The right fit for your high-output applications
|
|
- Lindsey Bradley
- 6 years ago
- Views:
Transcription
1 The right fit for your high-output applications Philips Advance programmed-start ballasts for T5HO lamps are available for a wide variety of applications No matter what the conditions require, operating at a variety of line voltages between 0V to 80V, whether located in high ambient temperature environments (requiring a 90 C rating) or not, if you desire hi-low switching options for improved energy efficiency (-lamp models only), our family of Philips Advance ballasts for T5HO lamps are ideal for a wide variety of applications. All of these ballasts utilize programmed-start circuitry which provides extended lamp life in frequent switching applications like those associated with the use of occupancy sensors or motion detectors. These ballasts additionally feature IntelliVolt multiple voltage technology, auto-restrike capability, and lamp End-Of-Life (EOL) protection circuitry which safely removes power from the lamp upon failure. compatible with energy saving lamps. For specific lead lengths visit our e-catalog at Programmed Start Potentially extends lamp life in frequent switching applications such as occupancy sensors or daylight harvesting. -0 F Capability (-9 C) models only). High-Low Switching on -Lamp Models with just one ballast. Our ballasts for T5HO lamps are the optimal choice for a broad range of retail, commercial and institutional and industrial applications including; warehouses, manufacturing, schools, offices, and speciality and department stores. For additional energy saving opportunities Philips Advance T5HO ballasts are
2 No. of Lamps Volts FT5/HO (W) Lamp Method allast Family F9T5/HO (9W) Catalog Number Power ANSI (Watts) allast Factor Max. TH % Line Current (Amps) ICN-S ICN-S ICN-S Min. Temp. ( F / C) im. Wiring iag. 0/-8 0/-8 7 0/ /-8 7 F5T5/HO (9W) HCN-S5-90C-WL L HCN-S5-90C-WL L 7 -G HCN-S5-90C-LS-G F5T5/HO (5W) -G HCN-S5-90C-LS-G G 75 G 75A 7-80 HCN-S5-90C-WL L HCN-S5-90C-WL L 7 -G G 7-80 HCN-S5-90C-LS-G F80T5/HO (80W) -G HCN-S5-90C-LS-G A G 75 ICN-S /-8 FTW/G - /7W (PL-LW, F7X/RS, FTL) ICN-S+ ICN-S /-8 7A
3 No. of Lamps Volts Lamp Method allast Family FT6W/G - 6/9W (PL-L6W, F9X/RS, FT6L) Catalog Number ICN-S+ Power ANSI (Watts) 6 6 allast Factor Max. TH % 5 0 Line Current (Amps) Min. Temp. ( F / C) 7-80 HCN-S5-90C-WL L / HCN-S5-90C-WL L -G HCN-S5-90C-LS-G G HCN-S5-90C-LS-G FT50W/G/RS - 50W (PL-L50W, F50X/RS) im. Wiring iag. 7A G 75A G HCN-S5-90C-WL L A 7-80 HCN-S5-90C-WL L -G HCN-S5-90C-LS-G G HCN-S5-90C-LS-G FT55W/G - 55W (PL-L55W, F55X, FT55L) E 75A E HCN-S5-90C-WL L HCN-S5-90C-WL L 7A -G HCN-S5-90C-LS-G G HCN-S5-90C-LS-G /-8 7A G 75A G 75
4 No. of Lamps Volts Lamp Method allast Family FT80W/G - 80W (PL-L80W, FT80L) Catalog Number Power ANSI (Watts) allast Factor Max. TH % Line Current (Amps) Min. Temp. ( F / C) ICN-S /-8 FC9T5 (W Circline) FCT5 (0W Circline) ICN-S+ ICN-S+ ICN-S im. Wiring iag. 0/-8 0/-8 7 0/ /-8 7 () FC9T5 & () FCT5 {() W & () 0W Circline} & /-8 7 FCT5/HO (55W Circline) ICN-S5*+ ICN-S5-90C* / HCN-S5-90C-WL L ICN-S5*+ ICN-S5-90C* / HCN-S5-90C-WL L
5 -lamp ORANGE LAMP For one lamp operation, do not use yellow leads S ON OFF LAM Neutral or (any hot) LAM ON LAM ON LACK WHITE GREY/RE S 50V, ma RE LUE ROWN YELLOW LAMP LAMP iag. * iag. 75* iag. 7* iag. 75A* * For all HCN ballasts hot leads are black with orange with black and white Grey/red wire must be connected to the neutrals or any hot Fig. Fig. L Fig. Fig. G
6 allast Specification Section I - Physical Characteristics. allast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.. allast shall be provided with integral leads color-coded per ANSI C8.. Section II - Performance Requirements. allast shall be Programmed Start.. allast shall contain auto restart circuitry in order to restart lamps without resetting power.. allast shall operate from 50/60 Hz input source of 0V through 77V or 7V through 80V with sustained variations of +/- % (voltage and frequency) with no damage to the ballast.. allast shall be high frequency electronic type and operate lamps at a frequency between khz and 5kHz to avoid interference with infrared devices, eliminate visible flicker and avoid Article Surveillance Systems, such as anti-theft devices..5 allast shall have a Power Factor greater than 0.98 for primary lamp..6 allast shall have a minimum ballast factor of.0 for primary lamps..7 allast shall provide for a Lamp Current Crest Factor of.7 or less in accordance with lamp manufacturer recommendations. of less than % when operated at normal line voltage with full load primary lamps..9 allast shall have a Class A sound rating.. allast shall have a minimum starting temperature of -8 C (0 F) or -9 C (-0 F) for primary lamp.. allast shall provide Lamp EOL Protection.. allast shall tolerate sustained open circuit and short circuit output conditions without damage. Section III - Regulatory Requirements. allast shall not contain any Polychlorinated iphenyl (PC).. allast shall be Underwriters Laboratories (UL) listed, Class P and Type Outdoor; and Canadian Standards Association (CSA) certified where applicable.. allast shall comply with ANSI C6. Category A for Transient protection.. allast shall comply with ANSI C8. where applicable..5 allast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 7 CFR part 8, Non-Consumer (Class A) for EMI/RFI (conducted and radiated)..6 allast shall comply with UL Type CC rating. Section IV - Other. allast shall be manufactured in a factory certified to ISO 900 Quality System Standards.. allast shall carry a limited warranty from date of manufacture against defects in material or workmanship. (Go to our web site for up-to-date warranty information: Manufacturer shall have a twenty-year history of producing electronic ballasts for the North American market. 0 Philips Lighting Electronics N.A. All rights reserved. Form No. EL / Philips Lighting Electronics N.A. 75 W. Higgins Road Rosemont IL 6008 Tel: Fax: Customer Support/Technical Service: OEM Support:
Hi-lume 3D Overview. Fluorescent Dimming Ballasts
Fluorescent Dimming s Overview 1 architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements. By providing industry leading performance with a full-range of
More informationHi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming
Fluorescent Dimming s Hi-lume 3D Architectural Dimming Hi-lume 3D Overview 369-280f 1 03.08.12 Hi-lume 3D architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements.
More informationEcoSystem H-Series Ballasts
Fluorescent Dimming s Eco H-Series Architectural Dimming Eco H-Series s 369266o 1 11.29.17 Eco H-Series digitally addressable ballasts provide a low-cost, flexible solution for any space in any application.
More informationDALI Interface Dimmable Electronic Ballasts for Fluorescent Lamps / Compact Lamps. Approvals:
DALI Interface Dimmable Electronic Ballasts for Fluorescent Lamps / Compact Lamps FL 13-57/100-277V/50/60Hz TCS/D/T DIM-D Specifications Universal input voltage(120-277vac) Low harmonic distortion (THD
More informationEcoSystem H-Series 347 V~ Ballast Overview
Fluorescent Dimming s EcoSystemR H-Series 347 V ~ Architectural Dimming EcoSystem H-Series 347 V~ Overview 369-352e 1 06.04.12 EcoSystem H-Series digitally addressable ballasts provide a low-cost, flexible
More informationEcoSystem H-Series Ballasts Overview
Fluorescent Dimming s Eco H-Series s Architectural Dimming Eco H-Series s Overview P/N 369-266 rev B 1 11.07.10 Eco H-Series digitally addressable ballasts provide a low-cost, flexible solution for any
More informationNewark, Delaware Architectural Engineering Senior Thesis Portfolio. Electrical Analysis
Electrical Analysis The AstroPower Headquarters building was constructed a few years ago to act as both a Headquarters and to be a display of what the product they manufacture can accomplish when put to
More informationDual Technology Wall Switch Occupancy Sensor. Manual & Specification
Dual Technology Wall Switch Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 November 19, 2014 1. INTRODUCTION
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL
SECTION 265100 - INTERIOR LIGHTING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Interior lighting fixtures, lamps, and ballasts. 2. Emergency lighting units. 3. Exit signs. 4.
More informationModel LTN-3R Outdoor Rated Uninterruptible Power System Single Phase
Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics
More informationBdl60u Fluorescent Emergency Ballast
A Division Of Philips Electronics North America Corporation One- or two-lamp emergency; Universal input voltage: 120 through 277 V, 50 or 60 Hz; Replaces B60U Bdl60u Fluorescent Emergency Ballast Product
More informationQualified Product Information Form for Residential Ceiling Fans
Qualified Product Information Form for Residential Ceiling Fans ENERGY STAR Product Information Form for Use by ENERGY STAR Residential Ceiling Fan Partners (Companies who have joined ENERGY STAR by signing
More informationDimensions (111mm) 3 (76mm) (111mm) (48mm)
Catalog # : Project : Prepared By : Date : S2 The sleek architectural S is designed with tooless entry features saving time and money on installation. Optimizing Industry LED technology, the S series delivers
More informationBAS SDL8' LED Strip Diffused Lens
Project Name Fixture Type Catalog # BAS SDL8' The sleek architectural SDL is designed with tooless entry features saving time and money on installation. Optimizing industry leading LED technology, the
More information600 Watt Dimmer Install Guide
600 Watt Dimmer Install Guide ER6CD This guide covers all models of the ER6CD lighting controller. The box contents includes the controller with lock nut and installation guide. Overview The ER6CD controller
More informationDimensions (111mm) (111mm) 3 (76mm)
Catalog # : Project : Prepared By : Date : S8 The sleek architectural S is designed with tooless entry features saving time and money on installation. Optimizing industry leading LED technology, the series
More informationB. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.
PART 1 GENERAL 1.01 Lighting design: A. Reference UAF Facilities Services Guidelines for Average Illumination Levels. B. It is recognized that these standards are updated irregularly and lighting technology
More informationNational Grid Small Business Program Rebate Manual
National Grid Small Business Program Rebate Manual Rebate Manual Munro Distributing has prepared this manual to aid you and your clients in taking advantage of available rebate programs offered by National
More informationLUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:
LUCE 1 TL indoor / damp Job/Location: Contractor: Prepared By: Job Type: Date: The LUCE-1TL thinline emergency ballast is designed to provide emergency illumination to existing or new fluorescent luminaires.
More informationSECTION INTERIOR LIGHTING
SECTION 26 51 00 INTERIOR LIGHTING PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS
SECTION 260923 LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Wall box mounted, wall/corner
More informationEnergy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight
Directional Luminaire Test Report For ELEC-TECH INTERNATIONAL CO LTD No. 1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R.China 519085 LED Downlight Model name(s):
More informationUltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW
12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes
More informationLED HIGH BAY LINEAR ECO SERIES
PROJECT NAME: CATALOG NUMBER: NOTES: FIXTURE SCHEDULE: Page: 1 of 5 LED HIGH BAY LINEAR ECO SERIES PRODUCT DESCRIPTION: The Eco High Bay Series is a cost-effective and quality solution for lighting warehouses,
More informationSPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System
SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following
More informationSDL4 LED Strip Diffused Lens
Catalog # : Project : Prepared By : Date : SDL4 The sleek architectural SDL is designed with tooless entry features saving time and money on installation. Optimizing industry leading LED technology, the
More informationInstallation Instructions
HB-15NB High Bay Line Voltage Passive Infrared Occupancy Sensors with Nipple Backbox SPECIFICATIONS HB-15NB Power Module Voltages.............................12/277VAC, 6Hz Load Requirements @ 12VAC, 6Hz.............-8W
More informationBALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS
CATALOG NO. TYPE NO. JOB NAME SmarT-Bay 4-Light T8 ORDERING INFORMATION Catalog Number: Example: SBN432EB1-4JP SB N 4 32 EB 1 FIXTURE SB- SmarT- Bay Series Industrials BODY WIDTH N- Narrow (4 Light) LAMPS
More informationCatalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser
Catalog Number FEATURES & SPECIFICATIONS INTENDED USE Built on the compact, low-profile Z strip channel, this LED strip offers long maintenance-free life, several color s, lumen outputs and lengths. Ideal
More informationInstruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier
530 Main Street, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller 442-2 Preamplifier Ver.2.0
More informationUniversal Fan and Light Remote Control
Universal Fan and Light Remote Control Hand-Held Remote and Wall Cradle Owner s Guide and Installation Manual English Form# 41316-01 20100930 2010 Hunter Fan Co. 1 Welcome Table of Contents Read and Save
More informationAs easy as 1, 2, 3. Mark 10 Powerline. Benefits. Features. Application
Lighting As easy as 1, 2, 3 For companies looking to make their fixed-output linear T8, 4-pin CFL, and T5/HO fluorescent systems more cost effective and sustainable, ballasts provide an easy solution without
More informationSECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM
SECTION 260943.13 DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM PART 1 - GENERAL 1.1 SUMMARY LED Lighting Upgrade 26 00 00 1 Digital Network Lighting Controls A. The following
More informationFume Hood Operating Display Panel
Desigo TRA Fume Hood Operating Display Panel QMX3.P87 The Operating Display Panel (ODP) is the interface between the operator and the DXR Fume Hood Controller (FHC). LCD display for volume flow setpoint,
More informationLED RETROFIT CONVERSION KITS
Engineered Products Company s LED RetroFit Conversion Kits convert older 4-foot and 8-foot T8 or T12 strip-type fixtures into energy efficient LED luminaires. High quality components and attractive design
More informationDIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM
DIVISION 26 ELECTRICAL SECTION 26 09 26 PART 1 GENERAL 1.01 DESCRIPTION A. The intent of this set of specifications is to provide a complete, functional, intelligent, lowvoltage lighting control system
More informationEnvironmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current
LED Optimized Drivers 6 Watt Series Model: Series Environmental 6W Designed for use with Triac or ELV Phase Dimmers 120Vac or 230Vac/240Vac. 120Vac Version can be used without dimmer 120/208-277Vac Drive
More informationAlbeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)
Albeo LED Luminaire Heavy Industrial Low Bay Lighting (ALR1 - Series) Product Features The Albeo ALR1-series LED luminaire is an energy-efficient, low maintenance alternative to traditional fluorescent
More informationEvolve LED Garage Light
GE Lighting Evolve LED Garage Light (EG2R) imagination at work Product Features High quality lighting meets long life and controllability with the Evolve LED Garage Light, EG2R. This fixture features an
More informationEL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA
EL7611A/EL7612A Ultrasonic Occupancy Sensors and PRODUCT DATA Proven 30% to 60% utility cost savings because lights are on only when needed. Low initial cost allows fast payback. Models available for 1000
More informationAC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL
AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL October 2003 Revision A Copyright October 2003 VERSITRON, Inc 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com
More informationSECTION INTERIOR LIGHTING
SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationGuide Specification Model CTG Automatic Transfer Switch
Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production
More informationCLS-EXP-DIM. Functional Summary. Specifications
Functional Summary The CLS-EXP-DIM enables the expansion of the Crestron ilux integrated lighting system and other Crestron lighting dimmers to support 120, 230, and 277 volt loads up to 16 amps. It allows
More informationF series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC
echoflex Powered by ETC ER1S-FC Slim Line Dimming Controller F series This guide covers the F series of the Complete Room Controller, model number ER1S-FCU equipped with a 902 MHz radio. The box contents
More informationWallbox Lighting Controls Project Name:
ACCELL Features Electro-mechanical push pad for ON/OFF operation with separate DIM/BRIGHT bar Preset feature allows user to return to previous light setting when turning lights ON Master/Accessory units
More informationTest Report. Appliance EMF Testing
Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is
More informationFR-A180 FR-A360. Occupancy detector. Use
5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable
More informationTLM-1 TOWER LIGHT MONITOR V3.0. INSTALLATION and OPERATING INSTRUCTIONS
TLM-1 TOWER LIGHT MONITOR V3.0 INSTALLATION and OPERATING INSTRUCTIONS SYSTEM OVERVIEW The TLM-1 Tower Light Monitor is a microprocessor-based system designed to monitor the status of incandescent tower
More informationCatalog Number. Notes
Catalog Number FEATURES & SPECIFICATIONS INTENDED USE Built on the compact, low-profile Z strip channel, this LED strip offers long maintenance-free life, several color s, lumen outputs and lengths. Ideal
More informationFixture control made simple
Sensors EasySense Fixture-Mount Fixture control made simple Philips EasySense fixture-mount sensors The easy way to add controls to every fixture As more and more commercial lighting customers look to
More informationelite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems
5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification
More informationUniversal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01
Gamma instabus Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG1 528-1DB01 Technical Product Information Universal Dimmer for switching or dimming of dimmable lamps Supports dimmable lamps including
More informationInstallation Guide IM 1248
Installation Guide IM 1248 BACnet Thermostat for Heat Pump Units Group: Controls Part Number: IM 1248 Date: August 2015 Table of Contents Installation Guide Heat Pump.... 2 Applicable Models... 2 Mounting
More informationFluorescent Dimming Ballast Selection Guide Where to go next: Fluorescent Lighting Controls Selection Guide, pg.196
Fluorescent Dimming Ballast Selection Guide Where to go next: Fluorescent Lighting Controls Selection Guide, pg.96 Lamp Type Lamp Lamps Watts/ per Hi-lume Length Ballast Model # Tu-Wire Model # Eco-0 Model
More informationTHE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:
THE HIGH PERFORMANCE LED Luminaire Series for Stairwells, Bathrooms, Passageways, and General Illumination KEY FEATURES INCLUDE: Multiple Color Options Three color options ensure that the new lighting
More informationLED T8 Tube Standard T8 LED TUBE (L05G-H)
LED T8 Tube Standard T8 LED TUBE (L05G-H) www.ervan.cn Universal Application L05G-H Standard T8 LED TUBE CB [ [ (Applying) Type Approved safety Regular Production Surveillance www.tuv.com ID 200000000
More informationF series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC
echoflex Powered by ETC Complete Room Controller F series ERDRC-FC This guide covers the F series of the Complete Room Controller, model number ERDRC-FCU equipped with a 902 MHz radio. The box contents
More informationWallbox Lighting Controls Project Name:
DEVINE s Features Preset feature allows user to return to previous light level when turning lights ON Integrated full-slide control for easy, precise operation Can be wired as Single-Pole or 3-Way Device
More informationIncentive & Measure Specifications
Incentive & Measure Specifications Commercial Energy Solutions EasySave Program Prescriptive Incentives RETROFIT LIGHTING Incandescent to LED Lighting T12/T8 Fluorescent Tubes to LED Tubes HID to LED Fixtures
More informationCOMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS
COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.895 Date: march 8, 014 Supersedes: 10.895 Date: december 10, 013 1.0 Symbols used in this document 1.0
More informationModel 17A00 Expansion Enclosure
HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number
More informationLED Drivers Designed For Control. Anand Upadhyay LED Systems Rosemont IL
LED Drivers Designed For Control Anand Upadhyay LED Systems Rosemont IL Introduction LED Drivers & Control: 0 10V dimming Driver characteristics w.r.t. dimming AOC Dali Dynadim AmpDim Features Module temperature
More informationApplications. Standard Materials
Mercmaster III Low Profile Compact Fluorescent Luminaires Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors. Applications Enclosed and gasketed fixtures
More informationMotion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels
MS3602CH 2 Channel Motion Sensor For Outdoor Use Wall & Ceiling Mounted Quick & Easy Installation 2 Channels Channel 2 Distance Wiring Diagram 220-240V ~ 50Hz 14A Max. (cosø=1) 3000W for incandescent load
More informationPower Factor (2) 350 ma 90 ~ 132 Vac Vdc 35 W 86% 0.95 LLC-040S035RSP. Efficiency (2)
LLC040SxxxRSP Features Leading Edge and Trailing Edge AC Dimmable Constant Current Output High Efficiency (Up to 86%) Active Power Factor Correction (Up to 0.95) AllAround Protection: SCP and OLP Class
More information2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.
2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T. 418 681-9590 1 800 681-9590 F. 418 681-7393 E. info@cristalcontrols.com cristalcontrols.com TM Index Quick Selection...3-4 Which Technology to use...4 Retrofit
More informationEasyAir SNH200. Sensors. Datasheet. EasyAir SNH200
Sensors EasyAir SNH200 Datasheet EasyAir SNH200 EasyAir SNH200 is the ideal solution for per-fixture control of new light luminaires for high bay applications. It combines occupancy sensing, daylight harvesting
More informationTHE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:
THE HIGH PERFORMANCE LED Luminaire Series for Stairwells, Bathrooms, Passageways, and General Illumination KEY FEATURES INCLUDE: Multiple Color Options Three color options ensure that the new lighting
More informationInstallation Instructions
Fixture Mount Night Light Controller SPECIFICATIONS Power.....................................120VAC, 60Hz Relay Type..................................Form C, N.O. Load Requirements @120VAC......................................500W..........................
More informationPMCSF6 OCCUPANCY SENSOR
PMCSF6 OCCUPANCY SENSOR Lens Main Body Power Cord INTRODUCTION The use of occupancy detectors in commercial and industrial applications can significantly reduce energy usage lessening both energy costs
More informationHOLOPHANE. Enduratron
HOLOPHANE Enduratron Holophane s Elite Series of luminaires brings to the market the introduction of Enduratron. Holophane s electronic HID ballast coupled with the patented ISD SuperGlass has superior
More informationQUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS
QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1-316-832-4357
More informationSAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400
INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400 CAUTION: For safety and proper operation, read and follow instructions carefully before installation. FIELD INSTALLABLE
More informationPump-Up Controller MODEL 4062
Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up
More informationULTRA RT6 and RT6 Gimbal LED Recessed Downlight Kit
www.sylvania.com/rt6 ULTRA RT6 and RT6 Gimbal LED Recessed Downlight Kit Key Features & Benefits Lumen package: 625 lumens @ 11 watts 700 lumens @ 11 watts 900 lumens @ 14 watts Replacement for up to 100W
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL TECHNICAL SYSTEMS (NTS) - LONGMONT 1736 Vista View Drive Longmont, CO 80504-5242 Mr. Eric Loucks Phone: 303 776 7249 ELECTRICAL Valid To: August 31,
More informationECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42
Presence detector ECO-IR 360C NT Art. Nr. 202 0 400 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de instrucciones 62 Istruzioni per l uso 82 Gebruikershandleiding
More information180 Degree Ceiling Mounted Occupancy Sensors
Instruction Bulletin 63249-420-386A 2/202 80 Degree Ceiling Mounted Occupancy Sensors PS-CDS800 and PS-CUS800 INTRODUCTION The 80 Degree Ceiling Mount Occupancy Sensors are ideal for use in business and
More informationMotion Sensor. Specifications
Used for motion activated and dusk to dawn lighting control of flood lights, area lights, etc. Durable weatherproof construction utilizing infrared technology to sense temperature changes caused by movement
More informationSUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM
SUPPLEMENTAL INSTRUCTION SHEET POL-21004-S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM IS21004-S2 24 April 2014 Page 1 of 4 The POL-21004-S2 is a single, steady burning obstruction light with an alarm relay
More informationBooster Power Supply Manual
Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation
More informationEnvironmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range
LED Optimized Drivers Model: Series Environmental 40W Designed for use with Triac or ELV Phase Dimmers 120Vac or 230Vac/240Vac. 120Vac Version can be used without dimmer 120/208-277Vac Drive Mode: PFC
More informationRL with INNOVATOR Doors
Merchandisers K L with INNOVATO Doors Technical Data Sheet /N 042544_M NSF Certified July 200 E Warning: Terminal block NOT for case-to-case wire connection! J A D F G C I H We reserve the right to change
More information[Project Location] SECTION FUSION STAINLESS STEEL DOME HOUSING MOOG VIDEOLARM A&E SPECIFICATION SSDP SERIES
SECTION 28 23 29 FUSION STAINLESS STEEL DOME HOUSING MOOG VIDEOLARM A&E SPECIFICATION SSDP SERIES DIVISION 28- ELECTRONIC SAFETY AND SECURITY 28 20 00 ELECTRONIC SURVEILLANCE 28 23 00 VIDEO SURVEILLANCE
More informationAERS. Automatic Energy Reduction System HID lamp control systems for maximum energy savings
AERS Automatic Energy Reduction System HID lamp control systems for maximum energy savings Holophane has been a leader in energy efficient luminaires and systems for over 100 years. In the late 1960 s,
More informationPump-Down Controller MODEL 4052
Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down
More informationPyroelectric Infrared PIR Motion Sensor Detector ADJ User s Guide
Pyroelectric Infrared PIR Motion Sensor Detector ADJ User s Guide 2004-2009 Sure Electronics Inc. DC-SS502_Ver1.0 Table of Contents Chapter 1. Overview...1 1.1 Preface... 1 1.2 Functions... 1 Chapter 2.
More informationFortimo LED Line High Flux Module
Fortimo LED Line High Flux Module Fortimo LED line 2ft 4000lm 1R LV1 The Fortimo LED Line high flux systems consist of linear white light LED modules with high flux, high energy efficiency, and high quality
More informationDHL-LP-LED Low Profile LED Linear High/Low Bay
Job Information Type: Catalog #: Project: Comments: Prepared by: WARRANTY WARRANTY YEAR TEN INCLUDES LABOR ALLOWANCE 2 65W/90W Version 23.81 2 135W Version For 4 dimensions see pg 2 23.81 23.81 23.81 12.6
More informationHUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004
HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004 EPA Green Lights A L L Y USE OF THIS LOGO DOES NOT IMPLY EPA ENDORSEMENT APRIL 2008 www.nsiindustries.com E-mail: nsi@nsiindustries.com Fax:
More informationUltrasonic Wall Switch Occupancy Sensor Single Circuit
Instruction Bulletin 63249-420-414A1 02/2014 Ultrasonic Wall Switch Occupancy Sensor Single Circuit Commercial Grade with Ground, Single and Multi Location Switching SLSUWS1277C and SLSUWS3277C Retain
More informationTHE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination
THE HIGH PERFORMANCE LED Fixture Series for General, Direct and Indirect Illumination KEY FEATURES INCLUDE: Advanced Thermal Management Industry Leading Deep Fin Heat Sinks with Aircraft Grade Aluminum
More informationUniversal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group. Technical Product Information
Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group Technical Product Information DCL with DEMANDflex DEMANDflex ballasts are high efficiency
More informationAPPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces
Project: Notes: Type: Catalog #: Date: LED UFO HIGHBAY PT-HBA-100W SERIES APPLICATIONS Large Outdoor Large Indoor Industrial Areas Churches Swimming Pools Shopping Malls Warehouses Commercial Gymnasiums
More informationThermo-Sealer. Manual Heat Sealer. User Manual
Thermo-Sealer Manual Heat Sealer User Manual Thermo-Sealer Contents Page Page Introduction 2 Safety 2 Declaration of conformity 3 Caution and safety signs in accordance with IEC 417 4 Unpacking 4 Technical
More informationDual Technology Wall Mounted Occupancy Sensor. Manual & Specification
Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION
More informationInstallation Instructions
Specifications PW-100 PW-200 PW-100/PW-100-347/PW-200/PW-200-347 v3 Passive Infrared Wall Switch Occupancy Sensor PW-100-347 PW-200-347 Voltages: PW-100 & PW-200................ 120/277VAC, 50/60Hz PW-100-347
More information2013 Nonresidential Appendices Appendix NA8-1. Appendix NA8 Luminaire Power... 1 NA8.1 Luminaire Power... 1
2013 Nonresidential Appendices Appendix NA8-1 Nonresidential Appendix NA8... 1 NA8.1 Luminaire Power... 1 NA8.1 Luminaire Power The following tables contain a limited list of lamp and ballast combinations.
More informationCRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1
GREEN LIGHT ARCHITECTURAL DIMMING CONTROLS (GLPD) Crestron Green Light and Green Light Express Network Dimming Control Systems are web accessible, network connected dimming control systems that receive
More information