The High-efficiency Air-cooled Chiller "H series"

Size: px
Start display at page:

Download "The High-efficiency Air-cooled Chiller "H series""

Transcription

1 R07C

2 NEW The High-efficiency Air-cooled Chiller "H series" The air-cooled chiller "H series" with improved efficiency and functionality by several advanced technologies. This series with the world's best standard A-type screw compressor and newly designed shell and tube heat exchanger that have powerful cooling ability, low noise, low vibration, high efficiency and high reliability is the perfect answer to all your needs!! E nhanced Line-up ~up to 00 HP~ High-performance A-type Screw Compressor P recise Capacity Control Technology E xcellent Control Function 1 Highly Reliable Shell and Tube Heat Exchanger

3 Improved heat-exchange performance by using inverse M type Air Side Heat Exchanger Protection Net (standard equipment) Acoustic Chamber (standard equipment) Product Series R07C RCUG-ATHYZ1 Nominal Capacity Range (50Hz)* 110 to 1,09 31 to 310 9,00 to 93,50 RCU-ATHYZ1 Nominal Capacity Range (50Hz)* 11 to 1,1 33 to 3 99,70 to 95,50 * The nominal cooling capacities are based on the following conditions: Chilled Water Inlet/Outlet Temperature : 1 C/7 C Condenser Temperature : 35 C (DB) Wide Line-up To meet the need for air conditioning systems for large facilities and the demand for higher capacity industrial cooling systems. RCUG-ATHYZ (HP) R07C RCU-ATHYZ (HP)

4 Technical Features High-performance A-type Screw Compressor ~Newly Designed~ NEW Built-in Cyclone Oil Separator Low oil carrying-out is realized and reduction of heat transfer efficiency is minimized. High Technology by Internal Manufacture Because all manufacturing processes, from rotor manufacturing to unit assembly, are done internally, exceptional reliability is achieved. New Screw Compressor Operation Image No outside pump is required due to the reliable differential-pressure oil-feeding system. This oil-feeding system, which does not use any electrical mechanism, prevents the compressor from being damaged and maintains long-term stable operation. Suctioned Refrigerant Gas Oil Screw Rotor Discharged Gas Oil Reservoir Cyclone Oil Separator Differential Pressure Lubrication Mechanism Simple Structure with a Small Number of Parts Whereas the number of main parts for the casing, compression mechanism and capacity control mechanism of a reciprocating compressor is, that of a screw compressor is only 7, just one tenth of the number! A structure with so few parts offers high reliability and easy maintenance. Low Vibration Level No exclusive vibration control equipment is necessary by using low-vibration screw compressor. Vibration Comparison Type Reciprocating Comp. speed (rpm) 50/0Hz 1,30 / 1,70,0 / 3,70 Full amplitude Screw At leg of comp At base frame 0 Less than 10 Vib. frequecy At leg of comp. 3. /.7.5 / 57. At base frame 3. /.7 / 57. Acceleration energy Screw: 1/5 of reciprocating type 3

5 P recise Capacity Control Technology The temperature of the chilled water outlet can be kept at the set temperature ±1 C by continuous capacity control, so it is suitable for industrial use. Start Outlet water temperature 1sec. A given load status is maintained. Load-up signal 0sec. Inlet water temperature sec. sec. Load-up signal Load-down signal 0sec. 0sec. When there is a big difference between set temperature and actual temperature. Stop Inlet water temperature Outlet water temperature Neutral zone standard Stop temperature standard Lapsed time The inlet water temperature is detected at a stop, and it is restarted by a rise in inlet water temperature. Slide Valve Bypass Gas Suction Gas Capacity Controller Structural Outline (HITACHI Patented System) Rotor Load-up Pd SV1 High Pressure Oil Ps Low Pressure Gas SV3 SV Slide Valve Bypass Gas Suction Gas Rotor Pd: Discharge pressure, Ps: Suction pressure, SV1,,3 : Solenoid valve : Valve open : Valve close Load-down Pd SV1 Low Pressure Gas Ps SV3 SV High Pressure Oil E xcellent Control Function Building Management System (BMS) Hitachi uses Building Management System through LONWORKS R. For chiller air-conditioning, Hitachi provides its own central station system. No complicated work is necessary. * : "LONWORKS R " is a trademark of Echelon Corporation registered in the United States and other countries. BMS System (Supplied by BMS Maker) * Other Building Equipment List of Functions Remote Setting ON / OFF Operation Chilled Water Temperature (Inlet or Outlet) G/W counication adapter (option) G/W counication adapter (option) can be connected up to units. * Equipment below the dotted line is provided by HITACHI Remote Monitor ON / OFF Status Setting Chilled Water Temperature (Inlet or Outlet) Current Water Temperature of Inlet and Outlet Alarm Code In addition, up to units can be connected using the G/W counication * adapter for the Hitachi Chiller Unit signal (RS5). Highly Reliable Shell and Tube Heat Exchanger ~Newly Designed~ Dry expansion cooler system Low environmental impact: refrigerant quantity reduced by 0% from the current unit Perfect matching with the chiller unit due to our own design - Downsized by redesigned heat-transfer tube - Improved efficiency by optimized refrigerant distribution

6 R07C General Data 5 Power Source Nominal Cooling Capacity* 1 Nominal Cooling Capacity* Capacity Control Outer Net Weight Refrigerant Compressor Heat Exchanger Safety Devices Piping Connections for Water Side Heat Exchanger (Inlet/Outlet) Connection Hole Shipping Weight* Shipping Main Power (square orifice) Circuit Compressor Input* 1 Compressor Input* Power Source Capacity Control Outer Net Weight Refrigerant Compressor Heat Exchanger Safety Devices % Standard Flow Control Number of Circuits Type Quantity Condenser Condenser Fan Fan Power Input Motor Quantity Air Discharge m 3 /min. Evaporator Nominal Cooling Capacity* 1 Nominal Cooling Capacity* Piping Connections for Water Side Heat Exchanger (Inlet/Outlet) Connection Hole Shipping Weight* Shipping Main Power (square orifice) Circuit Compressor Input* 1 Compressor Input* % Standard Flow Control Number of Circuits Type Quantity Condenser Condenser Fan Fan Power Input Motor Quantity Air Discharge m 3 /min. Evaporator RCUG0ATHYZ ,00 9,0 1,790 0ASCC-Z RCUG50ATHYZ1 RCUG0ATHYZ1 RCUG75ATHYZ1 RCUG100ATHYZ1 Main (AC 3) 30, 15V / 50Hz, Control (AC 1) 0, 0V / 50Hz , , , , , , , ,50 1,90,100, ,90 3,10 50ASCC-Z 1,0 Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve With 1 Inner Diameter With 90 Inner Diameter Companion Flange Companion Flange,000, RCUG70ATHYZ , ,0 1,30 50ASCC-Z,00, ,00(min.) 3,30 + 3,0 x 3,30 + 3,70 100~15, 0,390 1,70 R07C x 10 ;.5; 10; 5,00, x;.5; 10; 5 3,10, Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve x; x.5; x10; x5 3,70 + 3,0 x 3,70 x,700 x, RCUG300ATHYZ1 RCUG330ATHYZ1 RCUG350ATHYZ1 RCUG30ATHYZ1 Main (AC 3) 30, 15V / 50Hz, Control (AC 1) 0, 0V / 50Hz 7 0, , , , ,0 1, , ,0 x 3,70 0,0 100~15()* 3, 0 11,10(min.),5 + 3,30, ,30 R07C ,50,50 With 1 Inner Diameter Companion Flange x 500 x 10 5 x; x.5; x10; 3 x5 5, ,70 5, ,70,00 +,700,00 +, ,0(min.) x,5 x 1 5,50 x; x.5; x10; x5 x 5,500 x,

7 R07C RCUG10ATHYZ , ,10 3,0 1,0,90 RCUG150ATHYZ1 RCUG10ATHYZ1 RCUG10ATHYZ1 RCUG00ATHYZ1 Main (AC 3) 30, 15V / 50Hz, Control (AC 1) 0, 0V / 50Hz , , , , , , , ,30 1,0 100~15(5)* 3, 0,590,75,5 R07C 3 50ASCC-Z 3 1 1,790,790 Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve With 1 Inner Diameter Companion Flang,900 1,790 RCUG0ATHYZ , ,0 9,00(min.) x 3,0 x 3, x 10 x 500 x 10 x;.5; 10; 5 3,0, ,70, RCUG30ATHYZ1 RCUG00ATHYZ1 Main (AC 3) 30, 15V / 50Hz, Control (AC 1) 0, 0V / 50Hz 1,055 1, ,300 93, ,0 3,00 13,0(min.),900 +,5 x,900 R07C x 1 5,50 5,50 Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve 5,30, NOTES: 3 x;.5; 10; x5 5,500, The nominal cooling capacities are based on the following conditions: *1 Chilled Water Inlet/Outlet Temperature 1 C/7 C Condenser Temperature 35 C (DB) * Chilled Water Inlet/Outlet Temperature 1 C/7 C Condenser Temperature C (DB).The units greater than 0ATHYZ1 including 0ATHYZ1 consist of two modules and are separately shipped.(*). The coon chilled water piping (Filed-Supplied) between each water cooler shall be directly connected at site. 3. Water Flow 1) RCUG0,300,30,00ATHYZ1 It is necessary to control the coon water flow volume to each cooler. ) RCUG70,330,350,30ATHYZ1 The chilled water flow rate is different between No.1 & No. units. It is necessary to control the water flow volume of each unit with adjusting valves (Filed-Supplied).. It is required to connect electrical control wires between No.1&No. units for the unit greater than 0ATHYZ1 including 0ATHYZ1. 5. ( )marked with *3 is available by selection switch.. Companion flanges are factory supplied. 5,535, x; x.5; x10; x5 x 3,0 x, Counication adapter connecting the unit to BMS (Building Management System) is an optional accessory, please contact with HITACHI or HITACHI distributor if required. For the details, please refer to Technical Catalog. With 1 Inner Diameter Companion Flange x 500 x 10 x; x.5; x10; x5 5, ,500 x 5,535 x,00 x, Working Range Item Chilled Water Outlet Temperature Condenser Air Inlet Temperature (DB) Standard 5~10 C 5~5 C Options Heat Recovery System Separate LCD Control Panel

8 Power Source Nominal Cooling Capacity* 1 Nominal Cooling Capacity* Capacity Control Outer Net Weight Refrigerant Compressor Heat Exchanger Safety Devices General Data Piping Connections for Water Side Heat Exchanger (Inlet/Outlet) Connection Hole Shipping Weight* Shipping Compressor Input* 1 Compressor Input* Main Power (square orifice) Circuit % Standard Flow Control Number of Circuits Type Quantity Condenser Condenser Fan Fan Power Input Motor Quantity Air Discharge m 3 /min. Evaporator RCU0ATHYZ , ,0 1,790 0ASCC-Z RCU50ATHYZ1 RCU0ATHYZ1 RCU75ATHYZ1 Main (AC 3) 30, 15V / 50Hz, Control (AC 1) 0, 0V / 50Hz , , , , ,0 1 1,0 100~15, 0,390 1,30 1,70 1, ASCC-Z 1,100, RCU100ATHYZ1 1 5, ,0,90 3,10 50ASCC-Z 1,0 Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve With 1 Inner Diameter With 90 Inner Diameter Companion Flange Companion Flange,000, ,00, x 10 ;.5; 10; 5,00, x;.5; 10; 5 3,10, Power Source Nominal Cooling Capacity* 1 Nominal Cooling Capacity* Capacity Control Outer Net Weight Refrigerant Compressor Heat Exchanger Safety Devices Piping Connections for Water Side Heat Exchanger (Inlet/Outlet) Connection Hole Shipping Weight* Shipping Main Power (square orifice) Circuit Compressor Input* 1 Compressor Input* % Standard Flow Control Number of Circuits Type Quantity Condenser Condenser Fan Fan Power Input Motor Quantity Air Discharge m 3 /min. Evaporator RCU70ATHYZ , ,0 9,00(min.) 3,30 + 3,0 x 3,30 + 3,70 Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve x; x.5; x10; x5 3,70 + 3,0 x 3,70 x,700 x, RCU300ATHYZ1 RCU330ATHYZ1 RCU350ATHYZ1 Main (AC 3) 30, 15V / 50Hz, Control (AC 1) 0, 0V / 50Hz , , , , ,00 x 3,70 9,0 100~15()* 3, 0 11,10(min.),5 + 3,30, , ,50,50 With 1 Inner Diameter Companion Flange x 500 x 10 5 x; x.5; x10; 3 x5 5, ,70 5, ,70,00 +,700,00 +, RCU30ATHYZ1 1, ,0 9 11,0 13,0(min.) x,5 x 1 5,50 x; x.5; x10; x5 x 5,500 x,

9 RCU10ATHYZ , ,900 3,0 1,0,90 RCU150ATHYZ1 RCU10ATHYZ1 RCU10ATHYZ1 RCU00ATHYZ1 Main (AC 3) 30, 15V / 50Hz, Control (AC 1) 0, 0V / 50Hz , , , , , , , ,0 3,30 1,0 100~15(5)* 3, 0,590,75,5 3 50ASCC-Z 3 1 1,790,790 Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve With 1 Inner Diameter Companion Flang,900 1,790 RCU0ATHYZ , ,00 9,00(min.) x 3,0 x 3, x 10 x 500 x 10 x;.5; 10; 5 3,0, ,70, ,30, x;.5; 10; x5 5,500, ,535, x; x.5; x10; x5 x 3,0 x, RCU30ATHYZ1 RCU00ATHYZ1 Main (AC 3) 30, 15V / 50Hz, Control (AC 1) 0, 0V / 50Hz 1,110 1, ,00 95, , ,30,00 13,0(min.),900 +,5 x, x 1 5,50 5,50 Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve NOTES: 1. The nominal cooling capacities are based on the following conditions: *1 Chilled Water Inlet/Outlet Temperature 1 C/7 C Condenser Temperature 35 C (DB) * Chilled Water Inlet/Outlet Temperature 1 C/7 C Condenser Temperature C (DB).The units greater than 0ATHYZ1 including 0ATHYZ1 consist of two modules and are separately shipped.(*). The coon chilled water piping (Filed-Supplied) between each water cooler shall be directly connected at site. 3. Water Flow 1) RCU0,300,30,00ATHYZ1 It is necessary to control the coon water flow volume to each cooler. ) RCU70,330,350,30ATHYZ1 The chilled water flow rate is different between No.1 & No. units. It is necessary to control the water flow volume of each unit with adjusting valves (Filed-Supplied).. It is required to connect electrical control wires between No.1&No. units for the unit greater than 0ATHYZ1 including 0ATHYZ1. 5. ( )marked with *3 is available by selection switch.. Companion flanges are factory supplied. 7. Counication adapter connecting the unit to BMS (Building Management System) is an optional accessory, please contact with HITACHI or HITACHI distributor if required. For the details, please refer to Technical Catalog. With 1 Inner Diameter Companion Flange x 500 x 10 x; x.5; x10; x5 5, ,500 x 5,535 x,00 x, Working Range Item Chilled Water Outlet Temperature Condenser Air Inlet Temperature (DB) Standard 5~10 C 5~5 C Options Heat Recovery System Separate LCD Control Panel

10 Dimensional Data R07C RCUG0,50,0 and 75ATHYZ1 RCU0,50,0 and 75ATHYZ1 (Unit: ) (,390) 90,100 Air Discharge Electric Control Box Water Outlet Temperature (With 90 Inner Diameter Flange) Screw Type Compressor Earth Connection Terminal M , Water Inlet Temperature (With 90 Inner Diameter Flange) Rigging holes(-50) MountingHoles(-) (1,95) 5.5 Chilled water outlet Chilled water inlet, Wiring Hole for Power Supply ,110 Fan 1. It should surpport the water pipings properly to avoid its weight press on the unit directly.. Water connection flanges (90 inner diameter) are supplied by factory with the unit. R07C RCUG100, 10 and 150ATHYZ1 RCU100, 10 and 150ATHYZ1 (Unit: ) (,90),00 Air Discharge Earth Connection Terminal M ,950 Screw Type Compressor Electric Control Box Water Outlet Temperature (With 1 Inner Diameter Flange) Water Inlet Temperature (With 1 Inner Diameter Flange) 1, (1,95) Rigging holes(-50) MountingHoles(-) Wiring Hole for Power Supply Chilled water outlet Chilled water inlet 1,10, Fan, It should surpport the water pipings properly to avoid its weight press on the unit directly.. Water connection flanges (1 inner diameter) are supplied by factory with the unit. R07C RCUG10,10 and 00ATHYZ1 RCU10,10 and 00ATHYZ1 (Unit: ) (,590) 1,900 90,300 Air Discharge Electric Control Box Water Outlet Temperature (With 1 Inner Diameter Flange) 5 Earth Connection Terminal M Screw Type Compressor Water Outlet Water Inlet 1,950,100 1,950 Water Inlet Temperature (With 1 Inner Diameter Flange) (1,95) 5.5,050 Rigging holes(-50) MountingHoles(-) Chilled water outlet 3,15,150 Chilled water inlet Fan 500 Wiring Hole for Power Supply 1. It should surpport the water pipings properly to avoid its weight press on the unit directly.. Water connection flanges (1 inner diameter) are supplied by factory with the unit. 9

11 R07C RCUG0, 70 and 300ATHYZ1 RCU0, 70 and 300ATHYZ1 (Unit: ) 9,00 (,90), (min.) (,90),00 Air Discharge Electric Control Box Earth TerminalM10 Screw Compressor 1, Earth TerminalM10 1,950 1,950 5 Chilled Water Outlet With1Inner Diameter Flange Chilled Water Inlet With1Inner Diameter Flange (1,95) 5.5,050 Rigging holes (-50) MountingHoles (1-) Wiring Hole for Power Supply ,10 No.1 water outlet No.1 water Inlet No. water outlet,090,10,090 No. water Inlet Fan NOTES: 1. This chiller consists of unit No.1 and No. and should be separately shipped.. Support the water pipes with stay not to give the weight of water pipes directly to the unit. 3. Provide a field-supplie coon water piping at the water coolers to connect unit No.1 and No.. Furthermore, for RCU(G)0, 300ATHYZ1: as the No.1 unit and No. unit have a same water rate, it just needs to control the coon water volume to the chiller; for RCU(G)70ATHYZ1: because the chilled water flow rate between No.1 and No. unit is different, It is necessary to control the water volume of each unit with adjusting valves.. It needs to field-connect the control wiring between the No.1 unit and No. unit. R07C RCUG330 and 350ATHYZ1 RCU330 and 350ATHYZ1 (Unit: ) 11,10 90 (,90),00, (min.) 90 Air Discharge Electric Control Box 5 Earth TerminalM ,950,100 Earth TerminalM10 Screw Compressor 1, ,950 1,950 Chilled Water Outlet With1Inner Diameter Flange Chilled Water Inlet With1Inner Diameter Flange Rigging holes (-50) MountingHoles (1-) (1,95) 5.5, Wiring Hole for Power Supply No.1 water outlet No.1 water Inlet No. water outlet 3,15,150,10, No. water Inlet Fan NOTES: 1. This chiller consists of unit No.1 and No. and should be separately shipped.. Support the water pipes with stay not to give the weight of water pipes directly to the unit. 3. Provide a field-supplie coon water piping at the water coolers to connect unit No.1 and No.. Furthermore, for RCU(G)330, 350ATHYZ1, because the chilled water flow rate between No.1and No. unit is different, It is necessary to control the water volume of each unit with adjusting valves.. It needs to field-connect the control wiring between the No.1 unit and No. unit. 5. The dimension marked with P of No. unit is 300. R07C RCUG30, 30 and 00ATHYZ1 RCU30, 30 and 00ATHYZ1 (Unit: ) (,590) 90,300 13,0 100(min.) (,590), Electric Control Box Air Discharge Earth TerminalM10 Earth TerminalM10 Screw Compressor 1,950,100 1, ,950,100 1,950 5 Chilled Water Outlet With1Inner Diameter Flange Chilled Water Inlet With1Inner Diameter Flange Rigging holes (-50) MountingHoles (1-) (1,95) 5.5, Wiring Hole for Power Supply No.1 water outlet No.1 water Inlet No. water outlet 10 3,15,150,105,150 No. water Inlet Fan NOTES: 1. This chiller consists of unit No.1 and No. and should be separately shipped.. Support the water pipes with stay not to give the weight of water pipes directly to the unit. 3. Provide a field-supplie coon water piping at the water coolers to connect unit No.1 and No.. Furthermore, for RCU(G)30, 00ATHYZ1: as the No.1 unit and No. unit have a same water rate, it just needs to control the coon water volume to the chiller; for RCU(G)30ATHYZ1: because the chilled water flow rate between No.1 and No. unit is different, It is necessary to control the water volume of each unit with adjusting valves.. It needs to field-connect the control wiring between the No.1 unit and No. unit. 10

12 ISO 9001 ISO 1001 Printed in Japan (H) HR-E51Q Apr. 009

The High-efficiency Water-cooled Chiller "H series"

The High-efficiency Water-cooled Chiller H series R07C NEW The High-efficiency Water-cooled Chiller "H series" The Water-cooled chiller "H series" with improved efficiency and functionality by several advanced technology. This series with the world's

More information

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - Nominal Cooling Capacity Range 112 kw to 1,080 kw at 50Hz 32 USRT to 307 USRT at 50Hz 96,320 kcal/h to 928,800 kcal/h at 50Hz 382,000 Btu/h to 3,685,000

More information

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by: Johnson Controls - Hitachi Air Conditioning Manufactured by: Johnson Controls-Hitachi Wanbao Air Conditioning (Guangzhou) Co.,Ltd. Address:No.110.ChengAo East Road, Conghua,Guangzhou City, Guangdong Province,China

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

WATE R -C OOLE D WATE R C H ILLE R S

WATE R -C OOLE D WATE R C H ILLE R S WATE R -C OOLE D WATE R C H ILLE R S R40A / R407C / R Standard Type Heat Recovery Type Brine Type ISO 900 ISO 400 Printed in Japan (H) HR-E590S Sep. 0 Water-cooled Chillers Advanced air conditioning solutions

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated. NOMENCLATURE INTRODUCTION The HTT HWDX water-cooled chillers range is the latest addition to HTT s growing family of commercial products, featuring the most current technologies advances. The HWDX main

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

Water chillers water/water type SIGMA Technical information manual

Water chillers water/water type SIGMA Technical information manual Water chillers water/water type SIGMA Technical information manual 2 INDEX Technical features 1 Versions 3 Accessory versions 4 Technical data 7 Electrical data 11 Cooling capacity 12 Heating capacity

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING 171 water cooled chillers / heat pumps and motoevaporating units COOLING HEATING R410A 1 96 3 2 0 1 3 f i f t y c o o l y e a r s RCGROUP SpA 19632013 fiftycoolyears PLATE 5,4 30,5 kw 6,4 37,4 kw 172 VERSIONS

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

Introduction of Hanbell and

Introduction of Hanbell and Introduction of Hanbell and RC2 Series Screw Compressor Jude Chen April 2, 2007 Content 1.Hanbell Company Profile 2.Hanbell Machinery & Production 3.Basic Mechanism of Hanbell Screw Compressor 4.Hanbell

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons n Mission Critical Cooling n Central Plant Process Cooling n Specialized HVAC Cooling Systems COOLING SOLUTIONS

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

DAIKIN Huizhou Factory Profile

DAIKIN Huizhou Factory Profile DAIKIN Huizhou Factory Profile DAIKIN AIR-CONDITIONING (SHANGHAI)CO.,LTD HUIZHOU FACTORY The manufacture base of central air-conditioner in China Established Daikin group, a wholly owned subsidiary Amalgamated

More information

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140

More information

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM

More information

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz Product Catalogue CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to Tons Models: 50 / 60 Hz CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD July 2012 CG-PRC002E-EN Introduction IMPORTANT:

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

Energy-Saving Industrial Water Chillers

Energy-Saving Industrial Water Chillers Energy-Saving Industrial Water Chillers Cycling operation saves power Large storage reservoir Stainless steel pump Microprocessor controls MPC Industrial Water Chillers Motivair is a world-class supplier

More information

500 EX Fusion Compressor Series

500 EX Fusion Compressor Series 500 EX Fusion Compressor Series R404A M/T R404A L/T Capacity RANGE 13.8kW - 20.4kW 7.7kW -11.2kW Copeland Fusion Semi-Hermetic Horizontal Scroll Compressors For Medium and Low Temperature Applications

More information

ROOFTOP PACKAGED AIR CONDITIONERS

ROOFTOP PACKAGED AIR CONDITIONERS ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

Hitachi Air Conditioning. Engineering for tomorrow. And the tomorrow after that. Compact Chillers. Solutions for Industry and Commerce.

Hitachi Air Conditioning. Engineering for tomorrow. And the tomorrow after that. Compact Chillers. Solutions for Industry and Commerce. Hitachi Air Conditioning Engineering for tomorrow. And the tomorrow after that. Compact Chillers Solutions for Industry and Commerce Series Hitachi air conditioning systems: Quality, efficiency and longevity

More information

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview Product overview 1 Company Profile Yantai Oceanair Refrigeration & Air-Conditioning Co.,Ltd. was established in 2004 and has been listed on the New OTCBB (Stock Code: 831870). We are mainly specialized

More information

ARV.

ARV. ARV www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R134a...pag. 5 Semi-hermetic screw compressor...pag.

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP 2 AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP Description of the Unit: The air conditioning unit with an integrated reversible heat pump is a variant

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

RECORD SUBMITTAL COVER SHEET

RECORD SUBMITTAL COVER SHEET RECORD SUBMITTAL COVER SHEET PROJECT TITLE: AXCELLERATE PHARMA EQUIPMENT DESCRIPTION: CARRIER AQUASNAP AIR-COOLED CHILLER CH-1 OWNER: AXCELLERATE PHARMA MECHANICAL ENGINEER: ARDEN DATE: JUNE 27, 2014 SUBMITTED

More information

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to 1.99 kw Centrifugal compressor with magnetic levitation This is a miniaturized, highly innovative

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

Water-Cooled Dual Compressor Screw Chiller

Water-Cooled Dual Compressor Screw Chiller Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,

More information

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X EPCE00-10B Powerful air cooled Hydronic systems EUWA*40-200K(A)X Development Environment Technology 2 Daikin s pre-eminent position in air conditioning and chiller production has been built on over 70

More information

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e. ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

Rotary type Oil-free Air Compressor General Catalogue. Oil-free Scroll Air Compressor Oil-free Claw Air Compressor

Rotary type Oil-free Air Compressor General Catalogue. Oil-free Scroll Air Compressor Oil-free Claw Air Compressor Rotary type Oilfree Air Compressor General Catalogue Oilfree Scroll Air Compressor Oilfree Claw Air Compressor Quiet & Compact, Simple Air Quietness Easy operation Cleanness The scroll mechanism ensures

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Call us today! (800)

Call us today! (800) PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

EN aquatech.piovan.com

EN aquatech.piovan.com EN aquatech.piovan.com Refrigeration Technologies: scroll-compressor chillers The scroll compressor is the most suitable component for the small and medium duty requirements in the industrial applications.

More information

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series 10 3000 SCFM REFRIGERATED COMPRESSED AIR DRYERS CRN Series Durability Delivered Champion CRN Series refrigerated air dryers are engineered to benefit you today and tomorrow. Quality components and engineering

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series NON-CYCLING REFRIGERATED AIR DRYERS RNC Series Durability Delivered Gardner Denver RNC Series refrigerated air dryers are engineered to benefit you today and tomorrow. Quality components and engineering

More information

KCS-Line Air Cooled Condensers

KCS-Line Air Cooled Condensers PRODUCT DATA & INSTALLATION Bulletin K50-KCS-PDI-5 Part # 1085695 PRODUCT SUPPORT web: k-rp.com/kcs email: acc-fc@k-rp.com call: 1-844-893-3222 x526 scan: KCS-Line Air Cooled Condensers R407A R407C R448A

More information

Air-to-water scroll chillers

Air-to-water scroll chillers Air-to-water scroll chillers Model CGA 040 to 115 Cooling capacity: 14-40 kw CG-PRC031B-GB Table of Contents Technical specifications...4 Standard configuration... 4 Hydraulic version... 4 Casing... 4

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES Water to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw Water-Cooled Screw Compressor Liquid Chillers Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 0HC - 50 HZ Nominal

More information

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder. W1860BE.book Page 12 Tuesday, January 28, 2003 11:01 PM 2. Cooling System A: COMPRESSOR The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder. As the rotor

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

T P A 120 S 4 S N 1 Y

T P A 120 S 4 S N 1 Y PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS TP T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TPA-090-120 (11/2012) EER up to 11.0 7.5 to 10 Tons Cooling Capacity - 89,000 to 180,000 Btuh Heating

More information

High-Performance, High-Reliability Gas Heat Pump

High-Performance, High-Reliability Gas Heat Pump 62 High-Performance, High-Reliability Gas Heat Pump Hideaki Kasahara* 1 Atsushi Yoshimura* 1 Ryuuji Morishima* 2 Hisao Iwata* 2 In order to response to annually increasing customer needs for economic efficiency

More information

RNC Series SCFM Global Air Treatment

RNC Series SCFM Global Air Treatment RNC Series 10 3000 SCFM Global Air Treatment 2 Durability Delivered Air Treatment Systems RNC Series refrigerated air dryers are engineered to benefit you today and tomorrow from the tradition of durability

More information

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water. Temperature Control Units Water & Oil 30-500 F Portable Chillers Air & Water-Cooled 20-70 F Central Chillers Air & Water-Cooled Packages & Modules 20-70 F Pump Tank Stations Chilled or Tower Water 200-3600

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

30HX GLOBAL CHILLER LIQUID CHILLER IN HARMONY WITH THE ENVIRONMENT

30HX GLOBAL CHILLER LIQUID CHILLER IN HARMONY WITH THE ENVIRONMENT GLOBAL CHILLER TM LIQUID CHILLER 30HX IN HARMONY WITH THE ENVIRONMENT GLOBAL CHILLER 30HX ADVANCED ULTIMATE RELIABILITY COMPACT SIZE - HIGH PERFORMANCE PRO More than 50000 Carrier screw compressors sold

More information

MODULAR CHILLER. R410a R22

MODULAR CHILLER. R410a R22 Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1. Thomas J Kelly Sr. Engineering Instructor Carrier Corporation August 20, 2003 1 SESSION OBJECTIVES At the conclusion of this session you should be able to: 1. Describe the basics principles of refrigeration

More information

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer Introduction By Timothy J. Fox, P.E. Hankison, an SPX Brand Canonsburg, Pennsylvania Refrigerated

More information

AIR COOLED PACKAGED CHILLER

AIR COOLED PACKAGED CHILLER AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Hi-Pres Cooling Products Catalogue. Product Catalogue

Hi-Pres Cooling Products Catalogue. Product Catalogue Hi-Pres Cooling Products Catalogue Product Catalogue Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product

More information

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS PRODUCT SPECIFICATIONS CONDITIONERS TS T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TSA-072-240 (11/2016) 072-090 Models 180-240 Models 120-150 Models EER up to 11.7 6 to 20 Tons Cooling Capacity

More information

SECTION AIR COOLED WATER CHILLERS

SECTION AIR COOLED WATER CHILLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2

More information

Water-cooled screw chillers. Installation, Operation and Maintenance Manual D 806 C 07/02 F EN

Water-cooled screw chillers. Installation, Operation and Maintenance Manual D 806 C 07/02 F EN Installation, Operation and Maintenance Manual D 806 C 07/02 F EN Water-cooled screw chillers EWWD170-600DJYNN EWWD190-650DJYNN/A 50Hz Refrigerant: R-134a D 806 C 07/02 F EN pag. 1/28 Introduction Purpose

More information

RNC Series SCFM Global Air Treatment

RNC Series SCFM Global Air Treatment RNC Series 10 3000 SCFM Global Air Treatment 2 Durability Delivered Air Treatment Systems RNC Series refrigerated air dryers are engineered to benefit you today and tomorrow from the tradition of durability

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER 30G - 50 Hz Nominal cooling capacity 384-03 kw The 30G units are air-cooled chillers, designed from the ground up to meet the needs of today and

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

LMF Rotary Screw Air Compressors kW LX Range

LMF Rotary Screw Air Compressors kW LX Range LMF Rotary Screw Air Compressors 5.5-400kW LX Range OUR SOLUTIONS ARE YOUR BENIFITS Optimized package design Company Profile LMF is an Austrian manufacturer of reciprocating and rotary screw air and gas

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons Product Data 07DA, DB 07EA, EB, ED Condensing Units 3 to 40 Nominal Tons 06D, 06E Compressors An excellent choice for your built-up system Carrier 07 Series condensing units built for the engineer who

More information

Presented By: John Dolan, P.E.

Presented By: John Dolan, P.E. Variable Speed Compressor Technologies Presented By: John Dolan, P.E. President - Thermosystems, Inc. BS in Mechanical Engineering from UIUC 29 years HVAC Equipment Application Experience jdolan@thermohvac.com

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz Product Data GEMINI SELECT 09DPS018-030,09DPM035-130 Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz 18 to 130 Nominal Tons (63 to 457 Nominal kw) a38-7096 09DPS030 UNIT WITH LOW SOUND OPTION

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water

More information