Operating instructions

Size: px
Start display at page:

Download "Operating instructions"

Transcription

1 EN Operating instructions TopGas classic (12,18,24) Hoval United Kingdom Hoval LTD Northgate Newark Nottinghamshire NG24 1JN Phone: Fax: Hoval Export Hovalwerk AG Austrasse Vaduz Principality of Liechtenstein Phone: Fax: / 00-10/07 Subject to modifications

2 Table of contents / For optimum use of the heating system, read the operating instructions! Important addresses and telephone numbers Key to symbols used System data Calculation basis Safety information Safety precautions Intended purpose Customer service Functional principle of the heating system System start-up Checks prior to start-up Switching on the system Heating system control Operating elements of the boiler control panel / basic control N Operating elements of the heating control RS-OT Operating elements of the heating control TopTronic T/N Check list in case of faults Checking the water level How you can save energy Hoval Service / Sales program...17

3 / For optimum use of the heating system, read the operating instructions! 1. For optimum use of the heating system, read the operating instructions! These instructions will provide you with all the information you need for an optimal use of your heating system. An optimally adjusted heating system can not only save you a lot of grief, but also a lot of money. 1.1 Important addresses and telephone numbers Heating installer: Plumbing installer: Electrical installer: Chimney inspector: Fuel supplier: Key to symbols used i Instruction: Result: Note: Safety information: Warning information: Prompts you to carry out an action Shows the expected reaction to your action Provides important information Indicates an immediate hazard to persons Indicates danger to machines and installations ENERGY Energy saving tip: Provides energy saving information 3

4 1. For optimum use of the heating system, read the operating instructions! / System data To be completed by the installation engineer!! Order no.:... Boiler type:... Heating pump type:... Heating regulator type:... Mixer component type:... Water heater type:... Hot water sensor: Yes No Thermostat: Yes No Gas type: natural gas H natural gas L liquefied gas Neutralization equipment: Yes No Condensate pump: Yes No Outside temperature sensor: Yes No Room temperature sensor: Yes No Room air dependent: Yes No Room air independent: Yes No Number of heating circuits: Heating circuit HC =... Heating circuit MC1 =... Heating circuit MC2 =... Heating curve value HC =... Heating curve value MC1 =... Heating curve value MC2 = Calculation basis Lowest outdoor temperature:... C Heat demand:... kw Max. flow temperature:... C 4

5 / Safety information 2. Safety information In the event of danger! Interrupt the flow of fuel (gas) and cut off the power supply If you smell gas! Do not smoke No open fire Avoid sparks Do not switch on lights or other electric appliances Open windows and doors Close the gas shut off valve Contact the heater company/licensed installer Observe the safety guidelines on the gas counter Observe the safety guidelines of the heater company If you smell exhaust gas! Switch the system off Open all windows and doors Notify a specialist heating firm Fresh air supply Fresh and exhaust air openings must not be closed. Closure of fresh air supply openings may lead to incomplete combustion and in turn to the production of poisonous gases. This does not apply if your system is operated independent of boiler room air. Commissioning of a newly installed system may only be carried out by a qualified installer.the installation control must be completed prior to commissioning -see chapter Safety precautions Checking the water level - see page 15 Always keep the room in which the boiler is ocated clean and turn off the burner before starting the cleaning to avoid any faults due to dusty combustion air. Corrosion prevention: Don t use sprays, solvents, purifying agents, colours, glues etc. close to the boiler. These substances may cause corroision in the boiler and the flue gas pipe. 2.2 Intended use i Intended use: The TopGas boiler may only be operated with the fuels indicated in the Information/ Installation instructions. The heat produced must be carried away by the heating water. All boiler openings must be closed during operation. 5

6 3. Customer service / Customer service i You should read these instructions thoroughly before the system is commissioned! Dear Customer, With the Hoval TopGas you have acquired a product manufactured according to the stateof-the-art and highest quality standards. Please ensure that the delivery is consistent with your order and check it is complete. Also check for possible damage in transit and inform the nearest Customer Service centre if there is any. For insurance reasons it will not be possible to accept any subsequent claims. For the correct installation and operation of your Hoval TopGas, all applicable laws, regulations and standards must be complied with; in particular the regulations of the respective energy supply company. In case of queries, please contact your specialist installer or the nearest Hoval Customer Service centre. Assembly or installation of the heating boiler may only be carried out by trained personnel of an approved installation company. Before starting the boiler for the first time, an installation inspection and approval of the overall installation by the installer are required. To guarantee safe and trouble-free operation, operate your Hoval boiler only according to these operating instructions. The boiler may only be used for its intended purpose and fuels for which it is suitable on the basis of its design and for which it has been approved by Hoval. Do not carry out any changes to the system, otherwise all claims under the guarantee will be invalidated. Conversion kits are to be installed and the installation approved by authorised installers or by the Hoval Customer Service. The reliable and safe functioning of a gas boiler, as well as the achievement of an optimal effectiveness and clean combustion are only possible and guaranteed if the system is maintained and cleaned at least once every year. In the event of a fault or in case of damage, please contact the Hoval Customer Service to inquire about the necessary repairs. In the meantime, shut down the unit to avoid any damage. With the acquisition of a Hoval unit you also obtain a comprehensive guarantee protection, as indicated in the guarantee conditions of the guarantee pass for your unit. This guarantee is, however, dependent on the observance of the operating and installation instructions and on compliance with the applicable legal regulations. Non-compliance with the above will invalidate all liability and warranty claims against Hoval. Provided it is used correctly, your Hoval boiler will ensure you enjoy a well heated home for many years. The Hoval Customer Service If you have any doubts in regard to the operation of your Hoval boiler, or minor faults affect its correct functioning, please contact the nearest Hoval Customer Service centre. A telephone call is often enough when it comes to solving small problems. Our trained Customer Service staff will do everything in their hands to help you. If a fault can not be solved in this way, a service technician will visit you in order to solve the problem. We hope you understand that, except in urgent cases, this is not always immediately possible. Take advantage of the offer of the Hoval Customer Services for extending the service life of your Hoval boiler, and ask for a service agreement. Your Customer Services advisor will be pleased to give you information. You will find the addresses on the last page.. 6

7 / Functional principle of the heating system 4. Functional principle of the heating system Component Gas heating boiler Water heater Function Burns natural gas safely without harming the environment. Removes heat from the exhaust gas generated by combustion and transfers it to the heating water. It holds a reserve of domestic hot water for consumption (e.g. for showering). Boiler control Controls and monitors operation of the heating boiler. Ensures that, whatever the temperature outside, the room temperature is as required in an optimum and fuelefficient manner. Radiators, underfloor heating Delivers the heat from the heating water to the room. Heating pump Pumps the heating water from the boiler to the radiators and back to the boiler, where it is heated up again. Mixer valve Manometer Changes the heater flow temperature by mixing in colder heater return water (water that flows to the radiator), so that the desired room temperature is achieved regardless of the outside temperature. Indicates the water pressure in the heating system. Vent Ensures that only heating water and no air is in the system or heaters. Safety valve Prevents pressure in the system becoming excessive. Membrane expansion vessel Keeps the pressure in the system constant. 7

8 4. Functional principle of the heating system / 5. System start-up / 00 Chimney, flue system Radiator(s) or underfloor heating where fitted Water heater Heating boiler 5. System start-up i Commissioning of a newly installed system may only be carried out by a qualified installer. A full installation check must be completed prior to start-up. - Press On/Off to switch the appliance off (LED dark), water pressure is displayed! - Open the shut-off valve of the heater flow and return. - Open the shut-off valve of the gas line that leads to the boiler - Turn on the main switch outside the boiler room (if available). Frequently the heating system has an additional safety switch that only disable the gas burner. - Before commissioning the TopGas the stench trap (siphon) in the condensate drain pipe must be filled with water. 5.1 Checks prior to start-up Check the water level in the heating system. i The heating system must be filled with water and all the air removed. Observe the regulations regarding antifreeze and water treatment. Open the shut-off valves in the flow and return lines. Check the fresh air supply to the heating system. Check the settings for the operating modes. 5.2 Switching on the system Open the gas valve. Turn on the main switch. Set the boiler control unit to the desired operating mode and temperature. 8

9 / Heating system control 6. Heating system control 6.1 Operating elements of the boiler control panel / basic control N4.3 Normally the user does not need to change the basic control settings. All necessary settings have been adjusted by the installer or at the factory. On/Off button (Appliance Off displays water pressure) in the edition "classic" without function Service display + / - (change values) Reset button Operating mode / target value setting / actual value display During normal operation the operating mode is displayed by the LEDs (DHW / HT) The following can be adjusted by pressing the temperature selection button: - Max. Temperature for heating operation (adjustable by using the -/+ button, the value selected here also limits the target value transmitted via the OT bus) - Target value for warm water (adjustable by using the -/+ button, an overlay with the values from the OT bus is possible) Service button (if this button is pressed during normal operation, the actual value of the current operating mode of the boiler is displayed in the two-digit display) Operating Status Display in the Service Display - Operating Status Off, water pressure display The appliance receives voltage, the heating operation and the DHW mode are switched off, but the freeze protection is active. The actual water pressure, which does not cause a reaction in any of the operating modes, is displayed for information only. Off, no heating requirement The appliance is ready for operation and will be turned on immediately when there is a heating or DHW requirement 0 1 After-Run Time Pump in Heating or Hot Water Operation After operating the boiler in the heating or DHW mode, the pump continues to run. Target Temperature Reached Should the desired target temperature including the potentially added offset be exceeded, the burner turns off. 9

10 6. Heating system control / Self-Test The burner regularly checks the connected sensors. During this self-test, the burner does not execute any other tasks. Ventilation, Exhaust Ventilation During the ventilation and the exhaust phase, the number 3 is shown in the display. Ignition During the ignition process the number 4 is shown in the display. If there is an aborted start, then a new start will be attempted according to the diagram in item 1.h. A total of 4 start attempts are permitted before the unit registers a malfunction Operating Mode Heat During the heating operation the target temperature is shown in the two-digit display. If the service button is pressed during the heating operation, the actual temperature is displayed. Operating Mode Hot Water During the DHW operation the display shows the target temperature. If the service button is pressed during the heating operation, the actual temperature is displayed. Warm Water Heating Operation in Comfort Mode (only TopGas combi) or Freeze Protection If freeze protection is active or if the heat exchanger is heated to a set temperature for the comfort mode, then 7 is shown in the display. 10

11 / Heating system control 6.2 Operating elements of the heating control RS-OT Key Designation Function 2 Daytime room temperature Set the daytime room temperature. 3 Reduced room temperature Set the night time room temperature or reduced heating DHW temperature Rotary pushbutton Information key Heating curve set-up Operating mode selection key Holiday Absence Party Automatic Summer Constant heating Set the domestic hot water temperature. Manual DHW reloading. Change the values by turning. Confirm the values by pressing. Function selection by pressing and turning. Show the operating data on the display. Return to the basic display without saving the values. Set the heating characteristics Select the operating modes Turn off the heating system during the holidays (frost protection) Temporarily switch off heating Extended heating Automatic heating according to the preset heating times = normal heating only DHW; heating off Constant heating mode Reduced heating Constant reduced heating mode Standby System switched off - frost protection activated 11

12 6. Heating system control / 00 Key Designation Function 9 Display The basic display shows the day of the week, date and time of the day, as well as the room temperature Possible readouts: 1 Active heating time 24h 2 Weekday display 3 Display of the active operating mode and the clock programme 4 Time of the day 5 Selected operating mode 6 Date / Day / Month / Year 7 Boiler temperature and room temperature 6.3 Operating elements of the heating control TopTronic T/N 9 (in the wall enclosure) Key Designation Function 2 Daytime room temperature Set the daytime room temperature. 3 Reduced room temperature Set the night time room temperature (reduced heating) DHW temperature Rotary pushbutton Information key Heating curve set-up Set the domestic hot water temperature. Manual DHW reloading. Change the values by turning. Confirm the values by pressing. Function selection by pressing and turning. Show the operating data on the display. Return to the basic display without saving the values. Set the heating characteristics 12

13 / Heating system control Key Designation Function 8 Operating mode selection key Select the operating modes Holiday Absence Party Automatic Turn off the heating system during the holidays (frost protection) Temporarily switch off heating Extended heating Automatic heating according to the preset heating times = normal heating Summer Constant heating 9 Manual mode / emission measurement only DHW; heating off Constant heating mode Reduced heating Constant reduced heating mode Standby System switched off - frost protection activated For heating technician only. 10 Display The basic display shows the day of the week, date and time of the day, as well as the current boiler temperature and room temperature (room station) Possible readouts: 1 Active heating time 24h 2 Weekday display 3 Display of the active operating mode and the clock programme 4 Time of the day 5 Selected operating mode 6 Date / Day / Month / Year 7 Boiler temperature and room temperature Brief operating instructions on the hinged cover Special brief operating instructions are provided with the heating control. 13

14 7. Check list in case of faults / Check list in case of faults Fault Inspect / Cause Fix See page Gas boiler - Is power available - Check fuses. does not start - Check the power plug - Press On/Off button (LED lights up) - Is the gas valve open - Open it - Is the service display blinking - Press the reset button - Contact customer service - Is there too little gas - Open gas valve (service display shows - Contact gas provider blinking 4 or 5) Radiators - Are the valves of the heater flow - Open the flow and return valves do not and return open get warm - Is the On/Off button in the Off - Switch unit on 9 position (LEDs are dark) - Press On/Off button (LED lights up) - Is the timer clock of the TopTronic T - Check according to the set correctly operating manual for the heater control - Check water level and water pressure - Top off the heat. system and bleed off air 15 - Are the radiator valve open - Open the valves - The heater circ. pump is not running - Open the latch screw - Turn the shaft end hard with a screwdriver until the resistance goes away - Mixing valve does not open automatically - Open valve man.; Contact customer service No warm - The load pump is not running - Unscrew the latch screw water - Turn the shaft end hard with a screwdriver until the resistance goes away - Is air in the load pipe - Bleed air manually - Manually activate the automatic bleeder Please note! i In case of faults in operation, please carry out checks in accordance with the above checklist. If you are unable to correct the fault, please call either the installation engineer or the Hoval Customer Services. 14

15 / Checking the water level 8. Checking the water level If the water pressure in the system is too low readable on the manometer (installed externally) or in the two-digit display when the boiler is Off (LED is dark) - contact your installation professional or top off water. Topping off the heating system To fill up or top off your heating system you can use regular drinking water. In some exceptional cases the water quality may not be suitable for use in a heating system (highly corrosive or calcium rich water). If that is the case, please contact a reputable specialist. Instructions Press the On/Off button to turn the appliance off (LED is dark); the water pressure is displayed. The heater flow and return valves must be open. The boiler fill and drain faucet is accessible on the underside of the boiler. Connection between the fill faucet and the water faucet is made by using a hose: - Fill the hose with water before connecting it to the boiler to prevent air from getting into the heating system. - Remove the hose after filling the system to ensure a safe disconnect. Fill the water in slowly while checking the water level at the hydrometer or at the display. After topping off the water, briefly open the bleeder valves until all the air has escaped from the system. 15

16 9. This is how you can save energy! / 00 ENERGY 9. This is how you can save energy! Room temperatures and operating times of the heating system have a decisive influence on the fuel consumption. 1 C reduction in the room temperature setting leads to an economy in fuel consumption of up to 6%. Therefore, please take note of the following tips: Avoid setting room temperatures above 20 C and adjust your heating system accordingly. It is worth turning off the radiators in unused rooms, provided there is no risk of frost and no damage caused by moisture either to the building fabric or its furnishings is to be expected. In the main living rooms, there is frequently heat gain due to body warmth, televisions, fireplaces and also sunshine. These cannot be compensated by a weatherdependent regulatory system. It may be worth installing a remote control (RS 30) or a room sensor or fitting thermostats to the radiators in these rooms. When it is draughty in the house, it is not merely unpleasant; it indicates at the same time that heating energy is being wasted. You therefore save fuel if you... keep windows and doors closed in winter.. close chimney dampers when the fire is out. only operate kitchen and bathroom fans when it is necessary to remove moisture and odours. only ventilate briefly, but frequently. seal doors and windows, to prevent continuous leakage loss. Insulation helps to keep in valuable warmth. Take advantage of all these possibilities and... close window and door shutters at night. make sure that heating pipes and hot water pipes in unheated rooms are properly insulated. As low a radiator temperature as possible will prevent unnecessary heat losses. For this reason, the radiator must always be enabled to give its heat up to the room without hindrance. You should therefore avoid: radiator coverings. window-sills which obstruct heat flow because the outlets are covered. Heating the hot water too offers opportunities for saving. The hot water temperature should be set as low as possible. Experiment to find out the lowest temperature at which there is still enough hot water available. If your system includes a hot water circulating pump, it is worth shutting this down at night by means of a time-switch. 16

17 / Hoval Service / sales program 10. Hoval Service / sales program There are many advantages in favour of having a service agreement Your heating system will always be optimally adjusted this saves heating costs and helps preserve the environment. A high level of operational reliability, as in the course of servicing early warning of possible faults may be recognised and corrected. Optimum settings of your system and the regular maintenance will together guarantee a longer service life for your system. The advantageous all-in price.. The Hoval specialists are wellequipped and will give you good and reliable service. When you give us an order, please call the regional Service Controller, who works in close co-operation with the service engineers in the area. The service call can then be made without delay. You will find we have product ranges which offer you possibilities in all sizes of new builds and renovated buildings. Modern Hoval system engineering with a guaranteed future includes: Heat generation systems Compact heating centres for oil firing, heating boilers for oil- and wood-firing, burners, solar energy production systems (collectors) and heat-pumps for making use of geothermal heat or heat generated by wind and water. Heat recovery and industrial ventilation systems Heat distribution systems and buildings services Water heaters (boilers), radiators, heating walls, convectors, low-temperature radiators, heating and ventilation regulators, circulation pumps and heating oil tanks of both plastic and concrete. 17

18 United Kingdom Hoval LTD Northgate Newark Nottinghamshire NG24 1JN Phone: Fax: Switzerland Hoval Herzog AG General-Wille-Strasse 201 CH-8706 Feldmeilen Telefon Telefax Germany Hoval (Deutschland) GmbH Karl-Hammerschmidt Strasse 45 D Aschheim-Dornach Telefon Telefax Austria Hoval Gesellschaft mbh Hovalstrasse 11 A-4614 Marchtrenk Telefon Telefax Italy Hoval Italia S.r.l. Via per Azzano San Paolo, 26/28 I Grassobbio (BG) Telefono Telefax France Hoval France SAS 335 Avenue de Colmar F Strasbourg Téléphone Téléfax Responsibility for energy and the environment

ENG Operating Instructions

ENG Operating Instructions ENG Operating Instructions Brine/Water and Water/Water Heat Pumps Thermalia (5-45) and (8H-45H) 4 204 743 / 02-06/07 Subject to modifications Important Addresses... 3 Safety Instructions... 4 Heating Control...5-7

More information

Operating instructions

Operating instructions ENG Operating instructions Heating controller TopTronic T Hoval Switzerland Hoval Herzog AG CH-8706 Feldmeilen General-Wille-Strasse 201 Telephone 044 / 925 61 11 Fax 044 / 923 11 39 Hoval Austria Hoval

More information

Operating instructions

Operating instructions ENG Operating instructions Wood burning boiler AgroLyt (20-50) Hoval Export Austrasse 70 9490 Vaduz Principality of Liechtenstein Phone: +423 399 2400 Fax: +423 399 2618 Export@hoval.com Hoval LTD Northgate

More information

Operating Instructions

Operating Instructions EN Operating Instructions Wood burning boiler AgroLyt (20-50) Hoval United Kingdom Hoval Ltd. Northgate Newark Nottinghamshire NG24 1JN Phone +44 1636 67 27 11 Fax +44 1636 67 35 32 Hoval Export Hoval

More information

Operating instructions

Operating instructions EN Operating instructions TopGas (35, 45, 60) To be fi lled in by the heating expert: Order No.: Boiler type: Set to: Natural gas H Natural gas L Liquid gas Heating pump type: Heating regulation type:

More information

Operating constructions

Operating constructions EN Operating constructions Heating controller Top Tronic T Hoval Schweiz Hoval Herzog AG CH-8706 Feldmeilen General-Wille-Strasse 201 Telefon 044 / 925 61 11 Telefax 044 / 923 11 39 Hoval Österreich Hoval

More information

TopGas Wall Hung Condensing Gas Boiler

TopGas Wall Hung Condensing Gas Boiler TopGas Wall Hung Condensing Gas Boiler Output range 30 to 80 kw Why choose TopGas? TopGas wall-hung boilers offer compact and advanced gas heating technology built to the high quality standards you would

More information

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit Operating instructions for the system user VIESMANN With constant temperature or weather-compensated control unit VITODENS 050-W 9/2014 Please keep safe. Safety instructions For your safety Please follow

More information

High-output calorifier Modul-plus

High-output calorifier Modul-plus High-output calorifier Modul-plus Efficient, reliable and economical. The Modul-plus meets the highest standards in terms of continuous hot water production and water hygiene. Modul-plus. Advantages at

More information

ir-range 8G /03.15 Changes reserved.

ir-range 8G /03.15 Changes reserved. U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating

More information

Calorifier/heat pump CombiVal WPE/WPER (300)

Calorifier/heat pump CombiVal WPE/WPER (300) Calorifier/heat pump CombiVal WPE/WPER (300) Heat pump technology for cost-effective water heating. Rapid payback as a result of low power consumption. CombiVal WPE/WPER (300). Advantages at a glance.

More information

Gas condensing boiler (wall mounted) TopGas

Gas condensing boiler (wall mounted) TopGas Gas condensing boiler (wall mounted) TopGas Modern gas condensing technology generates up to 15 % more heat from the consumed energy source. TopGas. Advanced technology attractive and compact. TopGas.

More information

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode Operating instructions for the system user VIESMANN Heating system with Vitotronic 100 control unit for constant temperature mode VITODENS VITOPEND 4/2007 Please keep safe. Safety instructions For your

More information

Operating instructions

Operating instructions Operating instructions Gas-fired condensing boiler Logano plus GB312 For the user Please read carefully before use 7 747 009 296-01/2007 EN Contents 1 For your safety..............................................

More information

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN. Operating instructions VITODENS 111-W. for the system user Operating instructions for the system user VIESMANN Heating system with control unit for constant temperature or weather-compensated mode VITODENS 111-W 4/2012 Please keep safe. Safety instructions For

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

/2010 US/CA

/2010 US/CA 6 720 646 148-11/2010 US/CA (en) For the user User s Instructions Condensing gas boiler Logamax plus GB162-L.B. 80 kw/100 kw Please read thoroughly before operating This manual is available in the English

More information

VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Operating instructions VITODENS 100-W. for the system user Operating instructions for the system user VIESMANN Heating system with control unit for constant temperature or weather-compensated mode VITODENS 100-W 1/2012 Please keep safe. Safety instructions For

More information

UltraOil Condensing Oil Boiler

UltraOil Condensing Oil Boiler UltraOil Condensing Oil Boiler Responsibility for energy and environment Output range 35 to 600 kw Why choose UltraOil? The UltraOil condensing boiler featuring our patented alufer heat exchanger and two-stage

More information

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A... Residential Gas Condensing Boiler Greenstar combi 00 p / 5 p ZWB8-3A... ZWB4-3A... Operating Instructions 708733 (07/04) US/CA Contents Contents Explanation of symbols and safety instructions.......................

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

USERS GUIDE 24, 30. For installation guide see reverse of book

USERS GUIDE 24, 30. For installation guide see reverse of book USERS GUIDE 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

GB24 & GB30. User Manual

GB24 & GB30. User Manual GB24 & GB30 User Manual BOILER OUTPUT To Domestic Hot Water:To Central Heating: GB24/30 Minimum 8.0 kw (27,296 Btu/h) GB24 Maximum 24.2 kw (82,570 Btu/h) GB30 Maximum 30.3 kw (103,384 Btu/h) GB24/30 Minimum

More information

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book USERS GUIDE Esprit eco 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI For the owner Operating manual ecotec plus 937 Gas condensing storage combination boiler GB VUI Contents Appliance characteristics Recommended accessories Contents Appliance characteristics... Recommended

More information

Air/water heat pumps Belaria

Air/water heat pumps Belaria Air/water heat pumps Belaria Economical and ecological energy extraction from ambient air. For new buildings and renovations. Front page: Close-up view of the axial fan in the outdoor unit of the Belaria

More information

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation Operating instructions for system users VIESMANN Heating system with control unit for constant temperature operation VITODENS 100 2/2005 Please keep safe Safety instructions For your safety Please follow

More information

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

User s Operation Instructions & Important Warranty Information

User s Operation Instructions & Important Warranty Information United Kingdom en User s Operation Instructions & Important Warranty Information High-efficiency wall-hung boilers Baxi Avanta Plus 18s - 24s - 30s 24c - 28c - 35c - 39c Please keep these instructions

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

USER GUIDE VOGUE MAX SYSTEM

USER GUIDE VOGUE MAX SYSTEM USER GUIDE VOGUE MAX SYSTEM 15 18 26 32 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

User Instructions For TopTronic RS-30

User Instructions For TopTronic RS-30 User Instructions F TopTronic RS-30 430294ENG-Jun02 Hoval Ltd Nthgate Newark Nottinghamshire NG24 1JN Phone 01636 672711 Fax 01636 673532 2 Index 430294ENG-Jun02 Introduction Introduction... 3 Controls...

More information

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017 24 1 2 23 3 4 5 20 6 I 19 7 18 8 9 15 14 11 13 12 i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book i 24 OFF MAX E STATUS BURNER RESET MIN PRE MIN MAX HEAT PREHEAT

More information

TERMO-Blok TERMO-Extra TERMO-Blok PTV

TERMO-Blok TERMO-Extra TERMO-Blok PTV ELECTRIC BOILERS FOR CENTRAL HEATING TERMO-Blok TERMO-Extra TERMO-Blok PTV Contents 1. Introduction... 1 1.1. Applicable documents... 1 1.2. Retention of documents... 1 1.3. Introduction... 1 1.4. Heating

More information

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG atmocraft VK 654/9-654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG For the owner Operating manual atmocraft Gas heating boiler VK 654/9-654/9 GB Contents Appliance characteristics Contents Appliance characteristics.....................

More information

Logic+ Combi

Logic+ Combi USER GUIDE Logic+ Combi 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions HOME SYSTEM GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 28 10 info@vaillant.de

More information

Operating instruction. Remote control station WCM-FS /

Operating instruction. Remote control station WCM-FS / 83277702 1/22-04 1 User instructions... 4 1.1 User instructions... 4 1.2 User guide... 4 1.2.1 Symbols... 4 1.2.2 Target group... 4 1.3 Guarantee and Liability... 4 2 Safety... 5 2.1 Permissible application...

More information

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USERS GUIDE. LOGIC+ Combi 24, 30, 35 USERS GUIDE LOGIC+ Combi 24, 30, 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

DTG Eco / V130

DTG Eco / V130 ECODENS Gas fired condensing boiler EN User Guide 300010111-001-B Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

Operating instructions

Operating instructions Operating instructions Capriz 2 24c 28c GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information... 4 2 Notes on the documentation...

More information

User Manual for model

User Manual for model User Manual for model RKA 24/8 RKA 24 RKA 28 RKA 34 Wall mounted storage combi boiler premix condensing boiler User instruction CE 0694 RKA 24.8_24_28_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO

More information

Operating instructions

Operating instructions Operating instructions Gas condensing boiler WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

More information

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER Combi C30 & C35 User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER When replacing any part on this appliance, use only spare parts that you can be assured confirm

More information

Gas condensing boiler UltraGas

Gas condensing boiler UltraGas Gas condensing boiler UltraGas Patented alufer for a high efficiency and low emission. 1 UltraGas (15-90) and (125-2000D). Advantages at a glance. The UltraGas condensing boiler with patented alufer heat

More information

Greenstar 12i/24i System

Greenstar 12i/24i System USER INSTRUCTIONS & CUSTOMER CARE GUIDE Greenstar 12i/24i System WALL HUNG GAS-FIRED CONDENSING SYSTEM BOILER FOR SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER THIS BOILER IS USED WITH

More information

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS WARMCAIR Condensing Air & Water Heater Publication No. ZZ 1449-2 September 2016 High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS Warmcair C10DW - G.C. No. 43-417-59 Warmcair C16DW

More information

Operating Instructions

Operating Instructions Operating Instructions Low Emissions and High Efficiency Condensing Oil Boiler DANGER! If these instructions are not followed exactly, a fire or explosion may be caused with serious property damage or

More information

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE USER INSTRUCTIONS & CUSTOMER CARE GUIDE Greenstar 25Si/30Si WALL HUNG GAS-FIRED CONDENSING COMBINATION BOILER FOR SEALED CENTRAL HEATING SYSTEMS & DOMESTIC HOT WATER THIS BOILER IS USED WITH NATURAL GAS

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

Wood-burning boiler CBB. User Guide E

Wood-burning boiler CBB. User Guide E EN Wood-burning boiler User Guide 300008541-001-E . Contents 1 Symbols used...........................................................................3 2 Important recommendations...............................................................3

More information

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER System s30 User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER When replacing any part on this appliance, use only spare parts that you can be assured conform to the

More information

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber User Manual for model RBS 24 series ENERGY Wall mounted instantaneous combi boiler room sealed chamber CE 0694 RBS 24 - SERIE ENERGY - RAD - ING - MAN.UT - 1407.1 - DIGITECH TR - MIAH6 - E04 Technical

More information

Operating instructions

Operating instructions The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...

More information

Range GT GTU C GT 220

Range GT GTU C GT 220 Range GT 120 - GTU C 120 - GT 220 Low temperature fuel oil boiler Oil-fired condensation boiler English 21/09/06 Instructions for use Contents Important recommendations...................................................................3

More information

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502* User's Guide VI.7B.D5.02 2005.10 P20 *VI7BD502* *087R8014* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8014* *VI7BD502* Boiler controller P20 VI.7B.D5.02

More information

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions. User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal

More information

Operating instructions Oil condensing boiler

Operating instructions Oil condensing boiler Operating instructions Oil condensing boiler COB COB-CS Boiler for heating Boiler with stratification cylinder Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49-8751/74-0 Fax +49-8751/741600 Internet:

More information

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller Mounting and Operating Instructions Electronics from SAMSON EB 5610 EN Firmware version 1.40 Edition December 2014 Controller

More information

User instructions DHP-AT

User instructions DHP-AT User instructions DHP-AT VUGFC202 If these instructions are not followed during installation and service, Danfoss A/S liability according to the applicable warranty is not binding. Danfoss A/S retains

More information

Modulating clock thermostat

Modulating clock thermostat EN Digital timer thermosatat Modulating clock thermostat Installation and Service Manual 123189-AB Contents 1 Preface...4 1.1 General...4 2 Location of the installation...5 2.1 Position of the regulator...5

More information

Operating Instructions VITOCROSSAL 300 WARNING WARNING IMPORTANT. Read and save these instructions for future reference. for use by heating contractor

Operating Instructions VITOCROSSAL 300 WARNING WARNING IMPORTANT. Read and save these instructions for future reference. for use by heating contractor Operating Instructions for use by heating contractor Vitocrossal 300 CA3 Series 2.5, 3.0, 3.5, 4.0, 5.0 and 6.0 with Vitotronic 300 GW6C control Gas condensing boiler with weather-compensated control unit

More information

Operating instructions

Operating instructions 6304 0307 04/2005 US For the installer Operating instructions Sealed combustion boiler Logano GA24 SC and atmospheric boiler Logano G24X II/SP If these instructions are not followed exactly, a fire or

More information

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s Great Britain EN High-efficiency wall-hung boilers Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s User s Operation Instructions & Important Warranty Information Please keep these instructions in a safe place.

More information

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h United Kingdom en User s Operation Instructions & Important Warranty Information High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h Please keep these instructions in a safe place.

More information

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Thank you for purchasing our fully-automatic gas-fired tankless water heater. Please completely read this Manual

More information

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler.

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler. Operating instructions For the operator Operating instructions ecotec Gas fired wall hung high efficiency boiler Channel Islands Inhaltsverzeichnis Inhaltsverzeichnis 1 Notes on the documentation...3 1.1

More information

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit 7215 3200-02/2006 GB (EN) For the user Users Manual Gas wall hung Boiler condensing Buderus 500-24/S Please read thoroughly before operating the unit Introduction Please read these instructions and follow

More information

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user Users manual Wall-mounted condensing gas boiler Buderus 800-24/29/43/60 and Buderus 800-24T25/29T25 H/V For the user Please read thoroughly before operating the unit 722 3700 (03/200) GB Preface Introduction

More information

User Manual for model

User Manual for model User Manual for model RKA 24 /20 Wall mounted storage combi boiler premix condensing boiler CE 0694 Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate RKA 24.20 - RAD - ING - MAN.UT - 1309.1

More information

DTG X.. N. Low temperature gas furnace. Instructions for use. English 14/11/2005

DTG X.. N. Low temperature gas furnace. Instructions for use. English 14/11/2005 DTG X.. N Low temperature gas furnace English 14/11/2005 Instructions for use Contents Important recommendations...................................................................3 1 Aeration.................................................................................................3

More information

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C 7215 3500-02/2005 GB(EN) For the user Users manual Wall-mounted condensing gas combi boiler Buderus 500-24/C, 500-28/C Please read thoroughly before operating the unit Introduction Please read these instructions

More information

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB 6 720 648 662-00.1T UNI 7000 F Operating instructions For the user AU/G 2 Contents Contents Contents 2 1 Safety information and explanation of symbols 3 1.1 For your safety 3 1.2 Explanation of symbols

More information

Operating instructions

Operating instructions Operating instructions Control unit Logamatic 4211 For users Read carefully before use 7 747 016 927-03/2008 GB/IE Contents 1 Introduction................................................ 4 2 What you should

More information

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler WARNING: Improper installation, setup, modification, operation or maintenance of the heating system can cause personal injury and property damage. Follow each appliances' instructions precisely. For assistance

More information

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen BioClass HM model. With a suitable

More information

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS Heating Controller SDC District Heating Controller DHC 43 OPERATING INSTRUCTIONS Copyright 2002 Honeywell Inc. EN2H-0220 GE51 R0802 SDC / DHC 43 Operating Instructions EN2H-0220 GE51 R0802 Contents SDC

More information

Operating Instructions

Operating Instructions Operating Instructions Control panel Logamatic 4323 For the user Please read carefully before use 6 720 618 563-11/2008 US/CA Contents 1 Introduction................................................ 4 2

More information

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler rinnai.us 1-800-621-9419 CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler Wall-Mounted, Gas-Fired Boiler For the Conversion from Natural Gas (NG) to Liquid Propane Gas (LPG) MODELS M060C M090C M120C

More information

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers User's Instructions Alpha CD24C/32C Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers For Technical help or for Service call... ALPHA HELPLINE

More information

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No. Ultracom 2 sxi Instructions for Use To be left with the user 12sxi G.C. No. 41-019-12 18sxi G.C. No. 41-019-13 30sxi G.C. No. 41-019-14 High Efficiency Condensing System Boilers www.glow-worm.co.uk TABLE

More information

Baxi Maxflow Combi WM

Baxi Maxflow Combi WM Baxi Maxflow Combi WM Gas Fired Wall Mounted Combination Boiler with Unvented Hot Water Storage Please keep these instructions safe. Should you move house, please hand them over to the next occupier. User

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD User Manual for model RK 18 RK 25 RK 34 Premix condensing boiler User instruction CE 0694 RK 18_25_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD Technical specification by

More information

USER GUIDE LOGIC HEAT H

USER GUIDE LOGIC HEAT H USER GUIDE LOGIC HEAT H 12 15 18 24 30 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS... User Manual Contents 1 DOCUMENT REVISION... 4 2 SOFTWARE VERSION... 4 3 BASIC DESCRIPTION... 4 4 BASIC OVERVIEW OF HYDRAULIC DIAGRAMS... 5 4.1 BOILER NOT CONTROLLED BY THE CONTROLLER:... 5 4.2 BOILER CONTROLLED

More information

User Guide. Promax SL Condensing Central Heating Boiler

User Guide. Promax SL Condensing Central Heating Boiler United Kingdom en User Guide Condensing Central Heating Boiler Promax SL 12-15 - 18-24 Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents

More information

Greenstar 12i system / 24i system

Greenstar 12i system / 24i system Greenstar 12i system / 24i system WALL HUNG GAS-FIRED CONDENSING SYSTEM BOILER FOR SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER THIS APPLIANCE IS FOR USE WITH NATURAL GAS OR LPG (Cat

More information

Operating instructions

Operating instructions Operating instructions Room controller 6 720 618 477-00.1RS Logamatic EMS RC35 programming unit For users Read carefully before use. 6 720 642 272 (10/2009) GB Overview of controls Overview of controls

More information

User's Instructions. Alpha CB50

User's Instructions. Alpha CB50 User's Instructions Alpha CB50 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boiler with Unvented Hot Water Storage (From Boiler Serial No. 27B32500001) For Technical help or for Service

More information

User s Information Manual

User s Information Manual User s Information Manual Gas-Fired Water Boilers With or without Aqua Logic (CWH) Now available Matching High Performance Companion Water Heater (Unit sold separately) If the information in this manual

More information

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler User s Operating Instructions Baxi System 100 HE Plus Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler Please keep these instructions safe. Should you move house, please hand them

More information

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW

More information

User s Information Manual

User s Information Manual User s Information Manual Series 2 Models 1000-2000 MBH Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing

More information

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r. Ultracom cxi High Efficiency Condensing System Boilers Instructions for Use To b e l e f t w i t h t h e u s e r WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

The iqe Boiler Range. Combination and System T Boilers.

The iqe Boiler Range. Combination and System T Boilers. The iqe Boiler Range Combination and System T Boilers www.iqe.co.uk iqe - Max Technology Max Efficiency iqe is a select group of partners that have come together to create a unique product range of highly

More information