ixarmaxml Driver configuration
|
|
- Ami Wade
- 5 years ago
- Views:
Transcription
1 MICROMEDIA INTERNATIONAL ALERT: Driver - ixarmaxml ALERT Alarm Monitoring and Advanced Call- Management Author: Jens Eberle Sites: 10 Company: Micromedia International Date: 12/4/ Version: Ref. : ALERT_Treiber ixarmaxml_en.docx [Kommentare ] ixarmaxml Driver configuration Mailing To CC Company Attachments 04/12/ ixarmaxml Driver configuration 1/10
2 Content Alarm Monitoring and Advanced Call-Management... 1 Introduction... 3 Requirements... 3 ixarma Connection Data... 3 ALERT - ixarma connection... 3 ALERT ixarma Driver Interface... 4 Service Message (Send a Message )... 5 Two types of alarm cases... 5 Used parameters of the alarm definition window... 6 Alarm creation in ixarma (dynamic/static)... 7 Additional User - Commands... 8 Redundancy... 9 Alert.ini ixarmaxml.ini configuration /12/ ixarmaxml Driver configuration 2/10
3 Introduction ixarma is a web based server system to monitor safety and building equipment. This document describes the connection type between ALERT (client) and the ixarma web server. Requirements ALERT Version 3.6 rev. 1 Build 27 or higher IXARMAXML license option must be activated System requirements correspond to the requirements of ALERT. Link: compatibility and system requirements or visit and go to SUPPORT\FAQ\ALERT. ixarma Connection Data To connect to the ixarma web server following information are needed: URL (Master) Recommended, TCP/IP Port 443 (HTTPS), allow incoming and outcoing traffic. From version and later the HTTP protocol and the TCP/IP port definition was implemented, e.g. GET/POST Method differentiation (default, GET) User name Password To use the redundant mode o URL (Slave) 2. and if applicable the URL of the 3. web server ALERT - ixarma connection It s a client/server connection, where ALERT act as client. We differ two ways: a. Direct mode The ixarma Server URL will be directly used in the address bar of the user media. Switching to the redundant URL, will happen after the call cycles failed - according to the team or user call definition. 04/12/ ixarmaxml Driver configuration 3/10
4 b. Heartbeat/redundant mode (recommended on bad quality networks) The URL will be defined in the driver GUI, after the successful configuration of the access data, a query request (Heartbeat) will be sent from ALERT to the ixarma server to check if the server is reachable. The Timeout to send Heartbeat (s) can be defined in the drivers interface. Also the retry Heartbeat period can be configured, it means, if the defined amount of reties was reached and the redundant mode is activated, the driver will change to one of the slave URLs. ATTENTION: When changing from one mode to the other one, please make sure that the address bar of the user media is direct mode or heartbeat mode confirm! ALERT ixarma Driver Interface Here you will see the Graphical User Interface (GUI) of the ixarma driver, it serves the configuration of the driver. ALERT driver name System ID Automatic call acknowledgement, please activate it! At now, there is no option available of the ixarma server to do the call acknowledgement automatically. To show the driver activities in the journal Each alarm in ALERT will send one alarm to ixarma.please check the box, otherwise only the last alarm will be send. Heartbeat Tiemout, should be bigger than one minute, otherwise the ixarma server can refuse the request. If Hearbeat = 0 the redundant mode will be disabled! Hearbeat retries: Amount of attempts before switching to the slave URLs Username and password, all Servers (Master/Slave) are using the same login data. Direct URL mode, if axtivie, the Heartbeat-/Redundanz mode will be switched off. Please set then the URL directly in the address bar URL (Master) if the redundant mode is activated, please configure the Slave URLs (URL2, URL3). 04/12/ ixarmaxml Driver configuration 4/10
5 Service Message (Send a Message ) According to the ixarma specification, there are 4 event types of an alarm, set (K), reset (G), acknowledge (Q) and set&reset ($). In the case sending a user message ( send a message of ALERT) then the set&reset event will be used. This means the alarm in ixarma will be only once triggered and call its procedure just once, then abort. Please use the short message field to define the alarm which should be set in ixarma = alarm point id <apid>. Please note, by sending a service message the <bez> will be ServiceCallofALERT and the <family> will be ALERT. Two types of alarm cases When there is an alarm in ALERT, an alarm request will be send to the ixarma web server. If ALERT receives an OK the call will be acknowledged, otherwise if it will receive a NOTOK ALERT will follow its call cycle definition. Case 1: In the Alarm definition window of ALERT, a set and reset (optional acknowledgement) action must be used, otherwise the Alarm in ixarma will not be set back. If the same alarm will be triggered a second time the alarm in ixarma will do nothing. 04/12/ ixarmaxml Driver configuration 5/10
6 Case 2: When using the in the user driver address field, an alarm in ixarma will be set with a following reset. In this case ALERT must not send extra a reset/ack to the ixarma server. This means an alarm procedure will only once triggered in ixaram and after the procedure abort. Used parameters of the alarm definition window To send a message to ixarma the driver is generating a XML string. In ALERT following fields are used. In the image below you will see the relation between ALERT and ixarma. 1. Alarm name in ALERT is the Alarm identifier in ixarma 2. priority, in ixarma only allowed 0 3! 3. Alarm processing = K (Kommend) 4. Reset = G (Gehend) Acknowledgement = Q (Quittieren) 5. Alarmmessage = Alarmtext 6. Shortmessage in ALERT is the AlarmPoint ID in ixarma (this will be set the ALARM!) 7. Alarm group of alert = Alarmpläne <family> XML Strin (green) of the image above: this message will be sent to ixarma. /AlarmService/alarm?version=1&xml=<msg><apid>DPALERT</apid><sysid>JENSEBERLE- PC</sysid><event>K</event><bez>DPALERT1</bez><prio>0</prio><family> </family><callerid>alert</callerid><text><![cdata[dpalert1 Alarm kommend]]></text></msg> 04/12/ ixarmaxml Driver configuration 6/10
7 ATTENTION: The alarm reset and acknowledgement action configuration must use the same short message field entries and the same call groups as the alarm processing action. If the alarm reset and acknowledgement action aren t used, please use then the address field of the driver in the user settings, please set the Recommendation: If using the alarm reset and acknowledgement action, use command for the first ixarmaxml Driver and the second one without parameter. This will do a reset of the alarm in ixarma before setting it. This is a kind of a protecting mechanism to make sure the alarm on the server will be set! Alarm creation in ixarma (dynamic/static) The ixarma server can allow dynamic alarm creation. For this reason a script, running on the ixarma server must be modified to evaluate the request of ALERT. Otherwise (static), an alarm must be created and exist on the ixarma server before trigger an alarm in ALERT.!STATIC! - If an alarm will be raised in ALERT, but isn t configured on the ixarma server, nothing will happen. 04/12/ ixarmaxml Driver configuration 7/10
8 Additional User - Commands It s possible to add specific commands to the number/address field of the user media ixarmaxml Driver. So it s possible to add the to set = K, reset = G and to do a set and reset = $ of an event in ixarma. an alarm point can be directly set on the server. If using the Direct Mode, first the URL must be entered followed by the commands, e.g.: This is used for special cases, please find the commands here in describes a set event: describes a reset event: describes an ack event: describes a set with follwoing reset event: <apid>$alarmpunktid</apid> in this case the <event> is always defined a K in = <apid$*alarmpunktid>, please ask = send query request to the ixarma Choose the GET or POST method, default GET, see ini when used an alarm point can directly be created in ixama by using the address bar of the users media. Attention, this command must be placed after the other @SYSID: will set the System ID = = <family> The following screenshot shows an example configuration used in direct mode. 04/12/ ixarmaxml Driver configuration 8/10
9 Attention: using the command parameters will override the default ones. It means, the URL in the address bar is having a higher priority that the definition of the ixarmaxml Driver GUI, it s also the same for family, sysid, etc. Redundancy Direct mode Per Team If the first user in a team cannot be reached the relief user (with the redundant URL) will be called. Or per user Heartbeat mode The redundancy only works if the Heartbeat Timeout is greater than 0 and when the Redundant mode is activated. Hearbeat retries, defines the amount of heartbeats with failure before switching to a slave URL. If no slave URL will work, the original master URL will be set. In this case, please verify the URL, Firewall settings,login date and the readiness of the ixarma server. During this time the heartbeat method is running in a loop mode and checks the ixarma driver configuration each minute. 04/12/ ixarmaxml Driver configuration 9/10
10 Alert.ini If the ixarmaxml.dll wasn t installed during the setup, please add follwing entriy to the [drivers] section: ixarmaxml=4700,ixarmaxml.dll,0,3 Info: Please don t forget to enable the license option! Only after the activation or in demo mode the ixarmaxml driver will work. ixarmaxml.ini configuration To enable the advanced driver log of ixarmaxml, please set the parameter TraceInFile to TRUE afterwards with the next restart of ALERT the ixarmaxml_log.txt will be created (if the heartbeat mode is activated and the timeout is set to 1 minute, the file size per day will around 500KBs.). 04/12/ ixarmaxml Driver configuration 10/10
Alarm handling by SMS in ALERT
Micromedia International Alarm handling by SMS Author: Jens Eberle Pages : 9 Company: Micromedia International Date : 29/10/2013 Version : 1.1 Réf. : Alarm Handling by SMS.docx [Commentaires ] Alarm handling
More informationMultiSite Manager. Setup Guide
MultiSite Manager Setup Guide Contents 1. Introduction... 2 How MultiSite Manager works... 2 How MultiSite Manager is implemented... 2 2. MultiSite Manager requirements... 3 Operating System requirements...
More informationBlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.
BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.3, October 2017 Copyright 2017 BlackBerry Limited. All Rights Reserved.
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev2 Copyright 2011 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation
More informationAlarm module for leak detection with webserver
This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer
More informationIon Gateway Cellular Gateway and Wireless Sensors
Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the
More informationIndigoVision Alarm Panel. User Guide
IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE
More informationManaging Network Alarms and Events
9 CHAPTER Prime Performance Manager allows you to view alarms and events that occur in your network. The following topics provide information about displaying network alarms and events: Displaying Active
More informationPlease use authentic SATA hard drive, USB device and battery.
Note The device should be set in the room with good ventilation, far from water, hot reservoir or dust. Network Video Recorder is not designed to be used outdoor. Please use authentic SATA hard drive,
More informationBosch TCU Integration Module Administrator's Guide
Bosch TCU Integration Module 1.0 - Administrator's Guide 10 Dec 2008 Rev 1.2 Table of Contents 1 Overview... 3 1.1 Compatibility...3 1.2 References...3 2 Installation... 4 3 Configuration... 5 3.1 System
More informationAdemco Vista Alarm Panel
System Galaxy Quick Guide CONFIGURATION AND OPERATION Ademco Vista Alarm Panel JAN 2018 SG 10.5.6 System Galaxy Quick Guide For Ademco Vista Panel Configuration & Operation 2nd edition JAN 2018 Information
More informationAvigilon Control Center 5 System Integration Guide
Avigilon Control Center 5 System Integration Guide for Paxton Net2 Access Control Systems 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted with
More informationHERCULES 6 GRAPHICS SYSTEM
HERCULES 6 GRAPHICS SYSTEM USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web: www.protec.co.uk
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation
More informationAlarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9
Alarm Client Installation and User Guide NEC NEC Corporation May 2009 NDA-30364, Revision 9 Liability Disclaimer NEC Corporation reserves the right to change the specifications, functions, or features,
More informationSetting up and Managing Alarms in McAfee ESM 10.x
McAfee SIEM Alarms Setting up and Managing Alarms in McAfee ESM 10.x Introduction McAfee SIEM provides the ability to send alarms on a multitude of conditions. These alarms allow for users to be notified
More informationYokogawa DX Ethernet Driver Help Kepware Technologies
Yokogawa DX Ethernet Driver Help 2012 Kepware Technologies 2 Table of Contents Table of Contents 2 4 Overview 4 Device Setup 5 Communications Parameters 7 Optimizing Your Ethernet Communications 9 Data
More informationYokogawa DX Ethernet Driver PTC Inc. All Rights Reserved.
2017 PTC Inc. All Rights Reserved. 2 Table of Contents 1 Table of Contents 2 4 Overview 4 Setup 5 Channel Properties - General 5 Channel Properties - Ethernet Communications 6 Channel Properties - Write
More informationSecurity Escort Central Console Software SE2000 Series
Release Notes Security Escort Central Console Software SE2000 Series Table of Contents 1 Security Escort v2.18.1.0... 2 1.1 Enhancements... 2 1.2 Errors Fixed... 2 1.3 Known Limitations and Restrictions...
More informationSystem Galaxy Quick Guide
System Galaxy Quick Guide CONFIGURATION AND OPERATION Integrating CCTV with System Galaxy JAN 2019 SG 11.1.0.2 System Galaxy Quick Guide For CCTV Integration Configuration & Operation Information in this
More informationNetwork Hardware and wiring (quiz)...
4120 Network/TSW (FA049) Course Agenda Day 1 Course Introduction (Presentation)... 8:00 am to 8:30 am Break Module 1 Installing and Configuring Network Software Applications 4120 New Network Programmer
More informationProliphix. Remote Management. User Guide
Proliphix Remote Management User Guide Rev 2.5 Page 2 of 12 Table of Contents Intended Audience...3 Remote Management...4 Remote Management Interface (RMI)...5 Accessing My Account... 5 Device List Page...
More informationRADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04
RADview-EMS/TDM Element Management System for TDM Applications Optimux-1553 1994 2004 RAD Data Communications Publication 07/04 Contents Chapter 1. Introduction 1.1 Overview... 1-1 1.2 System Features...
More informationSection 5. Control Systems
Section 5 There are several Kaleidescape options available for controlling a Premier system. Kaleidescape Remote Kaleidescape App for ipad Kaleidescape Child Remote Browser interface control panels A Premiere
More informationLaptop / PC Programming Manual
Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup
More informationTech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)
Tech Data Sheet D01662GB1_Esgraf 4.1 and Configuration Server 30/2011 1/(5) Esgraf 4.1 graphical user interface, configuration server and fire detectors contamination monitoring Esgraf 4.1 ESGRAF is a
More informationPhilips Intellivue Information Center Configuration
Philips Intellivue Information Center Configuration This page describes the Phillips IIC and Vocera Alarm Notification adapter configuration for a Vocera Communications EMDAN product implementation. Philips
More informationCode Alert Series 30 Software User Guide
Code Alert Series 30 Software User Guide 2018 RF Technologies, Inc. All specifications subject to change without notice. All Rights Reserved. No Part of this work may be reproduced or copied in any form
More informationCompleteView SightLogix Sensor Setup Manual. CompleteView Version 4.7.1
CompleteView SightLogix Sensor Setup Manual CompleteView Version 4.7.1 Table of Contents Contents Introduction... 3 Setup the SightLogix Sensor s Video in CompleteView... 4 Configuring the SightLogix Sensor
More informationSimpleComTools, LLC 1
COM1000-SNMP s Simple Network Management Protocol (SNMP) is a popular network management tool. Traditionally, SNMP was designed and used to gather statistics for network management and capacity planning.
More informationBOSCH GV4 Alarm Panel
System Galaxy Quick Guide CONFIGURATION AND OPERATION BOSCH GV4 Alarm Panel SG 10.2 (or later) NOV 2012 This is a Galaxy Product Interface Guide. Information in this document is subject to change without
More informationTable of Contents. i-vu CCN Standard 4.2
i-vu CCN Standard 4.2 Owner's Guide CARRIER CORPORATION 2009 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-381-01 7/13/2009 Table of Contents Accessing your
More informationArchestrA Direct Connect
Table of Contents ArchestrA Direct Connect... 1 Introduction... 1 ArchestrA Direct Connection... 1 ArchestrA Data Source Definition... 2 Data Source Definition... 2 Importing Alarms from ArchestrA... 6
More informationIDoorBell Fon DP68 Quick Installation Guide
IDoorBell Fon DP68 Quick Installation Guide 1. Interface 1. Front Panel 2. Back Panel 2. Doorbell Installation Options and Rain Cover Mounting Note: For the best camera angle, position the camera around
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Picture Perfect 4 INT-PP4-A-Rev1 Copyright 2012 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation
More informationOpenTouch Notification Service solution
OpenTouch Notification Service solution Remote demo and self-training Lab Ed06 Contents 1 Introduction... 3 2 Set up the simulation environment... 3 2.1. RDP... 3 2.2. OTNS... 4 2.3. Your Phone as simulation
More informationMonitor Alarms and Events
This chapter contains the following topics: What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Find and View Alarms, page 3 Set Alarm and Event Management Preferences,
More informationManual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel
Manual# 1006494 User s Manual 200E Series DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel User's Manual Rev. 1.0 Marine Pro 200E Series ~~~ DCU 210E Diesel Engine Control Unit DCU 208E Diesel
More informationAvigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1
Avigilon Control Center 5 System Integration Guide with STENTOFON AlphaCom INT-STENTOFON-C-Rev1 2013 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted
More informationCODE ALERT Enterprise Software User Guide
CODE ALERT Enterprise Software User Guide 2018 RF Technologies, Inc. All specifications subject to change without notice. All Rights Reserved. No Part of this work may be reproduced or copied in any form
More informationChapter. Configuring Cisco VSMS. Versions 5.1, 6.0. Configuring Third-Party Programs. SightLogix, Inc
Versions 5.1, 6.0 2 Chapter Configuring Third-Party Programs SightLogix devices are used with two types of third-party programs: VMS programs, which display video, GPS coordinates, and alarm and other
More informationModel 135 Reference Document
Model 135 Reference Document 2007 by Gordon Kapes, Inc. all rights reserved 5520 West Touhy Avenue Skokie, Illinois 60077 USA Telephone 847 676-1750 Fax 847 982-0747 www.gkinc.com 40218, Issue 1 January
More informationRE6100 Series Helix Security and Automation Platform
CONFIGURATION Resolution Compatibles RE6100 Series Helix Security and Automation Platform C G UI D E Configuration Settings Table 1 - Panel Settings Table 2 - Zone Settings Table 3 - Device Settings Table
More information1 Introduction Data transmission Compatibility IPS Analytics configuration... 3
Configuration Instruction Integration of IPS Video Analytics on Axis Cameras with a Milestone XProtect Video Management System Contents 1 Introduction... 1 2 Data transmission... 2 3 Compatibility... 3
More informationTechnical Notes Milestone Integration v3.0 January 17, 2017
TECHNICAL NOTES This document describes the setup and configuration of camera and lighting devices for Quantum Milestone Integration software version 2.0. Refer to the Milestone XProtect Management tool
More informationAlarm Gateway Object for Wonderware Application Server User Guide Ver 1.x Rev 1.4 PR 00185
Alarm Gateway Object for Wonderware Application Server User Guide Ver 1.x Rev 1.4 PR 00185 WONDERWARE FINLAND P.O. Box 38 FIN-00371 Helsinki Finland tel. int. + 358 9 5404940 fax int. + 358 9 5413541 www.wonderware.fi
More informationNovaStar 4X Pager Alarm Software 5073NS4X-AD DCN-M409
NovaStar 4X Pager Alarm Software 5073NS4X-AD DCN-M409 Receiving and Unpacking Carefully unpack all components and compare to packing list. Notify HydroLynx Systems immediately with any discrepancy. Inspect
More informationDTSX200 Communications(Modbus) Guide
User s Manual DTSX200 Communications(Modbus) Guide 4th Edition Blank Page < Introduction > i Introduction About this Manual Thank you for purchasing the DTSX200 Distributed Temperature Sensor. This document
More informationFortiNAC. Lightspeed Single Sign-On Integration. Version: 8.x Date: 8/29/2018. Rev: B
FortiNAC Lightspeed Single Sign-On Integration Version: 8.x Date: 8/29/2018 Rev: B FORTINET DOCUMENT LIBRARY http://docs.fortinet.com FORTINET VIDEO GUIDE http://video.fortinet.com FORTINET KNOWLEDGE BASE
More informationi-vu CCN 4.0 Owner s Guide
i-vu CCN 4.0 Owner s Guide CARRIER CORPORAION 2007 A member of the United echnologies Corporation family. Stock symbol UX. 11-808-377-01 07/07 able of Contents ACCESSING YOUR SYSEM... 3 YOUR SYSEM DEAILS...
More informationChapter. Configuring OnSSI NetDVMS. OnSSI NetDVMS versions 5.x through 6.5g. OnSSI NetDVMS Ocularis. Configuring Third-Party Programs
Configuring OnSSI NetDVMS OnSSI NetDVMS versions 5.x through 6.5g OnSSI NetDVMS Ocularis 2 Chapter Configuring Third-Party Programs SightLogix devices are used with two types of third-party programs: VMS
More informationAvigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0
Avigilon System Integration Guide Avigilon Control Center with AMAG Symmetry Security Management System 7.0 2013-2016, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, HDSM, HIGH
More informationWeekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT
Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT-1201739 Release 1.2 Issued Date July 30, 2004 Supersedes Document Introduction.................................................
More informationFirst day: SmartLink Web and SmartPager SmartLink and SmartPager installation Second day: SmartLink and SmartPager Configuration Alarms Management
First day: SmartLink Web and SmartPager SmartLink and SmartPager installation Second day: SmartLink and SmartPager Configuration Alarms Management Trace Log and FAQ Lorenzo Marino Software Engineer in
More informationUsing ANM Mobile CHAPTER
CHAPTER 19 Date: 3/22/13 This chapter describes Cisco ANM Mobile, which allows you to access your ANM server or ANM Virtual Appliance and manage your devices using a mobile device such as an iphone or
More informationMilestone SMI Intrepid II Perimeter Module 1.1 User s Manual
Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Target Audience for this Document This document is aimed at system users and provides descriptions on how to install and maintain the Milestone
More informationAvigilon Control Center 5 System Integration Guide
Avigilon Control Center 5 System Integration Guide with Lenel Facility Commander Wnx INT-FCWNX-A-Rev1 2010 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license
More informationMonitor Alarms and Events
What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Which Events Are Supported?, page 5 Set Alarm and Event Management Preferences, page 5 Interpret Event and Alarm
More informationProliphix. NT10e & NT20e. Configuration Guide
Proliphix NT10e & NT20e Configuration Guide Rev 2.5 Page i of iii TABLE OF CONTENTS INTRODUCTION...5 THERMOSTAT MANAGEMENT INTERFACE (TMI) AUTHENTICATION...5 QUICK SETUP...5 IP Addressability...5 Real
More informationRoom Alert. Room Alert 32E/W, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual
Room Alert Temperature & Environment Monitoring... Made Easy! Room Alert 32E/W, 12E, 4E & 3E Phone 401.628.1600 Fax 401.628.1601 Web AVTECH.com User s Guide & Reference Manual AVT-151105-01 Contact Us
More informationTech Note 836 Configuring an Alarm Acknowledgement Signature and Using the SignedAlarmAck() Script Function
Tech Note 836 Configuring an Alarm Acknowledgement Signature and Using the SignedAlarmAck() Script Function All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty
More informationRosenberger Intergrated Operation and Maintenance Center for all repeaters(2g/3g/lte) following CMCC and TMN specification.
Rosenberger Intergrated Operation and Maintenance Center for all repeaters(2g/3g/lte) following CMCC and TMN specification. Main Features The topology relationship of all repeater is shown by the domain
More informationAK SM 800 Commissioning Guide
AK SM 800 Commissioning Guide AK-SM 800 step-by-step ADAP-KOOL Oy Danfoss Ab / Kylmäosasto 1 Intro... 3 Connection to the system... 5 Software version... 7 Preferences wizard... 8 Users wizard... 10 Alarm
More informationControl System Studio - CSS - Alarm Handling
Control System Studio - CSS - Alarm Handling Kay Kasemir, Ph.D. ORNL/SNS kasemirk@ornl.gov June 2011 at KEK Managed by UT-Battelle Previous Attempts at SNS ALH; manual summary displays; generated soft-iocs
More informationRoom Alert. Room Alert 32E, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual
Room Alert Temperature & Environment Monitoring... Made Easy! Room Alert 32E, 12E, 4E & 3E Phone 401.628.1600 Fax 401.628.1601 Web AVTECH.com User s Guide & Reference Manual AVT-171212-1.1.0 Contact Us
More informationTOUCH PANEL INSTRUCTION MANUAL
TOUCH PANEL INSTRUCTION MANUAL OVERVIEW This manual includes information for use of Touch Panel. Please read this manual carefully before using the program. In case those information are ignored, please
More informationClareVision Plus Camera and Doorbell Creston Module Integration Notes
ClareVision Plus Camera and Doorbell Creston Module Integration Notes Content Introduction...1 Connecting to ClareVision Plus...1 Using events with Crestron...3 Contact information...5 Last modified: 01/22/18
More informationAdvisor Advanced Mobile Application User Manual
Advisor Advanced Mobile Application User Manual Content Warnings and Disclaimers 2 Advanced Mobile 2 Contact information 2 Description 2 Screen navigation 4 Gestures 4 Menu 4 Help navigation 4 Login 5
More informationMODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM
BTECH, Inc. 10 Astro Place Rockaway, NJ 07866 MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM Users Guide Rev 1.6 09OCT15 1.0 Description This feature of the S5 allows a plant computer (DCS) to monitor
More informationIndigoVision. Gallagher Integration Module. Administrator's Guide
IndigoVision Gallagher Integration Module Administrator's Guide Gallagher - Integration Module THIS MANUAL WAS CREATED ON THURSDAY, MARCH 22, 2018. DOCUMENT ID: IU-IM-MAN008-6 Legal Considerations LAWS
More informationInstallation, Configuration and User Manual
Model 8826 System Controller Model 8826 System Controller Installation, Configuration and User Manual READ AND SAVE THESE INSTRUCTIONS WELCOME Thank you for choosing the Aprilaire HVAC Automation System.
More informationPUMPS COMPATIBLE WITH ANY TYPE OF WATER PUMPING SYSTEM. Instructions must remain with installation.
450455 PUMPS Instructions must remain with installation. 2016 BURCAM Printed in Canada 450456T.2 ALERTS YOU before any water damage occurs from your sump or sewage tank IMPORTANT : Your Wi-Fi Water Watcher
More informationRMS Monitoring Software System Startup
System Startup 2017 ROTRONIC AG Bassersdorf Switzerland 2017 ROTRONIC AG Bassersdorf Switzerland Page 2 of 53 Contents Contents... 3 1 Overview... 5 1.1 System Requirements... 5 1.1.1 Browser... 5 2 Create
More informationAlarms for the Cisco ISA 3000
About s This chapter gives an overview of the alarm system in the ISA 3000, and also describes how to configure and monitor alarms. About s, on page 1 Defaults for s, on page 3 Configure s, on page 3 Monitoring
More informationIndigoVision. GAI-Tronics Integration Module. Administrator's Guide
IndigoVision GAI-Tronics Integration Module Administrator's Guide GAI-Tronics Integration Module THIS MANUAL WAS CREATED ON 10 APRIL 2013. DOCUMENT ID: IU-IM-MAN019-1 Legal Considerations LAWS THAT CAN
More informationAlarm Extension Pack for Wonderware Application Server Demo Guide Ver 1.0 Rev 1.0
Alarm Extension Pack for Wonderware Application Server Demo Guide Ver 1.0 Rev 1.0 WONDERWARE FINLAND P.O. Box 38 FIN-00371 Helsinki Finland tel. int. + 358 9 5404940 fax int. + 358 9 5413541 www.klinkmann.com
More informationOperation Manual Fighter ProVision Software. Version: 0.0 Revision: 1
Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User
More informationAdded password for IP setup page : Password must be in IP format!
NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP
More informationAUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12
AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual RST-5000 Series Web Enabled Input Module Rev. A2, 1/12 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com RST-5000
More informationInstruction Manual Environmental Monitoring Unit with Output Relay
Instruction Manual Environmental Monitoring Unit with Output Relay Watchdog 100 Series Firmware Version 3 Geist. 1821 Yolande Ave., Lincoln, NE 68521 800.432.3219 402.474.3400 F: 402.474.4369 www.geistglobal.com
More informationSensor Cloud User Manual
Sensor Cloud User Manual Table of Contents DEVICES TAB 4 1. DEVICE LIST 4 2. EXPAND ALL 4 3. EXPAND 4 4. STATUS 4 5. DEVICE 4 6. NAME 5 7. MONITORING INTERVAL 5 8. LAST ACTIVITY 5 9. VIEW 5 10. DELETE
More informationPotterNet Fire & Facility Supervising Station
Features Connect up to 1000 Potter panels in a single building, local campus, or multiple sites worldwide using LAN/WAN/Internet Native Ethernet networking connectivity with fire panels and client stations,
More information3D_ISS. Integrated Software System. User Guide Manual
3D Digital Design & Development LTD 58/60 Edward Road Tribec House New Barnet EN4 8AZ 020 8440 7060 3D_ISS Integrated Software System User Guide Manual Copyright 2014 3D Digital Design and Development
More informationFieldServer Driver - Serial FS SBT-FSI (Siemens Building Technologies Foreign Systems Interface)
Driver Version: 1.06 Document Revision: 4 Description FieldServer Driver - Serial FS-8700-40 SBT-FSI (Siemens Building Technologies Foreign Systems Interface) This FieldServer driver can be used to poll
More informationWeekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture
Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture Code No. LIT-1201743 Release 1.2 Issued Date July 30, 2004 Supersedes Document Introduction.................................................
More informationFCD-wire Contents. List of Figures
FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface
More informationP2267 NETWORK INTERFACE
P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61
More informationInstruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual
Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...
More informationION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document
70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,
More informationFiRe mobile-2 Operation Manual
FiRe mobile-2 Operation Manual P/N 00-3230-505-0003-01 ISS 07JAN15 Copyright Trademarks and patents Manufacturer Version 2015 UTC Fire & Security. All rights reserved. The FiRe mobile-2 name and logo are
More informationTrident User s Manual
Labkotec Oy Myllyhaantie 6 33960 Pirkkala FINLAND Tel. +358 (0)29 006 260 18.05.2017 Fax +358 (0)29 006 1260 Internet: www.labkotec.fi 34 pages Trident Copyright 2017 Labkotec Oy 1/34 TABLE OF CONTENTS
More informationHalton SAFE / 7.14 user guide and installation instructions
Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change
More informationContents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway
Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors 1 Set Up After downloading the Weatherhub app, follow these steps: 1.1 Connect the Gateway Connect
More informationBatt-Safe Battery String Monitoring System
Batt-Safe Battery String Monitoring System Technical White Paper October 2010 Introduction Battery monitoring systems are categorized as either cell monitors or string monitors. Battery cell monitors provide
More informationOperating instructions MEW01643 Revision -
Operating instructions MEW01643 Revision - EBLWeb V2.0.X for Web-server II, 1598 Author: Jonas Tsang Date of issue: 2013-09-13 Date of rev: Table of contents 1 Introduction 4 2 Definitions / Explanations
More informationModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.
ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page
More informationAlarm setup and definitions in Cisco Unified Serviceability
Alarm setup and definitions in Cisco Unified Serviceability Set up Cisco Unified IM and Presence Serviceability alarms, page 1 Alarm setup and update for a service, page 2 Alarm definitions and user-defined
More informationHikCentral Web Client. User Manual
HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.
More informationSamsung SDS BMS Ver.2.0. Technical Specification
Samsung SDS BMS Ver.2.0 Technical Specification Technical Specifications All rights and title, including all intellectual property rights to Samsung SDS BMS" is retained by Samsung SDS Co, Ltd. ("SDS"),
More informationOntech GSM 9040/50. Reference Manual English -1 -
Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7
More information