More informationThis document is a preview generated by EVS
EESTI STANDARD EVS-EN ISO 4759-1:2001 Tolerances for fasteners - Part 1: Bolts, screws, studs and nuts - Product grades A, B and C Tolerances for fasteners - Part 1: Bolts, screws, studs and nuts - Product
More informationINSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC
AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)
More informationGAS & ELECTRIC FRYERS
OPTIMUM 700 & 900 GAS & ELECTRIC FRYERS BUILDER S SPECIFICATIONS Part C: Instructions for use - WARRANTY - In order to guarantee this equipment, we recommend that you comply with the MANUFACTURER S INSTRUCTIONS
More informationGE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y
GE Monogram Installation Instructions Component Cooktop System Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y Before you begin Read these instructions completely and carefully. IMPORTANT: Save
More informationThis document is a preview generated by EVS
TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 14972 May 2008 ICS 13.220.20 English Version Fixed firefighting systems - Watermist systems - Design and installation Installations
More informationCLGOGUIT
CLGOGUIT5 3663602842217 V10617 1 2 IMPORTANT - Please read carefully the separate safety guide before use. x1 [02] x1 [03] x1 [06] x2 [07] x1 [08] x1 [09] x4 [01] x1 [04] x2 [05] x1 [10] x1 [11] x5 (G30
More informationAssembly instructions
Assembly instructions Important safely instruction 4 Children safety 4 Characteristics of the appliance and installation requirements 5 Installation niche features: built-in 6 Installation niche features:
More informationCOPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN :1999
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM EN 30-2-2 July 1999 ICS 97.040.20 English version Domestic cooking appliances burning gas - Part 2-2: Rational use of energy - Appliances having forced-convection
More informationMULTIPOINT FF Room Sealed Fan-Assisted Water Heater
Please leave these instructions with the user MULTIPOINT FF Room Sealed Fan-Assisted Water Heater User Operating, Installation and Servicing Instructions 6 720 607 160 (04.02) JS Natural Gas Main Multipoint
More informationInstallation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80
Installation & Service Manual Models ALF 20, 30, 40, 50, 60, 80 IMPORTANT! Read all safety instructions before installing, using, or servicing the heater. Installation & servicing should only be carried
More informationCROSS RECESSED RAISED COUNTERSUNK HEAD DRILLING SCREWS WITH TAPPING SCREW THREAD (ISO 15483:1999) IRISH STANDARD I.S. EN ISO 15483:2000.
IRISH STANDARD I.S. EN ISO 15483:2000 ICS 21.060.10 National Standards Authority of Ireland Dublin 9 Ireland CROSS RECESSED RAISED COUNTERSUNK Tel: (01) 807 3800 Tel: (01) 807 3838 HEAD DRILLING SCREWS
More informationMODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE
MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50-2014 If your plans do not allow for the venting system as outlined previously in the installing chimney/vent
More informationOPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual
OPTIM RDINT TUBE HETING SYSTEMS Operation, maintenance and servicing manual CONTENTS GENERL INSTRUCTIONS Section Title Page 1. Preparing the Installation 4 2. Checking the Installation rea 5 3. Flue Connection
More informationType 300 Series Bench Electrode Stabilization Ovens
REPAIR PARTS INSTALLATION INSTRUCTIONS Type 300 Series Bench Electrode Stabilization Ovens *Please read all instructions, paying special attention to all cautions or warnings, before beginning any repairs.
More informationMAINTENANCE AND SERVICE GUIDE
c Dimensions MAINTENANCE AND SERVICE GUIDE System II 80 and 100 Central Heating Fanned Flue Boiler Sizes in mm Flue types: C 12 or 42: horizontal C 32 xx: vertical concentric C 32 xy: Twin flue Boiler
More informationInstallation, Operating and Servicing Instructions
Installation, Operating and Servicing Instructions Opus 800 Gas Boiling Tops OG8003, OG8004 & OG8009 Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number:
More informationThis document is a preview generated by EVS
EESTI STANDARD EVS-EN 1303:2005 Building hardware - Cylinders for locks - Requirements and test methods Building hardware - Cylinders for locks - Requirements and test methods EESTI STANDARDIKESKUS EESTI
More informationCANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS
Congratulations on your purchase! Thank you for choosing a Sirius product. CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS SLTC 97 900 EAN# 9351116001612 SL22 900 EAN# 9351116000660 SL7 1200 EAN# 9351116000813
More informationTECHNICAL INSTRUCTIONS
TECHNICAL INSTRUCTIONS 24-Month Maintenance Kit P/N 58015-02 For BMK2.0 (Nozzle Mix) Description of Document: This TID provides the procedures to perform recommended 24-Month maintenance on the following
More informationCOPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN :1999
EUROPEAN STANDARD EN 50134-2 NORME EUROPÉENNE EUROPÄISCHE NORM May 1999 ICS 13.320 English version Systèmes d'alarme Systèmes d'alarme sociale Partie 2: Déclencheurs Alarm systems - Social alarm systems
More informationINSTALLATION GUIDE GB IE B / ß1
FREESTANDING COOKER OR90 Dual Fuel models INSTALLATION GUIDE GB IE 591554B / 1105508-ß1 11.18 1 SAFETY AND WARNINGS! WARNING! Electrical Shock Hazard Before carrying out any work on the electrical section
More informationDRAFT MANUAL. Fourneau. «Saulieu - Savigny» «Citeaux»
DRAFT MANUAL Fourneau «Saulieu - Savigny» «Citeaux» WARNING : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
More informationInstallation manual. Tumble dryers T4130. Compass Control
Installation manual Tumble dryers T4130 Type N1130 Compass Control Installation manual in original language 487 05 41 61/EN 2011.09.16 Contents 3 Contents Safety precautions... 5 Technical data... 7 Setup...
More informationThis document is a preview generated by EVS
EESTI STANDARD EVS-EN 203-2-4:2005 Gaaskuumutusega toitlustusettevõtteseadmed. Osa 2-4: Erinõuded. Fritüürid Gas heated catering equipment - Part 2-4: Specific requirements - Fryers EESTI STANDARDIKESKUS
More informationThor Gas Char-Broiler Installation and Operation Instructions
Thor Gas Char-Broiler Installation and Operation Instructions Model:,,, IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment. For Warranty
More informationUser and Installation Instructions. Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396
User and Installation Instructions Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396 Please read the following carefully before using this appliance. Warnings and Precautions Please ensure that
More informationOG7302 Salamander Grill
OG7302 Salamander Grill USER, INSTALLATION, SERVICING AND CONVERSION INSTRUCTIONS For use in GB & IE IS370 ECN3280 1 Dear Customer, Thank you for purchasing this Lincat product. This is just one of over
More informationCE GUIDELINE IEC. CENELEC (Comité Européen de Normalisation Electrotechnique European Electrotechnical Standardisation Comitee)
INDUSTRIAL GROUP PRODUCT BROCHURE 2014 CE GUIDELINE CE Mark is the abbreviation of Conformity European and in literature mainly means conformity to European Norms. Any product or any product group carrying
More informationINSTRUCTION MANUAL BUILT-IN HOBS CIR900X
INSTRUCTION MANUAL BUILT-IN HOBS CIR900X ENGLISH 3-19 Thank you for choosing our product. We advise you to read this manual carefully. It contains all necessary instructions for maintaining unaltered the
More informationSýnishorn Fire resistance test for service installations - Part 1: Ventilation ducts
ÍST EN 1366-1:2014 Gildistaka 1.2.2015 ICS: 13.22 Eldþolsprófanir fyrir þjónustustöðvar - Hluti 1: Loftræstistokkar Fire resistance test for service installations - Part 1: Ventilation ducts Staðfestur
More informationREFRIGERATING SYSTEMS AND HEAT
IRISH STANDARD I.S. EN 12693:2008 ICS 23.140 27.080 National Standards Authority of Ireland Northwood, Dublin 9 Ireland Tel: +353 1 807 3800 Fax: +353 1 807 3838 http://www.nsai.ie REFRIGERATING SYSTEMS
More informationThis document is a preview generated by EVS
EESTI STANDARD EVS-EN 12261:2002 Gas meters -Turbine gas meters Gas meters -Turbine gas meters EESTI STANDARDIKESKUS EESTI STANDARDI EESSÕNA NATIONAL FOREWORD Käesolev Eesti standard EVS-EN 12261:2002
More informationILNAS-EN 61882:2016. Hazard and operability studies (HAZOP studies) - Application guide
ILNAS-EN 61882:2016 Hazard and operability studies (HAZOP studies) - Application guide Études de danger et d'exploitabilité (études HAZOP) - Guide d'application HAZOP-Verfahren (HAZOP-Studien) - Anwendungsleitfaden
More information