MAIN MENU/HOME SCREEN OVERVIEW
|
|
- Dina Neal
- 5 years ago
- Views:
Transcription
1 s Sensor (S11) 3038 µs/cm 77.1 F Generic AI (S21) 30.5% Generic AI (S22) 37.9% List of possible s: Contacting Conductivity Electrodeless Conductivity Temperature ph ORP Disinfection Generic Transmitter/AI Monitor DI State Flow Meter, Contactor type Flow Meter, Paddlewheel type Feed Monitor Virtual Calculation Virtual Raw Value MAIN MENU/HOME SCREEN OVERVIEW HOME SCREEN (example) CCond SENSOR (S11) (S1) 3041 µs/cm 77.0 F MAIN MENU s Additional Confg Settings: Remote Communications (Modbus) On/ (R1) Flow Timer (R2) Alarm R1 R2 R3 R4 R5 R6 List of possible : On/ control mode Flow Timer control mode Percent Timer control mode Alarm Output mode Time Proportional control mode Manual control mode Pulse Proportional control mode PID control mode Dual Setpoint mode Timer control mode Probe Wash control mode Spike control mode Lag Output control mode Analog Ouput, Retransmit mode Analog Output, Proportional control mode Analog Output, PID control mode Analog Output, Manual mode Analog Output, Flow Proportional mode List of all Active To HOME SCREEN Settings Sensor DI Relay Low Axis Limit High Axis Limit µs/cm Nov Time Range 10 SENSOR Minutes(S1) 30 Minutes 1 Hour 2½ Hours X Hand Auto CCond (S11) On/ (R2) 10 Minutes Additional Settings: Time Range More possible settings: 8 Hours 1 12 Hours 2 s 1 4 s ½ 35
2 s Sensor (S11) 3038 µs/cm 77.1 F Generic AI (S21) 30.5% Generic AI (S22) 37.9% s Calibration One Point Process Calibration One Point Buffer Calibration Two Point Buffer Calibration Three Point Buffer Calibration One Point Analog Calibration Two Point Analog Calibration Open Air Calibration (Cond) Zero Calibration (Disinfection) ssensor (S11) sensor type INPUTS Contacting Cond S11 (22) Additional Settings for Contacting Conductivity: Units Temp Compensation Temp Comp Factor Cell Constant Transmitter S11 (S12,13,21,22,23) AI Monitor S11 (S12,13,21,22,23) Additional Settings for Transmitter and AI Monitor: Units 4 ma Value 20 ma Value Electrodeless Cond S11 (S21) Additional Settings for Electrodeless Conductivity: Cell Constant Installation Factor Units Range Temp Compensation Temp Comp Factor Fluorometer S11 (12,13, 21,22, 23) Additional Settings for Fluorometer: Max Sensor Range Dye / Product Ratio Temperature S12 (S22) ph S11 (S21) ORP S11 (S21) Disinfection S11 (S21) Generic S11 (S21) Additional Settings for Temperature Sensor: Element Additional Settings for ph Sensor: Electrode Buffers (ph only) Additional Settings for ORP Sensor: Additional Settings for Disinfection Sensor: Sensor Additional Settings for Generic Sensor: Units Sensor Slope Electrode (Linear Sensor set or Ion Selective) Low / High Range Calculation (V1-V2) 2 Raw Value (V1-V2) DI State (D1-D6) Open SENSOR Message (S1) Closed Message Interlock Alarm Paddlewheel Flowmeter (D1-D6) Totalizer Alarm 36 Contactor Flowmeter (D1-D6) Totalizer Alarm Feed Monitor (D1-D6) SENSOR Totalizer (S1) Alarm Additional Settings for Virtual Calculation Low Range High Range Additional Settings for Raw Value: Smoothing factor Additional Settings for DI State: Total Time Additional Settings for Contactor, Flowmeter: Volume/Contact Flow Units Additional Settings for Paddlewheel, Flowmeter: K Factor Flow Units Rate Units Additional Settings for Feed Monitor: Total Alarm Flow Units Flow Alarm Rate Units Flow Alarm Delay Flow Alarm Clear Output Reprime Time Volume/Contact VIRTUAL INPUTS DIGITAL INPUTS
3 On/ (R1) Inhibitor (R2) On/ (R1) output type On/ (R1-R6) Flow Timer (R1-R6) Feed Accumulated Volume Bleed & Feed (R1-R6) SENSOR Setting (S1) Feed Time Limit Bleed then Feed (R1-R6) SENSOR (S1) Feed Percentage Feed Time Limit Reset Timer Percent Timer (R1-R6) SENSOR (S1) Sample Period Feed Percentage Alarm (R1-R6) SENSOR Setting (S1) Alarm Select Output Biocide Timer (R1-R6) SENSOR Setting (S1) s Additional Settings for On/OFF : Delay Time Additional Settings for Flow Timer : Flow Flow 2 Additional Settings for Bleed & Feed : Bleed Additional Settings for Bleed then Feed : Bleed Additional Settings for Percent Timer : Additional Settings for Biocide Timer : Bleed Prebleed Time Prebleed To Cond Bleed Lockout Add Last Missed Additional Settings for Alarm : Int. Sampling (R1-R6) Manual (R1-R16) Delay Time Pulse Prop (R1-R6) SENSOR Setting (S1) Minimum/Maximum Output PID Control (R1-R6) SENSOR Setting (S1) Gain Proportional Gain Dual Setpoint (R1-R6) 2 Timer Control (R1-R6) SENSOR (S1) Hourly Events Per Probe Wash (R1-R6) Hourly Events Per Spike Control (R1-R6) Set point Spike Set point OUTPUTS (RELAYS R1-R6) Additional Settings for Intermittent Sampling : Sample Time Min Relay Cycle Hold Time Maximum Blowdown Wait Time Cond Trap Sample Additional Settings for Manual : Additional Settings for Pulse Prop : Maximum Rate Additional Settings for PID Control : Integral Time Integral Gain Minimum Derivative Time Maximum Derivative Gain Gain Form Reset PID Integral Minimum Output Maximum Output Maximum Rate Additional Settings for Dual Setpoint : Delay Time Additional Settings for Timer Control : Add Last Missed Additional Settings for Probe Wash : 2 Sensor Hold Time Additional Settings for Spike Control : Event 1 (through 8) Time Prop (R1-R6) Sample Period Additional Settings for Time Prop : Lag Control (R1-R6) Lead Wear Leveling* Wear Cycle Time* Additional Settings for Lag Control : Activation * Min Relay Cycle 2 Delay Time* * See section
4 OUTPUTS (ANALOG A1-A2) On/ (R1) Inhibitor (R2) s On/ (R1) output type Retransmit (A1-A2) 4 ma Value 20 ma Value Additional settings for Retransmit : Proportional Control (A1-A2) Min Output PID Control (A1) Gain Proportional Gain Manual Control (A1-A2) Additional Settings for Proportional Control : Max Output Output Additional Settings for PID Control : Integral Time Integral Gain Derivative Time Output Derivative Gain Reset PID Integral Min Output Max Output Max Rate Minimum Maximum Gain Form Additional Settings for Manual Control : Flow Prop (A1-A2) Target Pump Capacity Pump Setting Lag Output (A1-A2) Lead Additional Settings for Flow Prop Control : Specific Gravity Flow Output Additional settings for Lag Output : Wear Leveling Wear Cycle Time 38
5 HOME SCREEN (example) CCond (S11) 3041 µs/cm 77.0 F CONFIG MENU s Date Time Location Controller Log Out Security Local Password DHCP SENSOR Setting (S1) Controller IP Address Network Netmask Network Gateway SENSOR (S1) DHCP Status Controller IP Address Network Netmask Remote Communications SENSOR Comm (S1) Status Data Format Data Port Verbose Logging Additional : Global Units Temperature Units Alarm Delay HVAC s Language Additional : DNS Server TCP Timeout VTouch Status LiveConnect Status Update Period Reply Timeout Additional : Network Gateway DNS Server MAC Address Last VTouch Data Last VTouch Home 1 Home 2 Home 3 Home 4 File SENSOR Transfer (S1) Status Data Log Range Log Frequency Export Data Log File Controller Product Serial Number Controller Board Additional Settings: Remote Communnications (Modbus) Additional : Home 5 Home 6 Home 7 Home 8 Adjust Display Key Beep Auto Dim Time Additional : Export Event Log Export System Log Export User File Import User File Restore Default Software Upgrade Additional : Power Board Sensor Board #1 Sensor Board #2 Network Board AO Board Last Data Log Battery Power Internal Temp 1 Internal Temp 2 Internal Temp 3 Internal Temp 4 +5 Volt Supply +3.3 Volt Supply LCD Bias Voltage LCD Supply Report SENSOR #1 (S1) through #4 Adresses Server SMTP Server Additional : SMTP Port From Address ASMTP Username ASMTP Password Report #1-4 Settings: Report Recipients (Datalog/Summary Reports) Reports Per (Datalog/Summary Reports) (Datalog/Summary Reports) of Month (Datalog/Summary Reports) Report Time (Datalog/Summary Reports) Log Frequency (Datalog Report) Alarm ( Report) Select ( Report) Alarm Delay ( Report) 39
Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller
Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller ProMtrac_Browser_Manual.docx (5/23/13) rev1: pn. 7501088 Please completely read through these operating instructions first! Do
More informationWCT/WBLW100 Series. Instruction Manual. Cooling Tower and Boiler Controller. Five Boynton Road Hopping Brook Park Holliston, MA USA
WCT/WBLW100 Series Cooling Tower and Boiler Controller Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 WEB: www.walchem.com otice 2015 WALCHEM, Iwaki America
More informationCONTENTS. Safety. 4. NOBODY READS THIS STUFF 4.1 Spare Parts 4.2 Technical Support 4.3 Specifications 4.4 Keypad Navigator.
CONTENTS Safety 1 STUFF YOU DO MOST OFTEN 11 What s Happening Now 12 Checking & Clearing Alarms 13 Checking & Changing Setpoints 14 Calibrating Sensors 15 Changing Biocide Timing 16 Adjusting % Feeds 17
More informationA36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS
SCADA INTERFACE INSTRUCTIONS - OPTION 21Q - FOR A36D/TPSD SYSTEMS with 500 and 550 option. A36D/TPSD Modbus TCP SCADA INTERFACE OPTION 21Q INSTRUCTIONS This manual is valid for A36D/TPSD Chargers equipped
More informationController Specification Sheet
Controller Specification Sheet MC9550ABXXBX Proportional Inhibitor Dosing, Dual Conductivity Bleed Control, Dual Point ph Control, Redox Control of Oxidising Biocide and Secondary Biocide Dosing PULSAtrol
More informationmultiflex M10 and M5 User Manual
multiflex M10 and M5 User Manual 11 M714_User_Masterdoc Updated Aug 25, 2015 2 CONTENTS Safety 1 STANDARD OPERATIONS 4 11 What s Happening Now 12 Checking & Clearing Alarms 13 Checking & Changing Setpoints
More informationUser Guide IM/AX4CO4 Rev. K. AX413, AX430, AX433, AX436 & AX438 Single and dual input analyzers for high level conductivity
User Guide IM/AX4CO4 Rev. K AX413, AX430, AX433, AX436 & AX438 Single and dual input analyzers for high level conductivity The Company We are an established world force in the design and manufacture of
More informationUse this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.
Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description. This document is a framework for creating a specification. It may contain
More informationInstallation & Operating Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller
Installation & Operating Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller ProMtrac_OM.docx (5/23/13) rev1: pn. 7501089 Please completely read through these operating instructions first!
More informationA36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS
SCADA INTERFACE INSTRUCTIONS - OPTION 21S - FOR A36D/TPSD SYSTEMS with option 500 and 550. A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE OPTION 21S INSTRUCTIONS This manual is valid for A36D/TPSD Chargers
More informationWebAlert WA500 Series Process Monitor Instruction Manual
W A L C H E M IWAKI America Inc. WebAlert WA500 Process Monitor WebAlert WA500 Series Process Monitor Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 FAX:
More informationTable of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11
Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4.
More informationManual. MicroTron. Tower Controller. Installation Maintenance Repair Manual
Manual MicroTron Tower Controller Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com
More informationInstruction Manual for Water Treatment Controller Model: DIGICHEM Plus + (All software versions to 0.91)
Instruction Manual Instruction Manual for Water Treatment Controller Model: DIGICHEM Plus + (All software versions to 0.91) Fill in serial number here Refer to back page Supplied by: Convergent Water Controls
More informationSlimFlex microflex: HELP
HELP Links The first line of the controller LCD display may display a help number?123 where 123 is a HELP number from 010 to 255. Example: LCD Displays Off@ 995?121 ON 1299uS?121 The Bleed Solenoid is
More informationModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.
ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page
More informationCELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL
Operation Manual Celltrol II Bioreactor Control System Page 1 of 33 Table of Contents 1) Introduction... 3 1.1) Scope of Document... 3 1.2) Control System Overview... 3 1.3) Introduction to Celltrol II...
More informationSetup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software
La Marche Manufacturing Company www.lamarchemfg.com DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for A36D & TPSD Chargers with S2A-341S and S2A-383S communication cards. Option 21P,
More informationModbus TCP/IP Option Instruction Manual
W A L C H E M An Iwaki America Company WebMaster Modbus TCP/IP Option Web Master WIND Modbus TCP/IP Option Instruction Manual s825v008 and higher Five Boynton Road Hopping Brook Park Holliston, MA 01746
More informationDCM200 Aquatics Controller. Keypad Navigation
DCM200 Aquatics Controller Pool 750 mv 7.49 ph 81.1F Keypad Navigation BACK Button. In navigation screens, used to go back 1 level. NOTE: In Output Status Screens 1-9, BACK is used to change output HOA
More informationBacnet Room Setpoint & Temp Display. Descriptions. Specifications
Descriptions Bacnet Room Setpoint & Temp Display is designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used to monitor air temperature
More informationLUFKIN WELL MANAGER MODBUS MAP
LUFKIN WELL MANAGER MODBUS MAP RPC APPLICATION DATE: VERSION: REVISION: FIRMWARE VERSION: 1/30/2012 6.16 6.16 Lufkin Automation Page 2 of 104 Revision History Revision Date 0.01 5/7/01 0.02 5/8/01 0.03
More informationEKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5
More informationTHX-DL Data Logger USER & INSTALLATION MANUAL V
THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power
More informationPowerLogic ION Setup Meter Configuration Software Configuration Guide
PowerLogic ION Setup Meter Configuration Software Configuration Guide 70002-0293-03 12/2010 Conventions Used in this Manual This section describes the symbols and terminology used in this guide. Symbols
More informationMultiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options
Table 4 External Maintenance Switch Configuration Options External Maintenance Switch Options Installed with Interlock Option Option Auxiliary Contact Status open = On Test position or Maintenance position,
More informationAquaLynx 200 ADX. Monitoring and Control System. Background. Operation
AquaLynx 200 ADX Monitoring and Control System The RODI Systems AquaLynx 200 ADX is a unique monitoring system for water treatment applications. The AquaLynx 200 ADX offers a dependable yet affordable
More informationTC-9102 Applications
Application Note January 7, 2004 APPLICATION NOTE TC-9102 Applications Configuring TC-9102 Applications...3 Introduction... 3 Key Concepts... 4 TC-9102 Controller... 4 Control Modes...8 Procedure Overview...
More informationMYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7
MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7 VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIAD DPC MANUAL 013114 1 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features
More informationORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset
Instruction Manual ORP (mv) Controller Model: ORP-XP2 Power Control Alarm Comms UP DOWN ENTER Time & Date Main Menu Alarm Reset Supplied by: Convergent Water Controls Pty Ltd 2/4 Huntley Street, PO Box
More informationSeries 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.
MISSION CRITICAL Air Conditioning Systems Series 9 Commissioning Checklist S9-CL2017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 S9-CL2017.doc Commissioning
More informationAlarm module for leak detection with webserver
This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer
More informationSEQUENCE OF OPERATIONS
SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,
More informationPH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS
FEATURES DESCRIPTION The model 223pH / ORP Transmitter is ideal for use where economy and reliability are the prime considerations. The basic transmitter is available with either a 115VAC, 220VAC or 24V
More informationSequence of operation
Sequence of operation IPS 4000 secondary variable speed control File No: 90.96 Date: february 21, 2013 Supersedes: new Date: new sequence of operation ips 4000 2 list of abbreviations: adj: Field Adjustable
More informationExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet
ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet DataSheet ev 1.2.008/4.1 July 30, 2013 Operating Sequence Standard Occupied During normal occupied operation the display will show
More informationMicroVision MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation Operation Manual Rev. N Page 1 of 43
MicroVision MICROPROCESSOR BASED WATER TREATMENT CONTROLLER Installation Operation Manual Page 1 of 43 Table of Contents 1. INTRODUCTION... 4 2. MICROVISION FEATURES... 4 2.1 Toroidal Probe... 4 2.2 Output
More informationCorporate Profile. needs and product demands. CON 08X /03 Rev 0
Corporate Profile A leader in the field of electrochemical instrumentation, Eutech Instruments is a dynamic company rapidly positioning itself globally as a leading manufacturer of electrochemical instrumentation
More informationImportant Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.
1 P age Ezeio v9-120317 Eze Cloud Based Monitoring Systems. Created by Intech Instruments Ltd December 2014 Important Supplementary Manual to the main Ezeio manual. Ezeio Controller and the 2400-A16 input
More informationUser Guide UTI-IQCP. Control panel for setting and monitoring of UTI-INV internal temperature regulator. v EN
User Guide UTI-IQCP Control panel for setting and monitoring of UTI-INV internal temperature regulator v. 1.06 EN 1. MAIN DISPLAY SCREEN The main display screen is divided into five basic monitoring windows
More informationUser Manual System 11
User Manual System 11 www.pulseinstrument.com Copyright 2007 Pulse Instruments All Rights Reserved 943 Flynn Road, Camarillo, CA 93012 Phone: (800) 462-1926 Fax: (800) 878-9172 SYSTEM 11 Water Disinfection
More informationOperation Manual Fighter ProVision Software. Version: 0.0 Revision: 1
Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User
More informationOVEN INDUSTRIES, INC.
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and
More informationPULSAFEEDER MODEL 3210 MICROPROCESSOR-BASED CONDUCTIVITY CONTROLLER INSTALLATION & OPERATION MANUAL SERIAL #:
PULSAFEEDER MODEL 3210 MICROPROCESSOR-BASED CONDUCTIVITY CONTROLLER INSTALLATION & OPERATION MANUAL SERIAL #: Table of Contents 1 1.0 Introduction... 1-4 1.1 FEATURES... 1-4 1.2 BENEFITS... 1-4 2 Specifications...
More informationManual for the integration in BMS/GTC
Manual for the integration in BMS/GTC Communication parameters MODBUS RTU and BACNET COMMUNICATION UTBS PRO-REG Software Version 3.6 EN ÍNDEX 1. GENERALITIES...2 1.1. Introduction...2 1.2. signals types...2
More informationMYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL
MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TPC VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIADI&O062705 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 7,8
More informationHIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER
This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER
More informationVERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER
1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning
More informationHumidity Controller Specification and Installation Instructions. Model HRO20
Model Description The Humidity Controller is an advanced application to control relative humidity for general purpose applications. They are specially designed to control humidifiers and dehumidification
More informationFlow Level Pressure Temperature. Rugged tactile response keys. Try the all new Fluidwell Configurator at:
Fluidwell F-Series Flow Level Pressure Temperature Trend indication Displayed function Clear 0.7 or 1 digits Measurement units for TOTAL Large LCD with backlight option NEMA 4X aluminum or plastic field
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C
ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C DataSheet ev 1.10.403/4.02 November 6, 2012 Operating Sequence Standard Occupied During
More informationInnovative Circuit Technology Ltd.
Innovative Circuit Technology Ltd. Dual Bus Distribution Panel Series INSTRUCTION MANUAL 855-314-000 Models: ICT200DF-12IRC ICT200DB-12IRC WARNING Risk of serious personal injury or damage to equipment
More informationModels AX410 and AX411 Single and Dual Input Conductivity Analyzers
AX400 Series User Guide Models AX410 and AX411 Single and Dual Input Conductivity Analyzers Incorporating Models AX450 and AX455 To Meet United States Pharmacopeia (USP 645) Regulations ABB The Company
More informationNetworkAIR AFX. Operation and Maintenance AFX65 AFX18
NetworkAIR AFX Operation and Maintenance AFX65 AFX18 Contents Operation... 1 Display Interface.......................................... 1 Using the Display......................................... 3
More informationExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling
ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling DataSheet ev 1.12.304/4.0 June 14, 2016 Operating Sequence
More informationRSC 1000 User Manual. Rev /25/16
RSC 1000 User Manual Rev 2.2 10/25/16 CRITICAL APPLICATIONS DISCLAIMER QUEST CONTROLS PRODUCTS ARE NOT INTENDED OR AUTHORIZED FOR USE IN ANY APPLICATION THAT REQUIRES FAIL-SAFE OPERATION, OR ANY SYSTEM
More informationK-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform
Versa IC Platform VERSA IC Integrated Control Platform Raypak s VERSA IC combines modulating temperature control, safety limits, and ignition programming into one user- friendly Integrated Control Platform.
More informationLC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT
LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT Simply Features In Brief Telemetry Ready Security 2 or 3 Pump Control UL Listed Alarm/Event Log Volumetric Flow Calculator VFD Control Optional Dialer
More informationHIGH CAPACITY PRODUCT LINE
HIGH CAPACITY PRODUCT LINE Highest Quality, Best Service Manufacturing chlorination equipment and related products since 1978 PROUDLY MADE IN USA 600 Emlen Way, Telford, PA 18969 Telephone: (215) 799-0980
More informationFollett Performance Plus
Follett Performance Plus touchscreen user guide The next level of control in undercounter refrigeration Controller Operation - Performance Plus touchscreen Use and care of the LCD Performance Plus touchscreen
More informationOPERATION AND MAINTENANCE MANUAL. Electrode Steam Humidifier Nortec EL Series
2582954_C_EN_1611 IMPORTANT! Read and save these instructions. This manual to be left with the equipment. OPERATION AND MAINTENANCE MANUAL Electrode Steam Humidifier Nortec EL Series Humidification and
More informationMicroTech Series-200 Flooded Screw Chiller
Open Protocol Data Infomation Packet Version 1.0 Group: Controls Date: February 1997 MicroTech Series-200 Flooded Screw Chiller Open Protocol Data Communications 2002 McQuay International - C O N F I D
More informationCDR-AL Room CO 2 Traffic Light Alarm Units and Sensors
Product sheet SN1.402 Type CDR-AL CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors CDR-AL sensors are designed to detect carbon dioxide concentration and temperature in the room spaces. The units
More informationInnovative Circuit Technology Ltd.
Innovative Circuit Technology Ltd. Dual Bus Distribution Panel Series INSTRUCTION MANUAL 855-314-000 Models: ICT200DF-12IRC ICT200DB-12IRC WARNING Risk of serious personal injury or damage to equipment
More informationExcellence through Versatility
Controllers Excellence through Versatility Located in Acton, Massachusetts, Liquid Metronics has been providing quality products and service to the water treatment industry worldwide for over 20 years.
More informationTEMPERATURE CONTROL MODULE MODEL R3-TC2
INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...
More informationPWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014
Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was
More informationFan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication
Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication Description The TFHB24F3XYZ1 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications.
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationOPERATING MANUAL Enertronic Control System 2
OPERATING MANUAL Enertronic Control System 2 The integrated control system for Lennox chillers in the Ecologic range Manufacturer: Lennox Benelux B.V. Postbus 1028, 3860 BA NIJKERK Watergoorweg 87, 3861
More informationMEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2
APT4000 Series 4-Wire Contacting Conductivity Analyzers Overview 70-82-03-45 10/03 Page 1 of 8 Specification The Honeywell Analytical Process Analyzer (APT) 4000 Series2 continuously measures conductivity,
More informationManual. Model GF. Digital Glycol Feeder with MegaTron XS Controller. Installation Maintenance Repair Manual
SET UP ENTER RUN HOME CANCEL HELP ACK Manual Model GF Digital Glycol Feeder with MegaTron XS Controller 1 2 3 4 5 6 7 8 9 0 Installation Maintenance Repair Manual Advantage Controls P.O. ox 1472 Muskogee,
More informationCarbon Monoxide Transmitter
Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or
More informationNGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1
NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...
More informationLift Station Level Controller
Lift Station Level Controller Installation and Operation Manual 1 California Motor Controls, Inc. Benicia, CA Table of Contents 1. Features Product Overview... 4-6 Access Security... 7 Optional Features...
More informationPressurized Condensate Return System (PCR)
(PCR) For use with SKD Direct Steam Injection Humidifiers READ AND SAVE THESE INSTRUCTIONS PCR Manual-180411-R2-ESL Neptronic Company Overview Foreword and Safety Instructions Founded in 1976, we re a
More informationInstruction manual. Analyt 2 / Analyt 3
Instruction manual Measurement, control and dosing device for swimming pools Analyt 2 / Analyt 3 1 Contents 1 OVERVIEW... 5 1.1 Analyt 2 and Analyt 3...5 1.2 Maintenance program...5 1.3 Overview of features...5
More informationManual. Model GF. Digital Glycol Feeder with MegaTron XS Controller. Installation Maintenance Repair Manual
SET UP RUN ENTER HOME CANCEL HELP ACK Manual Model GF Digital Glycol Feeder with MegaTron XS Controller 1 2 3 4 5 6 7 8 9 0 Installation Maintenance Repair Manual Advantage Controls P.O. ox 1472 Muskogee,
More informationEnd To End Optical Beam Smoke Detector. Additional Information
End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important
More information*IG1583EW* Aurora Touch UPC Kit Instruction Guide. Aurora Touch UPC Kit Instruction Guide
Aurora Touch UPC Kit Instruction Guide For use in single compressor water-to-air equipment utilizing fi rmware UPCSWASTD01-01 Aurora Touch UPC Kit Instruction Guide *IG1583EW* IG1583EW 08/14 Aurora Touch
More informationMicroTech Series 200 Centrifugal Chiller
Protocol Data Information Packet Version 2.2 Group: Controls Date: March 1999 MicroTech Series 200 Centrifugal Chiller Data Communications Packet for Protocol 2002 McQuay International Revision History
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationTELSEC MINI PRO User Guide
TELSEC MINI PRO User Guide Rev 1.6 10/25/16 CRITICAL APPLICATIONS DISCLAIMER QUEST CONTROLS PRODUCTS ARE NOT INTENDED OR AUTHORIZED FOR USE IN ANY APPLICATION THAT REQUIRES FAIL-SAFE OPERATION, OR ANY
More informationMC4000 Series Advanced Solid State Dual Unit Lead/Lag Controller with Ethernet Remote Communication Option
MC4000 Series Advanced Solid State Dual Unit Lead/Lag Controller with Ethernet Remote Communication Option The MC4000 has 2 stages of cooling control available for each connected air conditioner. It is
More information1 4 DIN Dissolved Oxygen Controller
16. Warranty OAKTON warrants this controller to be free from significant deviations in material and workmanship for a period of one year from date of purchase. If repair or adjustment is necessary and
More informationA77 SNMPv1 SCADA INTERFACE INSTRUCTIONS
A77 SNMPv1 SCADA INTERFACE OPTION 21X INSTRUCTIONS This manual is only valid for A77 Chargers equipped with the following: S2A-368S card with software version P368S0111 080116 MIB file P389S-21X4-00 S2A-389S
More informationAHU Control. Operating Instructions V5.00
1177fil HHFlex C/R/P/S AHU Control Operating Instructions V5.00 Contents 1 SAFETY CONSIDERATIONS 5 1.1 General 5 1.2 Avoid Electrocution 5 1.3 Abbreviations used 5 2 CONTROLLER DESCRIPTION 6 2.1 Overview
More informationOPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]
OPERATING MANUAL PCC Controller (PCC-01 and 1-149160G) [PCC-01 shown] www.unipowerco.com 2018 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com
More informationOperator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)
Operator's Manual TABLE OF CONTENTS Firmware Version... 1 Environmental Conditions... 1 Electrical Specifications... 1 Warnings... 2 Section A: Programming the Controller... 3 A 1: Adjusting the Display
More informationInstallation and User Instructions
Installation and User Instructions The Informant is a self-contained alarm and logging device that uses the cellular phone network. Text message alarms are sent up to five cell phones. Events are logged
More informationTotal Solution Sirius Cooling Control Unit (CCU) Sirius CONFIGURATION TOOL. (Windows -based configuration application.)
Sirius CONFIGURATION TOOL (Windows -based configuration application.) All units are at the time of shipment to customer configured ready for operation to a user specific hardware and firmware setup as
More informationMicroVision MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation Operation Manual Rev. E Page 1 of 40
MicroVision MICROPROCESSOR BASED WATER TREATMENT CONTROLLER Installation Operation Manual Page 1 of 40 Page 2 of 40 TABLE OF CONTENTS INTRODUCTION... 5 MICROVISION FEATURES... 5 Toroidal Sensor... 5 Output
More informationIndigoVision Alarm Panel. User Guide
IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE
More informationOakton TEMP 9500 Advanced Multiparameter Controller
Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents
More informationIMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.
IMR 5000 Operating Manual S/N: For information only! IMR Environmental Equipment Inc. INTRODUCTION 3 SAFETY INSTRUCTIONS 3 SYSTEM DESCRIPTION - IMR 5000 GAS ANALYSIS SYSTEM 4 Function chart IMR 5000 -
More informationPoolcontrol DYNAMICS. Operating Instructions for users
2010-530-63 Date: 18.03.2011 (Subject to changes without notice) Applicable to software date 911 and date of manufacture 1110 Operating Instructions for users Operating Instructions Notes: dinotec GmbH
More informationS/601 Controller Installation Manual
Checked Version Release date QA V4.6.5 PC1 EN 02.07.2012 2011 S/601 Controller Installation Manual FLOW CONTROL PC1 - Pump controller Introduction Thank you for using the S/601 flow, batch and pump control
More informationEXPERT TRI-STAR. Temperature controller. User s Manual
Temperature controller r s Manual WARNINGS The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete,
More informationTHX-DL Data Logger USER & INSTALLATION MANUAL V Refrigeration
THX-DL Data Logger USER & INSTALLATION MANUAL V3.2016 www.thermomax-refrigeration.com Refrigeration Contents Presentation PRESENTATION Summary of Features 2 COMMS. AREA INSTALLATION 6.0 Service Screen
More information