1 Description PROTEUS Mini-Me is a color graphic display providing Automatic Tank Gauge (ATG) users the freedom to gain access to current tank gauging, leak detectionandalarmstatusfromatgconsoles. AutomaticTankGaugesmonitorstoragevesselsfor level, temperature, volume and potential leaks. Typically,ATG sarelocatedwhereaudiovisualalarms and level information are not conveniently accessible duetoinstallationconstraints.thesetankgaugesare often difficult to use and understand. They are installed in locations that are out of the operator s normalworkareathereforerenderingpotentialalarms unnoticed. PROTEUS Mini-Me allows the user to easily and intuitively gain access to these alarms and level information anywhere throughout a facility. It provides both wired and wireless access to industry standardatg sprovidingeasilyaccessibleinformation whererequired. Universal Remote Display Part Number: Features 7inchcolortouchscreengraphicdisplay Abilitytoviewleaksensoralarmsandtank inventoryremotelyinupto16tanks Audibleandvisualalarms Easytoinstall Easytouse Wallmountorflushmount Wirelessoption AllowsfreedomtolocatemainATGina convenient/economicallocation ConnectstoanyindustrystandardATG Wideviewingangle PatentPending RD7CTS

2 Specifications InputPower: VAC+/10% 50/60Hz25watts (12VDCpoweravailableuponrequest) AudioVisualControls Display: Audiblealarm: Systemstatus: Color7inchgraphicdisplaywithtouchscreen 85dBpiezoelectrichorn 3LED s(ok,warning,alarm) Accessories: WRS232 WirelessRS232linkincludesboth tankgaugeandremotetransceivers WRS232R WirelessRS232repeaterforextending WRS232wirelessreach RDPCK Powercordkit RD232C75 75feetRS232cable C232422RD7CTS RS232422boosterkittoincrease distanceofrs232output ENC4XRD7 NEMA4Xenclosure HTR1 HeaterforNEMA4Xenclosure TEMCS ThermostatforNEMA4Xenclosure Weight: 5lbs. Dimensions: (h)7.63 (w)8.08 (d)3.20 Specificationssubjecttochangewithoutnotice,verifywithmanufacturer. Universal Remote Display -R5- Part No. RD7CTS 1993PondRoad Ronkonkoma,NY11779 Phone: (631) Fax: (631) Website: DocumentNo.DS00028rev1628.doc RevDate: PatentPending

3 WIRED Mechanical Room Remote Display RD7CTS (Located in front office) RS232 Cable RD-232C VAC Power Cord Kit RD-PCK Tank Gauging System OEL8000II shown RD7CTS RD-PCK RD-232C-75 C RD7CTS ENC-4X-RD7 HTR-1 TEM-CS Note: Each item listed above is sold separately. PROTEUS RD7CTS System Parts List PROTEUS Mini-Me TM universal remote ATG monitor with 7" color touch screen display for audio/visual alarms and current inventory. 120 VAC power cord kit for use with PROTEUS remote displays. 75 feet RS232 cable for use with RD7CTS remote display. RS Booster Kit to increase distance of RS-232 output 3,000 feet for use with RD7CTS remote display (Includes 2 converters and 2 power transformers). NEMA 4X enclosure for RD7CTS (may require HTR-1 heater and TEM-CS thermostat if mounting controller outdoors) Heater for NEMA 4X enclosure Thermostat for NEMA 4X enclosure OMNTEC Patent Pending 1993 Pond Road, Ronkonkoma, NY (P) (F) Doc No. DS rev1429.doc

4 WIRELESS Remote Display RD7CTS (Located in front office) Wireless RS232 Link WRS-232 Mechanical Room Wireless RS232 Link WRS RS-232 Cable (included) 75 RS-232 Cable (included) 120 VAC Plug in Xformer (included) Tank Gauging System OEL8000II shown 120 VAC Plug in Xformer (included) 120 VAC Power Cord Kit RD-PCK RD7CTS WRS-232 WRS-232XR WRS-232R RD-PCK PROTEUS RD7CTS System Parts List PROTEUS Mini-Me TM universal remote ATG monitor with 7" color touch screen display for audio/visual alarms and current inventory. Wireless RS-232 link includes both tank gauge and remote transceivers up to 500 feet. Wireless RS-232 link includes both tank gauge and remote transceivers up to one mile. Wireless RS-232 repeater for extending WRS-232 wireless reach additional 500 feet. 120 VAC power cord kit for use with PROTEUS remote displays. Note: Each item listed above is sold separately. OMNTEC Patent Pending 1993 Pond Road, Ronkonkoma, NY (P) (F) Doc No. DS rev1429.doc

5 Description Abrighterfutureintankgaugingandleakdetection has arrived with the PROTEUS Series. Featuring advanced technology, versatility, scalability, and enhanced features like our 7inch color touch screen. The PROTEUS Series can simultaneously monitor product levels, water levels, temperature, leaks, and much more.the flexibility of PROTEUS makes it ideal foravarietyofgaugingandleakdetectionapplications. The OEL8000IIIB is our economical version of the PROTEUSSeries.Itofferslimitedfeaturesforalowcost solution to gauging, leak detection, and meeting compliancerequirements. The OEL8000IIIB accepts up to 16 of OMNTEC s BrightEye(BXSeries)sensorsfordistinguishingproduct from water or for simply detecting the presence of liquid.adistinctadvantageofbrighteyesensorsisthey arenetworkedandutilize4wirebustechnology. PROTEUSdoesnotrequiresensororprobeinput modules,bringingeasetoorderingandinstallation.a builtinmicroprocessorgiveseachsensortheabilityto identifyitselfanditslocation,whichisdisplayedalong with alarm conditions on the PROTEUS s 7inch colortouchscreengraphicdisplay. With OMNTEC s proven reliability, the PROTEUS offers an attractive, comprehensive, and userfriendly systemthatcanopendoorstoendlesspossibilities. PROTEUS Automatic Tank Gauging and Leak Detection System Part Number: Features Acceptsupto4or8magnetostrictiveprobes Acceptsupto16BrightEyesensors Sensorsnetworkedusingstateoftheart 4wirebustechnology 1RS232port 7inchcolorgraphicdisplaywithtouchscreen CITLDupgradeable ExternalModbusdeviceavailable Externalexpansionport Compactsize Remotedisplayoption VLDstandard Lowercost OEL8000III-B4 OEL8000III-B8

6 PROTEUS Automatic Tank Gauging and Leak Detection System -R5- Part No. OEL8000III-B4 & OEL8000III-B8 OEL8000III-B Application Specifications OptionalFeatures: Modbus CITLDupgradeable OMNTECPCsoftware InputPower: VAC+/ 10% 50/60Hz60watts Voltage tosensors: Voltage toprobes: AudioVisualControls: Display: Audiblealarm: Systemstatus: OperatingTemperature: CompatibleSensors: BXSeriesSensorCable: CompatibleProbes: MTGProbeCable: 12VDC 28VDC Color7inchgraphicdisplaywithtouchscreen 85dBpiezoelectrichorn 3LED s(ok,fault,alarm) 20to140 F(7 to60 C) BXSeriessensors (refertodocumentno ) Shielded22AWGwithdrainwire(OMNTECEC4),Maximumlength 2,000feet(610m) Rigid GaugingProbe(refertodocumentno ) MTG4*(1219mm) MTG6*(1829mm) MTG8*(2438mm) MTG10*(3048mm) FlexibleFixedTopProbe(refertodocumentno ) MTGF*Series FlexibleFixedBottomProbe(refertodocumentno ) MTGFB*Series *Numbersignifiesshaftlengthandcorrespondstotankdiameter. Contactrepresentativeforadditionallengths. OMNTECEC2(ShieldedBelden#8761) LowInductance:equalorlessthan.2microhenriesperfoot Maximumlength1,000feet(305m) Consultrepresentativeforlongerwireruns. Accessories: RD7CTS Remotedisplay Weight: Dimensions: Approvals: VersionSummary: 20lb.(9kg) (h)7.73 (w)8.19 (d)5.42 ULlisted&CULlisted Version Probes Sensors Audio/ Visual Relays B yes 0 B8 8 0 yes 0 B4B 4 16 no 0 B8B 8 0 no 0 Specificationssubjecttochangewithoutnotice,verifywithmanufacturer. Comm (1)RS232 (1)ExpansionPort 1993PondRoad Ronkonkoma,NY11779 Phone: (631) Fax: (631) omntec@omntec.com Website: DocumentNo.DS00018DS00026rev1631.doc RevDate:

7 Mini-Me Remote Display RD7CTS RS232 Cable RD-232C-75 PROTEUS-B4 ATG Controller OEL8000IIIB4 120 VAC Power Cord Kit RD-PCK Sump BX-LS or BX-PDS Gauging Probe MTG-* Series Doublewall BX-LWF-* or BX-PDWF-* OEL8000IIIB4 MTG-* BX-LS BX-PDS BX-LWF-* BX-PDWF-* RD7CTS RD-232C-75 RD-PCK C RD7CTS OEL8000IIIB4 System Parts List PROTEUS B4 Tank Gauging Controller with 7" color touch screen and (1) RS-232 port. Accepts up to 4 MTG Series inventory probes and 16 BX Series leak sensors. Magnetostrictive probe (*denotes probe length, price for up to 12 ft.). Sump sensor or doublewall sensor for steel tanks 8 feet and under. (product distinguishing version) Doublewall sensor (*denotes tank diameter). (product distinguishing version) PROTEUS Mini-Me TM universal remote ATG monitor with 7" color touch screen display for audio/visual alarms and current inventory. 75 feet RS232 cable for use with RD7CTS remote display. 120 VAC power cord kit for use with PROTEUS remote displays. RS Booster Kit to increase distance of RS-232 output 3,000 feet for use with RD7CTS remote display (Includes 2 converters and 2 power transformers). OMNTEC 1993 Pond Road, Ronkonkoma, NY (P) (F) Doc No. DS rev1429.doc

8 Mini-Me Remote Display RD7CTS RS232 Cable RD-232C-75 PROTEUS-B8 ATG Controller OEL8000IIIB8 120 VAC Power Cord Kit RD-PCK Gauging Probe MTG-* Series OEL8000IIIB8 MTG-* RD7CTS RD-232C-75 RD-PCK C RD7CTS OEL8000IIIB8 System Parts List PROTEUS B8 Tank Gauging Controller with 7" color touch screen and (1) RS-232 port. Accepts up to 8 MTG Series inventory probes. Magnetostrictive probe (*denotes probe length, price for up to 12 ft.). PROTEUS Mini-Me TM universal remote ATG monitor with 7" color touch screen display for audio/visual alarms and current inventory. 75 feet RS232 cable for use with RD7CTS remote display. 120 VAC power cord kit for use with PROTEUS remote displays. RS Booster Kit to increase distance of RS-232 output 3,000 feet for use with RD7CTS remote display (Includes 2 converters and 2 power transformers). OMNTEC 1993 Pond Road, Ronkonkoma, NY (P) (F) Doc No. DS rev1429.doc

9 Description Abrighterfutureintankgaugingandleakdetection has arrived with the PROTEUS Series.Featuring advanced technology, versatility, scalability, and enhancedfeatureslikeour7inchcolortouchscreen. The PROTEUS-K Series can simultaneously monitor product levels, water levels, temperature, leaks, and much more in up to eight tanks. The flexibilityofproteusmakesitidealforavarietyof gaugingandleakdetectionapplications. The OEL8000IIIK accepts up to 16 of OMNTEC s Bright Eye (BX Series) sensors for distinguishing product from water or for simply detecting the presenceofliquid.adistinctadvantageofbrighteye sensors is they are networked and utilize 4 wire bus technology. PROTEUSdoesnotrequiresensororprobeinput modules,bringingeasetoorderingandinstallation.a builtinmicroprocessorgiveseachsensortheabilityto identifyitselfanditslocation,whichisdisplayedalong with alarm conditions on the PROTEUS s 7inch colortouchscreengraphicdisplay. WithOMNTEC sprovenreliability,theproteus offersanattractive,comprehensive,anduserfriendly systemthatcanopendoorstoendlesspossibilities. PROTEUS Automatic Tank Gauging and Leak Detection System Features Part Number: Acceptsupto8magnetostrictiveprobes Acceptsupto16BrightEyesensors Sensorsnetworkedusingstateoftheart 4wirebustechnology 1RS232port 1RS485port(optional) 7inchcolortouchscreengraphicdisplay Largeuserfriendlyicons Easytoreadleakandlevelalarms SDmemorycardslot(forextendedlogging) CITLDupgradeable ModbusRTU&TCPupgradeable Ethernet/TCP/IPstandard Builtinwebserver /Textcapabilitystandard SILratedoperatingsystem Remotedisplayoption Thermalprinteroption VLDstandard 3builtinprogrammablerelays Upto8additionaldrycontactrelays Flashbasednonvolatilememoryforprogram storage(doesnotrequireabattery) CompatiblewithOMNTECPCremote tankinventorymonitoring OEL8000IIIK4 OEL8000IIIK8

10 PROTEUS Automatic Tank Gauging and Leak Detection System -R5- Part No. OEL8000IIIK4 & OEL8000IIIK8 OEL8000III-K Application Specifications OptionalFeatures: 36characterthermalprinter CITLDupgradeable ModbusRTUandTCP OMNTECPCsoftware InputPower: Voltage tosensors: Voltage toprobes: AudioVisualControls: Display: Audiblealarm: Printer: Systemstatus: RelayOutputs: LowvoltageOutputs: OperatingTemperature: CompatibleSensors: BXSeriesSensorCable: VAC+/ 10%50/60Hz60watts 12VDC 28VDC Color7inchgraphicdisplaywithtouchscreen 85dBpiezoelectrichorn 36characterthermal 3LED s(ok,warning,alarm) ampresistive3spstfailsafe 20to140 F(7 to60 C) BXSeriessensors (refertodocumentno ) Shielded22AWG withdrainwire(omntecec4) Maximumlength2,000feet(610m) CompatibleProbes: RigidGaugingProbe(refertodocumentno ) MTG4*(1219mm) MTG6*(1829mm) MTG8*(2438mm) MTG10*(3048mm) FlexibleFixedTopProbe(refertodocumentno ) MTGF*Series FlexibleFixedBottomProbe(refertodocumentno ) MTGFB*Series *Numbersignifiesshaftlengthandcorrespondstotankdiameter. Contactrepresentativeforadditionallengths. MTGProbeCable: OMNTECEC2(ShieldedBelden#8761) LowInductance:equalorlessthan0.2microhenriesperfoot Maximumlength1,000feet(305m) Consultrepresentativeforlongerwireruns. Accessories: RD7CTS MiniMeremotedisplay RASSeries Remoteannunciators PS103 Thermalprinter DPUC Thermalpaper XCR8 Externalrelayexpansion X ExternalRS232to420maconverter DB485 RS485board Weight: 20lb.(9kg) Dimensions: Approvals: VersionSummary: (h)7.73 (w)15.21 (d)5.53 ULlisted&CULlisted Version Probes Sensors Audio/ Visual Relays K yes 3 K8 8 0 yes 3 K4B 4 16 no 3 K8B 8 0 no 3 Specificationssubjecttochangewithoutnotice,verifywithmanufacturer. Communication (1)RS232 (1)TCP/IP (1)Expansion Port (1)SDCard slot 1993PondRoad Ronkonkoma,NY11779 Phone: (631) Fax: (631) omntec@omntec.com Website: DocumentNo.DS00014DS00015rev1631.doc RevDate:

11 Overfill Alarm RAS-1-NYS Mini-Me Remote Display RD7CTS RS232 Cable RD-232C-75 PROTEUS-K4 ATG Controller OEL8000IIIK4P 120 VAC Power Cord Kit RD-PCK Sump BX-LS or BX-PDS Gauging Probe MTG-* Series Doublewall BX-LWF-* or BX-PDWF-* OEL8000IIIK4 OEL8000IIIK4P MTG-* BX-LS BX-PDS BX-LWF-* BX-PDWF-* RAS-1-NYS RD7CTS RD-232C-75 RD-PCK C RD7CTS OEL8000IIIK4 System Parts List PROTEUS K4 Tank Gauging Controller with 7" color touch screen, (1) RS-232 port, & Ethernet. Accepts up to 4 MTG Series inventory probes and 16 BX Series leak sensors. (same as above but includes printer) Magnetostrictive probe (*denotes probe length). Sump sensor or doublewall sensor for steel tanks 8 feet and under. (product distinguishing version) Doublewall sensor (*denotes tank diameter). (product distinguishing version) Common overfill remote annunciator in Nema 4X enclosure, with acknowledgement switch, 100db horn, and high intensity strobe light. PROTEUS Mini-Me TM universal remote ATG monitor with 7" color touch screen display for audio/visual alarms and current inventory. 75 feet RS232 cable for use with RD7CTS remote display. 120 VAC power cord kit for use with PROTEUS remote displays. RS Booster Kit to increase distance of RS-232 output 3,000 feet for use with RD7CTS remote display (Includes 2 converters and 2 power transformers). OMNTEC 1993 Pond Road, Ronkonkoma, NY (P) (F) Doc No. DS rev1429.doc

12 Mini-Me Remote Display RD7CTS RS232 Cable RD-232C-75 PROTEUS-K8 ATG Controller OEL8000IIIK8P 120 VAC Power Cord Kit RD-PCK Gauging Probe MTG-* Series OEL8000IIIK8 OEL8000IIIK8P MTG-* RD7CTS RD-232C-75 RD-PCK C RD7CTS OEL8000IIIK8 System Parts List PROTEUS K8 Tank Gauging Controller with 7" color touch screen, (1) RS-232 port and Ethernet. Accepts up to 8 MTG Series inventory probes. (same as above but includes printer) Magnetostrictive probe (*denotes probe length, price for up to 12 ft.). PROTEUS Mini-Me TM universal remote ATG monitor with 7" color touch screen display for audio/visual alarms and current inventory. 75 feet RS232 cable for use with RD7CTS remote display. 120 VAC power cord kit for use with PROTEUS remote displays. RS Booster Kit to increase distance of RS-232 output 3,000 feet for use with RD7CTS remote display (Includes 2 converters and 2 power transformers). OMNTEC 1993 Pond Road, Ronkonkoma, NY (P) (F) Doc No. DS rev1429.doc

13 Description A brighter future in tank gauging and leak detection has arrived with the PROTEUS Series.Featuring advanced technology, versatility, scalability, and enhancedfeatureslikeour7inchcolortouchscreen. The PROTEUS-X Series can simultaneously monitor product levels, water levels, temperature, leaks,andmuchmoreinupto16tanks.theflexibility ofproteusmakesitidealforavarietyofgaugingand leakdetectionapplications. The OEL8000IIIX accepts up to 64 of OMNTEC s Bright Eye (BX Series) sensors for distinguishing product from water or for simply detecting the presenceofliquid.adistinctadvantageofbrighteye sensors is they are networked and utilize 4 wire bus technology. PROTEUSdoesnotrequiresensororprobeinput modules,bringingeasetoorderingandinstallation.a builtinmicroprocessorgiveseachsensortheabilityto identifyitselfanditslocation,whichisdisplayedalong with alarm conditions on the PROTEUS s 7inch colortouchscreengraphicdisplay. WithOMNTEC sprovenreliability,theproteus offersanattractive,comprehensive,anduserfriendly systemthatcanopendoorstoendlesspossibilities. PROTEUS Automatic Tank Gauging and Leak Detection System Features Part Number: Acceptsupto16magnetostrictiveprobes Acceptsupto64BrightEyesensors Sensorsnetworkedusingstateoftheart 4wirebustechnology (1)RS232port (1)RS485port 7inchcolortouchscreengraphicdisplay Largeuserfriendlyicons Easytoreadleakandlevelalarms SDmemorycardslot(forextendedlogging) CITLDupgradeable ModbusRTU&TCPupgradeable Ethernet/TCP/IPstandard Builtinwebserver /Textcapabilitystandard SILratedoperatingsystem Remotedisplayoption Thermalprinteroption VLDStandard 3builtinprogrammablerelays Upto32additionaldrycontactrelays Flashbasednonvolatilememoryforprogram storage(doesnotrequireabattery) CompatiblewithOMNTECPCremote tankinventorymonitoring OEL8000IIIX

14 PROTEUS Automatic Tank Gauging and Leak Detection System -R5- Part No. OEL8000IIIX OEL8000IIIX Application Specifications OptionalFeatures: 36characterthermalprinter ModbusRTUandTCP CITLDupgradeable OMNTECPCsoftware InputPower: VAC+/10% 50/60Hz50watts(optional12VDCpower) PowertoSensors: PowertoProbe: 28VDC AudioVisualControls: Display: Audiblealarm: Printer: Systemstatus: Color7inchgraphicdisplaywithtouchscreen 85dBpiezoelectrichorn 36characterthermal 3LED s(ok,fault,alarm) BuiltInRelayOutputs: 3SPSTFailsafe LowvoltageOutput: OperatingTemperature: 20to140 F(7 to60 C) CompatibleSensors: BXSeriessensors(refertodocumentno ) BXSeriesSensorCable: Shielded22AWGwithdrainwire(OMNTECEC4) Maximumlength2,000feet(610m) CompatibleProbes: RigidGaugingProbe(refertodocumentno ) MTG4*(1219mm) MTG6*(1829mm) MTG8*(2438mm) MTG10*(3048mm) FlexibleFixedTopProbe(refertodocumentno ) MTGF*Series FlexibleFixedBottomProbe(refertodocumentno ) MTGFB*Series *Numbersignifiesshaftlengthandcorrespondstotank diameter.contactrepresentativeforadditionallengths. MTGProbeCable: OMNTECEC2(ShieldedBelden#8761) LowInductance:equalorlessthan0.2microhenriesperft. Maximumlength1,000feet(305m) Consultrepresentativeforlongerwireruns. Accessories: RD7CTS MiniMeremotedisplay RASSeries Remoteannunciators PS103 Thermalprinter DPUC Thermalpaper XB416 4probe16leaksensoroutputboard XB400 4probeoutputboard XBRB8 8relayoutputboardratedat5amps120VAC Weight: 20lb.(9kg) Dimensions: (h)7.75 (w)15.25 (d)8.78 Depthdimensionincludesprinterandbezel Approvals: ULlisted&CULlisted Specificationssubjecttochangewithoutnotice,verifywithmanufacturer. 1993PondRoad Ronkonkoma,NY11779 Phone: (631) Fax: (631) Website: DocumentNo.DS00020rev1631.doc RevDate:

15 Overfill Alarm RAS-1-NYS Mini-Me Remote Display RD7CTS RS232 Cable RD-232C-75 PROTEUS-X ATG Controller OEL8000IIIXP 120 VAC Power Cord Kit RD-PCK Sump BX-LS or BX-PDS Gauging Probe MTG-* Series Doublewall BX-LWF-* or BX-PDWF-* OEL8000IIIXP XB-416 XB-RB8 MTG-* BX-LS BX-PDS BX-LWF-* BX-PDWF-* RAS-1-NYS RD7CTS RD-232C-75 RD-PCK C RD7CTS OEL8000IIIXP System Parts List PROTEUS X Tank Gauging Controller with 7" color touch screen, printer, (1) RS-232 port, & Ethernet. Accepts up to 16 MTG Series inventory probes and 64 BX Series leak sensors. 4 probe and 16 leak sensor module for OEL8000IIIX. 8 channel relay board for OEL8000IIIX. Magnetostrictive probe (*denotes probe length). Sump sensor or doublewall sensor for steel tanks 8 feet and under. (product distinguishing version) Doublewall sensor (*denotes tank diameter). (product distinguishing version) Common overfill remote annunciator in Nema 4X enclosure, with acknowledgement switch, 100db horn, and high intensity strobe light. PROTEUS Mini-Me TM universal remote ATG monitor with 7" color touch screen display for audio/visual alarms and current inventory. 75 feet RS232 cable for use with RD7CTS remote display. 120 VAC power cord kit for use with PROTEUS remote displays. RS Booster Kit to increase distance of RS-232 output 3,000 feet for use with RD7CTS remote display (Includes 2 converters and 2 power transformers). OMNTEC 1993 Pond Road, Ronkonkoma, NY (P) (F) Doc No. DS rev1429.doc

16

17 Magnetostrictive Tank Gauging Probe Part Number: MTG-4 MTG-6 MTG-8 MTG-10 Description The magnetostrictive tank-gauging (MTG) probe utilizes magnetostrictive technology to provide users with the same level of reliability, durability and costeffectiveness they expect with all OMNTEC products. The MTG probe used with OMNTEC s tank gauging controllers monitors product levels, water levels and temperature in both underground and aboveground tank applications. The MTG probe monitors the following conditions: high-product level, low-product level and high-water level. To provide the greatest flexibility of use, the probe s shaft is stainless steel and the floats are available in a variety of materials and sizes. Other major benefits of OMNTEC s MTG probe is that it comes in a number of lengths and in a flexible-shaft option. The number in the probe part number indicates the shaft length and corresponds to tank diameter. The MTG probe is ruggedly constructed to provide reliable and cost-effective performance. Features Patented reflection technique for reliability Durable tube-in-tube construction High signal-to-noise ratio Fast, accurate update Float options Custom lengths Intrinsically safe Cost-effective Flexible shaft (optional)

18 Magnetostrictive Tank Gauging Probe Part No. MTG-* Specifications Enclosure (probe): NEMA 4, IP68 Input Power: 28 VDC +/-10% Probe Length: Accuracy: Linearity Repeatability: Temperature Measurement: Temperature Accuracy: Temperature Measurement Resolution: Temperature Sensing Range: Operating Temperature Range: Probe Output: Distance to Monitor: Pressure Rating: Floats: Compatible Controllers: MTG includes: Weight: Up to 24 feet (7.3m) Consult factory for lengths over 24 feet inches (0.2540mm) inventory mode inches (0.0254mm) leak-detection mode +/- 0.01% of full scale or +/ inches (0.254mm), whichever is greater +/ % of full scale or +/ inches (.00635mm), whichever is greater 6 temperature-sensing devices +/- 0.9 F from 14 F to +185 F +/- 0.5 C from -10 C to +85 C +/ F ( C) -40 to 150 F (-40 C to 66 C) -40 to 160 F (-40 C to 71 C) Digital over 2 wires Probe cable must be EC-2 (Belden #8761) up to 1,000 feet (305m). Consult factory for lengths over 1,000 feet. Up to 500 psi (35Kg/cm2)(float-dependent) Specs based on 4-inch standard OEL8000 & OEL8000II PROTEUS Series: OEL8000III-B, OEL8000III-K, OEL8000III-X 4-inch Buna N float kit 4-inch cap Splice kit Cable assembly 19 lb. (8.62 kg) (approximated based on packaged 10ft. probe) Accessories: SL-34 Swage lock (probe-head isolation for chemical applications) SSF inch (97.79mm) stainless-steel float kit SSF inch (46.48mm) stainless-steel float kit BNF inch (97.79mm) Buna N float kit UF inch (72.39mm) urethane float kit Specifications subject to change without notice, verify with manufacturer. OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No rev1-3.doc Rev Date:

19 OMNTEC Bright Eye Sensors BX-Series Part Numbers: BX-PDS BX-PDWS BX-PDWF BX-LS BX-LWF BX-RES BX-L-SERIES Description OMNTEC sensors are most known for their ease of installation, reliability, cost effectiveness and their ability to be tested remotely. Bright Eye sensors (BX-series) are self diagnostic, and programmed to identify themselves and their location, providing the user with critical information. Each sensor can recognize its unique serial number, part number and function. It accomplishes this via an internal microprocessor that enables it to distinguish itself from the other sensors on the system. This information is then relayed back to the OEL8000II controller, eliminating the need to guess where a leak condition is occurring. Built with four wire buss technology, up to 22 Bright Eye (BX-series) sensors can be networked along a common cable. (A total of 44 Bright Eye sensors can be used with the OEL8000II.) This eliminates the need to run separate lines for every sensor, which results in fewer conduits, and a quicker, less expensive and easier installation. In addition, systems already installed can be easily retrofitted without the need to run new cable. A major feature of these sensors is that they can be tested from a remote location with the press of a single button, which has been third party certified. Features Self identifying by part number, serial number and function Self diagnostic Easily installed Minimal conduit needed Minimal programming required Product distinguishing or liquid only detection Easily tested without removal Corrosion resistant Not affected by hydrocarbon vapors or condensation Intrinsically safe Detects liquids at any angle No moving parts Modified sensors available Cost effective Third party certified UL listed, CUL listed, CE listed

20 Product-Distinguishing Leak-Detection Sensors The OMNTEC BX-series product distinguishing sensors employ proven optic technology for leak detection coupled with the principle of conductivity to distinguish between product and water. An internal microprocessor enables the BX-series sensors to be self diagnostic and self identifying. Each sensor can recognize its serial number, part number and function. This allows the controller to differentiate one sensor from another on the network and relay critical information to the user. BX-PDS General Purpose Sensor The BX-PDS was designed to accommodate a variety of applications. With its convenient size and ability to detect liquids at any angle, the BX-PDS sensor is the ideal sensor for sumps, dispenser pans and containment areas. BX-PDWS Sensor for Double-Wall Steel Tanks & 1-5/8" Diameter Xerxes 4 -Diameter Dry Double-Wall Fiberglass Tanks The BX-PDWS was designed to fit into the annular space of 3/4" steel double-wall tanks. It can Strain Relief distinguish liquid hydrocarbons from water, and, like all BX-series sensors, can be remotely tested without removal. 3/4" NPT NIPPLE 3" 3" Cable Length 12 Feet Cable Length 20 Feet 3/4" NPT NIPPLE Bright Eye Microprocessor LED Principles of Operation for BX-PDS and BX-PDWS Prism Dry condition Wet Condition LED Detector Conductivity Electrode Electrical Conductance BX-PDWF Sensor for Dry Double-Wall Fiberglass Tanks The BX-PDWF was designed to fit into the annular space of dry double-wall fiberglass tanks. It can distinguish liquid hydrocarbons from water, and, like all 18" BX-series sensors, can be remotely tested without removal. With its slim, compact shape and flexible snake like shaft, the BX-PDWF can easily be installed diameter and removed from grade. (When ordering, the part number will denote tank diameter.) Sized to tank 1-5/8" Diameter Cable length 20 feet Bright Eye Microprocessor Principles of Operation for BX-PDWF LED Prism Dry condition Wet Condition LED Detector Conductivity Electrode Electrical Conductance 1-5/8" 5/8"

21 Non-Distinguishing Leak-Detection Sensors OMNTEC BX-series non-distinguishing sensors employ proven optic technology for leak detection applications. An internal microprocessor enables these sensors to be self diagnostic and self identifying. Each sensor can recognize its serial number, part number and function. This allows the controller to differentiate one sensor from another on the network and relay critical information to the user. BX-LS General Purpose Sensor Sensor for Double-Wall Steel Tanks & Xerxes 4 -Diameter Dry Double-Wall Fiberglass Tank The BX-LS non-distinguishing sensor was designed to accommodate a variety of applications. With its convenient size and ability to detect liquids at any angle, the BX-LS sensor is the ideal sensor for sumps, dispenser pans, containment areas and annular spaces of double-wall steel tanks. 3/4" NPT NIPPLE 3" Cable Length 12 Feet Bright Eye Microprocessor LED Principles of Operation for BX-LS Prism Dry condition LED Detector BX-LWF Sensor for Dry Double-Wall Fiberglass Tanks The BX-LWF non-distinguishing sensor was designed to fit into the annular space of dry double-wall fiberglass tanks. With its slim, compact shape and flexible snake like shaft, the BX-LWF can easily be installed and removed from grade. (When ordering, the part number will denote tank diameter.) 18" Sized to tank diameter 1-5/8" Diameter Cable length 20 feet Bright Eye Microprocessor LED Wet Condition Principles of Operation for BX-LWF Prism Dry condition LED Detector 1-5/8" 5/8" Wet Condition

22 Leak-Detection Sensors for Other Applications BX-RES Sensor for Brine-Filled Double-Wall Tanks The dual point BX-RES sensor is designed for double-wall brine filled fiberglass tanks. This sensor is made of nonmetallic corrosion resistant materials. An alarm is activated to signal changes in reservoir liquid level beyond acceptable limits (high or low). Cable Length 20 Feet 16.00" 13.00" BX-L-Series Product-Level Sensor The BX-L-series sensors are designed to provide product level alarms for high, caution or low product levels. BX-L-series sensors can be remotely tested without removal. This sensor is available with multiple alarm points. 3/4" NPT 2" NPT D" Cable Length 3 Feet Length should be specified in inches by user 2" 2.75" 1-5/8" 5/8" Specifications for BX-Series Sensors Power Consumption: Sensor Cable: Principles of Operation: Normal Condition: Alarm Condition: (refracts) Water Condition (BX-PDS, BX-PDWS and BX-PDWF only): ma Shielded 22 AWG with drain wire (OMNTEC EC-4) Maximum length 2,000 feet Normally closed beam of light Normally closed beam of light opens Conductivity electrode Bright Eye Microprocessor Principles of Operation for BX-RES and BX-L-Series LED Prism Dry condition LED Detector Response Time: Operating Temperature: *Compatible System: Immediate -15 to 140 F OEL8000II PROTEUS Series OEL8000III-B, OEL8000III-K, OEL8000-X Wet Condition Approvals: UL listed, CUL listed, CE listed Note: Current published specifications are subject to change without notification. Verify specifications with manufacturer. *Please consult factory for additional compatible controllers. For technical information: OMNTEC OMNTEC Mfg., Inc Pond Road Ronkonkoma, New York Phone: Fax: omntec@omntec.com Web Site: Doc Rev1-1 Date:

23 Description Available on firmware version 4.50 and higher for OEL8000II. Features Remote Annunciators Part Number: RAS Series

24 Remote Annunciators Part No. RAS Series -FB-R5-XXX Specifications PROTEUS PROTEUS Specifications subject to change without notice, verify with manufacturer. RAS-1 RAS-2 RAS-3 RAS-4 OMNTEC OMNTEC OMNTEC OMNTEC RAS-1-NYS

25 Remote Display Part Number: RD625 Series Description The RD625 LED series remote display can be used in applications where tank level must be displayed in remote locations up to 2000 away from the OEL8000II controller. RD625 is available for multiple tanks with individual displays for each tank. The RD625 comes standard in a NEMA 4x enclosure to allow it to be mounted outdoors. This remote display can be customized with individual LED lights for alarm indications as well as an audible horn. Consult factory for pricing and part numbers. Specifications Power Input 120VAC Weight and Dimensions 10lbs. (W) 9 x (H) 10 x (D) 6.25 Enclosure TYPE 4X Operating Temperature 0º to 50º C Display 6 digit, 0.56 red LED sunlight readable display for tank volume Input RS-485 from OEL8000II Wire 3 wire 22 awg shielded cable (comes with 10 wire and 9 pin connector) Specifications subject to change without notice, verify with manufacturer.

26 Remote Display Part No. RD625 Series GALLONS DSP PAR F1 F2 RST TANK #1 RD625-1 shown Wiring from RD625-* to OEL8000II RS-485 Inside Remote Display OEL8000II FUSE BLACK WHITE RED WARNING: THIS TERMINAL MUST BE F.G. L N Cables from RS-485 port in OEL8000II 9-PIN Male Dsub Connector OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r121908

27 Temperature Sensor Part Number: BX-TC-1 Description OMNTEC sensors are most known for their ease of installation, reliability, cost-effectiveness and their ability to be tested remotely. Bright Eye sensors (BX-series) are self-diagnostic, and programmed to identify themselves and their location, providing the user with critical information. The BX-TC-1, temperature sensor, was designed to monitor temperatures ranging from - 50 to 150 C with an accuracy of 1 C. C-store and hypermarket owners can now monitor their air temperature in kiosks, refrigeration and freezers with the same 4-wires being used to monitor their fuel tanks. Owners can now be forewarned if the temperature of their refrigeration goes out of range, preventing inventory loss. High and low temperature alarm points are fully user programmable notifying the user when equipment is operating inefficiently. The BX-TC-1 sensor can recognize its unique serial number, part number and function. It accomplishes this via an internal microprocessor that enables it to distinguish itself from the other sensors on the system. This information is then relayed back to the OEL8000II controller, eliminating the need to guess where the alarm condition is occurring. Built with four-wire buss technology, up to 22 Bright Eye (BX-series) sensors can be networked along a common cable. (A total of 44 Bright Eye sensors can be used with the OEL8000II). This eliminates the need to run separate lines for every sensor, which results in fewer conduits, and a quicker, less expensive and easier installation. In addition, systems already installed can be easily retrofitted without the need to run new cable. A major feature of these sensors is that they can be tested from a remote location with the press of a single button. According to the FDA refrigerators should stay at 41 F (5 C) or less. A temperature of 41 F (5 C) or less is important because it slows the growth of most bacteria. The temperature won't kill the bacteria, but it will keep them from multiplying, and the fewer there are, the less likely you are to get sick from them. Freezing at zero F (minus 18 C) or less stops bacterial growth (although it won't kill all bacteria already present). Features Range: -50 to +150 C Accuracy of 1 C Temperature control capability Programmable high and low temp. alarms OMNTEC PC Compatible Self-identifying by part number, serial number and function Self-diagnostic Easily installed Minimal conduit needed Minimal programming required Easily tested without removal Corrosion resistant Modified sensors available Cost-effective

28 Temperature Sensor MTG-FB-R5-XXX Part No. BX-TC-1 BX-TC-1 Sensing Element Wires to network Universal Translator Specifications Power Consumption 1.4mA Sensor Cable Shielded 22AWG with drain wire (OMNTEC EC-4) Maximum length 2,000 feet Sensing Element Operating -50 to 150 C Temperature Electronics Operating Temperature -15 to 140 F (Universal translator) Compatible Systems OEL8000II Applications Refrigeration Freezers Compressors Room Temperature Specifications subject to change without notice, verify with manufacturer. BX-TC-1 Installation Junction box to next sensor (up to 22 sensors per buss) twisted drains from OEL8000II controller or previous sensor on buss use SK-3 kit to seal connection OMNTEC PC displays readings from TC-1 sensor on your PC to temperature sensing point With temperature control equipment temperature ranges can be set and monitored through OMNTEC PC BX-TC-1 Dimensions 20ft in. 3ft OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r121108

29 OMNTEC Ethernet Interface Board IB-NET-3 NOW SENDS MAIL TO CELL PHONE OR Features High performance 10/100BaseT Ethernet IEEE Allows for real-time data retrieval Allows the user to access site information from any location at anytime without having to spend money on on-site visits Allows user to program or change system parameters remotely If used with OMNTECPC software (OMN-PC) user can track and log tank information in a database Unlimited access to any number of sites Sends alarms, drop reports, VLD reports and shift reports to or cell phone The OMNTEC IB-NET-3 Ethernet board is a complete, ready to integrate serial-to-ethernet module for connecting the OEL8000II console to an IP network for remote monitoring, control and configuration. Specifications Serial port: Baud: 57.6K Data: 8 Parity: N Stop: 1 Flow-Control: None Operating Temp: 0 to +70 F humidity range 20-90% (non-condensing) Power Usage: 10mbps Typical 240mA Maximum 280mA 100mbps Typical 270mA Maximum 310mA Programming: OMNTEC PC version 5.0 and higher OEL8000II version 9.08 or higher TTY (ex. Hyperterminal) Telnet client Weight: Connection: 1 lb. Standard Ethernet RJ45 Note: Current published specifications are subject to change without notification. Verify specifications with manufacturer. OMNTEC Mfg., Inc., 1993 Pond Road, Ronkonkoma, NY Phone (631) Fax (631) File Name: rev1-1.doc Page 1 of 1 Rev: 1.1 Rev Date:

30

31 Flexible MTG Probe For Tank Inventory Monitoring Part Number: MTG-F-XXX Description The MTG stick flex probe takes field proven magnetostrictive technology and packages it in a revolutionary new way for greater reliability, easy installation, and mounting. The MTG-F-XXX (where XXX is the overall probe length in inches) is ideal for liquid level monitoring of product and interface level in a wide variety of liquid media in both above ground and below ground storage tanks. All electronics are integrated into a 5/8 diameter Kynar sensing tube. The MTG-F-XXX is equipped with a threaded fitting and 6 cable. This break through in package design eliminates the bulky electronics enclosure at the top of the probe and offers you greater options for insertion and mounting in tanks and vessels. The MTG-F-XXX employs a flexible Kynar housing and provides a cost effective level monitoring in deep tanks. The MTG-F-XXX s lower cost design provides more options, offers savings on installation and mounting and has the ultimate in designed-in reliability. Features Low-cost Magnetostrictive Design with Electronics Integrated into 5/8 Sensing Tube High Resolution and Accuracy UL, Intrinsically Safe Flexible Kynar Float Options No Calibration Required Proven Magnetostrictive Sensing Performance in a Revolutionary New Package!

32 Flexible MTG Series Probes MTG-FB-R5-XXX Part No. MTG-F-XXX Specifications Input Voltage Vdc Probe Length Up to 70 Resolution Inventory Mode Linearity +/- 0.01% of full scale +/ ,whichever is greater Repeatability +/ % of full scale +/ ,whichever is greater Temperature Up to five along the probe span Measurement Temperature accuracy, +/- 2ºF Absolute Temperature +/ ºF Measurement, Resolution Temperature Sensing -40ºF to +150ºF Range Operating Temperature -40ºF to + 160ºF Range Probe Output Pulse Position Modulated Digital Distance to Monitor 1000 using Belden 8761 Deadband / Null see dimension Approval Sheet Compatible Controllers: OEL8000II PROTEUS Series OEL8000III-B, OEL8000III-K, OEL8000III-X Floats Specs based on 4 standard urethane (consult factory for float options) Listings UL, Intrinsically safe when used in accordance with OEL8000II control drawing Bend Radius Not to exceed 3 during installation Specifications subject to change without notice, verify with manufacturer. 1/2 MNPT 3/4 MNPT *Final Probe Tank Fitting 3/4 FNPT Float Stop Product Float Float Options Weight / Spacer 4 Buna Float Part No. BNF-4 BNF-1-4 (product float only) 2 Stainless Steel Part No. SSF-2 SSF-1-2 (product float only) 4 Stainless Steel Float Part No. SSF-4 SSF-1-2 (product float only) Note: For dual float probes with overall length greater than 288, a float spacer will be required between two floats. Weight Dimensions W2 Series Weight Overall Length Weight Part No. Dimensions (2 diameter) Weight or Spacer Up to 144 W (h) Spacer W (h) Weight W (h) Weight W (h) Weight W (h) Weight W (h) Weight W2 Series Weight OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No rev1-1.doc Rev. Date:

33 Flexible Fixed Bottom MTG Probe For Tank Inventory Monitoring Part Number: MTG-FB-R5-XXX COMPENSATE FOR ROOF MOVEMENT UNPARALLELED INVENTORY ACCURACY ACCURATE TEMPERATURE COMPENSATION MEASURE AS LOW AS 1 OF WATER OFF TANK BOTTOM ALL FROM ONE TANK OPENING ALL WITHOUT TAKING YOUR TANK OUT OF SERVICE! Description MTG-FB-R5-XXX (where XXX is the overall probe length in inches, from 209 to 860 ) is a flexible PVDF magnetostrictive tank inventory management probe which enables very accurate product level and measurement of as little as 1 (25mm) of water in the bottom of tanks. It also provides five temperature measurements spaced evenly 1m from the tank floor. The MTG-FB-R5-XXX benefits from a bottom reference approach by resting a heavy hollow weight on the bottom of each tank. This unique OMNTEC bottom reference design takes full advantage of the tank bottom stability versus known instabilities of a tank roof. The tank bottom reference design is further enhanced by a top mounted constant tension feature. This feature maximizes the probe s level accuracy to less than 0.01 of an inch by removing tank movements and its influence on measurement. In turn this OMNTEC exclusive design maximizes the operator s ability to manage inventory with accuracy and confidence. The MTG-FB-R5-XXX is typically installed on a 6 or larger process fitting. Other fitting may be accommodated. Please consult the factory for a detailed review of your unique application. Numerous product float options are available, dependent on the density and composition of the tank product.

34 Flexible Fixed Bottom MTG Series Probes MTG-FB-R5-XXX Part No. MTG-FB-R5-XXX Spring Rod Cap Cover Tube Specifications Part No. MTG-FB-R5-XXX Input Voltage VDC Overall Probe Length 209 to 860 Enclosure Rating PVDF, IP 68 Typical Level Resolution Linearity +/- 0.01% of Full Scale +/ , whichever is greater Repeatability +/ % of Full Scale +/ , whichever is greater Temperature Up to 5 along the sensor span Measurement Temperature Accuracy, +/- 2 F Absolute Typical Temperature +/ F Resolution Temperature Sensing -40 F to +158 F or Range -40 C to 70 C Operating Temperature -40 F to +158 F or Range -40 C to 70 C Probe Output Pulse Position Modulation Distance to Monitor 1000 using Belden 8761 Compatible Controllers OEL8000II OEL8000II PROTEUS Series OEL8000III-B, OEL8000III-K, OEL8000III-X Floats BNF Buna Product Float SSF Stainless Steel Product Float SSF Stainless Steel Product Float SSF-1-2W-VB 2 Stainless Steel Water Float for low water detection applications (used with W6-VBH weight) SSF-1-2-VB 2 Stainless Steel Product Float for low product detection applications (used with W6-VBH weight) Specs based on 4 buna Weight W6-VBH 5.75 (dia) x 7 (h) Stainless Steel Weight for use in low water or product applications when used in conjunction with floats SSF-1-2W-VB and SSF-1-2-VB. Requires a 6 accessible opening on tank top. Spacer SFS Stainless Steel Float Spacer required on probe lengths 288 or greater Listings UL, Intrinsically safe when used in accordance with OEL8000II control drawing Specifications subject to change without notice, verify with manufacturer. Cable 2 Cond. 22 AWG Belden or Equiv. 7.5 long Support Rods Tank Coupling ½ NPT (for conduit) *Final Probe Tank Fitting 2 FNPT dia. Flexible PVDF shaft Product Float (BNF-1-4 shown) Spacer (SFS shown) Interface Float (SSF-1-2W-VB shown) Weight (W6-VBH shown) Rests on tank floor Float Options Part No. BNF-1-4 Part No. SFS Part No. SSF-1-4 Part No. SFS Part No. SSF-1-2 Part No. SFS Part No. SSF-1-2W-VB Part No. SSF-1-2W-VB Part No. SSF-1-2W-VB Part No. SSF-1-2-VB Part No. W6-VBH Part No. W6-VBH Part No. W6-VBH Part No. W6-VBH Two Float Probe 4 Buna Two Float Probe 4 Stainless Steel Two Float Probe 2 Stainless Steel Single Float Probe (product level only) 2 Stainless Steel OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No rev1-3.doc Rev. Date:

35 Remembering to keep daily logs of your tanks? Trying to remember alarm and delivery details? Records tank data whenever you want? Keeps records of alarms and delivery data? Well, has the answer you ve been looking for! To find out more information and how to order OMNTEC PC call customer service at (631) OMNTEC PC SOFTWARE Description OMNTEC Features Part Number: - *Not available with PROTEUS Series Controllers. OMN-PC

36 OMNTEC PC SoftwareMTG-FB-R5-XXX Part No. OMN-PC Specifications subject to change without notice, verify with manufacturer. *Not available with PROTEUS Series Controllers.

37 Remote Annunciators Part Number: RA Series Description OMNTEC remote annunciators are easy to install, reliable and cost-effective. The RA series remote annunciators add audible and visible high-level alarms to OMNTEC s LPD, LU and LU-OW controllers. The primary application of OMNTEC remote annunciators is as a cautionary audio-visual alarm to signal a filling operator that a tank is approaching an overfill condition. A major benefit of OMNTEC s remote annunciators is that they need no external power source. This feature ensures cost-effective and timesaving installation. RA-Series visual annunciators are LED indicators rated MTBF 11 years. The annunciators audible alarm is a lowvoltage, 95-decibel piezoelectric alarm. The RA-NYS offers a remote annunciator option for conditions when distance or background noise requires a high-intensity, high-decibel remote annunciator. The visual indicator of the RA-NYS is a flashing strobe beacon. The audible alarm is a 110-decibel piezoelectric horn. The RA-Series has a NEMA 4X rating, which indicates a weatherproof, corrosion-resistant product. Ruggedly constructed, these remote annunciators provide reliable and cost-effective performance. Features Easily installed No external power required Tests remotely NEMA 4X weatherproof, corrosion resistant LED indicators rated MTBF 11 years High-decibel audible alarm U.L. listed Cost-effective Modified remote annunciators for special applications

38 Remote Annunciators Part No. RA Series -FB-R5-XXX Specifications Enclosure Power Input Audible Alarm RA Series Audible Alarm RA-1-NYS Red Light NEMA 4X, non-metallic, corrosion resistant max. 95 db pulsing horn 110 db pulsing horn Liquid-high-level alarm MOUNTING DIMENSIONS Response Time Immediate Operating Temperature 0 to +140 F Compatible Controllers LU series, LPD Series, and LU-OW Series Wire 22 AWG minimum RA-1 4 wire RA-2 5 wire RA-3 6 wire RA-4 7 wire RA-1-NYS 4 wire Weight 1 lb. Approvals U.L. listed 5L04 Specifications subject to change without notice, verify with manufacturer SIDE VIEW 4.02 Important: It is recommended that knockouts be placed in the bottom of the enclosure. RA-1 RA-2 RA-3 RA-4 OMNTEC REMOTE HIGH LEVEL ALARM OMNTEC REMOTE HIGH LEVEL ALARM OMNTEC REMOTE HIGH LEVEL ALARM OMNTEC REMOTE HIGH LEVEL ALARM TANK 1 TANK 1 TANK 2 TANK 1 TANK 2 TANK 3 TANK 1 TANK 2 TANK 3 TANK WHITE (+) BLACK (-) 5.03 ORANGE WHITE (+) * BLACK (-) 5.03 BLUE ORANGE WHITE (+) * BLACK (-) 5.03 BLUE BROWN * ORANGE WHITE (+) BLACK (-) RED (+) GREEN RED (+) GREEN RED (+) GREEN RED (+) GREEN RA-1-NYS 1.75 HI LEVEL OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r121208

39 LU-OW Controllers For Oil Water Separators Specifications Enclosure NEMA 4X Power Input VAC, Hz 16 watts maximum Power to Sensor Intrinsically safe for Class I, Group D hazardous locations Sensor Cable Shielded 22 AWG with drain wire Maximum length 2,000 feet Audio-Visual Controls Audible Alarm 95 db pulsing horn Red Lights High-oil-level, High-reservoir-level, and Hydrocarbon-leak Amber Lights Low-liquid-level, Low-reservoir-level, Water-leak and Caution-oil-level Green Light Power is on (system detecting) Horn-Off Button Silences horn Response Time Immediate Relay Outputs SPST normally open dry contact 1.25 amp, 120 VAC Switches when an alarm condition occurs Low-voltage Outputs 12 VDC Operating Temperature 0 to 140 F Compatible Sensors OWI-1 Single-point oil/water interface sensor (LU1-OW, LU2-OW, LU2-OWIR) OWI-2 Dual-point oil/water interface sensor (LU2-OW, LU3-OWIR) OWP-2 Dual-point pump-out sensor (LU2- OWP, LU3-OWPR) L-R-1 Reservoir sensor for double-wall fiberglass tanks (LU2-OWIR, LU3-OWIR, LU3-OWPR) PDWF Leak sensor for double-wall tanks (LU2-OWIR, LU3-OWIR) PDWS Leak sensor for double-wall tanks (LU2-OWIR, LU3-OWIR) PDS Leak sensor for double-wall tanks (LU2-OWIR, LU3-OWIR) Accessories RA-1*, RA-2*, RA-3*, RA-4*, RA-NYS *denotes number of tanks Weight LU1-OW 5 lb. LU2-OW 6 lb. LU2-OWP 6 lb. LU2-OWIR 6 lb. LU3-OWIR 6 lb. LU3-OWPR 6 lb. Approvals U.L. listed 5L04 Specifications subject to change without notice, verify with manufacturer. Part Number: Description OMNTEC s LU-OW controllers are designed to be used with oil/water separators. These audio-visual controllers monitor oil/water separators for the accumulation of oil to ensure that the oil level does not reach a dangerous volume and mix with the effluent water. The controllers are activated by float sensors, which are set by the user to match operational and site conditions. These controllers are easily tested and have an acknowledge switch on the control panel. The LU-OW product line is designed to fit a variety of sensor combinations. LU-OW controllers are highoil-level controllers. LU-OWP controllers are high-oillevel controllers with pump-out capability. LU-OWIR controllers are combination leak-sensing, high-oil-level controllers. The LU-OWPR is a combination leaksensing, high-oil-level controller with pump-out capability. The NEMA 4X rating of the LU-OW controllers indicates a weatherproof, corrosion-resistant product. The LU-OW controllers are ruggedly constructed to provide reliable and cost-effective performance. Features NEMA 4X weatherproof, corrosion-resistant Easily installed Low-voltage remote annunciator outputs Relay outputs LED indicators rated MTBF 11 years Specific sensor display Removable sensor input connectors Automatic pump-out (LU-OWP and LU-OWPR) U.L. listed Cost-effective Modified controllers for special applications LU1-OW LU2-OWIR Bottom View LU2-OW LU3-OWPR OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r doc LU1-OW LU2-OW LU2-OWIR LU3-OWPR

40 Specifications Stem and Mounting Brass (available in other materials) Float Nitrile (available in other materials) Accuracy +/ inch Cable PVC jacketed, 22AWG, 10 feet supplied OWI-1 2 conductors OWI-2 3 conductors OWP-2 3 conductors Operating Temperature -40 to 180 F Compatible Controllers OEL8000, LU1-OW, LU2-OW, LU2-OWP, LU2-OWIR, LU3-OWIR & LU3-OWPR Weight 4 lb. Approvals U.L. listed Specifications subject to change without notice, verify with manufacturer. OWI-1 OWI-2 OWS Sensors Part Number: Description Like all OMNTEC sensors, the OWS sensors are easy to install, reliable and cost-effective. The OWS sensors are designed to monitor the accumulation of oil in oil/water separators through the use of one or two floats. Primary features of these oil/water-separator sensors are their versatility and durability. They are designed in segments to allow the user to field adjust the depth at which the floats will detect oil. This enables the OWS sensors to be used with a variety of tank sizes and site parameters. OMNTEC provides even greater versatility with these sensors by offering the float, mounting and stem in a variety of materials. The OWI-1 determines the level of the oil/water interface and signals the controller to turn on the audio-visual highoil-level alarm. The OWI-2 signals both a caution level (warning an operator that the collected-oil level is nearing the pump-out level) and a high-oil level (warning the operator that the OWS has reached the required pump-out level). The OWP-2 monitors the tank for low-liquid levels and can be used for an automatic oil pump-out. Ruggedly constructed, the OWS sensors provide reliable and cost-effective performance. Features Custom lengths available Multiple floats available Rugged construction Versatile design Field adjustable Reliable Variety of float, mounting and stem materials U.L. listed Cost-effective Modified sensors for special applications OWP-2 OWI-1 OWI-2 OWP Sensor Cable (Supplied by OMNTEC) 1.5 Sensor Cable (Supplied by OMNTEC) 1.5 Sensor Cable (Supplied by OMNTEC) 2 NPT Brass Bushing (Supplied by OMNTEC) 2 NPT Brass Bushing (Supplied by OMNTEC) 2 NPT Brass Bushing (Supplied by OMNTEC) Sized to Specification Sensor Cable (Supplied by OMNTEC) Sized to Specification Sensor Cable (Supplied by OMNTEC) Sized to Specification Sensor Cable (Supplied by OMNTEC) NPT Extension Nipple (Supplied by others to extend sensor to proper depth) NPT Extension Nipple (Supplied by others to extend sensor to proper depth) NPT Extension Nipple (Supplied by others to extend sensor to proper depth) 0.5 NPT Brass Coupling (Supplied by OMNTEC) 0.5 NPT Brass Coupling (Supplied by OMNTEC) 0.5 NPT Brass Coupling (Supplied by OMNTEC) Caution Oil Level Interface Float Liquid Level Float High Oil Level Interface Float 1.86 dia. 0.5 dia High Oil Level Interface Float 1.86 dia. 0.5 dia High Oil Level Interface Float 1.86 dia. 0.5 dia. OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r121208

41 OMNTEC Mfg., Inc. Programmable 2-channel Speech Dialer Specifications Two groups of telephone numbers, 4 telephones in each group Telephone number 20 digits maximum 20 second speech message 1 16* dialing attempts 1 255* message repeats 3 second acknowledge pause between messages Exchanges operating with VDC line voltage and mA line current VDC power supply 20mA (standby) 90mA 120VDC current drain 32F to 122F operating temperature 5 7/8 x 4 1/8 x 1 3/8 in size Weighs 8.3 oz. Programmed data unaffected by power failure programmable OMNTEC

42 OMNTEC

43 Wireless Tank Monitoring Controller Part Number: OEL8000II-W Description The OEL8000II-W is a comprehensive tank overfill protection and inventory management controller that can simultaneously monitor up to 99 FillCheck level alarm sensors or Datastik inventory monitoring probes. These intrinsically safe, battery powered magnetostrictive probes provide highly accurate product level, interface (water) level, and up to five temperature measurements distributed vertically within the vessel. Multiple level alarms can be specified and annunciated for each tank being monitored. All information is displayed along with alarm conditions on the OEL8000II-W 4-line by 40-character backlit LCD display. The OEL8000II-W also accepts up to 44 of OMNTEC s Bright Eye leak detection sensors (wired). A distinct advantage of the intrinsically safe Bright Eye sensors is that they are networked and utilize 4-wire RS-485 multidrop bus interface. Other types of sensors (such as temperature and pressure) can also be connected to the buss using the patented BX Universal Translator. A built-in microprocessor gives each sensor the ability to identify itself and its location. A thermal printer is also provided which can be programmed to record alarms, tank conditions, test status, and other system-critical parameters for permanent record-keeping. With OMNTEC s proven reliability, the OEL8000II-W offers a comprehensive and user-friendly system. Features Used with DataCheck serial receiver to support wireless tank overfill protection and inventory management Supports up to 99 FillCheck, DataCheck, and DataStik wireless transmitters and DataCheck repeaters Supports up to 44 Bright Eye sensors User-configurable level alarm setpoints (Hi-Hi, Hi, Delivery Needed, Lo, Lo-Lo, etc.) and corresponding alarm annunciation Multiple user-configurable reports MODBUS RTU 4 RS RS-485 serial ports Optional FAX/modem board Optional Ethernet/TCP-IP board

44 Wireless Tank Monitoring Controller OEL8000II-W Specifications OMNTEC Receiver Cable Input Left View Front View Top View Right View Input power VAC, ± 10%, 50W Weight 20 lb. ( 9 kg) Compatible Transmitters DC-TX-D1 Agency approved for Intrinsically Safe (IS) operation (Class I, Div. 1, Groups C&D) and Non-Incendive operation (Class I, Div. 1, Groups ABCDE) Compatible Receiver DC-RX-SR-O Compatible Repeater DC-RP-12 Compatible Inventory Probes DataStik Series (required transmitter DC-TX-S2-55) Compatible High Level Sensors FillCheck Series, includes DuoCheck, MonoCheck & VersaLevel (required transmitter DC-TX-D1) Compatible Leak Sensors Bright Eye Series (BX Series) Sensors Approvals UL-listed, CUL-listed, CE-listed, CCOE Audio-Visual Alarms Display 4 line by 40 character backlit LCD Printer 36-character thermal Audible alarm 85 db piezoelectric horn Keypad 20-key oil-resistant tactile Status indicators 3 LEDs (OK, Fault, Alarm) Optional Accessories PS-102 Printer (console package part no. OEL8000IIP-W) IB-NET Ethernet TCP/IP interface board Can be configured to automatically send alarms and reports via MDR-2 14,400 baud fax/modem module Can be configured to automatically FAX alarms and reports RAS-series Various remote annunciator systems IB-RB-2 Output relay board (4 SPDT relays per board, each rated 120 5A) IB-12V Low-voltage interface board IB-C420 Analog output board (4-20 ma), only for tank 1 to tank 8 U-JBK-1 Universal junction box kit Specifications subject to change without notice, verify with manufacturer. Bottom View OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r052009

45 DataCheck Wireless Sensor Power & Control Description DataCheck is a wireless telemetry system used to power and control a variety of low-voltage intrinsically-safe (IS) sensors and transmit their data from hazardous areas. DataCheck employs state-of-the-art super high energy density lithium ion batteries and a patented sensor powering and control interface to provide longterm intermittent power and telemetry for a variety of low-power sensors. DataCheck systems consist of IS, battery operated sensors, transmitters, repeaters (if needed), and receivers. The proprietary 900 MHz frequency-hopping Spread Spectrum technology provides numerous advantages, including: Reliability: DataCheck transmitters are "fully supervised" to ensure that they are actually communicating with their assigned receivers. The battery condition of each transmitter is monitored, and "Low Battery" alarms are issued about 1 month before batteries must be replaced. Data is transmitted very redundantly over multiple channels to ensure ultra-reliable communication even in the presence of noise and RF interference. Features Battery powered for up to 5 years Intrinsically Safe (Exia) Transmitter Specifications Spread Spectrum Scheme Frequency Hopping Operating Frequency Range Operating Temperature Enclosure Rating Maximum Sensor Power Sensor Telemetry Duty Cycle Battery type Agency Approvals Overlapping Systems Multiple channels within the MHz ISM band -40 F to 150 F IP ma Programmable 10 seconds to daily or event-driven using the master discrete input 2 proprietary Lithium Thionyl Chloride D cells (16.5 Ah, 10 year shelf-life) CSA approved (US/C) Class 1 Div. Groups C&D, Exia Each DataCheck system is assigned in a unique ID code so that multiple systems can coexist within a small area. Specifications subject to change without notice, verify with manufacturer. Licensing: products are FCC approved for unlicensed operation in the 900 MHz ISM band. Superior Range: Multiple Repeaters may be employed to extend range around obstructions or over much greater distances.

46 DataCheck Wireless Sensor Power & Control Interface: The DataCheck System Architecture (DSP) provides a universal interface to all OMNTEC wireless products, including FillCheck, DataCheck, and DataStik. Each DSP can supervise up to 256 of any combination of Transmitters and Repeaters. All sensor and transmitter data plus all system alarms and diagnostic features are conveniently stored in Modbus-RTU registers which can be accesses by serial port, Ethernet (TCP/IP), or a modem. Sensor data is provided in several formats so as to be readily accessed by all popular HMI, Terminal Management Systems and tank gauging applications. OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r121908

47 Flexible Top Mounted Wireless DataStik Probe for Tank Inventory Monitoring Part Number: DS-1K-XXX-V Description The DataStik probe takes field proven magnetostrictive technology and packages it in a revolutionary new way for greater reliability, easy installation, and mounting. The DS-1K-XXX-V (where XXX is the overall probe length in inches) is ideal for liquid level monitoring of product and interface level in a wide variety of liquid media in both above ground and below ground storage tanks, and is assembled to your specifications in measuring lengths up to 70 ft. All probe electronics are integrated into a inch OD PVDF sensing tube. This breakthrough in package design eliminates the bulky electronics enclosure at the top of the probe and offers you greater options for insertion and mounting in tanks and vessels. The DS-1K-XXX-V employs a flexible PVDF housing and provides cost-effective inventory monitoring for a wide variety of vessels and liquids. The DS-1K-XXX-V s lower cost design provides more options, offers savings on installation and mounting and has the ultimate in designed-in reliability. The DS-1K-XXX-V includes the patented DataCheck Transmitter, batteries, and mounting mast. Features Patented wireless, battery-powered technology Rugged, Reliable Magnetostrictive Design with Electronics Integrated into 5/8 Sensing Tube High Resolution and Accuracy CSA approved Intrinsically Safe (Exia) Flexible PVDF Numerous Float Options for nearly any application No Calibration Required

48 Flexible Top Mounted Wireless DataStik Probe Part No. DS-1K-XXX-V Specifications Power Two D-cell lithium thionyl chloride batteries (1 for DataStik Probe, 1 for DataCheck Transmitter) Measurement Length Up to 70 ft. Resolution 0.01 mm Accuracy ± 0.1 mm Linearity ± 0.01% of full scale ± 0.010,whichever is greater Repeatability Equal to resolution Temperature Measurement Up to five along the probe span Temperature accuracy, Absolute -10 C to +85 C ± 0.5 C -40 C to -11 C ± 2.0 C Temperature Sensing Range -40ºF to +65ºC Operating Temperature Range -40ºF to + 71ºC Compatible Controller OEL8000II-W Probe Output to Transmitter Serial data Distance to Receiver Up to 1 km, unlimited using DataCheck Repeaters System Configuration see DataStik Product Bulletin Wireless Scheme Full Supervised Simplex MHz FHSS Electrical Safety Approval CSA US/C Exia intrinsically safe Specifications subject to change without notice, verify with manufacturer. These products are protected under US Patents 6,229,448 and 6,369,715. Other patents pending. 3/4 MNPT 3/4 MNPT *Final Probe Tank Fitting 3/4 FNPT Float Stop Product Float Float Options Weight / Spacer 4 Buna Float Part No. BNF-4 BNF-1-4 (product float only) 2 Stainless Steel Part No. SSF-2 SSF-1-2 (product float only) 4 Stainless Steel Float Part No. SSF-4 SSF-1-2 (product float only) Note: For dual float probes with overall length greater than 288, a float spacer will be required between two floats. W2 Series Weight Overall Length Weight Part No. Weight Dimensions Dimensions (2 diameter) Weight or Spacer W (h) Spacer W (h) Weight W (h) Weight W (h) Weight W (h) Weight W (h) Weight W2 Series Weight OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No rev1-0.doc Rev. Date:

49 Flexible Fixed Bottom Wireless DataStik Probe For Tank Inventory Monitoring Part Number: DS-2K-XXX-VB COMPENSATE FOR ROOF MOVEMENT UNPARALLELED INVENTORY ACCURACY ACCURATE TEMPERATURE COMPENSATION MEASURE AS LOW AS 1 OF WATER OFF TANK BOTTOM ALL FROM ONE TANK OPENING ALL WITHOUT TAKING YOUR TANK OUT OF SERVICE! Description DS-2K-XXX-VB (where XXX is the overall probe length in inches, from 211 to 862 ) is a flexible PVDF magnetostrictive tank inventory management probe which enables very accurate product level and measurement of as little as 1 (25mm) of water in the bottom of tanks. It also provides five temperature measurements spaced evenly 1 meter from the tank floor. The DS-2K-XXX-VB benefits from a bottom reference approach by resting a heavy hollow weight on the bottom of each tank. This unique OMNTEC bottom reference design takes full advantage of the tank bottom stability versus known instabilities of a tank roof. The tank bottom reference design is further enhanced by a top mounted constant tension feature. This feature maximizes the probe s level accuracy to less than 0.01 of an inch by removing tank movements and its influence on measurement. In turn this OMNTEC exclusive design maximizes the operator s ability to manage inventory with accuracy and confidence. The DS-2K-XXX-VB is typically installed on a 6 or larger process fitting. Other fitting may be accommodated. Please consult the factory for a detailed review of your unique application. Numerous product float options are available, dependent on the density and composition of the tank product. As with all DataStik Probes, the DS-2K-XXX-VB includes the patented DataCheck sensor power and telemetry system. The included DataStik Transmitter provides lithium battery powering and telemetry. Battery will last for up to five years, depending on user selectable duty cycle. The Transmitter is factory programmed to provide duty cycles from 10 seconds to 30 minutes. A dynamic duty cycle can be configured to increase transmission rate upon indication of an abnormal movement, increased flow rates and/or reaching a predetermined level. The Transmitter performs battery diagnostics every 18 hours and will emit a Low Battery Alarm approximately 30 days prior to battery exhaustion. The DataCheck Receiver, which can monitor up to 99 Transmitters, can be programmed to emit Inactive Transmitter Alarms if any Transmitter fails.

50 Flexible Fixed Bottom Wireless DataStik Probe Part No. DS-2K-XXX-VB Spring Rod Cap Cover Tube Specifications Part No. DS-2K-XXX-VB Input Voltage +5 VDC, +/- 10 % typical (+3.7VDC Min.) Overall Probe Length 211 to 862 Enclosure Rating PVDF, IP 68 Typical Level Resolution Linearity 0.01% Repeatability Equal to resolution Temperature Up to 5 along the sensor span Measurement Temperature Accuracy, -10 C to +85 C +/- 0.5 C Absolute -40 C to -11 C +/- 2.0 C Typical Temperature 0.1 C Resolution Temperature Sensing -40 F to +158 F or Range -40 C to 70 C Operating Temperature -40 F to +158 F or Range -40 C to 70 C Probe Output Simplex serial Distance to Monitor Up to 1 km, wireless (further with repeaters) Compatible Controller OEL8000II-W Floats BNF Buna Product Float SSF Stainless Steel Product Float SSF Stainless Steel Product Float SSF-1-2W-VB 2 Stainless Steel Water Float for low water detection applications (used with W6-VBH weight) SSF-1-2-VB 2 Stainless Steel Product Float for low product detection applications (used with W6-VBH weight) Specs based on 4 buna Weight W6-VBH 5.75 (dia) x 7 (h) Stainless Steel Weight for use in low water or product applications when used in conjunction with floats SSF-1-2W-VB and SSF-1-2-VB. Requires a 6 accessible opening on tank top. Spacer SFS Stainless Steel Float Spacer required on probe lengths 288 or greater Listings CSA, Intrinsically safe when used in accordance with OMNTEC drawing Specifications subject to change without notice, verify with manufacturer. Cable 2 Cond. 22 AWG Belden or Equiv. 7.5 long Support Rods Tank Coupling ½ NPT (for conduit) *Final Probe Tank Fitting 2 FNPT dia. Flexible PVDF shaft Product Float (BNF-1-4 shown) Spacer (SFS shown) Interface Float (SSF-1-2W-VB shown) Weight (W6-VBH shown) Rests on tank floor Float and Weight Options Part No. BNF-1-4 Part No. SFS Part No. SSF-1-4 Part No. SFS Part No. SSF-1-2 Part No. SFS Part No. SSF-1-2W-VB Part No. SSF-1-2W-VB Part No. SSF-1-2W-VB Part No. SSF-1-2-VB Part No. W6-VBH Part No. W6-VBH Part No. W6-VBH Part No. W6-VBH Two Float Probe 4 Buna Two Float Probe 4 Stainless Steel Two Float Probe 2 Stainless Steel Single Float Probe (product level only) 2 Stainless Steel OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No.: rev1-1.doc Rev. Date:

51 Rigid Stainless Steel Wireless DataStik Probe for Tank Inventory Monitoring Part Number: DS-NS-XXX Description The DataStik probe takes field-proven magnetostrictive technology and packages it in a revolutionary new way for greater reliability, easy installation, and mounting. The DS-NS-XXX (where N is the number of floats [1 or 2], and XXX is the overall probe length in inches) is ideal for liquid level monitoring of product and interface level in a wide variety of liquid media in both above ground and below ground storage tanks, and is assembled to your specifications in measuring lengths up to 50 ft. All probe electronics are integrated into a inch OD 316-Stainless Steel sensing tube. This breakthrough in package design eliminates the bulky electronics enclosure at the top of the probe and offers you greater options for insertion and mounting in tanks and vessels. The DS-NS-XXX employs a rigid stainless steel housing and provides cost-effective inventory monitoring for a wide variety of vessels and liquids. The DS-NS-XXX V s lower cost design provides more options, offers savings on installation and mounting and has the ultimate in designed-in reliability. The DS-NS-XXX includes the patented DataCheck Transmitter, batteries, and mounting mast. Features Patented wireless, battery-powered technology Rugged, Reliable Magnetostrictive Design with Electronics Integrated into 5/8 Sensing Tube High Resolution and Accuracy CSA approved Intrinsically Safe (Exia) Strong, rigid 316-SS housing Numerous Float Options for nearly any application No Calibration Required

52 Rigid Stainless Steel Wireless DataStik Probe Part No. DS-NS-XXX Specifications Power Two D-cell lithium thionyl chloride batteries (1 for DataStik Probe, 1 for DataCheck Transmitter) Measurement Length Up to 24 ft. (7.3M) Resolution 0.01 mm Accuracy ± 0.1 mm Linearity ± 0.01% of full scale ± 0.010,whichever is greater Repeatability Equal to resolution Temperature Measurement Up to five along the probe span Temperature accuracy, Absolute -10 C to +85 C ± 0.5 C -40 C to -11 C ± 2.0 C Temperature Sensing Range -40ºF to +65ºC Operating Temperature Range -40ºF to + 71ºC Compatible Controller OEL8000II-W Probe Output to Transmitter Serial data Distance to Receiver Up to 1 km, unlimited using DataCheck Repeaters System Configuration see DataStik Product Bulletin Wireless Scheme Full Supervised Simplex MHz FHSS Electrical Safety Approval CSA US/C Exia intrinsically safe Specifications subject to change without notice, verify with manufacturer. These products are protected under US Patents 6,229,448 and 6,369,715. Other patents pending. Swage Lock 3/4 MNPT *Final Probe Tank Fitting 3/4 FNPT Float Options Product Float Cathodic Boot 4 Buna Float Part No. BNF-4 BNF-1-4 (product float only) 2 Stainless Steel Part No. SSF-2 SSF-1-2 (product float only) 4 Stainless Steel Float Part No. SSF-4 SSF-1-2 (product float only) OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r031009

53 Background In the wake of the Buncefield disaster in the UK (December 2005), the various regulatory entities and standards organizations have been scrambling to upgrade recommended practices and procedures to minimize the risk for storage tank overfill and hopefully prevent a recurrence of this tragedy. The API 2350 subcommittee is working on the final draft for the 4th edition of Overfill Protection for Storage Tanks in Petroleum Facilities which will be released in the summer of This new edition will probably be used as the basis for an ANSI standard, which will make it the de facto standard for most of the world. It is anticipated that the new standard will require that all petroleum storage facilities be categorized based upon the type of product stored, and the way the tanks are filled. A Category 4 (worse case) facility would store gasoline, and delivery would be at very high flow rates from a pipeline. No matter what Category a facility falls under, one of the main lessons learned from Buncefield is that an overfill protection system must be tested routinely. The entire system, from the level sensors to the alarms, must have a testing methodology which is representative of an actual alarm condition. As the industry s premier tank monitoring experts, OMNTEC is committed to keeping our clients current with the latest requirements, and to providing best-in-class solutions for all their tank monitoring requirements. Level Sensors For Overfill AST Protection 1 MNPT Part Number: MagLift 2 MNPT *Floats 2.05 (dia) x (h) DuoCheck Sensor For fixed roof tanks (available in various lengths) Compatible Contoller: OEL8000II-W Required Accessories: DC-TX-D1 MagLift FI-NM-DC-M (DuoCheck ) FI-NM-V2-M (Versalevel -02) FP (Versalevel -X2) NOTE: Single point sensors and numerous other types of level sensors are also available. Please consult factory for details. Solution One of the most important requirements for successful tank overfill protection is the selection of the proper sensor for the application. This is usually a function of the tank type, and the stored product. There are 3 basic types of aboveground storage tanks; namely, a) fixed roof, b) internal floating roof, and c) external floating roof. Of course, there are many other types of vessels, and application specific requirements such as heating and refrigeration which must be considered when selecting the proper sensors for overfill protection. OMNTEC has developed state-of-the-art level sensors for these 3 basic tank types. For all of these, we offer both single and dual point (HI + HI-HI) variants although we almost always recommend a dual point system. For fixed roof tanks (FRT s), the DuoCheck sensor is normally used. DuoCheck is a coaxial dual float switch which employs the MagLift pull-to-test mechanism. Many commercial level sensors feature a pull-to-test feature; however, many of these can provide misleading test results as the testing mechanism may transfer much more force to the sensor than its buoyancy can induce. 1 FNPT 2 MNPT *Floats (dia) x 2.7 (h) Versalevel -02 Sensor For internal floating roof tanks (available in various lengths) Compatible Contoller: OEL8000II-W Required Accessories: DC-TX-D1 *IMPORTANT: Be sure tank opening is greater than float diameter.

54 MagLift Operating Principle This may lead to temporarily freeing fouled sensors thus leading the operator to assume proper operation when in fact the sensor actually requires cleaning and maintenance. The MagLift mechanism is a magnetically coupled testing mechanism which can only transfer sufficient force to the sensor to successfully test it if it is not fouled. The diagram on the right shows the testing sequence for level sensors equipped with MagLift. For internal floating roof (IFR) tanks the Versalevel -02 sensor is normally recommended. This is a dual displacer switch where the internal floating roof normally lifts the displacers sequentially (hi then hi-hi) to generate the alarms. As with the DuoCheck sensor, the Versalevel is tested using the MagLift mechanism. Should the internal floating roof be sunk, or if product is on top of the roof, the displacers are sufficiently buoyant to activate the mechanism. For external floating roof (EFR) tanks the Versalevel -X sensor is normally recommended. In EFR tanks, wind, ice and snow prevent the use on displacer-type sensors; hence, the Versalevel -X employs a heavy float on a rod containing an internal tilt switch. The float/rod assembly is suspended from the tank shell, and must be tilted to a 45 angle to activate the alarm. As with the standard Versalevel sensor, the float on the Versalevel -X is sufficiently buoyant so as to detect liquid if the roof has sunk or if water has accumulated on the roof. The Versalevel -X is also useful for fixed roof tanks containing viscous, dirty, or sticky products. The Versalevel -X is equipped with a pull-to-test lanyard which is attached to the bottom of the float/rod which tips the sensor up to an angle sufficient to activate the tilt switch. Versalevel -X For external floating roof tanks Compatible Contoller: OEL8000II-W Required Accessories: DC-TX-D1 Specifications subject to change without notice, verify with manufacturer. OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r1344.doc

55 GOALS: Minimizetankcontamination Minimizetransmixvolumes Providesinstantaneousandhighly sensitiveinterfacedetectioninshared productpipelines ProbeisCOMPLETELYfiberopticandthus inherentlysafe Nooutdoorelectronics:systemimmune tolightningandemp 3 rd partyautomatedbatchcontrol softwareavailablefromesi Probecanbelocatedupto2kmaway fromcontrollerusing offtheshelf industrialfiberopticcable Senseschangesinrefractiveindex(rather thandensity)todifferentiateadjacent pipelineproductbatches Refractiveindexmeasurementis extremelysensitivetosmalldifferencesin fluidcomposition;thus,muchmore precisebatchcutsarepossiblethanwith density Whenproperlyappliedusingtandem sensors,vastreductionsintransmix volumesaretypical Probemaybeinstalledflushwithpipeline I.D.sopiggingcanbeaccomplished withoutretractingprobe FuelCheck Pipeline Batch Control FuelCheck Controller Fiberoptic JunctionBox (nonhazardousarea) FiberopticCable upto2km * Part Number: analog output toscada 24VDC@2A FuelCheckProbe (thruvalveinstallation) PIPELINE FU-CT-XI* FU-PR-24 1,2,and3probemodelsavailable Analogoutputstandard(420mA,010 VDC,etc.):serialandEthernet(TCP/IP) protocolsoptionallyavailable *Suppliedbyothers LocalLEDdisplaysindicateopticalgainand finalanalogoutput

56 FuelCheck Pipeline Batch Control SPECIFICATIONS FuelCheckProbe Description: opticalprocessrefractometer Sensor: 5mmsapphirehemisphere SensorMode: intensitybased U.S.PatentNo.: 5,946,048 ElectricalSafetyClass: inherentlysafe,nonelectrical ProbeConstruction: 0.5 O.D.316stainlesssteel PartNumber: FUPR24 OperatingPressure: 10MPa(1,450psi)maximum Max.InstallationPressure: 2MPa(300psi),standardinsertiontool 10MPa(1,500psi),optionalinsertiontool ProcessTemperature: 80 C(176 F)maximum ProcessFitting: 1inchANSIClass600RFflange Req.ProcessConnection: 1inchballvalve(suppliedbyothers) FiberopticInterconnect FiberType: 200/230μmHCSmultimode,duplex ConnectorType: STcrimp&cleave Manufacturer: OFS Max.Length: 2km(ProbetoController) FuelCheckController Description: thermallystabilizedfiberopticpowermeter PartNumber: FUCTxI(wherexis1,2,or3channels) Enclosures: NEMA4Xnonmetallic ElectricalSafetyClass: nonhazardousareasonly PowerRequirement: Emitter: ultrahighintensity850nm(nir)led SensitivityThreshold: 55dBm DynamicRange: >50dB DetectorOutput: VDCintoscalablesignalconditioner Accessories FUPRHP highpressureprobeinsertiontoolforfupr24 FUC2DB fiberopticinterconnect2fiberdirectburial cablearmored FUFOCN fiberopticconnectors FuelCheckResponse

57 OMNTEC The Basics OMNTEC Mfg., Inc. has been in business since 1987 providing the Petroleum and Industrial markets with both wired and wireless solutions to their leak detection, tank gauging, & high level alarm needs. We offer standard leak detection equipment, both product distinguishing and non distinguishing, tank gauging using both rigid and flexible magnetostrictive gauging probes for low clearance and chemical applications, as well as simple set point level monitoring and pump controls. We have developed this quick reference sheet to act as a checklist for typical applications when ordering or quoting OMNTEC equipment. Please do not hesitate to call on us if further assistance is needed. Wireless Level Gauging CONTROLLER OEL8000II-W mounted indoors RECEIVER DC-RX-SR-O mounted outdoors LEVEL GAUGING DS-2K-240V with transmitter REPEATER DC-RP-12 may not be necessary in all applications Wireless Level Gauging OEL8000IIP-W Tank Gauging controller with 4-line by 40 character display and printer, connects to DataCheck serial receiver with volumetric tank data and alarm capability, capable of monitoring up to 99 devices *DS-2K-240V DataStik Series 7255V PVDF, 20' overall tank height, all flexible PVDF, w/ SS product and water float, & SS weight DC-RX-SR-O Serial Receiver, outdoor in NEMA-4X enclosure, 5' fiberglass mounting mast & serial cable included DC-RP-12 Repeater with 12 hr. back-up battery, NEMA-4X non-metallic enclosure, 5' fiberglass mounting mast (optional when required) *Part number & pricing based on a 20 foot tall tank. Available up to 70 feet. OMNTEC

58 OMNTEC The Basics OMNTEC Mfg., Inc. has been in business since 1987 providing the Petroleum and Industrial markets with both wired and wireless solutions to their leak detection, tank gauging, & high level alarm needs. We offer standard leak detection equipment, both product distinguishing and non distinguishing, tank gauging using both rigid and flexible magnetostrictive gauging probes for low clearance and chemical applications, as well as simple set point level monitoring and pump controls. We have developed this quick reference sheet to act as a checklist for typical applications when ordering or quoting OMNTEC equipment. Please do not hesitate to call on us if further assistance is needed. Wireless Level Gauging with Redundant Overfill Protection TRANSMITTER DC-TX-D1 LEVEL GAUGING DS-2K-240V with transmitter CONTROLLER OEL8000II-W mounted indoors RECEIVER DC-RX-SR-O mounted outdoors HIGH LEVEL FI-NM-DC-D HIGH HIGH HIGH REPEATER DC-RP-12 may not be necessary in all applications Wireless Level Gauging with Redundant Overfill Protection OEL8000IIP-W Tank Gauging controller with 4-line by 40 character display and printer, connects to DataCheck serial receiver with volumetric tank data and alarm capability, capable of monitoring up to 99 devices *DS-2K-240V DataStik Series 7255V PVDF, 20' overall tank height, all flexible PVDF, w/ SS product and water float, & SS weight FI-NM-DC-D DuoCheck dual level (hi & hi hi) 2" float switch w/maglift checking mechanism, 6' long, all SS, Delrin j-box, w/ mounting bracket DC-TX-D1 FillCheck transmitter DC-RX-SR-O Serial Receiver, outdoor in NEMA-4X enclosure, 5' fiberglass mounting mast & serial cable included DC-RP-12 Repeater with 12 hr. back-up battery, NEMA-4X non-metallic enclosure, 5' fiberglass mounting mast (optional when required) *Part number & pricing based on a 20 foot tall tank. Available up to 70 feet. OMNTEC

59 Custom Control Panels Part Number: CEL Series Description Pump controls available for duplex, alternating and lead lag pumps. Panels may include relay contacts for pump control and remote annunciation, disconnect switches, pump failure and running indicators, tank selector switches, HOA (hand off auto) switches, motor starters, local alarm horn and lights. All panels are built with U.L. recognized components. Enclosures available in NEMA 4, 4X, 7, and 12. Controllers based on PLC (Programmable Logic Controller) Technology. Pump In/Pump Out Control Alternating Pump Control Lead Lag Pump Control Duplex Pump Control Tank Drain Control Tank Fill Control Valve Control OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) Website: Document No r120808

60

61 PUMP CONTROLLER Part Number: PC-1T2LHOA System Overview The PC-1T2LHOA pump control panel is designed to monitor one tank in conjunction with a two point float switch for High level, and Low level to control an existing remotely powered pump motor starter. Automatic Mode When power is applied to the system while mode switch is in Auto position, the tank will be pumped down until the low level float switch is actuated. This condition will send a dry contact signal to motor starter to turn pump on as well as illuminate the pump on light. The pump will continue to pump into the tank until the high level float switch is actuated. This condition will cause the pump on light to turn off and unlatch the dry contact signal to the motor starter causing the pump to turn off. Manual Mode When the mode switch is in Hand, the tank will be pumped down until the low level float switch is actuated. This condition will illuminate the pump on light only to indicate there is a low level condition. The pumps must be turned on manually to begin pumping into the tank. Upon the level reaching the high level float switch, the pump on light will turn off indicating that a high level condition has occurred. The pump must then not be manually turned off. This mode is generally used when maintenance is being preformed on the pump or the pump controller/pump has failed. Off Mode When the mode switch is in the Off position, the system will be shutdown thus NOT providing any alarms and pumps must be manually controlled. Specifications Features System is designed to interface with motor started (provided by others) 120VAC Power Input Weight and Dimensions 7lbs. (W) 8 x (H) 10 x (D) 5 Sensor Cable Shielded 22 AWG UL-E CM Maximum length 2000 feet Enclosure Operating Temperature Visual Console Sensors Typical Applications NEMA 4X -40º to 140º F Green light - Indicates pump running 3 Position Selector Switch - Hand - Off - Auto LF-2 Two point float switch (N.C. in down position) Fire Suppression, potable water, irrigation, generator and day tanks Notes: (1) This system is designed to monitor one tank in conjunction with two point float switch for High level and Low level to control an existing remotely powered pump motor starter. (2) Panel can be modified for pump out applications (such as waste oil pump out). Part number: PC-1T2LHOA-PO Specifications subject to change without notice, verify with manufacturer. OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r121208

62 Valve Controller Part Number: VC-1T2LHOA System Overview This system is designed to monitor one tank in conjunction with a two point float switch for High Level and Low Level to control an existing 120VAC solenoid valve. Automatic Mode When power is applied to the system while mode switch is in Auto position, the valve will open at the low level switch. This condition will energize the 120VAC solenoid valve and illuminate the valve open light. The valve will remain open until the high level float switch is actuated. This condition will cause the valve open light to turn off and de-energize the valve causing the valve to close. Manual Mode When the mode switch is in Hand valve will open until the low level float switch is actuated. This condition will illuminate the valve open light only to indicate there is a low level condition. Upon the level reaching the high level float switch, the valve open light will turn off indicating that a high level condition has occurred. This mode is generally used when maintenance is being preformed on the valve or the valve controller has failed. Off Mode When the mode switch is in the Off position, the system will be shutdown thus NOT providing any alarms and valve must be manually controlled. This mode is generally used when maintenance is being preformed on the VC-1T2LHOA or valve, or the valve controller has failed. Specifications Features System is designed to interface with 120VAC solenoid valve (provided by others) Power Input 120VAC Weight and Dimensions 7lbs. (W) 8 x (H) 10 x (D) 5 Sensor Cable Shielded 22 AWG UL-E CM Maximum length 2000 feet Enclosure NEMA 4X Operating Temperature -40º to 140º F Visual Console Green light - Indicates valve open 3 Position selector switch - Open - Close - Auto 3 position selector switch - Open - Close - Auto 3 Position Selector Switch - Hand - Off - Auto Sensors LF-2 Two point float switch (N.C. in down position) Typical Applications Fire Suppression, potable water, irrigation, generator and day tanks Notes: (1) This system is designed to interface with a 120VAC solenoid valve (provided by others). If valve is not 120 VAC solenoid, please contact factory for alternatives. (2) Panel can be modified for pump out applications (such as waste oil pump out). Part number: VC-1T2LHOA-PO Specifications subject to change without notice, verify with manufacturer. OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No r121208

63 LF Series Liquid Float Sensor Part Number: LF Series Liquid Level Float Sensors Stainless Steel or Brass Mountings 1 to 6 Actuation Levels Lengths to over 11 feet U.L. Recognized, CSA Listed LF series float sensors have multiple options including material of construction, mountings and float sizes. This allows for the LF sensor to be extremely versatile in a wide range of applications such as water, oils, chemicals and corrosive liquid. LF-* switches are U.L. Approved for Class I, Division 2, Groups A, B, C, D hazardous locations. FM Approved explosion proof junction box must be installed for Class I, Division I, Group D hazardous locations. Specifications BUNA N Stainless Steel Operating Temperature Water: to 180 F Oil: -40 F to +230 F 40 F to +300 F Stem & Mounting Material Brass 316 Stainless Steel Max Length (Lo) 120" (305 cm) Float Stops* Beryllium Copper 316 Stainless Steel Compatible Controllers Consult factory Approvals U.L. Recognized, CSA Listed Specifications subject to change without notice, verify with manufacturer. Group 1 Switch (N.O. or N.C.): SPST: 50 VA Group 2 Switch (N.O. or N.C.): SPST: 50 VA For clarity, only two actuation levels are shown in each group diagram. Standard setup is Group 2 unless otherwise specified. BUNA N Float Stainless Steel Float Consult factory for materials other than stainless steel and BUNA N.

64 Liquid Float Sensor Part No. LF Series Switch actuation levels are determined following the guidelines below: All units 72" or less overall unit length with Stainless Steel or Buna N floats. A = 1-1/2" (38.1mm) minimum distance to highest level (2" (50.8mm), Type 5 only) B = 2" (50.8mm) minimum distance from end of unit to lowest level C = 3" (76.2mm) minimum distance between levels D = 1/4" (6.3mm) minimum distance between actuation levels (Note: One float for two levels can be used only when low level is N.C. dry and high level is N.O. dry) * Actuation level distances and L0 (overall unit length) are measured from inner surfaces of mounting plug or flange ** Length Overall L0 = L1 + Dimension B. See mounting Types for Maximum Length values Notes: 1. A, B and C dimensions based on a liquid specific gravity of One float for two levels can be used only when 20VA switch is used 3. Actuation levels are calibrated on descending fluid level, with water as the calibrating fluid, unless otherwise specified 4. Tolerance on actuation levels is +/- 1/8" (3.2mm) Optional Alternative Mounting for ½ NPT Wiring Color Code Wiring Level 1 Level 2 Level 3 Level 4 Level 5 LF-1 black/red LF-2 black/red green/white LF-3 white/red blue/green black /orange LF-4 black/red green/white blue/orange yellow/brown LF-5 black/red green/white blue/orange yellow/brown purple/grey Type 1 ½ (12.7mm) NPT Type 2 1-¼ (31.8mm) NPT Type 3 2 (50.8mm) NPT Type 4 3 (76.2mm), 150# Dia. Flange Stem and Mounting Material Brass or 316 Stainless Steel Flange: Carbon Steel or 316 S.S. Stem: 316 S.S. Max Length 36 (91.4 cm) 60 (152.4 cm) 140 (355.6 cm) Mounting Position Vertical 30 Inclination Float Stops* Brass Units: Beryllium Copper Grip Rings, Stainless Steel Units: S.S. ARMCO PH-15-7MO Grip Rings * Units greater than 72" (1828mm) overall length are supplied with collars with setscrews (made of same material as stem and mounting) in place of float-stop rings. Collars are optional on units less than 72" (1828mm) overall length. Units requiring 316 SS float stops must be special ordered with 316 SS collars instead of grip rings. In some instances the use of concentration of chlorine and other corrosive compounds in the media require the use of collar type float stops. Consult factory for details. OMNTEC Mfg., Inc Pond Road Ronkonkoma, NY Phone: (631) Fax: (631) omntec@omntec.com Website: Document No rev1-0.doc Date:

ELP21LU3-LF-HLOL THREE CHANNEL

ELP21LU3-LF-HLOL THREE CHANNEL ELP21LU3-LF-HLOL THREE CHANNEL 516-467-5787 HI LEVEL LOW LEVEL LEAK DETECTION 11.00 TEST SYSTEM DETECTING HORN OFF 6.00 SPECIFICATIONS POWER INPUT 85-125 VAC, 47-440 Hz 16 Watts maximum POWER TO SENSORS

More information

PROTEUS Series OEL8000III-K. Tank Gauging System. Installation Manual

PROTEUS Series OEL8000III-K. Tank Gauging System. Installation Manual OMNTEC PROTEUS Series OEL8000III-K Tank Gauging System Installation Manual Page 1 of 23 PROPRIETARY INFORMATION NOTICE This document contains information and material developed by OMNTEC Mfg., Inc. All

More information

Established in Serving the Petroleum and Industrial markets with both wired and wireless solutions.

Established in Serving the Petroleum and Industrial markets with both wired and wireless solutions. Established in 1981 Serving the Petroleum and Industrial markets with both wired and wireless solutions. OMNTEC Compliance & Leak Detection Systems to Meet the Needs of our Customers UL508 controls Wireless

More information

1993 Pond Rd., Ronkonkoma, NY Tank Gauging Liquid Level and Leak Detection Systems Relays. OEL8000II Installation Manual PRINT MENU DEL 1 ABC

1993 Pond Rd., Ronkonkoma, NY Tank Gauging Liquid Level and Leak Detection Systems Relays. OEL8000II Installation Manual PRINT MENU DEL 1 ABC OMNTEC Mfg., Inc. 1993 Pond Rd., Ronkonkoma, NY 11779 Tank Gauging Liquid Level and Leak Detection Systems Relays OEL8000II Installation Manual OMNTEC OEL800OII TANK MONITORING SYSTEM OK FAULT ALARM PRINT

More information

THREE CHANNEL CONTROLLER OMNTEC

THREE CHANNEL CONTROLLER OMNTEC MNTEC Mfg., Inc. 1993 Pond Rd., Ronkonkoma, NY 11779 Tank Gauging Liquid Level and Detection Systems Relays LU3 THREE CHANNEL CNTRLLER MNTEC 631-467-5787 L1 L2 L3 TEST SYSTEM DETECTING HRN FF Phone 631-981-2001

More information

NINE CHANNEL CONTROLLER OMNTEC

NINE CHANNEL CONTROLLER OMNTEC MNTEC Mfg., Inc. 1993 Pond Rd., Ronkonkoma, NY 11779 Tank Gauging Liquid Level and Detection Systems Relays LU9 NINE CHANNEL CNTRLLER MNTEC 631-467-5787 L1 L4 L2 L5 L3 SYSTEM DETECTING L7 L6 L8 TEST L9

More information

SINGLE CHANNEL CONTROLLER

SINGLE CHANNEL CONTROLLER MNTEC Mfg., Inc. 1993 Pond Rd., Ronkonkoma, NY 11779 Tank Gauging Liquid Level and Detection Systems Relays LU1 SINGLE CHANNEL CNTRLLER MNTEC 631-467-5787 L1 TEST SYSTEM DETECTING HRN FF Phone (631) 981-2001

More information

SiteSentinel itouch Console

SiteSentinel itouch Console SITESENTINEL ITOUCH CONSOLE SiteSentinel itouch Console OPW s SiteSentinel itouch is a multifunction, high-quality tank-monitoring system that provides real-time, accurate inventory information for up

More information

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER PNEUMERCATOR Liquid Level Control Systems Electronic Systems Excluding LC2000 And TMS Series MAINTENANCE & TROUBLESHOOTING GUIDE 400 300 500 FUEL LEVEL LEAK MONITOR 1 200 600 OIL/GAS NORMAL WATER PNEUMERCATOR

More information

INSTRUCTION MANUAL MODEL LDE 740. (Revised July 8, 2017)

INSTRUCTION MANUAL MODEL LDE 740. (Revised July 8, 2017) PNEUMERCATOR Liquid Level Control Systems Multi Tank Monitoring System INSTRUCTION MANUAL MODEL LDE 740 (Revised July 8, 2017) COPYRIGHT 2017 PNEUMERCATOR CO. 1785 EXPRESSWAY DRIVE NORTH, HAUPPAUGE, NY

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor... Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable

More information

BID-SPEC_INTEGRA_100 Rev. 0. Bid Specifications and General Description OPW SiteSentinel Integra 100 Automatic Tank Monitoring System

BID-SPEC_INTEGRA_100 Rev. 0. Bid Specifications and General Description OPW SiteSentinel Integra 100 Automatic Tank Monitoring System BID-SPEC_INTEGRA_100 Rev. 0 Bid Specifications and General Description OPW SiteSentinel Integra 100 Automatic Tank Monitoring System Part 1. General Overview 1.1 Summary This document describes the minimum

More information

Colibri. Automatic Tank Gauge CL6 Series Installation Guide

Colibri. Automatic Tank Gauge CL6 Series Installation Guide Colibri Automatic Tank Gauge CL6 Series Installation Guide Manual # Revision Date Changes from Previous Revision 000-2153 C Jan. 2013 Pipe compound brand change, Updated Control drawing. Franklin Fueling

More information

Manual No: Revision: G. Sensor Products. Application Guide

Manual No: Revision: G. Sensor Products. Application Guide Manual No: 577013-750 Revision: G Sensor Products Application Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties

More information

Electronic Fuel Management Systems

Electronic Fuel Management Systems Electronic Fuel Management Systems Making Sure You re in Complete Control, From Anywhere, All The Time. Innovation is a defining value principle at OPW Fuel Management Systems (FMS). OPW FMS provides the

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Model A1700 Series Annunciator

Model A1700 Series Annunciator Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage. LC-100 Tank Level Indicator Engineered specifically for the Offshore & Marine markets, LevelCom TLI s have a proven record of success in 20 years of use in harsh environments. The LC-100 microprocessor

More information

TLS-350R UST Monitoring and Leak Detection System With Automatic Business Reconciliation

TLS-350R UST Monitoring and Leak Detection System With Automatic Business Reconciliation Part 1 General System Requirements 1.1 Description TLS-350R UST Monitoring and Leak Detection System With Automatic Business Reconciliation A. These Specifications are intended to provide information by

More information

INSTRUCTION MANUAL. Revised: July 2, 2017 DRAWING NO REV. A LC1000 SERIES INTRINSICALLY SAFE ALARM CONSOLE

INSTRUCTION MANUAL. Revised: July 2, 2017 DRAWING NO REV. A LC1000 SERIES INTRINSICALLY SAFE ALARM CONSOLE PNEUMERCATOR Liquid Level Control Systems AUDIBLE ALARM CONTROLS INSTRUCTION MANUAL Revised: July 2, 2017 DRAWING NO. 20000 REV. A LC1000 SERIES INTRINSICALLY SAFE ALARM CONSOLE COPYRIGHT 2017 PNEUMERCATOR

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors. Fire Sentry Corporation (FSC) 593 Apollo Street Tel.: 714-671-1100 Brea, California 92821 Fax: 714-671-5821 Multi-Spectral, Digital, Infrared Electro-Optical FSC Model No. s FS10-R and FS10-A Unitized,

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

TLS-300 UST Monitoring and Leak Detection System

TLS-300 UST Monitoring and Leak Detection System Part 1 General System Requirements 1.1 Description TLS-300 UST Monitoring and Leak Detection System A. These Specifications are intended to provide information by which prospective bidders may understand

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification

More information

Section PERIMETER SECURITY SYSTEMS

Section PERIMETER SECURITY SYSTEMS Section 28 16 43 PERIMETER SECURITY SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Provide and install a perimeter security system as herein specified for the purpose of detecting entry into a designated security

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System SHIFT TEST BACK ENTER C910 SERIES STATUS OUTPUT ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM ACS-30 System MONITOR CONFIG POWER CONTROL MODULE ACCS-PCM-5 PROGRAMMABLE SINGLE POINT HEAT-TRACING CONTROLLER

More information

Architectural and Engineering Specification for a. Flash / Flare

Architectural and Engineering Specification for a. Flash / Flare Architectural and Engineering Specification for a Flash / Flare June 27, 2014 Page 1 of 12 T1DA0115-001 Rev D This document is intended to provide performance specifications and operational requirements

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

INTREPID Perimeter Intrusion Detection System

INTREPID Perimeter Intrusion Detection System TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.

More information

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT Simply Features In Brief Telemetry Ready Security 2 or 3 Pump Control UL Listed Alarm/Event Log Volumetric Flow Calculator VFD Control Optional Dialer

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications Non-contact Thermometers Portable Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio Temperature range from -58 to 1832 F (-50 to 1000 C)! Built-in

More information

STRIKE GUARD DELIVERS:

STRIKE GUARD DELIVERS: TM Strike Guard employs state-of-the-art technology to address the most demanding lightning safety and equipment protection applications. Designed for critical industrial applications, Strike Guard monitors

More information

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories TECHNICAL BROCHURE BCALARM R4 Indoor and Outdoor Panels and Accessories FEATURES Indoor and Outdoor alarm panels for sump, effluent and wastewater systems as well as test panel for troubleshooting. Use

More information

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm General Description & Applications The TCA-9102 Series Temperature Controller with Alarm offers a versatile solution for a

More information

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms Installation Guide franklinfueling.com 3760 Marsh Rd. Madison, WI 53718, USA Tel: +1 608 838 8786 Fax: +1 608 838 6433 Tel: USA & Canada +1 800 225 9787 Tel:

More information

When reliability is vital. Alemite Carbon Shield TM Systems deliver

When reliability is vital. Alemite Carbon Shield TM Systems deliver CATALOG 2 When reliability is vital. Alemite Carbon Shield TM Systems deliver Atomized Oil Lubrication system for rotating machinery bearings, gears and chains. Proven in refineries, petro-chem plants,

More information

AS950 REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS AS950 REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Refrigerated Sampler makes programming,

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the Radiant Warm Wall Compact Incubator Reduced Oxygen Incubator Automatic Water-Jacketed Incubator, stacked For more than 45 years, Lab-Line has been on the cutting edge of incubator development. Not only

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

Automatic Tank Gauging and Line Leak Detection System Bid Specification TS-550evo Fuel Management System

Automatic Tank Gauging and Line Leak Detection System Bid Specification TS-550evo Fuel Management System Automatic Tank Gauging and Line Leak Detection System Bid Specification TS-550evo Fuel Management System Franklin Fueling Systems 000-1739 r3, November 2017 An ISO 9001 Registered Company Part 1 General

More information

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System FEATURES: HIGH GAMMA SENSITIVITY MULTI-CHANNEL ANALYZER (MCA) WORKS WITH VARIETY OF PROBES RADIONUCLIDE LIBRARY TAILORED TO CUSTOMER REQUEST SIMULTANEOUSLY MEASURES ; DISPLAYS; ALARMS 1-3 SEPARATE DETECTORS

More information

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR The EMS510 provides continuous, low maintenance, precision measurement of Opacity and Dust (mg/m3). It is designed for monitoring visible smoke in the exhaust

More information

Model A2100 Series Annunciator

Model A2100 Series Annunciator Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended

More information

Pump-Up Controller MODEL 4062

Pump-Up Controller MODEL 4062 Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up

More information

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The

More information

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES 1,200,000 TO 3,000,000 GRAINS CAPACITY WATER SOLUTIONS * CUSTOM ENGINEERING * INDUSTRIAL PERFORMANCE (Single, Twin, Triple or Quadruple Demand Systems)

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

Aquapurification.com. Ozone. Ozonation Process: SGA Series: Ozone/Oxygen Systems:

Aquapurification.com. Ozone. Ozonation Process: SGA Series: Ozone/Oxygen Systems: The discovery and benefits of ozone dates back well over 100 years. Recent developments in technology have allowed a new generation of applications and products, using ozone, to emerge. Ozonation Process:

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

ACT2-CS Convenience Store Controller

ACT2-CS Convenience Store Controller Refrigeration Systems Technical Manual 804 Product Bulletins Section Product Bulletin Issue Date 0899 ACT2-CS Convenience Store Controller The ACT2-CS Convenience Store Controller is a fully programmable,

More information

LORAIN CIP 4890/48120 DC Power System

LORAIN CIP 4890/48120 DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet

More information

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749 RICHMOND, ONTARIO CANADA

More information

Pump-Down Controller MODEL 4052

Pump-Down Controller MODEL 4052 Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

Maxline 2 Thermal Imaging Solutions for Manufacturing

Maxline 2 Thermal Imaging Solutions for Manufacturing Maxline 2 Thermal Imaging Solutions for Manufacturing For automated Process Control and Process Inspection applications IRCON Maxline 2 Thermal Imaging and Analysis Solutions The Maxline 2 infrared thermal

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

Analog Input Module IC670ALG630

Analog Input Module IC670ALG630 1 IC670ALG630 The Thermocouple (IC670ALG630) accepts 8 independent thermocouple or millivolt inputs. Module features include: Self calibration Two data acquisition rates based on 50 Hz and 60 Hz line frequencies

More information

Electro-Sensors is revolutionizing the way hazard monitoring is done, with its turnkey HazardPRO TM systems. Rugged sensors and the most advanced

Electro-Sensors is revolutionizing the way hazard monitoring is done, with its turnkey HazardPRO TM systems. Rugged sensors and the most advanced Electro-Sensors is revolutionizing the way hazard monitoring is done, with its turnkey HazardPRO TM systems. Rugged sensors and the most advanced wireless technology combine to create the best hazard monitoring

More information

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available Pressure Drop Advantage Dual Flow Activation

More information

Controlled Environment Equipment Solutions for the Lab

Controlled Environment Equipment Solutions for the Lab Controlled Environment Equipment Solutions for the Lab Forma Reach-In Incubator Analyze Detect Measure Control Features and Technical Specifications Forma Reach-In Incubator Uniform Performance High Capacity

More information

Controllers. Instruction Manual WARNING

Controllers. Instruction Manual WARNING Controllers Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of

More information

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314) Mass Sensors, Inc. 1350 Baur Blvd, St. Louis, MO 63132 (314) 997-5779 www.mass-sensors.com Innovations in chemical microsensors Profile Mass Sensors is a development stage high-tech company operating in

More information

Using the DewTrak II Dew Point/ Humidity Transmitter

Using the DewTrak II Dew Point/ Humidity Transmitter APPLICATION NOTE 2016_FEB2 DT Rev 10 Using the DewTrak II Dew Point/ Humidity Transmitter The Model DewTrak ll Dew Point/Humidity Transmitter is a compact, cost effective, optical chilled mirror hygrometer.

More information

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview Micro SCM Streaming Current Monitor A Watts Water Technologies Company Instrument Overview The instrument consists of the Analyzer and the SCM sensor. Analyzer The Analyzer The monitor has a built in graphic

More information

Instruction Manual WARNING

Instruction Manual WARNING Controllers Instruction Manual WARNING THIS MANAUL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

ClampOn DSP Corrosion- Erosion Monitor

ClampOn DSP Corrosion- Erosion Monitor ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Corrosion- Erosion Monitor DIGITAL SIGNAL PROCESSING ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Corrosion-Erosion Monitor The patented ClampOn DSP Corrosion-Erosion

More information

wireless. web-based. worthy of the name RACO.

wireless. web-based. worthy of the name RACO. wireless. web-based. worthy of the name RACO. reliable monitoring unequalled accessibility on-demand reporting wireless, web-based alarm detection and notification system from RACO designed specifically

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System.  BU 04M01A02-01E-A Y-Plant Alert Alarm Annunciator and Sequence of Event Recording System BU 04M01A02-01E-A www.yokogawa.com/us Y-Plant Alert TM Alarm Annunciator and Sequence of Event Recording System Mission critical facilities

More information

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel mount and Remote Detectors (R) (353 and 353R) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

Omniguard 4: Features

Omniguard 4: Features OMNIGUARD 4 The clear choice for monitoring and documenting Vacuum and Pressure in a containment area. Ideal for Asbestos, Lead and Mold abatement and Clean Room monitoring. Omniguard 4: Features The Omniguard

More information

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES USER INSTRUCTIONS FOR THE CHEMGARD INFRARED GAS MONITOR SERIES To completely customize the specification to your exact application, modification to the

More information

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features: Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package. Patented

More information

RACK MONITORING SYSTEM - RAMOS Ultra

RACK MONITORING SYSTEM - RAMOS Ultra CONTEG DATA SHEET version: 9-05-0 COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM marketing@dafnia.com www.dafnia.com ABU DHABI UAE +97 55575 DUBAI JAFZA +97 4 5995 +97 4 8840 MUSCAT DOHA OMAN +968 4 75005

More information

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement DETECTABLE Gases: Sensor LS-1 R134a Sensor LS-2 R22 Sensor LS-3 CO 2 Sensor LS-4 R134, R404, R407, R410 Sensor LS-5 R134, R404, R407, R410,

More information

FMP-DIS & FMP-EIS. Interstitial BriteSensor & Standard Sensor. Installation Instructions

FMP-DIS & FMP-EIS. Interstitial BriteSensor & Standard Sensor. Installation Instructions FMP-DIS & FMP-EIS Interstitial BriteSensor & Standard Sensor Installation Instructions FMP-DIS Sensor FMP-EIS Sensor Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800

More information

LORAIN CSP DC Power System

LORAIN CSP DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable. ATSTORM v2 ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and highly reliable The storm detector ATSTORM v2 basic configuration

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

CHECKFIRE 210 Detection and Actuation System

CHECKFIRE 210 Detection and Actuation System DATA SHEET CHECKFIRE 210 Detection and Actuation System Features Supervised power, detection, release, and communication circuits Display module with LED system status indicators Adjustable mounting bracket

More information

Temperature Solutions Line Card

Temperature Solutions Line Card Solutions September 2015 We re Your One Stop Temp Shop One simple model number is all it takes to order our complete, Ready-to-Install Assemblies. They include your choice of: Universal PC-Programmable,

More information

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics

More information

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors Plant Wide Monitoring System for Bucket Elevators & Conveyors APPLICATION Combined belt alignment, belt speed, continuous bearing temperature, pulley alignment, level and plug condition monitor for bucket

More information