Indoor Air Quality. For assured. Double Skin Air Handling Units
|
|
- Aldous Boone
- 5 years ago
- Views:
Transcription
1 Double Skin Air Handling Units INTL-31-OCT 06-R0 CI For assured Indoor Air Quality. For more information, please contact BLUE STAR LIMITED, International Division, Band Box House, 4th Floor, Dr. Annie Besant Road, Worli, Mumbai India. Tel: Fax: Visit us at: or exports@bluestarindia.com 12 1
2 Blue Star is India s leading airconditioning Company, with over 6 decades of experience in providing expert cooling solutions. On offer are Double Skin Air Handling Cu Tubes Units that are developed and powered with innovative technology to provide end customers with excellent and optimized solutions. DIDW Centrifugal Following are some of the options that you can Forward Curved Fan Sandtrap choose from: Louvers Bag Filter Horizontal Floor Mounted Vertical Floor Mounted Ceiling Suspended Certificates Flexible Canvas Connection Base Frame Ultraviolet Light Aluminium Anodized Frame Anti-Corrosive Hydrophilic Coated Fins 2 Pre Filter 3
3 Product Specifications Coils Quality Assurance Primarily coils are designed for chilled water and direct expansion applications, manufactured AHUs comply with the standards mentioned below: The panel is made of Sandwich construction of 25 mm or 46 mm, injected with CFC free, from ½ OD copper tubes of staggered configuration and counter flow design. Drain Pan ISO on Quality Management System. EN 1886, EN on Mechanical and Performance characteristics. i. Casing Strength: Class 2A ii. Casing Air Leakage: Class A iii. Thermal Transmittance: Class T2 iv. Thermal Bridging Factor: Class TB2 AMCA 210 on Fans Air Flow performance and AMCA 300 Sound performance Casing Rigid frame work construction made of extruded hollow aluminium anodized profile with nylon fiber glass corner joints and reinforced internally. Optional thermal bridge frame work for fresh air application and outdoor installation ensures elimination of condensation phenomenon on frame work. R141b blended, polyurethane foam insulation having density of 40 Kg / m³ and thermal conductivity of W/m K. This provides excellent thermal insulation and sound attenuation properties. The casing panels (Inner and Outer) are constructed of zinc coated steel sheets. Options available on sheet specifications are: 0.6/0.8/1.0/1.2 mm steel sheet coated with 220 g/m² galvanized zinc (Zn) and 3% chromate. 0.6/0.8/1.0/1.2 mm steel sheet coated with 120 g/m² galvanized zinc (Zn) and pure polyester pre-painted of coating thickness 25 µm for corrosion protection. 0.8/1.0/1.2 mm aluminium sheet. 0.6/0.8 mm stainless steel sheet of grade SS-304/SS-316. The panels are removable and are fixed to the frame with self-tapping screws. Labyrinth type gasket sealing between frame and panel eliminates possibility of any air leakage. The entire unit is supported on full perimeter base frame constructed from heavy duty galvanized steel sheet. The Free Flow Fins configuration combines a mild ripple with die formed directional guide channels. These create a turbulent wiping action in the normally dead area behind the tubes. And thereby prolong the contact with cooling surface. Such advance engineering techniques allow AHUs to improve the heat transfer capability and ensure the optimum balance between a high heat transfer coefficient and a minimum pressure drop. Various circuiting methods provide more flexibility, wider selection, and unexcelled performance optimization. Mechanical expansion of tubes assure tight bonding between tubes and fins for better heat transfer. The full channel galvanized steel frame and intermediate support provides rigid frame structure. The headers are heavy section with seamless copper tubing. The end connection is made in steel pipe for a welded joint. One drain and one vent fitting are conveniently located on inlet and outlet connection. Complete coils are factory pressure tested at 325 psig compressed air under water. Coils are Drain pan with wider width and differential slope ensures complete drainage of condensate. Typically the drain pan is fabricated from 0.8 mm thick stainless steel grade SS-304 insulated with 10.0 mm close cell, cross linked, irradiated, fire retardant grade polyethylene material. Intermediate tray is provided for stacked coils to collect the condensate from the top coil. Coils with hydrophilic coating are available as an option. Pre-coated fins have distinct advantage over conventional fins because of its water shedding properties, corrosion resistance and excellent UV resistance. These properties increase coil efficiency and enhance cooling capacity. For clear room application, the optional full channel frame constructed of stainless steel SS 304 grade is available. designed for operation up to 250 psig design working pressure at 300 F. 4 5
4 Fans Filters Fans used are Kruger make, AMCA certified, The filter comprises of high quality synthetic filter energy efficient. media from FilterAir. The media is thermally All wheels are statically, dynamically and trim balanced to ISO 1940 and AMCA 204/3 G2.5 standard. The operating limit of each fan type is designed to meet the requirement of class I, II and III limit as defined in AMCA standard Bearings used are either deep groove ball bearing type with an adaptor sleeve, or spherical roller bearing type at both sides for different duty applications. Housings are fabricated from galvanized sheet steel and shaft from C45 carbon steel. Various options available on types of fans used in the air handling unit are: Fire retardant, Flexible connectors are provided between the fan discharge and main casing. Motor and Drive Package Motors used are energy efficient, totally enclosed fan cooled (TEFC) type, with IP 55 protection, Class F insulation, three phase, 50 Hz, 415 V, Squirrel cage induction motor. Dual duty, Taper lock, Split bush, are used to eliminate the re-boring and keyway problems and convenience in maintenance. Matching Wedge V belts are used for high power transmission. Various options are made available to meet the specific, customized requirements: bonded with progressive density to have high dust holding capacity and low initial pressure drop. The media is certified as self extinguishing class 2 as per UL 900. The filters efficiency is tested in accordance with ASHRAE standards. Filter media is stamped with filter class as a proof of originality. Pre-Filters The media in pleated construction is housed in galvanized/aluminium cassette type frame supported with aluminium mesh on air leaving side. Filters efficiency conforms to G3 grade, 90% down to 10 micron as per EN-779 standard. Secondary Bag Filters The synthetic media consists of strategically layered and blended melt-blown polypropylene fibers fastened to a non-shed, high density polypropylene backing. Vertical separators are incorporated into each pocket to effectively channel air throughout the media to prevent excessive turbulence and maintaining low pressure drop. F7 & F9 Filters efficiency conforms to 98% down to 3 micron and 99.9% down to 3 micron respectively as per EN-779 standard. HEPA Filters Ideal design to be used in hospitals, pharmaceutical, electronics and clean room applications. DIDW, Centrifugal Fan with Forward Curve Wheel. DIDW, Centrifugal Fan with Backward Curve Wheel. DIDW, Centrifugal Fan with Backward Curve Air Foil Wheel. Plenum (Plug) Fan with Backward Curve Wheel. Dual Speed Flame Proof Construction Variable Pitch Pulley The complete fan and motor assembly is placed on separate aluminium extruded base frame, isolated from the main unit with rubber mounts / spring isolators. Preliminary Bag Filters The pockets are housed in galvanized/aluminium flange type frame. These pockets are welded at edges into a rigid and aerodynamic shape to reduce the pressure drop. Special welded spacers ensure full media utilization. Filters efficiency conforms to F5 grade, 99% down to 5 micron as per EN-779 standard. The filter features high efficiency micro-glass paper pleated to form compact media pack. Filters are scanned for leak-free construction. The filter utilizes a continuous sheet of wet-laid micro-fiber media that is deep pleated and can operate in applications with 100% humidity. Super Flow, H13 Filters efficiency conforms to % down to 0.3 micron particle size at rated flow as per EN 1822 standard. 6 7
5 Dampers VFD Variable Frequency Drive The volume control dampers have been Fully dedicated to HVAC applications, advanced designed to provide positive control of air within the airconditioning system. Dampers are constructed from high quality aerofoil design aluminium / galvanized extrusion and suitable for flanged Heat Recovery Wheel Current ASHRAE standard recommends the 20 ~ 30 CFM per person in a conditioned room to avoid Sick Building Syndrome and maintain the High Indoor Air Quality. variable speed technology is used to bring down energy and maintenance cost. Drive includes an RFI filter, DC link coils and an in-built 2 zone PID controller. The detachable Local Control Panel makes it easy to copy programming instructions. It Following are the various parameters which can be controlled efficiently: Outside air & air mixture damper, with free cooling, free heating and enthalpy control Intake & supply fan, with two steps or inverter connection within square or rectangular shape. Blades are mainly pivoted on PVC bushes and operate through PVC gear system which is fully enclosed with the damper frame. A wide range of control options are available and include motorized and manual operation Electric Heater U shaped tubular finned heaters are used to increase surface area for effective heating. These heaters come with mounting clamp and insulated with heat shrinkable sleeve for electrical connections. Watt density of heaters is maintained at 5 watts / cm². Stale air from the airconditioned space is exhausted through one half of the heat wheel while fresh air is drawn through the other half of the wheel in a counter flow pattern thereby achieving energy recovery. Also managing savings in operation cost. Heat recovery wheels use custom made metallic honey comb matrix coated with Molecular Sieve dessicant. The heat recovery wheels used are suitable at 80% equal and both Sensible and Latent heat recovery at 700 FPM face air velocity. The rotary heat exchangers are provided with purge section to reduce the penetration of exhaust air to supply air. Non contact labyrinth seals are placed on the rotors perimeter and dividing line to provide additional protection against air leakages. has several read outs to choose from with crystal sharp display. It also has a true Hand-Off-Auto function with local and remote control. In new installation, a payback time of less than one year can be achieved when compared to constant volume systems. Intelligent Controller The Intelligent controller is a highly advanced, user friendly controller with a micro processor based program which comes with an in-built display. The Blue Star solutions for Air Handling Unit market completes the range by offering all the components like electrical panel, pressure, temperature, humidity, air quality probes, differential pressure switch, flow switch, actuators, etc required for the control system and application to meet varied customer requirements. control Water heating coil and electric heaters, with preheating management Water cooling coil Direct expansion with condenser control Direct expansion with three On/Off steps Cross-flow, rotary and double coil heat recovery unit Supply & return air filter Adiabatic/Steam humidification with On/Off or modulating control Built-in daily/weekly timer All models are network connection enabled, using RS 485 port & MODBUS protocol Heat wheels used are certified under ARI 1060 certification program. A total of 24 different pre-configured systems are available and can be selected by setting just one parameter. 8 9
6 Technical Specifications Fresh Air Intake Section with Sand Trap Louver & Pre-Filters Mixing Box Section with Pre-Filters & RA / FA Dampers Mixing Box Section with Pre-Filters & RA / EA / BD Dampers Filters Pre-Filter Section Combination Filter Section - Pre + Fine / Bag 300 mm Deep Combination Filter Section - Pre + Bag 600 mm Deep Fine / Bag Filter Section mm Deep (with Access Door) Bag Filter Section mm Deep (with Access Door) HEPA Filter Section mm Thk. (with Access Door) Cooling Coil Coil Section (1-6 Rows) Coil Section (8 Rows) Coil Section (2 - RD - Heating & 6 - RD - Cooling) Coil Section (2 - RD - Heating & 8 RD - Cooling) Electric Heater Section Droplet Eliminators (4 Pass) Heat Recovery Wheel Section Supply Air Plenum Section Fan Section - Horizontal & Vertical Discharge Fan Model (Kruger) Width Height Width Height Air Quantity AHU 2.54 m/s AHU Dimensions with 25 AHU Dimensions with 46 Section Length Filter Area Section Length Coil Area Section Length Fan Dia. mm thk. PUF Panels mm thk. PUF Panels CMH mm mm mm mm mm mm mm Sq. mtr. mm mm mm mm mm mm Sq. mtr. mm mm mm mm mm mm mm mm mm mm E E E E E E E E E E E Notes: 1. AHU with single Modular unit. 2. Please add 100 mm of extrusion length in each module. 3. Add 100 mm in the AHU height for Base channel. 4. Standard empty sections are available in sizes : 180, 319, 458, 597, 736, 875, 1014 & 1153 mm. * Specifications are subject to change due to continuous product development
Double Skin Air Handling Units
Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering
More informationDouble Skin Air Handling Units
Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering
More informationDouble Skin Air Handling Units
Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering
More informationAIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationDouble Skin Casing Air Handling Units
Double Skin Casing Air Handling Units Double wall with 25 mm insulation Modular design for clean process application flexibility all the requirements 2,000 40,000 CFM AUTUMN Air Handling Units incorporate
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationGUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS
S FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS VAYHAN AIR CONTROLS PVT. LTD. G-1, Park View Residency, Patwari Enclave Gandhi Nagar (IDPL), Hyderabad 500 037. INDIA Phone: +91-40-2372
More informationCenteral Station Air Handling Unit
Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof
More informationAIR HANDLING UNITS. Revision AG 16-07
AIR HANDLING UNITS UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products
More informationA. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.
SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More information1.1 This section applies to air handling units for HVAC Systems.
AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling
More information39HQM Central Station Air Handling Units AiroVison Guide Specifications
39HQM Central Station Air Handling Units AiroVison Guide Specifications Page 1 AiroVision Guide specifications 39HQM Central Station Air Handler Units Size Range: 936 to 81,360 Nominal m3/h 64 different
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationHIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%
Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and
More informationAIR HANDLER SPECIFICATION
AIR HANDLER SPECIFICATION Air Handlers AH-1 through 5 The following air handlers will be supplied: AH-1 FX15-4842 Series 5700 CFM AH-2 FX15-4236 Series 3990 CFM AH-3 FX15-3633 Series 2570 CFM AH-4 FX15-3330
More informationSECTION AIR HANDLING UNIT
SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR
More informationAIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.
SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving
More informationUNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013
SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.
More informationTYPICAL CPA SPECIFICATIONS
TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationAIR HANDLING UNIT AWAL GULF AIR CONDITIONING & REFRIGERATION PVT. LTD.
AIR HANDLING UNIT AWAL GULF AIR CONDITIONING & REFRIGERATION PVT. LTD. th No- A44/a 24, 6 Street, A Block,Anna Nagar East, Chennai-600102, Tamil Nadu, india +91 44 26208566 marketingindia@awalgulf.com,
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationA. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.
15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution
More informationMODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC
MODUAR AIR HANDING UNIT Models: FAC / FMC / FBC Contents Product Nomenclature... 2 Features... 4 Engineering Specifications... 13 Cooling Coil Performance Chart... 13 Heating Coil Performance Chart...
More informationUNIVERSITY OF MISSOURI Central Station Air-Handling Units March
GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,
More informationFAN COIL UNITS. The optimal solution for limited space
FAN COIL UNITS The optimal solution for limited space CLEAN AIR SINCE 1963 Euroclima is a company with extensive international operations with four manufacturing facilities in Italy, Austria and India
More informationSeries. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:
RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons
More informationSeries PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:
RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationAir Handling Units. Real HVACR people who understand your needs.
Air Handling Units Real HVACR people who understand your needs. Copyright HC Heat-Exchangers (PTY) Ltd. 1 Copyright HC Heat-Exchangers (PTY) Ltd. 2 About the HC AHU range HC Heat-Exchangers rich engineering
More informationSECTION AIR DUCT ACCESSORIES
SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control
More informationComplete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A
Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels
More informationAIR HANDLING UNITS MANDÍK
AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...
More informationSubmittal Data Performance Data Electrical Data
ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:
More informationwe make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)
we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established
More information13 HYGENIC AIR HANDLING UNITS
39HQM INDEX 1 GENERAL 3 2 STANDARDS 4 2.1 Mechanical Strength 4 2.2 Casing air leakage 4 2.3 Filter bypass leakage 5 2.4 Thermal transmission 5 2.5 Thermal bridges 6 2.6 Acoustic casing insulation 6 3
More informationLOW STATIC HYDRONIC DUCTED UNIT
LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity
More informationA. This Section includes air-handling units with coils for indoor installations.
SECTION 237313 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes air-handling units with coils for indoor installations. 1.2 SUBMITTALS A. Product Data: For each type of indoor air-handling unit
More informationBulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications
Bulletin C6200 MAY 20 3 Buffalo Air Handling Big Buffalo Custom Applications Buffalo Air Handling Big Buffalo The historic strength of Buffalo Air Handling is the custom designed air handling equipment
More informationChilled Water DOAS Fan Powered Terminal Units
Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner
More informationAir handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation
Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique
More informationWater Chiller Solutions. A solution to every water cooling need.
Water Chiller Solutions A solution to every water cooling need. During the harsh summers of Middle East, the ambient temperature is very high and it can go up to as much as 52 o C. Naturally, in such conditions,
More informationDARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15856 MODULAR AIR HANDLING UNITS PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. NFPA Compliance: Modular air handling units and components shall be designed, fabricated, and installed in compliance
More informationDIVISION 15 MECHANICAL
DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with
More informationAir handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation
Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique
More informationModular Air Handling Unit
MAHUs are modular so that they have the flexibility to add components as required. The 3rd generation Midea MAHU adapts unitary structure design, more outstanding cold-bridge free performance, lower air
More information39G Air Handling Unit
39G Air Handling Unit Air flow: 2000 ~ 60000 m³/h The Manufacturer reserves the right to change any produt specifications without prior notices Version: Supersede: Effective Date: CAT_39G_E-1307_02 CAT_39G_E-1205_01
More informationVERTICAL FAN COIL UNITS
VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote
More informationCLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements
Excellent quality / price ratio Very short delivery time Double wall 50 mm insulation Complete range meeting all the tertiary requirements Air flow : 000 to 7 000 m 3 /h DESCRIPTION Casing Double wall
More informationSeasonMaker ThinLine Fan-coil Units
Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute
More informationAIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters
237300 AIR HANDLING PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230530 Clean Steam Generation B. Section 230900 Building Automation and Control System Guidelines C. Section 234100 Air Cleaning Devices
More informationEasdale International INFINITY
Easdale International INFINITY Air flow from 800 to 0.000 m 3 /h APPLIED SYSTEM AIR HANDLING UNITS AHU N : 0.0.502 Range: Easdale International www.eurovent-certification.com www.certiflash.com Engineered
More informationMLR SERIES MODULAR AIR HANDLING UNITS
MODULAR AIR HANDLING UNITS General Information MAINSTREAM About Mainstream Mainstream offers a diverse line of custom air handling units, as well as heat transfer coils and other components required for
More informationVERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System
VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically
More informationAdvance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units
Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium
More informationIf a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.
Air handling units Aesthetic Not to add significantly to the existing ambient noise levels. Functional requirements If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally
More informationA. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.
Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section
More informationUniversity of Delaware
University Contact: Energy & Engineering Group (302) 831-1744 SECTION 23 73 00_AIR HANDLING UNITS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Modular custom & semi-custom built indoor air handling
More informationAll side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.
All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing
More informationHigh Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)
High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust
More informationPharmaceutical Facility Design
PhEn-602 Pharmaceutical Facility Design J. Manfredi Notes 9A PhEn-602 J. Manfredi 1 Primary & Secondary HVAC units Primary Primary air handling unit arrangement: One unit is responsible for all of the
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 08:50:16 AM Job Name: EarthWise Modular Climate Changer Full Spec Location: Any Town, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SUBMITTALS Submittals
More informationSeasonMaker ThinLine Fan-coil Units
Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute
More informationDUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES
DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators
More informationVERSO Air Handling Units
Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system
More informationRosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS
10 Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 2 INDEX Page Description - Introduction -Application - Data... 2 Typical Installation... 3 Sound performance... 3-6 Dimensional
More informationTHE ULTIMATE ROOFTOP SOLUTION
Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly
More informationSpecification Data. General:
Specification Data General: Zone Units (ACU s) will be draw through vertical type having double skin construction. All Zone Units will have all necessary components such as control valves and motors to
More informationPINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION
ENERGY EFFICIENT DEHUMIDIFICATION PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM Provides a very high degree of latent cooling using only a minimal amount of conventional cooling input Substantial energy
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationR22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH
R22 IR COOLED HIGH STTIC DUCTED SPLIT SYSTEM Single & Double Skin Evaporator Units Cooling Capacity : 80 to 750 MBH Innovative Outstanding DESIGN & PERFORMNCE IR COOLED CONDENSING UNITS SYSTEM FETURES
More informationSeries 2 FS 100 HM Q S AH D on innovative. a full green. meeting. line features. Page No Introduction a high unit is. Air Handling Units
INTRODUCTION For more than 100 years, DunhamBush has focused on innovative product development. Today, we provide a full portfolio of HVAC/R products from Fan Coil Units to large centrifugal chillers as
More informationEnjoy the Delighting Comfort Brought by High Air Quality
Enjoy the Delighting Comfort Brought by High Air Quality Untes air handling units meet the required level of indoor air quality while maintaining the humidity and the temperature under control. They ensure
More informationHood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL
The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize
More informationTECAM S.A. Environmental Technology
TECAM S.A. Environmental Technology AIR HANDLING UNITS Heavy Duty 1000 50000 CFM 3 Ton 90 Ton 3AHB / 3ADB / 3ADBT Air Handling Units Manufacturing of Equipment for Air Conditioning and Refrigeration Registration
More informationA. Codes and Standards that are Standard at the University:
PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The
More informationSECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.
Page 237323-1 SECTION 237323 - For large systems, 50,000 cfm or more. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationSECTION (15820) - AIR DUCT ACCESSORIES
PART 1 GENERAL 1.01 SUMMARY A. Section includes: SECTION 23 33 00 (15820) - AIR DUCT ACCESSORIES 1. Manual-Volume Dampers 2. Fire Dampers 3. Turning Vanes 4. Duct-Mounted Access Doors 5. Flexible Connectors
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More informationENVIRO UNIT ENGINEERING MANUAL KES SERIES
ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units
More informationDIVISION 23 - HVAC HVAC Air Distribution
PART 1 - GENERAL 1.01 GENERAL CRITERIA A. General Design Criteria 1. System standards require that buildings be fully ducted (supply, exhaust and return air). 2. Provide positive exhaust ventilation for
More informationCOOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS
COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS THE DAWN OF A NEW ERA Political and ecological pressures over the past few years, have led to a change of emphasis in the design of fully air-conditioned
More informationA. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.
Page 238219-1 SECTION 238219 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM
SECTION 23 81 06 - PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. This Section includes equipment types that contain all the components of the refrigeration process within
More informationHi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE
Hi-Pres Self Contained A/C Unit TYPE SCU-C & SCU-W Product specifications HI-PRES MARINE & OFFSHORE Contents Introduction..................... 2 Type SCU-W.......................... 2 Type SCU-C...........................
More informationProduct catalogue Air handling units. Easy and flexible solutions for any ventilation requirements
Product catalogue 2018 Air handling units Easy and flexible solutions for any ventilation requirements ARGUE CARDS Daikin air handling units Why choose Daikin air handling units? Maximum energy efficiency
More informationGeneral Catalogue. FORM SSI - G.C (94)
FORM SSI - G.C (94) www.ssi.co.ir General Catalogue INDEX 09CDF 16DNS 16DES 16JBP 16JBP Air Cooled Condenser Air Cooled Condenser Absorption Chiller Double Effect Direct Fired Absorption Chiller Double
More informationHeat Recovery Units. Heat Recovery 1
Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air
More informationWE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL
PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT
More informationA. Section Common Motor Requirements for HVAC Equipment: Fan motors.
SECTION 233516 - ENGINE EXHAUST SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Exhaust fans. B. Ductwork and duct fittings. C. Inlet fittings. D. Accessories. E. Carbon monoxide detectors. 1.2 RELATED
More informationYMA Custom Air Handling Units
airside products YMA Custom Air Handling Units by johnson controls Air Volume Range 0.25 m 3 /s to 60 m 3 /s YMA Custom Air Handling Units Air Volume Range 0.25 m 3 /s to 60 m 3 /s The YMA family of air
More informationCultivator & Hybrid Cultivator
Cultivator & Hybrid Cultivator Precision Temperature & Humidity Packaged Unit INTRODUCTION The Cultivator Series package unit is the industry s MOST ENERGY EFFICIENT and HIGHEST capacity dehumidifier on
More informationSPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS
SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification
More informationDIVISION 23 - HVAC HVAC Air Distribution
PART 1 - GENERAL 1.01 GENERAL CRITERIA A. General Design Criteria 1. System standards require that buildings be fully ducted (supply, exhaust and return air). 2. Provide positive exhaust ventilation for
More informationCompact. Efficient. TROX.
Compact. Efficient. TROX. The art of handling air TROX understands the art of handling air like no other company. Since its foundation in 1951, TROX has been developing and manufacturing sophisticated
More informationVERSO Air Handling Units
VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P
More informationCLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS
7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor
More informationEnergy Recovery with Cooling and Heating
Energy Recovery with Cooling and Heating VersiVent - Model VER Commercial Institutional 2,000-10,000 cfm 3.0 in. wg external static pressure Configurable September 2008 Page The VersiVent Header Model
More information