1 F U L L - L I N E P R O D U C T G U I D E Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

2 At System Sensor, innovation is more than an ideal; innovation is our way of life. Every day we design new products that are convenient to install and efficient to operate, providing our customers with the highest level of reliability. In other words, we make it our business to develop advanced ideas that deliver advanced solutions. This product guide is divided into four areas: Conventional Detection a complete line of smoke detectors led by the innovative i 3 Series. Audible/Visible Notification the SpectrAlert Advance line, the industry s newest, most refined series of notification devices. HVAC Systems Monitoring the Innovair line and other specialty detectors designed to detect smoke in air duct networks. Sprinkler Systems Monitoring products designed to sense the flow of water through pipes, switches and valves. Conventional Detection i 3 Series Photoelectric Smoke Detectors Installation ease, intelligence and instant inspection are the guiding principles of the System Sensor i 3 Series photoelectric smoke detectors. The i 3 Series is a complete line standard, sounder, auxiliary Form C relay and isolated thermal models featuring plug-in bases, removable covers, remote maintenance signaling, drift compensation and smoothing algorithms, green and red LEDs, and simplified sensitivity measurement. Loop Type Thermal Sounder Form C Relay Operating Voltage Avg. Standby Current Max. Alarm Current 2W-B 2-wire No No No VDC 50 µa 130 ma limited by control panel 2WT-B 2-wire Yes No No VDC 50 µa 130 ma limited by control panel 4W-B 4-wire No No No VDC 50 µa 23 ma 4WT-B 4-wire Yes No No VDC 50 µa 23 ma 2WTA-B 2-wire Yes Yes No VDC 50 µa 130 ma* 2WTR-B 2-wire Yes No Yes VDC 50 µa 130 ma limited by control panel 4WTA-B 4-wire Yes Yes No VDC 50 µa 35 ma 4WTR-B 4-wire Yes No Yes VDC 50 µa 35 ma 4WTAR-B 4-wire Yes Yes Yes VDC 50 µa 50 ma 4WITAR-B 4-wire Isolated Yes Yes VDC 50 µa 50 ma * In direct power (non-reverse polarity), the maximum alarm current is 130 ma limited by the panel. In reverse polarity power, the maximum current is 30 ma for the 2WTA-B in alarm; 12 ma for all other 2WTA-B units on the loop. Add 25 ma for the RRS-MOD reversing relay alarm current. 100 Series Plug-in Smoke Detectors The 100 Series low profile plug-in smoke detectors are ideal for light commercial applications. Offered with a photoelectric sensor, the 100 Series units may be installed with a range of plug-in bases to accommodate a variety of wiring configurations and voltages. Detection Type Wiring Thermal Operating Voltage Avg. Standby Current Max. Alarm Current 2151 Photoelectric Mounting base dependent No See bases 85 µa Mounting base dependent 2151T Photoelectric Mounting base dependent Yes See bases 85 µa Mounting base dependent 1

3 400 Series Plug-in Electronic Heat Detectors The 400 Series plug-in electronic heat detector offers thermal detection in a 135 F combination fixed/ rate-of-rise configuration. The 5451 detector may be installed with a range of 400 Series plug-in bases. Temperature Rating Activation Method Max. Standby Current degrees F Fixed/Rate-of-rise 100 µa 100 Series Plug-in Smoke Detector Bases The 100 Series bases are designed for use with the System Sensor 100 Series plug-in smoke detectors and accommodate 2- or 4-wire loops and 12, 24 or 120 operating voltages to address a broad range of applications. Loop Type Operating Voltage Alarm Current B110LP 2-wire 12/24 VDC ma limited by the control panel B110RLP 2-wire 24 VDC ma B112LP 4-wire 24 VDC ma B114LP 4-wire 120 VAC 75 ma (AC) maximum B116LP 2-wire 24 VDC ma limited by the control panel 400 Series Plug-in Smoke Detector Bases The 400 Series bases are designed for use with System Sensor 400 Series and 100 Series plug-in smoke detectors and are offered in a variety of models for 2- or 4-wire loops and 12, 24 or 120 operating voltages. Loop Type Alarm Contact Type Operating Voltage Max. Alarm Current B401 2-wire 12/24 VDC ma limited by the control panel B401B 2-wire 12/24 VDC ma limited by the control panel B401BR 2-wire 24 VDC ma B402B 4-wire Form A & C 24 VDC ma B404B 4-wire Form A & C + A supervisory 120 VAC 75 ma (AC) maximum B406B 2-wire Form C 24 VDC ma limited by the control panel CO1224T Carbon Monoxide Detector The CO1224T detector with RealTest is the industry s first carbon monoxide detector specifically designed for system connection. It is designed to maximize profits and minimize installation costs with code compliant features such as a trouble relay that sends a sensor failure or end-of-life signal to the control panel, and SEMS type terminal Philips-head screws that provide a quick and positive wiring connection while facilitating wiring supervision. The CO1224T unit also features a low current draw, which allows more detectors to be connected to the panel without having to purchase a more expensive panel or extra power supply. 2 Detection Type Wiring Operating Voltage Max. Standby Current CO1224T Electrochemical 4-wire 12/24 VDC 20mA 40mA Max. Alarm Current

4 5600 Series Mechanical Heat Detectors The 5600 Series mechanical heat detectors offer a low-cost means to protect property against fire and for non-life-safety installations where smoke detectors are inappropriate. To accommodate a broad range of applications, the 5600 Series units are available in a full line of configurations. Singleand dual-circuit models are available with low or high temperature ratings and with fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. Circuit Identification Method on Exterior Temperature Rating Activation Method Reflected Beam Smoke Detector The BEAM1224 Series reflected beam smoke detectors are equipped with both a transmitter and a receiver in one unit. They are easy to install and align with the included reflector. The BEAM1224S model comes with an integral sensitivity test feature. With six sensitivity levels, the BEAM1224 unit can be set to respond accurately in its respective environment. Plus, with multiple accessories ranging from multi-mounting to device heating, the BEAM1224 detector is capable of protecting any high ceiling area. Wiring Operating Voltage Avg. Standby Current Avg. Alarm Current Range Protected Spacing** 5601P Single Non-lettered 135 F (57 C) Fixed/Rate-of-rise 50 feet by 50 feet 5602 Single Lettering 194 F (90 C) Fixed/Rate-of-rise 50 feet by 50 feet 5603 Single Lettering 135 F (57 C) Fixed temperature 25 feet by 25 feet 5604 Single Lettering 194 F (90 C) Fixed temperature 25 feet by 25 feet 5621 Dual Lettering 135 F (57 C) Fixed/Rate-of-rise 50 feet by 50 feet 5622 Dual Lettering 194 F (90 C) Fixed/Rate-of-rise 50 feet by 50 feet 5623 Dual Lettering 135 F (57 C) Fixed temperature 25 feet by 25 feet 5624 Dual Lettering 194 F (90 C) Fixed temperature 25 feet by 25 feet **Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. BEAM wire VDC 17 ma 24 VDC 38.5 ma 24 VDC ft. (5m to 100m) BEAM1224S 4-wire VDC 17 ma 24 VDC 38.5 ma 24 VDC ft. (5m to 100m) Multi-Voltage Conventional Relays The System Sensor multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of building system interfacing. Description Operating Voltage Operating Current Contact Ratings PR-1 PR-2 PR-3 R-10T R-14T R-20T R-24T R-10E R-14E R-20E R-24E Epoxy encapsulated (SPDT) relay with an activation LED Epoxy encapsulated (SPDT) relay with an activation LED Epoxy encapsulated (SPDT) relay with an activation LED Single (SPDT) relay with an activation LED 4-gang (SPDT) relay with 4 activation LEDs Single (DPDT) relay with an activation LED 4-gang (DPDT) relay with 4 activation LEDs Single (SPDT) relay with an activation LED and steel enclosure 4-gang (SPDT) relay with 4 activation LEDs and steel enclosure Single (DPDT) relay with an activation LED and steel enclosure 4-gang (DPDT) relay with 4 activation LEDs and steel enclosure 120 VAC 15 ma DC 24 VDC, 24 VAC, 120 VAC 24 VDC: 7 A with L/R = 5 ms; 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive; 30 VDC: 10 A resistive VDC 30 ma DC max. 120 VAC: 10 A max. (resistive load); 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load); 30 VDC: 10 A max. (resistive load) VDC 30 ma DC max. 120 VAC: 10 A max. (resistive load); 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load); 30 VDC: 10 A max. (resistive load) 20 ma DC 24 VDC, 20 ma DC 24 VDC, 40 ma DC 24 VDC, 40 ma DC 24 VDC, 20 ma DC 24 VDC, 20 ma DC 24 VDC, 40 ma DC 24 VDC, 40 ma DC 24 VDC, 3

5 Conventional Detection Accessories Complementing the line of System Sensor detection products is a host of accessories designed to enhance installation, testing, operation, and maintenance. SENS-RDR RRS-MOD 2W-MOD2 RT A77-AB2 XR2B A77-AB RMK400 SMB600 MOD400R EOLR-1 APA151 BEAMLRK BEAMMMK BEAMSMK BEAMHK BEAMHKR RA400Z RTS451 RTS451KEY Description i 3 series infrared sensitivity reader i 3 series reversing relay / synchronization module i 3 series loop test and maintenance module i 3 series removal/replacement tool i 3 series retrofit adapter bracket 100 series installation/removal tool 100 series retrofit adapter bracket 100/400 series recessed mounting kit 100/400 series surface mount kit 100/400 series field sensitivity test module End of line power supervision relay Remote annunciator with piezo alarm Long-range kit for BEAM1224/BEAM1224S Multi-mount kit for BEAM1224/BEAM1224S Surface-mount kit for BEAM1224/BEAM1224S Heater kit for transmitter/receiver unit Heater kit for reflector Remote annunciator for spot and duct smoke detectors Remote test station accessory Remote test station accessory with key SENS-RDR MOD400R 2W-MOD2 APA151 RTS451KEY Audible/Visible Notification SpectrAlert Advance Wall-Mount Strobes The SpectrAlert Advance wall-mount strobe features a universal mounting plate with plug-in design, 11 field-selectable candela settings, and dual voltage in one device. The amber lens strobes provide the distinctive visual signal used for mass notification during non-fire evacuations. SpectrAlert Advance strobes are listed to UL SW-ALERT and SWH-ALERT amber lens strobes are listed to UL Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. SR SR-P* SR-SP* SRK SRK-R* SRK-P SRH SRH-P* SRHK SRHK-R* SRHK-P SW SW-P* SW-ALERT** SWK SWK-P SWH SWH-P* SWH-ALERT** SWHK SWHK-P Standard High UL Max. Strobe Current Draw (ma RMS) DC FWR DC FWR / NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA * For all SpectrAlert Advance models, a -P suffix denotes plain housing (no FIRE print); -SP denotes FUEGO printed housing. Outdoor units with model numbers ending with -R do not include weatherproof back boxes. Outdoor units with model numbers ending in K do include weatherproof back boxes. ** UL 1971 is not applicable to mass notification devices. Listed candela rating is per UL 1638 on-axis rating. 4

6 SpectrAlert Advance Wall-Mount Horn Strobes The SpectrAlert Advance wall-mount horn strobe is rich with features guaranteed to deliver cost-efficient installation time. Features include universal mounting plate with plug-in design, 11 field selectable candela settings, dual voltage in one product, and rotary switch selectable horn tone and volume settings. SpectrAlert Advance horn strobes are listed to UL 1971 and UL 464. Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. P2R P2R-P* P2R-SP* P2RK P2RK-R* P2RK-P P2RH P2RHK P2RHK-R* P2RHK-P P2RHK-120 UL Max. Current Draw (ma RMS), 2-wire Horn Strobe, Standard Range ( cd) V V DC Input 15 15/ / Temporal High Temporal Medium Temporal Low Non-temporal High P2W P2W-P* Non-temporal Medium Non-temporal Low FWR Input P2WK Temporal High Temporal Medium Temporal Low Non-temporal High Non-temporal Medium Non-temporal Low UL Max. Current Draw (ma RMS), 2-wire Horn Strobe, High Range ( cd) Volts Volts DC Input FWR Input P2WH Temporal High Temporal High P2WH-P* Temporal Medium Temporal Medium Temporal Low Temporal Low P2WHK Non-temporal High Non-temporal High Non-temporal Medium Non-temporal Medium Non-temporal Low Non-temporal Low Description, outdoor, high-candela horn strobe with integral 120V adapter; includes outdoor backbox To calculate current draw for 4-wire horn strobes, add the required strobe current and horn current from the tables below: P4R P4RK P4RK-R* P4RH P4W P4WK P4WHK Standard High UL Max. Strobe Current Draw (ma RMS) DC FWR DC FWR / NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA UL Max. Horn Current Draw (ma RMS) Sound Pattern db DC FWR DC FWR Temporal High Temporal Medium Temporal Low Non-temporal High Non-temporal Medium Non-temporal Low Coded High Coded Medium Coded Low * For all SpectrAlert Advance models, a -P suffix denotes plain housing (no FIRE print); -SP denotes FUEGO printed housing. Outdoor units with model numbers ending with -R do not include weatherproof back boxes. Outdoor units with model numbers ending in K do include weatherproof back boxes. 5

7 SpectrAlert Advance Mini-Horns The SpectrAlert Advance series of mini-horn sounders are designed to provide primary and secondary signaling for fire and security applications. They include two volume settings, 12- or 24-volt operation and are compatible with the System Sensor synchronization protocol. MHR MHW Sound Pattern Volume Sounder Current Draw (ma RMS) DC FWR DC FWR Temporal High Temporal Low Non-temporal High Non-temporal Low SpectrAlert Advance Horns The SpectrAlert Advance horn includes a universal mounting plate with plug-in design, three volume settings, and a rotary switch used for horn tone selection. SpectrAlert Advance horns are listed to UL 464. Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. HR HRK HKR-R* HW UL Max. Horn Current Draw (ma RMS) Sound Pattern db DC FWR DC FWR Temporal High Temporal Medium Temporal Low Non-temporal High Non-temporal Medium Non-temporal Low Coded High Coded Medium Coded Low * All outdoor units ending in K include weatherproof back box except those with a -R suffix SpectrAlert Advance Chimes The SpectrAlert Advance chimes feature rotary switch selectable horn tone and volume settings and are compatible with the System Sensor synchronization protocol. Intended for private mode applications, the chime meets UL 464. CHR CHW UL Max. Chime Current Draw (ma RMS) Sound Pattern db DC FWR DC FWR 1 Second Chime High Second Chime Low ¼ Second Chime High ¼ Second Chime Low Temporal Chime High Temporal Chime Low Second Whoop High Second Whoop Low Coded High * *This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. 6

8 SpectrAlert Advance Chime/Strobes The SpectrAlert Advance chime/strobes feature a plug-in design, seven field-selectable candela settings, and dual voltage in one device. Intended for private mode application, the chime/strobe meets UL CHSR CHSW UL Max. Chime/Strobe Current Draw (ma RMS) DC Input 15 15/ / Second Chime High Second Chime Low /4 Second Chime High /4 Second Chime Low Temporal Chime High Temporal Chime Low Second Whoop High Second Whoop Low One Time Chime* FWR Input 15 15/ / Second Chime High Second Chime Low /4 Second Chime High /4 Second Chime Low Temporal Chime High Temporal Chime Low Second Whoop High Second Whoop Low One Time Chime* *Chime/strobes cannot be powered with a coded supply. SpectrAlert Advance Ceiling-Mount Strobes The SpectrAlert Advance ceiling-mount strobes feature a universal mounting plate with preliminary snap-in feature to hold the product in place for the screw attachment, 11 field-selectable candela settings, and dual voltage in one device. SpectrAlert Advance strobes are listed to UL Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. SCR SCRK SCRK-R* SCRH SCRHK SCRHK-R* SCW SCW-P* SCWK SCWH SCWHK Standard High UL Max. Strobe Current Draw (ma RMS) DC FWR DC FWR / NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA * For all SpectrAlert Advance models, a -P suffix denotes plain housing (no FIRE print); -SP denotes FUEGO printed housing. Outdoor units with model numbers ending with -R do not include weatherproof back boxes. Outdoor units with model numbers ending in K do include weatherproof back boxes. 7

9 SpectrAlert Advance Ceiling-Mount Horn Strobes The SpectrAlert Advance ceiling-mount horn strobes are rich with features guaranteed to cut installation time and maximize profits. Features include a universal mounting plate with a preliminary snap-in feature to hold the product in place for the screw attachment, 11 fieldselectable candela settings, dual voltage in one product, and rotary switch selectable horn tone and volume settings. SpectrAlert Advance horn strobes are listed to UL 1971 and UL 464. Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. PC2R PC2R-P* PC2RK PC2RK-R* PC2RH PC2RHK PC2RHK-R* PC2W PC2W-P* PC2W-SP* PC2WK PC2WH PC2WH-P* PC2WHK UL Max. Current Draw (ma RMS), 2-wire Horn Strobe, Standard Range ( cd) V V DC Input 15 15/ / Temporal High Temporal Medium Temporal Low Non-temporal High Non-temporal Medium Non-temporal Low FWR Input Temporal High Temporal Medium Temporal Low Non-temporal High Non-temporal Medium Non-temporal Low UL Max. Current Draw (ma RMS), 2-wire Horn Strobe, High Range ( cd) Volts Volts DC Input FWR Input Temporal High Temporal High Temporal Medium Temporal Medium Temporal Low Temporal Low Non-temporal High Non-temporal High Non-temporal Medium Non-temporal Medium Non-temporal Low Non-temporal Low To calculate current draw for 4-wire horn strobes, add the required strobe current and horn current from the tables below: PC4R PC4RH PC4W PC4WK PC4WHK Standard High UL Max. Strobe Current Draw (ma RMS) DC FWR DC FWR / NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA UL Max. Horn Current Draw (ma RMS) Sound Pattern db DC FWR DC FWR Temporal High Temporal Medium Temporal Low Non-temporal High Non-temporal Medium Non-temporal Low Coded High Coded Medium Coded Low * For all SpectrAlert Advance models, a -P suffix denotes plain housing (no FIRE print); -SP denotes FUEGO printed housing. Outdoor units with model numbers ending with -R do not include weatherproof back boxes. Outdoor units with model numbers ending in K do include weatherproof back boxes. 8

10 SpectrAlert Advance Dual Voltage Evacuation Speakers The dual voltage (25/70.7 Vrms) evacuation speakers feature a plug-in design for reducing ground faults and allowing for fast installation. The low total harmonic distortion of the SP speaker offers high-fidelity sound output while the SPV speaker offers high-volume sound output for use in high-ambient-noise applications. The outdoor models ship with a plastic outdoor back box featuring removable side flanges and improved salt water corrosion resistance. Outdoor products are rated from 40 F to +151 F ( 40 C to +66 C) and have a NEMA 4X rating. SpectrAlert Advance speakers are listed to UL 1480 for fire protective signaling systems. SpectrAlert Advance Selectable Output Speaker Strobes The selectable output speaker strobes offer many features to reduce ground faults and make installation simple, including plug-in design with universal mounting plate, rotary switches for voltage and power settings, 11 field-selectable candela settings, and speakers for high fidelity or high volume. The outdoor models ship with the plastic outdoor back box and are rated from 40 F to +151 F ( 40 C to +66 C) for outdoor operation. SpectrAlert Advance selectable output speaker/ strobes are listed to UL 1971 and UL Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. SPSR SPSR-P* SPSRV SPSRV-P* SPSCR SPSCRV SPSRK SPSRK-R SPSRK-P SPSRH SPSRH-P* SPSCRH SPSCRVH UL Max. Strobe Current Draw (ma RMS) SPSW SPSW-P* SPSWV SPSWV-P* SPSCW SPSCW-P* SPSCWV SPSCWV-P* SPSWK SPSWK-R SPSWK-P SPSCWK SPSCWK-R SPSWH SPSWH-P* SPSCWH SPSCWH-P* SPSCWVH SPSCWVH-P* SPSCWHK SPSCWHK-R * For all SpectrAlert Advance models, a -P suffix denotes plain housing (no FIRE print). 8 to 17.5 Volts DC 8 to 17.5 Volts FWR 16 to 33 Volts DC 16 to 33 Volts FWR / N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SpectrAlert Advance Sync Circuit Module The SpectrAlert Advance Sync Circuit module is designed to simplify installations requiring signal synchronization. Average Current (ma) Peak Current (ma) In-rush Current (ma) Voltage DC FWR DC FWR DC FWR MDL MDLW Description SPR SPW Wall mount speaker SPRV SPWV Wall mount speaker, high db SPCR SPCW Ceiling mount speaker SPCRV SPCWV Ceiling mount speaker, high db SPRK, SPRK-R SPWK, SPWK-R Outdoor wall mount speaker SPCWK, SPCWK-R Outdoor ceiling mount speaker

11 SpectrAlert Advance Accessories SpectrAlert Advance devices can be adapted to nearly any application by selecting the appropriate accessory to meet the application need. Our mounting options allow our strobes, speakers, horns, chimes, and strobe combinations to be placed in new or existing construction with professional results. Description SPBBSC SPBBSCW Surface mount back box skirt for ceiling mount speaker strobe SPBBS SPBBSW Surface mount back box skirt for wall mount speaker strobe RFP RFPW Retrofit plate for SpectrAlert Advance devices BBS-2 BBSW-2 Surface mount back box skirt for wall mount horns, strobes, and horn strobes BBSC-2 BBSCW-2 Surface mount skirt for ceiling mount horns, strobes, and horn strobes SA-WBB Wall mount, metal outdoor back box for horns, strobes, and horn strobes SA-WBBC Ceiling mount, metal outdoor back box for horns, strobes, and horn strobes TR-HS TRW-HS Wall mount trim ring for SpectrAlert Advance horns, strobes, and horn strobes TRC-HS TRCW-HS Ceiling mount trim ring for SpectrAlert Advance horns, strobes, and horn strobes TR TRW Wall mount trim ring for SpectrAlert Advance speakers and speaker strobes TRC TRCW Ceiling mount trim ring for SpectrAlert Advance speakers and speaker strobes MWBB MWBBW Wall mount metal outdoor back box for speakers and speaker strobes MWBBCW Ceiling mount metal outdoor back box for speakers and speaker strobes MP120K Indoor/outdoor 120VAC adapter mounting plate for use with SpectrAlert Advance horns, strobes, horn strobes, chimes, and chime strobes Wall Ceiling Description LENS-A LENS-AC Amber lens attachment for SpectrAlert Advance non-fire (plain) indoor or outdoor strobe models LENS-B LENS-BC Blue lens attachment for SpectrAlert Advance non-fire (plain) indoor or outdoor strobe models LENS-G LENS-GC Green lens attachment for SpectrAlert Advance non-fire (plain) indoor or outdoor strobe models LENS-R LENS-RC lens attachment for SpectrAlert Advance non-fire (plain) indoor or outdoor strobe models HVAC Systems Monitoring During a fire, an HVAC system can circulate toxic gasses and smoke throughout a building unless that building is equipped with InnovairFlex duct smoke detectors. Overcome Mounting Constraints InnovairFlex housings can accommodate multiple installation footprints, including rectangular, square, and anything in between. uce Installation Time Sampling tubes can be installed from the front or back of the detector without the need for tools or hardware. Additional conduit openings, improved wiring space, and high-contrast terminal designations simplify the installation process further. Simplify Testing and Maintenance On 4-wire models an easy access test/reset button simplifies system testing, and Power, Trouble, Maintenance, and Alarm LEDs assure quick and convenient status checks. The cover missing trouble signal, now included on all models, assures system integrity. 10 Model Description Wiring D2 D4120 D4120W D4S Photoelectric low-flow duct smoke detector Photoelectric low-flow duct smoke detector Watertight photoelectric lowflow duct smoke detector Photoelectric low-flow sensor only component Air Velocity Range Operating Temp. Range 2-wire ft/min 4 to 158 F ( 20 to 70 C) 4-wire ft/min 4 to 158 F ( 20 to 70 C) 4-wire ft/min 4 to 158 F ( 20 to 70 C) 4-wire ft/min 4 to 158 F ( 20 to 70 C) D4P120 Power board only component 4-wire 4 to 158 F ( 20 to 70 C) 2151 Photoelectric no-flow/low-flow smoke detector 4-wire ft/min 32 to 120 F (0 to 49 C) Rating Operating Voltage Alarm Current 12/24 VDC 130 ma max 24 VAC/DC or 120 VAC 65 ma max at 24 VDC NEMA 4 24 VAC/DC or 120 VAC 65 ma max at 24 VDC 24 VAC/DC or 120 VAC 65 ma max at 24 VDC 24 VAC/VDC or 120 VAC 65 ma max at 24 VDC 24 VAC/DC w/b114lpbt base; 120 VAC w/b114lp base Auxiliary Contact 2 Form C Auxiliary 2 Form C Auxiliary 2 Form C Auxiliary 75 ma max 1 Form A & 1 Form C Auxiliary Relay

12 HVAC Accessories Model Description Operating Voltage SSK451 Multi-signaling accessory, remote test station with horn, allows local testing of a remote duct detector, for use with System Sensor D4120, DH100ACDC and DH400ACDC VDC APA151 Remote annunciator with piezo alert VDC RA400Z Remote annunciator for spot and duct smoke detectors VDC RTS451 Remote test station accessory VDC (Alarm LED) RTS451KEY Remote test station accessory with key reset VDC (Power LED); VDC (Alarm LED) RTC100 Remote test coil kit with low-profile ring (includes RTS451 remote test station) PS24LO(W) Mini-Alert add-on strobe for use with SSK451 or PA400W VDC DST1 DST1.5 DST3 DST5 DST10 ETX InnovairFlex sampling tube for ducts up to 1 foot InnovairFlex sampling tube for ducts 1 to 2 feet InnovairFlex sampling tube for ducts 2 to 4 feet InnovairFlex sampling tube for ducts 4 to 8 feet InnovairFlex sampling tube for ducts 8 to 12 feet InnovairFlex twelve-inch exhaust tube Sprinkler Systems Monitoring WFD Series Water Flow Detector The WFD Series water flow detectors are available in a range of sizes to accommodate fire sprinkler risers from two to eight inches. All units feature vane type paddles and an adjustable mechanical relay. Model Pipe Size Hole Size Pressure Rating Contact Ratings Triggering Threshold WFD /4 450 PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4 10 GPM WFD /2 1 1 /4 450 PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4 10 GPM WFD PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4 10 GPM WFD /2 1 1 /4 450 PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4 10 GPM WFD PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4 10 GPM WFD PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4 10 GPM WFD PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4 10 GPM WFD PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4 10 GPM T-Tap Series Water Flow Detector The T-Tap water flow detectors are compatible with one-inch NPT style connections, making them ideal for residential or branch line signaling applications. Model WFDT WFDTH WFDTNR Compatible Tee Fittings 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. Pressure Rating Contact Ratings 250 PSI 2 Form C: 125/250 VAC, 2.5 A 24 VDC 250 PSI 2 Form C: 125/250 VAC, 2.5 A 24 VDC 250 PSI 2 Form C: 125/250 VAC, 2.5 A 24 VDC Triggering Threshold 4 10 GPM 4 10 GPM 4 10 GPM 11

13 Supervisory Switches System Sensor manufactures devices for supervising a variety of control valves, including outside screw and yoke, post indicator, butterfly, and rising and non-rising stem gate. Model Description Valve Size Contact Rating OSY2 PIBV2 PSP1 Used to monitor the open position of an outside screw and yoke type gate valve Used to monitor the open position of post indicator and butterfly control valves A plug-in special application supervisory switch designed for applications where no other type of listed valve supervisory switch can be used 1 to /250 VAC; 2.5 6/12/24 VDC /250 VAC; 2.5 6/12/24 VDC Plug Contacts: 6/12/24 VAC/DC, normally open Cover Tamper: 125/250 VAC, 6/12/24 VAC Maximum Operating Current 250mA EPS Series Pressure Switches The EPS Series pressure switches are offered in three varieties and with one or two SPDT contacts. The EPS10 alarm pressure switches are ideal for dry pipe systems, while the EPS40 and EPS120 supervisory pressure switches are intended for supervising air pressure in pipes or pressure tanks. Model EPS10-1 EPS10-2 EPS40-1 EPS40-2 EPS120-1 EPS120-2 Maximum Operating Pressure Maximum Adjustment Range Differential Contact Rating 250 psi 4 to 20 psi 3 psi 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 250 psi 10 to 100 psi 3 10 psi and 6 psi at 100 psi 250 psi 10 to 200 psi 3 10 psi and 9 psi at 200 psi 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC Threaded Connection 1 /2 NPT male reinforced nylon 1 /2 NPT male reinforced nylon 1 /2 NPT male reinforced nylon Alarm Bells The alarm bells offer high output notification in security and fire alarm systems. Six-inch, eight-inch, and ten-inch models are available for 24 VDC and 120 VAC systems. Model Gong Size Nominal Voltage Operating Voltage Sound Output Maximum Current SSM VDC VDC 82 db DC 31.1 ma / FWR 53.5 ma SSM VDC VDC 80 db DC 31.1 ma / FWR 53.5 ma SSM VDC VDC 81 db DC 31.1 ma / FWR 53.5 ma SSV VAC VAC 85 db 53 ma SSV VAC VAC 82 db 53 ma SSV VAC VAC 82 db 53 ma 12

14 System Sensor is a global manufacturer of fire detection and notification devices, specializing in smoke detection and notification technology. System Sensor places a premium on research and development, resulting in products that are reliable, sophisticated, and designed for real-world applications. With sales, service, and manufacturing facilities throughout the Americas, Europe, and Asia, System Sensor s high quality, innovative products are the most comprehensive in the industry System Sensor. The company reserves the right to change specifications at any time. A /08 #2036

Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring F U L L - L I N E P R O D U C T G U I D E Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring At System Sensor, innovation is more

More information

The Advance You ve Been Looking For

The Advance You ve Been Looking For The Advance You ve Been Looking For The Power Behind The Products System Sensor was founded in 1984 and today is the largest manufacturer of fire detection and notification appliances in the world. More

More information

Fire Safety Product Catalog

Fire Safety Product Catalog Fire Safety Product Catalog Innovation is our way of life. At System Sensor, innovation is our way of life. Every day we design new products that are convenient to install and efficient to operate, providing

More information

Fire & Life Safety Products CATALOG

Fire & Life Safety Products CATALOG Fire & Life Safety Products CATALOG Audible/Visible Notification Beam Smoke Detection Carbon Monoxide Detection HVAC Duct Smoke Detection and Monitoring Smoke Detection Fire Sprinkler Systems Monitoring

More information

Bid Specifications. Fire Alarm Equipment and Parts. USA Bid No

Bid Specifications. Fire Alarm Equipment and Parts. USA Bid No Bid Specifications Fire Alarm Equipment and Parts USA Bid No. 4120302 Equivalent Mfr. Part No. Manufacturer Equivalent Item Description 21006374 Kidde Kidde Smoke Detector 50 21006371 Kidde Kidde Smoke

More information

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E SpectrAlert Advance Description System Sensor SpectrAlert Advance offers a variety of devices designed for mass notification, including plain devices for non-fire applications, amber lens strobes and speaker

More information

Reshaping Duct Smoke Detection

Reshaping Duct Smoke Detection Reshaping Duct Smoke Detection When System Sensor introduced the Innovair line of duct smoke detectors and accessories, it was revolutionary. Mechanical contractors and fire systems installers like you

More information

Manual Call Point-Installation efficiency, Flexibility and full compliance with latest standards are at the heart of new Indoor Call Point range.

Manual Call Point-Installation efficiency, Flexibility and full compliance with latest standards are at the heart of new Indoor Call Point range. At System Sensor, innovation is more than an ideal; innovation is our way of life. Every day we design new products that are convenient to install and efficient to operate, providing our customers with

More information

Reshaping Duct Smoke Detection

Reshaping Duct Smoke Detection Reshaping Duct Smoke Detection Y TE + TEST COIL TEST COIL + IN + OUT RA + RA + RTS (+) 24 VDC AUX POWER SUPPLIED BY USER (100mA SUPPLY) 24 VAC (+10%, 15%) FULL WAVE RECTIFIED, UNFILTERED POWER MAY BE USED

More information

Full Line Catalog and Product Brochures

Full Line Catalog and Product Brochures Welcome to E DOCS Electronic Documents on CD-ROM This disc contains Product s Product Installation s Agency Listings Applications Guides Full Line Catalog and Product Brochures click below to search by

More information

Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices. White Paper February 2014

Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices. White Paper February 2014 Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices White Paper February 2014 Designed to be watertight and to operate in a wide temperature range, SpectrAlert Advance

More information

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize advanced ideas advancedsolutions At System Sensor, Research and Development is more than a department. It s a way of life. Every day we work to design new products that utilize the most innovative technologies

More information

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors Carbon Monoxide (CO) Detection PRODUCTS Accessories Conventional Detectors 2 Complete CO Detection The system-connected CO1224T and CO1224TR CO detectors with RealTest provide early warning by using reliable

More information

Selectable Output Chimes and Chime/Strobes

Selectable Output Chimes and Chime/Strobes Selectable Output Chimes and Chime/Strobes PRELIMINARY DN-60940:A Audio/Visual Devices General System Sensor L-Series selectable-output chimes and chime/ strobes are rich with features guaranteed to cut

More information

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity Fire Sprinkler Monitoring Products Solutions and Service for Sprinkler System Integrity waterflow monitoring Monitoring Fire Sprinkler System Flow During a fire condition, sprinkler system reliability

More information

Control / Communicator

Control / Communicator ARMED READY A D S SPACE B E T R C F X ENTER MAX INSTANT READY R BYPASS FA2000C Control / Communicator BS/ESC N/Y SHIFT 1 4 5 6 7 8 9 0 2 # 3 ARMED READY FA560 A 1 OFF 2 AWAY 3 STAY B 4 5 TEST 6 C 7 8 CODE

More information

Lite-Configurator Version 3.1 Readme

Lite-Configurator Version 3.1 Readme Lite-Configurator Version 3.1 Readme 2007-2018 by Honeywell International, Inc. All Rights Reserved In this Release This Readme document contains release notes for Lite-Configurator Version 3.0. It includes

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer

More information

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL March 30, 2000 Section: Audio/Visual Devices G-250 SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL System Sensor SpectrAlert Series strobes, horns, and combination horn/strobes are UL listed

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Horns, Strobes and Horn Strobes for Wall Applications General The L-Series audible visible notification products

More information

AL602ULADA. NAC Power Extender. Installation Guide (see 02 Application Guide for additional information) More than just power. TM. Rev.

AL602ULADA. NAC Power Extender. Installation Guide (see 02 Application Guide for additional information) More than just power. TM. Rev. Altronix Corp. 140 58th St. Brooklyn, NY AL602ULADA NAC Power Extender Installation Guide (see 02 Application Guide for additional information) Rev. 042209 More than just power. TM Overview: Altronix AL602ULADA

More information

CO/Smoke Detection PRODUCTS. Accessories Conventional Detectors and Modules

CO/Smoke Detection PRODUCTS. Accessories Conventional Detectors and Modules CO/Smoke Detection PRODUCTS Accessories Conventional Detectors and Modules 2 4 Increase your sales, RMR and customer retention......by protecting your customers from fire and deadly CO gas. Did you know

More information

31566 Railroad Canyon Road STE 2 Canyon Lake, CA Office Fax

31566 Railroad Canyon Road STE 2 Canyon Lake, CA Office Fax Date 9-10-2016 Project: Field Elementary School Pasadena, CA FIRE ALARM SUBMITAL Devices Used DESCRIPTION MODEL MANUFACTURE CSFM SMOKE DETECTOR FSP-851 NOTIFIER 7272-0559;0129 HEAT DETECTOR FST-851H NOTIFIER

More information

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev Altronix Corp. 140 58th St. Brooklyn, NY AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 101413 AL1042ULADA NAC Power Extender Overview: The Altronix

More information

Agent Release Control Panel

Agent Release Control Panel Agent Release Control Panel System Capacity Annunciators: 8 Electrical Specifications RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps RP-2002E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps

More information

L-Series, Emergency Communication Devices

L-Series, Emergency Communication Devices Notification Appliances L-Series, Emergency Communication Devices Description The L-Series Emergency Communications devices and accessories combine application versatility with all of the same time-saving

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes L-Series Audible Visible Notification PRODUCTS Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes 2 Simple to install, yet powerful enough to meet any requirement.

More information

BPS NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

BPS NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev BPS-1002 NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 101413 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864). MEA

More information

Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS CONVENTIONAL PANEL W/ BUILT-IN DIGITAL ALARM COMMUNICATOR

Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS CONVENTIONAL PANEL W/ BUILT-IN DIGITAL ALARM COMMUNICATOR Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS 2-ZONE FIRE ALARM CONTROLS MS-2 Fire Alarm Control Panel, 2-Zone, Class B, 24VDC, One Class B $455.00 NAC MS-2E Export version of MS-2; 220 Volts $455.00

More information

SECTION FIRE ALARM SYSTEMS

SECTION FIRE ALARM SYSTEMS SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work

More information

MODEL Intelligent Power Module. Installation and Operations Manual. Document /12/10 Rev: E1 P/N :E1 ECN:

MODEL Intelligent Power Module. Installation and Operations Manual. Document /12/10 Rev: E1 P/N :E1 ECN: MODEL 5496 Intelligent Power Module Installation and Operations Manual Document 151276 08/12/10 Rev: E1 P/N 151276:E1 ECN: 10-484 Contents Section 1 Overview... 1-1 1.1 5496 Description... 1-1 1.2 Agency

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

WFDE Series Waterflow Detector

WFDE Series Waterflow Detector WFDE Series Waterflow Detector The System Sensor WFDE series is compatible with pipe diameters ranging from 50mm through 200mm and can be mounted in a vertical or horizontal position. Features Compliant

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

MODEL Distributed Power Module. Installation and Operations Manual. Part Number Rev L

MODEL Distributed Power Module. Installation and Operations Manual. Part Number Rev L MODEL 5495 Distributed Power Module Part Number 151161 Rev L Installation and Operations Manual Contents Section 1 Introduction...1 Section 2 UL Requirements...2 2.1 ULC Requirements...2 Section 3 System

More information

DH100ACDCI Ionization Air Duct Smoke Detector

DH100ACDCI Ionization Air Duct Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS Ionization Air Duct Smoke Detector Before Installing Please thoroughly read the System Sensor Guide for Proper Use of Smoke Detectors in Duct Applications (A05-1004),

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing UL, ULC Approved* TrueAlarm Analog Sensing TrueAlarm Analog Sensors Photoelectric and Heat; Standard Bases and Accessories Features TrueAlarm analog sensing provides: Digital transmission of analog sensor

More information

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range INSTALLATION AND MAINTENANCE INSTRUCTIONS TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range 825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 60-77-6495

More information

Vista-20SEUL System Design Sheet

Vista-20SEUL System Design Sheet System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO SECTION 1: Basic -Features QED programming for quick enrollment of devices (Eight Hardwired Zones, Wireless) Part

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

AL600ULX Series. Power Supply/Charger. Installation Guide

AL600ULX Series. Power Supply/Charger. Installation Guide AL600ULX Series Power Supply/Charger Installation Guide Models Include: AL600ULX - Single Output AL600ULPD4 AL600ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL600ULPD8 AL600ULPD8CB - Eight

More information

Vista-50P/-50PUL System Design Sheet

Vista-50P/-50PUL System Design Sheet Vista-50P/-50PUL System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-50P (Nine Hardwired Zones, One Addressable Loop, Wireless)

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Listed* TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone

More information

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range INSTALLATION AND MAINTENANCE INSTRUCTIONS Air Duct Smoke Detector with Extended Air Speed Range A Division of Pittway 825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 60-77-6495 The Innovair

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

DH100ACDCI Ionization Air Duct Smoke Detector

DH100ACDCI Ionization Air Duct Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS Ionization Air Duct Smoke Detector Before Installing Please thoroughly read the System Sensor Guide for Proper Use of Smoke Detectors in Duct Applications (A05-1004),

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

TrueAlert Notification Appliances

TrueAlert Notification Appliances TrueAlert Notification Appliances UL Listed; FM, CSFM and MEA (NYC) Approved* Non-Addressable Audible/Visible Notification Appliances with SmartSync Operation of Strobes and Horns Features Wall mount audible/visible

More information

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs AL300ULX Series Power Supply/Charger Installation Guide Models Include: AL300ULX - Single Output AL300ULPD4 AL300ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL300ULPD8 AL300ULPD8CB - Eight

More information

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1002ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

TrueAlarm ES Analog Sensing

TrueAlarm ES Analog Sensing TrueAlarm ES Analog Sensing UL, ULC, CSFM Listed; FM Approved* Features TrueAlarm addressable sensor base with 520 Hz sounder TrueAlarm sensor bases with 520 Hz tone require a TrueAlarm photoelectric,

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

Potter Wall Mount Select-A-Strobe

Potter Wall Mount Select-A-Strobe 104 Kenran Industrial Dr. Potter Wall Mount Select-A-Strobe SL-1224 SERIES SELECT-A-STROBE Call for additional listings 12 VDC with 15, 35 or 60 cd setting 24 VDC with 15, 35, 60, 5, 95 or 110 6 distinct

More information

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs AL400ULX Series Power Supply/Charger Installation Guide Models Include: AL400ULX - Single Output AL400ULPD4 AL400ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL400ULPD8 AL400ULPD8CB - Eight

More information

Multi-Point Peripherals

Multi-Point Peripherals UL, ULC Approved* Multi-Point Peripherals TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features Fig 1: TrueAlarm CO Sensor Base with Sounder (shown with

More information

Vista-128FB System Design Sheet

Vista-128FB System Design Sheet Vista-128FB System Design Sheet FIRE DETECTION SPRINKLER SUPERVISION INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-128FB (Eight Hardwired Zones,

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Life safety notification

Life safety notification LED Wheelock Exceder LED3 Life safety notification Meeting the latest codes with increased energy-efficiency in a compact design Wheelock Exceder LED3 Compliant, compatible, compact, and energy efficient

More information

Signature Series Auto-Sync Output Module (CC1S)

Signature Series Auto-Sync Output Module (CC1S) Signature Series Auto-Sync Output Module (CC1S) Product description Mounting The Signature Series can be mounted in a North American 2-1/2 in (64 mm) deep 2-gang box or a standard 4 in square box 1-1/2

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed for Control Units for Fire Protective Signaling Systems (UL

More information

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics by Tomar Electronics SIRENS POWER ALARM PROGRAMMABLE MULTI-SOUND INDUSTRIAL SIGNALS The POWER ALARM siren is a heavy duty industrial audible alarm designed to operate under adverse industrial conditions

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Multiple Input and Output Modules

Multiple Input and Output Modules Kingfisher Company, inc. Multiple Input and Output Modules Features: Removable 12 to 18 AWG plug-in terminal blocks Individual LED indicators Unused addresses may be disabled Rotary address switches Class

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

Silent Knight Device Compatibility

Silent Knight Device Compatibility Silent Knight Device Compatibility SK-5208 Conventional FACP SK-2 / SK-4 Conventional FACPs 5495 6A Conventional Distributed Power Supply 5496 6A Intelligent Distributed Power Supply 5499 9A Conventional

More information

SAFEPATH Mass Notification System (SPMNS)

SAFEPATH Mass Notification System (SPMNS) Supersedes February 2016 SAFEPATH Mass Notification System (SPMNS) SP40S SPB-320 SPB-80/4 SPB-160 PS-8-LP SPMNS-MIC SP4Z-A/B Contents Page SPMNS.... 2-4 SPMNS-MIC...3 Expansion Options SAFEPATH 2-zone

More information

Fire Alarm System Fundamentals

Fire Alarm System Fundamentals Fire Alarm System Fundamentals Mircom is the largest and oldest privately owned fire alarm and life safety manufacturer in North America and 5th largest overall with 50 years of industry experience. Mircom

More information

Multi-Point Peripherals

Multi-Point Peripherals Multi-Point Peripherals UL, ULC, CSFM Listed; FM Approved* TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features TrueAlarm addressable CO sensor bases contain

More information

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep. 140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC

More information

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information OF FIRE CS24C Colored Light Strobe/orn Series igh Candela Ceiling/Wall Mount Patent Pending Description AMSECO's UL listed Colored Light Strobe CS24C series is designed to provide audible and visual signals

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev Altronix Corp. 140 58th St. Brooklyn, NY AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 052313 Agency Listings: UL Listed for Control Units for

More information

Vista-10SE System Design Sheet

Vista-10SE System Design Sheet Vista-10SE System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO SECTION 1: Basic Vista-10SE -Features QED programming for quick enrollment of devices Part No. Qty. Each

More information

SAFEPATH SAFEPATH. Emergency communications system

SAFEPATH SAFEPATH. Emergency communications system SAFEPATH SAFEPATH Emergency communications system ALERiTY Integrated mass notification solutions by Eaton; designed to protect, alert and inform your most critical resources your people ALERiTY /a ler

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

s Notification Appliances

s Notification Appliances s Notification Appliances Data Sheet Fire Safety Products AS & AH Audible Horn Strobe / Audible Horn Appliances Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-R AH-W Product Overview Fast installation

More information

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installing detectors, please thoroughly read the NEMA Guide for Proper Use

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card XP6-C Six Circuit Supervised Control Module and SYNC-1 Accessory Card General NOTIFIER s XP6-C six-circuit supervised control module provides intelligent alarm systems with supervised monitoring of wiring

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity

More information

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Table 1: Models Description Low frequency (520 Hz) horn, white housing, no FIRE marking, standard output clear strobe light Low frequency (520

More information

Detection and Control Components

Detection and Control Components Detection and Control Components FSL-751 Very Intelligent Early Warning (VIEW ) LASER Smoke Detector with FlashScan (IQ-318/IQ-636X-2) Description The FSL-751 VIEW Laser Detector provides a revolutionary

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Approved* TrueAlert Addressable Notification Appliances Audible Notification Appliances; Multi-Tone Horns with 520 Hz Output Features Individually addressed and controlled TrueAlert ES multi-tone

More information

Analog fire panels FPA-1000 Family

Analog fire panels FPA-1000 Family Analog fire panels FPA-1000 Family en NAC Compatibility List Analog fire panels NAC compatibility en 3 1 NAC compatibility 1.1 General notes Bosch Security Systems found the following notification appliance

More information

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM Waterflow Alarm Submittal Booklet For MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM 380 South 5th St Monroe, OR 2G CONSTRUCTION PO Box 11735 Eugene, OR Convergint Technologies LLC 16575 SW 72nd Avenue

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

INSTALLATION AND MAINTENANCE

INSTALLATION AND MAINTENANCE INSTALLATION AND MAINTENANCE DH100ACDCIA & DH100ACDCPA Air Duct Smoke Detector Before Installing ULC standard CAN/ULC-S524-M91 Standard For The Installation Of Fire Alarm Systems should be referenced for

More information

D7024 Fire Alarm Control Panel

D7024 Fire Alarm Control Panel D7024 Fire Alarm Control Panel The D7024 offers accurate, consistent performance with a feature set that elevates this panel to the top of its class. Fire systems you can rely on. D7024 24V Addressable

More information

Hazardous Location Supervised Warning Light

Hazardous Location Supervised Warning Light FEDERAL SIGNAL CORPORATION Hazardous Location Supervised Warning Light Model 154XST RUGGED DESIGN FOR USE IN HAZARDOUS LOCATIONS Available in 24VDC Four wires and supervisory diode Six dome colors 10,000-hour

More information

SELECT-A-HORN/STROBE SERIES

SELECT-A-HORN/STROBE SERIES SELECT-A-HORN/STROBE SERIES Features Description Mircom s Select-A-Strobe/Horn Series is designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency

More information

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

June 10, 2002 DF C S2424

June 10, 2002 DF C S2424 GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other

More information

DH500ACDC Intelligent Air Duct Smoke Detector Housing

DH500ACDC Intelligent Air Duct Smoke Detector Housing INSTALLATION AND MAINTENANCE INSTRUCTIONS DH500ACDC Intelligent Air Duct Smoke Detector Housing 3825 Ohio Avenue St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 Specifications Length: 14.5

More information