INDEX INVERTER HYDRAULIC UNIT. Excluded from high-efficiency motor regulations. 7 MPa. 10 MPa. 16 MPa. 21 MPa. List of Hybrid Hydraulic Unit Models

Size: px
Start display at page:

Download "INDEX INVERTER HYDRAULIC UNIT. Excluded from high-efficiency motor regulations. 7 MPa. 10 MPa. 16 MPa. 21 MPa. List of Hybrid Hydraulic Unit Models"

Transcription

1 INDEX INVERTER HYDRAULIC UNIT Excluded from high-efficiency motor regulations List of Hybrid Hydraulic Unit Models P. to List of Super Unit Models Nomenclature P. Main Features and Functions Super Unit Hydraulic Circuits P.6 Features P. to Functions P.9 Function Option P.0 Hardware Option P. to Pressure Flow Rate Characteristics (Typical) P. to Specifications/External Dimension Diagram P. to Specifications/External Dimension Diagram P. to Specifications/External Dimension Diagram P.9 to Specifications/External Dimension Diagram P. to Operation Panel P.9 to 0 Electric Wiring P. to Options (Separately available parts) P. to Method of Selection P.9 Handling P.0 MPa 0 MPa 6 MPa MPa Oil Hydraulic Division Oil Hydraulic Equipment

2 Get more than energy savings!! Saving energy is essential. However, the Daikin hydraulic system goes one step further than conventional models. 0

3 Combining Daikin s original high-efficiency IPM motors and hydraulic technology enables an unparalleled energy-saving effect and advanced functions. Energy-saving technology that supports hybrid products Daikin was the first in the industry to introduce an interior permanent magnet synchronous motor (IPM motor) into air conditioners for household use. Daikin was also an early adopter in the industry of the IPM motor for use in industrial-use air conditioners. We have led the industry as a front runner in air conditioner energy-saving performance. Hybrid products equipped with variable speed motors, developed by making full use of Daikin s original energy-saving motor technology and its production capacity, help to achieve Powerful energy savings for factory equipment Double torque improves the energy-saving effect. Combining two rotational forces, magnetic torque generated by a powerful neodymium magnet and reluctance torque, generates more power with less electricity. Neodymium magnet Ferrite magnet Neodymium magnets provide more power substantially more than the ferrite magnets in general use. neodymium magnets, the key to this improved energy-saving effect! : A compound of neodymium (Nd, rare-earth element), iron (Fe), and boron (B). Neodymium magnets are known to have superior magnetic properties. : Rotational force generated by attractive force (reluctance = magnetic resistance) between iron and a magnet. Fundamental Principle of the IPM Motor With a rare-earth permanent magnet deeply embedded in the rotor, the IPM motor uses an electromagnetic structure that maximizes magnetic torque (attractive/repulsive force between the coil and permanent magnet) and reluctance torque (force of the coil that attracts iron). This structure achieves high torque and maximum efficiency while suppressing heat generation. Structure of the IPM motor Stator Structure of a conventional motor (AC servomotor) Iron Stator Rare-earth magnet IPM motor drive system (Interior permanent magnet synchronous motor) S N N S Rotor N [] Comparison of motor efficiency 0 The lengths of the magnetic field lines at the south and north poles are equivalent. Therefore, no reluctance torque that results in rotational force is generated. Daikin IPM motor Rated output (kw) 0 Daikin IPM motors are capable of outputting a large torque in low-speed ranges, eliminating the problems with insufficient torque in low-speed ranges often observed with general-purpose inverters General-purpose induction motor 0 General-purpose induction motor N (Surface permanent magnet synchronous motor: e.g., servomotor, brushless DC motor) N Torque (%) Motor efficiency (%) Daikin IPM motors have even greater efficiency than general-purpose induction motors and high-efficiency induction motors. High-efficiency induction motor S S [] Large torque at low speed 9 SPM motor N S Daikin IPM motor 00 6 Rotor Since the magnetic field lines at the south pole side are made longer than those at the north pole side, the magnetic field lines at the south pole will try to shorten like a stretched rubber band contracts, resulting in rotational force due to reluctance torque in the direction indicated by arrow. S Magnet Rotating magnetic field Rotation speed (min) 0

4 Specifications vary depending on the machine The Daikin product lineup provides various For machine tools discharge rate EcoRich EcoRich R Super EcoRich 0 L/min SUT00S00.0 kw See Pages to 0 L/min SUT00S00 SUT0S00.0 kw See Pages to L/min SUT00S0 SUT06S0.0 kw See Pages 9 to 0 0 L/min SUT00S00 SUT0S00. kw See Pages to L/min SUT00S0. L/min L/min EHU-L0 Equivalent to. kw EHU-M0 Equivalent to. kw EHU-L0. kw EHU-M0. kw EHUR- M0 Equivalent to. kw EHUS- M0R Equivalent to. kw. kw See Pages to 6 SUT0S0 L/min EHU-L0 Equivalent to 0. kw EHUR- M0 SUT00S0 SUT0S0 Equivalent to. kw. kw See Pages to 6 operating pressure MPa 6 MPa MPa MPa MPa MPa 6-pattern PQ control Idling stop Communication function Analog command input 0

5 type. functions and capacities according to the machine type. For general industrial machines Super Unit (high-performance type) discharge rate Super Unit (high-precision type) SUT00D0 P-SUT0DKW.0 kw See Pages to SUT00D0 00 L/min 0 L/min SUT00S00.0 kw SUT00S0 List of Hybrid Hydraulic Unit Models.0 kw See Pages to 6 SUT0D0 SUT6D0 L/min.0 kw SUT00S SUT00D SUT06D SUT0D 0 L/min SUT00S0.0 kw.0 kw See Pages to SUT00D06 SUT06D06 0 L/min.0 kw SUT00S0. kw See Pages to SUT00S0 SUT00S6 L/min SUT00S.0 kw SUT0S0 SUT06S6. kw See Pages to SUT00S0.0 kw See Pages 9 to SUT00S6.0 kw SUT0S0 SUT0S6. kw See Pages to 6. kw See Pages 9 to 0 MPa 6 MPa MPa operating pressure MPa MPa *: The above motor capacities are given for guidance only and do not represent the standard capacities of general motors. *: When selecting a Super Unit, verify the specifications of each model by referring to Pressure Flow rate Characteristics (Typical) on Pages and and How to Select a Super Unit on Page 9. For the purpose of making improvements, the specifications given in this catalog are subject to change without prior notice. Be sure to see the latest model chart. 0

6 List of Super Unit models Selecting the optimum model from a wide variety of Super Unit models Series Motor capacity operating pressure (MPa) flow rate (L/min) Tankless type Unit type Tank capacity (L) Page. kw. kw.0 SUT00S0-.0 SUT00S0- SUT0S0- SUT0S0- to 6. kw.0 SUT00S00- SUT0S00- to.0 kw.0 SUT00S0- SUT06S0-9 to 0 Single pump type.0 kw.0 kw.0 SUT00S00- SUT0S SUT00S00- to to. kw 0.0 SUT00S0- SUT0S0- to 6 Super Unit. kw. kw.0 kw 0.0 SUT00S0-6.0 SUT00S6-6.0 SUT00S6- SUT0S0- SUT0S6- SUT06S6- to 9 to. kw. SUT00D06- SUT06D06- to Double pump type.0 kw.0 kw 0.6 SUT00D- 0.6 SUT00D0- SUT06D- SUT0D- SUT0D0- SUT6D to to 6.0 kw 0.6 SUT00D0- P-SUT0DKW- 00 to Nomenclature. to.0 kw SUT a 0 b S c d 0 e f g h i a Model No. SUT: SUT series b Tank capacity 00: Tankless type 0: L 06: L 0: 00 L 6: L c Pump type D: Double pump type S: Single pump type d Pump discharge rate : L/min : L/min 0: 0 L/min : L/min 0: 0 L/min e operating pressure 0:.0 MPa 0: 0.0 MPa 6:., 6.0 MPa : 0.6 MPa f Design No. Incremented at model changes,... g Function Option C: With communication function (RSC) P: With analog input function h Hardware Option 0 Unit cover (except for L tank) 0 Controller cover (except for kw) 0 DCL (except for kw) 0 Separate power supplies for power system and control system 0 Water fill test compliant tank 06 Water leak test compliant tank 0 Level switch 0 Temperature switch 09 Thermometer 0 Micro separator Combination of to 0 above... i Non-standard No. N: Without control system A: With control system kw SUT a 00 b S c 0 d 0 e f g h a Model No. SUT: SUT series b Tank capacity 00: Tankless type c Pump type D: Double pump type S: Single pump type d Pump discharge rate 0: 0 L/min e operating pressure 0:.0 MPa : 0.6 MPa f Design No. Incremented at model changes,... g Function Option C: With communication function (RSC) P: With analog input function h Non-standard No. N: Without control system A: With control system 0

7 Main features and functions Features Energy-saving Daikin s original energy-saving motor technology utilizing high-efficiency IPM motors provides an energy-saving ratio of 0%. The motor rotation speed control controls the flow rate and pressure of the fixed displacement pump. The highly-efficient motor adopted in this unit achieves energy savings even in applications for general industrial machinery where actuators have high duty ratios. The single pump type is a highly-functional series to make it more useful. The double pump type uses the autonomously-switching, fixed-displacement double pump system, which combines large- and small-capacity pumps in the low pressure, high flow rate range, and autonomously switches to the single operation of the high-pressure, small capacity pump in the high pressure, low flow rate range. In this way, the double pump type ensures a higher energy-saving effect. Low noise Low noise level of db (A) (In the pressure retained operation at 0.6 MPa, with the double pump type unit) Even over the full operation range, noise is less than db (A). By using double phase-differential pumps, the Super Unit reduces pulsation and the noise level. * Data for SUTDL Excluded from high-efficiency motor regulations The Super Units that incorporate a high-efficiency IPM motor are excluded from high-efficiency motor regulations. Restricted oil temperature rise Motor speed control also leads to restriction of the oil temperature rise. The restricted oil temperature rise inhibits deterioration of the hydraulic oil. This also lowers the heat load for air conditioning equipment Fewer control valves required A wide variety of control can be achieved by adjusting parameter settings. Acceleration/deceleration operations that have been accomplished using proportional control valves may be replaced by simply setting the acceleration/deceleration time. Pressure switch may be reduced by using the pressure switch function. (Note that some kinds of control are not applicable depending on the customer s circuit. Care must be taken especially when controlling multiple axes.) List of Super Unit Models, Nomenclature, Main Features and Functions Functions Multi-stage pressure/flow rate control Sixteen pressure (P) - flow rate (Q) setting patterns are available for cylinder control. The proportional control valve and proportional pressure control valve, which are utilized in conventional actuator circuits, can be omitted. The pressure and flow rate can be set using the control unit s operation panel. The pressure and flow rate settings can be selected from among the sixteen patterns using external input signals. The Super Unit autonomously switches between the pressure control and flow rate control modes. Communication function (Available as an option with all models) Remote control and setting changes are possible through RSC serial communication. Using a commercially-available PLC or touch panel display with RSC communication capabilities, parameters for the pressure, flow rate, acceleration time, deceleration time and so on can be set and viewed at the machine. This facilitates control of speeds and pressurizing forces and enables a wide variety of machine operations. Maintenance/Management Function (Hybrid-Win) Internal data of the Super Unit PC tool can be obtained by using PC Supported connected to the unit. The pressure, flow rate, and other internal data of the controller can be monitored and displayed in graph form. This facilitates operation checks during test runs, adjustment of parameters such as time constants, and troubleshooting. The time required for setting can be slashed by editing the parameter settings on the PC and writing them to the unit in a batch. The ability to read and save settings facilitates management. Analog command input (Available as an option with single pump type models) Enables continuous control of pressures and speeds as required. The pressure and flow rate can be controlled continuously at the desired values by inputting the pressure command voltage (0 to 0 V) and flow rate command voltage (0 to 0 V) from the machine side. This achieves a control system with a simple configuration for machinery that requires variable speed control or continuity of pressurizing forces. Super Unit hydraulic circuits (example for the unit type) Single pump type Example with SUT0S0-. Refer to the Instruction Manual for each model for details because the port diameter varies depending on the model. Double pump type Example with SUT06D06-. Refer to the Instruction Manual for each model for details because the circuit configuration varies depending on the model. 6- Hose M C/R P T Optional port DR Rc⅜ Rc Rp⅜ Rp½ Rp¾ M Above oil level 6- Part No. Name Tank Suction strainer Stop valve Oil filler port-cum-air breather Oil level gauge 6- Controller 6- Motor pump incorporating an IPM motor Oil cooler Hose 6- M C/R T P B A P Rc¾ 9 b T Optional port DR Rc Rc¾ Rp⅜ Rp½ Rp¾ P (low pressure) P (high pressure) M Above oil level 6- Part No. Name Tank Suction strainer Stop valve Oil filler port-cum-air breather Oil level gauge 6- Controller 6- Motor pump incorporating an IPM motor Oil cooler Return filter 9 Check valve with holes Hose Hose Rc½ Hose Hose Hose Rc½ 06

8 Features With excellent energy-saving technology, the Super Unit can substantially reduce electricity costs. The control system can be easily upgraded by combining various Super Unit functions. Feature Energy-saving Excellent cost effectiveness with energy-saving ratio of 0% (In pressure retained operation at 0.6 MPa) Through servo control of Daikin s original high-efficiency IPM motor, the Super Unit ensures both a high response speed and stable rotation speed control with fixed-displacement pumps. In pressure holding mode, the Super Unit autonomously reduces the motor rotation speed to the minimum value required to hold the pressure, thus ensuring energy savings of 0% or higher (compared with the conventional Daikin variable piston pump). The Super Unit can even provide an energy-saving effect with general industrial machinery in which actuators provide a high duty ratio, as well as in pressure holding mode. Existing hydraulic unit Super Unit Power consumption (kw) 6 0 Operation time Power consumption (kw) 6 0 Operation time Comparison of annual power consumption Power consumption (kw) 6 0. kwh Existing hydraulic unit.6 kwh Super Unit Power consumption (average during operation) Approx. % reduction Annual energy-saving effect Decreased by $9. ( 9,00) [Estimation conditions] Existing hydraulic unit: double gear pump Model of Super Unit: SUT0D Cost of electricity: /kwh Annual operation time: 000 hours $: 00 POINT The solenoid operated relief valve used in the existing hydraulic unit is eliminated by pressure control with a Super Unit. This results in an approximately % reduction in power consumption. Feature Low noise Low noise level of db (A) (In pressure retained operation at 0.6 MPa, with the double pump type unit) Even over the full operation range, noise is less than db (A). Running the motor at the minimum required rotation speed in pressure holding mode achieves a remarkable noise level reduction. Examples of typical noise levels Ordinary conversation Suburban areas at night Noisy office In a bus or train In a subway train 90 db Full operation Quiet park range Low noise level Double pump type in pressure holding mode at 0.6 MPa Super unit It is generally known that ordinary conversation can be conducted with a person one meter away in an environment at a noise level of db (A). 0

9 Feature Feature Feature Feature 6 Excluded from high-efficiency motor regulations High-efficiency motor regulations came into effect in Japan in April 0. These regulations apply to the hydraulic units equipped with general motors but the Super Units that incorporate a high-efficiency IPM motor are excluded from them. Advantages of using hybrid hydraulic units All models conforming to CE standards Restricted oil temperature rise Improved machining accuracy Reduced thermal distortion improves the machining accuracy. Reduced air-conditioning heat load The reduced heat load on the air conditioner achieves further energy savings. Fewer control valves required Eliminates the need for replacement of motors for each destination Eliminates the need for design changes in accordance with amendments to the regulations Reduces design changes to spare parts, and the maintenance workload All models conform to the machinery directive, EMC directive, and low voltage directive. This facilitates CE approval of the main machine. Restriction of the temperature rise of the hydraulic fluid is one of the effects achieved by adopting Super Units. This generates the following advantages. Extended service life of packing and other sealing materials Improved maintainability Deterioration of the packing and other sealing materials that are made of rubber, used for hydraulic valves and hydraulic cylinders, is restricted. Extended service life of the hydraulic fluid Reduced environmental load and improved maintainability Restricted deterioration of the hydraulic fluid extends its replacement interval. Features Example hydraulic press circuit configuration Reducing the Number of Control Valves by Creating a Software-based System Configuration Throttle valve Elimination of the throttle valve Special spool shockless solenoid valve Standardization of the solenoid valve General-purpose solenoid valve Elimination of the proportional control valve Combination flow/single flow switching valve M Driver Proportional relief valve Control unit M Conventional system configuration Super Unit system configuration 0

10 Functions Function Multi-stage pressure/flow rate control (6 PQ control setting patterns) Featured with standard models The force (pressure) and speed (flow rate) of the actuator (cylinder) can be controlled with 6 pressure (P) and flow rate (Q) setting patterns. The proportional control valve and proportional pressure control valve, which are utilized in conventional actuator circuits, are not required. Once the pressure and flow rate have been set at the controller s operation panel, you can select 6 preset patterns using external input signals. The Super Unit autonomously changes the control mode from flow rate control to pressure control (example: flow rate control is changed to pressure control at the cylinder stroke end). The solenoid valve that actuates the cylinder must be turned ON/OFF at the machine. Smooth changing of force (pressure) and speed (flow rate) Once acceleration time and deceleration time parameters are registered, the force or speed can be changed gradually during a pressure/flow rate setting change. Example of PQ control setting patterns PQ selection 0 PQ selection PQ selection PQ selection PQ Pattern selection: 0 Pressure: MPa PQ Pattern selection: Pressure: MPa PQ Pattern selection: Pressure: MPa PQ Pattern selection: Pressure: MPa Speed (mm/s) Pressurizing force (kn) 0 0 Deceleration low speed Pressurizing force Cylinder speed 00 0 Pressure release* 0 0 Lowered at high speed Pressurizing Raised Meter-in control is (-stage pressuring) performed for pumps PQ Time (sec) PQ selection 0 PQ selection selection PQ selection PQ selection 0 PQ pattern selection *: When pressure release control is disabled, an additional pressure release circuit should be provided for the load side. Function Maintenance/Management function (Hybrid-Win) Featured with standard models PC tool Supported This PC utility reads data from Daikin hybrid systems (Super Unit, EcoRich, oil cooling unit, etc.) and manages it. Parameter setting and monitoring can be accomplished efficiently using the Windows application. Main features Displaying graphs The pressure, flow rate, and other internal data of the controller can be monitored and displayed in graph form. This facilitates operation checks during test runs, adjustment of parameters such as time constants, and troubleshooting. Reading, writing, editing, and saving parameters The time required for setting can be slashed by editing the parameter settings on the PC and writing them to the unit in a batch. The ability to read and save settings facilitates management. Reading and saving the alarm history This function enables quick identification of the parts that require maintenance and reduction of the downtime. The operating time display can serve as the guide for the timing to replace consumable parts or to conduct maintenance. Troubleshooting information including the diagnosis results of the cause of an alarm and action to take can be displayed. Communication cable *: Hybrid-Win is utility software to monitor the internal status of Daikin hybrid systems using a PC. The software and its instruction manual can be downloaded from the website free of charge by completing the user registration process. *: The communication cable is separately available. *: Some models require a dedicated separate monitor harness. *: It is possible to connect to a smart phone or factory LAN by adding an optional WiFi module. This is useful to facilitate the user s daily inspection/maintenance work and for remote monitoring. PC (to be prepared by the customer) Super Unit 09

11 Function Option Optional function C Communication function The Super Unit and main machine can be remotely controlled with the same panel. This function eliminates complicated individual operations and installation space limitations. Remote setting of the operating conditions of the Super Unit enabled Various settings such as acceleration/deceleration time and pressure switch settings, as well as the pressure and flow rate, can be set remotely. This makes it possible to control the hydraulic pressure operating conditions in synchrony with the control of the machine. Managing the pressure and flow rate at the machine The capability to read the operating conditions of the Super Unit makes it possible to display information such as the current pressure and flow rate on the screen at the machine. *: The serial communication interface conforms to the RSC standard. (For RS interfaces, consult Daikin.) Prepare a control unit such as a PLC or touch panel display with the RSC communication function at the machine side. *: For details on the communication procedure, refer to the communication/remove control function instruction manual. Application of Super Unit Remote Operation and Communication Functions Installation in an elevated position or at a distance (within m) Functions Function Option Setting and monitoring P (pressure), Q (flow rate), and other data from the machine control panel Optional function P Analog command input The capability to specify the pressure and flow rate with voltage ranging from 0 to 0 V enables continuous hydraulic control as required. Real-time variation in response to commands facilitates condition settings at the machine side. A hydraulic control system for machinery that requires variable speed control or continuity of pressurizing forces can be realized with a simple configuration. A joystick or trimmer can be connected for real-time control. 0

12 Hardware Option Hardware option 0 Hardware option 0 With unit cover Optionally available for units with tank capacities of L, 00 L, and L (SUT06S6- excluded) The cover protects the controller unit and piping. With controller cover Optionally available for models with motor capacities equivalent to. kw,. kw,. kw, and kw The metal cover protects the controller unit. Example of unit cover installation Example of controller cover installation Hardware option 0 With DCL (DC reactor) Optionally available for models with motor capacities equivalent to. kw,. kw,. kw, and kw Appropriate when it is necessary to improve the power factor or reduce the harmonics of the power supply Optionally available for compact models with the capacity of kw or smaller. Provided as standard for models with a capacity of kw or greater. Hardware option 0 Separate power supplies for power system and control system Optionally available for units with motor capacities equivalent to. kw,. kw,. kw, kw, and kw When an error occurs, only the main power supply is shut down and control power supply continues to carry current, thereby enabling the alarm code and internal status on occurrence of an error to be checked on the operation panel or through serial communication. Hardware option 0 Water fill test compliant tank Hardware option 06 Water leak test compliant tank Optionally available with all unit type models The water fill test, one of the adaptation criteria for the Fire Service Act, and the water leak test, Daikin original standard, are carried out. The tanks that pass the tests have compliance s affixed and are delivered with the certificate. (Water fill test compliant tanks are not equivalent to Fire Service Act compliant tanks.)

13 Hardware option 0 Level switch Hardware option 0 Temperature switch Hardware option 09 Thermometer Hardware option 0 Micro separator Optionally available with all unit type models The accessories that can be fitted to the tank are provided as optional parts. The accessories can be purchased separately as optional parts. (See Page.) List of Models with Options Installed Function Option Hardware Option Pump specifications Motor capacity C P With unit cover (0) With controller cover (0) With DCL (0) Separated power supply for power/ Tank inspection/ control systems (0) unit accessory (*).kw. kw SUT00S0- SUT0S0- SUT00S0- SUT0S0- SUT00S0- SUT0S0- Hardware Option SUT00S00- SUT0S00- Single pump. kw SUT00S0- SUT0S0- SUT00S6- SUT0S6-.0 kw SUT00S6- SUT06S6- SUT00S0- SUT06S0- SUT00S00-.0 kw SUT0S00-. kw SUT00D06- SUT06D06- Double pump.0 kw SUT00D- SUT06D- SUT0D-.0 kw SUT00D0- SUT0D0- SUT6D0- * Tank inspections : Water fill test compliant tank (0), water leak test compliant tank (06) Unit accessories : Level switch (0), temperature switch (0), thermometer (09), microseparator (0) Available Not available

14 Pressure Flow Rate Characteristics (Typical) Single pump type SUTS0, SUTS0, SUTS00, SUTS0, SUTS00, SUTS SUTS SUTS00 Flow rate (L/min) SUTS0 SUTS00 SUTS0 SUTS Pressure (MPa) * Operating flow rate at the maximum pressure in continuous operation: SUTS0: L/min maximum SUTS0: L/min maximum SUTS00: L/min maximum SUTS0: L/min maximum SUTS00: 9 L/min maximum SUTS00: 6 L/min maximum SUTS0, SUTS Flow rate (L/min) SUTS0 SUTS Pressure (MPa) * Operating flow rate at the maximum pressure in continuous operation: SUTS0: L/min maximum SUTS0: L/min maximum SUTS6, SUTS Flow rate (L/min) SUTS6 SUTS Pressure (MPa) * Operating flow rate at the maximum pressure in continuous operation: SUTS6: L/min maximum SUTS6: L/min maximum

15 Double pump type SUTD06 SUTD Flow rate (L/min) 0 0 Flow rate (L/min) Pressure (MPa) * Operating flow rate at the maximum pressure in continuous operation: L/min maximum SUTD Pressure (MPa) * Operating flow rate at the maximum pressure in continuous operation: 6. L/min maximum SUTD Pressure Flow Rate Characteristics (Typical) Flow rate (L/min) 0 0 Flow rate (L/min) Pressure (MPa) Pressure (MPa) * Operating flow rate at the maximum pressure in continuous operation: L/min maximum * Operating flow rate at the maximum pressure in continuous operation: 6 L/min maximum

16 Super Unit [Single pump type] operating pressure MPa Pressure Flow rate characteristics (Representative) flow rate / L/min 0 00 SUTS00 SUTS0- SUTS0- Flow rate (L/min) SUTS00 SUTS0 SUTS00 SUTS0 0 0 SUTS0 Tankless type Unit type Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: SUTS0: L/min maximum SUTS0: L/min maximum Specifications SUT00S0- Tankless type SUT00S0- SUT0S0- Unit type SUT0S0- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Operating conditions Motor pump/unit AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) External input signal External Digital output output signal Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color.. to.. kw.. to.. kw.0. to.0 -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%) channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) 9 9 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 0 Volumetric water content: 0.% maximum.. to.. kw 0 to C (Recommended operating temperature range: to 0 C).. to.. kw 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

17 External Dimension Diagram Tankless type SUT00S0- SUT00S0- Pressure indication and operation panel P Rc⅜ Part No. Name Quantity - Motor pump incorporating an IPM motor - Controller () (6) AC fan Base 90 0 () -φ0 holes (for fixing bolts) (M bolts recommended) φ hole (Power cable port) φ hole (Signal cable port) - () DR Rc⅜ Wing bolt for fastening during transportation (at location) (To be removed before operation) () (66) (0) Suction air Unit ******** Unit (09) - (6) () Unit type 9 T Rc Optional port: Rp⅜ (0) φ hole (Signal cable port) DR Rp¾ (above oil level) Optional port: Rp½. 0 () () 0 Pressure indication and operation panel () 6- -M (Manifold bracket mount) (Manifold bracket mount) P Rc⅜ 0 (0) Foundation plate (Option) (E-SUTPLATE-) -φ holes (for fixing bolts) (M bolts recommended) 0 SUT0S0- SUT0S0- Part No. Name Quantity Oil tank Suction strainer Stop valve Oil level gauge Oil filter port-cum-air bleeder 6- Motor pump incorporating an IPM motor 6- Controller Oil cooler AC fan Suction port: G¾ Cleaning port Specifications/External Dimension Diagram MPa / L/min φ hole (Power cable port) SUT0SL0- Unit L Upper limit (Yellow line) L Lower limit (Red line) Cleaning port tightening caution Suction air (6) 9 (0) 6 Oil sampling port/ Oil drain port: Rc½ Wing bolt for fastening during transportation (at location on the back) (To be removed before operation) -M (through hole) Tapped holes for mounting the foundation plate (at locations) 0 00 (0) (0) 6

18 Super Unit [Single pump type] operating pressure MPa Pressure Flow rate characteristics (Representative) flow rate 0 L/min 0 00 SUTS00 SUTS SUTS00 Flow rate (L/min) 0 0 SUTS0 SUTS00 SUTS0 0 0 SUTS0 Tankless type Pressure (MPa) Unit type * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: L/min maximum Specifications Tankless type SUT00S00- Unit type SUT0S00- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Motor pump/unit AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) External input signal External Digital output output signal Contact output Mass (kg) Operating conditions Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color to 9.. to.0. kw -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%) channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) 6 6 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 0 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

19 External Dimension Diagram Tankless type P Rc½ Pressure indication and operation panel SUT00S00- Part No. Name Quantity - Motor pump incorporating an IPM motor - Controller (9) (0) AC fan Base 90 0 () -φ0 holes (for fixing bolts) (M bolts recommended) φ hole (Power cable port) φ hole (Signal cable port) - () DR Rc⅜ Wing bolt for fastening during transportation (at location) (To be removed before operation) () (66) 0 Suction Unit air Suction air (0) - () (9) Unit type T Rc DR Rp¾ (above oil level) φ hole (Signal cable port) -M (Manifold bracket mount) Pressure indication and operation panel 96 (0) () (0) Optional port: Rp½ 0. Optional port: Rp⅜ P Rc½ Foundation plate (Option) (E-SUTPLATE-) -φ holes (for fixing bolts) (M bolts recommended) 0 SUT0S00- Part No. Name Quantity Oil tank Suction strainer Stop valve Oil level gauge Oil filler port-cum-air breather 6- Motor pump incorporating an IPM motor 6- Controller Suction port: G¾ Oil cooler AC fan Cleaning port Specifications/External Dimension Diagram MPa 0 L/min φ hole (Power cable port) Suction air EHU0R-M0- EHU0R-M0- Unit L Upper limit (Yellow line) L Lower limit (Red line) 6-9 (6) (9) Cleaning port tightening caution 6 Oil sampling port/ Oil drain port: Rc½ 0 0 Bolt Caution 0 0 -M (through hole) Tapped holes for mounting the foundation plate (at locations) 0 Wing bolt for fastening during transportation (at location on the back) (To be removed before operation) 9 (0) 0 00 (0) (0)

20 Super Unit [Single pump type] operating pressure MPa Pressure Flow rate characteristics (Representative) flow rate L/min 0 00 SUTS00 SUT00S0- SUT06S0- Flow rate (L/min) : 0 SUTS00 SUTS0 SUTS00 SUTS0 0 0 SUTS0 Tankless type Pressure (MPa) Unit type * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: L/min maximum Specifications Tankless type SUT00S0- Unit type SUT06S0- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Motor pump/unit AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) Operating conditions External input signal External Digital output output signal Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color to 6.. to.0.0 kw -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%).. 0. channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) 6 9 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 0 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. 9

21 External Dimension Diagram Tankless type Pressure indication and operation panel Unloading port Rc½ SUT00S0- (0) P Rc¾ Part No. Name Quantity - Motor pump incorporating an IPM motor - Controller AC fan Base Check valve (9) (6) (9) (0) () -φ0 holes (for fixing bolts) (M bolts recommended) φ hole (Power cable port) φ hole (Signal cable port) - DR Rc⅜ Wing bolt for fastening during transportation (at location) (To be removed before operation) () (66) () Suction air Unit ******** Unit - (9) (6) () Unit type T Rc T Rc¾ (Plugged at shipment) Optional port: Rp⅜ Optional port: Rp½ 0 -φ holes (for fixing bolts) (M bolts recommended) (0) 00 DR Rp¾ (above oil level) 0 -M (Manifold bracket mount) Suction port: Rc P Rc¾ Foundation plate (Option) Pressure indication and operation panel (E-SUTPLATE-) () (0) () SUT06S0- () (6) Part No. Name Quantity Oil tank Suction strainer Stop valve Oil level gauge Oil filler port-cum-air breather 6- Motor pump incorporating an IPM motor 6- Controller Oil cooler AC fan 9 Return filter 0 Check valve Specifications/External Dimension Diagram MPa L/min Safety Unit caution Unit L Upper limit (Yellow line) L Lower limit (Red line) 6 9 Suction air 6- () Cleaning port tightening caution Cleaning port Wing bolt for fastening during transportation (at location on the back) 0 0 (To be removed before operation) () Bolt Caution 9 -M (through hole) Tapped holes for mounting the foundation plate (at locations) (0) 0 00 Oil sampling port/ Oil drain port: Rc½ 0

22 Super Unit [Single pump type] operating pressure MPa Pressure Flow rate characteristics (Representative) flow rate 0 L/min 0 00 SUTS00 SUTS SUTS00 Flow rate (L/min) 0 0 SUTS0 SUTS00 SUTS0 0 0 SUTS0 Tankless type Pressure (MPa) Unit type * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: 9 L/min maximum Specifications Tankless type SUT00S00- Unit type SUT0S00- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Motor pump/unit AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) Operating conditions External input signal External Digital output output signal Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color to.0. to.0.0 kw -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%)... 0 channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 0 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. 00 Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

23 SUT0D0L0- External Dimension Diagram Tankless type Motor cable Pressure indication and operation panel (9) SUT00S00- P Rc¾ Part No. Name Quantity - Motor pump incorporating an IPM motor - Controller AC fan Base 9 Unloading port: Rc½ () (96) Check valve () 0 6 () -φ0 holes (for fixing bolts) (M bolts recommended) - DR Rc⅜ - () (6) () Suction air Unit (.) () (0) (0) Unit type T Rc-¼ (Plugged at shipment) T Rc-½ () 0 00 DR Rp¾ (above oil level) () () -M (Manifold bracket mount) Pressure indication and operation panel Optional port: Rp⅜ Optional port: Rp½ P Rc¾ -φ holes (for fixing bolts) (Fitted with a vinyl cap (M bolts recommended) at shipment) (0) () (0) Foundation plate (Option) (E-SUTPLATE-) (9) Wing bolt for fastening during transportation (at locations) (To be removed before operation) Transportation SUT0S00- () (90) Suction port: Rc (Plugged (with O-ring) at shipment) Part No. Name Quantity Oil tank Suction strainer Stop valve Oil level gauge Oil filler port-cum-air breather 6- Motor pump incorporating an IPM motor 6- Controller Oil cooler AC fan 9 Return filter 0 Check valve Cleaning port Specifications/External Dimension Diagram MPa 0 L/min (6) Suction air () 0 (9) Wing bolt for fastening during transportation (at location on the back) (To be removed before operation) Bolt Caution () -M (through hole) Tapped holes for mounting the foundation plate (at locations) (0) Unit Cleaning port tightening caution 00 L Upper limit (Yellow line) 6 L Lower limit (Red line) (6) Oil sampling port/ Oil drain port: Rc½

24 Super Unit [Single pump type] operating pressure MPa Pressure Flow rate characteristics (Representative) flow rate 0 L/min 0 00 SUTS00 SUT00S SUTS00 Flow rate (L/min) 0 0 SUTS0 SUTS00 SUTS0 0 0 SUTS0 Tankless type Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: 6 L/min maximum Specifications Tankless type SUT00S00- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Motor pump AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) Operating conditions External input signal External Digital output output signal Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color 0.0. to 0. to.0.0 kw -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%)...9 channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 0 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

25 I Disconnect all power before opening terminal cover of unit. Wait minutes until DC Bus capacitors dischange. MFG No.: Note. MASS : kg INSULATION CLASS: F V Hz MAX. FLOW : 0 L/min φ 00 0: 6 A 0.9 PF MAX.PRESSURE :.6 MPa φ φ DAIKIN INDUSTRIES,LTD. MADE IN JAPAN DAIKIN INDUSTRIES,LTD. MADE IN JAPAN DAIKIN INDUSTRIES,LTD. MADE IN JAPAN External Dimension Diagram Tankless type Suction port: Rc-¼ 9 SUT00S00- Encoder wiring connector 0 D EC NC 6 Discharge port Rc-¼ 9 9 &ast;&ast; Drain port Rc⅜ Unloading port Rc¾ Motor wiring port (φ) AC fan, thermistor wiring port (φ) Suction air 0 -. (Installation) Control unit 0 0 SUT00S00- SUT00D0- Controller (Installed separately) Cooling fan Cooling fan Controller installation hole -φ (M6 bolts recommended) Specifications/External Dimension Diagram. <Top> Cooling fan exhaust Cooling fan suction () User I/O terminal (M) Encoder Motor thermistor Pressure sensor I/O signal. Controller M screw (for ground connection) 6 6. FG FG GND +V Z- Z+ B- B+ A- A+ THM- THM+ AGND AO (QO) AGND AO (PO) AGND AIN (QI) AGND AIN (PI) AGND P_S AV ALM_C ALM_B ALM_A DOCOM DO DO6 DO DO DO DO DO DI DI DI6 DI DI DI DI DI DICOM DGND RxD TxD FG FG 0 WARNING May cause electric shock. DAIKIN INDUSTRIES,LTD. 0 () 0 MFG No.: MASS : kg INSULATION CLASS: F V Hz A MAX.FLOW : L/min φ 00 0 MAX.PRESSURE : MPa φ 00 φ 0 PF Operation panel Product Main power supply terminal block (M) Main power supply DC reactor Regenerative resistor Motor output Electromagnetic valve terminal block (M) Electromagnetic valve power supply AC fan power supply M screw (for ground connection) M screw (for ground connection) () () MPa 0 L/min

26 Super Unit [Single pump type] operating pressure flow rate SUTS0-0 MPa L/min Flow rate (L/min) Pressure Flow rate characteristics (Representative) SUTS0 0 SUTS0 0 Tankless type Unit type Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: L/min maximum Specifications Tankless type SUT00S0- Unit type SUT0S0- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Motor pump/unit AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) Operating conditions External input signal External Digital output output signal Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color to.. to 0.0. kw -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%).0.. channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) 9 9 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 9 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 0 for operating pressures of MPa or lower. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

27 External Dimension Diagram Tankless type SUT00S0- P Rc⅜ Pressure indication and operation panel Part No. Name Quantity - Motor pump incorporating an IPM motor - Controller () AC fan (6) Base φ hole (Power cable port) φ hole (Signal cable port) () -φ0 holes (for fixing bolts) (M bolts recommended) () DR Rc⅜ (Fitted with a vinyl cap at shipment) Wing bolt for fastening during transportation (at location) (To be removed before operation) () (66) Suction air Unit - (0) (6) () (09) 0 Suction port: G¾ (Fitted with a vinyl cap at shipment) Unit type 9 T Rc (Fitted with a vinyl cap at shipment) Optional port: Rp⅜ DR Rp¾ (above oil level) -M (Manifold bracket bracket mount) mount) Optional port: Rp½ 00 0 P Rc⅜ SUT0S0- Part No. Name Quantity Oil tank Suction strainer Stop valve Oil level gauge Specifications/External Dimension Diagram Oil filter port-cum-air bleeder (0) 0. Pressure indication and operation panel 96 () (0) Foundation plate (Option) (E-SUTPLATE-) -φ holes (for fixing bolts) (M bolts recommended) 6- Motor pump incorporating an IPM motor 6- Controller Oil cooler AC fan 0 MPa φ hole (Signal cable port) 6- Cleaning port L/min φ hole (Power cable port) Suction air SUT0SL0- Unit L Upper limit (Yellow line) L Lower limit (Red line) 6-9 (6) 9 Cleaning port tightening caution 6 Oil sampling port/ Oil drain port: Rc½ 0 0 Bolt Caution Wing bolt for fastening during transportation -M (through hole) (at location on the back) (To be removed before operation) Tapped holes for mounting the foundation plate (at locations) 0 00 (0) (0) 6

28 Super Unit [Single pump type] operating pressure flow rate SUTS0-0 MPa L/min Flow rate (L/min) Pressure Flow rate characteristics (Representative) SUTS0 0 SUTS0 0 Tankless type Pressure (MPa) Unit type * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: L/min maximum Specifications Tankless type SUT00S0- Unit type SUT0S0- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Motor pump/unit AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) Operating conditions External input signal External Digital output output signal Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color to.6. to 0.0. kw -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%) channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) 6 6 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 9 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 0 for operating pressures of MPa or lower. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

29 External Dimension Diagram Tankless type SUT00S0- Pressure indication and operation panel P Rc⅜ Part No. Name Quantity - Motor pump incorporating an IPM motor - Controller AC fan (9) (0) Base 90 () -φ0 holes (for fixing bolts) (M bolts recommended) 0 φ hole (Power cable port) φ hole (Signal cable port) - DR Rc⅜ () Wing bolt for fastening during transportation (at location) (To be removed before operation) () (0) (66) 0 Suction air Unit - () (9) Unit type 9 T Rc (Fitted with a vinyl cap at shipment) Optional port: Rp⅜ (0) DR Rp¾ (above oil level) -M (Manifold bracket mount) 00 0 Optional port: Rp½ 0 Pressure indication and operation panel 96 () (0) Foundation plate (Option) (E-SUTPLATE-) -φ holes (for fixing bolts) (M bolts recommended) P Rc⅜ 0 SUT0S0- Part No. Name Quantity Oil tank Suction strainer Stop valve Oil level gauge Oil filler port-cum-air breather 6- Motor pump incorporating an IPM motor 6- Controller Suction port: G¾ Oil cooler AC fan Specifications/External Dimension Diagram 0 MPa φ hole (Signal cable port) φ hole (Power cable port) Suction air 6- SUT0SL0- Unit L Upper limit (Yellow line) L Lower limit (Red line) 6-9 (6) Cleaning port tightening caution Cleaning port 6 L/min 0 0 Bolt Caution 9 (9) (0) 0 0 Wing bolt for fastening during transportation (at location on the back) (To be removed before operation) 0 -M (through hole) Tapped holes for mounting the foundation plate (at locations) 0 00 (0) (0) Oil sampling port/ Oil drain port: Rc½

30 Super Unit [Single pump type] operating pressure 6 MPa Pressure Flow rate characteristics (Representative) flow rate L/min SUTS6- SUTS6- Flow rate (L/min) SUTS6 SUTS Tankless type Unit type Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: L/min maximum Specifications Tankless type Unit type SUT00S6- SUT00S6- SUT0S6- SUT06S6-9 Pump unit Motor capacity Power supply Rated current (A) Operating conditions flow rate (theoretical value; L/min) * operating pressure (MPa) Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity (equivalent kw) Motor pump/unit AC φ00v (0 Hz) AC φ00v ( Hz) AC φ0v ( Hz) Power source breaker setting (A) External output signal External input signal Digital output Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color to.. to.6. to.. to.6. to 6.0. kw.0 kw. kw.0 kw -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%) channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) 6 6 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 9 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 0 for operating pressures of MPa or lower. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

31 External Dimension Diagram (0) P Rc⅜ (9) SUT00S6- SUT00S6- Name Quantity - Motor pump incorporating an IPM motor - Controller AC fan Base φ hole (Power cable port) φ hole (Signal cable port) -φ0 holes (for fixing bolts) (M bolts recommended) () ( ) ( 90) ( 0) Part No. Pressure indication and operation panel Tankless type - DR Rc⅜ Oil filler port-cum-air breather φ hole (Signal cable port) 6- Motor pump incorporating an IPM motor φ hole (Power cable port) Tapped holes for mounting the foundation plate (at locations) Quantity Oil tank T Rc¾ (Plugged at shipment) Suction strainer Optional port: Rp⅜ Stop valve Optional port: Rp½ Oil level gauge Oil filler port-cum-air breather 6- Motor pump incorporating an IPM motor 6- Controller MPa Unit 6- Suction air / L/min L Lower limit (Red line) Wing bolt for fastening during transportation (at location on the back) (To be removed before operation) L Upper limit (Yellow line) Cleaning port 9 Return filter Foundation plate (Option) (E-SUTPLATE-) (0) () 0 AC fan 6 P Rc⅜ -φ holes (for fixing bolts) (M bolts recommended) (0) 0 Oil cooler Oil sampling port/ Oil drain port: Rc½ Pressure indication and operation panel Name M (through hole) 0 Part No. DR Rp¾ (above oil level) 6 -M 0 (Manifold bracket mount) 00 T Rc 0 Wing bolt for fastening during transportation (at location on the back) (To be removed before operation) SUT06S M (through hole) Tapped holes for mounting the foundation plate (at locations) (0) AC fan L Lower limit (Red line) Suction air L Upper limit (Yellow line) Cleaning port 9 Oil cooler SUT03S15L1630 Controller Foundation plate (Option) (E-SUTPLATE-) (0) () Specifications/External Dimension Diagram Oil level gauge (0) 69 6 Pressure indication and operation panel -φ holes (for fixing bolts) (M bolts recommended) 6 (0) Stop valve Suction strainer (9) P Rc⅜ (6) 9 Quantity Oil tank () Name Optional port: Rp½ 0 Part No. Suction port: G¾ (Fitted with a vinyl cap at shipment) ( ): Dimensions for SUT00S T Rc (Fitted with a vinyl cap at shipment) Optional port: Rp⅜ 0 SUT0S6- -M (Manifold bracket mount) 9 DR Rp¾ (above oil level) - ( ) ( 0) Unit type () Unit () 0 (To be removed before operation) ******** () Suction air Wing bolt for fastening during transportation (at location) (09) (66) () () ( ) Unit 0 00 Oil sampling port/ Oil drain port: Rc½

32 Super Unit [Double pump type] operating pressure flow rate SUTD06- Tankless type 6 MPa 0 Unit type L/min Flow rate (L/min) Pressure Flow rate characteristics (Representative) Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: L/min maximum Specifications Tankless type SUT00D06- Unit type SUT06D06- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Motor pump/unit AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) Operating conditions External input signal External Digital output output signal Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color.. to.0. to.. kw -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%) channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) 9 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 9 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 0 for operating pressures of MPa or lower. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing..0

33 External Dimension Diagram Tankless type Pressure indication and operation panel Unloading port Rc½ SUT00D06- (6) P Rc¾ Part No. Name Quantity - Motor pump incorporating an IPM motor - Controller AC fan Base Check valve φ hole (Power cable port) φ hole (Signal cable port) (9) - () (9) (0) () -φ0 holes (for fixing bolts) (M bolts recommended) DR Rc⅜ Wing bolt for fastening during transportation (at location) (To be removed before operation) () (66) 0 Unit Suction air Unit - (9) (6) () (9) (9) Suction port: Rc Unit type T Rc 0 T Rc¾ (Plugged at shipment) Optional port: Rp⅜ Optional port: Rp½ -φ holes (for fixing bolts) (M bolts recommended) (0) 00 9 DR Rp¾ (above oil level) M (Manifold bracket mount) Pressure indication and operation panel 00 0 () (0) 6-0 (9) P Rc¾ Foundation plate (Option) (E-SUTPLATE-) SUT06D06- Part No. Name Quantity Oil tank Suction strainer Stop valve Oil level gauge Oil filler port-cum-air breather 6- Motor pump incorporating an IPM motor 6- Controller Oil cooler AC fan 9 Return filter 0 Check valve Specifications/External Dimension Diagram 6 MPa Unit L Upper limit (Yellow line) L Lower limit (Red line) 0 L/min Cleaning port tightening caution Cleaning port 69 6 Suction air () 0 0 Bolt Caution Wing bolt for fastening during transportation (at location on the back) 0 0 (To be removed before operation) 0 9 -M (through hole) Tapped holes for mounting the foundation plate (at locations) (0) 0 00 Oil sampling port/ Oil drain port: Rc½

34 Super Unit [Double pump type] operating pressure flow rate SUTD- Tankless type MPa Unit type L/min Flow rate (L/min) Pressure Flow rate characteristics (Representative) Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: 6. L/min maximum Specifications Tankless type Unit type SUT00D- SUT06D- SUT0D- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Motor pump/unit AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) Operating conditions External input signal External Digital output output signal Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color 0.6. to 6.. to kw -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%).. 0. channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) 99 Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 9 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. 00 Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 0 for operating pressures of MPa or lower. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing. 6.

35 External Dimension Diagram P Rc¾ (0) Suction air Oil level gauge Oil filler port-cum-air breather 6- Motor pump incorporating an IPM motor 6- Controller Oil cooler AC fan 9 Return filter 0 Check valve Foundation plate (Option) (E-SUTPLATE-) 0 6- Wing bolt for fastening during transportation (at location on the back) (To be removed before operation) Oil level gauge Oil filler port-cum-air breather 6- Motor pump incorporating an IPM motor 6- Controller Oil cooler AC fan 9 Return filter 0 Check valve (9) Stop valve Optional port: Rp½ P Rc¾ -φ holes (for fixing bolts) (M bolts recommended) (0) () Cleaning port 0 Foundation plate (Option) (E-SUTPLATE-) (0) 00 L Upper limit (Yellow line) 6 L Lower limit (Red line) 6- Suction air 0 0 Wing bolt for fastening during transportation (at location on the back) (To be removed before operation) 0 -M (through hole) Tapped holes for mounting the foundation plate (at locations) MPa L/min () T Rc¾ (Plugged at shipment) Optional port: Rp⅜ 9 Suction strainer T Rc (Fitted with a vinyl cap at shipment) Oil sampling port/ Oil drain port: Rc½ -M (Manifold bracket mount) 6 Oil tank Cleaning port M (through hole) Tapped holes for mounting the foundation plate (at locations) 0 L Lower limit (Red line) Oil sampling port/ Oil drain port: Rc½ 0 Quantity L Upper limit (Yellow line) 0 Name Cleaning port tightening caution 6 9 Part No. Unit Suction air DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) SUT0D- 6-9 Specifications/External Dimension Diagram -φ holes (for fixing bolts) (M bolts recommended) () 9 Stop valve P Rc¾ Optional port: Rp½ 00 0 (0) DR Rp¾ (above oil level) -M 0 (Manifold bracket mount) Suction strainer Suction port: Rc (Fitted with a vinyl cap at shipment) 0 Oil tank (.) 00 0 (6) Optional port: Rp⅜ 6 9 Quantity - T Rc¾ (Plugged at shipment) Name Unit 00 0 SUT06D- Part No. 0 T Rc () () Wing bolt for fastening during transportation (at location) (To be removed before operation) Unit type DR Rc⅜ () 69 6 Check valve 69 6 (9) (6) Base (9) Unloading port Rc½ - (0) -φ0 holes (for fixing bolts) (M bolts recommended) (6) AC fan Pressure indication and operation panel (0) Controller φ hole (Signal cable port) - φ hole (Power cable port) (9) Quantity Motor pump incorporating an IPM motor Name - (66) Part No. SUT00D- (9) () Tankless type

36 Super Unit [Double pump type] operating pressure flow rate SUTD0- Tankless type MPa 0 Unit type L/min Flow rate (L/min) Pressure Flow rate characteristics (Representative) Pressure (MPa) * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: L/min maximum Specifications Tankless type Unit type SUT00D0- SUT0D0- SUT6D0- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Motor pump/unit AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) Operating conditions External input signal External Digital output output signal Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color to.0. to kw -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%)... 0 channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 9 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. 00 Ivory white (Munsell code Y./) Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 0 for operating pressures of MPa or lower. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing..0

37 External Dimension Diagram Tankless type Motor cable Pressure indication and operation panel (9) P Rc¾ SUT00D0- Unloading port: Rc½ Part No. Name Quantity - Motor pump incorporating an IPM motor - Controller AC fan Base Check valve 9 (9) -φ0 holes (for fixing bolts) (M bolts recommended) 0 () 6 () (96) - DR Rc⅜ () Suction air Unit () - (99) () (0) Transportation (90) Unit type T Rc-½ T Rc-¼ (Plugged at shipment) () Optional port: Rp⅜ Optional port: Rp½ 0 -φ holes (for fixing bolts) (M bolts recommended) (0) M (Manifold bracket mount) () Wing bolt for fastening during transportation (at locations) (To be removed before operation) 0 00 (69)(9) DR Rp¾ (above oil level) (Fitted with a vinyl cap at shipment) P Rc¾ Foundation plate (Option) (E-SUTPLATE-) () (0) SUT0D0- SUT6D0- Suction port: Rc (Plugged (with O-ring) at shipment) Part No. Name Quantity Oil tank Suction strainer Stop valve Oil level gauge Oil filler port-cum-air breather 6- Motor pump incorporating an IPM motor 6- Controller Oil cooler AC fan 9 Return filter 0 Check valve Cleaning port Specifications/External Dimension Diagram Unit 6 L (00 L) Upper limit (Yellow line) L (6 L) Lower limit (Red line) MPa 6 9 (6) Wing bolt for fastening during transportation (at location on the back) (To be removed before operation) Suction air (9.) 6-9 () -M (through hole) Tapped holes for mounting the foundation plate (at locations) (0) Cleaning port tightening caution (0) 0 (6) 90 (0) (6) Oil sampling port/ Oil drain port: Rc½ (): Dimensions for SUT0D0-0 L/min 6

38 Super Unit [Double pump type] operating pressure flow rate SUT00D0- P-SUT0DKW- Tankless type MPa 0 L/min Flow rate (L/min) Pressure Flow rate characteristics (Representative) Pressure (MPa) Unit type * The graph shows actual flow rates (representative values). * Operating flow rate at the maximum pressure in continuous operation: 6 L/min maximum Specifications Tankless type SUT00D0- Unit type P-SUT0DKW- flow rate (theoretical value; L/min) * operating pressure (MPa) Pump unit Operating flow rate adjustment range (L/min) Operating pressure adjustment range (MPa) Motor capacity Motor capacity (equivalent kw) Power supply Motor pump/unit AC φ00v (0 Hz) Rated current AC φ00v ( Hz) (A) AC φ0v ( Hz) Power source breaker setting (A) Operating conditions External input signal External Digital output output signal Contact output Mass (kg) Usable oil * Operating hydraulic oil temperature (in tank) Operating ambient temperature Storage ambient temperature Operating ambient humidity Installation site Others Tank capacity (L) Standard coating color 0.6. to 0. to 0.6 -phase, 00 V (0 Hz), 00 V ( Hz), 0 V ( Hz) (Permissible voltage fluctuation: ±0%)...9 channels Photo-coupler insulation, DC V (DC V maximum), ma/channel channels, photo coupler insulation, FET output, DC V, 0 ma maximum per channel channel ( common contact), dry contact Contact capacity: DC V, 0. A (resistance load) Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil Viscosity grade: ISO VG to 6 Viscosity range: to 00 mm /s Contamination: Within NAS class 9 Volumetric water content: 0.% maximum 0 to C (Recommended operating temperature range: to 0 C) 0 to 0 C 0 to C % RH max. (no condensation) Indoors (Be sure to secure the unit with bolts.) Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker. Make sure that the electrical wiring meets the requirements of European Standard EN0-. Frequent turning this unit s power supply ON/OFF will considerably shorten the control unit s service life. To start or stop the unit at -minute or shorter intervals, use the unit s control stop function. Be sure to connect the ground terminal. 00 Ivory white (Munsell code Y./) 0 kw Note) *: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value. *: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic fluid within NAS contamination class 0 for operating pressures of MPa or lower. *: The unit incorporates a safety valve. *: When selecting a Super Unit, refer to Pressure-Flow rate characteristics and how to select a unit on Page 9. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

LOIL COOLING EQUIPMENT

LOIL COOLING EQUIPMENT OI COOING EQUIPENT Oil cooling unit, inverter controlled chiller (ir-cooled type) Product name KZ9 Series Circulating type oil cooling unit for machine tool spindles KZJ8 Series Immersion type oil cooling

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

Compact Ultra Low Temperature Chamber

Compact Ultra Low Temperature Chamber Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804 High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature

More information

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2002 Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Monitored Pneumatic Valves On Series Ported Manifold

Monitored Pneumatic Valves On Series Ported Manifold Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per EN 954-1 & AS4024.1 SIL 3 as per IEC 61508 Applications Include: Pneumatic Presses

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

ECO RICH. EHU SERIES Instruction Manual. Hybrid Hydraulic System

ECO RICH. EHU SERIES Instruction Manual. Hybrid Hydraulic System Hybrid Hydraulic System ECO RICH EHU SERIES Instruction Manual This instruction manual is based on these following types Eco Rich. As for MGF.NO. before them, there is some difference in operating manual

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

½ Monitored Pneumatic Valves On Series Ported Manifold

½ Monitored Pneumatic Valves On Series Ported Manifold ½ Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508 & EN ISO 13849-1 Applications

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

TAZUNA Unit: TAZ-111. PQ roid (Drill Identification System) User s manual. Important

TAZUNA Unit: TAZ-111. PQ roid (Drill Identification System) User s manual. Important TAZUNA Unit: TAZ-111 PQ roid (Drill Identification System) User s manual Important Read this manual thoroughly prior to installation of TAZUNA unit: TAZ-111. Follow each instruction given in this manual

More information

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1 SPLIT-TYPE AIR CONDITIONERS Revision D: Changing defrost finish temperature has been corrected (10-1.). Please void OBH516 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature

More information

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589) SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

Low Noise Type Hydraulically Driven Engine Cooling Fan System

Low Noise Type Hydraulically Driven Engine Cooling Fan System Kazuhiro Maruta Nobumi Yoshida Recently a hydraulically driven engine cooling fan is becoming a mainstream technology as one of the means to bring down the level of noises generated by construction equipment.

More information

CPVS PRODUCT DESCRIPTION

CPVS PRODUCT DESCRIPTION CPVS 20 30 PRODUCT DESCRIPTION The CHICAGO PNEUMATIC CPVS 20-30 compressor is a quiet, complete and ready-for-use unit for the production of compressed air for light and medium industrial applications.

More information

Example of Applications and Parameter Functions

Example of Applications and Parameter Functions PX-series digital temperature controller Example of Applications and Functions ECNO:1158 I. Example of Applications 1 Controlling both heating and cooling with a single controller Only one controller is

More information

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure. Refrigerant valves Valves for precise control and optimum energy efficiency in refrigeration systems Answers for infrastructure. MVL661.. MVS661..N and matching ASR valve insert The new generation MVL661..

More information

Introduction of Hanbell and

Introduction of Hanbell and Introduction of Hanbell and RC2 Series Screw Compressor Jude Chen April 2, 2007 Content 1.Hanbell Company Profile 2.Hanbell Machinery & Production 3.Basic Mechanism of Hanbell Screw Compressor 4.Hanbell

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

Screw Water Cooled Chiller SCW210

Screw Water Cooled Chiller SCW210 Screw Water Cooled Chiller SCW210 Nominal Cooling Capacity 185.1 to1480.8 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp) OIL-INJECTED ROTARY SCREW COMPRESSORS GA - VSD (- kw/-0 hp) Innovative Atlas Copco has turned the compressed air industry on its head by redesigning the conventional layout of a typical air compressor.

More information

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz

More information

MAC-A R410A Series Air cooled Modular Chiller

MAC-A R410A Series Air cooled Modular Chiller Catalogue MAC R410A 2011(60Hz) MAC-A R410A Series Air cooled Modular Chiller Model: Refrigerant: Co ling Capacity: MAC210A5 R410A 72kW Overview Based on the successful McQuay air-cooled modular chiller,

More information

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 60 z Table of contents 1. Product introduction 3 Features and benefits 3 Applications 3 2. Performance range 4 4 D single-head operation 5 D twin-head operation 6

More information

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Date: 2016.3.24 Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Symbol Amended Reason Pages Date Corrector Amendment No Approved by Checked by Drawn by Designed by UST-10LN Specification

More information

MD SERIES Instruction Manual

MD SERIES Instruction Manual IWAKI Magnetic Drive Pump MD SERIES Instruction Manual Read this manual before use of product Thank you for having selected the Iwaki Magnetic Drive Pump MD series. This manual deals with the correct handling

More information

Speed and Frequency Seite 1 von 7

Speed and Frequency Seite 1 von 7 Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.

More information

EC3-X33 Stand-alone Superheat Controller Technical Data

EC3-X33 Stand-alone Superheat Controller Technical Data Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud VUD Vac-U-Dry Vacuum Dehydrators The optimized balance between heat, vacuum, process design and an easy, user friendly operating system for removal of water and particulate from hydraulic and high viscosity

More information

With the world-renowned SIGMA PROFILE

With the world-renowned SIGMA PROFILE www.kaeser.com Rotary Screw Compressors BSD/CSD/CSDX T SFC Series With the world-renowned SIGMA PROFILE Free air delivery 0.87 to 16.10 m³/min, Pressures 5.5 to 15 11 What do you look for in a compressor

More information

EG Series Screw Air Compressors Life source of industries HP

EG Series Screw Air Compressors Life source of industries HP EG Series Screw Air Compressors Life source of industries 15-100 HP Elgi, established in 1960, designs and manufactures a wide range of compressors. The company has gained its reputation for design and

More information

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp) OIL-INJECTED ROTARY SCREW COMPRESSORS GA - VSD+ (- kw/- hp) Small compressor, big ideas Atlas Copco has turned the compressed air industry on its head by redesigning the conventional layout of a typical

More information

Supporting manufacturing shop floor with advanced liquid temperature control technologies

Supporting manufacturing shop floor with advanced liquid temperature control technologies Putting together Photograph provided by Kikuchi Seisakusho Co., Ltd. Supporting manufacturing shop floor with advanced liquid temperature control technologies Solution Solves customers needs Mission Supports

More information

Customized Industrial Products

Customized Industrial Products Customized Industrial Products Product Catalog Large Walk-in Type Drying Oven Large Size Autoclave Large Size Fine Oven Targeting Productivity Improvement Yamato offers customization of products based

More information

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation Compact design for personal use Ready to network with your computer. Introducing a new lineup of our Bench-top Type (& Humidity) Chamber Series. Our latest models achieve superb performance in a compact

More information

ECOPlus SERIES OF HIGH-PRESSURE METERING MACHINES

ECOPlus SERIES OF HIGH-PRESSURE METERING MACHINES ECOPlus SEIES OF HIGH-PESSUE METEING MACHINES The OMS ECOPlus series of high-pressure metering units provides the ideal solution for every PU application. eliability, ease of operation and attractive price-performance

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Erbium-Doped Fiber Amplifier (EDFA) - MW Series Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available

More information

RAYCHEM NGC-30 COMPONENTS

RAYCHEM NGC-30 COMPONENTS PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

Series 45 Pumps Fan Drive Control (FDC)

Series 45 Pumps Fan Drive Control (FDC) Electrical Installation Series 45 Pumps Fan Drive Control (FDC) powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev July 2016 First edition 0101 2 Danfoss July 2016 BC00000371en-US0101

More information

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to 1.99 kw Centrifugal compressor with magnetic levitation This is a miniaturized, highly innovative

More information

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp) Atlas Copco Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp) Extreme savings No idling time Silent operation Small footprint The new revolutionary compressor from Atlas Copco

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5

More information

½ Monitored Pneumatic Valve Patented Technology

½ Monitored Pneumatic Valve Patented Technology ½ Monitored Pneumatic Valve Patented Technology PBM4-S (Valve only air service equipment not included) SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has

More information

Technical description

Technical description Rail profile grinding machine NRG Technical description Nencki Ltd Railway Technology Gaswerkstrasse 27 4901 Langenthal Switzerland Tel. +41 62 919 93 93 Fax +41 62 919 93 90 railway@nencki.ch www.nencki.ch

More information

Water cooled VRV IV W-series

Water cooled VRV IV W-series Water cooled VRV IV W-series Ideal for high rise buildings, using water as heat source Unified range for heat pump & heat recovery and standard & geothermal series 22 Indoor units VRV type indoor units

More information

Pre-programmed room controller with communication

Pre-programmed room controller with communication revision 02 2016 RC-C3 Pre-programmed room controller with communication RC-C3 is a complete pre-programmed room controller from the Regio Midi series intended to control heating and cooling in a zone

More information

technical data Fan coil unit FWB small duct unit

technical data Fan coil unit FWB small duct unit technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------

More information

TECHNICAL NOTICE GH/GHO/GAE V

TECHNICAL NOTICE GH/GHO/GAE V TECHNICAL NOTICE GH/GHO/GAE V1.0-02.14 INDUSTRIAL COOLING UNITS Identification Marksa SA Industrial cooling 39, avenue du Technicum CH-2400 Le Locle Version Date Modifications 1.0 14.02.14 First edition

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers 687 Optical Touch Switch SW-1 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Conforming to OSHA / ANSI Listing MEASURE panasonic.net/id/pidsx/global

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL No. OCH468 REVISED EDITI-A HFC utilized R4A June 2 [Model name] MXZ-8B48NA PAC-AKA5BC PAC-AKA3BC (Indispensable

More information

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions

More information

Vacuum generators VADM/VADMI

Vacuum generators VADM/VADMI Key features Product overview Vacuum generators All Festo vacuum generators have a single-stage design and operate according to the Venturi principle. The product series described below have been designed

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - Nominal Cooling Capacity Range 112 kw to 1,080 kw at 50Hz 32 USRT to 307 USRT at 50Hz 96,320 kcal/h to 928,800 kcal/h at 50Hz 382,000 Btu/h to 3,685,000

More information

Scroll Water Cooled Chiller

Scroll Water Cooled Chiller Scroll Water Cooled Chiller SRW145 Nominal Cooling Capacity 77 to 1232 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

SELF-PRIMING JET PUMPS

SELF-PRIMING JET PUMPS SS Anti-Rust SS Shaft Copper & Cold-rolled SELF-PRIMING JET PUMPS CONTENTS 1. Applications.... Model Description.... Technical Data... 4. Implementation Standards... 5. Safety Precautions... 6. Product

More information

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52 Error Codes: Outdoor Units Error Codes: Outdoor Units Part. What Is in This Chapter? Introduction Overview In the first stage of the troubleshooting sequence, it is important to correctly interpret the

More information

General Specifications

General Specifications General Specifications Model DM8 Vibration Type Liquid Density Meter Overview In 1967, YOKOGAWA developed the Model VD6 Vibration Type Liquid Density Meter in response to user requests for an online density

More information

CXAV / CGAV. Trane Module Chiller. Industry top class efficiency and reliability

CXAV / CGAV. Trane Module Chiller. Industry top class efficiency and reliability CXAV / CGAV Trane Module Industry top class efficiency and reliability Trane Module Adopts resin coated blue fins Design registration n pending High-efficiency, high-durability and space-saving Resin coated

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

Compact design for personal use Ready to network with your computer.

Compact design for personal use Ready to network with your computer. Compact design for personal use Ready to network with your computer. Introducing a new lineup of our Bench-top Type (& Humidity) Chamber Series. Our latest models achieve superb performance in a compact

More information

4.Metering Pumps CONSTRUCTIONS. CR-N Series CRA-N Series: servo control model. CRP-N Series

4.Metering Pumps CONSTRUCTIONS. CR-N Series CRA-N Series: servo control model. CRP-N Series 4.Metering Pumps ELEPON FEEDER CR-N and CRM Series are designed as the direct-motion diaphragm injection pumps as safe and multipurpose pumps and also low-cast pumps. These pumps are used as the injection

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

P4200PM / P5000PM Remote Air Dryer User s Guide

P4200PM / P5000PM Remote Air Dryer User s Guide P4200PM / P5000PM Remote Air Dryer User s Guide 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS P4200PM / P5000PM Air Dryer! We here at PUREGAS are very proud of our products

More information

Rotary type Oil-free Air Compressor General Catalogue. Oil-free Scroll Air Compressor Oil-free Claw Air Compressor

Rotary type Oil-free Air Compressor General Catalogue. Oil-free Scroll Air Compressor Oil-free Claw Air Compressor Rotary type Oilfree Air Compressor General Catalogue Oilfree Scroll Air Compressor Oilfree Claw Air Compressor Quiet & Compact, Simple Air Quietness Easy operation Cleanness The scroll mechanism ensures

More information

. Creating Maximum Comfort

. Creating Maximum Comfort P P r o d u c t E X P L A N A T I O N M M a i n F E A T U R E S AA. Creating Maximum Comfort 1 Inverter technology The linear VRV system makes use of a variable Proportional Integral (PI) control system

More information

Exciting Swiss temperature control technology, distributed in North America exclusively by...

Exciting Swiss temperature control technology, distributed in North America exclusively by... Exciting Swiss temperature control technology, distributed in North America exclusively by... TM North America Frigel North America, Inc. 150 Prairie Lake Rd, Unit A East Dundee, IL. 60118 USA Tel (847)

More information

TH450A-CRB TH550A-CRB THP550-CRB/TS3000

TH450A-CRB TH550A-CRB THP550-CRB/TS3000 TH450A-CRB TH550A-CRB THP550-CRB/TS3000 INSTRUCTION MANUAL CLEAN TYPE INDUSTRIAL ROBOT SPECIFICATIONS Notice Make sure that this instruction manual is delivered to the final user of Toshiba Machine s industrial

More information

AnyWireASLINK System Products Guide

AnyWireASLINK System Products Guide READER/WRITER MADE IN JAPAN System Products Guide S-K1117 -M -3012 is a registered trademark of OMRON Corporation. [Notes on Safety] Precautions that must be observed in order to use this system safely

More information

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

ProMinent ProMus Hydraulic Diaphragm Metering Pumps ProMinent ProMus ProMinent ProMus Description: The ProMus is a motor driven metering pump with a hydraulically actuated diaphragm. The drive case and the hydraulic unit are filled with a liquid that functions

More information

Modular standard power units

Modular standard power units Modular standard power units RE 51013/04.06 Replaces: 11.02 1/26 Type ABSKG Tank capacity 20, 40 and 60 litres abskg Table of contents Contents Page Features 1 Ordering code 2 and 3 Control variants 3

More information

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax Speedy and Compact High-Precision Thermal Tests Made Possible This thermal-plate system has been developed to enhance heat conductivity to the specimen. When the specimen is placed on the thermal plate,

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the

More information