Electrical Installations

Size: px
Start display at page:

Download "Electrical Installations"

Transcription

1 Electrical Plants

2 Each kit is complete with cables, clips, screws, joint boxes, plugs and necessary electrical accessories ready to install. Installation instruction and circuit diagrams are prepared in pedagogical sequence thus ensuring easy installation and correct function. These training kits are designed to be installed on assembly boards which are placed in special frames. The boards can be removed from the frames and stored in a rack built for this purpose. TELAIO Assembly Frame Mobile work island on wheels for four students with four independent spaces. An advantage of this solution is that students can work by switching quickly from the front to the back of each panel simply by rotating it. Mobility/stability: The four wide-diameter wheels ensure that the island is easy to move around, yet it remains extremely stable when the four brakes are applied and locked in place. Features of each space Panel with melamine agglomerate on the front and back (12mm), 1700 x 800mm of usable space. Rotation of panel around its central vertical axis Lock for locking the anti-rotation system Independent console Tool holder Dimensions of island Panels with melamine agglomerate on the front and back (12mm), Dim: 1700 x 800mm Dim x 1120mm Height: 1994mm (with power supply) Dim: 940 x 940mm. Height: 1994mm (without power supply) TELAIO Single-Phase Vertical Console General protection Protection by magneto-thermal circuit breaker (30mA residual current circuit breaker available as an option) 1. Emergency stop. This push button cuts off the power in the case of an emergency. Key-resettable (positive safety) VAC insulated supply. Output via 2 safety terminals. Primary winding of transformer protected by auto-protection and secondary wiring by circuit breaker and switch. 3. Start/Stop. - A lamp indicating that the power is on. - Start/stop operated using a double push-button VAC mains distribution. Two power sockets 230V with lamp. 2

3 IMP-01 PVC Conduit Installation Kit Installation practice using PVC conduit in concealed conditions, complimented with different wiring circuits including intermediate switching and socket circuits. The kit consists of Cable 3x1.5 mm sq Conduit cable 1 x 1.5 mm sq, white Conduit cable 1 x 1.5 mm sq, black Conduit cable 1 x 1.5 mm sq, blue Conduit cable 1 x 1.5 mm sq, yellow/green Junction box Terminal mounting box Blanking plates, diameter 100 mm Cable connectors PVC tubing flexible, approx. 15 mm diameter Earth plug Switch, one way Switch, one way, double Switch, two way (stair case) Switch, intermediate Wall socket, one way, with earth Wood screws (4.15 x 19) Wood screws (for mounting boxes) Lamp holder, complete Bulbs Plastic bin Hole cutter T 70 (diameter 74 mm) Hole cutter T 80 (diameter 84 mm) Set of drills for wood Draw spring 10 m 100 m 100 m 100 m 100 m 4 pcs 9 pcs 4 pcs 20 m 3 pcs 30 pcs 3 pcs 5 pcs IMP-02 Installation Kit for Surface Wiring To be used for developing skills in clipping, bending and setting of surface mounted wires and cables, making circuit connections from a fuse experiment panel to single and three phase outlets, circuit breakers, controllers, etc. The kit consists of Distribution panel MCB 10 A 1-pole Main switch Motor starter/circuit breaker with contactor and overload relay Push button control box Safety switch 3-phase outlets Direct-on-line starter (manual) Cable 5 x 1.5 mm sq. Clips TC Wood screws (4 x 16) Wood screws (4 x 30) Plastic bin s 9 pcs 3 pcs 100 m 200 pcs 3

4 IMP-03 Three-phase Motor Wiring Kit To be used for practical exercise in realistic full size wiring of industrial type of motor controls in accordance with wiring standards. A three-phase motor is connected to the mains supply via a starter, fuseboard, earth leakage circuit breaker and kwh meter. PVC surface cable is used throughout except for the connection between the motor and terminal box where flexible conduit PVC single cable is used. Direct on line, manual, star delta and automatic star delta staring can be connected into the circuit. Isolated earthing is necessary on the motor circuit for correct operation of the ELCB. The kit consists of 3-phase AC motor Distribution panel complete with three MCB 10 A 1-pole and main switch kwh-meter, 3-phase, Earth leakage protection device Motor starter/circuit breaker with contactor and overload relay Direct-on-line starter (manual) Manual Y/D starter Automatic Y/D starter Cable 5 x 1.5 mm sq Clips TC Wood screws Plastic bin 100 m 200 pcs IMP-04 Installation Kit for Lighting Wiring To be used for the student to practice in wiring of lighting control circuits with fluorescent and incandescent lamps. Two lighting control circuits are incorporated in this module. In the first circuit, a fluorescent lamp and an incandescent lamp are controlled by an automatic system using a photo-cell operated relay. In the second circuit, a fluorescent lamp and an incandescent lamp are controlled by a manual pushbutton which operates a timing circuit. The kit consists of Pushbutton box with contactor Distribution panel MCB, 10 A, 1-pole Photo cell operated relay Staircase relay Switch, 2-pole Cable 3 x 1.5 mm sq. Cable 4 x 1.5 mm sq. Main cable Junction box Fluorescent lamp holder with choke and starter Fluorescent lamps Lamp holder, complete Bulb Clips TC 7-10 Wood screws (4 x 16) Wood screws (4 x 30) Plastic bin 10 pcs 100 m 25 m 3 pcs 500 pcs 4

5 IMP-05 Residential Wiring Trainer Kit Residential Wiring Trainer (Kit) for instruction in principles and schematic diagrams of electric wiring in apartments. The trainer consists of complete modules, representing a typical floor plan of an apartment. The trainer utilises, as much as technically possible, full size electrical components as switches, circuit breakers, receptacles, light fixtures and lamps. Supply voltage: 24 V AC, 3-phase system from an overload protected power supply, simulating a V 3-phase system. The trainer is equipped with an energy meter. Complete with: Set of components to meet residential wiring curriculum requirements. Wire package set Hand tool set necessary for wiring. Student Work Book. Laboratory manual describing residential wiring fundamentals such as: wiring material components and equipment conductors and overload protection wiring circuits, designing and wiring of a complete electrical system, installation of cables, raceways and trouble-shooting. The kit consists of Cable 5 x 1.5 Cable 1.5, black Cable 1.5, blue Cable 1.5, brown Cable 1.5, yellow/green Junction box Terminal mounting box Cable connectors PVC tubing flexible Switch, one way, double Switch, two way Wall socket, two way, no earth Clips, JR 16 Wood screws (4 x 10) MBC 10 A, 1-pole Wall socket Bulbs, 24 V, 60 W Lamp holder 3-ph transformer Main switch kwh-meter 5 m 200 m 200 m 200 m 200 m 8 pcs 30 m 6 pcs 6 pcs 2 pc 6 pcs 6 pcs Hand tool set consists of Screwdriver (-) 3.5 * 75mm Screwdriver (-) 4.0 * 100mm Screwdriver (-) 5.5 * 125mm Screwdriver (-) 6.5 * 150mm Screwdriver (+) PH0 * 60mm Screwdriver (+) PH1 * 75mm Screwdriver (+) PH2 * 125mm Pliers Long nose pliers 160mm Pliers Diagonal pliers 160 mm Pliers Round nose pliers 160 mm Pliers Combination pliers 180mm Kit tool electrical work, this screwdriver and pliers set is designed with insulated handles to protect against shock up to 1000 volts 5

6 IMP-10 Automatic Fire Alarm Kit for installation practice with self-training instructions. Supplied in a strong plastic bin. The kit includes Master Station Heat detector Smoke detector Alarm pushbutton Bell Plug, cable and screws, etc. Handbook IMP-11 Office Signaling Installation Kit for installation practice with self-teaching instructions. Supplied in strong plastic bin. The kit includes Transformer Master station Indicator panel Indicating contact Cable, clips, pins, screws Handbook IMP-12 Visual Nurse System Kit for installation practice with self-teaching instructions. Supplied in strong plastic bin. Installation Kits for Alarm, Control, and Safety Systems Vocational and Technical Schools which cater for Alarm-, Control- and Safety systems training, low voltage training, must have practical assignments to complete the course of study. The following list of training kits which are designed to meet with syllabus requirements and to eliminate wastage of planning and issue time. Each kit is complete with cables, screws and accessories required for the exercise. These are stored in a plastic bin to simplify storage and issue. The components are of standard type as used for normal installations. The manual or instruction handbook included, is prepared for the student to proceed with a project with a minimum of supervision. On completion and check of the installation the system can be energised and made operational. The kits are mostly suited for mounting on wooden panels e. g. chipboards OF.0320F.IE on the frame OF.030F.IE or similar training surfaces. The kit includes: Transformer Central unit Calling units Resetting unit Presence indicating unit Presence indicating unit with sound alarm Cable, clips, screws, LEDs Handbook 6

7 OF.0340.IE Sheet-metal cabinet It can contain 6 panels for industrial or domestic exercises, also with the components mounted. In this way the student can go on with the exercise in another lesson. It has two wings with lock-key and the distance between the panels is 120 mm. Dimensions: 1000 x 900 x 900mm. Cabinet close Cabinet open OF.030F.IE Frame The frame has a firm construction, made of steel. This frame has the possibility to have a power supply unit placed horizontally under the frames. The profile dimension of the steel bars is 25 x 50 mm. Dimensions 800 x 800 x 400 mm. OF.0320.IE Perforated Metal Board Perforated sheet-steel panel. Dimensions: 800 x 800 mm. Unthreadable and turning. OF.0310.IE Wooden Board Wooden made, 20mm thickness. Dimensions 800 x 800 mm. Unthreadable and turning. 7

8 OF.033P.IE Power Supply Panel The power supply panel is manufactured in sheet metal. It is constructed to be placed horizontally under the frame. The panel comprises: Main switch Indicator lamp MCB, single-phase MCB, three-phase Earth fault circuit breaker Three-phase socket 400 V / 230 V 2-pole earthed wall sockets 230 V Emergency stop Power supply ±5VDC, ±12VDC, ±15VDC and ±24VDC Three-phase terminals L1, L2, L3, N, PE Switch and indicator lamp 6 pcs OF.034P.IE Power Supply Panel The power supply panel is manufactured in sheet metal. It is constructed so it can be placed vertically besides the frame or between two frames. The panel comprises Main switch Indicator lamp MCB, single-phase MCB, three-phase Earth fault circuit breaker Emergency stop Three-phase terminals L1, L2, L3, N, PE Connection box Switch for terminals and connection box Three-phase socket 400 / 230 V 2-pole, 2-way earthed socket 230 V Power supply 0 - ± - 12 V DC 8

9 IMP-40 Electrical Student Tool Kit Contents Tool box Screwdriver set Flat nose pliers Diag. cutting nippers Wire stripper Hammer, cross pein Hacksaw frame Water pump pliers Woodworkers knife Measuring tape Adjustable wrench Voltage tester Brad awl Round-nose plier Contents Storage cabinet Screwdriver set Plumb-Bob Plumb-Line Level Carpenters hammer Drill brace Center bit, 10 mm Center bit, 16 mm Center bit, 22 mm Center bit, 25 mm Portable electric drill (Percussion) Masonry drills set 5-10 mm Drill set MAXI-Box Hacksaw blade RS 1218 Hacksaw blade RS 1224 Hacksaw blade RS 1232 Set of ring spans mm Open ended spanner Soldering pen, earthed Soldering pen W61 Soldering pen W101 Hand file Square file Three sq. file Half-round file File handle Tool kit 135 PC Water pump pliers 12 rolls 2 sets 2 sets 1 set 1 set 60 pcs 1 set 3 pcs IMP-41 Electrical Workshop Tools 9

10 IMP-13 L-A Electrical Systems Of Anti Theft Alarm This system has been designed so that students can assemble, analyze and test a wide range of more and more complex electric circuits; it consists of interchangeable modules; thus merely connecting these modules with each other via flexible leads supplied with the equipment enables to assemble various circuits. Modules are made of insulating material and they represent the support of the necessary devices for implementing the experimental programme, besides offering the graphic representation and standardized electric symbol of the component; connections are made easier by standardized educational terminals (Ø 4 mm) with high protection degree against accidental contacts. Testing modules for electrical systems of anti theft alarm This set of modules for alarm systems has been designed specifically to assemble, analyze and test electric systems of detection and signaling in the field of anti theft system for civil and service sectors. Modules can be inserted in bench to implement the training programme. As an alternative, testing frame can be used and the equipment can be powered by power supply unit (both these units are supplied separately, on demand). Training program: one-zone burglar alarm system, with electronic control unit, microwave presence detector and additional siren two-zone burglar alarm system, with electronic control unit, passive infrared presence detector, microcontacts, additional siren and self-powered outdoor siren two-zone burglar alarm system, with electronic control unit, passive infrared presence detector, microwave presence detector, microcontacts, electronic key for remote control of control unit, additional siren and self-powered outdoor siren Technical specifications: The set of modules for implementing alarm systems includes: 1 electronic control unit with 4 alarm lines, self-protected with 24h anti-sabotage line and self-powered by buffer battery. Power supply: 230 Vac. Output: 12 VDC 1 volumetric sensor of double technology (microwaves and IR); microwaves with operating range up to 10 m. 1 passive infrared volumetric sensor with operating range up to 10 m. Power supply: 12 VDC 1 magnetic detector with NC contact 1 inertial sensor with NC contact 1 sensor of vibration and glass breaking with NC contact 1 indoor alarm device with two-tome electronic siren. 1 outdoor electronic siren with flashing light, self-protected and self-powered with battery of 12 VDC 1 remote keyboard for enabling, disabling, choking and for total control of electronic control unit (remote programming) 1 remote electronic key for enabling, disabling, chocking the control unit Supplied accessories: set of 30 cables with safety plugs (Ø 4 mm) 10

11 IMP-13 A Lighting Installations This system has been designed so that students can assemble, analyze and test a wide range of more and more complex electric circuits; it consists of interchangeable modules; thus merely connecting these modules with each other via flexible leads supplied with the equipment enables to assemble various circuits. Modules are made of insulating material and they represent the support of the necessary devices for implementing the experimental programme, besides offering the graphic representation and standardized electric symbol of the used component; connections are made easier by standardized educational terminals (Ø 4 mm) with high protection degree against accidental contacts. Testin g modules for lighting installations The set of modules for lighting installations has been designed specifically to assemble, analyze and test lighting installations of civil and service sectors. Modules can be inserted in bench to implement the training programme. As an alternative, testing frame can be used and the equipment can be powered by power supply unit (both these units are supplied separately, on demand). Training program: lamp controlled from a point groups of lamps controlled by two switches groups of lamps controlled by a changeover switch group of lamps controlled from two points + 1 socket group of lamps controlled from 3 points + 3 sockets group of lamps controlled from 3 points with relay groups of lamps controlled from 3 points groups of lamps controlled from 3 points by switch relay control of fluorescent lamp lighting system of a hotel bedroom lighting system of archives from 3 points system for switching staircase light on with a certain timedelay lighting system for a flat lighting from 2 points by touch sensitive electronic switches lighting by dimmer switch Technical specifications: The set of modules for assembling the lighting installations includes: 2 switches for civil uses 1 changeover switch for civil uses 2 two-way switches for civil uses 2 inverters for civil uses 2 pushbuttons for civil uses 1 switch relay (coil of 230 V) 2 changeover switch relay (coil of 24 V) 2 lamp-sockets for schematic diagrams with lamps 1 single-phase socket 230 V 10 A 1 single-phase socket 230 V 16 A 5 board fuse-holders with breakable fuses of 4/6 A 1 reactor for fluorescent lamp 1 capacitor and starter for fluorescent lamp 1 fluorescent lamp with pins 1 transformer / V Hz 72 VA 1 timing relay (powered by 230 VAC) for staircase lighting 1 LED button for stairwell lighting with neon glow lamp of 230 V 1 electronic dimmer switch, 500 W 230 V 1 touch sensitive LED button, 500 W 230 V Supplied accessories: set of 50 cables with safety plugs (Ø 4 mm) 11

12 IMP-13 L-B Fire Fighting And Technical Alarm Systems This system has been designed so that students can assemble, analyze and test a wide range of more and more complex electric circuits; it consists of interchangeable modules; thus merely connecting these modules with each other via flexible leads supplied with the equipment enables to assemble various circuits. Modules are made of insulating material and they represent the support of the necessary devices for implementing the experimental programme, besides offering the graphic representation and standardized electric symbol of the component; connections are made easier by standardized educational terminals (Ø 4 mm) with high protection degree against accidental contacts. Testing modules for fire fighting and technical alarm systems This set of modules for alarm systems has been designed specifically to assemble, analyze and test electrical systems of detection and signaling in the field of fire fighting alarm for civil and service sectors. Modules can be inserted in bench to implement the training programme. As an alternative, testing frame can be used and the equipment can be powered by power supply unit (both these units are supplied separately, on demand). TRAINING PROGRAM: fire fighting system including photoelectronic smoke detector and alarm device connected with electronic control unit fire fighting system including rate-of-rise detector and alarm device connected with electronic control unit fire fighting system including photoelectronic smoke detector, rate-of-rise detector and alarm device connected with electronic control unit with OR-AND lines alarm system with gas leak detector alarm system with carbon monoxide detector Technical specifications: The set of modules for implementing alarm systems includes: 1 electronic control unit with 2 lines of fi re alarm and manual alarms, self-powered by 2 buffer batteries x 12 VDC. Power supply: 230 Vac. Output: 24 VDC 1 fire alarm ringer. Power supply: 24 VDC 1 photoelectronic smoke detector. Power supply: 24 VDC 1 rate-of-rise detector. Power supply: 24 VDC 1 electronic gas detector. Power supply: 230 VAC 1 electronic CO detector. Power supply: 230 VAC Supplied accessories: Set of 20 cables with safety plugs (Ø 4 mm) 12

13 IMP-13 C Industrial Installations This system has been designed so that students can assemble, analyze and test a wide range of more and more complex electric circuits; it consists of interchangeable modules; thus merely connecting these modules with each other via flexible leads supplied with the equipment enables to assemble various circuits. Modules are made of insulating material and they represent the support of the necessary devices for implementing the experimental programme, besides offering the graphic representation and standardized electric symbol of the used component; connections are made easier by standardized educational terminals (Ø 4 mm) with high protection degree against accidental contacts. Testing modules for industrial installations The set of modules for industrial installations has been designed specifically to assemble, analyze and test typical installations of industrial sector in wired logic such as motor starting, timed sequential cycles. Training program: controlling a contactor from a point jogging of a contactor separate control of two contactors remote control reverser remote control reverser with block on push-buttons remote control reverser with timer remote control of an elevator (A) star-delta starting starting with stator resistors starting with autotransformer starting with rotor resistances; exclusion with continuous variation remote controlled pole-change switch for 2-winding motors remote controlled pole-change switch for single-winding (Dahlander) motors reverse current braking direct current braking control of a circuit breaker switch keyer changeover switch keyer inverter keyer star/delta starter keyer speed switch keyer control of an elevator (B) sequence lighting of advertising neon signs starting with rotor resistances; exclusion with step variation remote control reverser, star-delta starter emergency/extra power line traffic light system main control of a crane Technical specifications: The set of modules for assembling the industrial installations includes: - 5 board fuse-holders with breakable fuses of 4/6 A - 1 three-phase Graetz bridge V 25 A max. - 1 transformer / V Hz 72 VA - 1 thermal relay for industrial uses with NO-NC auxiliary contacts - 1 electromagnetic contactor for - 1 micro switch for industrial uses industrial uses, coil of 24 Vac - 1 micro switch for industrial uses - 1 delayed relay s, (MBB) coil of 24 Vac - 1 micro switch for industrial uses - 1 auxiliary relay for industrial uses - (BBM) coil of 24 Vac - 1 four-pole switch keyer 16 A 400 V - 3 push-buttons for industrial uses - 1 three-pole changeover switch keyer - 3 lamp sockets for industrial uses with lamps of 24 V - 16 A 400 V - 1 three-pole inverter keyer - 16 A 400 V - 1 star/delta starting keyer - 16 A 400 V - 1 three-pole keyer (pole-change switch for Dahlander motors) - 16 A 400 V - 3 three-phase terminal boards for power circuits - 9 three-phase terminal boards for switching/connecting control circuits - 1 traffic light in miniature with 12 lamps of 24 V Supplied accessories: set of 60 cables with safety plugs (Ø 4 mm) Power supply: 3 x 400 V (3 x 230 V) / PE Hz Recommended accessories: Accessories for completing industrial installations INDUSTRIAL INSTALLATIONS can also be assembled in programmable logic with the integration of a PLC 13

14 IMP-13 D Electro-Pneumatic Systems This system has been designed so that students can assemble, analyze and test a wide range of more and more complex electric circuits; it consists of interchangeable modules; thus merely connecting these modules with each other via flexible leads and hoses supplied with the equipment enables to assemble various circuits. Modules are made of insulating material and they represent the support of the necessary devices for implementing the experimental programme, besides offering the graphic representation and pneumatic, electric symbol of the used component; electrical connections are made easier by standardized educational terminals (Ø 2mm) with high protection degree against accidental contacts. Testing modules for electro-pneumatic systems This set of modules for electro-pneumatic systems has been designed specifically to assemble, analyze and test the typical installations pneumatic and electro-pneumatic. Modules can be inserted in bench to implement the training programme. As an alternative, testing frame can be used and the equipment can be powered by power supply unit (both these units are supplied separately, on demand). Training program: controlling a cylinder by monostable solenoid valve controlling a cylinder by bistable solenoid valve controlling a cylinder by monostable solenoid valve and self-holding circuit temporary storage with prevalent insertion temporary storage with prevalent reset temporary binary counter for circuits with bistable solenoid valve temporary binary counter for circuits with monostable solenoid valve semi-automatic control of a double-acting cylinder by monostable solenoid valve semi-automatic control of a double-acting cylinder by bistable solenoid valve electric control of a cylinder by monostable solenoid valve (anti-repetitiveness) electric control of a cylinder by bistable solenoid valve and impulse relay (anti-repetitiveness) automatic control by monostable solenoid valve and stop pushbutton with return to a0 at the end of the cycle automatic control by bistable solenoid valve and stop and emergency pushbutton with different returns semi-automatic control of a cylinder, with bistable distributor, delayed excitation semi-automatic control of a cylinder, with bistable distributor, delayed excitation and exchange contact semi-automatic movement with limit switch, timer and monostable distributor Technical specifications: The set of modules for implementing electro-pneumatic systems includes: - board fuse-holders with breakable fuses of 4/6 A - transformer / V Hz 72 VA - delayed relay s, coil of 24 VAC - auxiliary relay for industrial uses - coil of 24 VAC - push-buttons for industrial uses - pneumatic switch, pressure controller, pressure gauge and 4-way distributor - double-acting cylinder with electric limit switches - 5/2 monostable solenoid valves 24 VAC - 5/2 bistable solenoid valves 24 VAC - impulse relay (single-pole two-way switch) with coil of 24 Vac. Supplied accessories: set of 50 cables with safety plugs (Ø 2 mm) 10 m of cable (Ø 4 mm) 1 cutter for cable Recommended accessories: Silent compressor Programmable logic with the integration of a PLC 14

15 IMP-06 Station Modules to start an Asynchronous Motor The bench has a 1500 x 750mm, stratified top and a single leg assembly. This singlesided station for one student enables you to quickly test the fittings using the jumper wire technique. Each component is fitted with Ø4mm safety sockets which are compatible with fixed sheath safety leads. Thanks to this design, interconnections can be made very quickly and in complete safety. The side unit encloses actuators behind two engraved front sections. This unit is also used to switch on and protect the study grid, and to switch it off in the case of an emergency. Description Each actuator is identified by a standard symbol engraved on the front surface. Each polarity is attached to a safety terminal set into the front surface. The components are fitted with female safety sockets which allow rapid connection using Ø4 safety leads. These safety sockets make every IP2X part safe for the user. The following equipment can be found on this grid: General power supply module: VCA - 220/380 VCA - single & three phase - Thermal & differential Distribution module Circuit breaker modules: - Type: 4 poles - Rated current: 25A - Release: type C - Breaking current: 10000A Fuse holder device module: - Type: 4 poles - Fuse size: 10,3x8mm 2 Power contactor with auxiliary contact for command circuits: - Contacts: 4 NO - Auxiliary contacts: 1 NO + 1 NC Power contactor with auxiliary contact for command circuits: - Contacts: 4 NO - Temporization: NO + NC work (0,1-30)s Relay, thermal relay et temporization relay: - Type: Thermal - Current setting: 0,63A à 1,00A - Auxiliary contact: 1 NO Digital instruments modules: - Description: Energy analyzer - Display: Digital Fuse holder device module: - Type: Single phase - Fuse size: 5 x 2mm Transformer (module): Single-phase, 220V - 24 V, 150VA Command modules: Triple pushbutton; contact "NC + NO" Command modules: Selectors module (IEP02D; IEP02E; IEP02F) Command modules: Three pushbutton module (Emergency + double pushbutton) Signalization modules: Four led pilot lamp. (2 red, 2 green) 24V Relay, thermal relay et temporization relay: - Type: Temporization - Courant: 16A - Tension: 220V - Temps: 24h 15

16 IMP-03A Asynchronous Motor Start-Up Kit This industrial kit includes actuators and control components for studying and creating the main start-up diagrams for asynchronous motors: direct start-up, with or without reversal of the direction of rotation. star/delta start-up star/delta start-up with reversal of the direction of rotation They are used for connections between the following: cabling plate, pushbuttons, switches, indicator lights motor. A teaching manual including diagrams, characteristics and instructions for each component is supplied with the kit. Composition 25A-400V 4-pole circuit breaker two-pole fuse holder 4-pole fuse holders 9A power contactors with 24V coil auxiliary contactors with 24V coil unit of auxiliary contacts with timing from 1 to 30 s units of auxiliary contacts 1 "O" + 1 "C" 0,63 to 1A thermal relay with support 230V/24V VA single-phase transformer for control circuit plate, dimensions 800 x 800 mm set of pushbuttons, emergency stop and indicator lights for controlling and viewing all operations of the wired frame. IMP-04A Installation Trainer for Lighting To be used for the student to practice in wiring of lighting control circuits with fluorescent and incandescent lamps. Two lighting control circuits are incorporated in this module. In the first circuit, a fluorescent lamp and an incandescent lamp are controlled by an automatic system using a photo-cell operated relay. In the second circuit, a fluorescent lamp and an incandescent lamp are controlled by a manual pushbutton which operates a timing circuit. The kit consists of Earth leakage protection device Circuit breaker Switch, one way Switch, one way, double Wall socket with earth Switch, two way Push buttons Switch, intermediate Time Relay Step-by-Step Relay Lamp holder E27 4 pcs Characteristics Power Supply cable 2P+N 220V Dimensions 580 x 420 x 120mm 16

17 Workstation (for 2 students) SUPPLIED WITH 2 fixed grids Workstation for 2 users. It is delivered with: 2 vertical electrical consoles with various outputs 2 grid frames 2 fixed grids 800 x 800mm 1 stratified bench of dimensions 1200 x 800mm SUPPLIED WITH 4 fixed grids Workstation for 4 users. It is delivered with: 2 vertical electrical consoles with various outputs 4 grid frames 4 fixed grids 800 x 800mm 1 stratified bench of dimensions 2000 x 1000mm 1 storage areas for removable grids (optional) Workstation (for 4 students) Electrical features of the vertical consoles (2 sides) EMERGENCY STOP The push-button cuts off the power in the case of an emergency. Key-resettable (positive safety). 24VAC SUPPLY (insulated from mains) Used via 2 safety terminals. Primary winding of transformer protected by auto-protection and secondary wiring by circuit breaker. GENERAL START/STOP A lamp indicating that the power is on. Key-operated power-on switch.. 230V MAINS DISTRIBUTION Two mains sockets 230V with lamp. GENERAL PROTECTION Protection by thermal magnetic circuit breaker (30mA residual circuit breaker available as an option). 3-PHASE SUPPLY (3 x 400V + N+ E) A lamp indicating that the power is on. Output via 4mm safety terminals. 17

18 SUPPLIED WITH 4 fixed grids Workstation for 4 users. Supplied with: 2 vertical electrical consoles with various outputs 4 grid frames 4 fixed grids 800 x 800mm 1 stratified bench 2000 x 1000mm 2 small ones 1000 x 800mm. 1 storage areas for removable grids (optional) Cross-shaped wiring bench Bench for Panel Bench with three level metal frame for modules for the study of various argument (Electrotechnique, Electronic, Pneumatic, Electric, etc...). 18

19 Power consoles on the bench top Power console with a PVC front panel. Available in a range of lengths mm. 19

20 Elecricite et electronique Controle des procedes Pneumatique et electropenumatique Technologie de l automatisation Installations electriques domotica Electronique de puissance Machines electriques Moteurs et fluides pour machines Systemes industriels d entrainement Maintenance et simulation des pannes sur ordinateur Communications analogiques Realisation de circuits imprimes Montage et reparation circuits imprimes Soudage et equipement Outils Laboratoire de physique Laboratoire de chimie Laboratoire de biologie Instrumentation electronique Instruments electroniques analogiques Instruments electroniques numeriques Instrumentation electrique Electricity and electronics Process control Pneumatics and electropneumatics Automation technology Electrical installations domotic Power electronics Electrical machines Motors and fluids for machines Industrial training systems Fault simulation and maintenance on personal computer Analog communications Printed circuit realisation Printed circuits assembly and repair Soldering and equipment Tools Physics laboratory Chemistry laboratory Biology laboratory Electronics instrumentations Analog electronics instrumentation Digital electronics instrumentation Electrical instrumentation Worldwide Branch Offices OFEL Sarl Algerie OFEL Sarl Maroc OFEL Spain OFEL Mexico OFEL Brazil OFEL USA OFEL Thailand OFEL South Africa Headquarter Via M. Idiomi 1/ Assago - Milan - ITALY Web: Mail: info@ofelitaly.com Web: Mail: info@ofelengineering.it

UEE30811 Q-Tracker Work Tasks

UEE30811 Q-Tracker Work Tasks UEE30811 Q-Tracker Work Tasks UEENEEC020B Participate in electrical work and competency development activities Q-Tracker requirements: 40 hours of practical training. 1. Comply with electrical industry/enterprise

More information

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS CHAPTER 15: TRAINING SYSTEMS FOR ELECTRICAL INSTALLATIONS 527 Training Panel to Electrical Protective Measures 528 Training Panel to Installation Tests

More information

Subject Description Form

Subject Description Form Subject Description Form Subject Code Subject Title Credit Value IC259 IC Training for BSE II 8 Training Credits Level 2 Pre-requisite / Co-requisite/ Exclusion Objectives Nil 1) To provide trainees with

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

Products for printed circuits and prototypes

Products for printed circuits and prototypes Products for printed circuits and prototypes 2 Shears Light boxes Drill UV exposure units Etching machines Other PCB laminates Consumable Accessory PCB Equipments PCB Equipments CUTTPCB - PCB shear/blade

More information

TECHNICAL DATA AND REFERENCE STANDARDS. Essential electrical data* Resistance at test voltage (V) Insulation resistance (MΩ)

TECHNICAL DATA AND REFERENCE STANDARDS. Essential electrical data* Resistance at test voltage (V) Insulation resistance (MΩ) General characteristics Modular range of devices for domestic and similar uses on frames for flush-mounting boxes of up to 8 modules. It includes controls, socket-outlets, protections, indicators, connectors

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. L Type Anchor Bolt Carbon Steel AISI 304 S.S. ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut

More information

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,

More information

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements INDEX 1 NETIC... 2 2 Door/Window detector MINI... 2 3 FOUR sensor... 3 4 Smoke detector... 3 5 Flood detector... 4 6 ILLumination sensor... 4 7 Lamp holder... 5 8 Siren... 5 9 Power meter & switch... 6

More information

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions GRUNDFOS INSTRUCTIONS LCD 08 Installation and operating instructions Installation and operating instructions Original installation and operating instructions CONTENTS Page. Symbols used in this document.

More information

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components

More information

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION REFRIGERATION AND AIR CONDITIONING CUSSONS LABORATORY RECOMMENDATION Cussons Refrigeration laboratories are offered to provide teaching to a range of different skill levels. In all the laboratories teaching

More information

C19 UNIVEX. High Vacuum Experimentation Systems UNIVEX 300, UNIVEX 450 UNIVEX 350, UNIVEX 450 B Special plants

C19 UNIVEX. High Vacuum Experimentation Systems UNIVEX 300, UNIVEX 450 UNIVEX 350, UNIVEX 450 B Special plants C19 UNIVEX UNIVEX 300, UNIVEX 450 UNIVEX 350, UNIVEX 450 B Special plants Contents General Applications and Accessories / Process Components.............................. C19.02 General................................................................

More information

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd. F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components

More information

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY SECTION 22 11 23.13 DOMESTIC WATER PRESSURE BOOSTING PART 1 - GENERAL 1.1 SUMMARY A. Where utility water pressure cannot adequately meet the pressure requirements of the domestic water systems and where

More information

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II Installation and application Leakage detectors, CLS/FLS/FLS/MiniCAS II INTRODUCTION A number of condition monitoring sensors are available for the ITT FLYGT pump range. Thermal switches for stator over

More information

Innovative EEE mini-projects list

Innovative EEE mini-projects list 1 Innovative EEE mini-projects list SEM-133. Checking and auto control of water level using wireless sensor. SEM-140. Wireless 3-phase motor starter using RF technology. SEM-185. Designing of Haptic Keypad

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1-316-832-4357

More information

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

LEVEL SWITCH NV-2T v2.1 Installation instructions Order. no: 13169

LEVEL SWITCH NV-2T v2.1 Installation instructions Order. no: 13169 LEVEL SWITCH v2.1 Installation instructions Order. no: 13169 Description The is intended for dynamic lighting control using dimmable light fittings with control, in order to reduce the lighting time for

More information

BSR Addressable Fire Detection control panel. Installation operation manual

BSR Addressable Fire Detection control panel. Installation operation manual BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24 Refrigeration / Air Conditioning Systems Circuit Drawings Nominal Student Hours: Student Resource Package No: NR 24 24 Hours. Delivery: Recognition of Prior Learning: Package Purpose: Suggested Resources:

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET Candidate Code No. EIN 11 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER THEORY EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS

More information

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction. Introduction The UL listed Phone-A-Stat (model # 7632 ) is designed and approved for the safe operation of remotely controlling four independent loads, such as a sprinkler system or a water heater via

More information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required

More information

EDUCATIONAL TRAINING UNITS

EDUCATIONAL TRAINING UNITS S OUR COMMITMENT TO QUALITY EDUCATION At Imperial Training we strongly believe in providing the HVAC/R student with the knowledge & training for the safe and efficient operation of all types of systems

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx: UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK 40 Dale Street West Babylon, NY 11704 Ph: 631-753-9550 Fx: 631-753-9560 www.unionconnector.com Emergency Automatic Transfer System STANDARD SPECIFICATIONS

More information

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 INTRODUCTION Thank you for purchasing the Hokkim Integrated Automatic Mains Failure Control Board model HAMF- 8 or HAMF-4. We shall

More information

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately

More information

7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module 7800 SERIES RM7888A Relay Module SPECIFICATION DATA FEATURES APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically

More information

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING TRA DITIONS AND INNOVATION Since 1922 The first LOVATO Electric headquartes founded in Bergamo in 1922: the starting point of the grand industrial

More information

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2

More information

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual This manual covers operation of the tcm100 and tcm101 Series Temperature Control Modules.

More information

Refrigerator KE T

Refrigerator KE T Refrigerator KE 680-1-3T Service Manual: H8-74-07 Responsible: U. Laarmann KÜPPERSBUSCH HAUSGERÄTE AG E-mail: uwe.laarmann@kueppersbusch.de Tel.: (0209) 401-732 Customer Service Fax: (0209) 401-743 Postfach

More information

F1202 TRACE HEATING. Road & Ramp

F1202 TRACE HEATING. Road & Ramp Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.

More information

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc. IMR 5000 Operating Manual S/N: For information only! IMR Environmental Equipment Inc. INTRODUCTION 3 SAFETY INSTRUCTIONS 3 SYSTEM DESCRIPTION - IMR 5000 GAS ANALYSIS SYSTEM 4 Function chart IMR 5000 -

More information

User Manual 120/240/300 Outdoor Motion Detector

User Manual 120/240/300 Outdoor Motion Detector User Manual 120/240/300 Outdoor Motion Detector Swiss Garde 4000 Warning! - Any work on the main power supply must only be completed by trained specialists. - The product must be installed in accordance

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-3 ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: For use with doors or groups of doors that must interlock with each other to regulate control of accessing one area from another,

More information

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation The most user friendly Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Security Alarm System L S 4 0 0 Section 2 Planning your Installation 2.1 Location of

More information

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard Detector Wiring Method. 4 Method of Wiring.. 5 Wiring

More information

PANTHER. Condensate removal pump Installation and operating guide

PANTHER. Condensate removal pump Installation and operating guide PANTHER Condensate removal pump Installation and operating guide The PANTHER is a self-contained condensate removal system for use directly inside trunking and highwall-mount air conditioners.the small

More information

CONTROLS INSTRUCTIONS MANUAL ENGLISH

CONTROLS INSTRUCTIONS MANUAL ENGLISH CONTROLS INSTRUCTIONS MANUAL ENGLISH Table of Contents 1. Introduction of the Innova Controls 3 1.1 Precautions 3 2. Operating Instructions 2.1 Quick Start 4 2.2 Direction of Use 5 2.2.1 Heater on 5 2.2.2

More information

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply

More information

Slim Line Service Manual

Slim Line Service Manual Slim Line Service Manual SLIM LINE Juice Machine Din återförsäljare / Your retail dealer S / EN...... Rev. 090914 List Of Contents Index Main Index List of contents page 2 General description page 3 Dispenser

More information

Parts and Service Manual

Parts and Service Manual Section II Parts and Service Manual (70241A) CLARKE TECHNOLOGY Operator's Manual - MINI MAX Page -29- Frame and Front Cover Assembly Drawing 2/01 Page -30- CLARKE TECHNOLOGY Operator's Manual -MINI MAX

More information

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs lighting management - stand alone detectors, power packs 488 03 488 20 488 07 488 06 Pack Cat.Nos Traffic detection - Infrared technology Ceiling mounting detector Set via a thumbwheel 1 488 03 360 - detection

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority. Fitness Facility Addition Page 1 1.1 CODES AND STANDARDS.1 Do complete installation in accordance with the latest edition of the CSA C22.1 as amended by the latest editions of the National Building Code

More information

Multi-Zone Wireless Control Training Systems ( )

Multi-Zone Wireless Control Training Systems ( ) Multi-Zone Wireless Control Training Systems 593306 (3467-00) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 11/2018 Table of Contents General Description 2 Courseware 2 Topic Coverage 3 List

More information

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where

More information

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX MANUAL OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX 1) Technical Specifications: (100VA, 200VA, 300VA) 2) Introduction 3) Construction 4) Operation and maintenance a) Operating Procedure b)

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS Note: This manual may also be used for 6536-871 series heat pumps if the 6535-3209 Replacement

More information

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET EST 2066 Candidate Code No. For Board Use Only Result Date Int Result Date Int ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Two Hours INSTRUCTIONS

More information

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5

More information

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

CAR BURGLAR ALARM K3504

CAR BURGLAR ALARM K3504 CAR BURGLAR ALARM K3504 Low cost reliable car alarm. ILLUSTRATED ASSEMBLY MANUAL H3504IP - 1 Features & Specifications The alarm detects sudden voltage drops of the battery when the interior, trunk, or

More information

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition What it is: The MRD2 'turnout' edition is a two-channel model train detector. It can detect model trains at two

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

FireFlex 1230 Self-contained system

FireFlex 1230 Self-contained system FireFlex 1230 description The FireFlex 1230 integrated system consists of a clean agent fire extinguishing system, factoryassembled in a cabinet and integrating all the components necessary for a complete

More information

7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module 7800 SERIES RM7888A Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically

More information

Fire Alarm Advanced Application AEL-AD3A

Fire Alarm Advanced Application AEL-AD3A Engineering and Technical Teaching Equipment Fire Alarm Advanced Application AEL-AD3A INTRODUCTION Nowadays, alarms are used in a wide range of applications, such as fire detection, reminders or burglar

More information

M2000 Engine Controller

M2000 Engine Controller M2000 Engine Controller Integrated control and protection of diesel and gas engines for all purposes Especially suited for auxiliary generator sets 1 IN OPERATION 1 2 STARTFAIL 2 3 OVERSPEED RPM FAIL 3

More information

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47) DIESEL ENGINE CONTROL UNIT DCU 205 - USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) 64 84 52 00 Fax: (+47) 64 84 52 12 office@auto-maskin.no - 1 - TABLE OF CONTENTS 1. INTRODUCTION TO THE DCU 205...4

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC. WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or

More information

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual Technical Manual Type EC-2 Engine Control Unit 4189340232D DEIF A/S Technical Manual DEIF A/S Tel.: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fax: (+45) 9614 9615 Denmark E-mail: deif@deif.com Contents

More information

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES Articulation Agreement Identifier: ELT 118 (2005-1) Identifier is the postsecondary course prefix followed by Plan-of-Instruction

More information

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN) Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN) Ovens Service Manual Models OMFP6010 CONTENTS This document has been published to be used for service only. The contents

More information

03.03.mmm REV.2 09/01

03.03.mmm REV.2 09/01 03.03.mmm REV.2 09/01 Via del Lavoro, 80-40056 CRESPELLANO (Bologna) ITALY - ( +39 051/733.383 - Fax. +39 051/733.620 P.O. BOX, 150-40011 ANZOLA EMILIA (Bologna) - ITALY Power Factor Regulator cosφ V A

More information

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1 Lodam Compressor Protection Module Technical manual Version 3.0 SE-G1 Contents 1. Read this first... 4 1.1. Reading instructions... 4 1.2. User manual... 4 1.3. Safety... 4 2. General... 5 3. Definitions...

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR

OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR IBIS INTERNATIONAL Thank you for purchasing the KP4041 Poly Scrap Compactor. IBIS appreciates your confidence in our product, and promises to support its operation

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS - Wall-mount indoor unit - OPERATING LIMITS Cooling Maximum conditions Heating Maximum conditions Outdoor temperature : 122 F (50 C) D.B. Outdoor temperature : 75 F (24 C) D.B.

More information

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1. Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction

More information

Monitoring Devices 11/1

Monitoring Devices 11/1 11/4 Introduction 11/6 5TE5 8 light indicators 11/7 4AC3 0, 4AC3 1 bells, buzzers 11/7 5TT3 46 fault signaling units 11/8 7LQ2 1, 5TT3 3 dusk switches 11/9 7LQ2 0 temperature controllers 11/9 5TT3 170

More information

Indirect gas-fired air heater

Indirect gas-fired air heater Indirect gas-fired air heater SERIES HD INSTALLATION AND SERVICE MANUAL MANUFACTURED BY : BROTHERS LIMITED WARNING Improper installation, modification, adjustment or maintenance may cause damage, injury

More information

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR -SQA- SCOTTISH QUALIFICATIONS AUTHORITY Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR -Module Number- 4280130 -Session-1990-91 -Superclass- XJ -Title- GAS SERVICES:

More information

EXTINGUISHING CONTROL PANEL PX2 SERIES

EXTINGUISHING CONTROL PANEL PX2 SERIES EXTINGUISHING CONTROL PANEL PX2 SERIES AE/PX2 AE/SA-PX2 AE/94-PX2 USER MANUAL VERSION 1.0 APR/2007 CONTENT PAGE 1 INTRODUCTION...3 1.1 PURPOSE OF THE MANUAL... 3 1.2 REMARKS... 3 1.3 WARNINGS AND PRECAUTIONS....

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

Carbon Dioxide Fire Suppression Systems

Carbon Dioxide Fire Suppression Systems Carbon Dioxide Fire Suppression Systems The original "clean agent," carbon dioxide suppresses fire without leaving behind water, foam or dry chemical to damage sensitive equipment. And because there is

More information

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE ANSUL INSTALLATION OPERATION AND MAINTENANCE MANUAL ANSUL AUTOMAN II-C RELEASING DEVICE 001799 This manual is intended for use with the ANSUL AUTOMAN II-C Releasing Device. Those who install, inspect,

More information

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps TT-1023 1/97 INSTALLATION INSTRUCTIONS Original Issue Date: 2/94 Model: 6-2000 kw Market: Industrial Subject: Flush- or Surface-Mount Remote Annunciator Kits PA-293991 and PA-293991-SD The remote annunciator

More information