SWITCHING POWER GENERATOR FOR 0.9 & 1.2 KW MAGNETRON TECHNICAL NOTE

Size: px
Start display at page:

Download "SWITCHING POWER GENERATOR FOR 0.9 & 1.2 KW MAGNETRON TECHNICAL NOTE"

Transcription

1 CM340 - CM440 E and F series SWITCHING POWER GENERATOR FOR 0.9 & 1.2 KW MAGNETRON TECHNICAL NOTE (issue November 2006)

2 CE Declaration of Conformity Dichiarazione di Conformità CE Manufacturer s Name: Nome del Costruttore: Manufacturer s Address: Indirizzo del Costruttore: ALTER s.r.l Via Curie, Reggio Emilia - Italy Declare that the product: Dichiara che il Prodotto: product name: nome prodotto: model: modello: CMx40F (power supply), TMx10 and TMx12 (microwave generator head) CMx40F.xxx0, CMx40F.xxx1, CMx40F.xxx04, TMx10.xxx0, TMx12.xxx0 Complies with the following norms: EN : A2: 1996 (EN 61010: A2: 1995) Soddisfa le seguenti norme: EN55011: 1991 EN (burst); EN (power fail); EN (surge) The products listed above comply with the requirements of the Low Voltage Directive 73/23/EEC. I Prodotti sopraindicati sono conformi con la Direttiva di Bassa Tensione 73/23/EEC Reggio Emilia, November Marco Garuti Presidente C.d.A. Rev. Revision note Date File 0 First emission September 2000 CM340_r0 1 Added technical specs for CM 440 June 2002 CM340_r1eng 2 Output ripple, filam transf.,reference signal March 2003 CM340_r2eng 3 Upgraded data in-out current August 2004 CM340_r3eng 4 Internal fuses specs & RoHS declaration July 2006 CM340_r4eng 5 Fuses specs series F & power limited vers. November 2006 CM340_r5eng File:CM340_r5eng - November Technical note: vers. 0 e 1 page 1 of 12

3 Alter policy about Reduction on Hazardous Substances (RoHS) and Waste Electrical and Electronic Equipment (WEEE) Law Reference Directive 2002/96/EC of European Parliament (WEEE) Directive 2002/95/EC of European Parliament (RoHS) Decreto Legislativo D.L. n /07/2005 (WEEE and RoHS) Starting from September 2005 Alter has set the rule to accept only RoHS compliant components from its Suppliers. At the present date of 15 May 2006, 90% of components in our stock is RoHS compliant. The components still not compliant were hold in stock and still used for two reasons: there is not the same or equivalent product RoHS compliant, or the product is a spare part for equipment produced and put on market before 1 st July Alter Risk Assessment on RoHS Of the six substances forbidden from electronic equipment (Lead (Pb), Mercury (Hg), Cadmium (Cd), Hexavalent Cromium (Cr-VI), Polybrominated biphenyls (PBB), Polybrominated diphenyl ethers (PBDE)) only two are used in Alter s current manufacturing process, Pb and Cr-VI, of whose lead is the more important. Mercury: Cadmium: Pbb & Pbde: Cr-VI: Lead: not present, never used was present as part of alloy on relay contact. We are using relay RoHS compliant now. Never used as anti-corrosion coating on metal parts. may be present in some cables and insulating material in the past. We are using only RoHS compliant suppliers and products now. is used as anticorrosion layer on aluminium part. We are evaluating alternative coating. It is still present within the limit of 0,1% in weight as set by Directive. it is largely used as an alloy for welding of electronic parts. We are already using alternative alloys lead-free, but as we still have components that cannot be soldered without lead, we have to use some lead-alloy for welding. At present there are still general concerns about reliability over the time of a soldered electronic joint done without traditional Sn/Pb alloy. We are putting any effort on reducing lead weight within 0,1% of products as set by Directive. Important information to User about disposal, recycling, reuse of this electronic equipment at the end of its useful life (WEEE Directive). According to Annex IA and IB of EC Directive 200/96/EC this equipment is not included on the list of categories/ products covered by the Directive (as a matter of fact it does not perform a function alone, must be included into a larger process equipment and it s for stationary use). Nevertheless we invite the User to respect the following Directive rules: this WEEE is not a municipal waste and should be collected separately according to rules of your country the symbol means that this WEEE cannot be disposal in the same place and in the same way like municipal waste this WEEE may present risk for environment as well as for person in case of disposal in unauthorized place, due to content of hazardous substances for disposal of this WEEE in unauthorized area the User may be charged with a fine or prosecuted by law. page 2 of 12 File: CM340_r5eng - November Technical note: vers. 0 e 1

4 Contents C CE Declaration 1 Cleaning 9 Components layout 9 Component list 9 E Environmental conditions 5 Equipment installation 5 Equipment operation 5 Equipment ratings 4 G General Description 4 General Information 3 H How to order 11 I Internal fuses location 8 L LED meaning 6 O Operating controls 5 P Physical characteristics 5 Pin out of CONN. # 1 and 2 10 R RoHS conformity 2 T Technical assistance 11 W Warnings 3 General Information This equipment satisfies the European Standard EN (=CEI 66-5) (=IEC ) approved by CENELEC on 9/3/1993. With reference to EN standard, note: this appliance must be installed and serviced only by qualified personnel. The appliance must only be used by persons acquainted with the regulations covering the application. Note about EMC regulation: the equipment described in this manual has been classified as industrial, scientific and medical (ISM) radio-frequency equipment and the related standard for the emission is EN55011 (title: Limits and methods of measurement of radio disturbance characteristics of ISM equipment.) With reference to the EN55011 standard, this equipment is included into Group 2 (Microwave generators, Thyristor command equipment, Welding equipment, Induction heating equipment or machine, Microwave industrial oven, etc.), Class A (industrial environment): for this reason this equipment shall not be used in the residential, commercial and light-industrial environment. The CMx40 and TMx10, when properly installed, complies with the limits of radio disturbance characteristic of a Group2, Class A equipment as stated by EN A copy of the tests performed may be sent on request. Note that these tests cannot be used as a conformity certificate of the user s final equipment. WARNINGS The CMx40 is powered by 230V main line and has high voltage output (close 4 kv): read carefully this manual before using. Be sure of that the equipment is correctly connected as described below. Failure to comply with the instructions enclosed in this manual may involve considerable risks for the staff responsible for checking and using the equipment, as well as the risk of general malfunctions of the equipment itself. File:CM340_r5eng - November Technical note: vers. 0 e 1 page 3 of 12

5 General Description The CM340 power supply is able to supply, from remote location, the current necessary for a 900 W magnetron, like the 2M107, 2M167 or equivalents, observing the specifications set by the electron tube manufacturer, while CM440 is suitable for a 1250 watt magnetron, like the 2M137 or equivalent. This constructional choice -separation between the power supply unit and the microwave head- allows great freedom in positioning, even at long distance, the microwave emitter head, thus simplifing installation and maintenance. In this manual the term CMx40 refers to both the models (CM340 and CM440). The CM switch-mode power supplies are suitable to control the magnetron power with better performances compared to conventional thyristor controlled power supplies and lower output ripple. Therefore the CM is not a low ripple. In addition to powering magnetron, CMx40 generator also supplies power to magnetron cooling fan, it monitors magnetron temperature, carries out a number of monitoring processes independently, cuts off the power in case of malfunction and display the alarms by means of LED as explained hereinafter. The output power can be adjusted from the outside on a continuous scale using an external analog signal: various options are available. Equipment ratings CM340 CM440 Input voltage (nominal): 230 Vac Absolute max input voltage: 265 Vac Absolute min input voltage: 190 Vac Line frequency: 50/60 Hz RMS current (@230 Vac): 10 A 12 A Average current (@230 Vac): 6 A 7 A Power factor: 0.66 Output power: 1350 W 1850 W Output 40 C 350 ma 420 ma Suggested magnetron type: 2M167 2M137 2M107 Filament preheating delay: 14 sec Suggested filament trafo type: FIL35F FIL65F Remote control (ON/OFF enabling): 8-24Vdc, common to ground Analog reference signal: 0 10V Measuring output current signal: 1V=100mA (Z=250Ω) Transient overvoltage: overvoltage category II according IEC664 Internal alarm contact: Max 130V 1A Operation modes of the alarm contact: a) power supply OFF: open contact b) power supply ON, ok status: closed contact c) power supply ON, alarm condition(s): open contact Output stability: max 3% with +/-10% fluctuation of main line page 4 of 12 File: CM340_r5eng - November Technical note: vers. 0 e 1

6 Physical characteristics Front panel size (w x h): Equipment lenght: Minimum footprint on cabinet: Equipment weight: Use: Altitude: 180 x178 mm 280 mm 330 x 250 mm 4 kg (9 lbs) Environmental condition Temperature: Relative Humidity: Pollution degree: Indoor use only tested up to 2,000 m (6,560 feet) 5 C to 40 C (41 F to 104 F) 80% RH for temperature up 31 C (88 F), decreasing linearly to 50% RH at 40 (104 F) 2, according IEC664 Equipment installation The CMx40 cannot operate on a bench: it must be installed into a proper closed cabinet, providing all the rules necessary to comply with the safety norms for the electrical equipment. The equipment must be safely fixed inside a cabinet by means of screws on the base (which has 4 holes). We suggest a vertical installation on the internal supporting panel of a cabinet. It shall be forbidden to make maintenance on the CMx40 while it s powered: provide safety rules like for any other power equipment installed inside an electrical cabinet. I.E.: if the door of the cabinet may be opened without any tool, then provide an interlock to shut-off main supply from the CMx40. If you install several CMx40 inside the same cabinet then design the air cooling system considering the following: - one CMx40 requires approx 70 m³/h, - the air flow enters from the fan and exits by the side grids. Equipment operation Power ON Refer to wiring diagram at page 10, Connector #1: connect main line to pin 1 and 2 (phase/neutral or phase/ phase), ground to pin 3. The pins 4 and 5 are outputs (internally are connected to pin 1 and 2) and provide main line - as it is - to power the remote head (filament transformer). Filament preheating Once powered throu pin 1 and 2 (Conn #1) the CMx40 starts an internal timer that lasts 14 seconds to allow the preheating of the magnetron s filament. During timer-on the Enabling command (to enable microwave power) is non-operating and doesn t have any effect. Warning: If the Enabling command is set ON during filament preheating, at the elapse of timer the CMx40 powers the head to produce microwave. Operating controls The CMx40 operation is controlled by an external command at +24 Vdc (nominal): the voltage range may vary from 8 to 24 Vdc, common to ground, Z=10 kohm. The command signal must be wired to pin 9 of the Connector #2: if the user doesn t have a suitable voltage generator for this signal, then the equipment s internal voltage generator is available at pin 8 of Connector #2. In this case, to enable the equipment operation, the user must provide an external contact closing the circuit between pin 8 and pin 9. Refer to wiring diagram at page 10 Warning: do not hold the Enabling command ON when you apply main line to unit (power-on) or you can get an alarm. The Enabling command must be OFF when the CMx40 is powered. When the command is ON and the followings condition are satisfied: - the CMx40 has been properly connected to a remote microwave head - there are not alarms conditions - the filament preheating has been completed, then File:CM340_r5eng - November Technical note: vers. 0 e 1 page 5 of 12

7 the CMx40 reach the preset value of anodic current and power-up the remote microwave head. On the front panel there are the following LED indicators: - 1 ON status green LED - 4 alarms status red LEDs - 1 enabling status blue LED - 1 interlock status green LED POWER ON (green): LED meaning: ON when the main line is present voltage side dropped under 2 kv for period longer than 0.4 msec. This is a permanent alarm: to reset the alarm condition switch-off or disable the equipment. RACK OVERTEMP(red): OFF when no alarm is present. ON for internal over temperature. This is a permanent alarm: to reset the alarm condition switch-off or disable the equipment. OVERVOLT (red): LEAKAGE (red): OFF: no alarm ON: anodic overvoltage > 5kV for period longer than 0.4 msec. This is a permanent alarm: to reset the alarm condition switch-off or disable the equipment. OFF: no alarm ON: current leakage detected, as the high TUBE OVERTEM. (red): OFF for normal operation. ON for magnetron overtemp. (or when the related connection is not grounded). It is designed to work with a thermoswitch normally closed to ground. This is a permanent alarm: to reset the alarm condition switch-off or disable the equipment. page 6 of 12 File: CM340_r5eng - November Technical note: vers. 0 e 1

8 ENABLE (blue): INTERLOCK (green): OFF: output power is OFF. ON: enabling signal is present: the equipment produces output power at the level set by reference signal. OFF: the interlock circuit is open, the output power is OFF ON: the interlock circuit is closed and the unit may power the microwave head. Alarm management The top and bottom sides contain the following components (the number in brackets [ ] refers to drawing Terminal board view-fan view ): - two MSTB types, Phoenix connectors, one with 5 pins (CONN. #1) [1] for the generator electrical power supply, the other with 10 pins (CONN. #2) [2] for signal - a small cover [3] to access the High Voltage output on p.c.b. (by means of a faston) on the CMx40 standard version (ver. 0) or - a H.V. connector -Y serie made by LEMO, bulkhead type- on CMx40 version 1 - a M5 screw [4] for direct ground connection of the magnetron s ground - a label with the equipment s data [5] - the cooling air intake grid and fan- [6] Important note: any alarm condition causes block of the equipment, which means no output power and opening of the alarm contact. Reset procedure: remove the alarm cause, hold the enabling signal OFF for at least 3 seconds MODEL P/N alte r REGGIO E. - ITALY S/N DATE POWER KVA CURRENT A 3 INPUT V FREQ. Hz 4 ATTENZIONE! COLLEGARE AL MORSETTO DI TERRA DELLA TESTA. IL MANCATO COLLEGAMENTO PUO CAUSARE PERICOLO DI MORTE! ATTENZIONE! ALTA TENSIONE WARNING! CONNECT TO THE GROUND POINT OF THE HEAD. ABSENCE OF PROPER GROUNDING MAY CAUSE DEATH! WARNING! HIGH VOLTAGE 181 M2 012 File:CM340_r5eng - November Technical note: vers. 0 e 1 page 7 of 12

9 Power board M270.1 for CMx40 E series (till P.S.U. s/n: 328) On the Power board M270.1 are located three fuses having the following characteristics: Fuse F1 and F2 (main fuses)* - Size, type: 6.3x32 mm, ceramic - Speed action: quick (F) - Rated current: 20 A Fuse F3 (low voltage transformer protection fuse)* - Size, type: 5x20 mm, ceramic - Speed action: slow-blow (T) - Rated current: 100 ma Power board M270.2 for CMx40 F series (starting from P.S.U. s/n: 329) On the Power board M270.2 are located five fuses having the following characteristics: Fuses F1 and F2 (main fuses)* - Size, type: 6.3x32 mm, ceramic - Speed action: quick (F) - Rated current: 20 A Fuses LVR1, LVR2 and LVR3** (resettable, not replaceable) - fuse LVR1: protects from short-cir cuits on low voltage transformer and related control circuits - fuses LVR2 and LVR3: protect from damages on the output lines to the head Internal fuses location FUSE F1 FUSE F2 FUSE LVR1 FUSE LVR2 FUSE LVR3 * Note: to replace the fuses proceed as follows: - locate and remove the failure cause - remove main from the equipment and wait 5 minutes to allow the discharge of the internal capacitors - remove the aluminium cover - replace the blown fuse with a new one having the same electrical characteristics ** Note: in case of trip of resettable fuses: - locate and remove the failure cause - remove main from the equipment - wait for the necessary cooling of the fuse (it may take also many minutes) page 8 of 12 File: CM340_r5eng - November Technical note: vers. 0 e 1

10 Equipment maintenance Cleaning Once a week inspect the inlet mesh of the cooling air as well as the outlet grid. In case the equipment needs to be cleaned then proceed as follow: - switch off the external circuit breaker or whatever device provided to remove the main from the equipment; - remove the main connector #1 (5 pins) - remove the cover - remove dust with dry air - reinstall cover: tighten all the screws - plug the connector #1 Failure to comply with these instructions may involve considerable risks for the staff using the equipment, as well as the risk of malfunctions of the equipment itself. COMPONENT LIST Pos Q.ty Description P/N Note 1 1 Grid VELZ Fan, dim. 80x80x25 mm VE8412NGH 3 1 Control board Display board For E and F series pins, plug MOPHOEN/ CONN.# pins, plug MOPHOEN/ CONN.#2 7 1 H.V. board File:CM340_r5eng - November Technical note: vers. 0 e 1 page 9 of 12

11 Pin out of CONN. # 1, 2 page 10 of 12 File: CM340_r5eng - November Technical note: vers. 0 e 1

12 Power supplies: where: x (output current): ccc: j (unit version): How to order CMx40F.cccjpb 3 = 350 ma (900W magnetron) 4 = 420 ma (1250W magnetron) the code used for a castomized unit 0 or nul= standard version, no HV connector 1=version 1: has the HV Lemo connector (bulkhead type) p (power limitation): 4 = 130 ma (~ 400 W) b (bus type code): 0 or nul= no bus C = CANBUS interface Cable set: (Standard lenght 3 mt; other lengths available on request) = full set for CMx40 version 0, include the plugs on the p.s.u. side (no HV plug) = full set for CMx40 version 1, includes the plugs on the p.s.u. side and also the HV plug = full set for CMx40 version 0, includes the plugs on the p.s.u. side (no HV plug) and plugs for TMx = full set for CMx40 version 1, includes the plugs, the HV plug on the p.s.u. side and plugs for TMx I.e.: CM340F = standard version without bus interface; CM340F.1= version 1 with HV connector, no bus CM340FC.1=version 1 with HV connector and CANBUS interface Note: the power supply s package does not include the plugs: these must be ordered separately Plugs set: p/n 44SET340= for CMx40 vers. 0 p/n 44SET341= for CMx40 vers. 1 Filament transformers: FIL65F= filament transformer for 2M137 magnetron and similar FIL35F= filament transformer for 2M107 magnetron and similar Alter reserves the right to improve or modify this products, at any time, without any obligation to notify any person or entity of such changes. No part of this publication may be reproduced without the express written consent of Alter. All rights reserved. Technical assistance For technical assistance as well as spare parts contact your closest distributor or: Alter s.r.l Reggio Emilia - ITALY Tel ; fax Web: Microwave heads: TMx10.yyy0 = complete microwave head, includes the magnetron (air or water cooled version available) See manual TM0-TMA File:CM340_r5eng - November Technical note: vers. 0 e 1 page 11 of 12

13 page 12 of 12 File: CM340_r5eng - November Technical note: vers. 0 e 1

MPS 96 TECHNICAL NOTE. MULTICHASSIS SWITCHING PSU FOR 60 kw MAGNETRON C.W. INCLUDES: SM 1816 POWER MODULE AC 570 CONTROL MODULE. (issue March 2008)

MPS 96 TECHNICAL NOTE. MULTICHASSIS SWITCHING PSU FOR 60 kw MAGNETRON C.W. INCLUDES: SM 1816 POWER MODULE AC 570 CONTROL MODULE. (issue March 2008) MPS 96 MULTICHASSIS SWITCHING PSU FOR 60 kw MAGNETRON C.W. INCLUDES: SM 1816 POWER MODULE AC 570 CONTROL MODULE TECHNICAL NOTE (issue March 2008) CE Declaration of Conformity Dichiarazione di Conformità

More information

MPS 24 TECHNICAL NOTE. MULTICHASSIS SWITCHING PSU FOR 15 kw MAGNETRON C.W. INCLUDES: SM18XX POWER MODULE AC 440 CONTROL MODULE.

MPS 24 TECHNICAL NOTE. MULTICHASSIS SWITCHING PSU FOR 15 kw MAGNETRON C.W. INCLUDES: SM18XX POWER MODULE AC 440 CONTROL MODULE. MPS 24 MULTICHASSIS SWITCHING PSU FOR 15 kw MAGNETRON C.W. INCLUDES: SM18XX POWER MODULE AC 440 CONTROL MODULE TECHNICAL NOTE (Issue May 2007) CE Declaration of Conformity Dichiarazione di Conformità CE

More information

HUMIDITY AND TEMPERATURE CONTROLLER

HUMIDITY AND TEMPERATURE CONTROLLER HUMIDITY AND TEMPERATURE CONTROLLER HT INSTALLATION, MAINTENANCE AND USER MANUAL Elsteam S.r.l.. Ver. 14.01.UK ToC 1. PACKAGE CONTENT... 3 2. SECURITY MEASURES... 3 1.1 GENERAL MEASURES... 3 1.2 THERMO-HYGROMETRIC

More information

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description. USER GUIDE TB-9022 Iron Man Plus Workstation Monitor Installation, Operation and Maintenance Features and Components Made in the United States of America A B C D Figure 1. Iron Man Plus Workstation Monitor

More information

Installation Manual Premier Elite IXP-W

Installation Manual Premier Elite IXP-W Installation Manual Premier Elite IXP-W INS538-2 1. Contents 1. Contents... 2 2. Premier IXP-W Interface... 3 Premier Elite 8XP-W & 32XP-W Firmware... 3 3. Quick Start Guide... 4 4. System Overview...

More information

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270. Belonging Portable Gas Detector RP110 The RP110 portable gas detector is an electronic instrument manufactured by BEINAT S.r.l. to help technicians during testing or to search for and locate leaks in gas

More information

Operating Instructions

Operating Instructions Operating Instructions ProVicom MT-65, MT-125 R. STAHL HMI Systems GMBH Im Gewerbegebiet Pesch 14 50767 Köln Version 1.7 Issue: 21.07.2008 R. STAHL HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc

More information

Premier External TD. Installation Manual INS352-3

Premier External TD. Installation Manual INS352-3 Premier External TD Installation Manual INS352-3 1. Accessing the Unit 1 2 Remove the top cap and loosen screw (screw retained in wall plate). Push up head unit and remove. 3 Use a flat head screwdriver

More information

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012 Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012 Two Parts: 1. Products first placed on the market between 1 July 2006

More information

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1 Instruction Manual M6627 / Version 7.4 Slide Drying Bench MH6616 MH6616X1 Please take your time to read this Instruction Manual in order to understand the safe and correct use of your new Electrothermal

More information

KM300 Carbon Monoxide Detection System Installation Manual

KM300 Carbon Monoxide Detection System Installation Manual GE Security KM300 Carbon Monoxide Detection System Installation Manual P/N 1068922 REV 2.0 16SEP09 Copyright Copyright 2009 GE Security, Inc. All rights reserved. This document may not be copied in whole

More information

ULTRASONIC HUMIDIFIER UHF

ULTRASONIC HUMIDIFIER UHF GUIDE D UTILISATION, INSTALLATION MAINTENANCE ET USAGE ULTRASONIC HUMIDIFIER UHF USER, INSTALLATION AND MAINTENANCE GUIDE Elsteam S.r.l.. Rel. UHF.18.01.EN Ultrasonic Humidifier UHF Rel: UHF.18.01.EN 2

More information

Installation Manual. Premier IXP-W INS538

Installation Manual. Premier IXP-W INS538 Installation Manual Premier IXP-W INS538 1. Contents 1. Contents... 2 2. Premier IXP-W Interface... 3 Premier 8XP-W & 32XP-W Firmware... 3 3. Quick Start Guide... 4 4. System Overview... 5 Mounting the

More information

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR instruction manual Ref No: NISM/EVC-P/03 Date: Jan 2010 Issue: 3 Quality System Certificate No. 041 Assessed to BS EN ISO 9001:2000 NITTAN (UK) LTD. Hipley

More information

Owner & Operator s Manual. Table of Contents

Owner & Operator s Manual. Table of Contents Owner & Operator s Manual Model No. Voltage Frequency 908041/9495160 100-120V 50 60 Hz 9495161 230V 50 60 Hz Table of Contents DESCRIPTION PAGE Safety 2 Technical Data 2 Unpacking Instructions 3 General

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up. PD100MF0MPx Surface Mount Type, Opaque Resin Photodiode Features 1. Compact and thin SMD package 2. Top view and side view mountable 3. Plastic mold with visible light cut-off black resin lens 4. Peak

More information

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24 Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24 Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms, 50/60

More information

PROCESSING UNIT II V Hz V Hz. Table of Contents

PROCESSING UNIT II V Hz V Hz. Table of Contents PROCESSING UNIT II Owner & Operator s Manual Model No. Voltage Frequency 9494800 120V 50 60 Hz 9494801 230V 50 60 Hz Table of Contents DESCRIPTION PAGE Safety 2 Technical Data 3 Installation Instructions

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E06/TR04.1 Original: English Distribution: General TITLE: Wall-mounted pen recording thermometer Specification reference: E06/TR04.1 Product verification protocol:

More information

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms, 50/60

More information

USER S MANUAL. Rectifier 1 10 A/10 48 V for Kliar Line Art

USER S MANUAL. Rectifier 1 10 A/10 48 V for Kliar Line Art USER S MANUAL Rectifier 1 10 A/10 48 V for Kliar Line Art. 3004052 Dichiarazione CE di Conformità CE Conformity Declaration TIPO DELLA MACCHINA: RADDRIZZATORE 1 PRODUCT TYPE: RECTIFIER 1 Modello/ Model

More information

HULME MARTIN HEAT SEALERS

HULME MARTIN HEAT SEALERS HM1000P Operating Instructions HULME MARTIN HEAT SEALERS HULME MARTIN HEAT SEALERS www.hulmemartin.co.uk SAFETY INSTRUCTIONS HEAT SEALING EQUIPMENT A. Protection against hazards arising from the electrical

More information

Wideband Optical Couplers

Wideband Optical Couplers Flashlink User Manual WOC-2-50-50 WOC-2-90-10 WOC-2-95-05 WOC-4-25 Wideband Optical Couplers network-electronics.com Rev. 3 Network Electronics ASA Thorøya P.O. Box 1020 N-3204 Sandefjord, Norway Phone:

More information

Fortimo LED Line Gen2 Module

Fortimo LED Line Gen2 Module Fortimo LED Line Gen2 Module Fortimo LED Line 1ft 650lm 3R LV2 Fortimo LED Line systems are designed to replace fluorescent lighting in new luminaires. Fortimo LED Line Gen 2 systems are designed to replace

More information

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 3490 Series 4 20 ma + HART Compatible Controller 00825-0200-4841, Rev AB Rosemount 3490 Series 4 20 ma + HART Compatible Controller Failure to follow safe installation guidelines could result in death or serious injury The Rosemount 3490 Series Control

More information

Door Release Power Supply

Door Release Power Supply www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation

More information

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - USER GUIDE DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - II CONTENTS 1. SYMBOLS AND WARNINGS... 5 2. GENERAL INFORMATION... 6 3. WARNINGS... 7 4. GENERAL DESCRIPTION... 8 5. INSTALLATION...

More information

Fortimo LED Line High Flux Module

Fortimo LED Line High Flux Module Fortimo LED Line High Flux Module Fortimo LED line 2ft 4000lm 1R LV1 The Fortimo LED Line high flux systems consist of linear white light LED modules with high flux, high energy efficiency, and high quality

More information

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47) DIESEL ENGINE CONTROL UNIT DCU 205 - USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) 64 84 52 00 Fax: (+47) 64 84 52 12 office@auto-maskin.no - 1 - TABLE OF CONTENTS 1. INTRODUCTION TO THE DCU 205...4

More information

RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS

RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS TITLE: NUMBER: REVISION: RoHS Certificate of Compliance for IntelliTouch Super Flat Profile Screens ES500345 B Sheet 1 of 6 Change

More information

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts Figure 1Document: SPEC-112 Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts construction requirements of UL approved Class H (180 C) insulation system. Transformers

More information

CE GUIDELINE IEC. CENELEC (Comité Européen de Normalisation Electrotechnique European Electrotechnical Standardisation Comitee)

CE GUIDELINE IEC. CENELEC (Comité Européen de Normalisation Electrotechnique European Electrotechnical Standardisation Comitee) INDUSTRIAL GROUP PRODUCT BROCHURE 2014 CE GUIDELINE CE Mark is the abbreviation of Conformity European and in literature mainly means conformity to European Norms. Any product or any product group carrying

More information

MicroCoat Flow Guard Operating Manual

MicroCoat Flow Guard Operating Manual A NORDSON COMPANY MicroCoat Flow Guard Operating Manual MC480M Series Electronic pdf files of EFD manuals are also available at www.efd-inc.com/manuals.html Contents Introduction...3 Specifications...4

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E006/TH06.2 Original: English Distribution: General TITLE: Integrated electronic thermometer, with or without alarm function, for vaccine refrigerators and freezers

More information

Datasheet: K-22 LO Sensor

Datasheet: K-22 LO Sensor Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter

More information

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens. User Guide Luxxor 35 LED Light Source 207 Tremont Street, Rochester, New York 14608 800.536.0790 Fax: 585.235.6645 REV. 0116 gradientlens.com warnings & cautions Warnings & Cautions PORTABLE CAMERA Luxxor

More information

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH

More information

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC) GPY00AU0F Compact Optical Dust Sensor Description GPY00AU0F is a dust sensor by optical sensing system. An infrared emitting diode (IRED) and an phototransistor are diagonally arranged into this device.

More information

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content 8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity

More information

GigaCore RPSU. Redundant power supply for GigaCore 14R and 16Xt. Quick Start Guide. V2.0.0 Rev1. English

GigaCore RPSU. Redundant power supply for GigaCore 14R and 16Xt. Quick Start Guide. V2.0.0 Rev1. English GigaCore RPSU Redundant power supply for GigaCore 14R and 16Xt Quick Start Guide V2.0.0 Rev1 English Table of Content Safety Instructions 3 Compliance information 4 Warranty information 5 Registration

More information

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms,

More information

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Undercounter Refrigerator Operation Manual i.series and Horizon Series Undercounter Refrigerator Operation Manual i.series and Horizon Series Blood Bank Models i.series: ib105 (Version B) Horizon Series: HB105 (Version B) Laboratory/Pharmacy Models i.series: ilr105 (Version

More information

OVC OVC2000. New Family of Electronic Oven Controls

OVC OVC2000. New Family of Electronic Oven Controls OVC1000 - OVC2000 New Family of Electronic Oven Controls OVC1000 - OVC2000 OVC = new family of power boards for electronic OVen Controls, developed in Rothenburg 2 levels of complexity (denomination aligned

More information

ETH1000-MKII. User manual

ETH1000-MKII. User manual ETH1000-MKII Gigabit Ethernet Media Converter User manual Rev. 1 1 Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99 Nevion

More information

Use & Care Manual Contemporary Electric Fires

Use & Care Manual Contemporary Electric Fires Use & Care Manual Contemporary Electric Fires These instructions are for your safety. Please read through them thoroughly before use and retain for future reference. Failure to follow them could cause

More information

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw Industrial Solid State Contactor TE10S Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw Partial load failure (PLF) detection option User Manual Copyright Eurotherm Automation

More information

ULTRASONIC HUMIDIFIER

ULTRASONIC HUMIDIFIER ULTRASONIC HUMIDIFIER USER, INSTALLATION AND MAINTENANCE GUIDE Rev 12.02-EN 2 1 Package content... 3 2 Security measures... 3 3 Conformity... 4 4 Working principle... 5 5 Characteristics... 5 6 Installation...

More information

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document 1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need for

More information

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at PHASE ROTATION METER 6608 L1/A L2/B 690V 600V CAT III 300V CAT IV L1L2L3 L3/C L R PHASE ROTATION MODEL 6608 User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431

More information

NRS1/NRS1-R RAIN SENSOR LOW TENSION HEATED RAIN SENSOR (R-RADIO VERSION) MANUAL FOR INSTALLATION AND USE. Symbols used in the manual.

NRS1/NRS1-R RAIN SENSOR LOW TENSION HEATED RAIN SENSOR (R-RADIO VERSION) MANUAL FOR INSTALLATION AND USE. Symbols used in the manual. The device described in this manual has been manufactured in accordance with safety standards and conforms to the stipulations of current standards in force. When correctly assembled, installed and used

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1 Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance

More information

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

INSTALLATION GUIDE. AXIS A1001 Network Door Controller INSTALLATION GUIDE AXIS A1001 Network Door Controller Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis

More information

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics... 14 Ex SOLENOID / ALARM DRIVER PRepower 5203B Table of contents Warnings... 16 Safety instructions... 17 Declaration of Conformity... 19 How to dismantle SYSTEM 5000... 20 Application... 21 Technical characteristics...

More information

USE AND MAINTENANCE MANUAL

USE AND MAINTENANCE MANUAL USE AND MAINTENANCE MANUAL FSC25 PAY ATTENTION: when switch over from AUTomatic to CONTinuous functioning using front switch, wait at least one second in position OFF (0); otherwise it s possible to cause

More information

43PFL6572/V7 39PFL6572/V7 32PFL6572/V7

43PFL6572/V7 39PFL6572/V7 32PFL6572/V7 43PFL6572/V7 39PFL6572/V7 32PFL6572/V7 2 Page Blank Product disposal Guidelines: return this product to a nearby authorized collection center, registered dismantler, recycler, service center when disposing

More information

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller IP2030/QS, Rev AB Mobrey MCU900 Series 4 20 ma + HART Compatible Controller Quick Start Guide for Installation Failure to follow safe installation guidelines could result in death or serious injury The

More information

IR Speed Dome. Quick Guide UD.6L0201B1357A01

IR Speed Dome. Quick Guide UD.6L0201B1357A01 IR Speed Dome Quick Guide UD.6L0201B1357A01 IR Speed Dome Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual

More information

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion. 18 channel CWDM mux/demux User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1:

More information

USER S MANUAL. 4 5-liters Tanks e- coating and galvanic Plant with Ultrasonic Art

USER S MANUAL. 4 5-liters Tanks e- coating and galvanic Plant with Ultrasonic Art USER S MANUAL 4 5-liters Tanks e- coating and galvanic Plant with Ultrasonic Art. 3007091 Dichiarazione CE di Conformità CE Conformity Declaration TIPO DELLA MACCHINA: PRODUCT TYPE: Modello/ Model IMPIANTO

More information

Smart BUS (S-BUS) Home Automation System Simplified Specification

Smart BUS (S-BUS) Home Automation System Simplified Specification Smart BUS (S-BUS) Home Automation System Simplified Specification I - Introduction: This Document is constructed to assist Consultant and Designer in specifying latest Home Automation Technology Standards

More information

Features. Figure 1. Recommended Application

Features. Figure 1. Recommended Application Features High energy density User programmable hold-up trip voltage Trip status indicator Designed for use with Calex DC/DC Converters Small package design (1.45 x 2.28 x 0.50 ) Excellent MTBF Aluminum

More information

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights. CLARA AC CLARA AC Crystal CLARA AC 50 LED-modules for downlight A qualified solution to replace and exceed Halogen solutions in Downlights. No Driver is required! Page 2 of 24 Designed for downlight and

More information

Reflector T2 and GU10 6,000 hours

Reflector T2 and GU10 6,000 hours Reflector T2 and GU1 6, hours 11watt SES E14 Small Screw Cap Equivalent to 6watt R63 information CFL Reflector and GU1 6, hours lamps offer traditional incandescent and halogen shapes and sizes, long life

More information

1X-F Series Installation Manual

1X-F Series Installation Manual 1X-F Series Installation Manual P/N 501-415003-1-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire

More information

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English GigaCore 12 Gigabit Ethernet Switch for the entertainment industry Quick Start Guide V2.1.0 Rev5 English Table of Content Safety Instructions 3 Compliance information 4 Warranty information 5 Registration

More information

INSTRUCTION MANUAL (English version) Water still

INSTRUCTION MANUAL (English version) Water still INSTRUCTION MANUAL (English version) Water still Model : Brand : W4000 Merit Merit Water Still W4000 & W4000/EURO Cooling water inlet Condenser Constant level control Boiler Thermostat reset buttons To

More information

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features Application Note SMART Dust Sensor SM-PWM-01C SM-PWM-01C dust sensor detects dust particle concentration in air by using an optical sensing method. An infrared light emitting diode (IR LED) and a photo-sensor

More information

C-Bus Four Channel Analogue Output Unit Installation Instructions

C-Bus Four Channel Analogue Output Unit Installation Instructions C-Bus Four Channel Analogue Output Unit Installation Instructions 5504AMP Series REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3 4.0 Wiring

More information

USER GUIDE v1.4. Introduction. This document discusses the use and architecture of the OptiGrid Structured Illumination System.

USER GUIDE v1.4. Introduction. This document discusses the use and architecture of the OptiGrid Structured Illumination System. USER GUIDE v1.4 Introduction This document discusses the use and architecture of the OptiGrid Structured Illumination System. The OptiGrid Structured Illumination System is an optical sectioning device

More information

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L 9-channel CWDM multiplexer and demultiplexer / multi mode (-M) / -low-loss (-L) User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway

More information

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System) QC 080000 Edition 3.0 2012-05 IECQ PUBLICATION IEC Quality Assessment System for Electronic Components (IECQ System) Hazardous Substance Process Management System Requirements (HSPM) INTERNATIONAL ELECTROTECHNICAL

More information

Use & Care Manual Inset Electric Fires

Use & Care Manual Inset Electric Fires Use & Care Manual Inset Electric Fires These instructions are for your safety. Please read through them thoroughly before use and retain for future reference. Failure to follow them could cause injury

More information

ETH1000-D. User manual

ETH1000-D. User manual ETH1000-D Gigabit Ethernet Media Converter with DWDM laser User manual Rev. 2 Nevion Europe P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www. Nevion Support Nevion Europe

More information

CU-02 with Senaco Plus

CU-02 with Senaco Plus CU-02 with Senaco Plus Instruction Manual PL-509 July 2001 U-02 SENACO 33455090 Rev. 1.1 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect

More information

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1 Lodam Compressor Protection Module Technical manual Version 3.0 SE-G1 Contents 1. Read this first... 4 1.1. Reading instructions... 4 1.2. User manual... 4 1.3. Safety... 4 2. General... 5 3. Definitions...

More information

HULME MARTIN HEAT SEALERS

HULME MARTIN HEAT SEALERS HM Operating Instructions HM 7600 CDL HULME MARTIN HEAT SEALERS HULME MARTIN HEAT SEALERS www.hulmemartin.co.uk SAFETY INSTRUCTIONS HEAT SEALING EQUIPMENT A. Protection against hazards arising from the

More information

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 The new high-power Q305 laser is an expansion of the existing Q-Series that provides a solution for demanding applications requiring faster throughput.

More information

REA 105 Arc Protection Module. Operator s Manual

REA 105 Arc Protection Module. Operator s Manual REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5

More information

USER AND MAINTENANCE MANUAL

USER AND MAINTENANCE MANUAL FDNF96 DEHUMIDIFIER USER AND MAINTENANCE MANUAL INFORMATION FOR USERS For the purpose and effect of Directives 2002/95/CE, 2002/96/CE and 2003/108/CE, relative to the reduction of the use of hazardous

More information

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature EVCO S.p.A. EV3B24 Data sheet ver. 1.0 Code 1043B24E104 Page 1 of 6 PT 12/15 EV3B24 Basic controller for low temperature bottle coolers, cabinets, refrigerated cabinets, tables and pizza counters, with

More information

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS HP727S Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS 1. General Description 2. Specifications 3. Installation Instructions 4. Electrical Wiring 5. Instrument Wiring

More information

Record of Amendments. Version Date Amendment Section/page affected

Record of Amendments. Version Date Amendment Section/page affected Industry support for effective compliance BTHA Guidance on The Restriction Of The Use Of Certain Hazardous Substances In Electrical and Electronic Equipment (recast) (RoHS) Directive 2011/65/EU Comparison

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA) R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings

More information

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS SERIES 35-65 24 VAC Microprocessor-Based Hot Surface Ignition Control F-35-65 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings* 120/240

More information

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional

More information

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH Page /3 SPECIFICATION SHEET Ed. Document UTE_ Issued Written Verified Approved MP36350 6-05-05 Strizzi Franco Page /3 INDICE HISTORY... 3 MODIFY RECORDING... 3 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

More information

OGB Poly Care 2 Incubator Service Manual

OGB Poly Care 2 Incubator Service Manual OGB Poly Care 2 sevice manual Rev. 05 OGB Poly Care 2 Incubator Service Manual Ginevri s.r.l. 7459bmt November 2009 1 Rev. 05 OGB Poly Care 2 service manual THIS MANUAL HAS BEEN REALIZED RESPECTING THE

More information

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001 POINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS Instruction Manual March 2001 OINTEK CLS 100 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect

More information

KFP-CF Series Operation Manual

KFP-CF Series Operation Manual KFP-CF Series Operation Manual P/N 501-415103-2-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire

More information

5580 S. Nogales Highway Tucson, AZ Phone: (800) Fax: (520) ANAPOD Instructions For Use

5580 S. Nogales Highway Tucson, AZ Phone: (800) Fax: (520) ANAPOD Instructions For Use 5580 S. Nogales Highway Tucson, AZ 85706 Phone: (800) 975-7987 Fax: (520) 294-6061 www.westmedinc.com TM ANAPOD Instructions For Use PN 75054, Rev 02 ii TABLE OF CONTENTS Servicing: Beyond the replacement

More information

ec Preheater User Manual

ec Preheater User Manual ec Preheater DOC.ID: ec 004 999_R02 01 12 2015 www.eurocircuits.com 1 Table of Contents: Application of this device 4 Specifications 5 Declaration of compliance 6 Safety precautions 7 Parts of the device

More information

Important Safety Notice

Important Safety Notice Date: 27 th April 2015 Page 1 of 12 SPI Lasers UK Limited Safety Information High Power OEM Fibre Lasers Important Safety Notice This notice outlines important safety related information and must be read

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11

More information

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ Operating Instructions RTK Instruments Limited PEX7250 Explosion Proof Annunciator Introduction This manual provides the information necessary to install, connect, test and maintain the PEX7250 Explosion

More information

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00 MW 3950 Pince courant de fuite Leakage current Clampmeter Notice d utilisation User s Manual M3950M00 Safety Information To ensure safe operation and service of the Tester, follow these instructions. Failure

More information

Operating instructions

Operating instructions The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...

More information

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality

More information