THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

Size: px
Start display at page:

Download "THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION"

Transcription

1 CFSA CSSD Conference Durban ICC Wednesday 8 th March 2017 Using technology to improve patient safety THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION Helen Loudon Independent Infection Prevention Practitioner Helen Loudon Risk Management Nurse Specialist

2 Treat your investment with care and respect Used surgical instruments are like dirty dishes the longer they dry out in the sink, the harder they are to clean! Cleaning is the single most important step in making a medical device safe and ready for reuse Ultrasonic cleaning is considered to be far superior and more reliable than manual cleaning If undertaken correctly, 99.9% soil will be removed in 3-5 minutes 2

3 Safety challenges Instruments and minimally invasive equipment is becoming more complex Equipment is a huge capital investment Microbial biofilm and organic soil are resistant to manual removal Deadly pathogens are then spread through indirect contact transmission via hard to reach surfaces, lumens and crevices Pressured turn around times! 3

4 Bioburden on equipment surfaces under high magnification 4

5 How do ultrasonic cleaners work? Ultrasonic cleaners comprise 3 main parts: transducer = a device which converts one form of energy into another (eg. electricity to sonic waves ) ultrasonic generator cleaning tank Ultrasonic cleaning works through cavitation. The high intensity sound waves make tiny bubbles on the surfaces of the instruments. These bubbles expand until they become unstable and collapse or implode. These shock waves physically loosen and remove micro-organisms and other adherent debris from even the most inaccessible surfaces of a soiled instrument 5

6 Types of instruments which should undergo ultrasonic cleaning Ultrasonic-Cleaning

7 Important factors which affect ultrasonic cleaning Higher powered (Ie. wattage) machines will produce faster cleaning results The frequency of the sound waves will affect the effectiveness of the cavitation force The temperature, viscosity, density, vapor pressure and surface tension of the cleaning solution are critical to the effectiveness of ultrasonic cleaning Machines with lower frequency (sound waves) machines may be noisier - BUT, higher frequency sound waves will produce weaker cavitation (the collapsing power of each bubble) and the risk of less effective cleaning So BIGGER is not always BETTER seek advice on ultrasonic cleaners best suited to the type of equipment you need to clean 7

8 The cleaning solution A critically important and often neglected aspect! ph neutral (eg ) enzymatic detergent Low foaming Biodegradable safe to discard to sewer HIGH surface tension Ability to hold organic debris in solution NB! Gross debris should be rinsed off beforehand Do NOT let blood/fluids dry on instrumentation Change the water in the U/S cleaner frequently Run the U/S cleaner for 5-10 minutes to degas the water (to remove dissolved oxygen) before adding instruments 8

9 Good practice for ultrasonic cleaning Follow the equipment manufacturer s recommendations for the safest cleaning method Use the detergent solution recommended by the U/S bath manufacturer Keep used instrumentation moist until cleaned (Eg. with enzymatic cleaners or sterile pour H 2 O) Remove gross soiling with manual cleaning beforehand Use a mesh tray and don t exceed the recommended equipment capacity Ensure box locks, hinges and ratchets are open during soaking and cleaning Flush the air out of lumens with the cleaning solution Cover the tank in use to prevent aerosols and reduce noise 9

10 WARNINGS Blood, body fluids and normal saline are highly corrosive and will rust and pit instruments Quartz, silicon, plastic, carbon steel, gold or chromium plated instruments, endoscopic lenses and powered instruments should not be cleaned ultrasonically Do NOT place instruments directly onto the floor of the tank this will interfere with the production of sound waves and cause friction damage to the equipment Do NOT stack, fail to open/dismantle instruments or overload the tank 10

11 The impact of water quality A water quality assessment (by local municipality) should be undertaken periodically and after major maintenance to the water supply Excessively hard water will spot or stain instruments and the chlorine in tap water will cause pitting of instrument surfaces. Final rinsing should be undertaken with treated (de-ionized) water. De-ionized water removes soil and detergent residues more efficiently De-ionizing water removes dissolved minerals, iron and particles which could harm instruments. Adding water softeners removes calcium and magnesium ions which cause spotting on instruments. 11

12 Pre-purchasing questions 3 1. What are the dimensions of the ultrasonic cleaner? Is the size of its processing tank sufficient to accommodate the facility's soiled instruments? 2. How much power does the ultrasonic cleaner produce? Does the cleaner feature one power setting, or it is equipped with different power settings to process lightly soiled, heavily-soiled instruments, and delicate instruments? 3. What is the ultrasonic cleaner's frequency setting? Can it be adjusted? 4. What is the ultrasonic cleaner's standard cleaning time? Can this time be adjusted to permit extended cleaning for big loads and heavily-soiled instruments? 5. Does the manufacturer have any data to support its cleaning effectiveness? 6. Is the ultrasonic cleaner indicated for only a few types of instruments? What types of instruments, if any, are contraindicated? 12

13 Thank you! C mon, make my day wash your hands!

14 1. Ultrasonic cleaning effect on surgical instruments (30 secs) 2. Testing your ultrasonic cleaner the foil test (2 mins)

15 References and resources 1. CSSD Forum of South Africa Standard Operating Procedures Manual. SOP No. 32 Prepare, Load and Operate Ultrasonic Cleaner; SOP No. 33 Validating an Ultrasonic Cleaner 2. Shelnutt T. Ultrasonic Cleaners. Infection Control Today. September Muscarella L.F. The Benefits of Ultrasonic Cleaning. Infection Control Today. May The Association of Peri-operative Nurses. Recommended Practices for the Care and Cleaning of Surgical Instruments and Powered Equipment. AORN Journal 1997, Volume 65, Issue 1, Pages Kaiser H. McDonnell G. et al. Water quality and Reprocessing Instruments. Infection Control Today. May Instrument Reprocessing Working Group (10 th Edition). Reprocessing of instruments to retain value. 7. SAFMED Newsletter April Ultrasonic Cleaning. 15

When you sterilize an instrument set, you know what the standards are.

When you sterilize an instrument set, you know what the standards are. Sterilization & Infection Control The importance of cleaning in earnest A regular column on sterilization and infection control issues. When you sterilize an instrument set, you know what the standards

More information

THE BASICS OF DECONTAMINATION

THE BASICS OF DECONTAMINATION THE BASICS OF DECONTAMINATION Objectives Review the basic factors that impact cleaning and decontamination of surgical devices Present the fundamentals of manual and automatic cleaning Review various cleaning

More information

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS CAUTION: The following instructions are for all Sklar Coated stainless steel instruments. Read instructions prior to use. Improper

More information

2015 Myco Industries, Inc Fax:

2015 Myco Industries, Inc Fax: Endoscope Cleaning and Handling It is highly important that you manually clean the endoscope immediately after it is removed from the patient, BEFORE it is automated or manually disinfected. Cleaning your

More information

CLEANING INSTRUCTIONS

CLEANING INSTRUCTIONS Reusable Instrument Care Manual Pagoda Pedicle Screw System Manufacturer Ortho Development Corporation 12187 South Business Park Drive Draper, UT 84020 Phone 801-553-9991 Fax 801-553-9993 www.orthodevelopment.com

More information

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15 Recommended Care, Cleaning and Sterilization Instructions for Reusable Instruments & Accessories Symmetry Surgical Inc. 3034 Owen Drive, Antioch, TN 37013 USA 1-800-251-3000 Fax: 1-615-964-5566 www.symmetrysurgical.com

More information

ULTRASONIC (SONIC) CLEANING ENHANCES THE INSTRUMENT

ULTRASONIC (SONIC) CLEANING ENHANCES THE INSTRUMENT CRCST Self-Study Lesson Plan Lesson No. CRCST 153 (Technical Continuing Education - TCE) Sponsored by: by Ava Griffin, BSN, RN, CNOR CSP Educator University of Chicago and Patti Koncur IAHCSMM Education

More information

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK Irrespective of where the decontamination is performed or who it is performed by the

More information

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray Equipment Cleaning and Sterilization Table of Contents 1. WARNINGS AND PRECAUTIONS... 3 2. INSTRUMENT PREPARATION... 3 3. CAVITY PREPARATION

More information

BioSonic Ultrasonic Cleaning Systems. biosonic.coltene.com

BioSonic Ultrasonic Cleaning Systems. biosonic.coltene.com BioSonic Ultrasonic Cleaning Systems biosonic.coltene.com 2018 BioSonic An essential part of your Infection Control System Three Decades of Trusted Technology BioSonic UC150 BioSonic UC125 BioSonic UC50DB

More information

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE Tested for optimal cleaning and performance ciso 15883 VALIDATED 2 GETINGE CLEAN GETINGE CLEAN THE ANSWER TO YOUR CLEANING PROBLEMS What does the word

More information

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization 1. WARNINGS AND PRECAUTIONS 1.1. Caution should be exercised when handling instruments with sharp points, or cutting/drilling

More information

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية 1. POLICY STATEMENT: Cleaning, decontamination and sterilization method should be done in CSSD service facility not in the end user department side. 2. PURPOSE: To ensure the proper way of collections,

More information

The Principles, The Process, and The Results:

The Principles, The Process, and The Results: The Principles, The Process, and The Results: Presented by: Fred Alston, CSPDT Eastern Region Clinical Sales and Support Manager April 21, 2017 I am an employee of Healthmark Industries Fraser, Michigan

More information

Instructions for Use Spinal Punches IFU

Instructions for Use Spinal Punches IFU Indications for use Spinal punches are manually operated instruments indicated for cutting or biting bone during surgery involving the skull or spinal column. Contraindiciations Instruments should not

More information

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization 1. WARNINGS AND PRECAUTIONS 1.1. Caution should be exercised when handling instruments with sharp points, or cutting/drilling

More information

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L 1 2 Ideal for cleaning surgical, medical, dental instruments and equipment. Available in various sizes. Before placing instruments into the Ultrasonic Cleaner a degas cycle should be run. Then a clinical

More information

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS CLEANING AND HANDLING OF WRIGHT INSTRUMENTS 150824-0 The following languages are included in this packet: English (en) Deutsch (de) Nederlands (nl) Français (fr) Español (es) Italiano (it) Português (pt)

More information

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY SUBJECT: ULTRASONIC CLEANER MONITORING DAILY DEPARTMENT: CPD, CSSD, SPA, MDRD, SPD, dental offices, medical offices and department using

More information

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing Instructions for Use. Description and Intended Use Integra LifeSciences Corporation reusable surgical device sets consist of various

More information

PERFORM Operating Document

PERFORM Operating Document PERFORM Operating Document Use and Maintenance of Tuttnauer Table-Top Autoclave PC-POD-CA-006-v03 Revision History Version Reason for Revision Date 01 New POD 13-Aug-13 02 POD Section 3.1.3 and 3.2 revised

More information

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY Sonic Irrigator SA Automated Cannulated Instrument Reprocessing Sonic Irrigation Twin Cannulated Pulse Flush Systems Load performance optimisation Independent process monitoring EN ISO 15883/HTM 2030 compliant

More information

Surgical Instrument Cleaning Process

Surgical Instrument Cleaning Process Surgical Instrument Cleaning Process The Universal Processing Solution The Surgical Instrument Enzyme Detergent Lubricant Cleaners The Surgical Instrument Detergent Enzyme Lubricant Cleaner will cut costs.

More information

Aesculap Implant Systems

Aesculap Implant Systems Aesculap Implant Systems Aesculap Implant Systems Orthopedics USA Instructions for Use/Technical Description Page 1 of 14 Symbols on product packages Caution, general warning symbol Caution, see documentation

More information

Aesculap Implant Systems

Aesculap Implant Systems Aesculap Implant Systems Aesculap Implant Systems Orthopedics USA Instructions for Use/Technical Description Page 1 of 16 Symbols on product packages! Caution, general warning symbol Caution, see documentation

More information

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY natoli.com PROPER TOOL CLEANING IS CRUCIAL EXTEND TOOL LIFE DECREASE PRESS DOWNTIME REDUCE PRODUCTION-RELATED COSTS IMPROVE TABLET QUALITY Tablet

More information

Cleaning & Sterilization

Cleaning & Sterilization Handpieces & Attachments Instruments Cleaning & Sterilization System 7 System 6 System 5 CD4 CD3 SABO 2 SABO RemB CORE TPS Processing Instructions User/Patient Safety all contribute to the efficacy of

More information

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories Table of Contents 1. Intended Use Statement... 3 2. Proper Use... 3 3. General Information...

More information

Before digging into the 10 things you should know let s start with a brief explanation of the process.

Before digging into the 10 things you should know let s start with a brief explanation of the process. Ultrasonic cleaners are unsurpassed when it comes to removing contaminants from virtually any hard surface that can be safely immersed in a cleaning solution. The challenge is selecting the correct ultrasonic

More information

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS) INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS) 1 INTRODUCTION This paper is intended to give general

More information

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

IMPORTANT INFORMATION ON THE DEPUY SYNTHES For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE DEPUY SYNTHES MatrixNEURO RECONSTRUCTION MESH, STERILE MatrixNEURO PREFORMED MESH, STERILE GP2949-B-CAN DESCRIPTION The DePuy Synthes

More information

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE THEATRE AND STERILE PROCEDURES WALLS/TILES - Wash all surfaces from top to bottom using F10CLXD, rinse with - Wash off visible dirt (e.g. blood) using F10CLXD CHAIRS - Trigger spray using F10CL and wipe

More information

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904) Fiber Optic Cables Instructions for Use and Processing Instructions DFU-950-0031-00 Fiber Optic Cables Made in USA Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904) 737 7611

More information

RECOMMENDATIONS FOR CLEANING DEVICES

RECOMMENDATIONS FOR CLEANING DEVICES RECOMMENDATIONS FOR CLEANING D E C O N TA M I N AT I O N A N D S T E R I L I Z AT I O N O F M E D A C T A I N T E R N A T I O N A L O R T H O P E D I C DEVICES 1 This document was prepared to provide cleaning,

More information

Sterile Processing. Knowledge, Skills, Competencies. Terri Goodman, PhD, RN

Sterile Processing. Knowledge, Skills, Competencies. Terri Goodman, PhD, RN Sterile Processing Knowledge, Skills, Competencies Terri Goodman, PhD, RN This publication is intended to be a helpful information resource, and reflects the expert advice and views of the author. It is

More information

Instrument Cleaning Chemistries Automated Washing Process

Instrument Cleaning Chemistries Automated Washing Process Instrument Cleaning Chemistries Automated Washing Process Procedure Pre-cleaning Prolystica Enzymatic Presoak and Cleaner Klenzyme Enzymatic Presoak and Cleaner ZolvStat Multi-Enzymatic Detergent Pre-Klenz

More information

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS GENERAL - BEST PRACTICE CLEANING EQUIPMENT Sweep or rinse away loose debris. On floors, use a dust-attracting mop, not a broom Where possible, make use of vacuum (Clean bag daily) Remove spills (feaces,

More information

Cavitator Ultrasonic Cleaners

Cavitator Ultrasonic Cleaners Cavitator Ultrasonic Cleaners Instruction Manual (for model # 18G) 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com

More information

DEVICES THAT HAVE NOT BEEN ADEQUATELY CLEANED CANNOT

DEVICES THAT HAVE NOT BEEN ADEQUATELY CLEANED CANNOT Lesson No. CIS 244 (Instrument Continuing Education - ICE) Sponsored by: by Donna Swenson, BS, CRCST, CHL, CSPDM Clinical Operations Manager Synergy Health PLC, Tampa, FL DECONTAMINATION LEARNING OBJECTIVES

More information

Operating / User Manual

Operating / User Manual UniARM Surgical Support System Operating / User Manual Version 1.1 MITAKA KOHKI Co., Ltd. 1. Introduction Introduction Thank you for purchasing the UniARM for use in surgical procedures. To use the device

More information

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS GENERAL - BEST PRACTICE CLEANING EQUIPMENT Sweep or rinse away loose debris. On floors, use a dust-attracting mop, preferably not a broom Where possible, make use of vacuum (Clean bag daily) Remove spills

More information

Decontamination. CIS Self-Study Lesson Plan Lesson No. CIS 244 (Instrument Continuing Education - ICE)

Decontamination. CIS Self-Study Lesson Plan Lesson No. CIS 244 (Instrument Continuing Education - ICE) Lesson No. CIS 244 (Instrument Continuing Education - ICE) Sponsored by: by Donna Swenson, BS, CRCST, CHL, CSPDM Clinical Operations Manager Synergy Health PLC, Tampa, FL Decontamination Learning Objectives

More information

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE THEATRE AND STERILE PROCEDURES WALLS/TILES - Wash all surfaces from top to bottom using F10SCXD, rinse with - Wash off visible dirt (e.g. blood) using F10SCXD CHAIRS - Trigger spray using F10SC and wipe

More information

CLEANING OF INSTRUMENTS

CLEANING OF INSTRUMENTS Disclaimer: This article is provided to Keir Surgical Ltd. by SPS Medical. The information in this document should be used in conjunction with your hospital or institution s cleaning and decontamination

More information

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd   Ph: Fax: INSTRUCTION MANUAL Laboratory Equipment Pty Ltd email: sales@labec.com.au Ph: 02 9560 2811 Fax: 02 9560 6131 www.labec.com.au 2014 FXP16M LABORATORY EQUIPMENT PTY LTD 26 30 Farr St, Marrickville, NSW 2204

More information

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012 Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods 11.40-12.30 27 th July 2012 Chirurgie-Instrumenten-Arbeitsgruppe Berlin Dr. med. Dipl.-Ing. Thomas W. Fengler What is so manual

More information

Cavitator Ultrasonic Cleaner Instruction Manual

Cavitator Ultrasonic Cleaner Instruction Manual Cavitator Ultrasonic Cleaner Instruction Manual Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com

More information

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES Contents: Pagina 1 Introduction...2 2 Treatment instructions...2 3 Cleaning...2 3.1 Place of use...4

More information

Contents. Ultrawave baths are manufactured in the UK and conform to exacting international standards.

Contents. Ultrawave baths are manufactured in the UK and conform to exacting international standards. Contents Contents... 1 Safety Instructions... 1 Installation... 3 Quick Guide... 4 Manual I Control Panel Instructions (U50, U95, U100, U300)... 6 Manual II Control Panel Instructions (U100H)... 7 Manual

More information

I.F.U Re/Processing Reusable Medical Devices

I.F.U Re/Processing Reusable Medical Devices I.F.U Re/Processing Reusable Medical Devices Distributed by: MANUFACTURER: GA 26-09-001 -EN /20130719 Contents 1 Overview of preparation methods... 3 2 Safety and responsibility... 4 3 Explanation of symbols...

More information

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G Cavitator Ultrasonic Cleaner Instruction Manual Model 20G Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com

More information

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System This document contains Instructions for Use regarding the processing of the SterilContainer S prior to sterilization

More information

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79 Suzanne Latta, CSPDT Education Materials Coordinator This is an update of the ANSI/AAMI ST79 Comprehensive guide to

More information

Recommendations for cleaning, decontamination and sterilisation. devices

Recommendations for cleaning, decontamination and sterilisation. devices Recommendations for cleaning, decontamination and sterilisation of MEDACTa INTERNATIONAL orthopedic devices 1 This document was prepared to provide cleaning, decontaminating and sterilising instructions

More information

STERITITE INSTRUCTIONS FOR USE

STERITITE INSTRUCTIONS FOR USE STERITITE INSTRUCTIONS FOR USE If a rigid container system is used, the manufacturers instructions regarding set preparation and assembly should be followed. -ANSI/AAMI ST79: 2010 & A1:2010 Notes from

More information

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files Cautions Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine

More information

Technical Data Monograph. Prolystica HP Enzymatic Automated Detergent Instrument Protection Properties (North America)

Technical Data Monograph. Prolystica HP Enzymatic Automated Detergent Instrument Protection Properties (North America) Technical Data Monograph Prolystica HP Enzymatic Automated Detergent Instrument Protection Properties (North America) Table of Contents 1. Introduction....3 2. Purpose...3 3. Methods...4 4. Results....5

More information

Is Your Ultrasonic Cleaning System Living Up to Its Potential?

Is Your Ultrasonic Cleaning System Living Up to Its Potential? Is Your Ultrasonic Cleaning System Living Up to Its Potential? Some guidelines about ultrasonic cleaning equipment and performance. The use of ultrasonic cleaning equipment to clean or degrease parts has

More information

Call our hotline at for all your instrument care and detergent questions. Medline Super Concentrates

Call our hotline at for all your instrument care and detergent questions. Medline Super Concentrates Everybody Cares About Instrument Care Surgeons, O.R. staff and C.S. workers agree that proper instrument care makes sense. Besides prolonging the life of a costly investment, regular maintenance results

More information

Technical Data Monograph. The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products

Technical Data Monograph. The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products Technical Data Monograph The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products Table of Contents ground...1 Purpose...1 Methods...1 Results...1 Conclusion...5

More information

5.7 L ULTRASONIC CLEANING SYSTEM. BioSonic UC150

5.7 L ULTRASONIC CLEANING SYSTEM. BioSonic UC150 5.7 L ULTRASONIC CLEANING SYSTEM BioSonic UC150 2017 TRUSTED BRAND Three Decades of Trusted Technology BioSonic UC150 BioSonic UC125 BioSonic UC50DB BioSonic UC95 BioSonic UC300 Designed for the dental

More information

INTRODUCTION UNPACKING & IMPORTANT 3-4 SAFETY INSTRUCTIONS SUGGESTED APPLICATIONS SONIC - D SERIES OPERATION INSTRUCTIONS 7-8 SONIC - MX SERIES 10-11

INTRODUCTION UNPACKING & IMPORTANT 3-4 SAFETY INSTRUCTIONS SUGGESTED APPLICATIONS SONIC - D SERIES OPERATION INSTRUCTIONS 7-8 SONIC - MX SERIES 10-11 SONIC D USER GUIDE INTRODUCTION UNPACKING & IMPORTANT SAFETY INSTRUCTIONS SUGGESTED APPLICATIONS SONIC - D SERIES OPERATION INSTRUCTIONS SONIC - MX SERIES OPERATION INSTRUCTIONS DIFFERENT CLEANING METHODS

More information

Whittemore Ultrasonic Cleaner

Whittemore Ultrasonic Cleaner Whittemore Ultrasonic Cleaner Tank Capacity Heating Power Ultrasonic Power Time Setting Temperature Setting 1.3L 50W 60W 1-30 minutes 0-80 degrees Celsius 2L 50W 60W 1-30 minutes 0-80 degrees Celsius 6L

More information

Cavitator Ultrasonic Cleaners

Cavitator Ultrasonic Cleaners Cavitator Ultrasonic Cleaners Instruction Manual 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com email:

More information

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS Always with you Contents Introduction 3 Levels of cleanliness 5 Cleaning and disinfection processes 6 Washer-disinfector for human-waste containers

More information

Processing instructions for the Ligamys suture forceps

Processing instructions for the Ligamys suture forceps Processing instructions for the Ligamys suture forceps Table of contents 1 Scope of application 4 2 Warnings and precautions 4 5 3 Restrictions 6 4 Processing instructions 7 4.1 Processing immediately

More information

Cleaning Verification

Cleaning Verification Cleaning Verification Connecticut Central Service Association President IAHCSMM chapter 6 years!! AAMI STWG40 (ST79) voting member IAHCSMM ORTHO COUNCIL IAHCSMM Executive Board Member President David Jagrosse

More information

Precision Ultrasonic Cleaning Equipment Buyers Guide

Precision Ultrasonic Cleaning Equipment Buyers Guide Precision Ultrasonic Cleaning Equipment Buyers Guide Contents Introduction... 3 Size... 3 Tank Specification... 3 Control... 4 Transducer Efficiency... 4 Ultrasonic Power... 4 Timer... 5 Basket... 5 Lid...

More information

StatClean - Ultrasonic Cleaner

StatClean - Ultrasonic Cleaner StatClean - Ultrasonic Cleaner USER MANUAL FEATURES: Large Tank Capacity Large Tank Capacity Control panel with capacitive sensing technology Drainage valve Tank capacity 6.0 L / 1.6 gallon. Tank size:

More information

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files Cautions Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine

More information

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches Caution Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine content.

More information

Infection Prevention and Control N/A. Executive Director of Nursing and Quality, DIPC. IPC Governance Meeting Members

Infection Prevention and Control N/A. Executive Director of Nursing and Quality, DIPC. IPC Governance Meeting Members Document Details Title Trust Ref No 1114-41724 Local Ref (optional) Main points the document covers Who is the document aimed at? Author Approval process Approved by (Committee/Director) Approval Date

More information

Cleaning and Sterilization for Instruments & Posts

Cleaning and Sterilization for Instruments & Posts Cleaning and Sterilization for Instruments & Posts EN FOR DENTAL USE ONLY CLEANING AND STERILIZATION PROCEDURE FOR ENDODONTIC FILES, HAND INSTRUMENTS, PINS AND POSTS, STAINLESS STEEL DRILLS, STAINLESS

More information

Clean Smarter. Systems Catalog

Clean Smarter. Systems Catalog Clean Smarter Systems Catalog From the President Ultra Clean Systems strives to offer you the most robust, versatile, timesaving, and energy-efficient ultrasonic cleaning systems in the medical industry.

More information

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices 71381339 REVA CLEANING AND STERILIZATION BRO.indd 1 5/21/12 3:41 PM 71381339 REVA CLEANING AND STERILIZATION

More information

OPERATIONAL & INSTRUCTION MANUAL. Models: 1000M, 1300M, 2000M and 2100M. (120v) UltraSonic LLC. P.O. Box Cincinnati, Ohio 45255

OPERATIONAL & INSTRUCTION MANUAL. Models: 1000M, 1300M, 2000M and 2100M. (120v) UltraSonic LLC. P.O. Box Cincinnati, Ohio 45255 OPERATIONAL & INSTRUCTION MANUAL Models: 1000M, 1300M, 2000M and 2100M (120v) UltraSonic LLC P.O. Box 54081 Cincinnati, Ohio 45255 Tel: 513-502-9746 Fax: 513-702-2399 info@ultrasonicllc.com www.ultrasonicllc.com

More information

FLASH PAK STERILIZATION CONTAINER SYSTEM

FLASH PAK STERILIZATION CONTAINER SYSTEM INSTRUCTIONS FOR USE FLASH PAK STERILIZATION CONTAINER SYSTEM Description The Flash Pak Sterilization Container System consists of a family of rigid reusable containers that provide an effective sterilization

More information

Turbo Sonic Raytech. Ultrasonic Cleaner. Operating Instructions

Turbo Sonic Raytech. Ultrasonic Cleaner. Operating Instructions SPECIFICATIONS Description Digital Ultrasonic Cleaner Model TS-6000 Item No. (115V) 7631725 (230V) 7631726 Tank Size 12.7 x 8.0 x 3.9 in. 32.3 x 20.3 x 9.9 cm Longest item that can fit in tank 13.4 / 34.0

More information

STERIS Instrument Cleaning Chemistries

STERIS Instrument Cleaning Chemistries STERIS is REACH Compliant. What is REACH? REACH is a European Union regulation concerning the Registration, Evaluation, Authorisation and restriction of Chemicals. It came into force on 1st June 2007 and

More information

www.endgermsnow.com 1-855-220-0540 Evergreen Cleaning & Sanitizing Solutions Inc. in association with Glissen Chemical Company Inc. presents: The Green Alternative Biodegradable No toxic ingredients Cosmetic

More information

Is my water safe to drink? How do I determine the quality of my water? Common Questions about Discolored Water: Cloudy or milky water

Is my water safe to drink? How do I determine the quality of my water? Common Questions about Discolored Water: Cloudy or milky water Is my water safe to drink? The word, "safe" is a relative term that must be considered based on each individual's health and overall well-being. Since drinking water comes from sources that include: rivers,

More information

Application Data Sheet

Application Data Sheet Application Data Sheet Chemical Cleaning after Thinning, Backside Grinding, Lapping, or Polishing of Silicon or Gallium Nitride Substrates Wafer cleaning after thinning, backside grinding, polishing, or

More information

Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more. NEW generation instrument cleaners

Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more. NEW generation instrument cleaners Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more NEW generation instrument cleaners Now you can achieve a new level of automated cleaning Instrument Cleaning Chemistries Instruments

More information

This document contains the following information.

This document contains the following information. Page1 This document contains the following information. Pg 1 3: General information on BIOWASHBALL Pg 3 6: Frequently Asked Questions Pg 6 7: TEST - Laundry water - BIOWASHBALL versus Detergent Pg 8 10:

More information

Residential Application

Residential Application Residential Application Technical Data Sheet Matrix Polyacryl Network Appearance Small light yellow/beige balls Surface Ceramic Template Surface Moisture Content 24 to 28% Density 1,18 to 1,22 Weight 650g/L

More information

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector Technical Data Monograph Reliance Vision Single Chamber Washer/Disinfector Table of Contents 1. Introducing: the Reliance Vision Single Chamber Washer/Disinfector...3 2. Environmentally Conscious Design...3

More information

Cleaning systems Overview

Cleaning systems Overview . Cleaning systems Cleaning systems Overview 424 Ultrasonic cleaning units 434 Cleaning products for ultrasonic cleaners 422 Tel. +49 (0) 22 04 / 8 39-0 Fax +49 (0) 22 04 / 8 39-1 info@joke.de . Cleaning

More information

Lower Your Costs. Expand Your Flexibility.

Lower Your Costs. Expand Your Flexibility. Washing Systems Lower Your Costs. Expand Your Flexibility. Reliance Synergy Washer/Disinfector The Value of Synergy With the Reliance Synergy Washer/Disinfector, STERIS introduces washing systems technologies

More information

SHARPER IMAGE. Professional Electrostatic Air Purifier with Permanent Stainless Steel Filter Model: and USE AND CARE GUIDE

SHARPER IMAGE. Professional Electrostatic Air Purifier with Permanent Stainless Steel Filter Model: and USE AND CARE GUIDE SHARPER IMAGE Professional Electrostatic Air Purifier with Permanent Stainless Steel Filter Model: 203833-01 and 203833-02 USE AND CARE GUIDE TABLE OF CONTENTS About Your Sharper Image Ionic Comfort...

More information

MANUAL CLEANING IS A VERY IMPORTANT PART OF THE

MANUAL CLEANING IS A VERY IMPORTANT PART OF THE CRCST Self-Study Lesson Plan Lesson No. CRCST 160 (Technical Continuing Education - TCE) Sponsored by: by Robert Glover, AS, CRCST, CIS Sterile Processing Aide Riverside Hospital, Va. Manual Cleaning LEARNING

More information

Dr. Weigert - New Standards in Cleaning and Disinfection of Medical Devices

Dr. Weigert - New Standards in Cleaning and Disinfection of Medical Devices Mongolian Symposium 14-15 September 2016, Ulaanbaatar Dr. Weigert - New Standards in Cleaning and Disinfection of Medical Devices Michael Kacherai Chemische Fabrik Dr. Weigert Hamburg 1 Dr. Weigert Company

More information

EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd

EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE ALKAPHARM UK Ltd June 2008 HOSPITAL INFECTION RESEARCH LABORATORY CITY HOSPITAL DUDLEY ROAD BIRMINGHAM B18 7QH SUPPLIER/MANUFACTURER Alkapharm UK Ltd

More information

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use Electric Kettle Model MJ-EK5AEU (UK) Household Use User s Manual Thank you for your purchase. Please read this User s Manual before using this product. Retain this User s Manual for future reference. Contents

More information

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning Presenter: Malcolm McLaughlin Date: 04/04/2019 A Review of Medical Device and Optical Critical Cleaning Introduction Malcolm McLaughlin VP, Product & Business Development 30+ years detergent formulation,

More information

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS INSTRUCTIONS FOR USE & STERILIZATION PMS PRECISION MEDICAL SPECIALITIES GMBH Kreuzstrasse 5 DE-78532 Tuttlingen PO Box 4607 DE-78511 Tuttlingen Fon: +49 74 61 13 131 Fax: +49 74 61 76 698 info@pms-tuttlingen.de

More information

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental IC9: 0600 LAUNDRY 1.0 STANDARD All staff must follow Routine Practices when handling soiled Off site processing (general linen) Off site processing (general linen) will not require special separation of

More information

PARTS CLEANING AND DEGREASING

PARTS CLEANING AND DEGREASING Important Note: The following text is excerpted directly from the New York State Department of Environmental Conservation s publication, Environmental Compliance, Pollution Prevention, and Self Assessment

More information

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information Health Information U S E R G U I D E Home Respiratory Equipment Cleaning Guide This document is intended for Patients and Families for use at home The goal of the cleaning guide is to properly handle,

More information

Clean Smarter. Systems Catalog

Clean Smarter. Systems Catalog Clean Smarter Systems Catalog From the President Ultra Clean Systems strives to offer you the most robust, versatile, timesaving, and energy-efficient ultrasonic cleaning systems in the medical industry.

More information