Protecting life, environment and property... PRODUCTS 2012 Oil & Gas

Size: px
Start display at page:

Download "Protecting life, environment and property... PRODUCTS 2012 Oil & Gas"

Transcription

1 Protecting life, environment and property... PRODUCTS 2012 Oil & Gas

2 Contents AutroSafe IFG...4 Panels AutroSafe Panel kits AutroSafe Switches... 8 Printer... 9 Panels AutroSafe Spare parts AutroSafe I/O modules Communication OPC server Integrated fire and gas (IFG) modules Cabinets and racks Mounting accessories for cabinets and racks Batteries Power supply units Cables Relays Customer configuration AutroMaster...20 Software licences Software modules Interface modules Software hardcopies Engineering Hardware Loop units...26 Input and output units Control units Detectors Manual call points and release stations Alarm units Door magnet Accessories for loop units Service tools for detection loops Flame detection...44 Flame detectors Accessories Test equipment

3 Gas detection...50 Gas detectors Toxic gas detectors Toxic gas sensor modules Toxic gas transmitters and termination boxes Display units Test equipment all gas detectors Accessories Cable glands/blind plugs Calibration kits Accessories for calibration kits Other detectors...58 Alarmline linear heat detectors Accessories Aspirating detectors Accessories Piping halogen free Beam detectors Accessories OMICRON multilevel alarm systems...64 Level alarm system OAS Vapour alarm system OVS 2.1 OP Gas sampling system OGS 3.1 and OGS Fixed gas detection system OGS Direct gas sampling system OGS 2.1 sampling Water ingress system OAS WI Temperature calibrator OTE-T Pressure calibrator OTE-P202 and OTE-P Stringent control throughout assures the excellence of our products and services. For a complete overview of our approvals, please visit our web site 3

4 AutroSafe IFG the new generation interactive fire and gas detection systems Our task was demanding, yet simple: Take the best fire and gas (F&G) safety system around and make it even better. The new and improved AutroSafe Integrated Fire and Gas (IFG) 4 is designed for the toughest requirements and expands the possibilities of a F&G detection system even further. From offshore platforms to LNG plants to refineries, AutroSafe IFG 4 delivers the most rigorous F&G safety yet. Autronica Fire and Security launched AutroSafe, our high-end fire detection system, in From day one, AutroSafe has proven its unique stability and reliability in more than of installations worldwide, both on- and offshore. AutroSafe IFG 4 provides advanced functionality for a wide range of applications. The system is designed to meet all requirements in the high-end segment of the offshore market. It is certified according to European directives (CPD) requiring EN 54 compliance, and is approved by Factory Mutual (FM) according to NFPA 72. Additionally, the F&G system is approved according to SIL2 requirements by TÜV Nord. Reliable communication is paramount to your safety. That s why we re adding AutroNet to the AutroSafe IFG system, an innovative network solution safeguarding communication between panels. AutroNet ensures a redundant and high-speed network, expanding the reach of the AutroSafe IFG system even further. History proves you can rely on AutroSafe IFG. All existing functionality has stood up to the toughest tests worldwide for more than 10 years. With AutroSafe IFG 4, Autronica has once again taken fire safety to a higher level. has once again taken fire safety to a higher level... 4

5 Architectural example AutroSafe IFG a complete solution for fire and gas detection AutroSafe 4 AutroMaster Ethernet switch AutroNet Ethernet switch Controller Repeater panel Fire alarm control panel Repeater panel Operation panel Autro- FieldBus AL_Com+ loop Standard AutroSafe loop units PowerLoop Flame and gas detectors IS isolator unit AutroSafe IS loop units AL_Com+ loop Standard AutroSafe loop units Autro- FieldBus Fire alarm control panel back-up system Aspiration detector 5

6 Panels AutroSafe 4 The AutroSafe 4 family consists of four different panel types. These are: n Fire alarm control panel, BS-420. BS-420 is the main panel in the AutroSafe family. It can be used as a stand-alone panel as well as part of a network system. All operations, alarm management, indications and other functions within an operation zone are controlled and handled by the panel. The panel is equipped with a display, light indicators, a numeric keypad, a navigation wheel and special function buttons (e.g. Silence Alarms). Loop driver, input and output modules can be connected. An integrated AutroFieldBus interface makes it possible to connect AutroFieldBus equipment to the panel. All AutroSafe systems must include at least one BS-420 panel. n Operator panel, BS-430. As for the BS-420 panel, all operations, alarm management, indications and other functions within an operation zone are controlled and handled by the BS-430 panel. The panel is equipped with a display, light indicators, a numeric keypad, a navigation wheel and special function buttons (eg. Silence Alarms). No loop driver, input or output modules can be connected to this panel. n Controller, BC-420. The BC-420 serves as a connection unit for loop driver modules as well as input and output modules. It is equipped with two light indicators for System Fault and Power. The panel has neither display nor operator buttons. An integrated AutroFieldBus interface makes it possible to connect AutroFieldBus equipment to the panel. n Repeater panel, BU-BV-420. Physical dipswitches on the panel control the BU-BV-420 panel function. As an alarm operation panel it can operate alarms within one or more operation zones. As an information panel no operation of alarms are available. The information panel provides information from one or more operation zones. In addition to the panels the power cabinet BP-405 is a part of the AutroSafe 4 family. The cabinet includes a 5 A power pack (BPS-405) which provides six 24 VDC / 2 A outputs. The input voltage is 115 / 230 VAC and the total maximum power available is 24 VDC / 5 A. An integrated AutroFieldBus interface makes it possible for the power pack to communicate (send fault messages) with the BS-420 or BC-420 panel. The cabinet provides space for two 12 V / 18 Ah batteries (not included). 6

7 Panel kits AutroSafe 4 An AL_Com+ stack can contain up to six loop driver modules (BSD-3xx). By using AutroFieldBus, an additional AL_Com+ stack (with up to six additional loop driver modules) can be added to the system. NOTE! The AutroSafe panels are certified with the AL_Com+ modules mounted inside the panel cabinet. Image Part number Description Including Options 116-KIT-BS-420G 116-KIT-BS-420G2 116-KIT-BC KIT-BC-420G2 Fire alarm control panel kit Fire alarm control panel kit approved acc. to IEC SIL2 Controller kit Controller kit approved acc. to IEC SIL2 Panel front BSV-420G Cabinet UEA-400 Power supply module BSS-310A Communication module BSL-310 Text foils E-2879/GB-G Panel front BCV-420 Cabinet UEA-400 Power supply module BSS-310A Communication module BSL-310 Text foils E-2880/GB-G* Loop driver module BSD-310 Loop driver module H.P. BSD-311 BS-100 loop driver module BSD-330 Output module BSB-310 Output module BSJ-310 Input module BSE-310 Input module BSE-320 Add on controller BS-1342 Dual serial communication ports Loop driver module BSD-310 Loop driver module H.P. BSD-311 BS-100 loop driver module BSD-330 Output module BSB-310 Output module BSJ-310 Input module BSE-310 Input module BSE-320 Integrated fire and gas detection systems 116-KIT-BS-430 Operator panel kit 116-KIT-BS-430G2 Operator panel kit approved acc. to IEC SIL2 Panel front BSV-420 Cabinet UE-1488 Text foils E-2879/GB-G* 116-KIT-BU-BV KIT-BU-BV- 420G2 Repeater panel kit Repeater panel kit approved acc. to IEC SIL2 Panel front BUV-420 Cabinet UE-1489 Text foils E-2880/GB-G* 116-BP-405 Power cabinet Cabinet UEA A / 24 V power unit BPS-405 Available space for 2x12 V / 18 Ah batteries *: Please specify language GB-G when ordering 7

8 Switches A network solution (AutroNet) with more than two panels demands the use of switches. Only Phoenix Ethernet switches are approved and supported by. The type and number of switches depends on the installation/ network construction (no. of panels and distance between panels and switches) Image Part number Description* Current consumption 24 VDC RJ45 ports Fibre optic ports** Operating temperature FL switch LM 5TX 150 ma C FL switch LM 4TX/FX 380 ma 4 1 MM (SC) C FL switch LM 4TX/2FX 400 ma 4 2 MM (SC) C * SFNT = Standard Function, Narrow housing, high Temperature range LM = Lean Managed SFNB = Standard Function, Narrow housing, Basic entry level SFN = Standard Function, Narrow housing ** MM = Multi Mode SM = Single Mode SC = Square Connector (Set and Click, Stab and Click, Standard Connector) 8

9 Switches (cont.) Image Part number Description* Current consumption 24 VDC RJ45 ports Fibre optic ports** Operating temperature FL switch LM 4TX/FX SM 380 ma 4 1 SM (SC) C FL switch LM 4TX/2FX SM 400 ma 4 2 SM (SC) C FL switch SFNB 4TX/FX SM ma 4 1 SM (SC) 0-60 C Integrated fire and gas detection systems * SFNT = Standard Function, Narrow housing, high Temperature range LM = Lean Managed SFNB = Standard Function, Narrow housing, Basic entry level SFN = Standard Function, Narrow housing ** MM = Multi Mode SM = Single Mode SC = Square Connector (Set and Click, Stab and Click, Standard Connector) Printer Image Part number Description 116-BUP-400 Log printer unit for AutroSafe Printer paper 57 x 46 x 13 mm / 25 m 9

10 Panels AutroSafe 3 Image Part number Description Dimensions H x W x D (mm) Notes 116-KIT-BS-310G/ KIT-BS-310G2/200 Fire alarm control panel Fire alarm control panel approved acc. to IEC SIL2 350 x 347 x 193 Stand-alone full fire alarm system; the panel functions as an operator panel for one or more defined operation zones. Alarm management and system profiles are monitored and controlled by the panel. Including power supply unit/battery charger. Printer BUP-311 available. 116-KIT-BS-320G/ KIT-BS-320G2/200 Fire alarm control panel Fire alarm control panel approved acc. to IEC SIL2 350 x 347 x 193 AUTROLON networked full fire alarm system; the panel functions as an operator panel for one or more defined operation zones. Alarm management and system profiles are monitored and controlled by the panel. Including power supply unit/battery charger. Printer BUP-311 available. 116-BS-330G/GB BS-330G2/GB400 Operator panel Operator panel approved acc. to IEC SIL2 350 x 347 x 85 Functions as an operator panel for one or more defined operation zones. Alarm management and system profiles are monitored and controlled by the panel. Printer BUP-311 available. With AUTROLON network 116-KIT-BU-320G/500 Repeater panel 116-KIT-BU-320G2/500 Repeater panel approved acc. to IEC SIL2 350 x 347 x 85 To manage alarms in defined operation zones. AUTROLON network 116-BV-320G/GB BV-320G2/GB500 Information panel Information panel approved acc. to IEC SIL2 350 x 347 x 85 Provides localized information for a defined operation zone. AUTROLON network. 116-KIT-BC-320G/ KIT-BC-320G2/200 Controller Controller approved acc. to IEC SIL2 350 x 347 x 193 Node unit for signals from loop driver units, I/O modules and power supply. Power supply unit/battery charger included. AUTROLON network 10

11 Spare parts AutroSafe 3 Part number 116-BUP-311 Description Printer for BS-310/320/ Printer paper for BUP Printer ribbon ERC09P for BUP EAU-310/B 116-EAU-330/1 116-EAU-330/2 116-EAU EAU-341 AUTROLON communication board Required in distributed (networked) systems. Must be mounted in every BS-320 and BC-320 in the system. Ethernet communication module, coaxial cable For coaxial cable. The board can be mounted in the fire alarm control panel or in the controller. Ethernet communication module, twisted pair cable For twisted pair cable. The board can be mounted in the fire alarm control panel or in the controller. Serial post communication board Required when third party equipment is to be connected to AutroSafe via the AutroCom protocol. Typical applications include fire alarm integration with automation systems, pager systems (via ESPA module), programmable logic controllers (via MODBUS module), telephony, etc. The board can be mounted in any BS-320 or BC-320 unit. AutroFieldBus driver A communication protocol converter between the AutroSafe 3 IFG panel and AutroFieldBus units. Provides a redundant field bus system with a ring loop topology. One AutroSafe 3 panel can have one AutroFieldBus connected. Each AutroFieldBus driver can host up to 31 AutroFieldBus units. The AutroFieldBus cable is normally cat. 5 copper cable. However, fibre-optic cable is possible by use of separate signal converters. Degree of protection: IP20 Integrated fire and gas detection systems 11

12 I/O modules AutroSafe IFG features input and output modules for different applications (monitored alarm loops, servicing relays and LEDs, control inputs, etc.). The modules have the same format, mount onto the panels DIN-mounting rail and plug into one another. Important note on module capacity. Each fire alarm panel/controller contains a power supply module BSS-310A and a communication module BSL-310. The BS-420 and BC-420 panels have space for up to 12 modules totally inside the cabinet. An AL_Com+ stack can contain up to six loop driver modules (BSD-3xx) By using AutroFieldBus, an additional AL_Com+ stack (with up to six additional loop driver modules) can be added to the system. NOTE! The AutroSafe panels are certified with the AL_Com+ modules mounted inside the panel cabinet. Image Part number Description Amplified power output For use in EX zone 2 only Ensures loop communication Monitors short circuits Total outputs Total inputs Monitored outputs Monitored inputs Maximum per panel Notes 116-BSB-310 Output module BSD-310 Loop driver module 6/12 Max. 127 loop units 116-BSD-310/N Loop driver module 6/12 Max. 127 loop units 116-BSD-311 Loop driver module H.P. 6/12 12

13 I/O modules (cont.) Image Part number Description 116-BSD-330 BS-100 loop driver module Maximum per panel Amplified power output For use in EX zone 2 only Ensures loop communication Monitors short circuits Total outputs Total inputs Monitored outputs Monitored inputs 8 Notes If more than 3 modules are installed, power supply unit BSS-103A is required for AutroSafe 3 (see page 15) Integrated fire and gas detection systems 116-BSE-310 Input module BSE-320 Input module 8 0 Galvanically insulated inputs 116-BSJ-310 Output module 0 8 Open transistor outputs 116-BSS-310A Power supply module 116-BSS-311 Dual power monitoring module 116-BS-1342 Redundant power for I/O modules, kit 13

14 Communication Image Part number Description 116-BSD-321/1 AutroFieldBus protocol converter Interface between AutroFieldBus and AL_Com+. Enables communication between all AL_ Com+ modules in an AL_Com+ stack connected to AutroFieldBus. 116-BSL-310 AutroSafe communication module, serves as an interface for the common internal communication line between all the different I/O modules. Part of the fire alarm control panel. 116-BSL-321 Multi mode fibre optic converter Amplifier for AUTROLON/AutroFieldBus networks, which acts as a fibre optic modem. The converter ensures reliable communication for distances of up to 3000 m. Uses multi-mode (62.5/125 µm or 50/125 µm) fibre-optic cable. Degree of protection: IP BSL-322 Single mode fibre optic converter Amplifier for AUTROLON/AutroFieldBus networks, which acts as a fibre-optic modem. The converter ensures reliable communication for distances of up to m. Uses single-mode (9/125 µm) fibre-optic cable. Degree of protection: IP BSL-325 AUTROLON/AutroFieldBus communication amplifier Amplifier for communication signals on networks. The amplifier ensures reliable communication in systems where there is great distance between the system panels, and in applications where there are many panels. The amplifier increases maximum cable length from 1000 m to 2800 m. Degree of protection: IP BSL-330/1 116-BSL-330/2 116-BSL-330/3 116-BSL-330/4 MODBUS converter, slave, RS485 RS232/-422/-485 interface converter for use in communication between different programmable logic controllers and AutroSafe. For AutroSafe 3 only. MODBUS converter, master, RS485, ref. 116-BSL-330/1. For AutroSafe 3 only. MODBUS converter, slave, RS232, ref. 116-BSL-330/1. For AutroSafe 3 only. MODBUS converter, master, RS232, ref. 116-BSL-330/1. For AutroSafe 3 only. 116-BSL-336 Voyage data recorder interface Allows AutroSafe fire and gas detection systems data to be logged on voyage data recording systems. Converts standard AutroSafe AutroCom messages to NMEA-0183 standardscompliant strings, allowing events to be written to the VDR. Degree of protection: IP BSL-337 AutroSafe BU-70 interface module Enables the connection of BU-70/BU-100/BU-101 to AutroSafe. This is a simple, cost effective way to upgrade BS-100 systems to AutroSafe. Degree of protection: IP20 14

15 OPC server Part number 116-AS-OPC-SERVER/CD1 116-AS-OPC-SERVER/CD2 116-AS-OPC-SERVER/CD3 Description AutroSafe OPC server CD V1.0 incl. access code for access level 1. Includes read access to all status information for detectors, output and alarm devices. This level of license will also make it possible to send (write) Silence, Reset and SetTime commands to the AutroSafe system. Within this level you can also Disable/Enable detectors. AutroSafe OPC server CD V1.0 incl. access code for access level 2. Includes all functionality in level 1, plus the possibility to Activate/Deactivate and Enable/Disable outputs and alarm devices via OPC write commands. AutroSafe OPC server CD V1.0 incl. access code for access level 3. Includes all functionality in level 1 and 2. This level also provides additional information for points, for example AMEAS, Temp, Smoke, Alarm limits and Engineering values. Integrated fire and gas detection systems 15

16 Integrated fire and gas (IFG) modules Image Part number Description 116-BN-342/1 PowerLoop 4-20 ma input unit, rack mounted A general-purpose PowerLoop interface designed for third-party detectors connected to the AutroSafe IFG system. The unit has a 4-20 ma input galvanically isolated from the PowerLoop. 19 3U rack version, bare PCB with 19 rack front panel, no DC/DC. Degree of protection: IP BN-342/2 PowerLoop 4-20 ma input unit, DIN rail mounted A general-purpose PowerLoop interface designed for third party detectors connected to the AutroSafe IFG system. The unit has a 4-20 ma input galvanically isolated from the PowerLoop. DIN rail version, bare PCB in an open DIN rail box, no DC/DC. Degree of protection: IP BN-342/EX PowerLoop 4-20mA input unit, field mounted A general-purpose PowerLoop interface designed for third party detectors connected to the AutroSafe IFG system. The unit has a 24 VDC/400 ma supply output providing power to the connected detectors, plus a 4-20 ma input galvanically isolated from the PowerLoop. EEX me version including 9,5W 24 VDC/DC for external detector power supply. Degree of protection: IP BSD-340/1 PowerLoop driver module, rack mounted The module has a capacity of up to 15 detectors connected directly with protocol interface or through interface unit (BN-342/XX). The number of detectors must be verified by means of a PowerLoop calculator. Up to 31 BSD-340 units can be connected to one alarm panel through the AutroFieldBus driver (EAU-341). Degree of protection: IP BSD-340/2 PowerLoop driver module, DIN rail mounted The module has a capacity of up to 15 detectors connected directly with protocol interface or through interface unit (BN-342/XX). The number of detectors must be verified by means of a PowerLoop calculator. Up to 31 BSD-340 units can be connected to one alarm panel through the AutroFieldBus driver (EAU-341). Degree of protection: IP BSD-340/EX PowerLoop driver, for hazardous areas, zone 1 and 2, field mounted The module has a capacity of up to 15 detectors connected directly with protocol interface or through interface unit (BN-342/XX). The number of detectors must be verified by means of a PowerLoop calculator. Up to 31 BSD-340 units can be connected to one alarm panel through the AutroFieldBus driver (EAU-341). Degree of protection: IP66 16

17 Cabinets and racks Part number Description Dimensions H x W x D (mm) 116-SY-310 Battery cabinet for 12V / 27Ah batteries 350 x 347 x 193 a, b 116-UEA-323/1 Empty cabinet for BS-310/320/BC-320/SY x 320 x BT-323/1 Termination cabinet with AutroSafe 3 front 350 x 347 x 193 a, b 116-BT-323/2 Termination cabinet with AutroSafe 3 front and power supply BSS-103A 350 x 347 x 193 a, b 116-UEN024/63-1 AutroSafe 4 cabinet with door frame for wall mounting 700 x 600 x UEN024/64-1 AutroSafe 4 cabinet with door frame for wall mounting 1200 x 600 x UEN024/65-1 AutroSafe 4 cabinet with door frame for wall mounting 1800 x 600 x 400 Notes Side walls and base not included a: Includes battery cable, termination block and fuses. Accommodates 2x12V / 27Ah sealed batteries. Charger is not included. b: Can be used for both AutroSafe systems. Mounting accessories for cabinets and racks Module height unit = 44.5 mm. Width unless specified otherwise = 48.3 mm. Integrated fire and gas detection systems Part number Description Dimensions (mm) 116-UW-1454 Mounting kit for 19 cabinet/rack. Front panel. h = Height units Notes For BS-310/-320/-330/ and BC UW-1459/1 Mounting kit for 19 cabinet/rack. Complete cabinet. h = For BS-310/-320 and BC UW-1482 Mounting kit for 19 cabinet/rack. Front panel h = For BU-/BV-320 and BU-BV UW-1514 Front panel for 19 cabinet/rack h = For BS-420/-430 and BC UW-1518 Mounting plate h x w = 622 x 455 For mounting AutroSafe 4 front panel on double BS-100 cabinet 116-UE-1662 Spacer (between 2 rack mounted panels) h x w = 80 x UB rack mount kit for BSD-341/1 and BSD-342/1 h = 160 Accomodates up to 4 BSD units 116-UW-414 Rittal cover plate for 19 rack, 3 mm anodized aluminium h = UW-1483/1 Front plate for 19 rack, 2 mm black zintec plate h = UW-1483/2 Front plate for 19 rack, 2 mm black zintec plate h = UW-1483/3 Front plate for 19 rack, 2 mm black zintec plate h = UW-1483/4 Front plate for 19 rack, 2 mm black zintec plate h = UW-1483/5 Front plate for 19 rack, 2 mm black zintec plate h = UW-1484/1 Front plate for 19 rack, 2 mm black zintec plate h = UW-1484/2 Front plate for 19 rack, 2 mm black zintec plate h = UW-1484/3 Front plate for 19 rack, 2 mm black zintec plate h = UW-1484/4 Front plate for 19 rack, 2 mm black zintec plate h = UW-1484/5 Front plate for 19 rack, 2 mm black zintec plate h = Rittal cabinets or equivalent are available on request. 17

18 Batteries offers accumulator batteries for every Autronica fire alarm system. Generally, 24VDC back-up is used, this requires two batteries per panel. All batteries are sealed and can be placed in cabinets. Dimensions Part number Description Voltage Weight LxWxH FIAMM FG V / 7.2 Ah 2,4 kg 79 x 56 x 106 mm FIAMM FG V / 18 Ah 5,9 kg 181 x 76 x 167 mm FIAMM FG V / 27 Ah 8,7 kg 166 x 175 x 125 mm FIAMM FG V / 42 Ah 13,8 kg 196 x 163 x 174 mm FIAMM FG V / 12 Ah 4,0 kg 151 x 98 x 99 mm FIAMM FG V / 70 Ah 22,7 kg 350 x 166 x 174 mm Sonnenschein A512/ V / 115 Ah 40,0 kg 286 x 269 x 230 mm Sonnenschein A512/85 12 V / 80 Ah 31,0 kg 330 x 171 x 236 mm Sonnenschein A115/ V / 200 Ah 70,0 kg 518 x 274 x 242 mm Power supply units Part number Description Output voltage 116-BPS-405 Power supply unit for AutroSafe 4 24 VDC / 5 A 116-BPS-410 Power supply unit for AutroSafe 4 24 VDC / 10 A 116-BPS-410/115 Power supply unit for AutroSafe 4, 115 VAC 24 VDC / 10 A 116-BSS-103A Power supply for AutroSafe 3, including cover 27,3 VDC / 3 A 116-BSS-103A/ Power supply, without cover, with NTC resistor. Temperature compensated battery charging Power supply for AutroSafe, for additional power. Temperature compensated battery charging 27,3 VDC / 3 A 27,3 VDC / 10 A DC/DC converter MINI-PS DC / 24 DC1 24 VDC / 1 A DC/DC converter 24 VDC / 6,3 A 18

19 Cables Part number 116-XJA XJA XJA XJA XGE-1/10-XX 116-XGK-1/10-XX 116-XGE-1/14-XX 116-XGK-1/ Relays Description Connection cable for AS 2000; for connection between PC and fire alarm panel (AS SYSUTILPAC includes this item) Connection cable for AS LoopSim, for PC panel interconnection Connection cable for AS Download, for PC panel interconnection Connection cable for EAU-321, for PC module interconnection Ribbon cable. Optional lengths: 7, 40 or 110 cm. Replace XX with length Ribbon cable. Optional lengths: 40, 100 or 150 cm. Replace XX with length Ribbon cable. Optional lengths: 7, 30, 40, 90 or 200 cm. Replace XX with length Ribbon cable. Length: 140 cm Integrated fire and gas detection systems Part number Description Relay PLC RSC 24 DC/21, single change-over contact Relay PLC RSC 24 DC/21-21, double change-over contact Customer configuration Part number 116-PROG-AUTROSAFE 116-TXT-AUTROSAFE Description Customer specific software for AutroSafe Customer texts/controls 19

20 AutroMaster a fully integrated safety and emergency management system The AutroMaster is an integrated safety and emergency management system combining the strengths of a powerful fire detection system with control and monitoring functions dedicated to make sure you are in control in case of an emergency. Graphical user interface The AutroMaster provides an intuitive control and monitoring interface built to save valuable time when every second counts. Status information is displayed in real-time with easy-to-understand graphical representation. Navigation is fast and instinctual and the powerful zoom functions allow you to monitor all areas in great detail. AutroMaster displays values for smoke density and heat in dynamic colours, making it easy to perform the necessary actions during emergencies. Interoperability Control and monitoring of third party systems can easily be performed via serial protocols or network interfaces. They provide connection to basically any source network time servers, telephone systems for text messaging, public address systems for automated voice messaging, emergency lights, access control systems, CCTV, automation systems and so on. Logging and reporting The AutroMaster keeps track of all events in the system and has a built-in report generator. This provides a cost-effective system log for maintenance and documentation purposes. Decision-making tools In high-risk environments around the world, a seemingly innocuous fire can quickly escalate into an emergency of large proportions. When disaster strikes and you only have seconds to make the proper decisions, the right safety and emergency management system is an invaluable asset. The AutroMaster includes a Decision Support System (DSS) that will help you make the right decisions at the right time. Easy to use, provides full overview and saves valuable time 20

21 AutroMaster editions AutroMaster ISEMS is the complete AutroMaster edition, including all functionality. In addition, we offer a market specific edition with the modules most relevant for the oil and gas market AutroMaster Modules/functions Basic functionality Fire management basic functions MultiSensor control Report generator Control and monitoring of emergency lights/lll Extended functionality AutroSafe IFG unit support Touch screen support Decision support system/incident manager Electronic plotting table Training/simulation module Event record and replay module Video module (live video support CCTV) Remote connect function Message center module Interfaces Hernis CCTV interface System-S interface NMEA interface Saia PLC support VDR output Siemens S7 PLC support MODBUS interface ESPA interface 21

22 Software licences Part number 116-PROG-AUTROMASTER-POG 116-PROG-AUTROMASTERISEMS 116-PROG-AM-UPGRADE Description AutroMaster Oil & Gas Edition For the Petrochemical, Oil and Gas market applications, support for the SIL2 approved AutroSafe IFG panel is mandatory. The AutroMaster Oil & Gas Edition is specially designed to use the AutroSafe IFG functionality to among other functions provide gas trending and LEL indication. AutroMaster ISEMS Provides the full range of functionality every possible add-on module is included in this package, making it the perfect choice for demanding applications and professional customers. Upgrade of AutroMaster to most recent version Existing AutroMaster customers can upgrade their license to the most recent version of AutroMaster. Requires change of AutroMaster configuration data. Software modules Part number 116-PROG-AM-MOD-DSS Description Decision Support System (DSS) An interactive incident management system for AutroMaster. The DSS gives operators access to customer-specified checklists. The checklists are organized as checkpoints with one or more action items that can be used to manage operations, and these can be marked off as actions are completed. 116-PROG-AM-MOD-EPTABLE Electronic fire control plotting table gives you a dynamic plotting table to keep track of actors events during an emergency or drill. All EPT activity is logged in the Decision Support System and is available for later reviews. 116-PROG-AM-MOD-TSIM Training/Simulation module A tool to simulate pre-configured events. During a simulation it is possible to pause, stop/end, and continue the simulation. Running the simulation tool is similar to running a live event, alarms and faults are acknowledgeable and resettable. Every event is logged, and after a simulation (or a stop), a full log can created and it is possible to replay the simulation using the Event record/replay module. 116-PROG-AM-MOD-EVENT 116-PROG-AM-MOD-VIDEO 116-PROG-AM-MOD-REMOTE 116-PROG-AM-MOD-MC Event Record/Replay module Offers a screenshot-based replay of incidents on AutroMaster and can be configured to start recording manually or on pre-configured events as pre-warning, alarm or simulation. Recordings are available for replay, and under replay the operator can start, stop, pause, fast-forward and fast backwards. It is possible to export stored events. Video interface module Includes display of live video in AutroMaster from IP based video cameras. Remote Connect function The Remote Connect Module enables a remote connection to AutroMaster from any location using a server/client technology. Message Centre module In the Message Centre the user can send text messages to telephone systems and other AutroMaster PCs. The user can also send pre-recorded voice messages to PA systems. Requires ESPA interface. 22

23 Interface modules Part number 116-PROG-AM-MOD-HERNIS Description Hernis CCTV interface Interface enables use of AutroMaster together with video cameras and servers from Hernis. AutroMaster 116-PROG-AM-MOD-NMEA NMEA interface A protocol used for interface in between maritime electronic equipment, and AutroMaster has built-in support for this in the NMEA interface module. Interface towards GPS is the most common application. 116-PROG-AM-MOD-SAIAPLC Saia PLC support With the Saia PLC support, the AutroMaster can interface towards PLCs using Saia as protocol. 116-PROG-AM-MOD-VDROUTPUT VDR output Used in maritime applications for giving output to the Voyage Data Recorder. Configuration of which data and status messages to send to the VDR is done by project engineering. 116-PROG-AM-MOD-S7PLC Siemens S7 PLC support With the Siemens S7 PLC support, the AutroMaster can interface towards PLCs using S7 as protocol. 116-PROG-AM-MOD-MODBUS MODBUS interface With the MODBUS interface AutroMaster can be connected to almost any kind of electronic equipment for monitoring and control. 116-PROG-AM-MOD-ESPA444 ESPA interface Offers a serial protocol intended for the interconnection of paging equipment with telephone exchanges or computer systems. The protocol used is message-based and is built upon the ISO1745 transport specification. Required if Message Centre module is used. Software hardcopies Part number 116-PROG-AUTROMASTER-CD Description CD containing AutroMaster software required for installation Engineering Part number 116-PROSJAMD 116-PROSJAMDF Description Adding of detectors to drawings Adding of color fill for analog values 23

24 Hardware Part number 116-AUTROMASTER-PC AUTROMASTER-RACKPC Description PC, desktop version, convertible minitower 19" rack mounted PC " standard LCD monitor (1280x1024 resolution) " widescreen LCD monitor (1920x1200 resolution) monitor, console mounted, JH20T17 MMD Keyboard - UK/English character set Mouse - USB - 3 buttons PC loudspeakers for desktop use PC loudspeakers for internal mounting (in 5.25" bay on PC) Laser printer, colour, network and USB USB printer cable, 3 meters Com switch 5 sp 10/ Cat5 patch cable 5 meters, straight Cat5 patch cable 5 meters, crossed 24

25 25 AutroMaster

26 Loop units a wide range covering your basic fire detection needs We provide a wide range of loop units for our fire detection systems. Our detectors, manual call points, I/O units, control units and alarm units are developed and approved according to European directives (CPD) requiring EN 54 compliance and other appropriate worldwide regulations. The loop units are available both with and without SelfVerify function. SelfVerify solves all issues of manual maintenance, leaving time consuming and costly physical testing no longer necessary. With AutroSafe SelfVerify, the system checks all detectors, interfaces, connections and cables from detector chamber to alarm output every single day. Not only does the system test whether a detector is capable of provoking an alarm, it even verifies the sensitivity of every detector with a calibrated signal. The SelfVerify system ensures that each detector always responds to the correct alarm level. In the event of irregularities, the display on the operating panel will accurately pinpoint the source of any problem. SelfVerify ensures that you have the safest and most reliable fire safety system available a system ensuring optimal detection. 26

27 Input and output units AutroSafe offers a wide range of input and output units for many different applications. The system features Exn-, Exia- and Exd approved input and output units for high risk applications. All input and output units feature automatic addressing and short-circuit protection. Image Part number Description Configurable input Monitored input Monitored output Inputs/outputs Requires external PSU SelfVerify For use in EX areas Degree of protection* Notes Loop units 116-BN-180 AutroKeeper IP30 Use two units to access one loop from two loop controllers. DIN rail mounting in cabinet. 116-BN-201 Monitoring unit 1/0 IP54 IP67 For external units 116-BN-221/01 Extinguishing control unit 2/1 IP BN-221/02 Output unit with 7A relay 0/1 IP67 Loop controlled FAD unit 116-BN-300 Input unit 1/0 IP54 IP67 For interfacing external units, clean contacts, alarm relays, etc. 116-BN-300M Modular input unit 1/0 Mounting on TS-35 rail *: When two degrees of protection is given, the lowest is relevant when using membrane inlets and the highest when using PG inlets 27

28 Input and output units (cont.) Image Part number Description Configurable input Monitored input Monitored output Inputs/outputs Requires external PSU SelfVerify For use in EX areas Degree of protection* Notes 116-BN-303 Single monitored input unit 1/0 IP54 IP67 Function selectable via dip switch 116-BN-304 Input/output unit 1/1 IP54 IP67 Function selectable via dip switch 116-BN-305 Dual monitored input/ output unit 2/2 IP54 IP67 Function selectable via dip switch Will be released by bulletin 116-BN-307 Monitored FAD control unit 1/1 IP54 IP67 Will be released by bulletin 116-BN-310 Relay output unit 0/1 IP54 IP67 *: When two degrees of protection is given, the lowest is relevant when using membrane inlets and the highest when using PG inlets 28

29 Input and output units (cont.) Image Part number Description Configurable input Monitored input Monitored output Inputs/outputs Requires external PSU SelfVerify For use in EX areas Degree of protection* Notes Loop units 116-BN-320 Interface unit 2/1 IP54 IP67 For AutroFlame/AutroBeam 25/ AutroSense BN-320/2 Door control unit 2/1 IP54 IP BN-320/4 Standard control unit 2/1 IP54 IP67 Control of external equipment 116-BN-320/5 Sprinkler monitoring unit 1/0 IP54 IP BNB-331 Loop adapter unit for conventional loops 1/1 IP20 *: When two degrees of protection is given, the lowest is relevant when using membrane inlets and the highest when using PG inlets 29

30 Input and output units (cont.) Image Part number Description Configurable input Monitored input Monitored output Inputs/outputs Requires external PSU SelfVerify For use in EX areas Degree of protection* Notes 116-BN-500/EX Input unit 1/0 IP54 IP67 For interfacing external units, clean contacts, alarm relays, etc. Zones 0, 1 & BN-500/N Input unit 1/0 IP54 IP67 For interfacing external units, clean contacts, alarm relays, etc. Zone BN-505/EXD Input unit with BNB /0 IP66 Zones 1 & 2 only *: When two degrees of protection is given, the lowest is relevant when using membrane inlets and the highest when using PG inlets 30

31 Control units AutroSafe offers control units for enabling and disabling of detectors, as well as daytime/nighttime units. Available in several language versions. Replace XX with country code. Loop units Image Part number Description For AutroSafe only Configurable delay For external control Number of buttons Degree of protection Notes 116-BW-200/XX Disablement unit 2 IP66 Available in Swedish, English and Russian 116-BW-201/XX Disablement unit 0 IP66 Available in Swedish and English 116-BW-202/XX Daytime/Nighttime unit 2 IP66 Up to two units can be powered from detector loop. To connect more units, external 24VDC power is required. Available in English only. 116-BW-203/XX Daytime/Nighttime unit 0 IP66 Up to two units can be powered from detector loop. To connect more units, external 24VDC power is required. Available in English only. 116-BU-200 Alarm controller unit 2 IP66 31

32 Detectors AutroSafe offers a wide range of detectors for many different applications, with or without SelfVerify. The following series are available: n 200 series, standard interactive addressable detectors n 300 series with SelfVerify, interactive addressable detectors n 500 series with SelfVerify, interactive addressable detectors for use in hazardous areas The system also offers Exn- and Exia approved versions of detectors designed for use in high risk applications. S series smoke detectors are specially designed for applications where high sensitivity is required. Image Part number Degree of protection SIL 2 compatible Wet/dry areas Sealed unit High sensitivity For use in EX zone 2 only For use in EX areas Environmentally protected Including base SelfVerify MultiSensor Smoke Heat 116-BD-200M W IP BD-501 W IP BD-501/EX W IP BD-501/N W IP56 Notes For galleys/cold areas (-30 ºC) 116-BD-55/XXXEXD IP66/67 * Conventional 116-BD-55/XXXEXDN IP66/67 ** Conventional 116-BD-505/140EXD W IP BD-505/160EXD W IP BD-505/190EXD W IP66 60 ºC, non-configurable class, explosion proof 70 ºC, non-configurable class, explosion proof 90 ºC, non-configurable class, explosion proof *: Available with the following alarm temperatures (replace XXX with F): 140 F (60 C), 160 F (70 C), 190 F (90 C), 225 F (110 C), 325 F (165 C), 360 F (180 C), and 450 F (230 C) **: Available with the following alarm temperatures (replace XXX with F): 225 F (110 C), 275 F (135 C), 325 F (165 C), 360 F (180 C), and 450 F (230 C) 32

33 Detectors (cont.) Image Part number Degree of protection SIL 2 compatible Wet/dry areas Sealed unit High sensitivity For use in EX zone 2 only For use in EX areas Environmentally protected Including base SelfVerify MultiSensor Smoke Heat 116-BDH-300 D IP44D 116-BDH-500 IP44D Notes Loop units 116-BDH-500/EX IP44D 116-BDH-500/N IP44D 116-BHH-300 IP44D 116-BHH-500 IP44D 116-BHH-500/EX IP44D 116-BHH-500/N IP44D 116-BHH-500/S IP44D 116-BHH-500/S/EX IP44D 116-BHH-500/S/N IP44D 116-BHH-320 IP44D 116-BHH-520 IP44D 116-BHH-520/EX IP44D 116-BHH-520/N IP44D W IP54 Thermostat ATHF-SE-2, C For use in Safe Area or Ex zone 2 Suitable for use in sauna W/ D IP65 SWM-1KL 140 C 33

34 Manual call points and release stations AutroSafe offers a wide range of manual call points for different applications, every unit features SelfVerify. Two main series are available: n 300 series with SelfVerify, interactive addressable manual call points. n 500 series with SelfVerify, interactive addressable manual call points for use in special environments. The system features Exn- and Exia approved versions for high risk applications. All our manual call points can be delivered with a double-action cover. Image Part number Description For use in EX areas For use in EX zone 2 only Watertight / outdoor model Extreme environments LED indicator Metal connection box Glass not included Glass-free Duty label, ref. E-2327 Degree of protection* 116-BF-300V2 Manual call point IP42D* 116-BF-510WP-H Manual call point IP52* 116-BF-300M/N Manual call point IP44D* 116-BF-500V2/EX Manual call point IP44D* 116-BF-500/N Manual call point IP44D* *: Degree of protection, inner housing 34

35 Manual call points and release stations (cont.) Image Part number Description For use in EX zone 2 only For use in EX areas Watertight / outdoor model Extreme environments LED indicator Metal connection box Glass not included Glass-free Duty label, ref. E-2327 Degree of protection Loop units 116-BF-501 Manual call point IP BF-501/EX Manual call point IP BF-501/N Manual call point IP BF-502 Manual call point IP BF-502/EX Manual call point IP BF-502/N Manual call point IP BF-503/0100 Manual call point IP BF-503/EX/0100 Manual call point IP BF-503/N/0100 Manual call point IP BF-503/EX/0200 CO2 release station IP BF-503/N/0200 CO2 release station IP KIT-BF-503/EX/0300 Release station IP KIT-BF-503/N/0300 Release station IP KIT-BF-503/EX/0400 Release station IP KIT-BF-503/N/0400 Release station IP66 35

36 Manual call points and release stations (cont.) Image Part number Description For use in EX areas For use in EX zone 2 only Watertight / outdoor model Extreme environments LED indicator Metal connection box Glass not included Glass-free Duty label, ref. E-2327 Degree of protection 116-BF-503/0500 Release station IP KIT-BF-503/EX/0500 Release station IP KIT-BF-503/N/0500 Release station IP BFG-3/XX Glass for call point, available in several languages. Replace XX with country code. *XX replacements: No ending = No text D = German E = Spanish EW = Estonian F = French GB = English GB/AR = English and Arabic GB/D = English and German GB/F = English and French GB/P = English and Portugese GB/PL =English and Polish H = Hungarian I = Italian IS = Islandic J = Japanese N/GB = Norwegian and English NL = Dutch P = Polish RC/GB = Chinese and English S = Swedish SF = Finnish SU = Russian SU/GB = Russian and English MEDC manual call points and release stations distribute MEDC equipment. Please contact us with your request. These products are produced according to customer specifications. 36

37 Alarm units AutroSafe offers a wide range of alarm units for connection to detection loops or dedicated alarm outputs. Image Part number Description Degree of protection dba/1m Light Sound Watertight Configurable Signal presets Electronic Alarm output mounted Loop mounted/adressable Notes Loop units 116-BBL-100 Beacon Supported only by AutroSafe version 4.3 or later 116-BBL-100/IP Beacon Supported only by AutroSafe version 4.3 or later 116-BBR-7M Alarm bell 6 93 IP BBR-110 Base sounder* 86 IP42 Combined detector base and addressable sounder. 116-BBR-130 Base sounder 90 IP32C Combined detector base and addressable sounder. Supported only by AutroSafe version 4.3 or later *: If loop driver BSD-311 is used, max. no. of units per loop is 40 If loop driver BSD-310 is used, max. no. of units per loop is 21 37

38 Alarm units (cont.) Image Part number Description Light Sound Watertight Configurable Signal presets Electronic Alarm output mounted Loop mounted/adressable dba/1m Degree of protection Notes 116-BBR-200 Sounder 100 IP BBR-200/IP Sounder 100 IP BBR-200/W Sounder 100 IP BBR-230 Sounder 100 IP32C Supported only by AutroSafe version 4.3 or later 116-BBR-230/IP Sounder 100 IP65 Supported only by AutroSafe version 4.3 or later 116-BBQ-130 Base sounder w/ beacon 90 IP21C Combined detector base and addressable sounder/beacon. Supported only by AutroSafe version 4.3 or later 38

39 Alarm units (cont.) Image Part number Description Light Sound Watertight Configurable Signal presets Electronic Alarm output mounted Loop mounted/adressable dba/1m Degree of protection Notes Loop units 116-BBQ-230 Sounder/beacon 100 IP32C Supported only by AutroSafe version 4.3 or later 116-BBQ-230/IP Sounder/beacon 100 IP65 Supported only by AutroSafe version 4.3 or later Roshni LP, shallow base IP Roshni LP, shallow base 102 IP Roshni, deep base 102 IP Flashni, shallow base 101 IP54 39

40 Alarm units (cont.) Image Part number Description Light Sound Watertight Configurable Signal presets Electronic Alarm output mounted Loop mounted/adressable dba/1m Degree of protection Notes Flashni, deep base 101 IP Sounder 110 IP66 /67 48 VDC ATEX approval Ex II 2GD EExd IIC T Hella rotating beacon IP55 24 VDC Hella rotating beacon IP VAC Xenon beacon Solex beacon, shallow base IP54 40

41 Alarm units (cont.) Image Part number Description Light Sound Watertight Configurable Signal presets Electronic Alarm output mounted Loop mounted/adressable dba/1m Degree of protection Notes Loop units Solex beacon, deep base IP Solex beacon, shallow base IP54 MEDC beacons, sounders, and combination units distribute MEDC equipment. Please contact us with your request. These products are produced according to customer specifications. 41

42 Door magnet Image Part number Description Door magnet armature. Type AG w/adjustable socket. For use with part no: Door holding magnet. GPT, holdpower 650 N, 1 W, 40 ma. Manual release push button. DNV approved. For use with part no: Accessories for loop units Suitable for EX Part number Description installations 116-BWA-100 Base for interactive detector heads, mandatory 116-BWB BU-46 Base adapter for analogue addressable detectors mounted on interactive loop Alarm indicator for smoke and heat detectors 116-BWP-100/20 Drip proof conduit box with M20 glands 116-BWP-100/25 Drip proof conduit box with holes for M25 glands 116-BWP-143/150 Ventilation duct adapter 150 mm 116-BWP-143/300 Ventilation duct adapter 300 mm 116-BWP-143/550 Ventilation duct adapter 550 mm 116-BWP-145 Heated detector base Transformer 230/48 V for up to 10 BWP-45/BWP WBW-100 Bypass unit for BWA WBW-101 Mounting plate for false ceilings 116-BZ BZ-500/01 Galvanic barrier for Exia approved detectors, for field mounting Galvanic barrier for Exia approved detectors, for cabinet mounting Lift flap in polycarbonate for manual call point 116-BF-502, all versions Lift flap in stainless steel for manual call point 116-BF-502, all versions Lift flap in polycarbonate for manual call point 116-BF-501, all versions Lift flap in stainless steel for manual call point 116-BF-501, all versions Power base 230 V for Roshni alarm unit 42

43 Service tools for detection loops Part number Description 116-WAS-2000 AS2000, loop diagnostics hardware Suitable for EX installations Loop units 116-SW LV AS-MODBUSCD 116-AS-MODBUSSERVPK AS2000, loop diagnostics software AutroSafe loop viewer, a simplified version of AS2000 MODBUS converter service CD, latest version, for use with BSL-330 module MODBUS converter service pack, CD and cables, for use with BSL-330 module 116-WBJ-5/01 Test gas dispenser for smoke detectors, excluding pole 116-WBJ-5/02 Telescopic pole, 1,26 m to 4,5 m, 1,8 kg 116-WBJ-5/03 Expansion pole, 1,13 m. 0,5 kg 116-WBJ-5/04 Test gas for smoke detectors 116-WBJ-6/ WBJ-10 Heat detector test kit, battery operated, 2 x batteries and charger included (for WBJ- 5/02) Testifire smoke/heat detector test kit (head unit 2 x battery baton and fast charger) 116-WBJ-10/ WBJ-10/ WBJ-10/ WBJ-10/04 Testifire smoke/heat head unit Smoke capsule for WBJ-10 (6 pack) Solo 760 battery baton Solo 725 universal fast battery charger 116-WBJ-140 Installation/extraction tool for AutroSafe detectors 43

44 Flame detection keeping a close watch Autronica s flame detectors are solutions for applications in which risk to personnel is high and where fire might result in a large loss of equipment. Beyond critical life-safety concerns, our products have proven to minimize total cost of ownership while minimizing false alarms. Our industrial and commercial applications include oil and gas pipelines, turbine enclosures, offshore platforms, and Floating Production Storage and Offloading (FPSO) vessels. Bottom line no other company offers more flame-detection technologies with wider area coverage, higher false-alarm immunity, reduced response times, and the appropriate global approvals. And to improve ease of use, all X-Series flame detectors have HART-protocol options. 44

45 Flame detectors All flame detectors have 4xM25 cable entries, unless otherwise specified. Swivel mount, glands and blind plugs are not included. All detectors have an ambient temperature range of -55 C to + 60 C for T6 and -55 C to + 75 C for T5, unless otherwise specified. Degree of protection all detectors and cameras: IP66 Image Part number Description Stainless steel housing Aluminium housing Addressable (built-in BNB-300) Combination unit with camera av. For PowerLoop Cert. -55 C to +125 C for T4 With HART protocol SIL 2 approved Notes Flame detectors AutroFlame X22 UV AutroFlame X22 UV AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR Low sense AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR High sense AutroFlame X33AF multisp. IR Low sense AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR 45

46 Flame detectors (cont.) Image Part number Description AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR Stainless steel housing Aluminium housing Addressable (built-in BNB-300) Combination unit with camera av. For PowerLoop Cert. -55 C to +125 C for T4 With HART protocol SIL 2 approved Notes UL Brazil approved 3/4 NPT AutroFlame X33AF PL multisp. IR AutroFlame X33AF PL multisp. IR AutroFlame X33AF PL multisp. IR AutroFlame X33AF PL multisp. IR Low sense Low sense AutroFlame X33AF multisp. IR AutroFlame X33AF multisp. IR AutroFlame X3302 multisp. IR Hydrogen flame detection AutroFlame X52 UV/IR AutroFlame X52 UV/IR AutroFlame X52 UV/IR UL Brazil approved 3/4 NPT 46

47 Flame detectors (cont.) Image Part number Description With HART protocol Cert. -55 C to +125 C for T4 For PowerLoop Combination unit with camera av. Addressable (built-in BNB-300) Aluminium housing Stainless steel housing Notes Flame detectors AutroFlame X98 single IR AutroFlame X98 single IR xwatch surveillance camera * xwatch surveillance camera * *: For use with any AutroFlame flame detector. M20, PAL video output. For use in EX areas. FM/CSA approved. 768 x 484 pixels camera, 90º optical lens (other lenses available). 47

48 Accessories Part number Description Cable gland M25, polyamid, Eexe, degree of protection: IP Blind plug M25, polyamid, Eexe, degree of protection: IP Cable gland adapter M20/M Blind plug M20, brass, nickel plated. Exd/Exe, degree of protection: IP66/ Blind plug M25, brass, nickel plated. Exd/Exe, degree of protection: IP66/ K1003A1006 Window cleaner for flame detectors (6 pcs.) Q9001H8001 swivel for xwatch camera SS Q9001B1175 swivel for xwatch camera alu Q9033B Swivel mount for AutroFlame detectors, stainless steel Q9033A Swivel mount for AutroFlame detectors, aluminium Q2033A10R 10 degree field-of-view limiter Q2033A20R 20 degree field-of-view limiter Q2033A30R 30 degree field-of-view limiter/weather shield (maintains standard field-of-view) Q1116A air shield assembly Q1198A dual air shield/flange mount assembly Test equipment Part number Description W8067S Long range test lamp IR/UVIR, (non-ex) W867C Portable test lamp 220 V, UV, UV/IR & Single IR Q1201C Laser holder for AutroFlame X33AF, UV/IR and UV flame detectors Laser aimer (non-ex) for AutroFlame detectors incl. battery Charger and battery, for test lamp W6300B Inspector connector for connection to PC utilizing an integral RS485 to RS232 converter for communication Inspector monitor software. To be used together with inspector connector O/I replacement kit for AutroFlame X33AF with black reflector plate* O/I replacement kit for AutroFlame X33AF with stainless steel reflector plate* O/I replacement kit for AutroFlame X22, X52 and X Test magnet for AutroFlame X33AF Test magnet and extension pole *Please note: AutroFlame X33 models are supplied with either a black or a stainless steel reflector plate. These plates are not interchangeable. Order the replacement that matches the reflector plate on your AutroFlame X33 detector. 48

49 49 Flame detectors

50 Gas detection when every second counts When it comes to detecting toxic gas would you rather be alerted in 30 seconds... or 5 seconds? In the demanding environments of the petrochemical oil and gas industry, fire and gas detection has to deliver optimal results at all times. Autronica offers traditional detectors with 4-20mA and/or relay output, but we have also taken the IR point gas detection a step further. By introducing the two wire intelligent communication on our IFG PowerLoop we allow for centralized control of all diagnostic data. Analogue readings and detector self testing features are available from our AutroPoint IR gas detectors. The open path IR gas sensing technology surpasses other alternatives, both with respect to the life cycle cost as well as operational tangibles of a more technical nature. Our AutroPath HC600 open path infrared beam system delivers reliable, combustible gas monitoring for all types of applications. With our new AutroTox toxic gas detector family, you get a gas detector that continuously monitors the atmosphere for potentially hazardous gas leaks and oxygen depletion. An array of sensor models detect a variety of gases in various concentration ranges. Autronica delivers the performance, quality, and reliability you can depend on to keep you safe and satisfied. 50

51 Gas detectors Image Part number Description Cable entries HART protocol included With relay output With hydrophobic filter* Stainless steel housing Catalytic combustible Electrochemical Infrared hydrocarbon AutroPoint HC200 2xM25 Notes Gas detectors AutroPoint HC200 2xM AutroPoint HC200 2x3/4" NPT AutroPoint HC200 2xM AutroPoint HC200 2xM25 Cepel approved AutroPoint HC300PL 2xM25 Addressable, PowerLoop version AutroPoint HC300PL 2xM25 Addressable, PowerLoop version 116-GD10-P00-17DG-0XH-00 GD-10P 2xM20 5 sec. response 116-GD10-P00-17DG-0XH-01 GD-10P 2xM20 1 sec. response AutroPath HC600 2xM Z-02104N4011 Searchline Excel IR gas detector 116-Z-OBSERVER Observer acoustic gas detector 2xM20 x 1,5 *: Recommended for areas with high levels of airborne particulates or humidity. Other detectors available on request. 51

52 Toxic gas detectors Autronica provides toxic gas detectors for a wide range of gases. These detectors must be combined with a toxic gas sensor module, listed below. The detectors each have a 4-20 ma output and 2 x M25 cable entries. HART protocol is included. Image Part number Description AutroTox GTD w/autrovu AV10 display unit Eex ia certified Eex d certified RS485 output With relay output Aluminium housing Stainless steel housing NTMOS Electrochemical Notes AutroTox GTD w/autrovu AV10 display unit AutroTox GTD w/autrovu AV20 display unit AutroTox GTD w/autrovu AV20 display unit Toxic gas sensor modules Image Part number Description Range GTS H 2 S 20P 0 20 ppm GTS H 2 S 50P 0 50 ppm GTS H 2 S 100P ppm GTS Cl 2 10P 0 10 ppm GTS NH 3 500P ppm GTS H P ppm GTS O 2 25V 0 25 % by volume GTS CO 100P ppm GTS CO 500P ppm GTS SO 2 20P 0 20 ppm GTS SO 2 100P ppm INMETRO approved versions available 52

53 Toxic gas transmitters and termination boxes Image Part number Description Eex d certified Stainless steel housing NTMOS Electrochemical Notes Gas detectors GTX Transmitter STB Termination Box NTM1B10W NTMOS H2S Sensor (0-100 ppm) GDTB Termination Box Q912 Duct Mount Kit with transmitter Please specify length of inlet tube at time of order (1, 3, 6, or 10 ft.) 53

54 Display units All display units have 4-20 ma output and HART protocol included Image Part number Description Eex ia Eex d Relay output RS485 output Aluminium housing Stainless steel housing Catalytic combustible NTMOS Electrochemical Cable entries Notes AutroVu AV10 5xM AutroVu AV10 5xM AutroVu AV10 3/4 NPT INMETRO (Brazil) AutroVu AV10 3/4 NPT INMETRO (Brazil) AutroVu AV10 5xM AutroVu AV10 5xM AutroVu AV10 CGS 5xM AutroVu AV20 5xM AutroVu AV20 5xM25 Test equipment all gas detectors Part number Description Remote HART port kit, incl. 20 m prefab cable set Cordset, 20 meters intrinsically safe cable with prefab connectors SS adapter for AutroPoint HC200/-300 HART connector HART port connector box, IP Z-475HP1EKL9GMT Emerson 475 HART communicator. Instrument for calibration of AutroPoint HC200 and AutroPath HC600 gas detectors. Certified intrinsically safe by CENELEC/ATEX, FM, CSA, FISCO and IECEx 54

55 Accessories Part number Description Duct mount kit for point gas detector AutroPoint TX Duct mount assembly for point gas detectors AutroPoint HC200 and HC300PL. One duct air inlet tube and one return tube. Pipe length to be specified: 1ft/305mm ( ), 3ft/915mm ( ), 6ft/1830mm ( ) or 10ft/3050mm ( ) Direct duct mount kit for point gas detectors AutroPoint HC200 and HC300PL Gas detectors System test film LFL - Low alarm System test film LFL - High alarm Aperture kit for HC600, SS, for distances of 5 to 30 meters Aperture kit for HC600, plastic, for distances of 5 to 30 meters Alignment telescope for AutroPath HC Toxic sensor termination box and separation kit. JBOX, SEP, AL, M20 CENELEC toxic Toxic sensor termination box and separation kit. JBOX, SEP, AL, M25 CENELEC Infinity Blind plug M25, polyamid, Eexe, degree of protection: IP Cable gland M25, polyamid, Eexe, degree of protection: IP US Z-GD10-ADAPT1 116-Z-ES-244 Rain and sun shield for point gas detectors AutroPoint HC200 and HC300PL Duct adapter for point gas detector GD-10P Gas detector test point Cable glands/blind plugs Part number Description /453/UNIV/B M25 nickle plated brass /421/B M25 EEXE nickle plated brass /453/UNIV/OS-M20 nickle plated brass /453/UNIV/O-M20 nickle plated brass /453/UNIV/A-M20 nickle plated brass /421/Os M20 EEXE nickle plated brass /421/O M20 EEXE nickle plated brass /421/A M20 EEXE nickle plated brass EEXDE adapter M25-20 nickle plated brass SPMH/NP/M20 blind plug nickle plated brass SPMH/NP/M25 blind plug nickle plated brass 55

56 Calibration kits Part number Gas type Concentration Notes Methane CH 4 50 % LEL AutroPoint HC200/ Hydrogen Sulphide H 2 S 50 ppm 12 x ampoules, NTMOS detectors Hydrogen Sulphide H 2 S 10 ppm GT3000 series Hydrogen Sulphide H 2 S 25 ppm GT3000 series Chlorine Cl 2 5 ppm GT3000 series Ammonia NH 3 50 ppm GT3000 series Ammonia NH ppm GT3000 series Hydrogen H ppm GT3000 series Oxygen O 2 20,90 % GT3000 series Carbon Monoxide CO 50 ppm GT3000 series Carbon Monoxide CO 250 ppm GT3000 series Sulfur Dioxide SO 2 10 ppm GT3000 series Sulfur Dioxide SO 2 50 ppm GT3000 series Hydrogen H 2 50 % LEL AutroPoint H Without gas AutroPoint H 2 Accessories for calibration kits Part number Description Calibration cup for catalytic detectors, stainless steel Calibration cup for point gas detectors AutroPoint H 2 S, O2 and TX Windshield calibration bag for AutroPoint HC200/ Extra ampoules for NTMOS Calibration Kit H 2 S Ampoule, 50 ppm GT3000 replacement cylinder H2S 50 ppm GT3000 replacement cylinder O2 20,90% GT3000 replacement cylinder H2S 25 ppm GT3000 replacement cylinder H2 500 ppm 116-Z Z Z Z Z Z Z Z Z Z Step regulator with 0,5 L constant flow Step regulator with 1 L constant flow Carrying case for 2 bottles 2.5 LPM constant flow regulator Test gas, 65 % LEL methane in N L Test gas, 50 ppm H 2 S. 110 L Test gas, 50 % LEL H L Sample Flow Housing for point gas detector GD-10P Viton hose pr. meter Reg. valve L/min Other concentrations and test gases available on request. 56

57 57 Gas detectors

58 Other detectors completing the fire detection system Alarmline linear heat detection (LHD) is a cable-based system providing economical temperature monitoring at the precise point of risk. The system is reliable, flexible and has the ability to detect abnormal temperature variances before fire breaks out. The comprehensive LHD product portfolio allows a vast range of commercial and industrial fire and overheat risks to be protected, in ambient temperatures of 68 C to 174 C. Other options/alarm temperatures available on request. Aspirating detectors function by sampling air via a network of pipes, sampled air is passed through a dust filter and into a detector chamber where the air is analyzed for traces of smoke. Typical applications include laboratories, large open spaces, corrosive environments, archives/historical buildings and industrial areas. Every detector is trainable for the specific environment in which it is installed. Common to all AutroSense detectors is that they are capable of detecting the small amounts of smoke that are generated in the initial phases of a smouldering fire, ensuring the earliest possible warning of a potential fire. At the same time, AutroSense detectors distinguish real smoke from dust and pollutants, reducing unwanted alarms to a minimum. AutroSense 200, AutroSense Micra 25 and Micra 100 are stand-alone aspirating detectors, that can also be connected to fire alarm systems. These units feature built-in intelligence that ensures optimal detection capability. Beam detectors are used in large open areas instead of a quantity of point smoke detectors. The detector protects a given area by sending signals (infrared light beam) between a transmitter and receiver, and detect dimmer or changes in frequency by heat or smoke. Beam detectors are suited to applications in open spaces where costs associated with point smoke detectors would be prohibitive. 58

59 Alarmline linear heat detectors Part number Description Alarmline analogue cable, K Interface unit (K82012F) for high-resistance sensor K82017 Other detectors Alarmline digital cable, 68 ºC nominal, H Alarmline digital cable, 68 ºC nominal, H8040N Alarmline digital cable, 85 ºC nominal, H Alarmline digital cable, 105 ºC nominal, H Alarmline digital cable, 174 ºC nominal, H8069 Accessories Part number Description Alarmline L-bracket Alarmline edge clip Alarmline T-clip Alarmline pipe clip Termination kit K EEXE Junction box tank roof Automatic cable reel Neoprene sleeve B Cable ty B

60 Aspirating detectors Image Part number Description Sensitivity (obsc./m) Max. length piping Max. coverage (FG) Max. coverage BS6266 (Hot Wire Test) Sampling pipe inlets Max. sampling holes Alarm levels Relays Aspirating detectors AutroSense 200 0, % 200 m 2000 m² 500 m² AutroSense Micra 25 0, % 25 m 450 m² 450 m² AutroSense Micra 100 0, % 100 m 1600 m² 500 m²

61 Accessories Part number Description AutroSense command module w/o PSU AutroSense Micra relay card w/inputs Other detectors AutroSense 200 dust filter AutroSense Micra 25 and 100 dust filter Wire burn unit Cable for hot wire test 100 m) 116-BWP BWP E-2446/1 116-E-2446/2 AutroSense, detector housing for sampling pipes with detector base BWA-100 AutroSense, detector housing for sampling pipes with detector base BWA-40A/1 Label for DET. POINT Label for sampling pipe Warning Piping halogen free Part number Description Straight pipe L=3 m HFBS 25 mm Bend 90GR HFNB 25 mm Joint HFSM 25 mm Cabinet gland HFAFT/MBS 25 mm Blind plug DPD mm Pipe fastener HFCL 25 mm Sealant HVKS Box 165 x 105 x 64 mm HPKGH 100 OP Capillary tube Ø=10 mm 16 mm piping delivered on request 61

62 Beam detectors Image Part number Description Detection distance Degree of protection AutroBeam 100, transmitter (Tx) m IP AutroBeam 100, receiver (Rx) m IP Fireray Auto aligning infrared optical beam detector. Transmitter/receiver in the same housing, plus reflector m IP Fireray Auto aligning infrared optical beam detector. Transmitter/receiver in the same housing, plus reflector m IP54 The AutroBeam 100 is delivered with interface unit BN-40A. Recommended interface unit for Fireray 5000 is BN-300/BN-320. For interfacing to fire detection systems, see I/O modules p. 11 Accessories Part number Description Calibration tool for AutroBeam SAC alarm simulator for AutroBeam m kit for Fireray 5000, included in Fireray Universal bracket for Fireray

63 63 Other detectors

64 OMICRON multilevel alarm systems solutions you can trust The Omicron multilevel alarm systems by Autronica include high level/overfill alarm systems, gas detection systems, tank and vapour pressure systems, temperature alarms and calibration equipment. Since delivery of the first generation independent high level system in 1989, we have developed a range of high-tech systems for the shipping and offshore industry. More than 5000 vessels are using multilevel alarm system equipment. The systems are designed to attract minimum maintenance overheads. We deliver reliable, service-friendly systems to meet owners and regulatory requirements. The systems fulfil IMO, IACS, EC, USCG and classification societies regulations. The Omicron systems are based largely on tailor made solutions for FPSOs, LNGs, LPGs, shuttle tankers and storage tankers. Therefore, we give you a short description of the complete systems rather than a description on part number level. Please contact us for more information. 64

65 Level alarm system OAS 5 For high level and overfill Omicron level alarm system OAS 5 with sensors is a complete level alarm system required either as an independent Overfill or High level and Overfill system on all type of tankers. When delivered as a dual point system it is approved as two independent systems as required in the regulations. Sensor Type HL-8903 for one level and type HHL-8903 for two levels. Special models for LNG/LPG vessels with more than two levels. This float type sensor works on a permanent magnet - reed switch principle. Features: n Does not require a specialist engineer for installation or start up n Proven to be very reliable n Two years guarantee n Covers all types of vessels (E.g. LNG,LPG, Chem, CT, PT etc.) n Type approved by all major classification societies n Extensive reference list n Short delivery times Omicron multilevel alarm systems Vapour alarm system OVS 2.1 OP For vapour return lines on tankers Omicron vapour alarm system OVS 2.1 OP monitors the oxygen content and the pressure in the waste vapour line(s) during loading of tank vessels. It consists of a detector cabinet mounted on deck with Eex ia approved oxygen and pressure sensors, flow fail initiator, manifold selector, test and purge facility. The electronic cabinet mounted in the cargo control room with alarm panel has individual LED displays and alarm status LEDs. Different models cover all configurations of manifolds and vapour lines. 65

66 Gas sampling system OGS 3.1 and OGS 3.11 For total solutions in gas sampling Omicron gas sampling system OGS 3.1 is our advanced model for special requirements. Different models and options cover most applications you will find onboard any kind of tankers with special needs. All delivered parts are completely assembled ready for interconnection to on-site application. OGS 3.1 is based on a scanning method, which means that sample points are being connected to sensor(s) in a cyclic sequence. The operator panel has an LCD display and individual LED lamps indicating each measuring point status. To minimize scanning cycle time and guarantee fresh samples at all times, the system has two vacuum pumps. One main pump, continuously sucking from all sample points and a smaller sample pump taking samples from the actual point according to the sequence. This insures quick response if gas is detected. Purging of sample line is done immediately after each sampling is finished. New design of the well known OGS 3.1 gas sampling system (smaller and more compact). Gas sampling systems can be used in all spaces where gas detection is requested, and they can handle several gasses simultaneously. Our systems have the unique automatic blowback feature, which together with two sampling pumps create a rapid and clean sampling cycle. Hence, for gas tankers we are able to handle more points and still maintain the 30 minute rule of IMO Gas Code. Standard features: n Infrared hydrocarbon sensor with range % L.E.L n Low and high gas alarms n Flame arrestor and shut-off valve for each sampling tube n Automatic and sequential purging of each sampling tube n Manual disconnection of sampling points not in use (e.g. when water in ballast tanks) n Two vacuum pumps (main and sample) n Non-return valves mounted on deck for ballast tanks in order to avoid liquid entering into the system n Extensive hardware and software system monitoring Optional features: n Up to 5 additional units with control transfer function. n Multiple operating panels n Remote alarm unit. Simple alarm status panel with LEDs and buzzer (e.g. for Bridge) n Aux. relay outputs. Up to 32 relay outputs, freely configurable to any sample point n Standby pump with manual switch over n Dual purge supply (E.g. nitrogen and instrument air) n Multi-gas detection. Up to 3 different gas sensors can be installed n Alarm printer n Bulkhead penetrations n Automatic disconnection of sample line when sample point is manually disconnected from scanning cycle n RS 485/422 MODBUS RTU serial line output to external computer n Custom made systems on request 66

67 Fixed gas detection system OGS 2.1 For cargo pump room and other applications and type of vessels Omicron fixed gas detection system OGS 2.1 is intended for pump rooms, AC inlets (ISGOTT 5th edition) and other areas. The sensors are based on Eex d approval. The most common gas sensor types are hydrocarbon, oxygen and hydrogen sulphide. The system can independently handle an infinite number of sensors. Each alarm unit have an individual display, 4 adjustable independent alarm setpoints and possibilities for voting. Furthermore, each alarm unit has separate alarm LEDS for system/sensor failures. Omicron fixed gas detection system OGS 2.1 is a micro controller based gas detection system for pump rooms. The system is complete with sensors and connection points. The OGS 2.1 can be delivered as a split version with the alarm panel mounted in a separate cabinet. Omicron multilevel alarm systems The alarm panel has individual displays, alarm LEDs for all gasses, and system alarms. The system will be factory adjusted to give an alarm at a specific gas level, but can easily be set to other levels without any instruments. As standard are potential free output relay contacts for power failure and common system failure, in addition to a common relay for each gas type that the system is configured for. The system also drives a bridge remote alarm panel. Standard features: n Combustible type hydrocarbon sensor n Electrochemical oxygen sensor n Electrochemical hydrogen sulfide sensor n Power failure relay output n Common gas alarm relay output (for each gas type) n Common system alarm relay output n Bridge remote panel Optional features: n IR hydrocarbon sensors n O 2 sensors. n H 2 S sensors n RS485/-422 serial line (MODBUS RTU) n Cargo pumps emergency shut down function. n Integrated temperature alarm system for cargo pump bearings n Other gas types on request 67

68 Direct gas sampling system OGS 2.1 sampling Gas detection in harsh areas such as shale shaker rooms etc. Omicron direct gas sampling system OGS 2.1 sampling is specially made for direct detection of harsh areas. Principle The direct gas sampling system consists of two cabinets; one detector cabinet approved for mounting in a Zone 1 area, and one electronic cabinet with power supply, barrier units and alarm panel typically mounted in the cargo control room (CCR). The dual sampling lines cover the same sampling location. A built-in purging feature, cleaning the lines sequentially with overlapping detection (line 1 & 2), provides continuous and reliable detection at the monitored area. Ventilation pipe Gas alarm Flow fault Vacuum pump High pressure air Tube/pipe flushing 68

69 Water ingress system OAS WI For high level and overfill The Omicron water ingress system has been specially designed and manufactured for detecting the presence of water in the inner bottom in any holds reaching a height of 0,5 m and another height of not less than 15 % of the depth of hold but not more than 2 m. Furthermore, also holds located partially or totally forward of the foremost cargo hold, and ballast tanks located forward of the foremost cargo hold, collision bulkhead of Bulk carrier, in conformity with SOLAS regulation XII/ 12 rule requirement The system consists of a main alarm panel with cabinet and level sensor operated by detecting the conductivity in a liquid when present. The sensor and the alarm panel are connected together with an intrinsically safe barrier. When the presence of water has reached the detecting points (ref. rule requirement) of level sensor installed at the preset level in the cargo hold or other space, the electric signals which are activated on the level switches are transmitted to the main alarm panel. At the same time, the audible and visual alarms are activated on the main alarm panel. The system has also all necessary functions like loop monitoring of sensors and power failure. An overriding device ensures that the alarm can be deactivated or reactivated for the detector installed in the tank and holds used for carriage of water ballast according to the SOLAS regulation XIII The main power and standby power are prepared in such way that if the main power fails, the standby power will provide continuous power to the alarm panel, and an alarm will be given. Omicron multilevel alarm systems The sensor: Type WI-22 designed for various locations onboard a bulk carrier. The construction is unique with the following advantages: n Complete unit in stainless steel. n Non movable parts due to conductivity principle. n Classified as simple apparatus n IP68/ 2.5 bar with 35 m signal cable and mounting bracket included. n Tested working temperature -25 to 120 C. n Easy to function test. n Designed without any active electronic components on deck. n Can operate in all sorts of bulk cargoes. The alarm cabinet: Type OAS is a complete signal monitoring and alarm unit which is delivered for three alarm sensors per cargo hold. The third channel (free of charge ) can be used for alarm sensor on top of the cargo for covering water penetration through hatch covers. n Intrinsically safe connections to sensors. n Potential free contacts for common external alarms and light & horn. n All normal alarm functions. n Optional RS485/-422 serial line communication with host computer. n The Alarm Panel can either be mounted in the front door of the alarm cabinet or in a common console. n Power supply: 115/230 VAC, Emergency power supply 24 VDC 69

70 Temperature calibrator OTE-T700 The temperature calibrator is intended for testing of temperature sensors, indicators, switches and safety equipment. The heating medium is hot air. This makes it clean to use and it has quick temperature change response. The tempera ture range is about 10 C above ambient to C with digital readout of the measured temperature. Technical specifications: n Measuring range: ~ ºC n Heating medium: Air n Display: 15 mm 3,5 digit LCD n Dimensions: 410 x 140 x 160 mm n Weight: 4 kg n Power: 120V - 50/60 Hz W, 230V - 50/60 Hz W n Accuracy up to 100º C: +/- 1 ºC, ºC: +/- 1 % FS, ºC: +/- 2 % FS Pressure calibrator OTE-P202 and OTE-P300 The pressure calibrators are intended for testing of pressure sensors, indicators, switches and safety equipment. The pressure medium is oil. It has fine adjustment of the pressure, and an overpressure relief valve. The digital readout can be selected to Bar or PSI. Pressure range is bar / bar. The unit can also be delivered in Eex version. Technical specifications: n Measuring range: Bar / PSI // Bar PSI n Pressure medium: Oil n Display: 15 mm 3,5 Digit LCD n Dimensions: 310 x 115 x 135 mm n Weight: 5 kg n Hose length: 1,5 m with quick connector and 40 mm test cock n Power: 1 pc. 9 V battery n Accuracy 0-10 Bar: : +/- 0.2 Bar Bar: +/ % F.s Bar: +/ % F.s. 70

Loop units. a wide range covering your basic fire detection needs

Loop units. a wide range covering your basic fire detection needs Loop units a wide range covering your basic fire detection needs We provide a wide range of loop units for our fire detection systems. Our detectors, manual call points, I/O units, control units and alarm

More information

Autronica Fire and Security PRODUCTS Fire and gas safety Division Petrochemical, Oil & Gas

Autronica Fire and Security PRODUCTS Fire and gas safety Division Petrochemical, Oil & Gas Autronica Fire and Security PRODUCTS 2017 Fire and gas safety Division Petrochemical, Oil & Gas Autronica Fire and Security is a leading innovator, manufacturer and supplier of fire and gas safety worldwide.

More information

AUTROSAFE 4 A new level in interactive fire detection systems

AUTROSAFE 4 A new level in interactive fire detection systems AUTROSAFE 4 A new level in interactive fire detection systems Autronica Fire and Security AS Protecting life, environment and property... Proven, reliable and now even better AutroSafe 4 the next generation

More information

Protecting life, environment and property PRODUCTS Maritime. Autronica Fire and Security AS

Protecting life, environment and property PRODUCTS Maritime. Autronica Fire and Security AS Protecting life, environment and property PRODUCTS 2013 Maritime Protecting life, environment and property Contents AutroSafe....4 Panels AutroSafe 4.... 6 Panel kits....7 Switches...8 Printer....9 Modules....10

More information

Autronica Fire and Security PRODUCTS Fire and gas safety Division Maritime

Autronica Fire and Security PRODUCTS Fire and gas safety Division Maritime Autronica Fire and Security PRODUCTS 2017 Fire and gas safety Division Maritime Autronica Fire and Security is a leading innovator, manufacturer and supplier of fire and gas safety worldwide. Our products

More information

Autronica Fire and Security PRODUCTS Fire and gas safety Division Maritime

Autronica Fire and Security PRODUCTS Fire and gas safety Division Maritime Autronica Fire and Security PRODUCTS 2016 Fire and gas safety Division Maritime Autronica Fire and Security is a leading innovator, manufacturer and supplier of fire and gas safety worldwide. Our products

More information

PRODUCTS Fire and gas safety by Autronica Fire and Security. Division petrochemical, oil and gas

PRODUCTS Fire and gas safety by Autronica Fire and Security. Division petrochemical, oil and gas PRODUCTS 2019 Fire and gas safety by Autronica Fire and Security Division petrochemical, oil and gas CONTENTS AutroSafe integrated fire and gas... 4 Panels....6 Panel kits.... 7 Loop panels...8 Switches

More information

AUTROSAFE. An interactive fire detection system for larger vessels

AUTROSAFE. An interactive fire detection system for larger vessels AUTROSAFE An interactive fire detection system for larger vessels AUTROSAFE AutroSafe interactive fire detection system is designed for the toughest requirements and expands the possibilities of a fire

More information

PRODUCTS 2014 Autronica Fire and Security AS. Protecting life, environment and property

PRODUCTS 2014 Autronica Fire and Security AS. Protecting life, environment and property Protecting life, environment and property PRODUCTS 2014 CONTENTS AUTROSAFE 4 FIRE DETECTION SYSTEM...4 Panels.... 6 Panel kits.... 7 Switches... 8 Printer... 9 Modules.... 10 Communication... 12 Service

More information

PRODUCT CATALOGUE. Autronica Fire and Security AS Petrochemical, Oil & Gas.

PRODUCT CATALOGUE. Autronica Fire and Security AS Petrochemical, Oil & Gas. PRODUCT CATALOGUE http://autronica.nt-rt.ru/ По вопросам продаж и поддержки обращайтесь: Архангельск (8182)63-90-72 Астана +7(7172)727-132 Белгород (4722)40-23-64 Брянск (4832)59-03-52 Владивосток (423)249-28-31

More information

PRODUCT CATALOGUE. Autronica Fire and Security AS Maritime

PRODUCT CATALOGUE. Autronica Fire and Security AS Maritime 2015 PRODUCT CATALOGUE Autronica Fire and Security is a leading innovator, manufacturer and supplier of fire and gas safety worldwide. Our products ensure safety in applications on land, sea and in the

More information

Autronica Fire and Security PRODUCTS Fire safety Division Onshore Global

Autronica Fire and Security PRODUCTS Fire safety Division Onshore Global Autronica Fire and Security PRODUCTS 2016 Fire safety Division Onshore Global Autronica Fire and Security is a leading innovator, manufacturer and supplier of fire and gas safety worldwide. Our products

More information

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations AutroSafe interactive fire detection system AUTROSAFE An interactive fire detection system for complex installations AUTROSAFE AutroSafe interactive fire detection system is designed to meet the toughest

More information

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT Project No: 0003053331 Supplements Project No.: 3034449 Class: 3010 Product Name: BU-110 and BV-110 Loop

More information

System Design and Engineering AutroSafe Interactive Fire & Gas Detection System (IFG)

System Design and Engineering AutroSafe Interactive Fire & Gas Detection System (IFG) System Design and Engineering AutroSafe Interactive Fire & Gas Detection System (IFG) 116-P-SYSDEENGIN-IFG/XGB, Rev. A, 2015-08-14, Autronica Fire And Security AS COPYRIGHT This publication, or parts thereof,

More information

System Description AutroMaster ISEMS - Integrated Safety and Emergency Management System

System Description AutroMaster ISEMS - Integrated Safety and Emergency Management System System Description AutroMaster ISEMS - Integrated Safety and Emergency Management System 116-P-AMASTER-SYSTEM/XGB, Rev. C, 2016-05-20, Autronica Fire And Security AS COPYRIGHT This publication, or parts

More information

Release 4. System Description. AutroSafe Interactive Fire Detection System. 116-P-ASAFE-SYSTEMD/EGB Rev. H, , Autronica Fire And Security AS

Release 4. System Description. AutroSafe Interactive Fire Detection System. 116-P-ASAFE-SYSTEMD/EGB Rev. H, , Autronica Fire And Security AS p Release 4 System Description AutroSafe Interactive Fire Detection System 116-P-ASAFE-SYSTEMD/EGB Rev. H, Autronica Fire And Security AS COPYRIGHT This publication, or parts thereof, may not be reproduced

More information

Autronica Fire and Security AS ID:

Autronica Fire and Security AS ID: 1 1 Autronica Fire and Security AS A leading innovator, manufacturer and supplier of fire & gas detection equipment Founded in 1957 in Trondheim, Norway Protecting life, environment and property 2 Fire

More information

Fire and Gas Monitoring Panel ST7-HV

Fire and Gas Monitoring Panel ST7-HV Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content

More information

Панели. AutroSafe 4. Технические характеристики

Панели. AutroSafe 4. Технические характеристики Панели AutroSafe 4 Технические характеристики Архангельск (8182)63-90-72 Астана +7(7172)727-132 Белгород (4722)40-23-64 Брянск (4832)59-03-52 Владивосток (423)249-28-31 Волгоград (844)278-03-48 Вологда

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring GE Security FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring Version v2-2 / September 2005 Aritech and Kilsen are GE Security brands. http://www.geindustrial.com/ge-interlogix/emea

More information

System Description AutroMaster V Presentation System

System Description AutroMaster V Presentation System System Description AutroMaster V Presentation System AMASTERV-SYSTEM/XGB, Rev. B, 2018-05-07, Autronica Fire And Security AS COPYRIGHT This publication, or parts thereof, may not be reproduced in any form,

More information

Fire alarm system EBL512 G3

Fire alarm system EBL512 G3 Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Third generation. www.panasonic-fire-security.com 2010-04-23 Page 1 of 6 The demands

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DUAL MONITORED INPUT/OUTPUT UNIT BN-305 DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

YOUR PARTNER IN FIRE & GAS DETECTION

YOUR PARTNER IN FIRE & GAS DETECTION YOUR PARTNER IN FIRE & GAS DETECTION OGGIONI s.a.s. Via Lavoratori Autobianchi, 1 - P.T.B. Edif.13/O - 20832 Desio (MB) Italy Tel.+39 0362 629135 Fax. +39 0362 622531 www.oggionisas.com - info@oggionisas.com

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

System Description Autroprime Interactive Fire Detection System

System Description Autroprime Interactive Fire Detection System System Description Autroprime Interactive Fire Detection System 116-P-APRIME2-SYSTEM/XGB, Rev. B, 2018-03-23, Autronica Fire And Security AS COPYRIGHT This publication, or parts thereof, may not be reproduced

More information

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range Fire Detection MINERVA Marine MX T2000 Panel Range Features: Enhances fire detection and eliminates unwanted alarms using fuzzy logic Assists fire fighting and training by providing on-screen risk management

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

FC723 Fire control panel

FC723 Fire control panel FC723 Fire control panel FS720 series (IP5) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 756 addresses Processes

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

SINGLE MONITORED INPUT UNIT BN-303

SINGLE MONITORED INPUT UNIT BN-303 SINGLE MONITORED INPUT UNIT BN-303 Interactive fire detection system Product Datasheet Features Interactive For interfacing switches and 3rd party detectors with relay outputs to Autronica s interactive

More information

Different types of Fire Alarm System

Different types of Fire Alarm System Different types of Fire Alarm System Conventional Fire System Generally comes with Zones. Each zone can have max 20 detectors. Addressable Fire Alarm System This comes in loops. Different manufacturer

More information

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features 990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

Fire control panels FC726 FC726-XA

Fire control panels FC726 FC726-XA Fire control panels FC726 FC726-XA Modular, pre-confectioned, microprocessor-controlled fire control panel for up to max. 1512 device addresses Integrated, user-friendly operating unit Detection and automatic

More information

Synova TM product catalog.

Synova TM product catalog. Synova product catalog Synova TM product catalog. Fire protection products and accessories. Siemens Switzerland Ltd Building Technologies Group International Headquarters Gubelstrasse 22 CH-6301 Zug Tel

More information

IGD.CO.UK

IGD.CO.UK APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (MPXS) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series The ECL Comfort 210 is an electronic weather compensated

More information

Installation Handbook. Interactive Fire Alarm System Release 3. Operator Panel, BS-330. Protecting life, environment and property...

Installation Handbook. Interactive Fire Alarm System Release 3. Operator Panel, BS-330. Protecting life, environment and property... Interactive Fire Alarm System Release 3 Installation Handbook Operator Panel, BS-330 Protecting life, environment and property... P-ASAFE/OP/DE Rev. A, 010531 COPYRIGHT This publication, or parts thereof,

More information

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series ECL 210 The ECL Comfort 210 is an electronic weather

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

BS-100 DYFI. Installation handbook. Protecting environment, life and property... P-BS100/DCE

BS-100 DYFI. Installation handbook.  Protecting environment, life and property... P-BS100/DCE BS-100 DYFI Protecting environment, life and property... P-BS100/DCE P-BS100/DCE/Doc/961023 2 Autronica Fire and Security AS Contents Please observe! This handbook contains installation instructions for

More information

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware

More information

FC700A Fire detection control unit

FC700A Fire detection control unit FC700A Fire detection control unit Synova 4-16 Loop analogue addressable control panel 128 devices per loop (SynoLOOP) and up to 1000 devices per panel Up to 24 collective lines for Synova TM 600 serie

More information

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable Protec Protec Fire Detection Pty Ltd Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE CAUTION

More information

Security Alarm Systems

Security Alarm Systems eclipse Security Alarm Systems Contents Introduction 2 System Configuration 3 Control Panels 4 Remote Keypads & Expanders 5 Communication Modules 6 Upload/Download 6 Specifications 7 Introduction Zeta

More information

SUPREMATouch Modular Fire & Gas Detection System

SUPREMATouch Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Because every life has a purpose Class Leading Fire & Gas Detection Solutions MSA s permanent gas detection systems are relied upon by a huge number of

More information

ZXSe Range Data Sheet

ZXSe Range Data Sheet ZXSe Range Data Sheet Analogue addressable fire alarm control panel Product Overview The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and

More information

Advanced FireAlarm Panel 1-4Loop

Advanced FireAlarm Panel 1-4Loop Advanced FireAlarm Panel 1-4Loop Advanced Technologies Advanced Electronics Ltd IP Gateway Monitoring and interrogation via the internet Password protected multiple user permissions Event notification

More information

FC2020 Fire control panel

FC2020 Fire control panel FC2020 Fire control panel Series FS20 (MP4.0) Sinteso Compact, prefabricated, microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as stand-alone

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features Fire Safety ZXSe Range Analogue addressable fire alarm control panel The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor

More information

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent

More information

RAYCHEM NGC-30 COMPONENTS

RAYCHEM NGC-30 COMPONENTS PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network Protec Protec Fire Detection plc Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE

More information

F&G detection system for LNG plants

F&G detection system for LNG plants LNG PLANT F&G detection system for LNG plants The historical safety record for the LNG industry is strong. Engineering, installation and lifetime use takes into account the well known hazards of such an

More information

Touchpoint Pro Flexible Gas Control System

Touchpoint Pro Flexible Gas Control System Gas Detection Touchpoint Pro Flexible Gas Control System THE IDEAL SAFETY SYSTEM Honeywell s Touchpoint Pro makes gas control system design, installation, configuration and operation simple. Touchpoint

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

Gas Controller Module GC-06

Gas Controller Module GC-06 Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System DIVA8MG2 Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Compact PAVA System Master Unit DIVA8 System DIVA8 system

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm. E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0E FL0E FL0E mm mm 0 mm DESCRIPTION The LT FL0 Series is part of the Fire Alarm Aspiration

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide. Who we are? - Nº 1 Spanish fire alarm systems manufacturer. - 25 years experience in the fire detection field. - 40 countries worldwide. Own engineering, design and factories. Total control of production

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj Control Equipment Limited 32 Zone, 40 Character Discovery Panel, Voyager Panel and Integra Network Repeater Installation, Commissioning

More information

Fire Detection Systems Product Catalogue (Version )

Fire Detection Systems Product Catalogue (Version ) Fire Detection Systems Product Catalogue (Version 2015-01) Version 2015-01 Product Catalogue Fire Detection Systems This product catalogue is intended for sales purposes only. For planning, installation,

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

ONYXWORKS AND FIRSTVISION. Version 4

ONYXWORKS AND FIRSTVISION. Version 4 ONYXWORKS AND FIRSTVISION Version 4 Version 4: Next Generation CONNECTED SOLUTIONS ONYXWorks FirstVision 2 ONYXWORKS Version 4 New to ONYXWorks v4.30 Look Ahead Test Monitoring Configuration Tool Display

More information

Design. Innovations in Integrated Control Systems

Design. Innovations in Integrated Control Systems Design Innovations in Integrated Control Systems Halvard Foss Kongsberg Maritime AS October 17-18, 2006 Return to Session Directory Innovations in Integrated Control Systems Halvard Foss Kongsberg Maritime

More information

Frequently asked questions: Intelligent Transmitter Series

Frequently asked questions: Intelligent Transmitter Series Frequently asked questions: Intelligent Transmitter Series The Wilcoxon family of Intelligent Transmitters, relay alarms, and communication modules can be used to implement low-cost online vibration monitoring

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY Agenda 1 Challenges in the Process Industry International codes and standards F&G in an industrial Facility Honeywell s industrial F&G

More information

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control Reliably Advanced Extinguishing Control The Best Choice for Asset Protection What suppression and extinguishant control panel would you choose to protect the literary collection of an entire nation? 47

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 3 Our integrated security solutions

More information

NGC-40 Advanced Heat-Tracing Control System

NGC-40 Advanced Heat-Tracing Control System NGC-40 Advanced Heat-Tracing Control System Local configuration and monitoring with Raychem Touch 1500 touch screen display Heat-tracing system NGC-40 system Remote configuration and monitoring with Raychem

More information

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS Engineering Guideline pac-carriers Type 9195 for Yokogawa ProSafe-RS 2 Engineering Guideline / Yokogawa ProSafe-RS 06.06.2017 Integrated solutions for Yokogawa R. STAHL offers a wide range of customized

More information

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property... Interactive Fire Alarm System Release 3 Operator's Handbook Information Panel, BV-320 Protecting life, environment and property... ASAFE-IN/FE Rev. A, 010531 COPYRIGHT This publication, or parts thereof,

More information

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours Dräger Polytron Pulsar 2 Detection of flammable gases and vapours The Dräger Polytron Pulsar 2 is the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard

More information

Basic Fire Alarm SystemTraining. Arman Alnasar

Basic Fire Alarm SystemTraining. Arman Alnasar Basic Fire Alarm SystemTraining Arman Alnasar Agenda Introduction to Esser 10 min Product Overview 5 min Control Panels 30 min Detectors 20 min Field Devices Alarm Devices 20min 10 min Management & Interface

More information

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC Take Fire Protection to the Next Level Fire Products from DSC AFD2000 Addressable Fire Control Panel Series Provides Maximum Flexibility The new AFD2000 is a completely programmable series of addressable,

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

Touch Screen 1 loop Addressable Fire Alarm Panel

Touch Screen 1 loop Addressable Fire Alarm Panel evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide Product Overview The IntelliKnight 5820XL is an intelligent addressable fire alarm control panel designed for flexibility and reliability.

More information