1 Infrared Business Tips & Insight 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only
2 Infrared Business Tips & Insight Presenter: Jay Bowen, Infrared Training Center. With increasing energy costs, thermal imaging cameras have quickly become prevalent for commercial and residential building inspection. Understanding the process of applying thermography and performing surveys efficiently and profitably is covered. This session will explore the numerous applications for thermal imaging technology beyond inspecting building envelopes. Discovering markets and revenue streams that augment the infrared building inspection are discussed. Examples will be given for each application and the basic conditions required Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 2
3 This is not new techniques! 1971 Home inspection with an AGA Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 3
4 Or An outdoor inspection 1969 AGA Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 4
5 Your Presenter Jay Bowen Electrician/ Engineer 32 years Thermographer 15 years Level III Master Electrician - Wisconsin Certified Electrical Inspector - Wisconsin Designer of Electrical Systems - Wisconsin Associate Degree Electronics Technology Electrical Contractor Business owner Involved in construction since 1977 Designed & Built one of the highest rated energy star homes in Wisconsin Green Bay, Wisconsin Packer Fan (season ticket holder), 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 5
6 Why IR Building Inspections? Building performance Insulation verification Locate air leakage Structural verification Moisture intrusion 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 6
7 What Can Infrared Thermography Find? Moisture Moisture Location(s) (Mapping) Evaluate Window Testing without Demolition Evaluate Roof Condition (ASTM C1153) Wall Condition Framing locations Pipe or duct locations Insulation Condition (ASTM C1060) Effectiveness (R values) Gaps Air infiltration Location of air infiltration during air test Electrical or Mechanical Problems 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 7
8 Seeing Through Walls??? Infrared cameras are NOT X-ray machines and cannot see through common materials. They image thermal energy from surface temperatures Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 8
9 Tools Blower Door Ammeter Anemometer FS Mirrors Moisture Meters Borescope 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 9
10 Topics to Understand The Electromagnetic Spectrum Infrared and Visible Spectrums Infrared Detection Devices Modes of Heat Transfer Radiation Conduction Convection Evaporation Thermal Capacity Thermal Image Interpretation Patterns Artifacts 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 10
11 Tip #1 Camera Selection???? 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 11
12 Choosing a camera Choosing a camera from the many available is a complicated task. Identify some important parameters Define some of the terms 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 12
13 Camera Resolution Camera resolution is the ability for the camera to detect and measure targets of a specific size Expressed in a multitude of ways as IFOV MFOV SSR Do all of these terms mean the same thing? 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 13
14 Camera terms IFOV (instantaneous field of view) smallest object that an imager can detect ( see ) but not measure accurately, expressed in milliradians The instantaneous FOV (IFOV) is a measure of the spatial resolution of a camera's focal plane array (FPA) detector and stated in terms of individual detector elements or pixels. For example, an FPA with 120 x 120 individual detectors has a total of 14,400 pixels Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 14
15 Camera terms MFOV (measurement field of view). The smallest object that an imager can measure accurately, expressed in milliradians (usually a multiple of the IFOV of the camera) MFOV IFOV 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 15
16 Camera terms SSR (spot size ratio). Used to calculate the maximum distance one can be from the camera to an object of a specific size to accurately measure it. SSR = D s = 1 MFOV D s 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 16
17 Camera Selection Regardless of which parameter is being discussed, they are all dependent on the imagers detector: Pixel density of the detector 80 x x x x x x x 480 Angle view of the lens attached to the camera Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 17
18 Let s Use a Visual Example The Effects of Pixel Density Camera Resolution Can You Tell What This Is An Image Of? Camera Selection How About Now? Getting Any Better? Better Yet? Are We There Yet? The BEST Highest Resolution! 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 18
19 Camera Selection 80 x 80 Camera resolution differences 120 x x x x 480 All images were captured at the same distance from the target 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 19
20 Camera Selection 80 x x x x 240 All images were captured at the same distance from the target 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 20
21 Camera Selection 140 x x 240 Additional framing from a removed window All images were captured at the same distance from the target 640 x Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 21
22 Camera Information IR image: a common size 200 x 150 pixels. Field of view depends on the distance between the camera and the scene. Visual image: 1536 x 1536 pixels (~2.3 mega pixels). How much can be seen in the image and resolved in detail. More pixel count generally means more detail from a given distance Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 22
23 Camera Specification Pixels (detector size) 140 x 140 Pixel size (IFOV) 2.10 mr Field of View (lens) 25º x 25º Focus NETD (sensitivity) Measurement Functions Close focus 0,12 m < 100 mk Spot, Alarm above/below, Dew point alarm, Insulation alarm Temperature Range(s) -20 C to 120 C, 0 C to 350 C Operating range - 15 C to 50 C Battery operating time ~ 5 h 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 23
24 Camera Specification Recommendations for a residential energy auditor: Detector not less than 120 x120. Low sensitivity but not higher than 100mK. FOV not less 20º. Pixel size or IFOV no larger than 3 mrad 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 24
25 Tip #2 - Lens Can the camera change lens? Common 25 Do I need additional lens? Telescopic 15 Wide Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 25
26 Lens Normal lens of 25 Wide angle lens of 45 Telescopic lens of Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 26
27 Lens Higher Res Lower Res Another reason for a lens is to capture a space or object in one image. Example shown; the space can t allow room to physically move further away to get this door in one image Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 27
28 Standards A technical standard is an established norm or requirement. It is usually a formal document that establishes uniform engineering or technical criteria, methods, processes and practices Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 28
29 Existing Standards - American ASTM C1060- [90 (2003)], Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings ASTM E 1186 [03], Standard Practice for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems ASTM C (Reapproved 2003), "Standard Practice for Location of Wet Insulation in Roofing Systems Using Infrared Imaging ASTM E , Standard Practice for Determining Air Leakage Rate By Fan Pressurization ANSI-ASHRAE 101: Application of Infrared Sensing. Devices to the Assessment of Building Heat. Loss Characteristics 800 RESNET Standard for Performance Testing 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 29
30 Tip #3 Delta T X2.1 Infrared inspection requires a sufficient difference in temperature from inside to outside ( T) for a sufficiently long period of time, to produce discernible differences between areas with studs and areas that may contain insulation. Indoor temp Outdoor temp Delta is "change". Delta T is (T in -T out ) 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 30
31 Delta T X2.2 Minimum temperature difference ( T) of 10 C (18 F) between interior and exterior surface or ambient air temperatures for a period of 4 h prior to test Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 31
32 Delta T Without a temperature difference the heat transfer through and around a wall does not occur and the image will lack contrast Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 32
33 Tip #4 Avoid Wind X2.3.2 Avoid Wind For exterior surveys, the wind speed should be less than 6.7 m/s (15 mph) and the building surface should be dry Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 33
34 Avoid Wind An inside look at a small interior deficiency Exterior is 20 F and interior is 70 F Refrigerator gap 0 minutes 30 minutes A 3mph wind was placed on this area 60 minutes 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 34
35 Tip #5 Solar Influences X2.3.1 Avoid Solar Radiation No direct solar radiation on the inspected surfaces for approximately 3 h previous to the inspection for light frame construction and approximately 8 h for masonry veneer construction. T greater than 10 C reduces these times. Direct sunlight and other strong sources of thermal radiation make discrimination of uninsulated areas unreliable. Exterior surveys should be performed after sunset and before sunrise for best results Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 35
36 Solar 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 36
37 Solar 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 37
38 Solar 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 38
39 Tip #6 Air Flow Air flow through a building can have a powerful impact on comfort, expense, and air quality. Blower doors provide a way to quantify air flow and the resulting heat loss, along with a way to pinpoint specific leaks. The benefits of their use have been understood and documented enough that most professionals now consider them essential for effective (and costeffective) air sealing Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 39
40 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 40
41 Blower Door and Ducts 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 41
42 Tip #7 Heat Transfer SIP Construction Ceiling Wall 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 42
43 Water or Missing Insulation? 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 43
44 Window Failure Courtesy Bernie Lyon, ITC 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 44
45 Leaking Chimney 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 45
46 Water Intrusion Discovery Point of entry Visible leak 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 46
47 Tip #8 - Reports This is typically the only part of process the customer sees. It must be accurate and timely It should be concise and direct and include pertinent information 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 47
48 Reporting 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 48
49 Survey Data 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 49
50 Tip #9 An R Value Calculator Many Caveats to understand. Developed by Dr. Bob Madding of Infrared Training Center 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 50
51 How much does that cost me? No attic insulation ~R-3 Good attic insulation ~R-40 Assume 33X33 ft = 1000 sq ft Massachusetts weather Heating and AC Oil Heat 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 51
52 Energy savings estimate Enter Values Degree days found at: Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 52
53 Energy savings estimate $1400 View Results 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 53
54 Alternates to Auditing Electrical Mechanical Roofs Commissioning Quality control 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 54
55 Electrical Imaging Know your safety rules NFPA 70E specifically PPE criteria Know the equipment Fuses and breakers Oil filled vs. dry transformers Understand basic electrical knowledge Voltage levels Current relationship to resistance Understand thermography physics and science Reflection Emission Trefl or background Heat transfer Heat Capacity Material specific heats 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 55
56 Electrical Imaging Panel boards Cables and feeders 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 56
57 Electrical Imaging Why is this GFCI receptacle normal? But this regular receptacle not? 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 57
58 Electrical Imaging Why is this Motor normal? But this motor is not? 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 58
59 Know your safety rules Approach and guarding Know the equipment Bearing and sleeves Valve types Understand basic mechanical knowledge Torque and speeds Fluid flow dynamics Mechanical Imaging Understand thermography physics and science Reflection Heat transfer Emission Heat Capacity Trefl or background Material specific heats 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 59
60 Mechanical Imaging Blockage in a pipe at a flange Steam trap operation 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 60
61 Mechanical Imaging Bearing heat normal or not? Gear housing 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 61
62 Roof Deck Imaging Know your safety rules Access and guarding Know the roof material and underlayment Insulation Deck type Understand thermography physics and science Reflection Emission Trefl or background Heat Capacity Heat Transfer 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 62
63 Roof Imaging Inside Outside 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 63
64 Roof Imaging Aerial viewing On deck 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 64
65 Roof Imaging Ballasted Open 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 65
66 Commissioning Lime kiln operation at startup Building system startup 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 66
67 Commissioning Boiler house operation Subway rail power operation 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 67
68 Quality Control Grocery cooler food placement Asphalt paving 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 68
69 Quality Control Drywall sheet 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 69
70 Quality Control Solar collector 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 70
71 Summary There is an endless application list for thermal cameras and trained thermographers. Thank you and enjoy the thermal world!! 2010 Infrared Training Center. All rights reserved. Intended for use by Infrared Training Center customers and prospects only 71
RESNET Infrared Inspection Standard and Certification
RESNET Infrared Inspection Standard and Certification Rogge Miller Guaranteed Watt Savers John Snell Snell Infrared RESNET 2009 Slide #1 Infrared Standard & certification Why create a new standard? I don
More informationStandard for Infrared Inspection of Building Envelopes
Standard for Infrared Inspection of Building Envelopes 2016 Edition Infraspection Institute 425 Ellis Street Burlington, NJ 08016 www.infraspection.com Standard for Infrared Inspection of Building Envelopes
More informationGetting in the Zone with Zonal Pressure Diagnostics
Getting in the Zone with Zonal Pressure Diagnostics NYSCAA/NYSWDA Lake Placid June 2, 2017 Presented by: Al McMahon New York State Weatherization Directors Association On many projects, air sealing is
More informationThermography Report. For: (Client) at: (location)
Thermography Report A SAMPLE INFRARED REPORT INFRARED BUILDING EVALUATION For: (Client) at: (location) Thermography date: 01-01-2013 Thermographer: Dave Sawyer, ITC Level III TIR Outdoor temperature: (Temp)
More informationUSING INFRARED TECHNOLOGY TO DEFINE ENERGY SAVINGS OPPORTUNITIES. James L. Park Energy Conservation Specialist I-Star Energy Solutions
USING INFRARED TECHNOLOGY TO DEFINE ENERGY SAVINGS OPPORTUNITIES James L. Park Energy Conservation Specialist I-Star Energy Solutions Facilities are inundated with people selling devices and technology
More informationUsing Infrared for Residential Energy Surveys
Using Infrared for Residential Energy Surveys Dave McCullen Sumter Electric Cooperative Inc. ABSTRACT In the electric industry today, advising consumers on energy conservation has replaced selling energy
More informationSmart Fire Prevention
Smart Fire Prevention Using VIP Vision Thermal Cameras to Detect Fire Release 1.0 Contents 1 Introduction to Thermal Imaging... 2 2 Detecting Fires with VIP Vision Thermal Cameras... 3 2.1 Mode Selection...
More informationWHY IS BUILDING SCIENCE IMPORTANT?
OUTLINE Why Building Science is Important Building Science Key Components Controlling Air Flow Controlling Thermal Flow Controlling Moisture Flow ENERGY STAR Solutions Action Plan WHY IS BUILDING SCIENCE
More informationHOME PERFORMANCE ENERGY ANALYSIS
Certifed Home, Termite, Green & Commercial Inspectors HOME PERFORMANCE ENERGY ANALYSIS ON 1234 ANY STREET; PHOENIX, AZ PREPARED FOR: JOHN DOE JANUARY 23, 2009 BY: PAUL A. FURMAN, P.E., LEED-AP Hire the
More informationHow to set up a Successful Sustainable Mechanical Inspection Program using Infrared Thermography
ORGANIZADO POR: Wayne Ruddock Director, Advanced Infrared Resources How to set up a Successful Sustainable Mechanical Inspection Program using Infrared Thermography ORGANIZADO POR: Infrascanner 1000, a
More informationInfrared Inspection Reference Letters Commercial & Residential
Infrared Inspection Reference Letters Commercial & Residential Cascade Thermal Imaging, Inc. P.O. Box 2131 Redmond, WA 98073-2131 425-861-3887 www.cascadethermal.com ~ Infrared Inspection The Non-Invasive
More informationCase Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com
A Geothermal Energy Generation Facility Embraces Infrared Polymer Window Inspections By Dominique Capili, Spectrum Scientific Corporation (An IRISS Distributor) Overview: A prominent geothermal energy
More informationBroadening IR applications through using spectral filters
Broadening IR applications through using spectral filters Inframetrics-Europe, Meche/sesteenweg 277, B-1800 Vilvoorde, Belgium Tel. (32) 2 257 90 30, Fax. (32) 2 257 90 39, e-mail: guy.pas@inframetrics.be
More informationInfrared Survey Report
Infrared Survey Report Scope of the Survey The scope of the inspection and report is a limited, qualitative infrared survey of the thermal patterns detected on the surfaces in your building. It uses a
More informationHeat Transfer and Your Electric Bill
efinitions of Energy Heat Transfer and Your Electric ill (Lexile 740L) 1 Summer is hot in most parts of Texas. Temperatures outside can go over 100 F (38 ). fter being outside in this heat, it is so nice
More informationLeveraging Thermal Imaging for Gas Detection
Leveraging Thermal Imaging for Gas Detection Ed Kochanek, Eastern Region Sales Director and Mark Boccella FLIR Systems, Inc. 9 Townsend West Nashua, NH 03063 Ph: 866-379-4022 www.flir.com ed.kochanek@flir.com
More informationSOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY
SOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY 6/12/2010 Recent IR Thermography Developments Can Help Agenda: Infrared Cameras for Solar Cell Inspection Survey of current solar cell test methods New
More informationRESNET HERS Rater Sample Test Questions 2
RESNET HERS Rater Sample Test Questions 2 1. Which of the following is the best device for removing standing water from a crawl space? A. Dehumidifier B. Sump pump C. Air-to-air heat exchanger D. Crawl-space
More informationThe Art of Building Science
The Art of Building Science What is Building Science? Building Science seeks to apply the scientific fundamentals of building dynamics to the functional relationships between the house s components and
More informationDEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION
DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION Ching-Wei Chen 1, Chia-Ray Chen 1 1 National Space Organization, National Applied Research Laboratories ABSTRACT MWIR (Mid-Wave Infrared) spectroscopy
More informationAssessing HVAC Leak Damage with Infrared
Assessing HVAC Leak Damage with Infrared Dave Sawyer SAWYER INFRARED.com ABSTRACT Infrared technology can assess the amount of unseen damage that water leaks can cause to building materials. Infrared is
More informationAdelaide Homes Design Guide 4 - Winter warming
Adelaide Homes Design Guide 4 - Winter warming Adelaide's temperate climate means home warming is required during winter. There are many efficient heating systems. The most economical method, however,
More informationEnergy Saver 101: Home Energy Audits
Energy Saver 101: Home Energy Audits Take the first step to improving your home s energy efficiency: get a home energy audit. What is a home energy audit? A home energy audit helps you pinpoint where your
More informationDR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption. The physical testing
Vipac Engineers & Scientists DR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption The physical testing Sydney 16 August 2016 Introduction to Vipac AGENDA
More informationInfrared thermal imagers: A primer for HVAC technicians Application Note
Infrared thermal imagers: A primer for HVAC technicians Application Note Have you ever taken heat for an expensive failure after having performed routine maintenance? Have you ever wished for a crystal
More informationUPGRADES. [Energy Efficiency] Base Points
SmartRegs Prescriptive Pathway Property Address: Dates of Inspections and Updates: Inspector: Owner: Agent: 123 Boulder Initial Inspection Date: Update Date: 7/9/5 Scott Home Inspection Unit: Compliance
More informationIR IN MODERN TECHNOLOGY 1. Infrared Radiation in Modern Technology. Brian D. Dold. Brigham Young University - Idaho
IR IN MODERN TECHNOLOGY 1 Infrared Radiation in Modern Technology Brian D. Dold Brigham Young University - Idaho IR IN MODERN TECHNOLOGY 2 Abstract Infrared radiation (IR) is invisible to the human eye
More informationNAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency
NAHB Green Home Building Guidelines Energy Efficiency 3.1 Prerequisites 3.1.1 Home is equivalent to the IESS 2003 or local energy code. Conformance shall be based on plan analysis using software. 3.1.2
More informationINFRARED HVAC APPLICATION HVAC 101
INFRARED HVAC APPLICATION HVAC 101 John Cannamela Owner ISC Building Diagnostics HVAC Journeyman since 1989 Start up test and Balance since 1992 Level II Thermographer Level II Vibration Level I Eddy current
More informationWhite Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com
Reducing Arc Flash Risks with Electrical Maintenance By Martin Robinson, CMRP Level III Thermographer President, IRISS Inc. Abstract: Electrical accidents, such as arc flashes, happen daily; however, there
More informationAudit Date: Auditor: Jimmie Sparks Client Name: White Bear Lake Audit Phone: x123 Neighborhood Energy Connection
Audit Date: 01-13-2011 Auditor: Jimmie Sparks Client Name: White Bear Lake Audit Phone: 651-221-4462x123 Thank you for participating in the Xcel Energy Audit program. A Home Energy Audit is the important
More informationHome Performance Analysis
395 National Drive Suite 15 Burtonsville, MD 2866 www.efficienthomellc.com 31-476-768 FAX: 31-476-7717 info@efficienthomellc.com Home Performance Analysis ENERGY AUDIT REPORT Prepared For: Matthew Lesko
More informationSAMPLE. Home Energy Audit Report and Guide to Energy Efficiency. Proprietary information belonging to Lightly Treading, Inc.
Home Energy Audit Report and Guide to Energy Efficiency Provided by Xcel Energy and Lightly Treading, Inc. Xcel Energy Customer 123 Main St., Denver CO April 10 th, 2009 Thank you for choosing Xcel Energy
More informationEnergyGauge USA Release Notes
EnergyGauge USA 5.0.02 Release Notes The latest release of EnergyGauge USA, Version 5.0.02, provides new features and bug fixes. This version includes new features for HERS raters. Key features added since
More informationAutomated Infrared Thermography Complete Solutions from a Single Source
Automated Infrared Thermography Complete Solutions from a Single Source Temperature monitoring of processes Automatic surveying of thermal marks Early fire detection and site security www.infratec.eu Innovative
More informationVision for Optoelectronics in the Automobile Thomas M. Forest General Motors Research & Development
Vision for Optoelectronics in the Automobile Thomas M. Forest General Motors Research & Development Outline Optoelectronic Communications Intra-Vehicle Extra-Vehicle Object Detection (LIDAR) Optoelectronic
More informationReducing energy use, airstream heat gain, and condensate production
Steam humidification: Reducing energy use, airstream heat gain, and condensate production Updated! Includes analysis of stainlesssteel-shielded dispersion tubes. by Lynne Wasner and Jim Lundgreen, Senior
More informationSpotting and addressing potential process problems using thermal imagery Application Note
Spotting and addressing potential process problems using thermal imagery Application Note By John Pratten, Fluke Thermography Some technologies once used expressly for predictive maintenance (PdM) are
More informationSantanu Prasad Datta (Student) P. K. Das & S. Mukhopadhyay
Effect of Refrigerant Charge, Compressor Speed and Air Flow through the Evaporator on the Performance of an Automotive Air Conditioning System 15 th International Refrigeration and Air July 14-17, 2014
More informationEXPERIMENT NO. III AIR ENTRAINMENT INTO AN IRS DEVICE
Objective EXPERIMENT NO. III AIR ENTRAINMENT INTO AN IRS DEVICE To investigate air entrainment into a louvered infrared suppression (IRS) device experimentally on a laboratory scale set up both with cold
More informationApplication Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!
Microsanj LLC 3287 Kifer Road Santa Clara, CA 95051 Application Note Comparing Thermoreflectance (TTI), Infrared (IR), Near Infrared Emission (EMMI), and Optical Beam Induced Resistance Change (OBIRCH)
More informationENERGY STAR V2.5 & 3 Designed to Qualify AIA Annual Convention
ENERGY STAR V2.5 & 3 Designed to Qualify AIA Annual Convention Chesapeake Utilities Corporation DBA Florida Public Utilities Corporation HERS Rating
More informationElectric Energy PROJECT PLANNING GUIDE OBJECTIVES OF THE 4-H ELECTRIC ENERGY PROJECT 1. To develop effective 4-H leadership, character and citizenship
Electric Energy PROJECT PLANNING GUIDE OBJECTIVES OF THE 4-H ELECTRIC ENERGY PROJECT 1. To develop effective 4-H leadership, character and citizenship. 2. To learn more about electricity and its safe and
More informationENERGY & WATER EFFICIENCY: HOME ASSESSMENTS. Jim Riggins Monument, CO
ENERGY & WATER EFFICIENCY: HOME ASSESSMENTS Jim Riggins Monument, CO Overview Home Energy Efficiency Basics Sample Energy Audit Results The Professional Energy Audit Benefits of Energy Efficiency U.S.
More informationCertification of Thermographers
CFPA-E No 3:2011 F Certification of Thermographers CFPA-E -GUIDELINES FOREWORD The European fire protection associations have decided to produce common guidelines in order to achieve similar interpretation
More informationWagner Meters has been an industry leader for over 40 years, creating innovative top-of-theline moisture measurement equipment.
Home Inspection Tools: Why a Moisture Meter Is Essential Not all home inspectors have identical industry knowledge. Credentials and licensing may vary depending on which state you live in, but the recommended
More informationBasic Building Science insights for Spray Foam, HVAC and Moisture
Basic Building Science insights for Spray Foam, HVAC and Moisture Claudette Hanks Reichel, Ed.D. Professor and Extension Housing Specialist Director, LaHouse Resource Center When the blind leads the blind
More informationHow to spot and address potential process problems using thermal imaging
How to spot and address potential process problems using thermal imaging Application Note By John Pratten, Fluke Thermography In the past several years, thermal cameras have transformed from a specialist-only
More informationCase Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com
Custom Solutions for High Arc Flash Incident Energy and Interlocked Electrical Enclosures By Mark Bowling, Level II Thermographer, IRISS Inc. & Rick Miner, Level III Thermographer, Thermal Techniques Overview:
More informationFS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com
Model Infrared Food Thermometer FS-200 Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Display Description... 5 Operating
More informationSurface Acoustic Wave Technology based Temperature Monitoring of High Voltage and High Current Switchgear Boxes
Surface Acoustic Wave Technology based Temperature Monitoring of High Voltage and High Current Switchgear Boxes Summary Safety is a big concern when it comes to managing power distribution systems. High
More informationTASKS REGARDING COMBUSTION AIR
TASKS REGARDING COMBUSTION AIR DETERMINE IF THERE IS ENOUGH COMBUSTION AIR FOR THE TYPES OF APPLIANCES IN THE CAZ Use one of two methods, depending on appliance type and whether or not you have a blower
More informationNORTH TECHNICAL UNIVERSITY ENGINEERING SCHOOL OF APPLIED SCIENCE. Maintenance Electric Engineering TECHNICAL REPORT
NORTH TECHNICAL UNIVERSITY ENGINEERING SCHOOL OF APPLIED SCIENCE Maintenance Electric Engineering TECHNICAL REPORT THERMOGRAPHIC ANALISYS AS APPLIED TECHNIQUE OF PREDICTIVE MAINTENANCE IN THE ELECTRICAL
More informationThermal Imaging. White Paper: Secrets to a Successful Thermal Imaging-based Building Energy Audit
Electrophysics Resource Center: White Paper: Secrets to a Successful -based 373 Route 46, Fairfield, NJ 07004 Phone: 973-882-0211 Fax: 973-882-0997 www.electrophysics.com Secrets to a Successful -based
More informationREVIEW ON CONDENSER AIR LEAK TEST
Volume 119 No. 16 2018, 3197-3205 ISSN: 1314-3395 (on-line version) url: http://www.acadpubl.eu/hub/ http://www.acadpubl.eu/hub/ REVIEW ON CONDENSER AIR LEAK TEST 1 Neethu Sathyan M, 2 Dr.Golda Dilip,
More informationFLIR Optical Gas Imaging Camera Helps Improve Environment And Safety At Borealis Stenungsund
FLIR Optical Gas Imaging Camera Helps Improve Environment And Safety At Borealis Stenungsund Many petrochemical plants handle invisible gaseous hydrocarbons. Most of these gases pose some sort of safety
More informationFriday, September 25, 2015 Des Moines, IA. 12:45 1:45 p.m. OLDER BUILDING SYNDROME: IT DOESN T GET BETTER WITH AGE
Friday, September 25, 2015 Des Moines, IA 12:45 1:45 p.m. OLDER BUILDING SYNDROME: IT DOESN T GET BETTER WITH AGE Presented by Carl Morello AVP Safety and Health Zenith Insurance Company Thorough loss
More informationPro Eco-Energy. Home Assessment
Pro Eco-Energy Home Assessment Prepared for: Prepared by: Pro Eco Energy Andrew Aliferis PO Box 445 Scotland, PA 17254 717-446-0575 ABOUT THIS REPORT Your in-home evaluation was conducted on 2/12/2013.
More informationBSC Building America High Performance Homes: Today & Tomorrow. Peter Yost Senior Building Scientist
BSC Building America High Performance Homes: Today & Tomorrow Peter Yost Senior Building Scientist Building America homes... create energy efficient environments that: - are affordable to operate - use
More information6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)
INTERNATIONAL International Journal of Mechanical JOURNAL Engineering OF MECHANICAL and Technology (IJMET), ENGINEERING ISSN 0976 AND TECHNOLOGY (IJMET) ISSN 0976 6340 (Print) ISSN 0976 6359 (Online) Volume
More informationA WORLD WITHOUT DOWNTIME
ELECTRICAL INFRARED INSPECTION High temperatures may indicate excessive electrical resistance, failing components, ground faults, short circuits or other common problems in equipment that can lead to expensive
More informationT2SL technology for Mid-IR detectors
T2SL technology for Mid-IR detectors Linda Höglund Minerva Workshop June, 30 th 1 Outline Introduction Tasks in MINERVA Starting point: MW detectors 320 256 on 30 µm pitch Technologies developed in MINERVA
More informationLindsey Beane. Executive Summary
Executive Summary The purpose of this technical assignment is to compile lighting information and make an analysis about the existing spaces. This report will include a list of the equipment used, required
More informationHome Performance Energy Audit Report
BPI Certified Auditor: Homeowner: Address: Email: Utility Company: Post Audit Date: Jeff Metzger Sandra Kunz- Test In 1360 S Lawson Dr Apache Junction AZ, 85120 (480) 982-6757 none SRP Marshall Insulation
More informationNon-destructive testing Infrared thermographic testing General principles
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 10880 First edition 2017-02 Non-destructive testing Infrared thermographic testing General principles Essais non destructifs Essais thermographiques
More informationLife Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering
Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015 Peter McDonnell, PE, LEED AP BD+C McClure Engineering UL DAMPER TEST STANDARDS UL 555 - FIRE DAMPERS UL555S SMOKE DAMPERS UL555C CEILING
More informationAppendix A. Glossary of Common Terms
Glossary of Common Terms Glossary of Common Terms Absorption chiller A refrigeration machine using heat as the power input to generate chilled water. Adjustable speed drive A means of changing the speed
More informationIce Dam Symptoms and Solutions for a Cold-Climate Roof
Ice Dam Symptoms and Solutions for a Cold-Climate Roof Matt Dries Dr. Robert Seavey Assisted by Collin Coltman and Kristel Spiegelberg Sustainable Systems Management: Building Science and Technology University
More information1 Exam Prep Energy Efficient Building Construction in Florida Questions
1 Exam Prep Energy Efficient Building Construction in Florida Questions 1. What activates the pump on a thermosiphon solar hot water heating system? A. Holding tank sensor B. Collector sensor C. The difference
More informationERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.
ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD 90.1-2013 (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings July 7, 2017 The corrections listed in this errata sheet apply to ANSI/ASHRAE/IES
More informationThermal Imaging Camera Training Course
Thermal Imaging Camera Training Course The Basics A thermal imaging camera displays the temperature of objects by converting non-visible radiation in the infrared spectrum to something we can see: In this
More informationCCTV, HOW DOES IT WORK?
August 25, 2005 CCTV FLAME DETECTION Video flame detection is an attractive concept. We ve all heard the adage, seeing is believing. In short, we trust our eyes to deliver accurate information. New designs
More informationRESNET National Conference New Orleans, LA. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO
RESNET National Conference New Orleans, LA. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO rgalenmoore1@msn.com This Presentation s Goals What to look for during a Home Performance
More informationAir-Sealing Beyond the Attic
Air-Sealing Beyond the Attic Energy Design Conference Bob Pfeiffer February 26, 27, 2013 Experience. Innovation. Results. About WECC Proving the value of energy efficiency and renewable energy since 1980
More information1.1. SYSTEM MODELING
1 INTRODUCTION Electro-optical imaging system analysis is a mathematical construct that provides an optimum design through appropriate trade studies. A comprehensive model includes the target, background,
More informationHow SWIR Imaging contributes to the optimization of automatic quality control in the food industry
How SWIR Imaging contributes to the optimization of automatic quality control in the food industry 2013 Overview Xenics in Short New Architecture Products Line Overview Visionlink Infrared Seminar 2013
More informationPredictive Maintenance Training
Predictive Maintenance Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq This predictive maintenance
More informationHIGH TEMPERATURE CAMERA
HIGH TEMPERATURE CAMERA I. Abstract Monitoring of high temperature processes is a difficult and uncertain exercise. Because of the severity of the atmosphere traditional instruments decay and are not reliable.
More informationDS-2TD Thermal & Optical Network Bullet Camera
DS-2TD2836-50 Thermal & Optical Network Bullet Camera Introduction Hikvision DS-2TD2836-50 Thermal Bi-spectrum Network Bullet Camera is applied to perimeter defense and fire-prevention purposes in critical
More informationUnderstanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry
Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry Daniel Dettmers Industrial Refrigeration Consortium University of Wisconsin Madison Overview
More informationExperimental study of space cooling using ceiling panels equipped with capillary mats
Experimental study of space cooling using ceiling panels equipped with capillary mats Tiberiu Catalina and Joseph Virgone University of Lyon, France Corresponding email: tiberiu.catalina@insa-lyon.fr SUMMARY
More informationTechnological developments in infrared imaging: a fast growing market Dr. François Simoens, CEA-Leti, Marketing & Strategy Manager
Technological developments in infrared imaging: a fast growing market Dr. François Simoens, CEA-Leti, Marketing & Strategy Manager Outline As a reminder, main infrared applications and technologies IR
More informationOverview. Case Study 2008 Building America Prototype ICI Showcase House. Daytona Beach, Florida. Project Team: ICI Homes, Building Science Corporation
008 /009Building America Prototype ICI Showcase House Case Study 008 Building America Prototype ICI Showcase House Daytona Beach, Florida Project Profile Overview Building Science Corporation (BSC) collaborated
More informationSITE SYSTEMS: FANNIE MAE EXPECTED USEFUL LIFE TABLES (FMEUL)
SITE SYSTEMS: FANNIE MAE EXPECTED USEFUL LIFE TABLES (FMEUL) Basketball Courts 15 25 Built Improvements Playgrounds, Site Furniture, etc. 20 20 Catch Basin 40 40 Cold Water Lines 40 40 Compactors DHW Supply
More informationXEUS mirror calibration:
XEUS mirror calibration: The PANTER X-ray Test Facility: accommodation of optics with long focal lengths etc., Wolfgang Burkert, Gisela Hartner, Bernd Budau XEUS Workshop, ESA, ESTEC, Noordwijk, 05-06
More informationMWL Consulting Company
MWL Consulting Company NFPA Member since1990 Fire Service Section Fire Marshal (retired) Newport Fire Department Michael W. Leber 17 Whitwell Avenue Newport, RI 02840 Mobile Phone 401-439-5322 mlebernpt@aol.com
More informationVehicle Detection. Brief history of each detection. How they work. Discuss most used ones. Are other options
Vehicle Detection Brief history of each detection How they work Discuss most used ones Are other options What are detectors used for? Signalized Intersection Basic signal detection Vehicular presence (stop
More informationEnergy Upgrade California Home Upgrade Offered by The Energy Network
Energy Upgrade California Home Upgrade Offered by The Energy Network Who is The Energy Network? Local government organization Created by the California Public Utilities Commission Provides resources and
More informationLEARNING SPECIAL HAZARD DETECTION TYPES
LEARNING SPECIAL HAZARD DETECTION TYPES JUNE 2013 COPYRIGHT CLIMATEC SPECIAL HAZARDS DETECTION TYPES EXPLAINED STAGE ONE DETECTION - ACTIVE AIR SAMPLING\\INCIPIENT AND IN- VISIBLE SMOKE STAGE AIR SAMPLING
More informationBoiler Venting. Definitions, Theory and Applications. Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX
Boiler Venting Definitions, Theory and Applications Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX Gas Appliance Listings ANSI Z21 - Categorized Appliances Gas fired low
More informationHome Performance Energy Audit Report
BPI Certified Auditor: Homeowner: Address: Email: Utility Company: Post Audit Date: Jeff Metzger Richard Wooldridge- Test In 936 S Ocotillo Dr Apache Junction AZ, 85120 (602)321-6749 none SRP Marshall
More informationUtilizing Finite Element Analysis (FEA) for Flexible Heater Designs
Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs Ryan Mohs, Process Engineer, All Flex. Flexible heaters are commonly utilized in many different heating applications. Generally, these
More informationI am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we
I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we appreciate your taking the time to learn more about this
More informationWHAT S CHANGED WITH ANSI/RESNET/ICC STANDARD 380. Iain Walker, Residential Building Systems Group
WHAT S CHANGED WITH ANSI/RESNET/ICC STANDARD 380 Iain Walker, Residential Building Systems Group Contributors: Dean Gamble Bruce Harley Gary Nelson Dennis Stroer Joe Medosch Kristof Irwin Pat Murphy Warren
More informationSEE WHAT SAVING ENERGY AND MONEY CAN DO FOR YOUR BUSINESS.
COMMERCIAL Washington Incentives SEE WHAT SAVING ENERGY AND MONEY CAN DO FOR YOUR BUSINESS. COMMERCIAL GAS STANDARD INCENTIVES FOR BUSINESS CUSTOMERS OF NW NATURAL IN WASHINGTON EFFECTIVE JANUARY 2018
More informationI. STRUCTURAL SYSTEMS
I. STRUCTURAL SYSTEMS A. Foundations Type of Foundation(s): Pier & Beam - Crawlspace Opinion: All exposed areas of the foundation were examined visually. Examination of the foundation was limited to photographs
More informationSummary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000
SAE Alternate Refrigerant Cooperative Research Program Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000 To: Alternate Refrigerant Task Force Members From: Ward Atkinson
More informationMonitoring of Electrical Equipment Failure Indicators and Alarming
Past, Present and Future Maintenance Practices: Monitoring of Electrical Equipment Failure Indicators and Alarming Author: Gabe Paoletti, P.E. Eaton Corporation Senior Member, IEEE gabrieljpaoletti@eaton.com
More informationHome Energy Assessment Report
Home Energy Assessment Report Prepared for Prepared by Nathaniel Dick 50 Washington St Westborough, MA 01581 Assessment Date Powered by Conservation Services Group Assessment Summary About Your Home Year
More informationPublic Comment No. 3-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification
Public Comment No. 3-NFPA 1408-2013 [ Global Input ] Type your content here... NFPA 1408, Standard for Training Fire Service Personnel in the Operation, Care, Use and Maintenance of Thermal Imagers Revise
More information