1 SNOWCOOL SYSTEMS INDIA PVT LTD. PRESENTS LARGEST RANGE OF AIR-COOLED FAN FLUID COOLERS CAPACITIES FLUID FLOW 2 CMH TO CMH HOT FLUID 35 C TO 195 C CONSTRUCTION VERTICAL OR FLAT BED MONO OR MULTI CELLS MODULAR OR SITE-ERECTED TYPE INDUCED OR FORCED DRAFT DRY, ADIABATIC OR HYBRID OPERATION
2 What is Air-Cooled Fan Fluid Cooler? Why Fluid Cooling is required? A Heat Exchanger is specialized Equipment in which Two Fluids (Hot and Cold) are brought into indirect contact with each other to affect the Transfer of Heat. Fan Fluid Cooler is a Air-Cooled Heat Exchanger that operate on the principle of removing Heat of Fluid flowing in closed-loop Coil and by drawing Fresh Ambient Air over Coil Surface, thus Cooling the Hot Fluid. Since Ambient Air Movement is via Axial Propeller Fan and Cooling Mode is totally Dry, these types of Equipments are popularly known as Fan Fluid Coolers or Fin Fan Coolers or even Dry Cooling Towers. The major Advantages of Fan Fluid Coolers over conventional Evaporative Cooling Towers are No-loss of Cooling Fluid being Closed-loop; vide variety of Fluids including Water, better Control of Cooling, Power & Water Saving, and importantly Maintenance-free Performance being Dry Operation. The biggest Dis-advantage of Fan Fluid Cooler remains that Fluid Temp can t be bring down below Ambient Air Temp in Dry Mode, unlike in Evaporative Cooling Tower which delivers Water Temp below Ambient Air Temp (nearby its Wet-Bulb Temp). When Fluid Outlet Temp is required below Ambient Air Temp, Adiabatic Fan Fluid Coolers are proposed, wherein incoming Ambient Air is cooled by Adiabatic Mode of Air-Cooling (via Water Spraying or Fogging). When Adiabatically Cooled Ambient Air cools the Fluid, the Fluid Temp comes down with approach to Wet-Bulb Temp of Ambient Air. Hybrid Fan Fluid Coolers or Hybrid Cooling Towers is a Fluid Cooler which uses Dry as well as Adiabatic Mode for Fluid Cooling, thus delivering Constant Temp Cooled Fluid and ensuring optimized consumption of Fan Power and Spray Water. Hybrid Fan Fluid Coolers is considered to be replacement of Evaporative Cooling Towers and bears all Advantages of Dry Coolers.
3 Fluid (including Water) Cooling is needed for AC & R Plants, Inter-coolers and After-coolers, Engine Jackets, Smelters and Furnaces, Acid Vessels, Production Processes involving Thermic Fluids, Oil Cooling, Condenser Cooling in Power Plants and many more. When Fluid is some Gas or Vapor and is to be condensed (phase change of Fluid), these Fan Coolers are termed as Air-cooled Condensers: and are commonly seen in AC & R Equipments. In Ammonia based Refrigeration Plants, Aircooled Condensers are supplemented with Evaporative Cooling by Water Spraying hence those are termed as Ammonia Evaporative Condensers. In Power Plants when Steam is to be condensed (as Water) by Air-cooled Coolers, those are termed as Air-cooled Steam Condensers. Based on Construction, Shape and Air Draft Mechanism, Fan Fluid Coolers are catagorised into Forced Draft (for High Temp Fluids, also termed as Air Blast Cooler) and Induced Draft (for Low Temp Fluids and Adiabatic Mode). Further, classification is as Vertical or Flat-Bed, Finned Coils or Finned Tubes and Modular or Site-Erected. At Snowcool we are prominent and established player in all types of Fan Fluid Coolers, viz. Fan Fluid Coolers, Fin Fan Coolers, Air Blast Coolers, Vertical Fin Fan Coolers, Flat Bed Fin Fan Coolers, Adiabatic Fan Fluid Coolers, Hybrid Fan Fluid Coolers, Air-Cooled Thermic Fluid Coolers, Air-Cooled Oil Coolers, Dry Cooling Towers, Evaporative Condensers, Air-cooled Condensers, Air-cooled Steam Condensers and many more..
4 How Fan Fluid Cooler works? How to select Fan Fluid Cooler? FACTORS TO BE CONSIDERED FOR SELECTING FAN FLUID COOLERS : APPLICATION (CONDENSOR COOLING / UTILITY / ENGINE / PROCESS) FLUID FLOW (CMH / LPH / GPM / KGPH) HOT FLUID INLET ( C / F) COLD FLUID OUTLET ( C / F) ATMOSPHERIC AIR CONDITIONS, DRY BULB TEMP ( C / F) & RH (%) FLUID TYPE (INDUSTRIAL WATER / DM WATER / OIL / THERMIC FLUID) WATER AVAILABILTY (FOR ADIABATIC OR HYBRID MODE) POWER AVAILABILITY (MECHANICAL DRAUGHT / WATER PUMPING) SPACE AVAILABILITY (AREA / INSTALLATION LOCATION) COST BUDGETS (CAPITAL COST / MAINTENANCE COST / LIFE) SERVICEABILITY (REPAIRS / REPLACEMENT / SKILLS) EFFICIENCY (WATER & POWER CONSUMPTION / FLUID PR DROP)
5 SNOWCOOL LARGEST RANGE OF AIR-COOLED FAN FLUID COOLERS TYPE COOLING APPLICATION MIN - MAX FLUID OUTLET TEMP (⁰C) VERTICAL FIN FAN COOLER CONDENSOR WATER VERTICAL FAN FLUID COOLER PROCESS FLUID / WATER FLAT BED FIN FAN COOLER PROCESS FLUID / WATER FLAT BED FAN FLUID COOLER PROCESS FLUID / UTILITY WATER AIR BLAST FLUID COOLER THERMIC FLUID / OIL VERTICAL ADIABATIC FIN FAN COOLER CONDENSOR / UTILITY WATER FLAT BED ADIABATIC FAN FLUID COOLER CONDENSOR / UTILITY WATER FLAT BED HYBRID FAN FLUID COOLER CONDENSOR / UTILITY WATER 28-35
6 FLUID FAN COOLERS - TYPES & APPLICATIONS VERTICAL V-STYLE FIN FAN FLUID COOLER FOR STANDARD, CLEAN ATMOSPHERE DRY MODE OF OPERATION FLAT BED FIN FAN FLUID COOLER FOR STANDARD, CLEAN ATMOSPHERE DRY MODE OF OPERATION VERTICAL V-STYLE FIN FAN FLUID COOLER FOR STANDARD, CLEAN ATMOSPHERE DRY & ADIABATIC MODE OF OPERATION FLAT BED FLUID FAN COOLER FOR INDUSTRIAL, CORROSIVE & DUSTY ATMOSPHERE DRY & ADIABATIC MODE OF APPLICATION
7 FLUID FAN COOLERS - COIL CONSTRUCTION ALUMINIUM FINNED COPPER TUBE COIL FOR STANDARD, CLEAN ATMOSPHERE DRY MODE OF APPLICATION SS FINNED SS TUBE COIL FOR COASTAL & CORROSIVE ATMOSPHERE DRY & ADIABATIC MODE OF APPLICATION SS PLAIN TUBE COIL FOR INDUSTRIAL, CORROSIVE & DUSTY ATMOSPHERE ADIABATIC MODE OF APPLICATION INTEGRALLY FINNED SS TUBE COIL FOR INDUSTRIAL, COASTAL & CORROSIVE ATMOSPHERE DRY & ADIABATIC MODE OF APPLICATION
8 FLUID FAN COOLERS FANS COMPACT AXIAL FANS INDUCED DRAFT, FIXED ALUMINIUM BLADES MULTIPLE FANS PER CELL PROPELLER TYPE AXIAL FAN INDUCED DRAFT, ADJUSTABLE ANGLE FRP BLADES DIRECT DRIVEN, SINGLE FAN PER CELL PROPELLER TYPE AXIAL FAN FORCED DRAFT, ADJUSTABLE ANGLE AL-ALLOY BLADES DIRECT DRIVEN, TWO FAN PER CELL AEROFOIL TYPE AXIAL FAN INDUCED DRAFT, ADJUSTABLE ANGLE FRP BLADES DIRECT DRIVEN, ONE FAN PER CELL
9 FLUID FAN COOLERS ACCESSORIES ADIABATIC SPRAY SYSTEM SOLENOID CONTROLLED MULTIPLE SPRAY CIRCUITS SPRAY CONTROL IN RESPONSE TO AMBIENT AIR TEMP WATER SPRAY BOOSTING PUMPS VERIABLE SPEED PUMPING, CONSTANT PRESSURE DEDICATED CONTROLLER, SKID MOUNTED MODULE INTELLEGENT MCC PANELS CENTRILISED MONITORING, BMS & DCS COMPATIBILITY HIGHEST ON SAFETY & RELIABILITY FAN VARIABLE SPEED CONTROLLERS COOLER MOUNTED, RAIN-DUST PROOF PANELS PRESSURE BOOSTING FOR ADIABATIC SPRAYS
10 FLUID FAN COOLERS INTEGRATED PROJECT SOLUTIONS FLUID COOLING INTEGRATED PROJECT COMPRISING OF ADIABATIC FAN FLUID COOLERS, SPRAY BOOSTER PUMPS, INTELLIGENT MCC PANEL, DCS CONNECTIVITY, ELECTRICAL SYSTEM AND MANY MORE ONE STOP PROJECT SOLUTION
11 - NOTES - sales@snowcoolsystems.com
12 Thank you Visit our Website to know more about us Write us for Customised Solution sales@snowcoolsystems.com SNOWCOOL SYSTEMS INDIA (P) LTD. Marketing Head Office 20, Asiatic Arcade, Pokhran Road No 1, Vartak Nagar, Thane (W) , (Mumbai) India Tel / Fax : , Sales Offices / Representatives in All Major Cities across India, please Visit our Website for Contact Details
SNOWCOOL SYSTEMS INDIA PVT LTD.
SNOWCOOL SYSTEMS INDIA PVT LTD. PRESENTS LARGEST RANGE OF COOLING TOWERS CAPACITIES WATER FLOW 10 CMH TO 100000 CMH HOT WATER 35 C TO 85 C CONSTRUCTION FRP & RCC SINGLE & MULTIPLE CELLS CUBICAL & HYPERBOLIC
More informationWe are engaged in manufacturing, exporting, trading and supplying of Cooling Equipment such as Air Cooled Chillers, Water Cooled Chillers,
+91-8048718646 Snowcool Systems India Private Limited http://www.chillers-coolers.com/ We are engaged in manufacturing, exporting, trading and supplying of Cooling Equipment such as Air Cooled, Water Cooled,
More informationClosed Circuit Cooling Towers
Closed Circuit Cooling Towers Overview Closed circuit cooling towers provide evaporative cooling for many types of systems, and the specific application will largely determine which BAC Closed Circuit
More informationARCTIC EVAPORATIVE COOLING. Direct Evaporative Coolers Indirect Evaporative Coolers Dew Point Evaporative Coolers
ARCTIC EVAPORATIVE COOLING ECONOMICAL SCALABLE SUSTAINABLE Direct Indirect Dew Point UL TRA MODULE ULTRA MODULE Comprehensive Evaporative Cooling Solutions At the Pahwa Group, continuous Innovation is
More informationVOLUME 2 (BOQ & Price Bid)
TENDER DOCUMENT NIT No: PAT/CON/721/01 FOR Tender for Supply, Erection & Commissioning of Refrigeration Plant for chilled water system for Ice-Cream mix section complete for 20 KLPD Ice Cream Plant at
More information+91-8071681962 Pioneer Engineering Works http://www.heatexchangerpioneer.com/ We are engaged in Industry of Manufacturing & Supplying of heat exchangers, oil coolers, heat exchangers in Coimbatore, oil
More informationAir Conditioning Inspections for Buildings Condensers
. Air Conditioning Inspections for Buildings Condensers PRESENTED BY NIRAJ MISTRY aircon@stroma.com Condensers Condensing Process Three main types: Air Cooled (using ambient air) Water Cooled (using mains,
More informationPresenters. Brett Alexander. Mihir Kalyani. Troy Reineck
ow Brett Alexander Presenters Mihir Kalyani Troy Reineck Designing Your Water Treatment Program for Different Types of Heat Rejection Equipment Types of Heat Rejection Equipment Open Cooling Tower Closed
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
More informationWhat is a Closed circuit Cooling Tower (CCT)?
What is a Closed circuit Cooling Tower (CCT)? Closed circuit Cooling Towers are hybrids that pass the working fluids through a tube bundle, upon which clean water is sprayer and a faninduced draft applied.
More informationProducts and Services
Products and Services Evaporative Cooling HVAC Refrigeration Light to heavy industrial Chemical processing, refining Power generation MARLEY NC EVEREST CROSSFLOW COOLING TOWER NC Everest s preassembled
More informationEnergy Efficiency Considerations in Refrigeration Systems
Energy Efficiency Considerations in Refrigeration Systems Donall O Brien Industrial Energy Consultant Why Focus on Refrigeration? Refrigeration & Cooling is responsible for approx. 20% of all Electricity
More informationMechanical Systems Mechanical Systems
VING IMPRO ALLY NATUR Mechanical Systems 2017 Mechanical Systems E RMANC PERFO Content Rack Units Racks Units Opti OL Indoor Mini Compact OLtec EVO Maxi Compact Flexi Optivell Innovell Econvell Maxivell
More informationEvaporative Condenser. Energy Saving Evaporative Condenser
EVAP-PAK Evaporative Condenser Energy Saving Evaporative Condenser Temp Tech is the Leader in Industrial Refrigeration Plate Evaporative Condenser Reduces Energy Consumption The Heat Transfer Technology
More informationMH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.
MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE. Hybrid Design. Utilizing a combination of evaporative fill media and prime surface coil(s), the MH Fluid Cooler offers significantly improved performance
More informationMH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE.
MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE. Hybrid Design. Utilizing a combination of evaporative fill media and prime surface coil(s), the MH Fluid Cooler offers significantly improved performance
More informationDesign Based Comparative Study of Several Condensers Komal B. Dabhi 1, Prof. S. B. Thakore 2 1 Chemical Engg. Dept., L. D. College of Engineering, Ahmedabad 380015 2 Chemical Engg. Dept., L. D. College
More informationImplementation of Energy Saving measures in Existing Buildings
Building Surveyors Conference on Building a Green and Sustainable Future Implementation of Energy Saving measures in Existing Buildings 5 September 2009 Energy Efficient / Environmental Friendly Products
More informationThe Industrial water cooling specialists WWW.TOTALPROCESSCOOLING.CO.UK CHILLERS TPC Chillers (Air Cooled Industrial Process Chillers, Oil Chillers and Packaged Chillers) with capacities from 1kW upwards
More informationGüntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility
Güntner Info GVX with microox technology 6 525 kw Always a step ahead: microox condenser system with maximum installation flexibility The new standard for flexibility, technology Energy-saving operation
More informationCO2 TRANSCRITICAL BOOSTER SYSTEMS
CO2 TRANSCRITICAL BOOSTER SYSTEMS William Katz Sr. Technical Writer Hillphoenix 2016 Gees Mill Road Conyers, GA 30013 Tel: 678-613-9364 Email: william.katz@hillphoenix.com Refrigeration systems for supermarkets
More informationBe sustainable while protecting your business
Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair
More informationCABERO PRODUCT CATALOGUE
CABERO PRODUCT CATALOGUE AIR COOLED CONDENSERS WITH AXIAL FANS ACH / ACV (MONO COIL) air conditioning and refrigeration systems 5-1,420 kw REFRIGERANTS: available for all refrigerants incl. NH 3 and CO
More informationTOPAZ ADIABATIC COOLER
TOPAZ ADIABATIC COOLER CONTENT Page Principle and operation 2 General description and benefits 3 TECHNICAL DOCUMENTATION Manufacturing details Options 4 6 Drawings and dimensions 7 On site lay out 8 Technical
More informationAppendix 13. Categories of Cooling and Heating systems
EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01
More informationRefrigeration Plant Information. We Speak Hockey 365
Refrigeration Plant Information We Speak Hockey 365 Introduction For 100 years, it s been accepted that ice rinks come with a multitude of expensive and reoccurring problems; not to mention astoundingly
More informationMECHANICAL SERVICES 101. Ian White
MECHANICAL SERVICES 101 Ian White Contents 1. Ventilation 2. Heat Gains & Losses 3. Heating Ventilation Air Conditioning (HVAC) Systems What are Building Services Building Services incorporate all aspects
More informationUEE11 Electrotechnology. Training Package. UEENEEJ107A Air conditioning and refrigeration systems, major components and associated equipment SAMPLE
UEE Electrotechnology Training ackage UEEEEJ07A Air conditioning and refrigeration systems, major components and associated Learner Workbook Version Training and Education Support Industry Skills Unit
More informationOPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling
MORE n More efficient n More flexible n More intelligent for LESS n Less energy n Less time n Less noise Capacity: up to 1100 kw 410A 407C 134a 404A Free cooling Water misting Use The range, available
More informationHEATING & COOLING COIL PRODUCTS
HEATING & COOLING COIL PRODUCTS FV & FVH FLOOR MOUNTED COOLERS Capacities 28-150kW White powder coated casing Aerofoil fans 4, 6 or 8mm fin spacing Vertical or horizontal air discharge HEATING & COOLING
More informationINFO. Compact V-SHAPE. Condenser GCDC for HFCs and propane Gas cooler GGDC for CO 2 Fluid cooler GFDC for water/glycol and other fluids.
INFO V-SHAPE Compact Condenser GCDC for HFCs and propane Gas cooler GGDC for CO 2 Fluid cooler GFDC for water/glycol and other fluids 13 560 kw In a class of its own Our new V-SHAPE Compact series now
More informationTechnically Driven Heat Exchangers
JC Equipments Pvt. Ltd Technically Driven Heat Exchangers Profile JC is the leading ISO-9001-2008 certified, ASME U & S Stamp Authorized Designer, Manufacturer and Exporter of Industrial Cooling Towers
More informationOperating Performance
INFORMATION SHEET 1 Jackson Engineering Advisers are specialist Building Services Engineers. This information sheet is offered as an aid to Building Owners and Managers as a guide to plant life expectancies.
More informationAdsorption Chillers Energysmart Green Cooling
Adsorption Chillers Energysmart Green Cooling New Partners in innovation Leaders in Dehumidification... Worldwide Power Partner Inc USA www.bryair.com Recover Low Grade Process Waste Heat For Energy Smart
More informationVicot Air Conditioning Co., Ltd. CONTENT
CONTENT I. Introduction 2 II. Absorption Principle 3 III. GAX Absorption Cycle 3 IV. Major Component Description and Function 4 V. Features 4 VI. Performance curve 5 VII. Nomenclature 5 VIII. Technical
More informationI T A L I A N T E C H N O L O G Y C O N S T R U C T I O N ENGLISH
I T A L I A N T E C H N O L O G Y C O N S T R U C T I O N ENGLISH PEOPLE AND ENVIRONMENT AT FIRST PLACE The business started in partnership back in 1978, but the turning-point came in 2002 with the adoption
More informationCTI Sponsored Educational Program
Presented By: Kent Martens SPX Cooling Technologies, Inc. Slide No.: 1 CTI Mission Statement To advocate and promote the use of environmentally responsible Evaporative Heat Transfer Systems (EHTS) for
More informationPAD. Adiabatic cooler. PAD series
Adiabatic cooler MITA Adiabatic cooler General information Adiabatic cooling is a thermodynamic phenomenon by which air temperature is decreased through humidification. The temperature than can be reached
More informationLeadership, Innovation, Advanced Technology Synergise Here!
Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified
More informationAIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw
COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation
More informationData Centre Cooling Solutions
Data Centre Cooling Solutions DIGITAL REVOLUTION In 2016 we produced as much data as in the entire history of humankind through 2015. POWER NEEDS It is estimated that 1,5% of globally generated power is
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationPrivately held company
WELCOME Founded in 1948 by our late Chairman, Mr Mahendra Swarup Privately held company Designing and manufacturing evaporative water cooling towers and other products related to process cooling for over
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More information2. CURRICULUM. Sl. No.
. CURRICULUM Sl. No. Code Title No. of Lecture Hours 1 RAC 001 Fundamentals of Refrigeration and Air 60 conditioning RAC 00 Psychrometry, Heat load Estimation for 70 Air conditioning and Refrigeration
More informationData Centre Cooling Solutions
Data Centre Cooling Solutions Heat Exchange Solutions ThermoKey DIGITAL REVOLUTION In 2016 we produced as much data as in the entire history of humankind through 2015. POWER NEEDS It is estimated that
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationWhat is Cooling S.Sen
What is Cooling Tower @ S.Sen Gear Box Stack Shaft Fan Blade Motor Fill Theory of Cooling Towers Cooling towers fall into two main sub-divisions: natural draft and mechanical draft. Natural draft designs
More informationORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS
ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating
More informationDbm Coils S.p.a. is the largest privately owned coil manufacturer in Europe. The factories take up a total surface of 70,000m 2.
THE COMPANY: 4d Air Products Limited are the UK Sales Agent for Dbm Coils S.p.a. As experts in Thermal Transfer Technology, 4d Air Products Limited supplies coils to the Air Handling, Refrigeration, Process,
More informationRefrigeration System Overview. ASTI 32 Hour Managing Ammonia Course September 27 30, 2016
Refrigeration System Overview ASTI 32 Hour Managing Ammonia Course September 27 30, 2016 A refrigeration system is a mechanical heat transport system. The system absorbs heat energy from an area it is
More informationDEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM
DEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM Zhang Yue, CEO Broad Air Conditioning, Ltd., Changsha, China Ronald Fiskum, Integrated Energy Systems Project
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationPerformance Optimization of the Evaporative Condenser Design
Performance Optimization of the Evaporative Condenser Design Mit. C. Patel P.G.Student, Mech. Engg.Dept. Institute of Technology, Nirma University, Ahmadabad, Prof. B. A. Shah Mechanical Engineering Department
More informationPRODUCT GUIDE SPECIFICATIONS
Project Name: Customer PO #: Model Number: Factory: Greenup Serial No: Representative: Product Guide Specification 1. SUMMARY 1.1. This specification describes the requirements for the Evapcold Packaged
More informationThe ultimate in air handling units: directly and indirectly fired
KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationThe regenerative cooling system. Ka 2 O. Co-funded by the Eco-innovation Initiative of the European Union
The regenerative cooling system Ka 2 O Co-funded by the Eco-innovation Initiative of the European Union Ka 2 O-technology: Indirect evaporation cooling for air handling units. adiabatic efficiency: 96
More informationMethod to test HVAC equipment at part load conditions
IPLV Method to test HVAC equipment at part load conditions For water cooled chillers: 100% load ( % hrs) + 75% ( Hrs ) + 50% ( Hrs ) + 25% ( Hrs ) = IPLV value Manufacturer can favor this number by tweaking
More informationHeat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:
Heat Pumps SA SERIES SA Series Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum
More informationMECHANICAL VACUUM BOOSTERS:-
MECHANICAL VACUUM BOOSTERS:- Mechanical Vacuum Boosters are dry pumps that meet most of the ideal vacuum pump requirements. They work on positive displacement principle and are used to boost the performance
More informationMath. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.
HVAC Math The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. Math F. to C. Conversion = (f-32)*(5/9) C. to F. Conversion = C * 9/5 +
More informationEXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM
EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM AUTHOR 1.ME Student Mech Engg Dept,Godavari COE, Jalgaon,Maharashtra, India 2.Asso. Prof. & Head, Mech Engg Dept,Godavari COE, Jalgaon,Maharashtra,
More informationNeosys Product catalogue
00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled
More informationIntrCooll. Cool large buildings at 80% lower running costs
IntrCooll Cool large buildings at 80% lower running costs IntrCooll INDIRECT/DIRECT ADIABATIC COOLING COOLING CAPACITY UP TO 134 kw (38 TR) UP TO 116% WET-BULB EFFICIENCY EER UP TO 44 (150 BTU/Wh) Introduction
More informationAIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw
PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor
More informationChillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw
Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to 1.99 kw Centrifugal compressor with magnetic levitation This is a miniaturized, highly innovative
More informationCONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY
CONDENSING UNITS. AIR COOLED CONDENSER. CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY SERIES: DXCZ MODELS: 171, 201, 221, 251, 271, 351 371, 401, 451, 501, 701 and 721 COOLING CAPACITIES OF: 4,7
More informationCondensing Units CUS 15-60
Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....
More informationHeat sinks for electronic cooling applications
Heat sinks for electronic cooling applications Shubhash V. Jadhav Department of Mechanical Engineering, SVERI s College of Engineering Pandharpur, Introduction The previous century brought the miniaturization
More informationFigure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)
Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems) Figure 17-2 Commercial refrigeration Unit Figure 17-3 Industrial process chiller Figure 17-4 Basic refrigeration
More informationEvaporators 60HZ version
Innovative Engineering Catalogue Evaporators 60HZ version Heat Exchangers Application areas Freezer rooms Cold rooms Packaging rooms Processing rooms Humidity controled cold rooms Air conditioning Refrigerated
More informationAC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT
AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT Central Chiller Plant (with Cooling Tower and Chilled Water distribution) The other AC configuration is called a Chilled Water or Larger Cooler system. It
More informationWater Chiller Solutions. A solution to every water cooling need.
Water Chiller Solutions A solution to every water cooling need. During the harsh summers of Middle East, the ambient temperature is very high and it can go up to as much as 52 o C. Naturally, in such conditions,
More informationEvaporative Condensers
J2 BAC offers evaporative condensers in six different styles to suit every industry application. CXV Models - CXV models deliver efficient performance in an easy-to-maintain package. BAC s combined flow
More informationTEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY
EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY AUTOMATIC ROTARY AIR FILTERS Self-cleaned rotary air filter can be used in various applications. General area of use is textile plants for filtering
More informationHeat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:
Heat Pumps SA SERIES Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum and reduced maintenance Double wall rigid polyurethane foam injected panel
More informationHRV-IP. Ceiling Type Heat Pump Heat Recovery Unit
HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger
More informationAdvance Split
Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.
More informationLSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES
Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures
More informationSECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.
SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More informationKüba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing
High-performance air cooler for blast chilling and shock freezing engineering for a better world GEA Heat Exchangers High-performance air cooler for blast chilling and shock freezing Large fin spacing
More informationTechnical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:
Refrigeration Systems Theoretical hours: 2 Practical hours: 2 Units: 6 COOLING TOWERS First 10 minutes: review the last lecture. Then explain the new lecture, solve an example. Last 10 minutes review the
More informationMODULE 6 HUMIDIFICATION AND AIR CONDITIONING
MODULE 6 HUMIDIFICATION AND AIR CONDITIONING LECTURE NO. 3 6.3 Humidification and dehumidification operations and design calculations Humidification operations: In this operation, water transfers from
More informationDepartment of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202
Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202 Applied Thermodynamics Sessional Credit Hours: 0.75 General Guidelines:
More informationMLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers
MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons n Mission Critical Cooling n Central Plant Process Cooling n Specialized HVAC Cooling Systems COOLING SOLUTIONS
More informationInnovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)
Innovative Engineering Catalogue Evaporators EKL1. Extra low temperature applications (60 Hz) Heat Exchangers www.eka-kool.com Application areas Freezer rooms Cold rooms Packaging rooms Processing rooms
More informationCOLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd
COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd Abstract This paper presents the design approach adopted for the expansion of a large existing
More informationThe ultimate in air handling units: directly and indirectly fired
KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationAutomatic Drain Valves. Lasting Values. Series LDV
Lasting Values Automatic Drain Valves Series LDV Zero Air Loss Noise Free Condensate Sensing Type Design Patented India s Largest Exporter of Compressed Air Treatment Products The LDV Series Trident s
More informationIncreased Performance Higher System Efficiency Low Refrigerant Charge Compact Design
A Wholly Owned Subsidiary of EVAPCO ADVANCED MicroChannel T E C H N O L O G Y Increased Performance Higher System Efficiency Low Refrigerant Charge Compact Design MADE IN THE USA MicroChannel Heat Excha
More informationChapter 14, Problem 27.
Chapter 14, Problem 27. A house contains air at 25 C and 65 percent relative humidity. Will any moisture condense on the inner surfaces of the windows when the temperature of the window drops to 10 C?
More informationGandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]
Experiment 1 Study of fundamentals of Fluid Flow and Heat Transfer associated with Heat Exchangers Review questions (1) Significance of dimensionless numbers. (2) Define overall heat transfer coefficient.
More informationPerformance of window air conditioner using alternative refrigerants with different configurations of capillary tube
ISSN: 2347-3215 Volume 1 Number 4 (2013) pp. 46-54 www.ijcrar.com Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube Richa Soni 1*, P.K.Jhinge
More informationMidwest Industrial Initiative Webinar: Industrial Refrigeration
Midwest Industrial Initiative Webinar: Industrial Refrigeration Opportunities for Energy Efficiency and Cost Savings Thursday, June 6, 2013 www.kw-engineering.com Bryan Hackett, PE kw Engineering What
More informationCommercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark
Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark Introduction: Energy use is the single largest operating expense in commercial office
More informationBASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology
BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS...world leaders in heat transfer technology Everything you want in a heat exchanger and less API Heat Transfer Basco Type ES Extended Surface Plate
More informationGENERAL CAPABILITIES
GENERAL CAPABILITIES Reliable Process Heating Solutions HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA 15106 Phone 412-276-3388 Fax 412-276-3397 www.heat-inc.com FROM CONCEPT TO COMPLETION,
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More information