Evaporative Condenser. Energy Saving Evaporative Condenser
|
|
- Brooke Jackson
- 6 years ago
- Views:
Transcription
1 EVAP-PAK Evaporative Condenser Energy Saving Evaporative Condenser Temp Tech is the Leader in Industrial Refrigeration
2 Plate Evaporative Condenser Reduces Energy Consumption The Heat Transfer Technology that Reduces Energy Consumption The special Wavy-Flow is well established in the world of Enhance Heat Transfer Technology. Temp Tech is proud to be the first who introduce the Wavy-Flow technology to be used in our Plate Evaporative Condenser. The refrigerant is flew turbulently cause of the wavy-patterned design on our plate heat exchanger and it travels 10 times shorter than the plain tube. This results in 1. High heat transfer efficiency and less pressure drop. 2. Reducing energy consumption due to the lower condensing temperature. 3. Light weight and compactness. Modular System Unlimited Expandability It is flexibly and simply installed with less spare parts. Smallest space required. The system is expandable one by one start from 300,000 kcal/hr (1 unit); 600,000 kcal/hr (2 units); 1,500,000 kcal/hr (5 units). Its expandability is well-suited for all refrigeration plants either small or large scale, for plant renovation or improving better condensing pressure which helps saving energy and extending compressor s lifetime. Our EVAP-PAK requires less space and is lightweight than any other condensers. Therefore the replacement of the existing unit is simple and able to provide higher capacity within the same space. Plate Heat Exchanger The Extreme Capacity With the special pattern Wavy-Flow, the refrigerant is flew turbulantly along the plate which increase lots of condensation coefficient. Our plate is wellcared during the production with skilled engineers and trained welders, plate heat exchangers are also tested under pressure at least 40 bar with accurate instrument for quality assurance. Chemical cleaning is applicable. Therefore we ensure our EVAP- PAK is the most reliable product. Long Life and Less Maintenance Our EVAP-PAK is fully made of SUS304. The self anti-corrosion and well-resistance make our EVAP- PAK suitable for installing at any environment in the world. It is well-suited for all kinds of refrigerants such as Halocarbon, Ammonia or any of NWF (Nature Working Fluid) the future environmental friendly refrigerants. Our Plate Evaporative Condensers are manufactured and well-tested at our standardized factory. They are heavy duty, built-to-last and require less maintenance.the service can be accessible easily with its fully-opened door throughout the unit. With our Quality Control Operation System, we ensure you the quality and the efficiency of our EVAP-PAK.
3 Evap-Pak Evaporative Condenser The advantages of structure of our evaporative condenser are novelty,unique and reasonable.we are the first to use the sepcial structure of oval tube condensing coil and PVC heat-exchanging layer and the air with the same direction with the wate Working principle The vapor evaporate and take away the heat of the refrigerant. During operation, the cooling water is pumped up to the nozzle on the top of condenser and evenly spraying to the outside surface of condensing tubes and forming a water layer. The high temperature refrigerant gas come into the condensing coils from top and condenses by cooling water into liquid and flow out from bottom. Some water absorb the heat and become steam, the rest water drop to the water tank for re-circulation, meanwhile, the fans on the top make wind with speed of 3~5 m/s to speed up the evaporation of the water layer outside the surface of condensing tubes and also cool the dropping water which will get back to spay onto the heat-exchange tubes. The steam is blown out by the blower and the blobs mixed to the steam remain on the dehydrator. The floating valve in the tank control water supplement into the tank automatically. WATER SPRAY SYSTEM CONDENSING COIL FRESH AIR AIR GUIDER WATER TANK Construction features HOT & WET AIR AXIAL FLOW FAN DEHYDRATOR HEAT-EXCHANGE LAYER MAINTAIN PASSAGE We design the machine with advantages of novelty, unique and reasonable. The condensation tubes and all the other metal components inside are hot-dipped galvanized (good anti-corrosion and long lifetime). Special tube arrangement makes the coil much smarter and more coil area in a fixed space to enhance heat-exchange. Patented dehydrator is used to reduce the water consumption. The water spray nozzle is anti-blocked type to ensure even spraying. The axial fans are low noise and large air-flow. The blades are made of aluminum alloy and the motor is damp-proof.
4 Evap-Pak Evaporative Condenser HIGH HEAT TRANFFR EFFICIENCY Wavy - Flow Plate heat exchanger Aerodynamic fan New Model Low pressure loss filler MODULAR DESIGN - SIMPLY EXPANDABLEABLE Self-primer water pump From 1 unit : 300,000 Kcal / hr. To any unit : Nox300,000 Kcal / hr. Evap-Pak Evaporative Condenser 1. Refrigerant : Ammonia ( R717 ), R22 and any halocarbon. 2. Easy maintenance : Simply accessible throughout the unit. 3. Long life: all structure using stainless SUS Compactness : Light weight and requires less space.
5 Gas inlet Liquid outlet Air EVAP-PAK TECHNICAL SPECIFCATION Capacities is for Ammonia at condensing 38ºc / wet bulb 28ºc Modal Capacity Dimension(mm.) Weight (kg) Fan Pump kcal/hr A B C Net Operating No./kw No./kw ECP-300M 300,000 1,280 2,300 3,520 1,080 1,380 1/3.0 1/2.2 ECP-600M 600,000 2,510 2,300 3,520 2,160 2,760 2/3.0 2/2.2 ECP-900M 900,000 3,740 2,300 3,520 3,240 4,140 3/3.0 3/2.2 ECP-1200M 1,200,000 4,970 2,300 3,520 4,320 5,520 4/3.0 4/2.2 ECP-1500M 1,500,000 6,200 2,300 3,520 5,400 6,900 5/3.0 5/2.2 ECP-1800M 1,800,000 7,430 2,300 3,520 6,480 8,280 6/3.0 6/2.2 ECP-2100M 2,100,000 8,660 2,300 3,520 7,560 9,660 7/3.0 7/2.2 ECP-2400M 2,400,000 9,890 2,300 3,520 8,640 11,040 8/3.0 8/2.2 ECP-2700M 2,700,000 11,120 2,300 3,520 9,720 12,420 9/3.0 9/2.2 ECP-3000M 3,000,000 12,350 2,300 3,520 10,800 13,800 10/3.0 10/2.2 Design and specifications subject to change without notice.
6 Model Normal condition heat exchanger (kw.) Outline dimension (mm) L W H h1 h2 Transpo Weight(kg) Fan Wator pump Tube ECCII x22x DN100 DN65 ECCII x DN100 DN65 ECCII x DN100 DN65 ECCII x DN100 DN65 ECCII x DN100 DN65 ECCII x DN100 DN65 ECCII x DN100 DN65 ECCII x DN100 DN65 ECCII x DN100 DN65 ECCII x32x DN100 DN65 ECCII x DN100 DN65 ECCII x DN125 DN65 ECCII x DN125 DN65 ECCII x DN125 DN65 ECCII x DN125 DN65 ECCII x DN125 DM65 ECCII x DN125 DN65 ECCII x DN125 DN65 1. Refrigerant in 2. Refrigerant out 3. Water supply in DN25A 4.Maintain access 5.Overflow DN40A 6.Sewage outfall DN40A Design and specifications subject to change without notice. ort Operating Air Flow M 3 /h Power (kw.) Water volume (L/s) Power (kw.) Ammoni afilled in (kg) connection dimension (mm) Vapour in Liquid out
JCseries EVAPORATIVE CONDENSER. engineering data
JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection
More informationSNOWCOOL SYSTEMS INDIA PVT LTD.
SNOWCOOL SYSTEMS INDIA PVT LTD. PRESENTS LARGEST RANGE OF AIR-COOLED FAN FLUID COOLERS CAPACITIES FLUID FLOW 2 CMH TO 20000 CMH HOT FLUID 35 C TO 195 C CONSTRUCTION VERTICAL OR FLAT BED MONO OR MULTI CELLS
More informationV ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless
More informationHigh Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy
More informationVicot Air Conditioning Co., Ltd. CONTENT
CONTENT I. Introduction 2 II. Absorption Principle 3 III. GAX Absorption Cycle 3 IV. Major Component Description and Function 4 V. Features 4 VI. Performance curve 5 VII. Nomenclature 5 VIII. Technical
More informationSTAINLESS STEEL EVAPORATIVE CONDENSER
Brochure : ECF and ECS ver. 001-0 STAINLESS STEEL EVAPORATIVE CONDENSER with stainless steel coil and structure www.heataway.net STAINLESS STEEL FEATURE Discharge air In 1985, HEATAWAY developed stainless
More informationGeneral Catalogue. FORM SSI - G.C (94)
FORM SSI - G.C (94) www.ssi.co.ir General Catalogue INDEX 09CDF 16DNS 16DES 16JBP 16JBP Air Cooled Condenser Air Cooled Condenser Absorption Chiller Double Effect Direct Fired Absorption Chiller Double
More informationModels: DE-75W/D DE-92W/D DE-105W/D DE-27W/D DE-36W/D DE-46W/D DE-52W/D DE-27W/C DE-36W/C DE-46W/C DE-180W/D DE-225W/D DE-270W/D
Brief introduction: This series of air source heat pump is designed for the common area of ambient temperature between -10 C, to 45 C,. The unit is designed for residential sanitary hot water of bathroom,
More informationCENTRAL SPLIT UNIT UNIC
CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products
More informationModular Air Cooled Scroll Chillers
Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube
More informationTreatment. Compressed Air. Equipment CONTENTS
Compressed Air Treatment Equipment CONTENTS 01 REFRIGERATED AIR DRYER P01 02 DESICCANT AIR DRYER P03 03 COMBINED TYPE AIR DRYER P05 04 OIL REMOVER P05 05 COMPRESSED AIR FILTERS P06 06 AIR RECEIVER TANK
More informationMaximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the.
Bulletin 167CH Engineered to Deliver the Maximum Capacity and Highest Quality to the Worldwide Market - with the Lowest Shipping Costs! International Institute of Ammonia Refrigeration Advanced Technology
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationHot Water Heating Systems
Hot Water Heating Systems Find out more at www.greeonline.com Key Wide Range of Operation Conditions Heating -26 C 46 C Features The Ultra Hot Water system is specifically designed to be flexible in its
More informationShort Questions with Answers APPLIED THERMODYNAMICS(5 TH MECHANICAL) Chapter No-1
Short Questions with Answers APPLIED THERMODYNAMICS(5 TH MECHANICAL) Chapter No-1 1. Define mechanical efficiency in case of an IC engine? [2015w] Ans. Mechanical efficiency of an I.C. engine is defined
More informationMath. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.
HVAC Math The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. Math F. to C. Conversion = (f-32)*(5/9) C. to F. Conversion = C * 9/5 +
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationDVU-HP. Integrated Reversible Heat Pump System
Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Integrated Reversible Heat Pump System 2 Integrated Reversible Heat Pump System
More informationWhat is a Closed circuit Cooling Tower (CCT)?
What is a Closed circuit Cooling Tower (CCT)? Closed circuit Cooling Towers are hybrids that pass the working fluids through a tube bundle, upon which clean water is sprayer and a faninduced draft applied.
More informationHIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER
HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER BIGGER-H SERIES JIAXING MES NEW ENERGY TECHNOLOGY CO.,LTD. High quality- We believe that quality is the best business plan R&D team- Professional R&D
More informationMethod to test HVAC equipment at part load conditions
IPLV Method to test HVAC equipment at part load conditions For water cooled chillers: 100% load ( % hrs) + 75% ( Hrs ) + 50% ( Hrs ) + 25% ( Hrs ) = IPLV value Manufacturer can favor this number by tweaking
More informationProcess glycol chillers
Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic
More informationCONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY
CONDENSING UNITS. AIR COOLED CONDENSER. CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY SERIES: DXCZ MODELS: 171, 201, 221, 251, 271, 351 371, 401, 451, 501, 701 and 721 COOLING CAPACITIES OF: 4,7
More informationNH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN
NH 3 Dual Discharge Evaporator Ammonia Industrial Applications 1-16 Tons MDAN > > U s e d f o r S m a l l t o m e d i u m I n d u s t r i a l A m m o n i a a p p l i c a t i o n s Manufactured with Stainless
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationSlim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump
0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient
More informationPortable Vertical Air-Conditioning and Heating Systems
Portable Vertical Air-Conditioning and Heating Systems Specifications for 10 Ton Units 208 230 volt 7 1 77 77 77 33 Front Side Back 77 71 / 77 Front 33 Side 2 Cabinet Features: Heating and Cooling Data:
More informationCompact design & easy maintenance
Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.
More informationCoil-In-Tank Design: Refrigeration System: Cabinet Construction:
Rite-Temp Manufacturing pioneered the development of refrigerated industrial water chillers in 1948. Since the first Rite-Temp units were introduced, quality engineering and manufacturing has been a key
More informationHi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.
R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification
More informationDemand new standards Semi-welded plate heat exchangers in high pressure applications
Demand new standards Semi-welded plate heat exchangers in high pressure applications Tommy Ångbäck Alfa Laval SCHAFFHAUSEN, 29 th of June 2018 Schaffhausen, 29 th of June 2018 Page 2 Higher pressures demand
More informationPool heating, efficiently
Pool heating, efficiently Swimming Pool Heat Pump Get more enjoyment from your pool with a Midea heat pump pool heater from Chromagen The heat pump advantages: Extends your swimming season by maintaining
More informationTemptek Auxiliary Equipment
Temptek Auxiliary Equipment Mold Temperature Controllers - Water Units VT-275-LX VT Series Mold Temperature Controllers are used to process temperature control to 250 F. These units use an incoloy heater
More informationEasy dry line REFRIGERATION AIR DRYERS. With VSCC exclusive patented variable speed system
Easy dry line REFRIGERATION AIR DRYERS With VSCC exclusive patented variable speed system THE ART OF TREATING COMPRESSED AIR Compressed air supplied by industrial plants if not properly treated contains
More informationSB Series Brazed Plate Heat Exchanger Installation Manual
SB Series Brazed Plate Heat Exchanger Installation Manual HOT COLD Exploded view of Schmidt SB Brazed Plate Heat Exchanger. WARNING Before proceeding with installation and operation read entire manual
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More informationApplication guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort
Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS
More informationNoncycling Refrigerated Air Dryers Range AD 10 to AD 4000
Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000 Section 10 Bulletin A -7 Pneumatech is proud to offer this range of reliable and innovative refrigerated air dryers. These dryers are a cost effective
More informationBe sustainable while protecting your business
Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair
More informationProducts catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES
Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES 1 1 2 3 Once again, the Energy Panel team has put all their excitement and enthusiasm to create this new publication. We want to make
More informationSWIMMING POOL HEAT PUMPS
WHAT IS A POOL HEAT PUMP? Swimming pool heat pumps extract the heat stored in the ambient air and transfer it to water. It increases the water temperature to reach the desired level. Comparatively, it
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationHVAC-R INDUSTRIAL EQUIPMENT AUTOMOTIVE AND COMERCIAL VEHICLES RAILWAY EQUIPMENT CONSTRUCTION AND MINING EQUIPMWENT AGRICULTURAL AND FORESTRY EQUIPMENT
RAAL CONDENSERS and EVAPORATORS with extruded tubes and manifolds Tubes & manifolds different types of extruded tubes (multi channel) 1, 2, 3 or more rows of tubes mounted in parallel Core thicknesses
More informationCROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)
CROSSFLOW FILM FILL PACKAGE COOLING TOWER Number 11-40-01 TYH SERIES LOW NOISE - ENERGY SAVINGS Thermal-Cell Sdn Bhd (155-M) TYH SERIES Rectangular Cross Flow Cooling Tower is more superior on its motor,
More informationXLP2 Evaporative Condensers
Form 140.920 SED (NOV 2009) SPECIFICATIONS - ENGINEERING DATA - DIMENSIONS File: EQUIPMENT MANUAL - Section 140 Replaces: 140.920 SED (JUL 2009) Dist: 1, 1a, 1b, 1c, 4, 4b, 4c XLP2 Evaporative Condensers
More informationLifting Plants Product Overview
Wilo-DrainLift Con Duty chart (-pole, 5 Hz) 5 Wilo-DrainLift Con Lifting Plants Product Overview Wilo-DrainLift Lifting Plants Condensate lifting plants Removal of condensate, can be used in Condensing
More informationAtlas Copco After-coolers, water separators and drains HD 4-96 & 8-650, WSD & WD 80/EWD
2935 0838 Printed in Belgium Subject to alteration without prior notice. Never use compressed air as breathing air without prior purification in accordance with local legislation and standards. Atlas Copco
More informationERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)
ERAH MC Ka AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) Range 394-1220 kw Liquid chillers air condensing unit Package external installation Screw compressors
More informationClosed Circuit Coolers Technology for the Future, Available Today
Bulletin 204-E Metric Closed Circuit Coolers Advanced Technology for the Future, Available Today Mr. GoodTower Exclusive Thermal-Pak Coil Z-725 Galvanized Steel Construction Totally Enclosed Fan and Pump
More informationFibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.
1 3 2 4 5 Closed Circuit Cooling Tower Factory Assembled - Modular Compact Design 1 IP56 Motor(s) directly coupled to low energy and high efficient fan(s) 2 Fibreglass reinforced polyester (FRP) sandwich
More informationprecision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs
next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled
More informationBaltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT
CLOSED CIRCUIT COOLING TOWERS COUNTERFLOW INDUCED DRAFT GENERAL DESCRIPTION: Commercial applications demand reliable, cost effective and energy efficient solutions. With an ever increasing focus on operational
More informationAir Conditioning Components
Air Conditioning Components Agenda AC Components Compressor & Clutch Condenser Receiver-drier or Accumulator Expansion Valve or Orifice Tube Evaporator Compressor 2 primary purposes Increase pressure &
More informationICEU 36 SPARE PARTS LIST REV. 07/2016
ICEU 36 ~ SPARE PARTS LIST REV. 07/2016 ICEU 36 1 UNIT PANELS UP TO S.N. 02594 2 UNIT PANELS FROM S.N. 02595 3 REFRIGERANT SYSTEM AIR COOLED UP TO S.N. 02413 4 REFRIGERANT SYSTEM AIR COOLED - FROM S.N.
More informationProducts catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES
Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES 1 2 3 Heat Merchants have partnered with Energy Panel to offer the most advance technology in Thermodynamic Solar Systems for both residential
More informationAIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.
AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG. Page1 CONTENT: 1. Product Description 2. Product Specifications 3. Operating Procedure 4. Observation Table 5. Calculations 6. Result Page2
More informationPool dehumidification. Airpool+
Pool dehumidification Airpool+ Airpool + The new high performance Airpool+ dehumidifier is used for the dehumidification of indoor pools. Thanks to its design, in which the cooling circuit s components
More informationSPLIT SYSTEM HEAT PUMPS 14 SEER
(498) SPLIT SYSTEM HEAT PUMPS 14 SEER Models E*RE0 thru E*RE048 Nominal Capacity: thru 48 MBH DESCRIPTION The ERE series heat pumps are designed for use with a variety of UPG evaporator sections to suit
More informationTEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY
EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY AUTOMATIC ROTARY AIR FILTERS Self-cleaned rotary air filter can be used in various applications. General area of use is textile plants for filtering
More informationSlim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump
0-0V ~ 0Hz Ph 0-0V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Ducted Split System Heat Pump - - - 0 - - - 0 DC Inverter Inverter Technology $ Operation Hydrophilic Aluminum Fins Independent
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
More informationPGDX Rectangular duct coolers with DX coil
PGDX Rectangular duct coolers with DX coil Rectangular duct coolers with DX Coil PGDX Rectangular duct coolers with DX coil The PGDX is used for central cooling of the ventilation air in a ventilation
More informationPressure Enthalpy Charts
Pressure Enthalpy Charts What is a p-h Diagram? A p-h diagram is a diagram with a vertical axis of absolute pressure and a horizontal axis of specific enthalpy. "Enthalpy is the amount of energy in a substance
More informationHigh Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value
High Inlet Temperature Air Dryer Membrane Air Dryer After-Clooler Oil-Water Separator Automatic Value 1 2 3 4 5 6 7 8 9 1 HYD model Control Panel 1. on HYD-150 and smaller - It is equipped with a low pressure
More informationAQUASNAP JUNIOR 30RHV
High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11
More informationEvaporative Condensers
VXC - E 13 Evaporative Condensers Product Detail VXC Evaporative Condensers... E14 Benefits... E16 Construction Details... E18 Custom Features and Options... E20 Accessories... E22 Engineering Data...
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationCB18/CBS18 Bulletin # September 1994 Supersedes August 1986
ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED
More informationEKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata
EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata
More informationHeat Pump Water Heater Commercial Leaflet 2012
Heat Pump Water Heater Commercial Leaflet 2012 1 Table of contents............... 2 Bosch Group Innovation as a principal Established in 1886 in Stuttgart, Germany, Robert Bosch Corporation has been characterised
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More informationCATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42
SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING
More informationPrecise Temperature Control; Compact Footprint
Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp
More informationProduct Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C
Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and
More informationLOW STATIC HYDRONIC DUCTED UNIT
LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity
More informationHeat Recovery Ventilators (HRVs) Flexibility. in Perfect Form. Improving indoor air quality through better ventilation
Flex 100H Heat Recovery Ventilators (HRVs) Flexibility in Perfect Form Improving indoor air quality through better ventilation An Established Ventilation Solutions Provider Fantech For over two decades,
More informationGas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities
Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Capacities W E A R E F R I E N D L Y T O T H E E A R T H Gas Fired DOUBLE-EFFECT Chiller-Heater Absorption Principle Yazaki MG-Series
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationCO2 TRANSCRITICAL BOOSTER SYSTEMS
CO2 TRANSCRITICAL BOOSTER SYSTEMS William Katz Sr. Technical Writer Hillphoenix 2016 Gees Mill Road Conyers, GA 30013 Tel: 678-613-9364 Email: william.katz@hillphoenix.com Refrigeration systems for supermarkets
More informationOptiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.
Optiline Fan Array The optimum number of fans for every application The Optimum in Sound Energy Size Redundancy Reliability Energy Labs was before was cool Introduction Energy Labs was the first manufacturer
More informationEvaporators. Direct Expansion Flooded Recirculated Over Feed
Evaporators Purpose: Liquid Refrigerant is Boiled from a Low Pressure Liquid to a Low Pressure Gas by Absorbing Heat from the Medium that is being Cooled Types: Direct Expansion Flooded Recirculated Over
More informationHRV-IP. Ceiling Type Heat Pump Heat Recovery Unit
HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger
More informationCrate washer EKW-1500
Crate washer EKW-1500 Overview Suitable for crates with maximum dimensions of 600 x 400 mm (based on E-crates). The capacity of this unit is a maximum of 170 crates per hour with a staying time of 45 seconds.
More informationAir Conditioning Inspections for Buildings Condensers
. Air Conditioning Inspections for Buildings Condensers PRESENTED BY NIRAJ MISTRY aircon@stroma.com Condensers Condensing Process Three main types: Air Cooled (using ambient air) Water Cooled (using mains,
More informationHOLDING/PROOFING CABINETS HP2H-2M-SN APPLICATION OPTIONAL MODULAR CONSTRUCTION
HP1H-M-SN HP1V-M-SN HPH-M-SN HPV-M-SN HOLDING/PROOFING CABINETS APPLICATION To satisfy a need for high quality, shipboard grade, heated products, Cospolich has introduced their "HP" class of horizontal
More informationc Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2013) 2 / 25 T270 COP R = Q L
Refrigeration Cycles Dr. Md. Zahurul Haq Professor Department of Mechanical Engineering Bangladesh University of Engineering & Technology (BUET) Dhaka-1000, Bangladesh zahurul@me.buet.ac.bd http://teacher.buet.ac.bd/zahurul/
More informationRAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS
AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.
More informationHeadliner Systems. Headliner Systems KA-400 SLIMLINE...49 KK-400 SLIMLINE...51 KA-500 HARDHAT...53 KA KA KELVIN A/C...
Systems KA-400 SLIMLINE...49 KK-400 SLIMLINE...51 KA-500 HARDHAT...53 Systems KA-7100...55 KA-7300...57 KELVIN A/C...59 KELVIN HVAC...61 PASCAL A/C...63 47 NAME KA-400 SLIMLINE VOLTS 12 24 DESCRIPTION
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationTMCI Padovan Evaporators
TMCI Padovan Evaporators Evaporators Our range includes 4 types of evaporators: Forced Circulation Falling Film Evaporators Plates Thin Film Concentration systems Evaporator choosing criteria: product
More informationRefrigeration Cycles. Refrigerators, Air-conditioners & Heat Pumps. Refrigeration Capacity/Performance. Dr. Md. Zahurul Haq
Refrigeration Cycles Dr. Md. Zahurul Haq Professor Department of Mechanical Engineering Bangladesh University of Engineering & Technology (BUET) Dhaka-1000, Bangladesh zahurul@me.buet.ac.bd http://teacher.buet.ac.bd/zahurul/
More informationMarine Heat Exchangers SALES SERVICE REPAIR
Marine Heat Exchangers SALES SERVICE REPAIR Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PRODUC 104-32 Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL
More informationMODULAR CHILLER. R410a R22
Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model
More informationHeat Transfer Equipment
Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PR ODUC Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL APPLICATIONS SX2000 Pre-engineered fixed tubesheet
More informationTHE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.
THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. Central Chillers & Pump Tanks C E N T R A L C H I L L E R S 30RAP Series Central Chillers 10-60 Tons 30RAP Series air-cooled central
More informationGP SERIES Packaged Chillers
Material Handling Process Cooling Temperature Control Size Reduction Temperature Control Process Cooling Material Handling Size Reduction GP SERIES Packaged Chillers Precision Comprehensive Engineered
More informationT270 COP R = Q L. c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2017) 2 / 23 T354
Refrigerators, Air-conditioners & Heat Pumps Refrigeration Cycles Dr. Md. Zahurul Haq Professor Department of Mechanical Engineering Bangladesh University of Engineering & Technology (BUET) Dhaka-1000,
More informationReliable products with long-term, low cost of ownership
Evaporative Condensers Reliable products with long-term, low cost of ownership For Industrial Refrigeration EVAPORATIVE CONDENSERS Why buy FRICK products? FRICK History includes a great reputation for
More informationVOLUME 2 (BOQ & Price Bid)
TENDER DOCUMENT NIT No: PAT/CON/721/01 FOR Tender for Supply, Erection & Commissioning of Refrigeration Plant for chilled water system for Ice-Cream mix section complete for 20 KLPD Ice Cream Plant at
More informationHigh temperature air-to-water heat pumps
Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors