1 I nf r ar edcab netheat er MODEL :RC9200I T CAUT I ON-F ORYOURSAF ET Y dooruseonl y WARNI NG:ForOut mpr oper nst al l at on,adj ust ment,al t er at on,ser v ceorma nt enance WARNI NG:I cancausepr oper t ydamage, nj ur yordeat h.readt he nst al l at on,oper at ngandma nt anance nst r uct onst hor oughl ybef or e nst al l ngorser v c ngt h sequ pment. WARNI NG Donotst or eorusegasol neorot herf l ammabl evapor sandl qu d nv c n t yoft h sorany ot herappl ance. AnLPcyl ndernotconnect edf oruseshal lnotbest or ed nt hev c n t yoft h sorany ot herappl ance DANGER I fyousmel lgas: 1. Shutof fgast ot heappl ance. 2. Ext ngu shanyopenf l ame. 3. I fodorcont nues,keepawayf r om t heappl anceand mmed at l ycal lyourgas suppl erorf r edepar t ment. The nst al l ershoul dl eavet he nst r uct onsw t ht heconsumer Theconsumershoul dr et a nt he nst r uct onsf orf ut ur er ef er ence REECONNORT HAMERI CA 2515L I BERT YAVE. 1S TF L OOR PI T T S BURGH,PA WWW. T HERMABLAST ER. COM I NF RARED

2 TABLE OF CONTENTS About Us... 1 Product Specfcatons 1 Important Safety Informaton.2 Product Features...3 Preparng for Installaton...4 Installaton...4 Ar for Combuston and Ventlaton...7 Unt Operaton....8 Care and Mantenance...10 Troubleshootng...11 Illustrated Parts...15 Parts Lst...16 Servce Schedule, Regstraton and Contact Informaton...17 ABOUT US We at Reecon strve to produce the hghest qualty Thermablaster heaters to warm our customers. We feel that a heater should look as good as t operates and work wthout a fuss. That s why we have developed our patent pendng dual fuel heatng system, whch allows the use of ether lqud propane or natural gas for some of our most popular products, wthout requrng any adjustments. Our product lnes consst of vent free gas wall heaters, a drect vent gas wall heater lne, kerosene and propane forced ar heaters, electrc ndustral heaters, freplace sets, as well as outdoor heatng products. Through our nnovatve product desgn and customer frst mentalty, we strve to provde the best heaters for all needs, at a prce that won t break the bank. PRODUCT SPECIFICATIONS Model BTU Gas Type Pressure Regulator Settng Maxmum Inlet Gas Supply Pressure Ignton Heat Settng RC9200IT 32,000 BTU (9.4Kw) Propane 11 W.C. 11 W.C. Electrc Pezo 2 Stage (H/Low) Verson 2.0A June

3 IMPORTANT SAFETY INFORMATION IMPORTANT: Read ths owner s manual carefully and completely before tryng to assemble, operate, or servce ths heater. Improper use of ths heater can cause serous njury or death from burns, fre, exploson, electrcal shock, and carbon monoxde posonng. Only a qualfed nstaller, servce agent, or local gas suppler may nstall and servce ths product. WARNING: Do not store or use gasolne or other flammable vapors and lquds n the vcnty of ths or any other applance. CARBON MONOXIDE POISONING: Early sgns of carbon monoxde posonng resemble the flu wth headache, dzzness and/or nausea. If you have these sgns, heater may not be workng properly. Get fresh ar at once! Have heater servced. Some people - pregnant women, persons wth heart or lung dsease, anema, those under the nfluence of alcohol, those at hgh alttude - are more affected by carbon monoxde than others. WARNING: Any change to ths heater or ts controls can be dangerous. WARNING: Do not use any accessores not approved for use wth ths heater. WARNING: Carefully supervse young chldren when they are n the area wth the heater. WARNING: Make sure both grll guards are n place before runnng the heater. (see dagram page 4) WARNING: Keep the applance area clear and free from combustble materals, gasolne, and other flammable vapors and lquds. WARNING: Due to hgh temperatures, the applance should be located out of traffc and away from furnture and draperes. WARNING: Certan materals or tems, when stored under the heater, wll be subjected to radant heat and could be serously damaged. WARNING: Heater becomes very hot when runnng. Keep chldren and adults away from hot surfaces to avod burns or clothng gnton. Heater wll reman hot for a tme after shutoff. Allow surfaces to cool before touchng. WARNING: Do not place clothng or other flammable materal on or near the applance. Never place any objects n the heater. WARNING: Falure to keep the prmary ar openng(s) of the burn(s) clean may result n sootng and property damage. WARNING: Do not allow fans to blow drectly nto the heater. Avod any drafts that alter burner flame patterns. Do not use n wndy condtons. 2

4 WARNING: Do not use a blower nsert, heat exchanger nsert or other accessory not approved for use wth ths heater. WARNING: Falure to poston the parts n accordance wth these dagrams or falure use only parts specfcally approved wth ths heater may result n property damage or personal njury. Ths heater needs fresh ar ventlaton to run properly. Ths heater has an Oxygen Depleton Sensng (ODS) safety shutoff system. The ODS shuts down the heater f not enough fresh ar s avalable. See Ar for Combuston and Ventlaton. DO NOT RUN HEATER: Where flammable lquds or vapors are used or stored or under dusty condtons. Always run heater wth control knob locked postons. Never set control knob between locked postons. Poor combuston and hgher levels of carbon monoxde may result. Perodc vsual check of plot and burner flame are necessary for proper operaton. QUALIFIED INSTALLING AGENCY Only a qualfed agency should nstall and replace gas ppng, gas utlzaton equpment or accessores, and repar and equpment servcng. The term qualfed agency means any ndvdual, frm, corporaton, or company that ether n person or through a representatve s engaged n and s responsble for: a) Installng, testng, or replacng gas ppng or b) Connectng, nstallng, testng, reparng, or servcng equpment; that s experenced n such work; that s famlar wth all precautons requred; and that has compled wth all the requrement of the authorty havng jursdcton. PRODUCT FEATURES SAFETY PILOT Ths heater has a plot wth an Oxygen Depleton Sensng (ODS) safety shutoff system. The ODS plot shuts off the heater f there s not enough fresh ar. TIP OVER SWITCH Ths heater s equpped wth a safety tp over swtch n the event the heater s knocked over. PIEZO IGNITION SYSTEM Ths heater s equpped wth an electronc pezo control system. 3

5 PREPARING FOR INSTALLATION Before begnnng assembly or operaton of the product, make sure all parts are present. Compare parts wth package contents lst and dagram below. If any part s mssng or damaged, do not attempt to assemble, nstall or operate the product. Contact customer servce for replacement parts. Ignter button Control knob Protectve front Fgure 1 gas heater cabnet UNPACKING 1. Remove heater from carton. 2. Remove all protectve packagng appled to heater for shppng 3. Check heater for any shppng damage. If heater s damaged, promptly nform dealer where you bought heater. 4

6 INSTALLATION WARNING: A qualfed servce person must nstall heater. Follow all local codes. Check Gas Type Be sure your gas supply s rght for your heater. Otherwse, call dealer where you bought the heater for proper type heater. Connect Hose & Regulator to Cylnder 1) You must provde propane gas and propane cylnder. Use a standard 20 lb. propane cylnder. 2) Use ths heater only wth a propane vapor wthdrawal supply system. See chapter 5 of the standard for storage and handlng of lquefed petroleum Gas, ANSI/NFPA58. Your local lbrary or fre department should have ths book. 3) The mnmum permssble gas supply nlet pressure of 11 W.C. s requred for purpose of nput adjustment. 4) The normal hourly of 32,000BTU s requred nput ratng for a heater for automatc operaton at ratngs less than full nput ratng. 5) The pressure regulator and hose assembly suppled wth the applance must be used. 6) The regulator hose must be attached to the tank and the heater nsde the heater cabnet. Ths wll make sure the hose s located out of pathways where people may trp over t or n areas where the hose may be subject to accdental damage. 7) The nstallaton must conform wth local codes, or n the absence of local codes, wth Natonal Fuel Gas Code, ANSI Z ) LP-gas supply cylnder to be used must be: (a) Constructed and marked n accordance wth the Specfcatons for LP-gas cylnders of the U.S. Department of Transportaton (DOT); or the Standard for Cylnders, Spheres and Tubes for Transportaton of Dangerous Goods and Commsson, CAN/CSA-B339, as applcable; (b) Provded wth a lsted overfllng preventon devce; and (c) Provded wth a cylnder connecton devce compatble wth the connecton for the applance. 9) A dented, rusted or damaged propane cylnder may be hazardous and should be checked by your cylnder suppler. Never use a propane cylnder wth a damaged valve connecton. 5

7 10) The propane cylnder must be constructed and marked n accordance wth the specfcatons for LP gas cylnders of the U.S. Department of Transportaton (DOT). 11) Never connect an unregulated propane cylnder to the heater. 12) Screw regulator onto gas hose. Dot not cross-thread. 13) Tghten securely. 14) Attach regulator to cylnder. 15) Complete attachment. 16) Install the cylnder and latch closed. 17) Close the rear cover. Fgure 2 Propane Cylnder 6

8 CHECKING GAS CONNECTIONS WARNING: Test all gas ppng and connectons for leaks after nstallng or servcng. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mxture of lqud soap and water to all jonts. If bubbles form, there s a leak. Correct all leaks at once. Pressure Testng Heater Gas Connectons 1) Open gas supply tank valve. 2) Make sure control knob of heater s n the OFF poston. 3) Check all jonts from equpment shutoff valve to control valve. Apply mxture of lqud soap and water to gas jonts. If bubbles form, there may be a leak. 4) Correct all leaks at once. AIR FOR COMBUSTION AND VENTILATION Ths heater s equpped wth multple ventlaton holes n and around the heater. The followng MUST be adhered to when usng ths heater: 1) Adequate clearance MUST always be provded for the ar openng around the heater. 2) Adequate ar MUST be provded nto the combuston chamber. 3) Ths heater MUST always be kept clear of ANY combustble materal. The followng are the mnmum clearances from combustbles: 1) 4 nches from the floor 2) 5 feet from ANY wall or ralng 3) 8 feet from the ANY celng or overhead cover USER MUST NEVER OPERATE THE HEATER WITH ANY VENT COVERED TO ALLOW ADEQUATE FRESH AIR INTO THE HEATER AND COMBUSTION CHAMBER 7

9 OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these nstructons exactly, a fre or exploson may result causng property damage, personal njury or loss of lfe. Before Turnng Gas Supply ON: 1) Your heater was desgned and approved for outdoor use only. Do NOT use t nsde a buldng, garage, or any other enclosed area. 2) Make sure surroundng areas are free of combustble materals, gasolne, and other flammable vapors or lquds. 3) Ensure that there s no obstructon to ar ventlaton. 4) Be sure all gas connectons are tght and there are no leaks by usng soap on the hose. No bubbles should be seen. If you see bubbles then the connecton s not secure. 5) Inspect the gas pressure regulator and hose pror to each use. (f there s evdence of excessve abrason or wear, or f the hose s damaged DO NOT USE THE HEATER. The user MUST replace the hose wth the manufacture specfed replacement hose and regulator) 6) Regulator hose should be connected at the top of the propane cylnder and attached drectly to the heater out of the way area where accdental damage could occur. 7) ONLY the pressure regulator and hose assembly suppled wth the applance must be used 8) Be sure the cylnder cover s clear of debrs. 9) Be sure any component remove durng assembly or servcng s replaced & fastened pror to startng. Before lghtng 1) Heater should be thoroughly nspected before each use and by a qualfed servce person at least annually. 2) If relghtng a hot heater, always wat at least 5 mnutes 3) Inspect the hose assembly for evdence of excessve abrason, cuts, or wear. Suspected areas should be leak tested. If the hose leaks, t must be replaced pror to operaton. Only use the replacement hose assembly specfed by manufacturer. Fgure 3 Control Knobs 8

10 Lghtng 1) STOP! Read the safety nformaton on the nsde of the heater. User MUST follow these lghtng procedures or the heater wll NOT operate properly. 2) Make sure equpment shutoff valve s fully open. 3) Turn control knob clockwse to the OFF poston. 4) Wat fve (5) mnutes to clear out any gas. Then smell for gas, ncludng near the floor. If you smell gas, STOP! Do not try to lght any applance. Do not touch electrcal swtch or use any phone n the buldng. Immedately contact gas suppler from a neghbor s phone. Follow gas suppler s nstructons. If you can t reach the gas suppler, call the fre dept. If you don t smell gas, go to the next step. 5) Turn control knob counterclockwse to the START poston. Press n control knob for fve (5) seconds and smultaneously press the gnter button. Ths wll lght the plot. The user must verfy the plot s lt pror to turnng the knob to the frst flame poston. In the event the plot s not lt you must wat 5 mnutes to relght. 6) Turn control knob to sngle flame symbol. Ths wll lght the bottom 3 ceramc plaques. 7) Turn the knob agan to the double burner symbol and ths wll lght the upper 3 ceramc plaques. (t s best to allow the bottom 3 plaques to warm up frst pror to turnng the top plaques on.) Shut down 1) Turn control knob clockwse to START (normally, burner wll make a slght poppng sound when extngushed.) 2) To extngush plot, depress control knob and contnue to turn t clockwse to OFF. 3) Turn cylnder valve clockwse to OFF and dsconnect regulator when heater s not n use. After operaton check: 1) Gas control s n OFF poston. 2) Gas Tank valve s OFF. 3) Dsconnect gas hose by unscrewng the plastc end attached to the cylnder. 4) Heater s uprght n a secure locaton. 5) Storage of an applance ndoors s permssble only f the cylnder s dsconnected and removed from the applance. 6) A cylnder must be stored outdoors n a well-ventlated area out of the reach of chldren 7) A dsconnected cylnder must have dust caps tghtly nstalled and must not be stored n a buldng, garage or any other enclosed area. 9

11 CARE AND MAINTENANCE WARNING: Turn off heater and let cool before servcng. Any grlls removed for servcng MUST be replaced pror to use. CAUTION: You must keep control areas, burner, and crculatng ar passageways of heater clean. Inspect these areas of heater before each use. Have heater nspected yearly by a qualfed servce techncan. Heater may need more frequent cleanng due to drt and other debrs normally found outdoors. CAUTION: The applance s equpped wth a pezo electrc operated gnton devce. The user MUST follow the proper lghtng nstructons or damage to the heater or fre may occur. CLEANING ODS/PILOT AND BURNER Use a vacuum cleaner, pressurzed ar, or a small, soft brstled brush to clean. CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unt every 2,500 hours of operaton or every three months. We also recommend that you keep the burner tube and plot assembly clean and free of dust and drt. To clean these parts, we recommend usng compressed ar no greater than 30 PSl. Your local computer store, hardware store, or home center may carry compressed ar n a can. You can use a vacuum cleaner n the blow poston. If usng compressed ar n a can, please follow the drectons on the can. If you don t follow drectons on the can, you could damage the plot assembly. 1) Shut off the unt, ncludng the plot. Allow the unt to cool for at least thrty mnutes. 2) Inspect burner and plot for dust and drt. 3) Blow ar through the ports/slots and holes n the burner and clean the plot assembly. A yellow tp on the plot flame ndcates dust and drt n the plot assembly. There s a small plot ar nlet hole about two nches from where the plot flame comes out of the plot assembly (see fgure 2). Wth the unt off, lghtly blow ar through the ar nlet hole. You may blow through a drnkng straw f compressed ar s not avalable. 4) Wth the unt on, vsually check the burner flames to very an even orange pattern on ALL 6 burners. Compare wth fgure 2 below. Fgure 2 (Insert ar cleanng decde through grll to clean burner holes) 10

12 CLEANING THE CABINET Ar Passageways Use a vacuum cleaner or pressurzed ar to clean. Exteror Use a soft cloth dampened wth a mld soap and water mxture. Wpe the cabnet to remove dust. If you need replacement parts you must go to an authorzed dealer for professonal servce! Every part of the heater shall be secure aganst dsplacement and shall be constructed to mantan a fxed relatonshp between essental parts under normal and reasonable condtons of handlng and usage. Parts not permanently secured shall be desgned so they cannot be ncorrectly assembled and cannot be mproperly located or msalgned n removng or replacng durng cleanng or other servcng. TROUBLESHOOTING WARNING: If you smell gas: Open the wndow and door mmedately. Shut off gas supply. Do not try to lght any applance. Do not touch any electrcal swtch; do not use any phone n your buldng. Immedately call your gas suppler from a neghbor s phone. Follow the gas suppler s nstructons. If you cannot reach your gas suppler, call the fre department. IMPORTANT: Operatng heater where mpurtes n ar exst may create odors. Cleanng supples, pant, pant remover, cgarette smoke, cements and glues, new carpet or textles, etc., create fumes. These fumes may mx wth combuston ar and create odors. WARNING: Only a qualfed servce techncan should servce and repar heater. CAUTION: Never use a wre, needle, or smlar object to clean ODS plot. Ths can damage ODS plot unt. Note: All troubleshootng tems are lsted n order of operaton. 11

13 No. PROBLEM POSSIBLE CAUSE REMEDY 1 -When gnter button s pressed n there s no spark at ODS/plot. 2 -When gnter button s pressed n there s a spark at ODS/plot but no gnton. 3 -ODS/plot lghts but flame goes out when control knob s released. 4 -Burner(s) does not lght after ODS/plot s lt. 5 -Delayed gnton of burner(s). 6 -Burner backfrng durng combuston. -- Ignter electrode s postoned wrong or broken. -- Ignter electrode s not connected to gnter cable. -- Ignter cable s pnched or wet. -- Broken gnter cable. -- Bad pezo gnter. -- Gas supply s turned off or equpment shutoff valve s closed. -- Control knob not fully pressed n whle pressng gnter button. -- Ar n gas lnes when nstalled. -- ODS/plot s clogged. -- Gas regulator settng s not correct. -- Control knob not n PILOT poston. -- Depleted gas supply (propane). -- Control knob s not fully pressed n. -- Control knob s not pressed n long enough. -- Equpment shutoff valve s not fully open. -- Thermocouple connecton s loose at control valve. -- Thermocouple damaged. -- Control valve damaged. -- Burner orfce s clogged. -- Burner orfce dameter s too small. -- Inlet gas pressure s too low. -- Manfold pressure s too low. -- Burner orfce s clogged. -- Burner orfce s clogged or damaged. -- Burner s damaged. -- Gas regulator s defectve. --- Replace gnter. --- Reconnect gnter cable. --- Free gnter cable f pnched by any metal or tubng. Keep gnter cable dry. --- Replace gnter cable. --- Replace pezo gnter. --- Turn on gas supply or open equpment shutoff valve. --- Fully press n control knob whle pressng gnter button. --- Contnue holdng down control knob. Repeat gntng operaton untl ar s removed. --- Clean ODS/plot (see Care and Mantenance) --- Replace gas regulator. --- Turn control knob to PILOT poston. --- Contact local propane/lp gas company. --- Press n control knob fully. --- After ODS/plot lghts, keep control knob pressed n 30 seconds. --- Fully open equpment shutoff valve. --- Hand tghten untl snug, and then tghten 1/4 turn more. --- Replace thermocouple. --- Contact customer servce. --- Clean burner orfce (see Care and Mantenance) or replace burner orfce. --- Contact customer servce. --- Contact local gas suppler. --- Contact local gas suppler. --- Clean burner (see Care and Mantenance) or replace burner orfce. --- Clean burner orfce (see Care and Mantenance) or replace. --- Contact customer servce. --- Replace gas regulator. 12

14 7 -Yellow flame durng burner combuston. 8 -Slght smoke or odor durng ntal operaton. 9 -Heater produces a whstlng nose when burner s lt. 10 -Heater produces a clckng/tckng nose just after burner s lt or shut off. 11 -Whte powder resdue formng wthn burner box or on adjacent walls or furnture. 12 -Heater produces unwanted odors. 13 -Heater shuts off n use (ODS operates) Open wndow and/or door for ventlaton. - Contact local gas suppler. - Clean ODS/plot (see Care and Mantenance) 15 -Gas odor durng combuston. 16 -Mosture/condensaton notced on wndows. -- Not enough ar. -- Gas regulator s defectve. -- Inlet gas pressure s too low. -- Resdues from manufacturng processes. -- Turnng control knob to HI poston when burner s cold. -- Ar n gas lne. -- Ar passageways on heater are blocked. -- Drty or partally clogged burner orfce. -- Metal s expandng whle heatng or contractng whle coolng. -- When heated, the vapors from furnture polsh, wax, carpet cleaners, etc., turn nto whte powder resdue. -- Heater s burnng vapors from pant, har spray, glues, etc. -- Gas leak. See Checkng Gas Supply Statement. -- Low fuel supply. -- Not enough fresh ar s avalable. -- Low lne pressure. -- ODS/plot s partally clogged. -- Gas leak. -- Control valve s defectve. -- Foregn matter between control valve and burner. -- Gas leak. -- Not enough combuston/ventlaton ar. --- Check burner for drt and debrs. If found, clean burner (see Care and Mantenance). --- Replace gas regulator. --- Contact local gas suppler. --- Problem wll stop after a few hours of operaton. --- Turn control knob to LO poston and let warm up for a mnute. --- Operate burner untl ar s removed from lne. Have gas lne checked by local gas suppler. --- Observe mnmum nstallaton clearances (Secton). --- Clean burner (see Care and Mantenance) or replace burner orfce. --- Ths s common wth most heaters. If nose s excessve, contact qualfed servce techncan. --- Turn heater off when usng furnture polsh, wax, carpet cleaner, or smlar products. --- Ventlate room. Stop usng odor causng products whle heater s runnng. --- Locate and correct all leaks (see Checkng Gas Connectons) --- Refll supply tank (Propane / LP models). --- Open wndow and/or door for ventlaton. --- Contact local gas suppler. --- Clean ODS/plot (see Care and Mantenance). --- Locate and correct all leaks (see Checkng Gas Connectons ) --- Contact customer servce. --- Take apart gas tubng and remove foregn matter. --- Locate and correct all leaks (see Checkng Gas Connectons ) --- Refer to "Ar for Combuston and Ventlaton requrements 13

15 ILLUSTRATED PART Model: RC9200IT 14

16 PARTS LIST Model: RC9200IT Code Descrpton 1 Man front protectve screen 2 Fastener 1 3 Scatter panel 4 Igntng electrode 5 Burner assembly 6 Burner board 7 Top cover 8 Plastc seat 9 Ignter 10 Ignter assembly 11 Knob 12 Gas ppe nut 13 Plastc seat 14 Gas safety valve 15 Rear back board 16 Fastener 17 Rear cover board 18 Rear nsulaton board 19 Front nsulaton board 20 Tp over safety swtch 21 Unversal wheel-1 22 Supportng bracket 23 ODS bracket 24 ODS/ODS 25 Radant panel assembly 26 Support plate assembly 27 Wnd box 28 Regulator and Hose 15

17 Questons about nstallaton and ntal operaton should be drected to your nstaller. For all other concerns and questons, please reach out to our customer servce team at , by emal at or vst Annual Servce Schedule Servce Performed Servce Date Please regster your product onlne at or send n the regstraton form below to our offce at: Reecon North Amerca 2515 Lberty Ave 1 st Floor Pttsburgh, PA Contact Informaton Product Informaton Name: Model: Phone: Seral Number: Emal: Date of Purchase: Address: Retaler Purchased from: Cty: Installer Company: State: Installer Phone: Zp Code: Installer Zp Code: **All nformaton above s requred n order for our company to honor the warranty** Comments: 16

18

Infrared Cabinet Heater Product Manual MODEL: RC9200IT

Infrared Cabinet Heater Product Manual MODEL: RC9200IT Infrared Cabinet Heater Product Manual MODEL: RC9200IT CAUTION - FOR YOUR SAFETY Reecon North America, L.L.C. 1090 Freeport Road 2 nd Floor Pittsburgh, PA 15238 The installer should leave the instructions

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC INSTANTANEOUS TYPE WATER HEATER FOR USE WITH NATURAL AND LIQUEFIED PETROLEUM GAS

INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC INSTANTANEOUS TYPE WATER HEATER FOR USE WITH NATURAL AND LIQUEFIED PETROLEUM GAS BOSCH NSTALLATON AND OPERATNG NSTRUCTONS FOR AUTOMATC NSTANTANEOUS TYPE WATER HEATER FOR USE WTH NATURAL AND LQUEFED PETROLEUM GAS MODEL 125FX LP and 125FX NG (Flow Modulated wth Electronc gnton and Power

More information

HYTRONIC WITH SSPS USER GUIDE Recommended for Single Supply HyTronic Faucets Only

HYTRONIC WITH SSPS USER GUIDE Recommended for Single Supply HyTronic Faucets Only Cleanng or Replacng Inlet Flter Close supply valves Dsconnect braded hoses and clean or replace flter (for a new flter, see "common replacement parts") Connect braded hoses wth flter to supply valves and

More information

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS 24" (61.0 cm), 27" (68.6 cm), 30" (76.2 cm) Ths product s sutable for use above electrc or gas bult-n ovens, and below non-vented electrc or gas cooktops.

More information

ECOMBI WALL FIXED ELECTRIC STORAGE HEATER INSTALLATION INSTRUCTIONS AND USER GUIDE ECO158 ECO208 ECO308 ECO408

ECOMBI WALL FIXED ELECTRIC STORAGE HEATER INSTALLATION INSTRUCTIONS AND USER GUIDE ECO158 ECO208 ECO308 ECO408 INSTALLATION INSTRUCTIONS AND USER GUIDE ECOMBI WALL FIXED ELECTRIC STORAGE HEATER ECO158 ECO208 ECO308 ECO408 Please read these nstructons CAREFULLY before nstallng or usng ths applance for the frst tme.

More information

SOLISTRAND* and STRATO- THERM* Crimping Heads Used with Double Action Battery Powered Hand Tool Kits [ ]

SOLISTRAND* and STRATO- THERM* Crimping Heads Used with Double Action Battery Powered Hand Tool Kits [ ] SOLISTRAND* and STRATO- THERM* Crmpng Heads Used wth Double Acton Battery Powered Hand Tool Kts 80- [ ] Instructon Sheet 08-00 8 OCT 0 Crmp Head Mountng Holes Battery Powered Crmp Tool Battery Lock Retract

More information

POWERSHRED 425Ci/425i/485Ci/485i

POWERSHRED 425Ci/425i/485Ci/485i https://www.supplychmp.com POWERSHRED /// Please read these nstructons before use. Do not dscard: keep for future reference. Qualty Offce Products Snce 97 https://www.supplychmp.com F. ENGLISH Models ///

More information

ECOMBI SSH INSTALLATION INSTRUCTIONS AND USER GUIDE ECOSSH158 ECOSSH208 ECOSSH308 ECOSSH408 SMART STORAGE HEATER

ECOMBI SSH INSTALLATION INSTRUCTIONS AND USER GUIDE ECOSSH158 ECOSSH208 ECOSSH308 ECOSSH408 SMART STORAGE HEATER INSTALLATION INSTRUCTIONS AND USER GUIDE ECOMBI SSH SMART STORAGE HEATER ECOSSH158 ECOSSH208 ECOSSH308 ECOSSH408 Please, read these nstructons CAREFULLY before nstallng or usng ths applance for the frst

More information

Installation and Operating instructions

Installation and Operating instructions Technology servng manknd Installaton and Operatng nstructons ART Analog room thermostat wth day program for gas fred bolers r. 8610015 Wolf GmbH Postfach 1380 84048 Manburg Tel. +49 8751/74-0 Fax +49 8751/741600

More information

Engine exhaust from this product contains chemicals known, in certain quantities, to cause cancer, birth defects or other reproductive harm.

Engine exhaust from this product contains chemicals known, in certain quantities, to cause cancer, birth defects or other reproductive harm. S ARS OWNERS MANUAL CRRFTSMRNo PORTABLE GENERATOR MODEL NO. 99.32650 MPORTANT: Read the Safety Gudelnes and All nstructons Carefully Before Operatng. SPECFCATON CHART MODEL 99-32650 HORSE POWER 0 RATED/SURGE

More information

CERTI- CRIMP* Hand Crimping

CERTI- CRIMP* Hand Crimping CERTI- CRIMP* Hand Crmpng Instructon Sheet Tool 90185-1 for 408-7278 PIDG* FASTON* Termnals 19 FEB 10 Termnal Crmpng Jaws Back of Tool (Wre Sde) Wre Sze Range Markng Insulaton Crmpng Adjustment Pns (ShownnPoston3)

More information

FCE60 Ignition Box. User Manual

FCE60 Ignition Box. User Manual FCE60 Ignton Box User Manual FCE60 Ignton Box User Manual Kratbjerg 214 - DK 3480 Fredensborg - Denmark - Phone: +45 48 48 26 33 - Emal: sales@tf-technologes.com www.tf-technologes.com 3 About FCE60 User

More information

User Manual. Product: tempmate. -M1 Data Logger Scope: Operations Instructions. For tempmate. -M1 Multiple-Use PDF Temperature Data Logger.

User Manual. Product: tempmate. -M1 Data Logger Scope: Operations Instructions. For tempmate. -M1 Multiple-Use PDF Temperature Data Logger. For tempmate. -M1 Multple-Use PDF Temperature Data Logger Product: tempmate. -M1 Data Logger Scope: Operatons Instructons Summary Theme Page 01. Techncal data 2 02. Devce operaton nstructon 2 03. Intal

More information

ER / CENTRO Model series

ER / CENTRO Model series Exhaust ar system / Recessed-mounted, accordng to DIN 18017-3 ER / CENTRO Model seres Mountng and Operatng Instructons w w w. m a c o - v e n t l a t o r e n. c o m Table of Contents, Intended use Exhaust

More information

FIBARO CO SENSOR OPERATING MANUAL FGBHCD-001 ) ) ) CONTENTS. 4 x BEEP & RED LED BLINKING MOVE TO FRESH AIR!

FIBARO CO SENSOR OPERATING MANUAL FGBHCD-001 ) ) ) CONTENTS. 4 x BEEP & RED LED BLINKING MOVE TO FRESH AIR! OPERATING MANUAL EN ) ) ) 4 x BEEP & RED LED BLINKING MOVE TO FRESH AIR! FIBARO CO SENSOR FGBHCD-001 CONTENTS #1: Descrpton and features 3 #2: Powerng the accessory 4 #3: Parng the accessory 5 #4: Physcal

More information

Q-Test User & Operator Manual S CO CH 4 H 2. Q-Test. Quick and simple in-field gas test and calibration solution

Q-Test User & Operator Manual S CO CH 4 H 2. Q-Test. Quick and simple in-field gas test and calibration solution H 2 S CO CH 4 Q-Test User & Operator Manual Q-Test Quck and smple n-feld gas test and calbraton soluton M070001/ENG Issue 3 Jan 2015 NAVIGATION INSTRUCTIONS The symbols n the left-hand margn of each page

More information

Gas and smoke detectors. (building technology) Gas alarm units. (private home) Gas alarm units (industrial) Gas alarm units. (building technology)

Gas and smoke detectors. (building technology) Gas alarm units. (private home) Gas alarm units (industrial) Gas alarm units. (building technology) Gas and smoke detectors (buldng technology) Gas alarm unts (prvate home) Gas alarm unts (ndustral) Gas alarm unts (buldng technology) Chapter Gas alarm unts Buldng technology Gas alarm unts GS 1.1, GS

More information

HEPA SUPREME AIR OWNERS MANUAL. ._ with ionizer FOR YOUR SAFETY: instructions. -Operating Parts List. i_ e n _r_ iz) P e TM MODELNO. 437.

HEPA SUPREME AIR OWNERS MANUAL. ._ with ionizer FOR YOUR SAFETY: instructions. -Operating Parts List. i_ e n _r_ iz) P e TM MODELNO. 437. f... m SA_E THIS MANUAL FOR FUTURE REFERENCE o f OWNERS MANUAL. MODELNO. 437.83163 / / t t I 1 t. _ e n _r_ z) P e TM HEPA SUPREME AIR CLEANING SYSTEM._ wth onzer FOR YOUR SAFETY: READ ALL NSTRUCTONS CAREFULLY

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL MR HEATER STARTING SERIAL #: MHC1510000001 BASECAMP STARTING SERIAL #: MHC151100000001 OPERATING INSTRUCTIONS AND OWNER S MANUAL MODEL MR. HEATER MH4B READ INSTRUCTIONS CAREFULLY: Read and follow all instructions.

More information

Vent-Free Gas Wall Heater MODEL: WDFT060/100/250-VF-IR (DUAL FUEL) WNT060/100/250-VF-IR (NATURAL GAS) WLT060/100/250-VF-IR (PROPANE GAS)

Vent-Free Gas Wall Heater MODEL: WDFT060/100/250-VF-IR (DUAL FUEL) WNT060/100/250-VF-IR (NATURAL GAS) WLT060/100/250-VF-IR (PROPANE GAS) WARNING: This appliance is equipped for (Natural and/or Propane) gas. Field conversion is not permitted other than between natural or propane gases in dual fuel models only. Vent-Free Gas Wall Heater MODEL:

More information

Vent-Free Gas Wall Heater MODEL: WDFT060/100/250-VF-IR (DUAL FUEL) WNT060/100/250-VF-IR (NATURAL GAS) WLT060/100/250-VF-IR (PROPANE GAS)

Vent-Free Gas Wall Heater MODEL: WDFT060/100/250-VF-IR (DUAL FUEL) WNT060/100/250-VF-IR (NATURAL GAS) WLT060/100/250-VF-IR (PROPANE GAS) WARNING: This appliance is equipped for (Natural and/or Propane) gas. Field conversion is not permitted other than between natural or propane gases in dual fuel models only. Vent-Free Gas Wall Heater MODEL:

More information

Engineered Condensate Solutions

Engineered Condensate Solutions Engneered Condensate Solutons The Mechan of Choce Do you experence mantenance problems wth non-electrc steam/ar powered pus? Are you dung valuable condensate because of frequent mantenance? Do you experence

More information

IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. THIS GUIDE TO BE LEFT WITH EQUIPMENT OWNER. IO-DV070

IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. THIS GUIDE TO BE LEFT WITH EQUIPMENT OWNER. IO-DV070 DEHUMIDIFIER The Clean Comfort DV070 dehumdfer performs multple functons n a compact enclosure: hgh-capacty dehumdfcaton, fresh ar ventlaton, and partculate fltraton. Dehumdfcaton The hghly effcent DV070

More information

R7284U1004 Universal Electronic Oil Primary

R7284U1004 Universal Electronic Oil Primary R784U004 Unversal Electronc Ol Prmary Electronc Ol Prmary wth 5 second lock out tmng and selectable valve and blower delays he R784B,P,U,G Electronc Ol Prmary s a lne voltage, safety rated, nterrupted

More information

I 1.4 SUBMITTALS. RENOVATIONS HOPEWELL TOWNSHIP MUNICIPAL BUILDING TOWNSHIP OF HOPEWELL COMMISSION NO. 10M013 BID # Bi1-15

I 1.4 SUBMITTALS. RENOVATIONS HOPEWELL TOWNSHIP MUNICIPAL BUILDING TOWNSHIP OF HOPEWELL COMMISSION NO. 10M013 BID # Bi1-15 COMMSSON NO. 10M013 BD # B1-15 SECTON 260523 - CONTROL-VOLTAGE ELECTRCAL POWER CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawngs and general provsons of the Contract, ncludng General and Supplementary

More information

Installation Instructions

Installation Instructions Gas Large Capacty Thn Twn Washer Dryer - 120 Volt Installaton Instructons IMPORTANT: Read and save these nstructons. IMPORTANT: Installer: Leave Installaton Instructons wth the homeowner, Homeowner: Keep

More information

RBC AC1 RUN & STANDBY CONTROL DRAWING NUMBER R1956

RBC AC1 RUN & STANDBY CONTROL DRAWING NUMBER R1956 RBC AC & STANDBY CTROL DRAWING NUMBR R HAND AUTO PANL LIV HATR SUPPLY FAN XTRACT FAN PUMP HATR SUPPLY FAN XTRACT FAN PUMP HATR FAN IMAGS RPRSNTATIV OF DIFFRNT CTROL PANLS IMPORTANT PLAS LAV THIS BOOK WITH

More information

Vent-Free Gas Wall Heater MODEL: WDFT060/100/320-VF (DUAL FUEL) WNT060/100/320-VF (NATURAL GAS) WLT060/100/320-VF (PROPANE GAS)

Vent-Free Gas Wall Heater MODEL: WDFT060/100/320-VF (DUAL FUEL) WNT060/100/320-VF (NATURAL GAS) WLT060/100/320-VF (PROPANE GAS) WARNING: This appliance is equipped for (Natural and/or Propane) gas. Field conversion is not permitted other than between natural or propane gases in dual fuel models only. Vent-Free Gas Wall Heater MODEL:

More information

UNVENTED (VENT-FREE) BLUE FLAME GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL

UNVENTED (VENT-FREE) BLUE FLAME GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL UNVENTED (VENT-FREE) BLUE FLAME GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL MANUAL 10,000 BTU - 10542 AND 10543 THERMOSTAT 10,000 BTU - 10544 AND 10545 THERMOSTAT 20,000 BTU - 10546 AND 10547

More information

ENGLISH Installation Page 2 Instructions for use Page IMPORTANT SAFETY INSTRUCTIONS

ENGLISH Installation Page 2 Instructions for use Page IMPORTANT SAFETY INSTRUCTIONS ENGLISH Installaton Page 2 Instructons for use Page IMPORTANT SAFETY INSTRUCTIONS YOUR SAFETY AND THAT OF OTHERS IS VERY IMPORTANT Ths manual and the applance tself provde mportant safety messages, to

More information

INSTRUCTIONS FOR INSTALLING AND USING

INSTRUCTIONS FOR INSTALLING AND USING INSTRUCTIONS FOR INSTALLING AND USING the Intasol Control System July 2010 Introducton The Intaeco Intasol manfold allows unvented hot water heated by solar thermal panels, to be used safely wth a combnaton

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # MH9B READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has

More information

Dräger Polytron 8000 Instructions for Use

Dräger Polytron 8000 Instructions for Use Dräger Polytron 8000 Instructons for Use! WARNING Strctly follow the Instructons for Use. The user must fully understand and strctly observe the nstructons. Use the product only for the purposes specfed

More information

WARNING: This appliance is equipped for Natural and Propane gas. Field conversion is not permitted other than between natural or propane gases.

WARNING: This appliance is equipped for Natural and Propane gas. Field conversion is not permitted other than between natural or propane gases. VENT-FREE GAS WALL HEATER OWNER S OPERATION AND INSTALLATION MANUAL BLUE FLAME MODELS FDT10BF, FDT20BF & FDT30BF FDT30BF Shown WARNING: If the information in this manual is not followed exactly, a fire

More information

ECU- 1 1 mm Socket Contact 25 FEB 10 Rev E

ECU- 1 1 mm Socket Contact 25 FEB 10 Rev E Applcaton Specfcaton 114-6071 ECU- 1 1 mm Socket Contact 25 FEB 10 Rev E All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are n mllmeters. Unless otherwse specfed, dmensons

More information

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS CSA Model 98300 DRF01000 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas: 1.

More information

' )! Model WFK 2401 / \ / IMPORTANT SAFETY INSTRUCTIONS GROUNDING INSTRUCTIONS KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.

' )! Model WFK 2401 / \ / IMPORTANT SAFETY INSTRUCTIONS GROUNDING INSTRUCTIONS KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. BOSCH Use & Care Manua_ Model WFK 2401 Tumble Clothes Acton Washer / \ m " * C) ' )! 1 Qu_nce / Index IMPORTANT SAFETY INSTRUCTIONS GROUNDING INSTRUCTIONS 2-3 2 ABOUT YOUR WASHER 4 GETTING TO KNOW YOUR

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL PORTABLE BUDDY RADIANT HEATER

OPERATING INSTRUCTIONS AND OWNER S MANUAL PORTABLE BUDDY RADIANT HEATER OPERATING INSTRUCTIONS AND OWNER S MANUAL PORTABLE BUDDY RADIANT HEATER Model # MH9BX READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference.

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL Serial Numbers 734000000001000-7340000000169215 OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # MH9B READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. VENT-FREE PROPANE/LP GAS SPACE HEATER OWNER S OPERATION AND INSTALLATION MANUAL INFRARED MODELS ML060HPA, ML100HPA ML100TPA WARNING: If the information in this manual is not followed exactly, a fire or

More information

VENT-FREE PROPANE GAS HEATER

VENT-FREE PROPANE GAS HEATER VENT-FREE PROPANE GAS HEATER OWNER S OPERATION AND INSTALLATION MANUAL Models: VP2000BA, VP2000BTA, and VP2800BTA WARNING: If the information in this manual is not followed exactly, a fire or explosion

More information

User Manual. 600mm Steam Convection Oven Model No: SCG36

User Manual. 600mm Steam Convection Oven Model No: SCG36 User Manual 600mm Steam Convecton Oven Model No: SCG36 Preface Dear Customer, Congratulatons on purchasng your new product from Home Applances. To regster your Parts and Labour Warranty, some condtons

More information

PAULIN PRODUCTS INDOOR HEATER

PAULIN PRODUCTS INDOOR HEATER PAULIN PRODUCTS INDOOR HEATER OWNER S MANUAL AND OPERATING INSTRUCTIONS May be used with a disposable 1 lb. propane cylinder: - for emergency indoor home heating - for indoor use in commercial enclosures,

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL OPERATING INSTRUCTIONS AND OWNER S MANUAL MR. HEATER READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has

More information

User s Manual & Operating Instructions

User s Manual & Operating Instructions User s Manual & Operating Instructions Model Number HH-18-PCH-A Factory ID: 522 DANGER CONSUMER: READ AND SAVE THESE INSTRUCTIONS GENERAL HAZARD : FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS

More information

y from the washing machine! n:sk of poisoning or chemk:a/ burns, ing products out of tho reach of children.

y from the washing machine! n:sk of poisoning or chemk:a/ burns, ing products out of tho reach of children. Congratulatons- You have chosen a modern, hgh-qualty home applance from Bosch. Tho washng machno foaturos both wator and energy savngs. Every machne that leaves our factory s carefully tested for functon

More information

Installation and Servicing Instructions GREENSTAR HE plus combi

Installation and Servicing Instructions GREENSTAR HE plus combi Installaton and Servcng Instructons GREENSTAR HE plus comb Wall mounted condensng boler for central heatng and mans fed domestc hot water 6 720 610 598-00.1O ZWBR 7-30 HE plus GC-Number: 47 311 75 ZWBR

More information

Vent-Free Gas Wall Heater Blue Flame

Vent-Free Gas Wall Heater Blue Flame Vent-Free Gas Wall Heater Blue Flame WARNING:This appliance is equipped for (Natural and Propane) gas. Field conversion is not permitted other than between natural or propane gases. Model # MD100TBA MD200TBA

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL Serial numbers on back cover. OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # MH9BX READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference.

More information

User s Manual and Operating Instructions. Model: MH-18-PCH-A

User s Manual and Operating Instructions. Model: MH-18-PCH-A User s Manual and Operating Instructions Model: MH-18-PCH-A DE C Table of Contents Safety Information...2-3 Supply / Information...3 Checking For Leaks...3 Product Features...3-4 Unpacking and Assembly...4

More information

MODELS PCS100T AND PCS150T PFS

MODELS PCS100T AND PCS150T PFS VENT-FREE GAS FIREPLACE INSERT OWNER S OPERATION AND INSTALLATION MANUAL MODELS PCS100T AND PCS150T PFS US WARNING: If the information in this manual is not followed exactly, a fire or explosion may result

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. VENT-FREE GAS FIREPLACE INSERT OWNER S OPERATION AND INSTALLATION MANUAL MODEL FDF150T PFS US WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. VENT-FREE NATURAL GAS SPACE HEATER OWNER S OPERATION AND INSTALLATION MANUAL BLUE FLAME MODELS MN060HBA, MN100HBA MN100TBA WARNING: If the information in this manual is not followed exactly, a fire or

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # MH18B READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has

More information

PFS VENT-FREE GAS SYSTEM OWNER'S OPERATION AND INSTALLATION MANUAL

PFS VENT-FREE GAS SYSTEM OWNER'S OPERATION AND INSTALLATION MANUAL VENT-FREE GAS SYSTEM OWNER'S OPERATION AND INSTALLATION MANUAL MODELS FDF400T-ZC SERIES PFS US WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing

More information

Model Numbers REM-18-PCH-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS. Safety Information

Model Numbers REM-18-PCH-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS. Safety Information CABINET HEATER User s Manual & Operating Instructions Model Numbers REM-18-PCH-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS Safety Information GENERAL HAZARD : DANGER FAILURE TO COMPLY WITH THE PRECAUTIONS

More information

Repeat procedures for other side.

Repeat procedures for other side. Repeat procedures for other side. ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. CSA Model 98900 Printed in China DANGER

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. UNVENTED (VENT-FREE) BLUE FLAME GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL Models GWN6, GWP6, GWN10, GWP10 GWN10T AND GWP10T WARNING: If the information in this manual is not followed exactly,

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. VENT-FREE NATURAL GAS SPACE HEATER OWNER S OPERATION AND INSTALLATION MANUAL BLUE FLAME MODELS MN200HBA, MN200TBA MN300HBA, MN300TBA WARNING: If the information in this manual is not followed exactly,

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. BLUE FLAME VENT-FREE PROPANE/LP GAS SPACE HEATER OWNER S OPERATION AND INSTALLATION MANUAL MODELS ML200HBA, ML200TBA ML300HBA, ML300TBA WARNING: If the information in this manual is not followed exactly,

More information

Power Ring Connectors 19 FEB 10 Rev C

Power Ring Connectors 19 FEB 10 Rev C Applcaton Specfcaton 114-2087 Power Rng Connectors 19 FEB 10 Rev C All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are n mllmeters [and nches]. Unless otherwse specfed,

More information

Using it in an enclosed space can kill you.

Using it in an enclosed space can kill you. 38 X 56 GAS FIRE PIT - OWNER S MANUAL Carlisle Chat Fire Table Base Model # 00GBC7 (6877B) Fits 6877A Carlisle Chat Fire Table Top For Propane and *Natural Gas (*See Page 7) Certified to CSA International

More information

Kozy-WorldR OWNER S OPERATION AND INSTALLATION MANUAL. Table of Contents. Save this manual for future reference. KWN111

Kozy-WorldR OWNER S OPERATION AND INSTALLATION MANUAL. Table of Contents. Save this manual for future reference. KWN111 Kozy-WorldR INFRARED VENT-FREE NATURAL GAS SPACE HEATER OWNER S OPERATION AND INSTALLATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing

More information

User s Manual and Operating Instructions. Model: HH-18-PCH. Carbon Monoxide Hazard This heater produces carbon monoxide, which has no odor.

User s Manual and Operating Instructions. Model: HH-18-PCH. Carbon Monoxide Hazard This heater produces carbon monoxide, which has no odor. User s Manual and Operating Instructions Model: HH-18-PCH Table of Contents Safety Information...2-3 Specifications...3 Supply / Information...3 Checking For Leaks...3 Product Features...3-4 Unpacking

More information

VENT-FREE FREESTANDING PEDESTAL STOVE SYSTEM OWNER S OPERATION AND INSTALLATION MANUAL

VENT-FREE FREESTANDING PEDESTAL STOVE SYSTEM OWNER S OPERATION AND INSTALLATION MANUAL VENT-FREE FREESTANDING PEDESTAL STOVE SYSTEM OWNER S OPERATION AND INSTALLATION MANUAL THERMOSTATICALLY - CONTROLLED MODELS CS26PT AND CS26NT 20,000 TO 26,000 BTU/HR WARNING: If the information in this

More information

SAFA/ S P/N (9511

SAFA/ S P/N (9511 SAFA/ S _y nstallaton nstructons // washer/dryer 240 volts SAVE THESE NSTRUCTONS P/N 131531700 (9511 Before you begn. Please read these nstructons way :hrough. _ screwdrver /_ Socket _JPlers screwdrver

More information

Vent-Free Gas Wall Heater Blue Flame

Vent-Free Gas Wall Heater Blue Flame Vent-Free Gas Wall Heater Blue Flame WARNING:This appliance is equipped for (Natural and Propane) gas. Field conversion is not permitted other than between natural or propane gases. Model # MD100TBA MD200TBA

More information

For more information, visit Propane/LP and Natural Gas Thermostat Control Gas Log Heaters (Burner System For Cast Iron Stoves)

For more information, visit  Propane/LP and Natural Gas Thermostat Control Gas Log Heaters (Burner System For Cast Iron Stoves) (VENT-FREE) GAS STOVE HEATER OWNER S OPERATION AND INSTALLATION MANUAL CSBNT CSBPT CSPBNT CSPBPT CSPINT CSPIPT Propane/LP and Natural Gas Thermostat Control Gas Log Heaters (Burner System For Cast Iron

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL Models GWRP16, GWRn18, GWRP26, GWRn30 GWRP16T, GWRn18T, GWRP26T and GWRn30T WARNING: If the information in this manual

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL Models GWRP16A, GWRn18A, GWRP26A, GWRn30A GWRP16TA, GWRn18TA, GWRP26TA and GWRn30TA WARNING: If the information in this

More information

VENT-FREE PROPANE/LP GAS HEATER

VENT-FREE PROPANE/LP GAS HEATER VENT-FREE PROPANE/LP GAS HEATER OWNER S OPERATION AND INSTALLATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal

More information

Vent-Free Gas Infrared space Heater

Vent-Free Gas Infrared space Heater Vent-Free Gas Infrared space Heater MN180TPH MN180HPH MN300TPH MN300HPH ML150TPH ML150HPH ML250TPH ML250HPH CAUTION - FOR YOUR SAFETY WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY,

More information

CAUTION FOR YOUR SAFETY

CAUTION FOR YOUR SAFETY VENT-FREE GAS FIREBOX Model # PC32VFC & PC36VFC CAUTION FOR YOUR SAFETY WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. VENT-FREE NATURAL GAS SPACE HEATER OWNER S OPERATION AND INSTALLATION MANUAL INFRARED MODELS MN180HPA, MN180TPA MN300HPA, MN300TPA WARNING: If the information in this manual is not followed exactly, a

More information

229c4053P INSTALLATION INSTRUCTIONS FOR YOUR NEW IMPORTANT SAFETY INSTRUCTIONS TOOLS YOU WILL NEED ADDITIONAL MATERIALS YOU MAY NEED

229c4053P INSTALLATION INSTRUCTIONS FOR YOUR NEW IMPORTANT SAFETY INSTRUCTIONS TOOLS YOU WILL NEED ADDITIONAL MATERIALS YOU MAY NEED -.... NSTALLATON NSTRUCTONS FOR YOUR NEW 30 sealed GAS COOKTOP Before you begin Read these instructions completely and carefully. MPORTANT-Save MPORTANT-QBSER~ Note to nstaller-be these instructions for

More information

CBN20, CBP20 SBN20, SBP20 CBN20T, CBP20T CBN30T, CBP30T CBT20NT, CBT20PT CBT30NT, CBT30PT CBN20TK, CBP20TK

CBN20, CBP20 SBN20, SBP20 CBN20T, CBP20T CBN30T, CBP30T CBT20NT, CBT20PT CBT30NT, CBT30PT CBN20TK, CBP20TK UNVENTED (VENT-FREE) BLUE FLAME GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL CBN20, CBP20 SBN20, SBP20 CBN20T, CBP20T CBN30T, CBP30T CBT20NT, CBT20PT CBT30NT, CBT30PT CBN20TK, CBP20TK WARNING:

More information

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS CSA Model98900 DRS02403 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas:

More information

Installation and Service Instructions. Economite BILL OF MAT'L NUMBER. Name. Address. Phone

Installation and Service Instructions. Economite BILL OF MAT'L NUMBER. Name. Address. Phone and Service nstructions Economite RE4850BA / RE4700BA RE4400B / RE4400BA Gas Burners n the United States, must conform with local codes or, in the absence of local codes, with of the National Fuel Gas

More information

VTeleAlarm. NurseCall. NurseCall Main Unit. User Manual

VTeleAlarm. NurseCall. NurseCall Main Unit. User Manual VTeleAlarm NurseCall NurseCall Man Unt User Manual NurseCall Man Unt en 3 Table of Contents 1 Identfcaton 7 1.1 Document 7 1.2 Customer support addresses 8 2 Generaltes 9 2.1 Document 9 2.2 NurseCall

More information

Operating instructions

Operating instructions ENG Operatng nstructons Condensng ol-fred boler UltraOl (80) Hoval Swtzerland Hoval Herzog AG CH-8706 Feldmelen General Wlle-Strasse 201 Tel. 044 / 925 61 11 Fax 044 / 923 11 39 Hoval Austra Hoval Gesellschaft

More information

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.), Hanover Outdoor Furniture IMPORTANT If you have any problems with this product (missing or damaged parts, assembly issues, etc.), PLEASE DO NOT RETURN TO THE RETAILER/STORE from where you purchased the

More information

WARNING. PROPANE FORCED AIR HEATER User s Manual & Operating Instructions. Safety Information

WARNING. PROPANE FORCED AIR HEATER User s Manual & Operating Instructions. Safety Information Model Numbers MH-40-GFA / MH-60V-GFA-A / MH-125V-GFA-A / MH-150V-GFA-A MH-60V-GFA / MH-125V-GFA, MH-150V-GFA CONSUMER: READ AND SAVE THESE INSTRUCTIONS Safety Information GENERAL HAZARD : DANGER FAILURE

More information

UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL

UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL FLAME-MAX Golden Oak Log Design FLAME-MAX Vintage Oak Log Design FLAME-MAX Birch Log Design 18", 24", and 30" Variable

More information

User s Manual & Operating Instructions Model Numbers MH-40-GFA / MH-60V-GFA-A / MH-125V-GFA-A / MH-150V-GFA-A

User s Manual & Operating Instructions Model Numbers MH-40-GFA / MH-60V-GFA-A / MH-125V-GFA-A / MH-150V-GFA-A User s Manual & Operating Instructions Model Numbers MH-40-GFA / MH-60V-GFA-A / MH-125V-GFA-A / MH-150V-GFA-A DANGER CONSUMER: READ AND SAVE THESE INSTRUCTIONS GENERAL HAZARD : FAILURE TO COMPLY WITH THE

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. CSA Model99000 BRH01000 DANGER If you smell gas: 1. Shut off gas to the

More information

Unparalleled. built into every home Jayman BUILT CORE PERFORMANCE

Unparalleled. built into every home Jayman BUILT CORE PERFORMANCE Unparalleled bult nto every home. 2016 Jayman BUILT CORE PERFORMANCE A HIGHER STANDARD A home s one of the most mportant purchases you ll make n your lfetme, and we beleve you should get as much as possble

More information

TERRACE AND PATIO HEATER

TERRACE AND PATIO HEATER TERRACE AND PATIO HEATER USER INSTALLATION AND OPERATION GUIDE INDEX General and specifications.1,2 Security and caution.. 3 Tools and accessories required 5 Assembly instructions 5-7 Operation (Lighting

More information

VarPlus Logic VL series PF Correction Controller

VarPlus Logic VL series PF Correction Controller Low Voltage VarPlus Logc VL seres PF Correcton Controller VarPlus Logc VL6 / VL12 PFC controller: to download the user manual or other documentaton vst www.schneder-electrc.com. Type de devce model (for

More information

VENT-FREE INFRARED GAS WALL HEATER

VENT-FREE INFRARED GAS WALL HEATER VENT-FREE INFRARED GAS WALL HEATER MODEL # Propane (C)(GC)IR6PMA (C)(GC)IR10PTA/PMA (C)(GC)IR16PTA/PMA (C)(GC)IR26PTA/PMA Natural Gas (C)(GC)IR6NMA (C)(GC)IR10NTA/NMA (C)(GC)IR18NTA/NMA (C)(GC)IR30NTA/NMA

More information

Dräger Polytron 8000/8200/8700/8720

Dräger Polytron 8000/8200/8700/8720 Dräger Polytron 8000/8200/8700/8720 Safety Manual Vers. 2.0 Rev. R1, Feb. 2012 Content Content 1 Scope and purpose of safety manual..........4 2 Relevant standards.........................4 3 For your

More information

Operating instructions

Operating instructions EN Operatng nstructons Condensng gas heatng boler UltraGas (15-720) Hoval Unted Kngdom Hoval LTD Northgate Newark Nottnghamshre NG24 1JN Phone: +44 1636 67 27 11 Fax: +44 1636 67 35 32 Hoval Export Hovalwerk

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS CSA Model 99000 ARL00100 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas: 1. Shut off gas to the

More information

UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER

UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL FLAME-MAX Vintage Oak Log Design FLAME-MAX Golden Oak Log Design FLAME-MAX Birch Log Design 18" and 24" Variable

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. VENT-FREE FREESTANDING PEDESTAL STOVE SYSTEM OWNER S OPERATION AND INSTALLATION MANUAL Thermostatically - Controlled Models CFS26NT, CFS26PT, S26PTA and S26NTA 20,000 to 26,000 Btu/Hr WARNING: If the information

More information

VENT-FREE BLUE FLAME GAS WALL HEATER

VENT-FREE BLUE FLAME GAS WALL HEATER WARNING: This appliance is equipped for Natural and Propane gas. Field conversion is not permitted. WARNING: Do not attempt to access or change the setting of the fuel selection means. Access to and adjustment

More information

Living. Installation Programming Operating. EF Series Alarms (EF-KIT1 & EF-KIT4) smart. Keep this manual safe for reference and future maintenance

Living. Installation Programming Operating. EF Series Alarms (EF-KIT1 & EF-KIT4) smart. Keep this manual safe for reference and future maintenance smart Lvng EF Seres Alarms (EF-KIT1 & EF-KIT4) Installaton Programmng Operatng Keep ths manual safe for reference and future mantenance Introducton Contents Thank you for choosng ths Yale EF Seres Alarm

More information

PRE-PLANNING GUIDE for the Linear Burner System

PRE-PLANNING GUIDE for the Linear Burner System PRE-PLANNING GUIDE for the Linear Burner System GAS PRESSURE SPARK products are engineered, safety tested and certified to function properly within a specific gas supply pressure range. It is CRITICALLY

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. OPERATING INSTRUCTIONS AND OWNER S MANUAL READ INSTRUCTIONS CAREFULLY: Read and follow all instructions.

More information

Model Numbers REM-80V-LPC-O / REM-200V-LPC-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS

Model Numbers REM-80V-LPC-O / REM-200V-LPC-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS Model Numbers REM-80V-LPC-O / REM-200V-LPC-O CONVECTION HEATER User s Manual & Operating Instructions Factory ID: 522 DANGER CONSUMER: READ AND SAVE THESE INSTRUCTIONS GENERAL HAZARD : FAILURE TO COMPLY

More information

ESM x35 DIN Size Digital Process Indicator. ESM x 35 DIN Size Digital Process Indicator

ESM x35 DIN Size Digital Process Indicator. ESM x 35 DIN Size Digital Process Indicator ESM-3700 77x35 DIN Sze Dgtal rocess Indcator ESM-3700 77 x 35 DIN Sze Dgtal rocess Indcator - 4 Dgts dsplay - Easly adjustable from front panel - Confgurable dsplay scale between -1999 and 9999 - Adjustable

More information