THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION
|
|
- Kerrie Hodge
- 4 years ago
- Views:
Transcription
1 CFSA CSSD Conference Durban ICC Wednesday 8 th March 2017 Using technology to improve patient safety THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION Helen Loudon Independent Infection Prevention Practitioner Helen Loudon Risk Management Nurse Specialist
2 Treat your investment with care and respect Used surgical instruments are like dirty dishes the longer they dry out in the sink, the harder they are to clean! Cleaning is the single most important step in making a medical device safe and ready for reuse Ultrasonic cleaning is considered to be far superior and more reliable than manual cleaning If undertaken correctly, 99.9% soil will be removed in 3-5 minutes 2
3 Safety challenges Instruments and minimally invasive equipment is becoming more complex Equipment is a huge capital investment Microbial biofilm and organic soil are resistant to manual removal Deadly pathogens are then spread through indirect contact transmission via hard to reach surfaces, lumens and crevices Pressured turn around times! 3
4 Bioburden on equipment surfaces under high magnification 4
5 How do ultrasonic cleaners work? Ultrasonic cleaners comprise 3 main parts: transducer = a device which converts one form of energy into another (eg. electricity to sonic waves ) ultrasonic generator cleaning tank Ultrasonic cleaning works through cavitation. The high intensity sound waves make tiny bubbles on the surfaces of the instruments. These bubbles expand until they become unstable and collapse or implode. These shock waves physically loosen and remove micro-organisms and other adherent debris from even the most inaccessible surfaces of a soiled instrument 5
6 Types of instruments which should undergo ultrasonic cleaning Ultrasonic-Cleaning
7 Important factors which affect ultrasonic cleaning Higher powered (Ie. wattage) machines will produce faster cleaning results The frequency of the sound waves will affect the effectiveness of the cavitation force The temperature, viscosity, density, vapor pressure and surface tension of the cleaning solution are critical to the effectiveness of ultrasonic cleaning Machines with lower frequency (sound waves) machines may be noisier - BUT, higher frequency sound waves will produce weaker cavitation (the collapsing power of each bubble) and the risk of less effective cleaning So BIGGER is not always BETTER seek advice on ultrasonic cleaners best suited to the type of equipment you need to clean 7
8 The cleaning solution A critically important and often neglected aspect! ph neutral (eg ) enzymatic detergent Low foaming Biodegradable safe to discard to sewer HIGH surface tension Ability to hold organic debris in solution NB! Gross debris should be rinsed off beforehand Do NOT let blood/fluids dry on instrumentation Change the water in the U/S cleaner frequently Run the U/S cleaner for 5-10 minutes to degas the water (to remove dissolved oxygen) before adding instruments 8
9 Good practice for ultrasonic cleaning Follow the equipment manufacturer s recommendations for the safest cleaning method Use the detergent solution recommended by the U/S bath manufacturer Keep used instrumentation moist until cleaned (Eg. with enzymatic cleaners or sterile pour H 2 O) Remove gross soiling with manual cleaning beforehand Use a mesh tray and don t exceed the recommended equipment capacity Ensure box locks, hinges and ratchets are open during soaking and cleaning Flush the air out of lumens with the cleaning solution Cover the tank in use to prevent aerosols and reduce noise 9
10 WARNINGS Blood, body fluids and normal saline are highly corrosive and will rust and pit instruments Quartz, silicon, plastic, carbon steel, gold or chromium plated instruments, endoscopic lenses and powered instruments should not be cleaned ultrasonically Do NOT place instruments directly onto the floor of the tank this will interfere with the production of sound waves and cause friction damage to the equipment Do NOT stack, fail to open/dismantle instruments or overload the tank 10
11 The impact of water quality A water quality assessment (by local municipality) should be undertaken periodically and after major maintenance to the water supply Excessively hard water will spot or stain instruments and the chlorine in tap water will cause pitting of instrument surfaces. Final rinsing should be undertaken with treated (de-ionized) water. De-ionized water removes soil and detergent residues more efficiently De-ionizing water removes dissolved minerals, iron and particles which could harm instruments. Adding water softeners removes calcium and magnesium ions which cause spotting on instruments. 11
12 Pre-purchasing questions 3 1. What are the dimensions of the ultrasonic cleaner? Is the size of its processing tank sufficient to accommodate the facility's soiled instruments? 2. How much power does the ultrasonic cleaner produce? Does the cleaner feature one power setting, or it is equipped with different power settings to process lightly soiled, heavily-soiled instruments, and delicate instruments? 3. What is the ultrasonic cleaner's frequency setting? Can it be adjusted? 4. What is the ultrasonic cleaner's standard cleaning time? Can this time be adjusted to permit extended cleaning for big loads and heavily-soiled instruments? 5. Does the manufacturer have any data to support its cleaning effectiveness? 6. Is the ultrasonic cleaner indicated for only a few types of instruments? What types of instruments, if any, are contraindicated? 12
13 Thank you! C mon, make my day wash your hands!
14 1. Ultrasonic cleaning effect on surgical instruments (30 secs) 2. Testing your ultrasonic cleaner the foil test (2 mins)
15 References and resources 1. CSSD Forum of South Africa Standard Operating Procedures Manual. SOP No. 32 Prepare, Load and Operate Ultrasonic Cleaner; SOP No. 33 Validating an Ultrasonic Cleaner 2. Shelnutt T. Ultrasonic Cleaners. Infection Control Today. September Muscarella L.F. The Benefits of Ultrasonic Cleaning. Infection Control Today. May The Association of Peri-operative Nurses. Recommended Practices for the Care and Cleaning of Surgical Instruments and Powered Equipment. AORN Journal 1997, Volume 65, Issue 1, Pages Kaiser H. McDonnell G. et al. Water quality and Reprocessing Instruments. Infection Control Today. May Instrument Reprocessing Working Group (10 th Edition). Reprocessing of instruments to retain value. 7. SAFMED Newsletter April Ultrasonic Cleaning. 15
When you sterilize an instrument set, you know what the standards are.
Sterilization & Infection Control The importance of cleaning in earnest A regular column on sterilization and infection control issues. When you sterilize an instrument set, you know what the standards
THE BASICS OF DECONTAMINATION
THE BASICS OF DECONTAMINATION Objectives Review the basic factors that impact cleaning and decontamination of surgical devices Present the fundamentals of manual and automatic cleaning Review various cleaning
SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS
SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS CAUTION: The following instructions are for all Sklar Coated stainless steel instruments. Read instructions prior to use. Improper
2015 Myco Industries, Inc Fax:
Endoscope Cleaning and Handling It is highly important that you manually clean the endoscope immediately after it is removed from the patient, BEFORE it is automated or manually disinfected. Cleaning your
CLEANING INSTRUCTIONS
Reusable Instrument Care Manual Pagoda Pedicle Screw System Manufacturer Ortho Development Corporation 12187 South Business Park Drive Draper, UT 84020 Phone 801-553-9991 Fax 801-553-9993 www.orthodevelopment.com
Accessories. Maybachstraße. Symmetry Fax: Revised 10/15
Recommended Care, Cleaning and Sterilization Instructions for Reusable Instruments & Accessories Symmetry Surgical Inc. 3034 Owen Drive, Antioch, TN 37013 USA 1-800-251-3000 Fax: 1-615-964-5566 www.symmetrysurgical.com
ULTRASONIC (SONIC) CLEANING ENHANCES THE INSTRUMENT
CRCST Self-Study Lesson Plan Lesson No. CRCST 153 (Technical Continuing Education - TCE) Sponsored by: by Ava Griffin, BSN, RN, CNOR CSP Educator University of Chicago and Patti Koncur IAHCSMM Education
Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK
Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK Irrespective of where the decontamination is performed or who it is performed by the
CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization
CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray Equipment Cleaning and Sterilization Table of Contents 1. WARNINGS AND PRECAUTIONS... 3 2. INSTRUMENT PREPARATION... 3 3. CAVITY PREPARATION
BioSonic Ultrasonic Cleaning Systems. biosonic.coltene.com
BioSonic Ultrasonic Cleaning Systems biosonic.coltene.com 2018 BioSonic An essential part of your Infection Control System Three Decades of Trusted Technology BioSonic UC150 BioSonic UC125 BioSonic UC50DB
GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED
GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE Tested for optimal cleaning and performance ciso 15883 VALIDATED 2 GETINGE CLEAN GETINGE CLEAN THE ANSWER TO YOUR CLEANING PROBLEMS What does the word
CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization
CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization 1. WARNINGS AND PRECAUTIONS 1.1. Caution should be exercised when handling instruments with sharp points, or cutting/drilling
المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية
1. POLICY STATEMENT: Cleaning, decontamination and sterilization method should be done in CSSD service facility not in the end user department side. 2. PURPOSE: To ensure the proper way of collections,
The Principles, The Process, and The Results:
The Principles, The Process, and The Results: Presented by: Fred Alston, CSPDT Eastern Region Clinical Sales and Support Manager April 21, 2017 I am an employee of Healthmark Industries Fraser, Michigan
Instructions for Use Spinal Punches IFU
Indications for use Spinal punches are manually operated instruments indicated for cutting or biting bone during surgery involving the skull or spinal column. Contraindiciations Instruments should not
CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization
CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization 1. WARNINGS AND PRECAUTIONS 1.1. Caution should be exercised when handling instruments with sharp points, or cutting/drilling
CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L
1 2 Ideal for cleaning surgical, medical, dental instruments and equipment. Available in various sizes. Before placing instruments into the Ultrasonic Cleaner a degas cycle should be run. Then a clinical
CLEANING AND HANDLING OF WRIGHT INSTRUMENTS
CLEANING AND HANDLING OF WRIGHT INSTRUMENTS 150824-0 The following languages are included in this packet: English (en) Deutsch (de) Nederlands (nl) Français (fr) Español (es) Italiano (it) Português (pt)
SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY
SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY SUBJECT: ULTRASONIC CLEANER MONITORING DAILY DEPARTMENT: CPD, CSSD, SPA, MDRD, SPD, dental offices, medical offices and department using
Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions
Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing Instructions for Use. Description and Intended Use Integra LifeSciences Corporation reusable surgical device sets consist of various
PERFORM Operating Document
PERFORM Operating Document Use and Maintenance of Tuttnauer Table-Top Autoclave PC-POD-CA-006-v03 Revision History Version Reason for Revision Date 01 New POD 13-Aug-13 02 POD Section 3.1.3 and 3.2 revised
WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY
Sonic Irrigator SA Automated Cannulated Instrument Reprocessing Sonic Irrigation Twin Cannulated Pulse Flush Systems Load performance optimisation Independent process monitoring EN ISO 15883/HTM 2030 compliant
Surgical Instrument Cleaning Process
Surgical Instrument Cleaning Process The Universal Processing Solution The Surgical Instrument Enzyme Detergent Lubricant Cleaners The Surgical Instrument Detergent Enzyme Lubricant Cleaner will cut costs.
Aesculap Implant Systems
Aesculap Implant Systems Aesculap Implant Systems Orthopedics USA Instructions for Use/Technical Description Page 1 of 14 Symbols on product packages Caution, general warning symbol Caution, see documentation
Aesculap Implant Systems
Aesculap Implant Systems Aesculap Implant Systems Orthopedics USA Instructions for Use/Technical Description Page 1 of 16 Symbols on product packages! Caution, general warning symbol Caution, see documentation
CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com
CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY natoli.com PROPER TOOL CLEANING IS CRUCIAL EXTEND TOOL LIFE DECREASE PRESS DOWNTIME REDUCE PRODUCTION-RELATED COSTS IMPROVE TABLET QUALITY Tablet
Cleaning & Sterilization
Handpieces & Attachments Instruments Cleaning & Sterilization System 7 System 6 System 5 CD4 CD3 SABO 2 SABO RemB CORE TPS Processing Instructions User/Patient Safety all contribute to the efficacy of
User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories
User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories Table of Contents 1. Intended Use Statement... 3 2. Proper Use... 3 3. General Information...
Before digging into the 10 things you should know let s start with a brief explanation of the process.
Ultrasonic cleaners are unsurpassed when it comes to removing contaminants from virtually any hard surface that can be safely immersed in a cleaning solution. The challenge is selecting the correct ultrasonic
INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)
INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS) 1 INTRODUCTION This paper is intended to give general
IMPORTANT INFORMATION ON THE DEPUY SYNTHES
For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE DEPUY SYNTHES MatrixNEURO RECONSTRUCTION MESH, STERILE MatrixNEURO PREFORMED MESH, STERILE GP2949-B-CAN DESCRIPTION The DePuy Synthes
PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE
THEATRE AND STERILE PROCEDURES WALLS/TILES - Wash all surfaces from top to bottom using F10CLXD, rinse with - Wash off visible dirt (e.g. blood) using F10CLXD CHAIRS - Trigger spray using F10CL and wipe
Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)
Fiber Optic Cables Instructions for Use and Processing Instructions DFU-950-0031-00 Fiber Optic Cables Made in USA Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904) 737 7611
RECOMMENDATIONS FOR CLEANING DEVICES
RECOMMENDATIONS FOR CLEANING D E C O N TA M I N AT I O N A N D S T E R I L I Z AT I O N O F M E D A C T A I N T E R N A T I O N A L O R T H O P E D I C DEVICES 1 This document was prepared to provide cleaning,
Sterile Processing. Knowledge, Skills, Competencies. Terri Goodman, PhD, RN
Sterile Processing Knowledge, Skills, Competencies Terri Goodman, PhD, RN This publication is intended to be a helpful information resource, and reflects the expert advice and views of the author. It is
Instrument Cleaning Chemistries Automated Washing Process
Instrument Cleaning Chemistries Automated Washing Process Procedure Pre-cleaning Prolystica Enzymatic Presoak and Cleaner Klenzyme Enzymatic Presoak and Cleaner ZolvStat Multi-Enzymatic Detergent Pre-Klenz
PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS
GENERAL - BEST PRACTICE CLEANING EQUIPMENT Sweep or rinse away loose debris. On floors, use a dust-attracting mop, not a broom Where possible, make use of vacuum (Clean bag daily) Remove spills (feaces,
Cavitator Ultrasonic Cleaners
Cavitator Ultrasonic Cleaners Instruction Manual (for model # 18G) 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
DEVICES THAT HAVE NOT BEEN ADEQUATELY CLEANED CANNOT
Lesson No. CIS 244 (Instrument Continuing Education - ICE) Sponsored by: by Donna Swenson, BS, CRCST, CHL, CSPDM Clinical Operations Manager Synergy Health PLC, Tampa, FL DECONTAMINATION LEARNING OBJECTIVES
Operating / User Manual
UniARM Surgical Support System Operating / User Manual Version 1.1 MITAKA KOHKI Co., Ltd. 1. Introduction Introduction Thank you for purchasing the UniARM for use in surgical procedures. To use the device
PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS
GENERAL - BEST PRACTICE CLEANING EQUIPMENT Sweep or rinse away loose debris. On floors, use a dust-attracting mop, preferably not a broom Where possible, make use of vacuum (Clean bag daily) Remove spills
Decontamination. CIS Self-Study Lesson Plan Lesson No. CIS 244 (Instrument Continuing Education - ICE)
Lesson No. CIS 244 (Instrument Continuing Education - ICE) Sponsored by: by Donna Swenson, BS, CRCST, CHL, CSPDM Clinical Operations Manager Synergy Health PLC, Tampa, FL Decontamination Learning Objectives
PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE
THEATRE AND STERILE PROCEDURES WALLS/TILES - Wash all surfaces from top to bottom using F10SCXD, rinse with - Wash off visible dirt (e.g. blood) using F10SCXD CHAIRS - Trigger spray using F10SC and wipe
CLEANING OF INSTRUMENTS
Disclaimer: This article is provided to Keir Surgical Ltd. by SPS Medical. The information in this document should be used in conjunction with your hospital or institution s cleaning and decontamination
INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:
INSTRUCTION MANUAL Laboratory Equipment Pty Ltd email: sales@labec.com.au Ph: 02 9560 2811 Fax: 02 9560 6131 www.labec.com.au 2014 FXP16M LABORATORY EQUIPMENT PTY LTD 26 30 Farr St, Marrickville, NSW 2204
Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012
Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods 11.40-12.30 27 th July 2012 Chirurgie-Instrumenten-Arbeitsgruppe Berlin Dr. med. Dipl.-Ing. Thomas W. Fengler What is so manual
Cavitator Ultrasonic Cleaner Instruction Manual
Cavitator Ultrasonic Cleaner Instruction Manual Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES
INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES Contents: Pagina 1 Introduction...2 2 Treatment instructions...2 3 Cleaning...2 3.1 Place of use...4
Contents. Ultrawave baths are manufactured in the UK and conform to exacting international standards.
Contents Contents... 1 Safety Instructions... 1 Installation... 3 Quick Guide... 4 Manual I Control Panel Instructions (U50, U95, U100, U300)... 6 Manual II Control Panel Instructions (U100H)... 7 Manual
I.F.U Re/Processing Reusable Medical Devices
I.F.U Re/Processing Reusable Medical Devices Distributed by: MANUFACTURER: GA 26-09-001 -EN /20130719 Contents 1 Overview of preparation methods... 3 2 Safety and responsibility... 4 3 Explanation of symbols...
Cavitator Ultrasonic Cleaner Instruction Manual Model 20G
Cavitator Ultrasonic Cleaner Instruction Manual Model 20G Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System
SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System This document contains Instructions for Use regarding the processing of the SterilContainer S prior to sterilization
Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator
Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79 Suzanne Latta, CSPDT Education Materials Coordinator This is an update of the ANSI/AAMI ST79 Comprehensive guide to
Recommendations for cleaning, decontamination and sterilisation. devices
Recommendations for cleaning, decontamination and sterilisation of MEDACTa INTERNATIONAL orthopedic devices 1 This document was prepared to provide cleaning, decontaminating and sterilising instructions
STERITITE INSTRUCTIONS FOR USE
STERITITE INSTRUCTIONS FOR USE If a rigid container system is used, the manufacturers instructions regarding set preparation and assembly should be followed. -ANSI/AAMI ST79: 2010 & A1:2010 Notes from
Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files
Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files Cautions Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine
Technical Data Monograph. Prolystica HP Enzymatic Automated Detergent Instrument Protection Properties (North America)
Technical Data Monograph Prolystica HP Enzymatic Automated Detergent Instrument Protection Properties (North America) Table of Contents 1. Introduction....3 2. Purpose...3 3. Methods...4 4. Results....5
Is Your Ultrasonic Cleaning System Living Up to Its Potential?
Is Your Ultrasonic Cleaning System Living Up to Its Potential? Some guidelines about ultrasonic cleaning equipment and performance. The use of ultrasonic cleaning equipment to clean or degrease parts has
Call our hotline at for all your instrument care and detergent questions. Medline Super Concentrates
Everybody Cares About Instrument Care Surgeons, O.R. staff and C.S. workers agree that proper instrument care makes sense. Besides prolonging the life of a costly investment, regular maintenance results
Technical Data Monograph. The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products
Technical Data Monograph The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products Table of Contents ground...1 Purpose...1 Methods...1 Results...1 Conclusion...5
5.7 L ULTRASONIC CLEANING SYSTEM. BioSonic UC150
5.7 L ULTRASONIC CLEANING SYSTEM BioSonic UC150 2017 TRUSTED BRAND Three Decades of Trusted Technology BioSonic UC150 BioSonic UC125 BioSonic UC50DB BioSonic UC95 BioSonic UC300 Designed for the dental
INTRODUCTION UNPACKING & IMPORTANT 3-4 SAFETY INSTRUCTIONS SUGGESTED APPLICATIONS SONIC - D SERIES OPERATION INSTRUCTIONS 7-8 SONIC - MX SERIES 10-11
SONIC D USER GUIDE INTRODUCTION UNPACKING & IMPORTANT SAFETY INSTRUCTIONS SUGGESTED APPLICATIONS SONIC - D SERIES OPERATION INSTRUCTIONS SONIC - MX SERIES OPERATION INSTRUCTIONS DIFFERENT CLEANING METHODS
Whittemore Ultrasonic Cleaner
Whittemore Ultrasonic Cleaner Tank Capacity Heating Power Ultrasonic Power Time Setting Temperature Setting 1.3L 50W 60W 1-30 minutes 0-80 degrees Celsius 2L 50W 60W 1-30 minutes 0-80 degrees Celsius 6L
Cavitator Ultrasonic Cleaners
Cavitator Ultrasonic Cleaners Instruction Manual 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com email:
WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS
WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS Always with you Contents Introduction 3 Levels of cleanliness 5 Cleaning and disinfection processes 6 Washer-disinfector for human-waste containers
Processing instructions for the Ligamys suture forceps
Processing instructions for the Ligamys suture forceps Table of contents 1 Scope of application 4 2 Warnings and precautions 4 5 3 Restrictions 6 4 Processing instructions 7 4.1 Processing immediately
Cleaning Verification
Cleaning Verification Connecticut Central Service Association President IAHCSMM chapter 6 years!! AAMI STWG40 (ST79) voting member IAHCSMM ORTHO COUNCIL IAHCSMM Executive Board Member President David Jagrosse
Precision Ultrasonic Cleaning Equipment Buyers Guide
Precision Ultrasonic Cleaning Equipment Buyers Guide Contents Introduction... 3 Size... 3 Tank Specification... 3 Control... 4 Transducer Efficiency... 4 Ultrasonic Power... 4 Timer... 5 Basket... 5 Lid...
StatClean - Ultrasonic Cleaner
StatClean - Ultrasonic Cleaner USER MANUAL FEATURES: Large Tank Capacity Large Tank Capacity Control panel with capacitive sensing technology Drainage valve Tank capacity 6.0 L / 1.6 gallon. Tank size:
Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files
Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files Cautions Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine
Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches
Caution Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine content.
Infection Prevention and Control N/A. Executive Director of Nursing and Quality, DIPC. IPC Governance Meeting Members
Document Details Title Trust Ref No 1114-41724 Local Ref (optional) Main points the document covers Who is the document aimed at? Author Approval process Approved by (Committee/Director) Approval Date
Cleaning and Sterilization for Instruments & Posts
Cleaning and Sterilization for Instruments & Posts EN FOR DENTAL USE ONLY CLEANING AND STERILIZATION PROCEDURE FOR ENDODONTIC FILES, HAND INSTRUMENTS, PINS AND POSTS, STAINLESS STEEL DRILLS, STAINLESS
Clean Smarter. Systems Catalog
Clean Smarter Systems Catalog From the President Ultra Clean Systems strives to offer you the most robust, versatile, timesaving, and energy-efficient ultrasonic cleaning systems in the medical industry.
Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices
Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices 71381339 REVA CLEANING AND STERILIZATION BRO.indd 1 5/21/12 3:41 PM 71381339 REVA CLEANING AND STERILIZATION
OPERATIONAL & INSTRUCTION MANUAL. Models: 1000M, 1300M, 2000M and 2100M. (120v) UltraSonic LLC. P.O. Box Cincinnati, Ohio 45255
OPERATIONAL & INSTRUCTION MANUAL Models: 1000M, 1300M, 2000M and 2100M (120v) UltraSonic LLC P.O. Box 54081 Cincinnati, Ohio 45255 Tel: 513-502-9746 Fax: 513-702-2399 info@ultrasonicllc.com www.ultrasonicllc.com
FLASH PAK STERILIZATION CONTAINER SYSTEM
INSTRUCTIONS FOR USE FLASH PAK STERILIZATION CONTAINER SYSTEM Description The Flash Pak Sterilization Container System consists of a family of rigid reusable containers that provide an effective sterilization
Turbo Sonic Raytech. Ultrasonic Cleaner. Operating Instructions
SPECIFICATIONS Description Digital Ultrasonic Cleaner Model TS-6000 Item No. (115V) 7631725 (230V) 7631726 Tank Size 12.7 x 8.0 x 3.9 in. 32.3 x 20.3 x 9.9 cm Longest item that can fit in tank 13.4 / 34.0
STERIS Instrument Cleaning Chemistries
STERIS is REACH Compliant. What is REACH? REACH is a European Union regulation concerning the Registration, Evaluation, Authorisation and restriction of Chemicals. It came into force on 1st June 2007 and
www.endgermsnow.com 1-855-220-0540 Evergreen Cleaning & Sanitizing Solutions Inc. in association with Glissen Chemical Company Inc. presents: The Green Alternative Biodegradable No toxic ingredients Cosmetic
Is my water safe to drink? How do I determine the quality of my water? Common Questions about Discolored Water: Cloudy or milky water
Is my water safe to drink? The word, "safe" is a relative term that must be considered based on each individual's health and overall well-being. Since drinking water comes from sources that include: rivers,
Application Data Sheet
Application Data Sheet Chemical Cleaning after Thinning, Backside Grinding, Lapping, or Polishing of Silicon or Gallium Nitride Substrates Wafer cleaning after thinning, backside grinding, polishing, or
Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more. NEW generation instrument cleaners
Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more NEW generation instrument cleaners Now you can achieve a new level of automated cleaning Instrument Cleaning Chemistries Instruments
This document contains the following information.
Page1 This document contains the following information. Pg 1 3: General information on BIOWASHBALL Pg 3 6: Frequently Asked Questions Pg 6 7: TEST - Laundry water - BIOWASHBALL versus Detergent Pg 8 10:
Residential Application
Residential Application Technical Data Sheet Matrix Polyacryl Network Appearance Small light yellow/beige balls Surface Ceramic Template Surface Moisture Content 24 to 28% Density 1,18 to 1,22 Weight 650g/L
Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector
Technical Data Monograph Reliance Vision Single Chamber Washer/Disinfector Table of Contents 1. Introducing: the Reliance Vision Single Chamber Washer/Disinfector...3 2. Environmentally Conscious Design...3
Cleaning systems Overview
. Cleaning systems Cleaning systems Overview 424 Ultrasonic cleaning units 434 Cleaning products for ultrasonic cleaners 422 Tel. +49 (0) 22 04 / 8 39-0 Fax +49 (0) 22 04 / 8 39-1 info@joke.de . Cleaning
Lower Your Costs. Expand Your Flexibility.
Washing Systems Lower Your Costs. Expand Your Flexibility. Reliance Synergy Washer/Disinfector The Value of Synergy With the Reliance Synergy Washer/Disinfector, STERIS introduces washing systems technologies
SHARPER IMAGE. Professional Electrostatic Air Purifier with Permanent Stainless Steel Filter Model: and USE AND CARE GUIDE
SHARPER IMAGE Professional Electrostatic Air Purifier with Permanent Stainless Steel Filter Model: 203833-01 and 203833-02 USE AND CARE GUIDE TABLE OF CONTENTS About Your Sharper Image Ionic Comfort...
MANUAL CLEANING IS A VERY IMPORTANT PART OF THE
CRCST Self-Study Lesson Plan Lesson No. CRCST 160 (Technical Continuing Education - TCE) Sponsored by: by Robert Glover, AS, CRCST, CIS Sterile Processing Aide Riverside Hospital, Va. Manual Cleaning LEARNING
Dr. Weigert - New Standards in Cleaning and Disinfection of Medical Devices
Mongolian Symposium 14-15 September 2016, Ulaanbaatar Dr. Weigert - New Standards in Cleaning and Disinfection of Medical Devices Michael Kacherai Chemische Fabrik Dr. Weigert Hamburg 1 Dr. Weigert Company
EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd
EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE ALKAPHARM UK Ltd June 2008 HOSPITAL INFECTION RESEARCH LABORATORY CITY HOSPITAL DUDLEY ROAD BIRMINGHAM B18 7QH SUPPLIER/MANUFACTURER Alkapharm UK Ltd
User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use
Electric Kettle Model MJ-EK5AEU (UK) Household Use User s Manual Thank you for your purchase. Please read this User s Manual before using this product. Retain this User s Manual for future reference. Contents
Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning
Presenter: Malcolm McLaughlin Date: 04/04/2019 A Review of Medical Device and Optical Critical Cleaning Introduction Malcolm McLaughlin VP, Product & Business Development 30+ years detergent formulation,
INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS
INSTRUCTIONS FOR USE & STERILIZATION PMS PRECISION MEDICAL SPECIALITIES GMBH Kreuzstrasse 5 DE-78532 Tuttlingen PO Box 4607 DE-78511 Tuttlingen Fon: +49 74 61 13 131 Fax: +49 74 61 76 698 info@pms-tuttlingen.de
Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental
IC9: 0600 LAUNDRY 1.0 STANDARD All staff must follow Routine Practices when handling soiled Off site processing (general linen) Off site processing (general linen) will not require special separation of
PARTS CLEANING AND DEGREASING
Important Note: The following text is excerpted directly from the New York State Department of Environmental Conservation s publication, Environmental Compliance, Pollution Prevention, and Self Assessment
U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information
Health Information U S E R G U I D E Home Respiratory Equipment Cleaning Guide This document is intended for Patients and Families for use at home The goal of the cleaning guide is to properly handle,
Clean Smarter. Systems Catalog
Clean Smarter Systems Catalog From the President Ultra Clean Systems strives to offer you the most robust, versatile, timesaving, and energy-efficient ultrasonic cleaning systems in the medical industry.