Installationsplan / Installation plan PW 6161 EL

Size: px
Start display at page:

Download "Installationsplan / Installation plan PW 6161 EL"

Transcription

1 Installationsplan / Installation plan Installatietekening Plan d`installation Pianta di installazione Plano de instalación Plano de instalação Σχέδιο εγκατάστασης Asennusohje Installasjonsplan Installationsplan G PW 6161 EL Materialnummer / Mat. no.: Änderungsstand / Version: 00 Datum Zeichnung / Drawing date: Datum Legende / Legend date:

2

3

4

5

6

7 Technical datasheet Washer-extractor: Heating: PW 6161 Electric (EL) Legend: Circled, bold-type abbreviations: Connection required Abbreviations surrounded by broken circle: Connection optional or required, depending on model G Optional extras: UM Miele plinth UG/UO 6016 (UG = Box plinth/uo = Open plinth) Height Model mm 237 Width UG (UO) mm 920 (900) Depth UG (UO) mm 939 (899) BS Concrete platform Concrete platform optional (Min. quality B15) Recommended height mm 237 Minimum height mm 100 Recommended width mm 920 Recommended depth mm 910 Ensure good anchorage! Machine connections: Electrical 1. Standard voltage (as supplied) V 3N AC connection Frequency Hz Rated load kw 17 Fuse rating A 3 25 Supply lead, min. cross section mm² Standard voltage (as supplied) V 3 AC Frequency Hz Rated load kw 17 Fuse rating A 3 50 Supply lead, min. cross section (M 32) mm² Standard voltage (as supplied) V 3 AC 440 Frequency Hz 60 Rated load kw 17 Fuse rating A 3 25 Supply lead, min. cross section mm² Plug and socket connection recommended to facilitate electrical safety tests. Socket must be accessible after installation. In the case of hard-wired connections, an all-pole mains switch with a minimum contact gap of 3 mm must be provided. The use of an earth leakage circuit breaker (ELCB) is strongly recommended. If necessary, equipotential bonding with good galvanic contact must be provided in accordance with all appropriate national and local regulations. Peak load management Connection cable, min. cross-section mm² Input leads should not be in direct contact with any source of heat. Input signal via potential-free (galvanically separated) contact. Installationsplan PW 6161 EL Stand: Seite 7

8 Cold water (Soft water) Min. flow pressure kpa 100 Max. pressure kpa 1000 Max. throughput (if hot water supply is not available) l/min 26 (36) On-site connection thread according to DIN Inch ¾" external thread Length of connection hose (supplied) mm 1500 Water requirements (average for 60 C programme) Standard connection [with hot water connection] l/h not yet available Additional requirements if hot water supply is not available. Hot water Max. temperature C 70 Min. flow pressure kpa 100 Max. pressure kpa 1000 Max. throughput l/min 10 On-site connection thread according to DIN Inch ¾" external thread Length of connection hose (supplied) mm 1500 Water requirements (average for 60 C programme) Standard connection [with hot water connection] l/h not yet available If no hot water supply, connect hose to cold water! Raw water Min. flow pressure kpa 100 Max. pressure kpa 1000 (Optional) Max. throughput l/min 32 On-site connection thread according to DIN Inch ¾" external thread Length of connection hose (supplied) mm 1500 Water requirements (average for 60 C programme) Standard connection [with hot water connection] l/h not yet available If connected to raw water supply, subtract cold water (soft) volume. If no raw water supply, connect hose to cold water! Drainage via dump valve Max. temperature C 95 Machine drain connection (d a s l) [DN 70] mm On-site drain connection (d i s l) [DN 70 sleeve] mm Max. transient throughput l/min 200 Vented drainage required. If ventilation is insufficient, fit Miele kit, Mat. no Drain manifolds serving several machines must be of sufficient cross-section. Foam vent (Optional) Machine vent A drainage system for foam escaping from the drain vent can be built using standard drain pipe sections. An 87 branch with an end cap should be provided for this purpose. Vent machine interior to prevent excessive rise in pressure. Fittings (supplied) Miele plinth UG/UO metal angled brackets (to secure machine to plinth) 4 screws DIN 571 (Ø length) mm rawl plugs (Ø length) mm Machine must be secured! Fixing materials for floating screed floor to be provided on site On concrete platform 2 screws DIN 571 (Ø length) mm rawl plugs (Ø length) mm Machine must be secured! Fixing materials for floating screed floor to be provided on site Installationsplan PW 6161 EL Stand: Seite 8

9 Without plinth 2 screws DIN 571 (Ø length) mm rawl plugs (Ø length) mm Machine must be secured! Fixing materials for floating screed floor to be provided on site Machine data Width mm 920 Depth mm 910 Height mm 1400 Knocked-down dimensions (W H) mm 1000 x 1500 Recommended gap to opposite wall mm 1500 Net weight kg 458 Dynamic floor load, max. N 5469 Static floor load, max. N 5003 Drum frequency, max. Hz 19.2 Average heat dissipation (dependent on ambient room temperature and programme selected) W not yet available Installation should only be carried out by authorised fitters in accordance with valid regulations! Observe installation instructions when installing machine! All rights reserved! Installationsplan PW 6161 EL Stand: Seite 9

Installationsplan / Installation plan PG 8056

Installationsplan / Installation plan PG 8056 Installationsplan / Installation plan Installatietekening Plano de instalación Asennusohje Plan d`installation Plano de instalação Installasjonsplan Pianta di installazione Σχέδιο εγκατάστασης Installationsplan

More information

Installationsplan / Installation plan PG 8059

Installationsplan / Installation plan PG 8059 Installationsplan / Installation plan Installatietekening Plano de instalación Asennusohje Plan d`installation Plano de instalação Installasjonsplan Pianta di installazione Σχέδιο εγκατάστασης Installationsplan

More information

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 04

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 04 Installation recommendations Washer-extractor PW 6080 EL AV/LP 36.15 en - GB Mat. no. 07 580 680 / 04 United Kingdom Miele Co. Ltd. Fairacres, Marcham Road Abingdon, Oxon, OX14 1TW Professional Sales,

More information

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan Installation plan Washing machine PW 5064 MOPSTAR 60 To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan Installation plan Washing machine PW 6055 AV/LP PW 6065 AV/LP To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation

More information

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan Installation plan Tumble dryer PT 5137 WP PT 7137 WP To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

Tumble dryer PT 5135 C PT 7135 C. en - GB. Installation plan

Tumble dryer PT 5135 C PT 7135 C. en - GB. Installation plan Installation plan Tumble dryer PT 5135 C PT 7135 C To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

Installation plan: PG Mat. no Version 00 US

Installation plan: PG Mat. no Version 00 US Installation plan: PG 8504 Mat. no. 10 344 110 Version 00 US Technical data sheet PG 8504 Legend: Circled, bold-type abbreviations: Connection required Abbreviations surrounded by broken circle: Connection

More information

Installation plan Commercial Washing Machine PW 413 PW 418

Installation plan Commercial Washing Machine PW 413 PW 418 Installation plan Commercial Washing Machine PW 413 PW 418 To avoid the risk of accidents or damage to the machine, it is essential to read these instructions before it is installed and used for the first

More information

Installation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ

Installation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ Installation plan: PG 8581 PG 8583 Mat. no. 10 390 400 Version 02 GB, IE, AU, NZ Technical data sheet Washer-disinfector PG 8581-8583 Legend: Circled, bold-type abbreviations: Connection required Abbreviations

More information

Tumble dryer PT 5136 PT en - GB. Installation plan

Tumble dryer PT 5136 PT en - GB. Installation plan Installation plan Tumble dryer PT 5136 PT 7136 To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Installation Plan. Professional Dishwasher PG Mat. no.: en - US Installation Plan Professional Dishwasher PG 8056 Mat. no.: 10 251 400 en - US Installation instruction Observe installation instructions when installing machine. This dishwasher is suitable for residential

More information

Installation Plan. Laboratory Glassware Washer. en US PG 8583 CD. M. Nr

Installation Plan. Laboratory Glassware Washer. en US PG 8583 CD. M. Nr Installation Plan Laboratory Glassware Washer PG 8583 CD M. Nr. 10 341 990 en US Installation Instructions Please read and observe the instructions in the operating instruction manual and the service documents

More information

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Installation Plan. Professional Dishwasher PG Mat. no.: en - US Installation Plan Professional Dishwasher PG 8061 Mat. no.: 09 838 370 en - US Installation instruction Observe installation instructions when installing machine. This dishwasher is only suitable for commercial

More information

Installation Plan Washing Machine PW 811 PW 814 PW 818

Installation Plan Washing Machine PW 811 PW 814 PW 818 Installation Plan Washing Machine PW 811 PW 814 PW 818 To prevent accidents and machine damage, read these instructions before installation or use. en-us M.-Nr. 10 668 670 Contents Installation and planning

More information

Installation plan PG 8581 PG 8582 PG en - US

Installation plan PG 8581 PG 8582 PG en - US Installation plan PG 8581 PG 8582 PG 8583 It is essential to read the operating instructions as well as the service documentation before the machine is installed or used for the first time. en - US M.-Nr.

More information

Installation plan. Washer disinfector. en AU, NZ PG 8583 CD. M. Nr

Installation plan. Washer disinfector. en AU, NZ PG 8583 CD. M. Nr Installation plan Washer disinfector PG 8582 CD PG 8583 CD M. Nr. 10 390 830 en AU, NZ Installation notes Please read and observe the instructions in the operating instruction manual and the service documents

More information

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control manual W365H, W375H, W305H, W330H, W380H, W3240H, W3300H Exacta & Clarus Control 438 9200-0 06.34 Contents 3 Contents Technical data... :... 2: Transportation and unpacking... 2: Siting and floor... 3:

More information

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17 VIESMANN VITOCELL 300-V Vertical DHW cylinder 130to500litrecapacity Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 17 VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder

More information

Installation manual Washer extractor

Installation manual Washer extractor Installation manual Washer extractor W575N, W585N, W5105N, W5130N, W5180N, W5250N, W5330N Type W3... Original instructions 438 9055-30/EN 2016.12.09 Contents Contents 1 Safety Precautions...5 1.1 General

More information

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions Fan-and-filter units Features Fan-and-filter units are ideal for dissipating heat loads costeffectively. The pre-requisite is that the ambient air must be relatively clean and with a temperature below

More information

hinge right B 1 85 cm + 6,5-7 cm max. height of the device feet B cm B 3 85 cm D 2 75 cm (with a maximum opening angle of 170 )

hinge right B 1 85 cm + 6,5-7 cm max. height of the device feet B cm B 3 85 cm D 2 75 cm (with a maximum opening angle of 170 ) Space requirements Fig. 1: Fore view, door hinge left Fig. 2: Upper view, door hinge left (D1, D2) and door hinge right Table 1: Space requirements Cliniclave 45 Dimensions Cliniclave 45 Width Height Height

More information

TOP AND CONSOLE PARTS

TOP AND CONSOLE PARTS TOP AND CONSOLE PARTS 27" ELECTRIC DRYER 6 12 Printed in U.S.A. (GG)(bay) 1 Part No. Rev. A TOP AND CONSOLE PARTS 1 Literature Parts W10392124 Installation, Diagnostic Guide W10388780 Guide, Use & Care

More information

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9

More information

>40 80 mm. Dishwasher EN Installation instructions. Appliance components >40. Recess for pipes >80. Front panel/decorative system.

>40 80 mm. Dishwasher EN Installation instructions. Appliance components >40. Recess for pipes >80. Front panel/decorative system. Dishwasher EN Installation instructions Before installation, please read the safety precautions on the reverse side! Appliance components Recess for pipes >40 >80 >40 80 mm Front panel/decorative system

More information

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT 1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»

More information

Installation plan Heat pump dryer PT 8203 SL WP

Installation plan Heat pump dryer PT 8203 SL WP Installation plan Heat pump dryer PT 8203 SL WP To avoid the risk of accidents or damage to the machine, it is essential to read these instructions before it is installed and used for the first time. en

More information

Installation manual Washer extractor

Installation manual Washer extractor Installation manual Washer extractor W555H Type W.55.H Original instructions 438 9054-30/EN 2017.11.06 Contents Contents 1 Safety Precautions...5 1.1 General safety information...6 1.2 Commercial use

More information

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 0 l capacity Datasheet Part no. and prices: see pricelist VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder made from stainless steel 5/2012 Product

More information

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2 Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40

More information

Professional Laundry Solutions

Professional Laundry Solutions Professional Laundry Solutions Miele Washer-Extractors High Spin Speeds Miele has increased its washers capabilities to extract more water with high spin speeds and the highest G-forces (over 500 g s)

More information

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA Installation and service instructions for contractors VIESMANN Vitocell 340-M/360-M Type SVKA Type SVSA Combi cylinder 750 and 950 litre capacity VITOCELL 340-M/360-M 4/2009 Please keep safe. Safety instructions

More information

Storage tank size Rated volume [l] Actual volume [l]

Storage tank size Rated volume [l] Actual volume [l] 10 Technical Data Volumes and heat loss Storage tank size 356 456 656 756 956 Rated volume [l] 350 450 650 750 950 Actual volume [l] 365 448 623 695 886 Hot water standby volume [l] Economy Standard Comfort

More information

Installation Instructions

Installation Instructions Installation Instructions Gas Cooktop KM 404 KM 406 To prevent accidents and machine damage, read the operating instructions before installation or use. UV M.-Nr. 05 060 881 WARNING: If the information

More information

INSTALLATION AND INITIAL OPERATING INSTRUCTIONS

INSTALLATION AND INITIAL OPERATING INSTRUCTIONS Professional kitchens INSTALLATION AND INITIAL OPERATING INSTRUCTIONS ELRO stationary kettle with integrated mixer Model JRW 2200 ELRO-WERKE AG Date: 07.09.11 checked: Initials: Document No: Register:

More information

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions GRUNDFOS INSTRUCTIONS Sololift2 C-3 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS

More information

Washer extractor. Features and benefits. Main options. Main specifications W4400H, W4600H 45/100 65/ / 54

Washer extractor. Features and benefits. Main options. Main specifications W4400H, W4600H 45/100 65/ / 54 Washer extractor W4400H, W4600H Features and benefits Clarus Control programmable microprocessor with 9 fixed and up to 192 programs to allow free programming High extraction for efficient dewatering Frequency-controlled

More information

Moisture inside the drum is due to final testing.

Moisture inside the drum is due to final testing. Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport safety devices Water connection depending on model The washing machine

More information

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007 Assembly- and Usermanual Rainmaker Code No. 99-97-1729 GB Edition: 09/2007 Table of contents Page I 1 Overview and system specifications.................................. 1 1.1 Purpose of Evaporative

More information

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler Installation instructions for contractors VIESMANN Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler VITORONDENS 200-T 6/2011 Dispose after installation. Safety instructions Please

More information

Removing shipping locks

Removing shipping locks y Safety instructions Scope of delivery Moisture in the drum is due to end inspection. Removing shipping locks Water connection l The washing machine is heavy - lift with caution. Frozen hoses can tear/burst.

More information

High spin. Maximum efficiency, energy saving and environmentally friendly. G FACTOR = 350 / 450 SOFT MOUNTED

High spin. Maximum efficiency, energy saving and environmentally friendly. G FACTOR = 350 / 450 SOFT MOUNTED G FACTOR = 350 / 450 SOFT MOUNTED High spin Maximum efficiency, energy saving and environmentally friendly. Especially designed for those laundries where the quality of the process and the energy and water

More information

High spin hygienic barrier washer-extractors

High spin hygienic barrier washer-extractors High spin hygienic barrier washer-extractors IB265 - IB332 - IB442 - IB663 Features Stainless steel body and grey painted side legs Freestanding, high spin Oversized frame, bearings and drum Large drain

More information

LK Electric Boiler - 4,5

LK Electric Boiler - 4,5 LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered

More information

27" GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/ Whirlpool Corporation Part No. W Rev.

27 GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/ Whirlpool Corporation Part No. W Rev. 27" GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/2014 2014 Whirlpool Corporation Part W10710285 Rev. A TOP AND CONSOLE PARTS 05/13/2014 2 Part W10710285 Rev. A TOP AND CONSOLE

More information

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date. Issued July 2004 No. U-101 FRESH MASTER HAND BOOK (For HONG KONG) FOR DEALERS Model: GUF-50RDH3 GUF-100RDH3 Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the

More information

Moisture inside the drum is due to final testing.

Moisture inside the drum is due to final testing. Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport braces Water connection depending on model The washing machine is heavy

More information

WARNING CAUTION. Approval Marks. Protection Class Ι TECHNICAL DATA. CCA certified

WARNING CAUTION. Approval Marks. Protection Class Ι TECHNICAL DATA. CCA certified LEI STER UNI FLOOR Ref.95250 www. romus. f r LEI STER UNI FLOOR Ref.95250 www. romus. f r WARNING Danger! Unplug the tool before opening it, as live components and connections are exposed. Incorrect use

More information

Installation manual for room air conditioner

Installation manual for room air conditioner Installation manual for room air conditioner HSU-26HEK03/R2(D)/I HSU-35HEK03/R2(D)/I HSU-53HEK03/R2(D)/I HSU-71HEK03/R2(D)/I HSU-26HEK03/R2(D)/O HSU-35HEK03/R2(D)/O HSU-53HEK03/R2(D)/O HSU-71HEK03/R2(D)/O

More information

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw Technical Guide Installation, Operation and Care EP E series 7 step electric boilers 26 and 42 kw Arkelstorpsvägen 88, 291 94 KRISTIANSTAD Tel +46 44-22 63 20, Telefax +46 44-22 63 58 e-mail: info@varmebaronen.se

More information

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMPS OPERATING & MAINTENANCE INSTRUCTIONS SUBMERSIBLE WATER PUMPS Model Nos. HIPPO-3 and 3A 6/97 Thank you for purchasing this CLARKE, HIPPO Submersible Pump. These highly efficient pumps are designed for pumping

More information

27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/ Maytag Part No. W Rev. A

27 Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/ Maytag Part No. W Rev. A 27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/2013 2013 Maytag Part W10617393 Rev. A TOP AND CONSOLE PARTS 05/31/2013 2 Part W10617393 Rev. A TOP AND CONSOLE PARTS Part Description

More information

27" GAS DRYER MODELS: 7MWGD87HEDC0 (Chrome Shadow) 08/19/ Whirlpool Corporation Part No. W Rev. A

27 GAS DRYER MODELS: 7MWGD87HEDC0 (Chrome Shadow) 08/19/ Whirlpool Corporation Part No. W Rev. A 27" GAS DRYER MODELS: 7MWGD87HEDC0 (Chrome Shadow) 08/19/2014 2014 Whirlpool Corporation Part W10738517 Rev. A TOP AND CONSOLE PARTS 08/19/2014 2 Part W10738517 Rev. A TOP AND CONSOLE PARTS 1 Literature

More information

BOILING PANS GAS & ELECTRICS

BOILING PANS GAS & ELECTRICS PREMIUM BOILING PANS GAS & ELECTRICS MANUFACTURER'S INSTRUCTIONS Part A: Technical data Part B: Installation manual - WARNING - Installation and repairs must be carried out by personnel approved by the

More information

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses. Installation and service instructions for contractors VIESMANN Solar-Divicon and solar pump assembly Safety instructions Please follow these safety instructions closely to prevent accidents and material

More information

Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217

Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217 Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217 To avoid the risk of accidents or damage to the machine, it is essential to read these instructions before it is installed and used for

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2 INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWS50BV EKHWS00BV EKHWS00BV EKHWS00BZ EKHWS00BZ 4 5 6 x x x 4x x + x 00 7 05 0 45 5 400 5 6 00 /4" FBSP 6 H 0 H4 H 0 H 0

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine

More information

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 MAKING MODERN LIVING POSSIBLE Installation Guide SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 www.eh.danfoss.com Table of Contents 1 Introduction............................................. 3 1.1 Self-limiting

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

27" GAS DRYER MODELS: MGD7100DW0 (White) MGD7100DC0 (Chrome Shadow) 05/08/ Maytag Part No. W Rev. A

27 GAS DRYER MODELS: MGD7100DW0 (White) MGD7100DC0 (Chrome Shadow) 05/08/ Maytag Part No. W Rev. A 27" GAS DRYER MODELS: MGD7100DW0 (White) MGD7100DC0 (Chrome Shadow) 05/08/2014 2014 Maytag Part W10712329 Rev. A TOP AND CONSOLE PARTS 05/08/2014 2 Part W10712329 Rev. A TOP AND CONSOLE PARTS Part Description

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions Installation, Operating and Servicing Instructions Opus 800 Electric Salamander OE8303, OE8304 Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number: Dealer:

More information

DOMESTIC HOT WATER TANK

DOMESTIC HOT WATER TANK Operating Manual UK DOMESTIC HOT WATER TANK SOLAR DOMESTIC HOT WATER TANK Accessories for heat pumps Please read first This operating manual provides important information on handling the unit. It is an

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3 INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWE50AV EKHWET50AV EKHWE00AV EKHWE00AV EKHWE00AZ EKHWE00AZ 4 5 6 7 x x x 4x x x x EKHWE50~00 EKHWET50 50 50 0 0 00 50 700

More information

The sealless FLUX F 424

The sealless FLUX F 424 The sealless FLUX F The liquids to be pumped are abrasive, but they do not leave any deposits. Dry running of the pump must not cause any problems. You are looking for a lightweight, general purpose pump

More information

42PHW / 42PHQ 42PHQ...K

42PHW / 42PHQ 42PHQ...K 42PHW / 42PHQ 42PHQ...K INSTALLATION MANUAL Split system Hi-Wall indoor unit For operation and maintenance instructions of this unit, as well as installation instructions of the outdoor unit, refer to

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these

More information

1. Description. 2. List of Accessories included

1. Description. 2. List of Accessories included 1. Description This unit is a pump that will clear the waste from a shower and washbasin, bath, washing machine, glass washer and a sink in a light commercial situation. The unit will start automatically.

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL t Thank you for choosing Aqua inverter heat pump. This manual provides you necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent

More information

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection) RESIDUAL CURRENT DEVICE (RCD) - Contents 1. Introduction 2. General 3. RCCB (residual current operated circuit-breaker without integral overcurrent 4. RCBO (residual current operated circuit-breaker with

More information

Installation Instructions

Installation Instructions Installation Instructions KFN 9855 ide en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations

More information

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Installation instructions VITODENS 200-W. for contractors Installation instructions for contractors VIESMANN Vitodens 200-W Type WB2C, 45 and 60 kw Wall mounted gas condensing boiler Natural gas and LPG version VITODENS 200-W 1/2010 Dispose after installation.

More information

Technical information for installation and operation

Technical information for installation and operation Technical information for installation and operation PR 24002.65 12-04-2016 Subject to technical modifications LogoFresh 100 & 120 fresh water station Electronically controlled GB Meibes System-Technik

More information

User Manual. 60 cm Knob control 4 zone ceramic cooktop

User Manual. 60 cm Knob control 4 zone ceramic cooktop User Manual HHC601 60 cm Knob control 4 zone ceramic cooktop OTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most

More information

INSTRUCTIONS FOR USE TUMBLE DRYER

INSTRUCTIONS FOR USE TUMBLE DRYER INSTRUCTIONS FOR USE TUMBLE DRYER IMPORTANT PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE USING THIS APPLIANCE. KEEP THEM IN A SAFE PLACE FOR FUTURE REFERENCE. IMPORTANT USER INFORMATION This tumble

More information

Installation Instructions Front-Loading Multi-Load Commercial Washers

Installation Instructions Front-Loading Multi-Load Commercial Washers Installation Instructions Front-Loading Multi-Load Commercial Washers MXS20, MXS25, MXS30, MXS40, MXS55, MXS65 MXR20, MXR25, MXR30, MXR40, MXR55, MXR65 WASHER SAFETY... 2 INSTALLATION REQUIREMENTS... 3

More information

TECHNOSKLO Ltd. Držkov

TECHNOSKLO Ltd. Držkov TECHNOSKLO Ltd. Držkov Distillation apparatus for producing of distilled water TYPE DP 4000 Operating manual TECHNOSKLO Ltd. 468 24 Držkov 135 Czech Republic tel.: 00420 483 346 403 fax: 00420 483 385

More information

Please read operating instructions carefully before use and keep for further reference.

Please read operating instructions carefully before use and keep for further reference. GB OPERATING INSTRUCTIONS LEISTER Welding-Pen A LEISTER Welding-Pen S Hot air tools Please read operating instructions carefully before use and keep for further reference. APPLICATION The LEISTER Welding-Pen

More information

WARNING CAUTION. Approval Marks. Protection Class I TECHNICAL DATA. CCA certified

WARNING CAUTION. Approval Marks. Protection Class I TECHNICAL DATA. CCA certified LEI STER UNI FLOOR DI GI TAL Ref.95252 www. romus. f r WARNING Danger! Unplug the tool before opening it, as live components and connections are exposed. Incorrect use of hot air tools can present a fire

More information

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com

More information

Air/water - Heat pumps

Air/water - Heat pumps Air/water - Heat pumps Installation of a NIBE air/water heat pump can lead to your energy consumption for heating being reduced by up to 50%, in comparison to conventional heating systems. Areas of Use

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL Thank you for choosing inverter heat pump. This manual provides you necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent

More information

The sealless FLUX F 424

The sealless FLUX F 424 The sealless FLUX F The liquids to be pumped are abrasive, but they do not leave any deposits. Dry running of the pump must not cause any problems. You are looking for a lightweight, general purpose pump

More information

Installation manual. Tumble dryer T5675. Type N /AU Installation manual in original language

Installation manual. Tumble dryer T5675. Type N /AU Installation manual in original language Installation manual Tumble dryer T5675 Type N2... 438 9054-20/AU Installation manual in original language 2014.06.24 Additional safety instructions and warnings 3 Additional safety instructions and warnings

More information

Washer-Extractor. Parts. Refer to Page 4 for Model Identification. Part No. D1662

Washer-Extractor. Parts. Refer to Page 4 for Model Identification. Part No. D1662 Washer-Extractor Refer to Page 4 for Model Identification Parts Part No. D1662 www.alliancelaundry.com April 2015 PARTS ORDERING INFORMATION If literature or replacement parts are required, contact the

More information

BACE cm ceramic electric cooktop GECE cm ceramic electric cooktop

BACE cm ceramic electric cooktop GECE cm ceramic electric cooktop BACE9004 90cm ceramic electric cooktop GECE9004 90cm ceramic electric cooktop 1 BHI609 60cm Front touch control induction zone hob 2 User Manual for your BACE9004 GECE9004 90 cm Front touch control 4 radiant

More information

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A Installation instructions for contractors VIESMNN Vitocell 300-V/W Type EVI- DHW cylinder with internal indirect coil 160 to 500 l VITOCELL 300-V/W 3/2017 Dispose after installation. Safety instructions

More information

Installation Instructions

Installation Instructions Installation Instructions Gas Cooktop KM 360 To prevent accidents and machine damage, read these instructions before installation or use. UV M.-Nr. 06 390 460 WARNING: If the information in this manual

More information

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure

More information

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4 Installation Operation Maintenance Ductable water unit FWD 08-12 - 20-30 - 45 General Information Foreword These installation, operation and maintenance instructions are given as a guide to good practice

More information

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

Flo~mate Mains Boost Pump Installation & Maintenance Instructions ~ Flo~mate Mains Boost Pump Installation & Maintenance Instructions Please leave this instruction booklet with the owner as it contains important guarantee, maintenance and safety information FOR POSITIVE

More information

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent CLAS HE WALL-HUNG HIGH EFFICIENCY GAS BOILERS Elegant, efficient and intelligent The high efficiency boiler that saves on energy and costs With specified intelligence, CLAS HE adapts to the householder's

More information

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45 U tube models PTU 09, 2, 5, 25, 30, 35, 40, 45 & single linear tube models PTS 09, 2, 5, 25, 30, 35, 40, 45 installation, servicing & operating instructions INSTALLATION, SERVICING AND OPERATING INSTRUCTIONS

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR32--2 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 9612212 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9612212/cr-32--2-a-f-a-e-hqqe.html

More information

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference) Colorado SCR Electric Towel Radiator Operating and Installation Instructions (Read these instructions carefully and retain for future reference) Models SCR 300 300W SCR 450 450W SCR 750 750W NOTE A qualified

More information

ROTAMAT THE ROTAMAT. The ideal solution for coating of mass-produced small parts WE IMPROVE SURFACES

ROTAMAT THE ROTAMAT. The ideal solution for coating of mass-produced small parts WE IMPROVE SURFACES ROTAMAT THE ROTAMAT The ideal solution for coating of mass-produced small parts WE IMPROVE SURFACES The Rotamat a coating system with unlimited possibilities DECORATIVE COATING Surface refinement with

More information

For more Parts Information:

For more Parts Information: For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series

More information

green&clean multi-rinse Rack Type, Energy Saving Device, medium

green&clean multi-rinse Rack Type, Energy Saving Device, medium ITEM # MODEL # green&clean multi-rinse Rack Type, Energy Saving Device, medium dryer, electric, 150r/h, NAME # SIS # AIA # 535025 (EMR15MELE) Short Form Specification Item No. APPROVAL: Multi-rinse Rack

More information