1 ESP Series MEDICAL ELECTRICAL ACCESSORIES AND MEDICAL SERVICE PANELS clipsal.com/cis

2

3 Contents Introduction 2-3 ESP Series THE PROVEN PERFORMER 4 AS/NZS3003 Electrical Installations PATIENT TREATMENT AREAS 5 Medical Service Panel Systems 6-9 SURFACE MOUNT 6 FLUSH MOUNT 7 SURFACE MOUNT DUCT 8 PANEL MOUNT 9 Medical Service Panel Electrical Accessories COMBINATION RCD/MCB 10 AUDIBLE ALARM 12 LINE ISOLATION & OVERLOAD MONITOR (LIOM) AND ISOLATION TRANSFORMER 14 EQUIPOTENTIAL JUNCTION 20 SOCKET OUTLETS 22 ACCESSORIES Combination RCD Relay/Circuit Breakers and Accessories Portable RCD/MCB Protected Power Outlets 34 Test Equipment 35 Area Classification Signs 36 Educational Videos 37 Technical Information WHY IS THERE A NEED FOR SPECIAL ELECTRICAL INSTALLATIONS 38 AREA CLASSIFICATION AND REQUIREMENTS 40 RCD FUNCTIONAL DESCRIPTION 41 LINE ISOLATION AND OVERLOAD MONITOR FUNCTIONAL DESCRIPTION 42 EQUIPOTENTIAL EARTHING FUNCTIONAL DESCRIPTION 43 CHOOSING BETWEEN AN RCD OR LIOM 44

4 Introduction Hospitals have undergone a dramatic transformation in the past 20 years. More and more electrical medical equipment is now used in patient treatment areas of hospitals and medical practices. With the increase in the amount of equipment comes the increase risk of electrocution. As a result, electrocution protection equipment is now a common requirement in almost every area of the hospital and medical practice. The Electronic Safety Product range of electrocution protection equipment has been around since the introduction of electrical safety and the product range still continues today. Over the years the product range has proven its reliability and continues to meet the requirements of hospital electrical installations today.

5

6 The Proven Performer THE PROVEN PERFORMER Before becoming part of Clipsal Integrated Systems, the company Electronic Safety Products (ESP), was one of Australia s leading designers and manufacturers of equipment which provides a high level of protection against electrocution. Since the 1970s ESP was involved with the design, development and manufacture of Residual Current Devices (RCDs), Line Isolation and Overload Monitors (LIOMs), and Medical Service Panels suitable for use in patient treatment areas. The ESP product range and expertise continues within Clipsal Integrated Systems and now comprises of a range of electrocution protection equipment, various styles of Medical Service Panel Systems, and a large range of accessories specifically developed to meet the requirements of patient treatment areas of hospitals. ESP SERIES 4

7 AS/NZS3003. ELECTRICAL INSTALLATIONS: PATIENT TREATMENT AREAS OF HOSPITALS AND MEDICAL AND DENTAL PRACTICES The ESP Series product range is designed to meet the requirements of AS/NZS3003. AS/NZS3003 sets out the specialist electrical installation requirements often found in the following premises. Hospitals Medical Practices Dental Practices Physiotherapy Practices The areas within these premises that would need to meet AS/NZS3003 are classified as Body or Cardiac Protected Areas. The procedures carried out to classify these areas as Body or Cardiac Protected are as follows: Within Body Protected Areas procedures are carried out where a patient is connected to an item of electro-medical equipment which reduces the impedance of the skin by either electrode paste or by the entrance of conducting fluids, metal needles, saline filled catheters etc. ELECTRICAL I N S T A L L A T I O N S Within Cardiac Protected Areas the same procedures are carried out as in the Body Protected Areas but also procedures where a patient has an electrical conductor placed within the heart or is likely to come into contact with the heart eg. electrical wires such as cardiac pacing electrodes and intracardiac ECG electrodes, or insulated tubes filled with conducting fluids. PATIENT TREATMENT AREAS 5

8 Medical Service Panel Systems SURFACE MOUNT MEDICAL SERVICE PANEL SYSTEMS Medical Service Panels (MSPs) provide access to power, data, nurse call, hospital gas and environmental controls in patient areas of hospitals and medical practices. The Surface Mount MSP system is typically used in areas of a hospital where an MSP incorporating a limited number of accessories is required to be mounted to a wall that is not easily suited to the installation of a recessed wall box. An example of this would be in a refurbishment of an existing area within a hospital where the walls are of brick construction. Features Incorporates a fascia and surface mount box that is directly mounted to the face of the wall Accessories are typically mounted directly to the fascia Standard finish is stainless steel but can be powdercoated upon request Available in four sizes (see table) SIZE DIMENSIONS 1 or 2 modules 220mm(h) x 175mm(w) x 90mm(d) 3 or 4 modules 220mm(h) x 275mm(w) x 90mm(d) 5 or 6 modules 220mm(h) x 425mm(w) x 90mm(d) SURFACE MOUNT 7 or 8 modules 220mm(h) x 525mm(w) x 90mm(d) *An electrical accessory is typically 1 module wide. 6

9 Medical Service Panel Systems FLUSH MOUNT Medical Service Panels (MSPs) provide access to power, data, nurse call, hospital gas and environmental controls in patient areas of hospitals and medical practices. The Flush Mount MSP system is typically installed in critical areas of the hospital where a strong and reliable product is required. These areas are operating theatres and other high dependency areas. Features Incorporates a flush mount fascia that fits to a recessed wall box Accessories are typically mounted directly to the fascia Wall box incorporates height adjusters to allow the wall box to be roughly fitted then adjusted to sit flush with the front face of the wall Standard finish is stainless steel but can be powdercoated upon request Available in four sizes (see table) MEDICAL SERVICE PANEL SYSTEMS SIZE DIMENSIONS 1 or 2 modules Fascia 220mm(h) x 175mm(w) Wall box (cat no. WB2) 198mm(h) x 150mm(w) x 70mm(d) 3 or 4 modules Fascia 220mm(h) x 275mm(w) Wall box (cat no. WB4) 198mm(h) x 250mm(w) x 70mm(d) 5 or 6 modules Fascia 220mm(h) x 425mm(w) Wall box (cat no. WB6) 198mm(h) x 400mm(w) x 70mm(d) 7 or 8 modules Fascia 220mm(h) x 525mm(w) Wall box (cat no. WB8) 198mm(h) x 500mm(w) x 70mm(d) FLUSH MOUNT *An electrical accessory is typically 1 module wide. 7

10 Medical Service Panel Systems SURFACE MOUNTED DUCT MEDICAL SERVICE PANEL SYSTEMS Medical Service Panels (MSPs) provide access to power, data, nurse call, hospital gas and environmental controls in patient areas of hospitals and medical practices. The Surface Mounted Duct MSP system is primarily used in areas of a hospital where long lengths of medical service panels are required. The advantages of a surface mount system over a flush mount system is that there is less internal wall preparation required because the wall does not need to be modified to accommodate recessed wall boxes or modified to accommodate long runs of wiring and gas piping. Features Unlimited MSP length Incorporates 3 segregation service channels so all services can run within the trunking instead of the walls Square cross section so it can be neatly mounted underneath a shelf The panels are available in stainless steel or powdercoated finish, with the trunking available in a powdercoated finish FASCIA SIZE DIMENSIONS DUCTING SIZE DIMENSIONS 1 or 2 modules 221mm(h) x 100mm(w) Aduct 232mm(h) x 130mm(d) SURFACE MOUNTED DUCT 3 or 4 modules 221mm(h) x 200mm(w) *An electrical accessory is typically 1 module wide. 8

11 Medical Service Panel Systems PANEL MOUNT Medical Service Panels (MSPs) provide access to power, data, nurse call, hospital gas and environmental controls in patient treatment areas of hospitals and medical practices. The Panel Mount system is typically supplied to alternative MSP manufacturers so they can incorporate them into their own MSPs. The Panel Mount system comprises of the modular ESP electrical accessories fitted to a fascia mounting frame. Features Incorporates modular rectangular electrical accessories for easy fascia manufacture Electrical accessories are pre-wired to common terminal blocks for easy installation Mounting frames available in two sizes E01/10/4 MEDICAL SERVICE PANEL SYSTEMS SIZE DIMENSIONS 1 or 2 modules 95mm(h) x 198mm(w) x 65mm(d) 3 or 4 modules 190mm(h) x 198mm(w) x 65mm(d) *An electrical accessory is typically 1 module wide. PANEL MOUNT 9

12 Combination RCD/MCB E01CNN SERIES The E01 Series combination RCD/MCBs provide electrocution and overload protection as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES This product is available as an individual module or incorporated within the four different styles of ESP Series Medical Service Panels (MSPs). Features 10mA trip current Overload protection Blue Line Supply Indicator & Amber Load Supply Indicator In-built indicator to indicate whether an RCD or MCB fault has occurred In-built test facility Modular DIN rail mounted design E01CNN10 Sophisticated filtering to stop nuisance tripping caused by Radio Frequency Interference (RFI) CAT NO. E01CNN* E01/*/1 DESCRIPTION RCD/MCB Module Surface Mount RCD/MCB COMBINATION RCD/MCB E01/*/2 E01/*/3 E01/*/4 Flush Mount RCD/MCB Duct Mount RCD/MCB Panel Mount RCD/MCB Note Replace * within the catalogue number with either 10, 16, 20, or 32 depending on the overload rating. If Flush Mounted then the corresponding recessed wall box is Cat No. WB2. Wiring Diagram 10

13 E01/10/1 E01/10/2 MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES E01/10/3 E01/10/4 SPECIFICATIONS Trip Current Trip Time Operational Voltage Overload Rating Operating Temp. Standard Finishes Dimensions 10mA < 40ms 240V a.c. 50Hz 10, 16, 20, or 32 Amp -10ºC to +55ºC Module WE White Electric Surface Mount stainless steel Flush Mount stainless steel Duct Mount powdercoated (Sand) Module 74mm(h) x 45mm(w) x 65mm(d) Surface Mount 220mm(h) x 175mm(w) x 90mm(d) Flush Mount 220mm(h) x 175mm(w) x 70mm(d) Duct Mount 221mm(h) x 100mm(w) x 70mm(d) Panel Mount - 198mm(h) x 95mm(w) x 70mm(d) COMBINATION RCD/RCB 11

14 Audible Alarm MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES E08M SERIES The E08M Series Audible Alarm is used in conjunction with the E01 Series combination RCD/MCB. It is used to provide audible and visual indication of when the RCD it is monitoring, trips. The E08M Series Audible Alarm is available as an individual module or is combined with the E01 Series combination RCD/MCB and incorporated within the four different styles of ESP Series Medical Service Panels (MSPs). Features Multiple 2 tone audible indication Flashing red visual alarm indicator Mute push-button marked PRESS TO MUTE Remote alarm contacts Modular DIN rail mounted design E08M CAT NO. E08M E02/*/1 DESCRIPTION Audible Alarm Module Surface Mount Audible Alarm and combined RCD/MCB AUDIBLE ALARM E02/*/2 E02/*/3 E02/*/4 Flush Mount Audible Alarm and combined RCD/MCB Duct Mount Audible Alarm and combined RCD/MCB Panel Mount Audible Alarm and combined RCD/MCB Note Replace * within the catalogue number with either 10, 16, 20, or 32 depending on the RCD/MCB overload rating. If Flush Mounted then the corresponding recessed wall box is Cat No. WB2. Wiring Diagram 12

15 E02/10/1 E02/10/2 MEDICAL SERVICE PANEL ACCESSORIES E02/10/3 E02/10/4 SPECIFICATIONS Operational Voltage Remote Alarm Contacts Trip Current (RCD/MCB only) Trip Time (RCD/MCB only) Overload Rating (RCD/MCB only) Operating Temp. Standard Finishes Dimensions 240V a.c. 50Hz Volt free, changeover, 5A/240V relay contacts 10mA < 40ms 10, 16, 20, or 32 Amp -10ºC to +55ºC Module WE White Electric Surface Mount stainless steel Flush Mount stainless steel Duct Mount powdercoated (Sand) Module 74mm(h) x 45mm(w) x 65mm(d) Surface Mount 220mm(h) x 175mm(w) x 90mm(d) Flush Mount 220mm(h) x 175mm(w) x 70mm(d) Duct Mount 221mm(h) x 100mm(w) x 70mm(d) Panel Mount - 198mm(h) x 95mm(w) x 70mm(d) AUDIBLE ALARM 13

16 Line Isolation & Overload Monitor (LIOM) E05 SERIES MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES The E05 Series Line Isolation and Overload Monitor in conjunction with the E14 Series Isolation Transformer, form the basis of an isolated supply system which provides electrocution and overload protection as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. The E05 Series LIOM is available in the four different styles of ESP Series Medical Service Panels (MSPs). Features 5mA Prospective Hazard Current (PHC) Alarm Point 1 to 9mA Prospective Hazard Current LCD Display Visual PHC Alarm, Overload Alarm, and Alarm Muted LED indication Mutable 2 tone audible PHC and Overload Warning indication Remote alarm contacts In-built test facility CAT NO. DESCRIPTION LINE ISOLATION & OVERLOAD MONITOR E05/*/1 E05/*/2 E05/*/3 E05/*/4 Surface Mount LIOM Flush Mount LIOM Duct Mount LIOM Panel Mount LIOM Note Replace * within the catalogue number with either 36, 48 or 72 depending on the overload alarm point ie. 36(15A), 48(20A) or 72(30A). If Flush Mounted then the corresponding recessed wall box is Cat No. WB4. 14

17 E05/36/1 E05/36/2 MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES E05/36/3 E05/36/4 SPECIFICATIONS Operational Voltage 240V a.c. 50Hz PHC Display 1 to 9mA LCD PHC Alarm Point 5mA Overload Alarm Point 15A (3.6kVA), 20A (4.8kVA) or 30A (7.2kVA) Audible Alarm 82 db typical at 1 metre Remote Alarm Contacts Volt free, changeover, 5A relay contacts Operating Temp. 10ºC to 35ºC Standard Finishes Surface Mount stainless steel Flush Mount stainless steel Duct Mount powdercoated (Sand) Dimensions Surface Mount 220mm(h) x 275mm(w) x 90mm(d) Flush Mount 220mm(h) x 275mm(w) x 70mm(d) Duct Mount 221mm(h) x 200mm(w) x 70mm(d) Panel Mount - 198mm(h) x 190mm(w) x 70mm(d) LINE ISOLATION & OVERLOAD MONITOR 15

18 Line Isolation & Overload Monitor (LIOM) Operation MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES An isolated supply is a continuous supply. The isolation transformer isolates the power from earth therefore a fault on both lines of secondary transformer winding to earth needs to occur before a fault current flows. A fault on only one line and earth will not cause a fault current to flow. A Line Isolation and Overload Monitor (LIOM) enables the integrity of an isolated power supply system to be continuously monitored. The LIOM is able to detect when one fault occurs therefore is able to warn of a potential hazardous situation before any fault current actually flows. The first fault is know as Prospective Hazard Current (PHC). The LIOM displays the PHC on a LCD bar graph display and when 5mA PHC is reached a mutable alarm sounds along with a flashing LED indicator labelled PHC Warning. If a PHC alarm condition arises, the medical staff can, in the light of the seriousness of the patient s condition, choose to continue with the procedure. In this situation, the surgeon is relying on a second fault not occurring that would turn the PHC into a real flow of current. During this time, measures can be taken to rectify the fault condition by, for example, disconnecting all nonessential equipment. In addition to the LIOM monitoring isolation it also warns of an impending overload, thus averting problems which could result from a loss of supply. When the overload level is reached a mutable alarm sounds along with an Overload Warning flashing LED indicator. LINE ISOLATION & OVERLOAD MONITOR Schematic Diagram 16

19 Installation When installing an isolated supply there are several things to take into consideration. Long runs of cable between the transformer and the LIOM and/or long runs between the LIOM and the outlets should be avoided. Due to capacitive coupling between cables and between cables and conduit, runs longer than 50m can result in high standing PHC (ie;>2ma). Parallel runs of cables from two or more isolated supply systems should also be avoided, The cross talk between parallel cables may cause rhythmic fluctuations on the unit's displays. Where parallel wiring cannot be avoided, wiring should include an earth (eg; TPS). The earth conductor should be earthed only at one end of its run. Whilst running cable in this manner will lessen cross talk problems, it may increase standing PHC. Because the E05 LIOM monitors the load current on line the LIOM must be the first item connected to the secondary winding of the isolation transformer. All items to be powered from the isolated supply must connect back to the terminals of the LIOM labelled Active 1 Out and Active 2 Out. Failure to do this will result in incorrect measurements of the load current. Due to the high inrush current when power is first applied to the isolation transformer a suitable circuit breaker needs to be chosen. It is recommended to use a Heinemann Electric CF Series Circuit Breaker. MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES Wiring Diagram LINE ISOLATION & OVERLOAD MONITOR 17

20 Isolation Transformer E14 SERIES The E14 Series Isolation Transformer in conjuction with the E05 Series Line Isolation and Overload Monitor form the basis of an isolated supply system which provides electrocution and overload protection as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. This product is available in three different versions. The first being the respected E14 version, which for over a decade has been installed into hospitals throughout Australia and the Asia Pacific Region. The remaining two E14/2 and E14/3 versions are an economical alternative to the E14, while still meeting the requirements of the respective standards. Features Steel enclosure. The E14 & E14/2 versions are fully encapsulated in heat cured epoxy resin to reduce noise and prevent ingress of moisture and dust. CAT NO. E14/* E14/*/2 E14/*/3 DESCRIPTION Isolation Transformer - Encapsulated Isolation Transformer - Encapsulated Isolation Transformer - Non Encapsulated Note Replace * within the catalogue number with either 36 (3.6kVA), 48 (4.8vKA) or 72 (7.2kVA) depending on the rating. 18

21 E14/36 E14/36/2 MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES SPECIFICATIONS 3.6kVA 4.8kVA 7.2kVA Input Voltage Output Voltage 240V a.c. 50Hz 240V a.c. +/-2% 50Hz Regulation +/-3% Current Rating 15A 20A 30A No Load Current 1.0 Amp max 2.0 Amp max 2.0 Amp max (0.5 Amp typical) (1.0 Amp typical) (1.0 Amp typical) Max Ambient Temp 45ºC (cas may exceed 100ºC on full load) Weight E E14/*/ E14/*/ Dimensions (mm): E x 270 x x 270 x x 430 x 400 (H x W x D) E14/*/2 225 x 300 x x 300 x x 300 x 280 E14/*/3 225 x 300 x x 300 x x 300 x 280 Construction: E14 Cased in steel enclosure and fully encapsulated in heat cured expoxy resin. E14/*/2 Cased in steel enclosure and fully encapsulated in heat cured expoxy resin. E14/*/3 Cased in ventilated steel enclosure. ISOLATION TRANSFORMER 19

22 Equipotential Junction E34 AND E35 SERIES MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES The E34 and E35 Series Equipotential Junctions (EPJ) form part of the Equipotential Earthing System which provides micro electrocution protection in cardiac protected areas as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. The EP Earthing system requires all earthed points within the cardiac protected area to be connected back to a common EP Junction via low resistance earth wiring (large cross section). The low resistance system reduces the potential difference between two earthed points in the area therefore reducing the risk of micro electrocution from the stray currents flowing in the earthing system. The E34 and E35 Series EPJ is available in the four different styles of ESP Series Medical Service Panels (MSP). Features 1 x BP25 line tap for bus termination 4 x 5mm diameter termination tunnels (E34) 4 x 8mm and 10 x 5mm diameter termination tunnels (E35) 1 x EP stud for testing Labelled EQUIPOTENTIAL JUNCTION CAT NO. DESCRIPTION E34/1 Surface Mount EPJ E35/1 Surface Mount EPJ EQUIPOTENTIAL JUNCTION E34/2 Flush Mount EPJ E35/2 Flush Mount EPJ E34/3 Duct Mount EPJ E35/3 Duct Mount EPJ E34/4 Panel Mount EPJ E35/4 Panel Mount EPJ Note If Flush Mounted then the corresponding recessed wall box is Cat No. WB2 for E34 and WB4 for E35. 20

23 E34/1 E34/2 MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES E34/3 E34/4 SPECIFICATIONS Standard Finishes Dimensions Surface Mount stainless steel Flush Mount stainless steel Duct Mount powdercoated (Sand) E34 Surface Mount 220mm(h) x 175mm(w) x 90mm(d) Flush Mount 220mm(h) x 175mm(w) x 70mm(d) Duct Mount 221mm(h) x 100mm(w) x 70mm(d) Panel Mount - 198mm(h) x 95mm(w) x 70mm(d) E35 Surface Mount 220mm(h) x 275mm(w) x 90mm(d) Flush Mount 220mm(h) x 275mm(w) x 70mm(d) Duct Mount 221mm(h) x 200mm(w) x 70mm(d) Panel Mount - 198mm(h) x 190mm(w) x 70mm(d) EQUIPOTENTIAL JUNCTION 21

24 Socket Outlets - M Style E015VDN SERIES There are two styles of socket outlets within the ESP Series. One of these is the modular M style. CAT NO. DESCRIPTION MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES This product is available as an individual module or incorporated within the four different styles of ESP Series Medical Service Panels (MSPs). Features Moulded in chemically resistant Valox Double pole switching Safety shutters Red switched power neon 10A or 15A Modular DIN rail mounted design E015VDN E015VDN15 G01M1 G02M1 G03M1 G04M1 G05M1 G06M1 G07M1 G08M1 G01M2 G02M2 G03M2 Socket Outlet Module 10A Socket Outlet Module 15A Surface Mount 1 Outlet Surface Mount 2 Outlet Surface Mount 3 Outlet Surface Mount 4 Outlet Surface Mount 5 Outlet Surface Mount 6 Outlet Surface Mount 7 Outlet Surface Mount 8 Outlet Flush Mount 1 Outlet Flush Mount 2 Outlet Flush Mount 3 Outlet G04M2 Flush Mount 4 Outlet G05M2 Flush Mount 5 Outlet G06M2 Flush Mount 6 Outlet G07M2 Flush Mount 7 Outlet G08M2 Flush Mount 8 Outlet G01M3 Duct Mount 1 Outlet G02M3 Duct Mount 2 Outlet G03M3 Duct Mount 3 Outlet G04M3 Duct Mount 4 Outlet SOCKET OUTLETS E015VDN G01M4 G02M4 G03M4 G04M4 Panel Mount 1 Outlet Panel Mount 2 Outlet Panel Mount 3 Outlet Panel Mount 4 Outlet Note If the switched sockets are powered from a remotely mounted RCD then an amber power available neon will need to be added to the MSP. If Flush Mounted, then the corresponding recessed wall box is Cat No. WB2 (1 or 2 outlets), WB4 (3 or 4 outlets), WB6 (5 or 6 outlets), WB8 (7 or 8 outlets). 22

25 G04M1 G04M3 G04M2 G04M4 MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES SPECIFICATIONS Operational Voltage 240V a.c. 50Hz Max Load 10 or 15 Amps (Standard MSP fitted with 10A) Spacing MSP outlets spaced 45mm between centres Standard Finishes Socket Outlet WE White Electric Surface Mount stainless steel Flush Mount stainless steel Duct Mount powdercoated (Sand) Dimensions Module 74mm(h) x 45mm(w) Surface Mount (1 or 2 outlet) 220mm(h) x 175mm(w) x 90mm(d) (3 or 4 outlet) 220mm(h) x 275mm(w) x 90mm(d) (4 or 6 outlet) 220mm(h) x 425mm(w) x 90mm(d) (7 or 8 outlet) 220mm(h) x 525mm(w) x 90mm(d) Flush Mount (1 or 2 outlet) 220mm(h) x 175mm(w) x 70mm(d) (3 or 4 outlet) 220mm(h) x 275mm(w) x 70mm(d) (5 or 6 outlet) 220mm(h) x 425mm(w) x 70mm(d) (7 or 8 outlet) 220mm(h) x 525mm(w) x 70mm(d) Duct Mount (1 or 2 outlet) 221mm(h) x 100mm(w) x 70mm(d) (3 or 4 outlet) 221mm(h) x 200mm(w) x 70mm(d) Panel Mount (1 or 2 outlet) - 198mm(h) x 95mm(w) x 70mm(d) (1 or 2 outlet) - 198mm(h) x 190mm(w) x 70mm(d) SOCKET OUTLETS 23

26 Socket Outlets - O Style ABC SERIES There are two styles of socket outlets within the ESP Series. One of these is the O style. CAT NO. DESCRIPTION MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES SOCKET OUTLETS This product is available as an individual item or incorporated within three different styles of ESP Series Medical Service Panels (MSPs). Features Double or single pole switching Safety shutters Optional red switched power neon Vertical or horizontal configuration 10A or 15A ABC15VDNMLBLF ABC15VDNMLBLF ABC15VDMLBLF ABC15VNMLBLF ABC15VMLBLF ABC15DNMLBLF ABC15DMLBLF ABC15NMLBLF ABC15MLBLF G01O1 G02O1 G03O1 G04O1 G05O1 G06O1 G07O1 G08O1 G01O2 G02O2 G03O2 G04O2 G05O2 G06O2 G07O2 G08O2 G01O3 G02O3 G03O3 G04O3 Note Socket Outlet, vertical, double pole, neon, 10A Socket Outlet, vertical, double pole, 10A Socket Outlet, vertical, neon, 10A Socket Outlet, vertical, 10A Socket Outlet, horizontal, double pole, neon, 10A Socket Outlet, horizontal, double pole, 10A Socket Outlet, horizontal, neon, 10A Socket Outlet, horizontal, 10A Surface Mount 1 Outlet Surface Mount 2 Outlet Surface Mount 3 Outlet Surface Mount 4 Outlet Surface Mount 5 Outlet Surface Mount 6 Outlet Surface Mount 7 Outlet Surface Mount 8 Outlet Flush Mount 1 Outlet Flush Mount 2 Outlet Flush Mount 3 Outlet Flush Mount 4 Outlet Flush Mount 5 Outlet Flush Mount 6 Outlet Flush Mount 7 Outlet Flush Mount 8 Outlet Duct Mount 1 Outlet Duct Mount 2 Outlet Duct Mount 3 Outlet Duct Mount 4 Outlet If the switched sockets are powered from a remotely mounted RCD then an amber power available neon will need to be added to the MSP. If Flush Mounted then the corresponding recessed wall box is Cat No. WB2 (1 or 2 outlets), WB4 (3 or 4 outlets), WB6 (5 or 6 outlets), WB8 (7 or 8 outlets). 24

27 Socket Outlets - O Style G04O1 MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES G04O2 G04O3 SPECIFICATIONS Operational Voltage 240V a.c. 50Hz Max Load 10 or 15 Amps (Standard MSP fitted with 10A) Spacing MSP outlets spaced 45mm between centres Standard Finishes Socket Outlet - WE White Electric Surface Mount stainless steel Flush Mount stainless steel Duct Mount powdercoated (Sand) Dimensions Surface Mount (1 or 2 outlet) 220mm(h) x 175mm(w) x 90mm(d) (3 or 4 outlet) 220mm(h) x 275mm(w) x 90mm(d) (4 or 6 outlet) 220mm(h) x 425mm(w) x 90mm(d) (7 or 8 outlet) 220mm(h) x 525mm(w) x 90mm(d) Flush Mount (1 or 2 outlet) 220mm(h) x 175mm(w) x 70mm(d) (3 or 4 outlet) 220mm(h) x 275mm(w) x 70mm(d) (5 or 6 outlet) 220mm(h) x 425mm(w) x 70mm(d) (7 or 8 outlet) 220mm(h) x 525mm(w) x 70mm(d) Duct Mount (1 or 2 outlet) 221mm(h) x 100mm(w) (3 or 4 outlet) 221mm(h) x 200mm(w) SOCKET OUTLETS 25

28 Accessories MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES POWER AVAILABLE NEON The N01 Power Available Neon provides line supply power indication to groups of socket outlets mounted remotely from the RCD that they are protected by, as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. This product is available as an individual item or can be incorporated within the three styles of ESP Series Medical Service Panels (MSPs). Features Amber in colour Marked POWER AVAILABLE Fits all Clipsal size mech apertures Supplied with Clipsal F30Z1.5 mounting clip N01 CAT NO. DESCRIPTION SPECIFICATIONS N01 Power Available Neon Operational Voltage 240V a.c. 50Hz Colour ACCESSORIES Amber 26

29 Accessories EQUIPOTENTIAL EARTH STUD The R01 Equipotential Earth Stud provides a means to connect a piece of medical equipment to the Equipotential Earthing System as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. This product is available as an individual item or can be incorporated within the three styles of ESP Series Medical Service Panels (MSPs). Features EP Stud clearly identified in colour green Screw clamping system for effective EP earthing connection R01 MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES CAT NO. DESCRIPTION SPECIFICATIONS R01 Equipotential Earth Stud Colour Green ACCESSORIES 27

30 Accessories MEDICAL SERVICE PANEL ELECTRICAL ACCESSORIES EQUIPOTENTIAL EARTH LEADS The L0 Series Equipotential Earth Leads provide a means to connect a piece of medical equipment to the Equipotential Earthing System via Equipotential Earth Studs, as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. Features Lead clearly identified in colour green Sturdy crimp lug each end of lead L01 CAT NO. DESCRIPTION SPECIFICATIONS L01 Equipotential Earth Lead 1 metre Colour Green L02 Equipotential Earth Lead 2 metre Dimensions 1 to 5 metres in length L03 Equipotential Earth Lead 3 metre L04 Equipotential Earth Lead 4 metre ACCESSORIES L05 Equipotential Earth Lead 5 metre 28

31 Combination RCD Relay/Circuit Breakers E38 SERIES The E38 Series RCDs provide electrocution and optional overload protection as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. The RCD is typically used for high load current or three phase applications, such as protecting x-ray machines etc. This product is available as an individual item or can be mounted within the 3 different styles of ESP Series Medical Service Panels (MSPs). Features 10mA trip current Suitable for single to three phase applications Amber Load Supply Indicator In-built test facility Optional overload protection (max 100A) E38CF4 COMBINATION RCD RELAY/CIRCUIT BREAKERS AND ACCESSORIES CAT NO. DESCRIPTION E38CF2/*A E38CF4/*A E38CF2/*N E38CF3/*N RCD, 2 Pole, Auto RCD, 4 Pole, Auto RCD, 2 Pole, Non Auto RCD, 3 Pole, Non Auto E38CF4/*N Note RCD, 4 Pole, Non Auto Replace * within the catalogue number with either 4, 8, 10, 16, 20, 25, 32, 40, 50, 63, 80, 100 depending on the load rating. An E03TR transformer will also need to be installed if using an E38CF3 Series (3 pole). E38 Series 29

32 Combination RCD Relay/Circuit Breakers SPECIFICATIONS COMBINATION RCD RELAY/CIRCUIT BREAKERS AND ACCESSORIES Trip Current Trip Time Operational Voltage Overload Rating Operating Temp. Maximum Fault Current Standard Colours Dimensions 10mA (other ratings available on request) < 40ms (other rating available on request) 240V a.c. or 415V a.c. 50Hz 4, 8, 10, 16, 20, 25, 32, 40, 50, 63, 80, 100 Amp -10ºC to +55ºC 6.5kA BK Black E38CF2 183mm(h) x 80mm(w) x 72mm(d) E38CF3 183mm(h) x 106mm(w) x 72mm(d) E38CF4 183mm(h) x 131mm(w) x 72mm(d) Wiring Diagram E38 Series 30

33 RCD Relay E03 SERIES The E03 Series RCD Relay when combined with a shunt trip circuit breaker provides electrocution protection as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. The RCD relay combined with a shunt trip circuit breaker is typically used for high load current or three phase applications, such as protecting x-ray machines etc. Features 10mA trip current Suitable for single to three phase applications Amber Load Supply Indicator In-built test facility E03/10/10 COMBINATION RCD RELAY/CIRCUIT BREAKERS AND ACCESSORIES CAT NO. DESCRIPTION SPECIFICATIONS E03/10/10 E03/30/10 Note RCD Relay 10mA 10ms RCD Relay 30mA 10ms An E03TR transformer will also need to be installed if using an E03 in 3 phase (no neutral) applications. Wiring Diagram Trip Current Trip Time Operational Voltage Operating Temp. Load Range (shunt trip coil) Standard Colours Dimensions Hole Dimension 10mA or 30mA < 10ms 240V a.c. 50Hz -10ºC to +55ºC ohms E0 Electric Orange 141mm(h) x 27mm(w) x 72mm(d) ø32mm ACCESSORIES 31

34 RCD Relay Transformer E03TR The E03TR Step Down Transformer is used in conjuction COMBINATION RCD RELAY/CIRCUIT BREAKERS AND ACCESSORIES with the E38 Series Combination RCD Relay/Circuit Breaker or E03 Series RCD Relay in 3 phase (no neutral) applications. The E03 RCD Relay, which is also incorporated within the E38 Series Combination RCD Relay/Circuit Breaker, is rated at 240V a.c. In 3 phase (no neutral) applications where there is only 415V a.c. available the E03TR Step Down Transformer is used to supply 240V a.c. to the E03 RCD Relay. E03TR CAT NO. DESCRIPTION Wiring Diagram E03TR RCD Relay step door transformer 415:240 SPECIFICATIONS ACCESSORIES Input Voltage Output Voltage Dimensions 415V a.c. 50Hz (blue wires) 240V a.c. 50Hz (red wires) 50mm(h) x 85mm(w) x 40mm(d) 32

35 Audible Alarm E08 The E08 Series Audible Alarm is used in conjunction with the E38 Series Combination RCD Relay/Circuit Breaker or E03 Series RCD Relay. It is used to provide audible and visual indication of when the RCD is monitoring trips. Features Multiple 2 tone audible indication Red visual alarm indicator Mute push-button marked PRESS TO MUTE Optional remote alarm contacts E08 COMBINATION RCD RELAY/CIRCUIT BREAKERS AND ACCESSORIES CAT NO. DESCRIPTION SPECIFICATIONS E08 Wiring Diagram Audible Alarm Module Operational Voltage Audible Alarm Remote Alarm Contacts (optional) Standard Colours Dimensions 240V a.c. 50Hz 64 db typical at 1 metre Volt free, changeover, 5A/240V relay contacts E0 Electric Orange 141mm(h) x 27mm(w) x 72mm(d) ACCESSORIES 33

36 Portable RCD/MCB Protected Power Outlets E12 AND E13 The E12 and E13 are portable RCD/MCB protected power outlets that provide electrocution and overload PORTABLE RCD/MCB PROTECTED POWER OUTLETS protection as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. This product is used to temporarily upgrade an unprotected area into a Body Protected Area. Features 10mA trip current Overload protection Amber power available neon 2 (E12) or 4 (E13) outlets 3 metre power cord In-built indicator to indicate whether an RCD or MCB fault has occurred In-built test facility E12 CAT NO. DESCRIPTION SPECIFICATIONS E12 AND E13 E12 E13 Portable RCD/MCB - 2 outlet Portable RCD/MCB - 4 outlet Number of Outlets Trip Current Trip Time Operational Voltage Current Rating Operating Temp. Mains Cord Standard Colours Dimensions 2 (E12) or 4 (E13) 10mA < 40ms 240V a.c. 50Hz 10A (15A optional) -10ºC to +55ºC 3 metres E0 Electric Orange 60mm(h) x 130mm(w) x 120mm(d) 34

37 Line Isolation Monitor Tester - PHC Simulator E15T The E15T Prospective Hazard Current (PHC) Simulator provides a convenient means for basic in-service testing of the Line Isolation Monitor function of the E05 Line Isolation and Overload Monitor (LIOM). The tester incorporates a range of resistive and capacitive impedances that can be connected between each isolated line and earth in various combinations. Features Line 1 and 2 high standing PHC neon indicators Line 1 and 2 capacitive PHC Line 1 and 2 resistive PHC E15T TEST EQUIPMENT CAT NO. DESCRIPTION SPECIFICATIONS E15T LIM Tester Operational Voltage 240V a.c. 50Hz Resistive PHC 1, 2, 3, 4, 5, 6, 7, 8, 9, 10mA 240Va.c. Capacitive PHC Dimensions 1, 5, 10mA 240V a.c. 135mm(h) x 185mm(w) x 90mm(d) E15T 35

38 Area Classification Signs AREA CLASSIFICATIONS SIGNS SIGN/BPA AND SIGN/CPA The SIGN/BPA and SIGN/CPA Area Classification Signs provide indication as to the area classification, either Body or Cardiac protected, as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. Features Clearly identifiable in colour green Made from sturdy laminex Adhesive on each corner for easy installation Supplied with test and date stickers SIGN/BPA SIGN/CPA CAT NO. DESCRIPTION SPECIFICATIONS SIGN/BPA Body Area Sign Standard Colours Green SIGN/CPA Cardiac Area Sign Dimensions 150mm(h) x 200mm(w) SIGN/BPA AND SIGN/CPA 36

39 Electrical Safety - It's up to you VIDEO/1 This 24 minute video is aimed at providing health care workers with an overview of electrical safety, and promotes workplace safety. Features Introduction to electricity The effects of electricity on the human body Classifications of patient treatment areas Safe work practices Routine maintenance procedures CAT NO. VIDEO/1 DESCRIPTION Electrical Safety - It's up to you Electrical Design & Application - for patient treatment areas VIDEO/1 VIDEO/2 EDUCATIONAL VIDEOS VIDEO/2 The video is aimed at providing Hospital Engineering Departments, Engineering Consultants, and Electrical Contractors with an overview of planning, specifying, and installing the wiring systems to AS/NZS3003. Features Fundamentals of electricity and electric shock Classification of patient treatment areas Good design for patient treatment areas Selection of electrical fittings Installation of wiring and electrical fittings Testing and commissioning Routine maintenance procedures CAT NO. DESCRIPTION VIDEO/1 AND VIDEO/2 VIDEO/2 Electrical Design and Application 37

40 Why is there a need for special electrical installations in patient treatment areas? TECHNICAL INFORMATION WHY IS THERE A NEED? Modern medical procedures utilise and increasingly rely on, electrical and electronic equipment. This equipment ranges from lighting to patient monitors and electrosurgical equipment. The human body s main defence against the effects of electrical current passing through it are two-fold. Firstly, the resistance of the skin, which limits the amount of current that can pass. Secondly, the muscular contractions that accompany electric shock usually tend to disconnect the subject from the source of electrical energy. In medical procedures, both of these factors may be radically altered. Firstly, electrodes may enter the body or be attached to the skin, thus bypassing the skins resistance. Fluid may be taken from the body, treated and then returned (eg: kidney dialysis), providing a low resistance path for electrical current into the body. Secondly, the patient may be under anaesthetic. The source of the current (ie: an electrode) may be fastened to the patient and so not easily disconnected. Furthermore, where electrical conductors come in close contact with the heart (eg; in open heart surgery or pacemaker implantation), the imperceptible current that can flow between normally safe earthed conductors may result in micro shock, and possible death. There are three main results from current passing through the human body. Refer to graph on the following page. These are firstly, burning, particularly where the current enters and leaves the body. Secondly, muscular paralysis, which may temporarily halt breathing. Thirdly, electric shock may cause cardiac arrest; this ventricular fibrillation results in the pump chambers and valves of the heart going out of synchronisation, and blood ceases to be pumped around the body. The first two effects, whilst uncomfortable, seldom cause permanent damage. Ventricular fibrillation on the other hand, requires immediate reversal with the defibrillator before brain damage or death occurs. Electrical hazards are not only present for patients, but also for medical staff. The use of a multiplicity of equipment which individually presents no hazard may give rise to current paths within the patient circuit that cause a problem. Equipment that is designed to deliver current to patients (ie; diathermy electro-surgical units or defribillators) also have the potential, if damaged, mis-wired or incorrectly used, to produce an electrocution hazard to the patient of equipment operator. 38

41 TECHNICAL INFORMATION PHYSIOLOGICAL EFFECTS Zone 1 Usually no reaction effects. Zone 2 Usually no harmful physiological effects. Zone 3 Usually no organic damage to be expected. Likelihood of muscular contractions and difficulty in breathing. Reversible disturbances of formation and conduction of impulses in the heart, including atrial fibrillation and transient cardiac increasing with current magnitude and time. Zone 4 In addition to the effects to Zone 3, probability of ventricular fibrillation increasing up to about 5% (Curve C2), up to about 50% (Curve C3) and above 50% beyond Curve C3. Increasing with magnitude and time, pathophysiological effects such as cardiac arrest, breathing arrest and heavy burns may occur. WHY IS THERE A NEED? 39

42 Area Classification & Requirements TECHNICAL INFORMATION Medical treatment areas can be divided into the following three categories, as detailed in AS/NZS3003 Electrical Installations - Patient treatment areas of hospitals and medical and dental practices. UNPROTECTED AREA If procedures do not require the physical attachment of electro-medical equipment to the patient, electrical safety in such areas typically involves nothing more than normal domestic or industrial wiring practices. The area in this case is known as an Unprotected Area. BODY PROTECTED AREA Where electro-medical equipment is attached to external parts of the body so that contact resistance is reduced and ready disconnection is also not possible, Body Area Protection is required. Examples of areas and procedures that may require this type of protection are ECG, EMG, EEG, and Physiotherapy rooms, plus any room used for dialysis. AREA CLASSIFICATION & REQUIREMENTS A Body Protected Area requires installation of Residual Current Devices (RCDs) or Line Isolation and Overload Monitors (LIOMs) plus meeting the additional requirements detailed in AS/NZS3003. CARDIAC PROTECTED AREA Where electro-medical equipment is in close contact with the heart, Cardiac Area Protection is required. Examples of areas and procedures that may require this type of protection include CCU, ICU, and operating theatres where cardiac procedures are performed. A Cardiac Protected Area requires firstly RCD and/or LIOM protection as per Body Protected Areas, and secondly an Equipotential Earthing System plus meeting the additional requirements detailed in AS/NZS

43 RCD Functional Description An RCD provides macro electrocution protection by removing power when a fault current is detected. The RCD uses the magnetic field created around a current carrying conductor to detect the imbalance of current caused when a sufficiently low impedance path is provided to earth. This path may constitute a faulty piece of equipment, the patient, a member of the nursing staff, or a combination of these. The active and neutral conductors are passed through a toroid coil which is a coil containing many turns of wire around a doughnut shaped core. A changing magnetic field will cause a voltage to be induced into the coil. This voltage is detected and used to switch off the supply by opening the breaker contacts. During normal operation the currents flowing in the active and neutral conductors are equal and opposite, hence the voltage in the coil is zero. However, should current pass through a resistance to earth, the resulting imbalance of current flowing through the active and neutral conductors (the residual current) will, if it is of sufficient magnitude, cause the supply to be interrupted. TECHNICAL INFORMATION Any RCD in a Cardiac or Body Protected Area should trip off with a residual current of between five and ten milliamps (ma) and should interrupt the supply within forty milliseconds (ms) of the fault occurring. Please note that the RCD does not limit the magnitude of the fault current, it limits the duration that it flows. Schematic Diagram RCD FUNCTIONAL DESCRIPTION 41

44 Line Isolation & Overload Monitor Functional Description TECHNICAL INFORMATION The isolated supply comprises of a Line Isolation and Overload Monitor (LIOM) and isolation transformer, and is used to protect against macro electrocution. It is a continuous supply which differs from an RCD protected supply, which removes power when a fault is detected. An isolation transformer isolates the power from earth therefore a fault on both lines of the secondary transformer winding to earth needs to occur before a fault current flows. A fault on only one line and earth will not cause a fault current to flow. This current that does not flow is known as Prospective Hazard Current (PHC). A LIOM enables the integrity of an isolated power supply system to be continuously monitored. The LIOM is able to detect when one fault occurs therefore is able to warn of a potentially hazardous situation before any fault current actually flows. In order for the LIOM to monitor the isolation of any system with respect to earth, a small test signal must be injected between those same two points. If the test signal is to be applied continuously, it should be in a form which does not effect the integrity of the isolated system. For this reason, voltage sources cannot be used as they would solidly bind one part of the isolated system to earth. Current sources, on the other hand, exhibit a high impedance characteristic and if kept to a low amplitude, will not significantly effect the isolation of a system. The measurement of an impedance with a current source is relatively simple; inject a known current and measure the voltage drop across the test impedance. If, however, there is already a current flowing in the test impedance, the test current must be encoded in some manner so that the corresponding voltage drop may be determined. When measuring the impedance from one line to earth in this manner, the value obtained is equal to the parallel combination of all impedances between the isolated system and earth. The current that would flow in the event of a fault can be calculated by taking into account the voltages between each line and earth. LIOM FUNCTIONAL DESCRIPTION Schematic Diagram 42

45 Equipotential Earthing System Functional Description The Equipotential Earthing System is used to protect against micro electrocution. The EP Earthing system requires all earthed points within the cardiac protected area to be connected back to a common EP Junction via low resistance earth wiring (large cross section). The low resistance system reduces the potential difference between two earthed points in the area therefore reducing the risk of micro electrocution caused by the stray currents flowing the earthing system. Equipotential Earthing Connections in a typical cardiac protected electrical area TECHNICAL INFORMATION Note: Reference should be made to AS/NZS3003 for exact requirements of EP Earthing Systems. EP EARTHING FUNCTIONAL DESCRIPTION 43

46 Choosing between an RCD or LIOM TECHNICAL INFORMATION All socket outlets and directly wired equipment (eg; X-Ray machines) in Body and Cardiac Protected Areas must be protected by RCDs or an Isolated Supply and LIOM. The selection of whether to use an RCD or an Isolated Supply and LIOM depends on the type of procedures to be undertaken, taking into account current and future requirements. The main difference between the two systems of protection is in continuation of supply. If the interruption of the supply after the detection of a Line-to-Earth fault makes the RCD system unacceptable for medical reasons, the Isolated Supply and LIOM should be chosen. MAJOR POINTS OF COMPARISON If an evaluation determines that an Isolated Supply and LIOM are required for a particular procedure undertaken within one theatre, this requirement does not necessarily extend to all theatres in the suite or to all outlets in that particular theatre. Any one area may have some sockets protected by RCDs and some protected by Isolated Supplies and LIOMs. However, neither RCDs nor LIOMs in one Cardiac or Body Protected Area may supply sockets or equipment in another Cardiac or Body Protected Area, or in an unprotected area. No unprotected socket outlets are allowed within a Body or Cardiac Protected Area. RCD ISOLATED SUPPLY AND LIOM Ability to warn of a fault before fault current actually flows No Yes CHOOSING BETWEEN RCD OR LIOM Continuation of supply on Line-To-Earth fault No Yes Suitable for Body Protected Area Yes Yes Suitable use in a Cardiac Protected Area Yes Yes Macro Shock protection between live supply conductors No No Macro Shock protection from Line-To-Earth fault Yes Yes Indication of fault Yes Yes Socket outlets must be double pole switched No Yes Socket outlet to have red indication that power is switched on Yes Yes Socket outlets to have power available indicated by amber neon Yes No 44

47

48 Products of Clipsal Integrated Systems Pty Ltd ABN Head Office 12 Park Terrace, Bowden South Australia 5007 PO Box 103 Hindmarsh South Australia 5007 Telephone (08) International Facsimile (08) International Internet Offices in all States cis@clipsal.com.au NSW Sydney (02) Albury (02) VIC Melbourne (03) Country Areas QLD Brisbane (07) Townsville (07) SA Adelaide (08) WA Perth (08) TAS Launceston (03) NT Darwin (08) International Enquiries Head Office Export Department Telephone Facsimile export@clipsal.com.au New Zealand Clipsal Industries (NZ) Ltd (Auckland) Telephone Facsimile headoffice@clipsal.co.nz Customer Service Free Facsimile (0508) Auckland/Mobile Phone (09) Free Phone (0508) CLIPSAL Malaysia Clipsal Malaysia Sdn Bhd Lot 26, Jalan Pengapit 15/19 Shah Alam Industrial Estate Sham Alam Selangor Darul Ehsan West Malaysia, Malaysia Telephone Facsimile Singapore Clipsal Singapore Pte Ltd No. 5, Fourth Chin Bee Road Singapore Telephone Facsimile clipsal@cyberway.net.sg International Representatives China Clipsal China Ltd Telephone Greece Clipsal Hellas S.A. Telephone Hong Kong Clipsal Integrated Systems (HK) Limited Telephone South Africa Clipsal South Africa (Pty) Ltd Telephone Taiwan Clipsal (Taiwan) Co Ltd Telephone Thailand Clipsal Thailand Ltd Telephone United Kingdom Clipsal Ltd (UK) Telephone You can find this brochure and many others online in PDF format at: clipsal.com Follow the links off the home page or access the following page directly: clipsal.com/wat_lib_pdf.cfm clipsal.com/cis Clipsal Integrated Systems Pty Ltd reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. Copyright Clipsal Integrated Systems Pty Ltd Printed by Custom Press Pty Ltd (08) O/N May 03/03

medilec The Tools of a Specialist medical electrical equipment clipsal.com/cis

medilec The Tools of a Specialist medical electrical equipment clipsal.com/cis medilec medical electrical equipment The Tools of a Specialist clipsal.com/cis medilec medical electrical equipment page Contents 4 The Complete Package for Patient Treatment Areas 6 Bringing the World's

More information

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING MU TE ALARM MUT E D OVE R LOAD WAR NING E. S.P. E0 5 LI NE IS OLATION AND OVERLOAD MONITOR 9 6 5 ma 8 7 4 3 2 1 PO W E R PR OSPE CTIVE HAZ ARD CUR RENT LEVE L TE S T PHC WARNING Line Isolation & Overload

More information

Pure Glass. saturn.clipsal.com

Pure Glass. saturn.clipsal.com Pure Glass. saturn.clipsal.com Pure glass. Stylish in appearance and clever in design, Clipsal s new Saturn switch is beautifully crafted from pure glass, giving it a smooth reflective face and a style

More information

Clipsal Integrated Systems International Representatives China Head Office Greece Hong Kong South Africa Offices in all States Taiwan NSW VIC

Clipsal Integrated Systems International Representatives China Head Office Greece Hong Kong South Africa Offices in all States Taiwan NSW VIC f a c e t h e f u t u r e clipsalneo.com Everybody likes neo: stylish, modern and cleverly constructed, neo has an understated presence that people are drawn to. The attraction is a result of unwavering

More information

Energy cost saving made easy!

Energy cost saving made easy! Energy cost saving made easy! The Clipsal Energy Controller The most you ll ever save with the lights on. The Clipsal Energy Controller saves up to 30% of power used by fl uorescent lights, with minimal

More information

PERTH. Smart Living. C-Bus Control and Management System Case Study 13. clipsal.com

PERTH. Smart Living. C-Bus Control and Management System Case Study 13. clipsal.com Smart Living PERTH C-Bus Control and Management System Case Study 13 clipsal.com A Smart and Simple Automation Solution A collaborative effort between Perth based systems integrators, Surround Sounds,

More information

Mains Power Filter 970MF10 970MF20. Installation Instructions

Mains Power Filter 970MF10 970MF20. Installation Instructions Mains Power Filter Installation Instructions and Table of Contents 1.0 Warnings... 3 2.0 Introduction... 3 3.0 Quick Installation Overview... 3 4.0 Typical Installations... 3 5.0 Protection Concepts...

More information

Intercom Systems Video Intercoms

Intercom Systems Video Intercoms 8.0 International Offices CHINA Clipsal China Ltd Tel: +86 755 8237 5577 Fax: +86 755 8237 5576 sales@c-bus.com.cn GEORGIA Clipsal Contact Tel: +995 32 65 5599 Fax: +995 32 65 6699 clipsalcontact@gol.ge

More information

Universal Clamp Meter

Universal Clamp Meter Universal Clamp Meter Instruction Manual 489D F1365-04 10337881 489D UniversalClampMeter Instr.indd 1 5/11/2007 10:37:49 AM Table of Contents 1. Features...3 2. Specifications...4 3. Designations...5 4.

More information

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES ELECTRICAL SAFETY IN HEALTHCARE FACITILIES BY ENGR. S.M. NASEERUDDIN Dar Al-Majd Consulting Engineers Riyadh, Saudi Arabia ABSTRACT The increasing use of electrical diagnostic and treatment equipment in

More information

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components Iso-Gard Line Isolation Monitor (LIM) MLHG6-AU Setup Guide This document is intended as a guide for the basic physical setup of the Line Isolation Monitor (LIM). This document includes wiring diagrams

More information

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL Clipsal and C-Bus are registered trademarks of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008. All rights reserved.

More information

C-Bus Four Channel Analogue Output Unit Installation Instructions

C-Bus Four Channel Analogue Output Unit Installation Instructions C-Bus Four Channel Analogue Output Unit Installation Instructions 5504AMP Series REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3 4.0 Wiring

More information

DIGIHEAT IN LINE HEATERS

DIGIHEAT IN LINE HEATERS DIGIHEAT IN LINE HEATERS Installation and operation manual for Single & Three Phase Models Offices - Australia NSW - Sydney (Head Office) Tel: +61 2 9898 8600 QLD - Brisbane Tel: +61 7 3299 9900 VIC/TAS

More information

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE FINAL DISTRIBUTION PRODUCTS RANGE ISO 14001:2004 Certified ISO 9001:2008 Certified FUSES INDIA LTD Lawson Fuses India Ltd is a wholly owned subsidiary of Lawson Fuses Ltd,a long established UK company

More information

Operation and use. Functions and characteristics

Operation and use. Functions and characteristics Operation and use Function Vigirex relays measure the earth-leakage current in an electrical installation via their associated toroids. Vigirex relays may be used for: b residual-current protection (RH10,

More information

C-Bus Four Channel General Input Unit Installation Instructions

C-Bus Four Channel General Input Unit Installation Instructions C-Bus Four Channel General Input Unit Installation Instructions 5504GI Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities...

More information

Flexibility from floor to ceiling

Flexibility from floor to ceiling Product Overview Catalogue Flexibility from floor to ceiling Overview Established in 1920, Clipsal by Schneider Electric is Australia s number one brand of electrical products, accessories and solutions

More information

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions C-Bus Pascal Automation Controller 5500PACA Installation Instructions Contents 1.0 Description...3 2.0 Important Notes...3 3.0 Capabilities...3 4.0 Wiring Instructions...4 4.1 Battery Back up...5 4.2 Connecting

More information

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Copyright Clipsal Australia Pty Ltd, 2008. All rights reserved. This material is copyright

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions 5102BCLEDL REGISTERED PATENT Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities...

More information

Consumer Switchboards 4CS & 4FCS. Installation Instructions

Consumer Switchboards 4CS & 4FCS. Installation Instructions Consumer Switchboards 4CS & 4FCS Installation Instructions Table of Contents 1.0 Dimensions...3 1.1 4CS Series Surface Mounting Consumer Switchboard Dimensions in mm...3 1.2 4FCS Series Flush Mounting

More information

NZECP 12:1993 ISSN COVER PAGE

NZECP 12:1993 ISSN COVER PAGE NZECP 12:1993 ISSN 0114-0663 COVER PAGE NZECP 12:1993 NEW ZEALAND ELECTRICAL CODE OF PRACTICE for ELECTRICAL INSTALLATIONS THE SAFE USE OF ELECTRICITY IN MEDICAL LOCATIONS AND ASSOCIATED AREAS Issued by

More information

ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011

ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011 Candidate Code No. ESAI 27 For Board Use Only Result Date Result Date Int ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011 QUESTION AND ANSWER BOOKLET Time Allowed: 3 Hours INSTRUCTIONS

More information

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW Installation Instructions REGISTERED DESIGN Copyright Notice The concepts, products and designs described in this document are the subject of

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

Circuit Breaker with Residual Current Protection (CBR)

Circuit Breaker with Residual Current Protection (CBR) Circuit Breaker with Residual Current Protection (CBR) 3A-30mA-100mA-300mA-500mA- Safety and protection are the prime purposes of Terasaki products. You care about safety and protection. The users of products

More information

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT C-Bus Black & White MK II Desktop Touchscreen 5000CTD2 Series REGISTERED DESIGN REGISTERED PATENT Clipsal is a registered trademark of Clipsal Australia Pty Ltd ABN 27 007 873 529. C-Bus is a registered

More information

C-Bus Neo Range Installation Instructions. 5050NL Series

C-Bus Neo Range Installation Instructions. 5050NL Series C-Bus Neo Range Installation Instructions 5050NL Series Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Installation Procedure... 4 3.1 Installation Location... 4 3.2 Installing

More information

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide C-Bus Black & White MK II Touch Screen 5000CT2 Series Clipsal is a registered trademark of Clipsal Australia Pty Ltd ABN 27 007 873 529. Neo is a registered Trademark of Clipsal Australia Pty Ltd. Copyright

More information

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation Documentation GEM-C Wireless User & Installation Manual Revision October 2014 Apollo Solar Electric Limited Contents GEM-C Wireless User Manual 3 Important Safety Information 3 Introduction 4 The GEM-C

More information

Residual Current Devices

Residual Current Devices Residual devices F200 Series UL 1053 Residual devices F200 Series Residual Current Devices Description The F200 Series residual devices offer a wide range of product for all of your fault protection needs.

More information

DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home.

DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home. DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home. Don t become a statistic Australia has one of the world s safest environments, yet electricity and our surroundings still

More information

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management Reyrolle Protection Devices 7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management 7XG3120 - Arc Fault Monitor Relay The over-current caused by an arc is, due to its resistance, lower than the over-current

More information

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671 Contents 1 The IET Regulations, BS 7671, and this Guide 1 1.1 The need for this Electrician s Guide 1 1.2 The IET Regulations BS 7671 2 1.2.1 International basis 2 1.2.2 The Seventeenth Edition 3 1.2.3

More information

Push Button Electronic Timer. 31VETR Series. Installation Instructions

Push Button Electronic Timer. 31VETR Series. Installation Instructions Push Button Electronic Timer Series Installation Instructions Contents 1.0 Product Range... 3 2.0 Description... 3 3.0 Features... 3 4.0 Important Warnings... 3 5.0 Timer Control... 4 5.1 Push Button Control...

More information

C-Bus Reflection Range Installation Instructions

C-Bus Reflection Range Installation Instructions C-Bus Reflection Range Installation Instructions R5060 Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Parts Supplied...3 4.0

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

Electrical Management

Electrical Management 5 WHS PROCEDURE P23-01 Page 1 of 9 Issue: 2 1. Intent The Salvation Army Australia Eastern Territory (TSA-AUE) is committed to the provision of a safe, healthy and injury free environment within the mission

More information

AS/NZS 3190:2011 AS/NZS

AS/NZS 3190:2011 AS/NZS AS/NZS 3190:2016 Australian/New Zealand Standard Approval and test specification Residual current devices (currentoperated earth-leakage devices) Superseding AS/NZS 3190:2011 AS/NZS 3190:2016 AS/NZS 3190:2016

More information

IT system floor-standing distribution

IT system floor-standing distribution IT system floor-standing distribution cabinet series -IPS-F/EDS for supplying power to medical locations in accordance with IEC 60364-7-710 and featuring a built-in insulation fault location system IT

More information

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must

More information

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions Push Button Electronic Timer 31VETR3 Series Installation Instructions Contents 1.0 Product Range... 3 2.0 Description... 3 3.0 Features... 3 4.0 Important Warning... 3 5.0 Timer Control... 4 5.1 Push Button

More information

LC2200 Level Controller Installation and Maintenance Instructions

LC2200 Level Controller Installation and Maintenance Instructions 4025250/9 IM-P402-77 AB Issue 9 LC2200 Level Controller Installation and Maintenance Instructions LC2200 ALARM TEST >50% >100%

More information

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT Trailing Edge Dimmer 32E450T Series Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Product Range...3 2.0 Description...3 3.0 Features...3 4.0 Load Compatibility...4

More information

ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET Candidate Code No. EAS 1081 For Board Use Only Result Date Int Result Date Int ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time

More information

ES8. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

ES8. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int ES8 Candidate Code No. For Board Use Only Result Date Int Result Date Int ELECTRICAL WORKERS REGISTRATION BOARD ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 9 September 2006 QUESTION AND ANSWER BOOKLET

More information

The CAB & DAB Air Curtains

The CAB & DAB Air Curtains The CAB & DAB Air Curtains Frequently Asked Questions General Positioning Page 2 Electrical & Connection Page 4 Electric Heated Page 5 Electronic door triggered shutdown feature (Electric) Page 5 Electronic

More information

Airflow. Add a little Sunshine to your bathroom

Airflow. Add a little Sunshine to your bathroom Airflow Add a little Sunshine to your bathroom clipsal.com Airflow Sunshine 2 x 275W heat-lamp model 6600A The 6600A is suitable for small bathrooms and en suites with ceilings of average height 2.7 metres

More information

Pedestal Fan. 12 months. 3 Speed, 40cm R2000B

Pedestal Fan. 12 months. 3 Speed, 40cm R2000B 3 Speed, 40cm R2000B 12 months Important Safeguards When using electrical appliances, in order to reduce the risk of fire, electric shock, and/or injury, these basic safety precautions should always be

More information

Guide to: 17 th Edition Consumer Units

Guide to: 17 th Edition Consumer Units Guide to: 17 th Edition Consumer Units Introduction For well over one hundred years the Wiring Regulations have provided the rules which must be followed to make sure that electrical installations are

More information

Requirements for Electrical Installations

Requirements for Electrical Installations BRITISH STANDARD BS 7671:2008 + Amendment 1:2011 (Corrigendum June 2013) Requirements for Electrical Installations IET Wiring Regulations Seventeenth Edition ISBN-13: 978-1-84919-730-4 BS 7671 Requirements

More information

754 Series. See Motion Sensors. in a new light. Sleek new styling and more features than ever before.

754 Series. See Motion Sensors. in a new light. Sleek new styling and more features than ever before. See Motion Sensors in a new light. Sleek new styling and more features than ever before. Clipsal s new Outdoor Infrascan range won t leave you in the dark. The new 754 Series Outdoor Infrascan Range is

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

PORTAPAC / DELTA HOT. Installation and Operation Manual.   ! WARNING PORTAPAC / DELTA HOT Installation and Operation Manual! WARNING This equipment must be installed and serviced by a qualified technician. Improper installation can create electrical hazards which could

More information

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features Product Guide MWS3A-PRM Ceiling microwave presence/absence detector Overview The MWS3A-PRM microwave presence detector provides automatic control of lighting loads with optional manual control. The MWS3A-PRM

More information

StarServe IR/RF Controller Installation Instructions. 2031RFT Series

StarServe IR/RF Controller Installation Instructions. 2031RFT Series StarServe IR/RF Controller Installation Instructions 2031RFT Series Table of Contents Section Page 1.0 Product Range...3 2.0 Description...3 3.0 Features...3 4.0 Installation Instructions...4 5.0 Important

More information

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw Underceiling/Console Split System Air Conditioners Technical Data ISU Series Featuring SAT- Controller & Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 13. kw 15 kw NOVEMBER 0 ISU SERIES

More information

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V Universal Dimmer Integrally Switched Rotary Controlled 31E2RUD Series ROTARY CONTROL INTEGRALLY SWITCHED 240V 450W Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Product

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

Welcome to Hager Presentation

Welcome to Hager Presentation Welcome to Hager Presentation Topics Intro to Hager Group Circuit Protection Enclosures Q&A IIEE Manila 4 th August 17 13.03.2009 2 Company presentation Who we are Hager Group is a leading provider of

More information

The complete residential solution

The complete residential solution The complete residential solution Circuit Protection Resi MAX Clipsal.com/ResidentialProtection Contents What s new in final distribution residential...3 Resi MAX gives you the entire solution...4 Essential

More information

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET EST 2066 Candidate Code No. For Board Use Only Result Date Int Result Date Int ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Two Hours INSTRUCTIONS

More information

Evaporative Cooler. 8 Litre MEC1R

Evaporative Cooler. 8 Litre MEC1R Evaporative Cooler 8 Litre MEC1R Important Safeguards When using electrical appliances, in order to reduce the risk of fire, electric shock and/or injury, these basic safety precautions should always be

More information

by Clipsal Australia Medilec Hospital Solutions World Leading Specialist Medical Electrical Accessories

by Clipsal Australia Medilec Hospital Solutions World Leading Specialist Medical Electrical Accessories by Clipsal Australia Medilec Hospital Solutions World Leading Specialist Medical Electrical Accessories Keep the bugs at bay with Germ-shield. H O S P ITA L S AGE D C A RE D E NTAL Revolutionary Anti Microbial

More information

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms Clipsal FireTek Smoke Alarms Photoelectric Smoke Alarms clipsal.com/smokealarms Iconic and Clipsal Iconic are trademarks of Schneider Electric (Australia) PTY Limited. 2 clipsal.com/smokealarms Your customers

More information

Orange Solar Pump HD50

Orange Solar Pump HD50 Orange Solar Pump HD5 36 volt DC brushless step motor Loss of prime protection - Automatic tank filling How the pump works The HD5 centrifugal solar pump is made of stainless steel with a plastic impeller.

More information

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT TrailingE dge Dimmer 32E450T Series Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Product Range...3 2.0 Description...3 3.0 Features...3 4.0 Load Compatibility...4

More information

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site INDOOR INFRASCAN Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL Please leave these instructions at the installation site Contents Section...Page 1 Product Range...3 2 Description...3 3

More information

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Light Level Detector, Surface Mount 5754PE. Installation Instructions Light Level Detector, Surface Mount 5754PE Contents 1.0 Introduction 3 2.0 Safety and Product Handling 3 3.0 Installation 4 3.1 Removing the Top Cover 4 3.2 Installing the Mounting Hardware 4 3.3 Mounting

More information

POOL & SPA SUCTION FITTINGS

POOL & SPA SUCTION FITTINGS POOL & SPA SUCTION FITTINGS Installation and Operation Manual! WARNING Read and follow all instructions in this Instruction manual and on the equipment. Failure to follow instructions may cause severe

More information

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate. This safety certificate is an important and valuable document which should be retained for future reference DETAILS OF THE CLIENT Client / DETAILS OF THE INSTALLATION Extent of the installation covered

More information

Universal Dimmer E450UD Series. Installation Instructions

Universal Dimmer E450UD Series. Installation Instructions Universal Dimmer E450UD Series Installation Instructions Table of Contents... 3... 3... 3... 4... 4... 5... 5 6.1 Wiring Details... 5 6.2 Soft-Start Feature... 5 6.3 Minimum Brightness Settings... 5 6.4

More information

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual MANUAL We manage heat Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 http://www.networketi.com/

More information

ESP TECHNOLOGIES LIMITED

ESP TECHNOLOGIES LIMITED Alarm Technology ESPAN-01 Series Annunciator System Combination type User Manual (Rev. 1) ESP TECHNOLOGIES LIMITED www.esptechno.com Content Page Introduction 2 General Description 2 Overview - Annunciator

More information

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013

More information

LABORATORY ILLUMINATED FLOTATION BATH

LABORATORY ILLUMINATED FLOTATION BATH LABORATORY ILLUMINATED FLOTATION BATH MODELS INCLUDE: TFB-1 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 6862 Wetherill Park DC NSW 1851

More information

Instruction Manual WARNINGS

Instruction Manual WARNINGS Instruction Manual LARGE COMMERCIAL RECESSED AIR CURTAIN HSACR9000, 12000 & 18000 ELECTRICALLY HEATED RECESSED AIR CURTAINS WITH ENERGY SAVING CONTROLS INSTALLATION AND OPERATING MANUAL INDEX Section General

More information

Ceiling Mounted Ducted Exhaust Fan Kit

Ceiling Mounted Ducted Exhaust Fan Kit Ceiling Mounted Ducted Exhaust Fan Kit Installation Instructions CEF40WK CONTINUOUS OPERATION RESIDENTIAL APPLICATIONS Table of Contents Included With This Fan...3 Not Included With This Fan...3 Before

More information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required

More information

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V ROTARY CONTROL INTEGRALLY SWITCHED 240V Universal Dimmer Integrally Switched Rotary Controlled 31E2RUD Series Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Product

More information

Wireless Electricity Monitor. User Manual REGISTERED PATENT

Wireless Electricity Monitor. User Manual REGISTERED PATENT Wireless Electricity Monitor User Manual REGISTERED PATENT 1.0 Introduction Thank you for selecting the Clipsal Centameter Wireless Electricity Monitor. Keeping an eye on your electrical usage has never

More information

Systems of inspecting the existing building and the procedures of auditing engineering plans. M. Mostafa

Systems of inspecting the existing building and the procedures of auditing engineering plans. M. Mostafa Systems of inspecting the existing building and the procedures of auditing engineering plans M. Mostafa 2 Agenda 1. Introduction 2. Why inspection? 3. Initial Verification 4. Periodic verification 5. Reference

More information

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw Ducted Three Phase Packaged Air Conditioners Technical Data 96 RKTBG-P Plug Fan with High Efficiency EC Motor and High External Static Economiser Option TZT Controller & Digital Scroll Compressor for close

More information

SMARTWALK DEMENTIA WANDERING SYSTEM

SMARTWALK DEMENTIA WANDERING SYSTEM A division of NESS CORPORATION PTY LTD SMARTWALK DEMENTIA WANDERING SYSTEM SWD Door Responder SWD Resonator SWD-PET (Sold Separately) SWD-PET-BAND (Sold Separately) INSTALLATION MANUAL 1. CONTENTS 1. CONTENTS...1

More information

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection) RESIDUAL CURRENT DEVICE (RCD) - Contents 1. Introduction 2. General 3. RCCB (residual current operated circuit-breaker without integral overcurrent 4. RCBO (residual current operated circuit-breaker with

More information

Installation plan Heat pump dryer PT 8203 SL WP

Installation plan Heat pump dryer PT 8203 SL WP Installation plan Heat pump dryer PT 8203 SL WP To avoid the risk of accidents or damage to the machine, it is essential to read these instructions before it is installed and used for the first time. en

More information

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX MANUAL OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX 1) Technical Specifications: (100VA, 200VA, 300VA) 2) Introduction 3) Construction 4) Operation and maintenance a) Operating Procedure b)

More information

COLLECTION. Stands out from the crowd, blends in with the home

COLLECTION. Stands out from the crowd, blends in with the home COLLECTION Stands out from the crowd, blends in with the home Let the Sleek Look of Clipsal Saturn Define Your Sense of Style Clipsal Saturn is a premium range of architecturally designed electrical accessories.

More information

Electrical Safety Tips. Help us keep you safe.

Electrical Safety Tips. Help us keep you safe. Electrical Safety Tips. Help us keep you safe. To help you stay safe when using electricity, Evoenergy has compiled these electrical safety tips. For natural gas safety tips please see Evoenergy s natural

More information

ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET Candidate Code No. EIN 11 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER THEORY EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS

More information

ultimate climate control and advanced energy efficiency THE ESP SERIES

ultimate climate control and advanced energy efficiency THE ESP SERIES ultimate climate control and advanced energy efficiency THE ESP SERIES art perform rm ener nergy smart energy performance smar t performance gy smar art performance rmance designed & built in australia

More information

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933 Two-hand Safety Control Module FF-SR Series FEATURES Complies with the Machinery Directive 98/37/EC and UL 508 Type III C per EN 574, Category 4 per EN 954-1 Inputs for two dual-contact pushbuttons 0,5

More information

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT QUICKSMART Universal Exit Light EXITSM Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Welcome...3 2.0 Safety Warnings...3 3.0 Installation Instructions... 4-5 4.0 Maintaining

More information

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1 Instruction Manual M6627 / Version 7.4 Slide Drying Bench MH6616 MH6616X1 Please take your time to read this Instruction Manual in order to understand the safe and correct use of your new Electrothermal

More information

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual VoCALL - CFVCC5 Compact 5 Line Exchange Unit Installation & Commissioning Manual Introduction A VoCALL Emergency Voice Communications System (EVCS) is a fixed, secure, bi-directional, full duplex voice

More information

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site. Indoor Infrascan Passive Infrared Motion Sensor 751 Series Installation Instructions Please leave these instructions at the installation site. Table of Contents 1.0 Product Range...3 2.0 Description...3

More information

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional

More information

LC3000 Level Controller Installation and Maintenance Instructions

LC3000 Level Controller Installation and Maintenance Instructions 4025550/12 IM-P402-36 AB Issue 12 LC3000 Level Controller Installation and Maintenance Instructions 1. General safety information LC3000 NORM ALARM TEST 2. General product information 3. Installation 4.

More information