LUXOMAT PD4/M PD4/S. SM Surface mount. FC Ceiling mount. FM Flush mount

Size: px
Start display at page:

Download "LUXOMAT PD4/M PD4/S. SM Surface mount. FC Ceiling mount. FM Flush mount"

Transcription

1 Operating and mounting instruction occupancy detector PD4/Master and Slave less effort, in particular in situations where there is a large number of occupancy detectors in use, such as, for example, in the case of large-scale SM Surface mount Thank you for purchasing the occupancy detector. You have opted for a quality product from the BEG range and for one which has been manufactured, tested, packaged and despatched with the utmost care. Please read the information contained in these directions before commencing assembly. Allocation of the article numbers: Model SM FC FM PD4/M Master FC Ceiling mount LUXOMAT PD4/S Slave We reserve the right to make any technical adjustments which are in the interests of productimprovement. Important: All work on the 230V power system must be carried out by qualified personnel only! The mains voltage must be cleared prior to commencement of assembly of the LUXOMAT. With its infrared remote-control system, BEG is one of the first manufacturers worldwide to facilitate control and programming of a occupancy detector using telecontrol technology. This does away with the need for erecting a ladder, and the setting of the presence-detector parameters can be carried out with considerably R L' N L - L Slave/Remote NO NO FM Flush mount 3A 25 office buildings. Unlike the motion detectors designed for external use which have dominated the sector up to now, occupancy detectors are considerably more sensitive and, as such, are particularly suited for internal applications; in addition to moving activity, they will also pick up activity of a sedentary nature. Designs PD4/M PD4/S LUXOMAT PD4 ceiling-mounted occupancy detectors are available in designs intended for both surface- (PD4-SM) and flush-mounted (PD4-FM) installation as well as for built-in ceiling installation (PD4-FC). No further steps require to be taken in the case of the models which have been designed for surface-mounted installation; they can quite simply be installed on any level surface. The models which are intended for flush-mounted installation are compatible with conventional inlet sockets. All of the appliances are available both as a Master and a Slave version: Master The occupancy detectors LUXOMAT PD4 Master feature 2 relay contacts, which may be set independently of each other. Contact 1 triggers the lighting, reacting to movement and ambient degrees of brightness. Contact 2 is voltage-free and will trigger any number of appliances as a reaction to movement. The Master-appliance has extensive possibilities when it comes to setting the control function for both lighting and the appliances. These possibilities are covered in detail in the Operating Instructions. Slave The occupancy detectors LUXOMAT PD4 Slave can only be operated in conjunction with a Master-appliance. Any number of Slave-appliances can be connected up to a Master-appliance for the purpose of extending the area of coverage without incurring significant expense. Slave-appliances cannot be set independently. All setting-work is carried out on the LUXOMAT PD4 Master.

2 Detecting movement The motion-detector feature of the installation centres around a visual system which has been designed and developed to an exceptionally high electronic and optical standard. The infrared beam which is radiated from moved or moving objects is directed straight at a pyroelectric sensor via the hemispherical Fresnel lens. Automatic light control (PD4 MASTER) Function The light is switched on automatically in the operating mode Fully Automatic once movement is detected and a pre-set minimum degree of brightness (switch-on value) is not achieved, just as it is switched off automatically in the absence of movement or when a pre-set maximum degree of brightness (switch-off value) is exceeded. It is possible to program either the switch-on or the switch-off value. If it is the switch-on value which is pre-set, the detector will calculate the switch-off value automatically, and vice versa. When the system is in the operating mode Semi-automatic, it is always necessary to switch on the light by hand, either using the switch provided or by remote control. In so far as there is no detection of movement at the same time, the degree of brightness at any given time is indicated as follows with the assistance of light-emitting diodes (LED s) in the appliance: Appliance identifies bright : LED flashes at a steady rate Appliance identifies dark : LED does not flash at all Additional information: In order to avoid situations where switching-on and switching-off occurs unnecessarily, the reaction on the part of the appliance to any change in the degree of brightness is triggered on a time-delayed basis. Passing cloud, for example, would suffice to cause unnecessary switching. Time-delay bright dark : 30 seconds Time-delay dark bright : 5 minutes Learning process The system features a learning process, which enables the detector to take into consideration the fact that the illuminating power of fluorescent lamps is not yet fully developed at the beginning of their service life, and likewise their illuminating power deteriorates with age. Once the switchon value has been preset, the detector switches on the light repeatedly for periods of 5 minutes regardless as to whether it has detected any movements, and then switches it off again until such time as the fluorescent lamps have developed their full illuminating power. It is, however, also possible to get around having to carry out this process 26 (see Automatic memorizing function of the current twilight value for light control ). Manual light control (PD4 MASTER) Regardless of the availability of light at any given time, the light can be switched on or off manually using the remote-control facility or a contact switch located at the input R (impulse 0.2 to 0.5 sec.). Important: Appliance must be closed (see Closing the PD4 Master ). Switching on using remote control or switch The light will remain switched on for as long as movements are detected in the areas of coverage. Once the last movement has been detected, the light will remain on for the duration of the followup time as per setting. The appliance will then return independently to the mode selected. (Fully or Semi-automatic). Where the appliance has already identified the condition bright prior to the lighting being switched on manually, the level of brightness will not be monitored after switching-on has taken place. Where the appliance has already identified the condition dark prior to the lighting being switched on manually, the level of brightness will be monitored after switching-on has taken place, and the lighting will be switched off following a delay of 5 minutes once the switch-off value has been exceeded. Switching off using remote control or switch The light will remain switched off for as long as movements are detected in the area of coverage. Once the last movement has been detected, the light will remain off for the duration of the follow-up time as per setting. The appliance will then return independently to the operating mode selected. (Fully or Semi-automatic). Automatic appliance control (PD4/M) Other consumers such as ventilation installations or alarm devices can be controlled via a voltage-free switch-output. This relay operates strictly on the basis of reaction to movement and can be equipped, for the purpose of safety applications and with enhanced protection against false alarms, with a delayed switch-on function to drive ventilation installations. Parallel- or Master/Slave operation The LUXOMAT PD4 Master can operate either on its own or together with other detectors. Parallel operation involving several PD4/M As the PD4/M occupancy detector is equipped with an ingeniously logical capacity for measuring brightness and a facility for controlling light on the basis of presence, it is not recommended that it be

3 operated in parallel with other Master-appliances or motion-detectors. Please always select the Master/Slave mode of operation as described in the following for the purpose of extending the area of coverage by a Master-appliance. Master/Slave mode of operation Any number of PD4 Slave s* can be connected up to a PD4 Master for the purpose of extending the area of coverage without incurring significant expense. All that the Slave-appliances do is to pass on information on movement to the Masterappliance. The PD4 Master measures the degree of brightness and, where appropriate, switches on the light and other appliances. Additional information: When in Master/Slave mode of operation, the Master-appliance must always be installed at the location where there is least daylight. *Any 220V motion-detector (e.g. LUXOMAT RCplus) connected up to the slave-input of a master will serve as an acceptable alternative to using a slaveappliance. For this purpose, the motion-detector must be set at daytime/night-time operation, ensuring a follow-up time of between 2 seconds and 1 minute. Assembly, commissioning Important: All work on the 230V power system must be carried out by qualified personnel only! The mains voltage must be cleared prior to commencement of assembly. Prior to mounting: Prior to mounting the unit please make sure of the following: LUXOMAT PD4 has to be fixed on a solid surface do not connect more than 2 LUXOMAT PD4 in parallel to avoid potential false switching. the connected load must not exceed the following ratings: resistive load 230VAC/10A max. inductive load 230VAC/5A max. the view of LUXOMAT PD4 must not be obscured by objects since those will block IR-radiation from being detected LUXOMAT PD4 is a dedicated automatic lightswitch and is not intended to be used in burglar alarm and intrusion detection systems. 3. Montage Determining the location of installation In order to guarantee flawless and satisfactory operation of the unit, the following characteristic of infrared motion sensors must be taken especially into consideration: Motion sensors switch most sensitively if movement occurs crossways to the line of the lens segments. During frontal approach, the sensitivity and therewith the effective detection range is greatly reduced. Installation of the LUXOMAT PD4-SM Disconnect mains supply! The detector must be installed on a solid and level surface. There is no need for frames. close open Example corridor: Reduced detection range Reduced detection range during during frontal frontal approach Bad 3-4 m appr. Optimal For mounting remove lens (C) (turn anticlockwise) Fasten the mounting pod to the ceiling. After installation replace the lens and lock (turn clockwise). After an initial 60-second self-test phase, the LUXOMAT PD4 is ready for operation. In case the sensing area of the LUXOMAT PD4 is too large or areas are being covered that should not be monitored, the range can be reduced or limited through use of the enclosed masking clips (e). C e 27

4 Installation of the LUXOMAT PD4-FC The detector has been designed and developed specifically for installation in suspended ceilings. For mounting remove lens (turn clockwise). A circular opening of diameter mm must first of all be produced in the ceiling. Having connected up the cables in accordance with regulations, the detector is inserted into the opening as shown in the drawing opposite and fixed into position with the assistance of the spring clips. open Installation of the LUXOMAT PD4-FM The detector can be installed in conventional inletsockets mounted on the ceiling. The assembly plate enclosed must be stripped off prior to installation and secured to the ceiling using 4 screws and ensuring that it is not laterally transposed. Having connected up the cables in accordance with regulations, the detector can be placed in position as shown in the drawing opposite and, applying a little pressure, can then be locked into position with the assistance of the spring clips. (Please refer to the connection diagrams of the Operating Instructions when connecting up the wiring) Commissioning the LUXOMAT PD4 MASTER close When installation has been completed and the 230V mains voltage has locked on, the red LED will flash for a period of 60 seconds, indicating that the LUXOMAT PD4 MASTER is in self-checking mode. Once this process of self-checking has been completed, the various settings can be carried out. With regard to this procedure, please refer to the chapter Settings without the use of remote control. If you have the remote control LUXOMAT IR-RC, which is available as an extra, please read the chapter on the next page Settings using remote control. Fully/Semi-automatic The Master-appliances leave our factory set for operating mode Fully automatic (see Automatic light control PD4 Master ). When commissioning has been completed and the 60-second period in self-checking mode is up, the system can, if required, be switched over to operating mode Semi-automatic, using the LUXOMAT IR-PD The following is the procedure required: 1. Open appliance Acknowledgement via connected lighting 2. Switch from operating mode Fully automatic to Semi-automatic or vice versa using the key Light ON/OFF Acknowledgement only via the red LED on the appliance as per the following: Semi-automatic: Rapid flashing of the LED for a period of approx. 3 seconds Fully automatic: LED lights up for a period of approx. 1.5 seconds 3. Close appliance Acknowledgement via connected lighting Commissioning the LUXOMAT PD4 SLAVE When installation has been completed and the 230V mains voltage has locked on, the green LED will flash for a period of 60 seconds, indicating that the LUXOMAT PD4 SLAVE is in self-checking mode. The detector is ready for service immediately after the process of self-checking has been completed. It is not possible to carry out settings on the PD4 SLAVE. Settings without the use of remote control (for PD4-Master only) Follow-up time for light control (relay 1) The time can be set infinitely variably at between 15 seconds 2 and 16 minutes. 1 Symbol : Impulse :< 1 second TEST Symbol TEST: Test mode (Every movement switches on the light for a period of 1 second, switching it off for a period of 2 seconds after that regardless of the level of brightness) Additional information with regard to the Impulse function: Please note when activating the Impulse function that the regular clicking of the relay could prove annoying depending on the application and location of installation of the appliance. Additional information: If the relay is not being 28

5 used for the purpose of light control, the follow-up time should be set at 16 minutes as otherwise the switching of the relay, which can be heard, could prove annoying. Twilight-switch for light control (relay 1) The switch-on value for the light can be set at between 40 and 2000 Lux. The switch-off value is calculated automatically. Symbol : Night-time operation Symbol : Daytime/Night-time operation Additional information in connection with fluorescent lamps: As soon as the pre-set switch-on value has been reached, the detector will switch on the light for a period of 5 minutes regardless as to whether or not movements have been detected, then switching it off again. This procedure is repeated until the fluorescent lamps have developed their full illuminating power, thus enabling the switch-off value to be calculated conclusively. Follow-up time for appliance-control (relay 2) A The time can be set infinitely variably at between 5 minutes and 120 minutes. There is a period of delay prior to switch-on of between 5-10 minutes for times set in excess of 15 minutes. Symbol : Impulse = 2 sec. (see Page 30 Additional information on the Impulse function ) Symbol A: Alarm impulse = 1 sec. (Enhanced protection against false alarms: The detector will not engage unless at least 3 movements have been registered within a period of 10 seconds). Additional information: If the relay is not being used for the purpose of appliance-control, the follow-up time should be set at 120 minutes as otherwise the switching of the relay, which can be heard, could prove annoying. Mode of procedure of follow-up times As soon as a movement is detected inside the area of coverage, the Master initiates the integrated timer. The consumers which have been connected up either become illuminated or run for the duration of the pre-set period of time. If further movements are detected within this period of time, the timer will be reset each time. Settings carried out using remote control (for the PD4 Master only) Remote control LUXOMAT IR-PD The infrared remote-control facility enables the LUXOMAT PD4-Master occupancy detector to be used to considerably greater effect when compared with more traditional applications. Important information on commissioning 1 2 TEST TEST Additional information: Before leaving the factory, Potentiometer 1 has been set at TEST and Potentiometer 2 at SUN. All values which have been programmed using the remote control will be deleted in the event of power failure in this position, i.e. before carrying out programming using the remote control, it is imperative that Potentiometer 2 be switched over to MOON or any other value. Acknowledgement of receipt Every signal which is validly received by the LUXOMAT PD4/M is acknowledged in the form of 2-second-long illumination of the red LED and is indicated by the connected lighting flashing. Commands which have not been accepted are indicated by illumination of the red LED of 0.5 seconds duration. Unblocking Every time connecting-up to the mains takes place, the PD4/M is blocked. This status makes it impossible to carry out settings using the remote control. In order to permit programming to be carried out, the occupancy detector has to be unblocked with the assistance of the remote control (see Opening the PD4 MASTER ) EEPROM (Memory) All of the values which have been set on the Master using the control knobs are overwritten by the remote control and stored in the EEPROM. In this way, the pre-set values remain preserved even in the event of a power failure. Additional information: When the 230V mains voltage has locked on, the red LED will flash for a period of 60 seconds, indicating self-checking mode. Flashing at intervals of one second = EEPROM empty Rapid flashing = EEPROM contains information 29

6 Battery The remote control is supplied complete with battery. Where teleadjustment is not possible, first of all check whether the battery has been correctly polarized (open battery compartment by pressing the plastic springs together and removing the battery-holder). If this does not solve the problem, the battery must be replaced. Setting the functions Opening the PD4 MASTER The PD4 MASTER is opened using this key and can then be programmed for the respective function using the remaining keys. Important: Must be actuated following every occurrence of a power failure, otherwise settings cannot be changed. Closing the PD4 MASTER The detector is protected against occurrences of inadvertent manipulation. When in this state, the only functions which can be actuated are RESET, Light On/Light Off and TEST. We must distinguish between this state and Permanent protection against sabotage (see also Page 30) Twilight-value for light control (relay 1) It is possible, on the basis of the standard values indicated, to set a specific switch-value for brightness. In the case of rooms which have access to daylight, the recommended setting is 300 Lux as opposed to a setting of 1000 Lux for rooms with no dayight. Any switch-value can be stored for brightness using the Automatic input function, which is described in the following. Automatic input function of the current twilight-value for light control (relay 1) Any value for brightness (approx Lux) can be read as the switch-value for the lighting using this function. Important: The appliance distinguishes between the following two methods of approach. We recommend: Inputting with lighting switched on. Additional information: Values which are too bright and too dark cannot be input (red LED flashes extremely quickly). Inputting with lighting switched on (recommended method) Having pressed the key, the current value for brightness is pre-set as the switch-off value. The switch-on value is calculated automatically. Method of approach: with the lighting switched on, wait for the exact point in time in the morning as of which artificial lighting is no longer required and then actuate the input-key. Inputting with lighting switched off Having pressed the key, the current value for brightness is pre-set as the switch-on value. The switch-off value is calculated automatically. Method of approach: wait for the desired degree of twilight in the evening and then actuate the input-key. Additional information in connection with fluorescent lamps: As soon as the pre-set switch-on value has been reached, the detector will switch on the light for a period of 5 minutes regardless as to whether or not movements have been detected, then switching it off again. This procedure is repeated until the fluorescent lamps have developed their full illuminating power. The learning phase can be shortened by inputting when the lamps have warmed up. No learning phase is required with the method Inputting with lighting switched on in so far as the fluorescent lamps have already developed their full illuminating power. Gong-program for light control (relay 1) The follow-up time is less than 1 second in this mode (impulse program). This program facilitates, for example, the triggering of any automatic stairwell-lighting systems or gongs. Each impulse is followed by idle time of 9 seconds duration, during which period no movements are registered. Additional information with regard to the Impulse function: Please note when activating the Impulse function that the regular clicking of the relay could prove annoying depending on the application and location of installation of the appliance. Follow-up time for light control (relay 1) The requested follow-up time for the lighting connected can be programmed to the very second by pressing the appropriate key. Follow-up time for appliance control (relay 2) The requested follow-up time for the appliances connected can be programmed to the very second by pressing the appropriate key. 30

7 Additional information: switch-on is automatically delayed by 5-10 minutes in the case of follow-up times in excess of 15 minutes (red ring), i.e. ventilation installations, for example, can be engaged with a time delay if movements are detected over a period of at least 5 minutes. Impulse program for appliance control (relay 2) The voltage-free contact is closed for a period of 2 seconds. This is followed by a period of idle time of 8 seconds duration. This facilitates, for example, the triggering of external alarm devices. Alarm impulse program for appliance control (relay 2) Is suitable wherever faulty switching is to be avoided at all costs. The relay will not close until at least three movements have been registered over a period of 10 seconds (impulse = 1 second). Test mode The area being monitored can be paced out regardless of the level of ambient brightness. Each movement switches the light on for 1 second, then switching it off for a period of 2 seconds. Permanent protection against sabotage This function blocks the LUXOMAT PD4 MASTER permanently (green LED is illuminated). This operating mode can only be activated during the period of 5 seconds following closure of the detector. This status will only permit actuating the function Light on/light off. The procedure for leaving this mode is as follows: 1. Switch off the current 2. Apply current for seconds 3. Switch of the current again 4. Apply current 5. Open detector (see Opening the PD4 ) Fully/Semi-automatic Light on/light off when open When commissioning has been completed and the 60-second period in self-checking mode is up, the system can, if required, be switched from operating mode Fully automatic to Semi-automatic or vice versa, using the Light ON/OFF key (see Fully/Semi-automatic ). Light on/light off when closed The light can be switched off and on at any time using the remote control. The appliance will then return independently to the mode selected. (Fully/Semi-automatic). Light on The light will remain switched on for as long as movements are detected in the areas of coverage. Once the last movement has been detected, the light will remain on for the duration of the follow-up time as per setting. The appliance will then return independently to the mode selected. (Fully or Semi-automatic). Where the appliance has identified the condition bright prior to the lighting being switched on manually, the level of brightness will not be monitored after switching-on has taken place. Where the appliance has identified the condition dark prior to the lighting being switched on manually, the level of brightness will be monitored after switching-on has taken place, and the lighting will be switched off following a delay of 5 minutes once the switch-off value has been exceeded. Light off The light will remain switched off for as long as movements are detected in the area of coverage. Once the last movement has been detected, the light will remain off for the duration of the follow-up time as per setting. The appliance will then return independently to the operating mode selected. (Fully or Semi-automatic). Resetting when open All values which have been programmed using the remote control IR-PD are deleted, and those values in the PD4/M which have been set by potentiometer are activated. Additional information: The switch-off threshold requires to be re-learned or input. Resetting when closed Both the relay for the lighting and the relay for the appliances are switched off, i.e. opened and the follow-up times reset. 31

8 LED-functional indicators, fault-finding The functional indicators in the case of the LUXOMAT PD4 MASTER (red and green LED s) Red LED indicating self-checking mode (over a period of 60 seconds following mains -supply lock-on) Flashing at intervals of 1 second EEPROM/memory empty Flashing rapidly EEPROM/memory contains information Red LED as an indicator of status Flashing irregularly Flashing regularly Not illuminated Flashing extremely rapidly Movements are detected within the area of coverage Detector identifies bright light off (dependent upon operating mode) Detector identifies dark light on (dependent upon operating mode) Too bright/too dark/undfined Red LED as an acknowledgement of receipt for commands from the remote control Illuminated for 2 seconds Signal validly received Illuminated for 0.5 seconds Not-accepted command, detector blocked Flashing extremely rapidly not-accepted command, occurs, for example, when an attempt is made to input twilight-value are too bright or too dark Green LED as an indicator of status (only for status Permanent protection against sabotage ) Flashing irregularly Movement are detected within the area of coverage Flashing regularly Detector identifies bright light off (dependent upon operating mode) Not illuminated Detector identifies dark light on (dependent upon operating mode) Green LED as an acknowledgement of receipt for commands from the remote control Illuminated for 2 seconds Signal validly received (only possible for function Light on/light off ) Possible types of malfunction Light not illuminated Light illuminated constantly during darkness Light illuminated constantly, also during the day Detector switches off again approx. 5 minutes after switching on lighting then switching on again automatically The function Light on/light off is not working Cause Twilight-value not reconcilable with the given situation Function Light off activated Constant heat activity in the area of coverage Function Light on activated Twilight-value not reconcilable with the given situation Fluorescent lamps are connected up. The detector is going through a learning phase. The relay for the light control is set at Impulse function Rectification Adjust twilight-value with regulating screw or remote control Actuate Light on on remote control If movements caused by sources of interference (animals, ventilation, etc.), remove from area of coverage Actuate Light off and/or Reset using remote control or appropriate key Adjust twilight-value with regulating screw or remote control This ceases to occur once the learning phase has been completed (approx. 10x on/off) Using the remote control, this learning phase can be shortened or even avoided Select follow-up time for light control of between 15 seconds and 30 minutes (Please note: could destroy other appliances which are connected, e.g. automatic stairwell-lighting systems) Despite perfect functioning of the PD4, a relay is heard switching constantly Other forms of malfunction during programming with IR-RC R1 or R2 on Impulse function Appliance output R2 is not being used, but is set at a short follow-up time Light output R1 is not being used, but is set at a short follow-up time 32 If possible, select continuous contact Set follow-up time for appliance-control R2 at 120 minutes Set follow-up time for light control at 30 minutes Open appliance and then actuate RESET key and re-program

9 Remote control Accessories LUXOMAT IR-PD Remote control for convenient teleadjustment and programming of the PD4 occupancy detectors with wallmounted holding device as standard Art. No LUXOMAT IR-PD-mini Small remote control for the enduser. Functions: Automatic ON/OFF Art. No LUXOMAT IR-PD WH Wall-mounted holding device for infrared remote control IR-PD (comes as standard with the LUXOMAT IR-PD) Art. No LUXOMAT BSK Protective cage: protects the occupancy detector damage caused by balls or vandalism. Art. No Detection area Detection area walking activities for PD4 Fixing height 2.5 m Sideview 6.4 m 8 m 24 m Detection area sitting activities for PD4 walking across walking towards seated Topview 33

10 Wiring diagrams Terminal connection for standard operation Standard operation with external push button HAVC HAVC Standard operation Standard operation, manual switching possible (NO-contact to be pressed for approx. 1 sec.) The potentiometers not to be set on Test or Sun otherwise the preadjusted values will get lost during this manual operation. Terminal connection for master-/slave-operation L N HAVC Terminal connection for master-/slave operation L N MASTER SLAVE MASTER R 2 MASTER/ SLAVE-MODE R L' N N L L N N L L R R R L' N N L L R L' N N L L Master/Slave-operation with one master and several slaves. The master is the only unit to read in the lux levels and to switch the connected loads. The slave units will react on motion only, independently of the lux levels, by sending an impulse via the dry contact. Master/Slave-operation, i.e. masters operate as slaves but with additional push button function to switch the light manually. The preset values will not get lost. The master is the only unit to read in the levels and to switch the connected loads. The slave units will react on motion only, independently of the lux levels, by sending an impulse via the dry contact. Terminal connection for parallel-operation HAVC HAVC The parallel-operation is not allowed for master units! 34

11 Technical data PD4-Master Sensor an power supply in one case for onwall-, ceiling- and flushmounting Electrical data Voltage 230V~ + 6%/-10% Power consumption < 1W Ambient temperature -25 C to +50 C System of protection SM = IP54, FC/FM = IP20 Protection class II Modes of operation Settings locally and by remote control Light values Inputting of current light value Parallel operation Master/Slave Area of coverage circular 360 Range of coverage Ø H 2.5m/T=18 C seated 6.40m / walking across 24m / radial 8m Recommended fixing height 2-3 metres Light measurement Mixed light, i.e. daylight + connected, artificial light Lux values lux Relay/Channel 1 for light-connection Type of contact NOC/Normally open contact Contact load 2300W, 230V~, 10A cosϕ=1, 1150 VA cosϕ=0.5 Max. no. of series-connected electronic depending on type and make, total connectable140µf. appliances 30 x 18W single-flame 20 x 18W dual-flame 25 x 36W single-flame 20 x 36W dual-flame 20 x 58W single-flame 10 x 58W dual-flame Time-setting Impulse, 15 seconds - 30 minutes Relay/Channel 2 (for connection of other loads) Dry contact type NO 3A 5 sec. Impulse or 5 to 120 min., with time delay of 10 min. Dimensions HxØ SM FC FM 73x x97 84x97 Separate input terminal for push button Declaration of Conformity: The product complies with the low voltage recommendation 73/23/EWG and the EMV recommendation 89/336/EWG Technical data PD4-Slave Electrical data Voltage 230V~ + 6%/-10% Power consumption < 1W Ambient temperature -25 C to +50 C System of protection SM = IP54, FC/FM = IP20 Protection class II Area of coverage H 2.5m/T=18 C circular 360 Range of coverage Ø seated 6.40m / walking across 24m / radial 8m Dimensions HxØ SM FC FM 73x x97 84x97 Declaration of Conformity: The product complies with the low voltage recommendation 73/23/EWG and the EMV recommendation 89/336/EWG 35

12 Warranty for BEG LUXOMAT products BEG products are produced using state-of-the-art technology and are quality tested. Should a fault arise in spite of this, BEG GmbH provides the following warranty: a) Term The term of the warranty is 36 months following purchase of the unit by th customer. b) Scope The unit shall be repaired of manufactured once again free of charge by BEG in its factory at its discretion if it is proved that a manufacturing of material fault has rendered it unsuitable for use or hase considerably limited its usefulnes within the warranty period. c) Exclusion The warranty for defects shall not apply to natural wear and tear or transport damages. Neither shall it apply to damages resulting from failure to observe the installation instructions or unprofessional installation. BEG is to be allowed the necessary time and opportunity to remedy the defect. BEG shall not assume liability for the consequence of improper modifications or repair work. This shall also apply to the supply of individual and replacement parts. BEG shall not assume liability for indirect, consequential and pecuniary loss. d) Period of limitation Should BEG nor recognize notification of defects made on time, the right to assert claims arising from the defects of the party entitled to the warranty shall become statutebarred in all cases 6 months following the date on which the notification of the defect was made on time. e) Return of the defect unit In the event of the warranty being availed of, the unit must be submitted to us through the specialist retailer together with the warranty card filled in and the sales receipt, as well as a short description of the defect. BEG Brück Electronic GmbH - Schlosserstr D Lindlar BEG (UK) Ltd - Abbey House, 450 Bath - Heathrow UB7 0EB Unit model: LUXOMAT PD4 Date of sale to the customer: Note: No follow up of the warranty claim without the warranty card and the purchase receipt. Stamp and signature of the dealer or the electrician: Adress of the sender: Name: Street: Postal code/city: Defects discouvered: 36 B.E.G.

User Manual 120/240/300 Outdoor Motion Detector

User Manual 120/240/300 Outdoor Motion Detector User Manual 120/240/300 Outdoor Motion Detector Swiss Garde 4000 Warning! - Any work on the main power supply must only be completed by trained specialists. - The product must be installed in accordance

More information

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR In the Master function, the remote control entries will be acknowledged as follows: acknowledged 3 x with the red LED In the Slave function, each detection is acknowledged 2 x with the green LED. NOTE:

More information

Detailed operating instructions

Detailed operating instructions MA00613903 Detailed operating instructions MD 360/8 Basic EB10430404 MD 360i/8 Basic EB10430428 MD 360/24 Basic EB10430848 MD 360i/24 Basic EB10430862 MD 360/8 Basic SMB EB10430497 MD 360i/8 Basic SMB

More information

LUXOMAT Application examples for electricians and planners

LUXOMAT Application examples for electricians and planners LUXOMAT Application examples for electricians and planners Plan with B.E.G. comfortably and certainly Along with a great number of useful practical tips, in this chapter you will also find many application

More information

Detailed operating instructions

Detailed operating instructions MA00744002 Detailed operating instructions MD-FLAT 360i/8 RW EP10427886 MD-FLAT 360i/8 SW EP10427893 MD-FLAT 360i/8 RB EP10428074 MD-FLAT 360i/8 SB EP10428081 MD-FLAT-E 360i/8 RW GST EP10427862 MD-FLAT-E

More information

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector 307021 3. Proper use EN Motion detector themova P360-100 UP WH 1030600 themova P360-100 UP GR 1030601 The motion detector is intended for interior. The motion detector is eclusively intended for the use

More information

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR 307079 EN Motion detector themova P360 KNX UP WH 1039600 themova P360 KNX UP GR 1039601 1. Product characteristics 4 2. Safety 5 3. Proper use 6 4. Function 6 5. Detection area 10 6. Installation 13 7.

More information

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6 307214 1103107701 EN Presence detector theronda S360-101 DE WH 2080565 theronda S360-101 DE GR 2080566 theronda S360-101 AP WH 2080555 theronda S360-101 AP GR 2080556 1. Product characteristics 4 2. Safety

More information

compact office 24V compact office 24V Lux

compact office 24V compact office 24V Lux Presence detector compact office 24V compact office 24V Lux Art. Nr. 201 4 000 Art. Nr. 201 4 001 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de

More information

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector EN Motion detector themova S360-101 DE WH 1030565 themova S360-101 DE GR 1030566 themova S360-101 AP WH 1030555 themova S360-101 AP GR 1030556 1. Product characteristics 307067 Passive infra-red motion

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 4 START-UP All parameter settings are carried out via the ETS (Engineering Tool Software). The magnet provided can be used to activate the programming status for the physical address on the PD-ATMO 360i/8

More information

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR GB Contents 1. GENERAL 1 1.1 KNX bus basics 1 1.2. Overview 1 1.3 Symbols 1 2. OCCUPANCY DETECTOR BASICS 2-3 2.1 Introduction 2 2.2 Motion detection with the B.E.G.

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

UP 258E11 OPTISENS OFFICE

UP 258E11 OPTISENS OFFICE Product and functional description The UP 258E11 is a presence/motion detector with integrated 2-point light control. The UP 258E11 device communicates via KNX/EIB with actuators or other KNX devices.

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

compact office 24V compact office 24V Lux

compact office 24V compact office 24V Lux Presence detector compact office 24V compact office 24V Lux Art. Nr. 201 4 000 Art. Nr. 201 4 001 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 21 Installation manual 40 Manual de

More information

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series Installation Instructions Contents 1.0 Product Range...3 2.0 Principle of Operation...3 3.0 Field of View...3 4.0 System Components

More information

B.E.G. LUXOMAT. Find the right detector.

B.E.G. LUXOMAT. Find the right detector. B.E.G. LUXOMAT Find the right detector www.beg-luxomat.com B.E.G. B.E.G. SMARTPHONE APP The new B.E.G. remote control app 92726 Rapid programming by smartphone The B.E.G. remote control app is the easiest

More information

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42 Presence detector ECO-IR 360C NT Art. Nr. 202 0 400 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de instrucciones 62 Istruzioni per l uso 82 Gebruikershandleiding

More information

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX.. Presence detector PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX.. D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 32 Operating Manual

More information

Product and Applications Description

Product and Applications Description Product and Applications Description The presence detector with a sensing range of 360 allows the automatic execution of control functions in the electrical system by detecting movements. For example,

More information

1. Basic safety information 3 2. Proper use 3

1. Basic safety information 3 2. Proper use 3 307146 03 EN Presence detector thepiccola P360-100 DE WH 2090200 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Device description 4 4. Installation and connection 4 Installing the presence

More information

FR-A180 FR-A360. Occupancy detector. Use

FR-A180 FR-A360. Occupancy detector. Use 5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable

More information

Operating instructions

Operating instructions MA00929301 09/2015 Operating instructions ED10429002 ESYLUX GmbH An der Strusbek 40 22926 Ahrensburg Germany info@esylux.com www.esylux.com 1 Table of contents 1 Using the manual 8 2 Safety instructions

More information

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual

More information

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER TOCR0 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER SAFETY PRECAUTIONS Be sure to switch off power source before installing. Make sure that the power wiring comes from circuit with an external 16A miniature

More information

Highlights. SMARTHOME product combinations. Starter Set 4 radiator control for saving energy wirelessly controlled 2013/1.

Highlights. SMARTHOME product combinations. Starter Set 4 radiator control for saving energy wirelessly controlled 2013/1. Highlights 2013/1 www.beg-luxomat.com SMARTHOME product combinations Motion and occupancy detectors Lights and photocells Starter Set 4 radiator control for saving energy wirelessly controlled V-Boxes

More information

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A.. Presence detector PräsenzLight 180.. PräsenzLight 360.. PräsenzLight 180-100A.. PräsenzLight 360-100A.. D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 26 Installation manual 50 Manual

More information

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features EBDHS-DD-LT30 Product Guide Ceiling PIR HS presence detector DALI / DSI, low temperature Overview The EBDHS-DD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

1. Basic safety information 3 2. Proper use 3

1. Basic safety information 3 2. Proper use 3 310481 01 EN Motion detectors theluxa P220 WH 1010605 theluxa P220 BK 1010606 theluxa P300 WH 1010610 theluxa P300 BK 1010611 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Description 4 4.

More information

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector EN Presence detector theprema S360-100 E UP WH 2070600 theprema S360-100 E UP GR 2070601 1. Product characteristics 307184 1103087901 Passive infrared presence detector for ceiling installation Square

More information

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector Product DELTA i-system DELTA profil titanium white 5WG1 258-2HB11 pearl grey 5WG1 255-2AB01 carbon metallic 5WG1 258-2HB21 titanium white 5WG1 255-2AB11 aluminum metallic 5WG1 258-2H1 anthracite 5WG1 255-2AB21

More information

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB Product DELTA profil DELTA ambiente DELTA style DELTA i-system Motion detector 5WG1 255-2AB01 pearl grey 5WG1 256-2AB01 arctic white 5WG1 255-2AB11 titanium white 5WG1 258-2HB11 titanium white 5WG1 255-2AB11

More information

PresenceLight 180 PresenceLight 360

PresenceLight 180 PresenceLight 360 Presence detector PresenceLight 180 PresenceLight 360 Art. Nr. 200 0 050 Art. Nr. 200 0 000 D F GB E I NL Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de instrucciones 62

More information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor. Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PPAD-C-HB-DALI-230V Product Guide Ceiling PIR HS presence detector DALI / DSI dimming Overview The PPAD-C-HB-DALI-230V PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

2. Safety. 4. Function

2. Safety. 4. Function EN Presence detector KNX AP WH 2089550 KNX AP GR 2089551 KNX FLAT DE WH 2089560 KNX FLAT DE GR 2089561 1. Product characteristics 307337 1103092301 Passive infrared presence detector for ceiling Circular

More information

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDSPIR-HB-AD High bay PIR presence detector 1-10V dimming Overview The EBDSPIR-HB-AD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector EN Motion detector KNX DE WH 1039560 KNX DE GR 1039561 KNX AP WH 1039550 KNX AP GR 1039551 307090 The device is maintenance-free. If the device is opened or penetrated with any object, the guarantee lapses.

More information

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MWS6-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS6-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual

More information

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2 II112918-SL Installation Guide VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2 TECHNICAL DATA Rated voltage: 220V-240V~ 50/60Hz Load: Load 1( /T1) for Lighting Incandescent: Max.

More information

KNX/EIB - Product database - Application description

KNX/EIB - Product database - Application description KNX/EIB - Product database - pplication description Theben HTS KNX/EIB Product Database V3.2 for Theben HTS presence detectors ECO-IR 360EIB-C ECO-IR 180EIB-C ECO-IR DUL-EIB compact office EIB compact

More information

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector EN Presence detector theprema P360-101 E UP WH 2070105 theprema P360-101 E UP GR 2070106 1. Product characteristics 307175 1103087101 Passive infrared presence detector for ceiling installation Square

More information

Description of the application programme for KNX occupancy detectors version 3.1

Description of the application programme for KNX occupancy detectors version 3.1 Contents 1. General...1 1.1 Basics for the KNX/EIB BUS...1 1.2 Application versions...1 1.2 Application versions Switchgear application Version 3.1: BEG_SWI_HKL_V3.1 Part numbers: 1.3 Symbols used...1

More information

Movement controller comfort, Flush-mounted (Up) xx, xx

Movement controller comfort, Flush-mounted (Up) xx, xx Order no.: 752615xx 752616xx The instabus movement controller comfort is designed for internal use and is pushed onto a flushmounted bus coupling unit (BCU). It reacts to heat movements triggered by persons,

More information

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual Observer 220 Art.-No.: W 220 WW Operationsmanual 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions Art.-No.: AS..1280-1.. Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description. EN Motion detectors theluxa P0 WH 0 theluxa P0 BK 0 theluxa P00 WH theluxa P00 BK. Basic safety information WARNING anger of death through electric shock or fire! ¾Installation should only be carried out

More information

B.E.G. Already heard of it? News

B.E.G.   Already heard of it? News B.E.G. Already heard of it? News 2014 Discover energy-savings potentials with OCCULOG* and convince your clients! How to save energy Knowing today about your energy-savings for tomorrow It is common knowledge

More information

IP65 High Bay Dual Sense Sensor

IP65 High Bay Dual Sense Sensor IP65 High Bay Dual Sense Sensor TM and, 1-10V Dimming with Remote Control Technical Data Input Characteristics Sensor Data Model No. Model No. Mains voltage 220-240VAC 50/60Hz Sensor principle High Frequency

More information

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features Product Guide MWS3A-PRM Ceiling microwave presence/absence detector Overview The MWS3A-PRM microwave presence detector provides automatic control of lighting loads with optional manual control. The MWS3A-PRM

More information

KNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX

KNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX 2CKA001473B8668 23.02.2017 KNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX Busch-Presence detector mini KNX 6131/20-xxx-500 Busch-Presence detector mini, premium, KNX 6131/21-xxx-500

More information

Presence detector Komfort attachment Installation Instructions

Presence detector Komfort attachment Installation Instructions Presence detector Standard attachment Order no.: 0304 0x Order no.: 0319 0x System information This unit is a product of the Instabus-EIB-System and corresponds to the EIBA Guidelines. Detailed technical

More information

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G. B.E.G. LUXOMAT net KNX intelligent building automation using sensors from B.E.G. Effective energy saving in buildings 2 KNX sensors from B.E.G. are specially developed for the creation of economical solutions

More information

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor

More information

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm). Flush Mount PIR Motion Sensor PIR 1-10V Dimming with Remote Control Mechanical Structure 70mm 64.7 4 56 68.1 73.3 Ø85 3 (1) Sensor inset (2) Lens pluggable Infrared receiver 1 Photocell LED indicator (3)

More information

EBMHS (standard & slim-line PSU)

EBMHS (standard & slim-line PSU) Product Guide EBMHS (standard & slim-line PSU) Miniature HS PIR Presence Detector (luminaire fitting) Overview The EBMHS series of miniature PIR (passive infrared) presence detectors provide automatic

More information

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features Product Guide MWS6-PRM Ceiling microwave presence/absence detector Overview The MWS6-PRM microwave presence detector provides automatic control of lighting loads with optional manual control. The MWS6-PRM

More information

IP65 High Bay Dual Sense Sensor

IP65 High Bay Dual Sense Sensor IP65 High Bay Dual Sense Sensor TM and, Daylight Harvest with Remote Control Technical Data Input Characteristics Sensor Data Model No. Model No. Mains voltage 220-240VAC 50/60Hz Sensor principle High

More information

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR 8. SPECIFICATION LOAD 6 Amps fluorescent and incandescent lighting. 3 Amps compact fluorescent lighting. 3 Amps low energy lighting. 3 Amps low voltage lighting (switch primary of transformer). Switch

More information

60W Multi PIR Bulkhead

60W Multi PIR Bulkhead 60W Multi PIR Bulkhead Model: MLB98 Black Installation & Operating Instructions 1. General information: The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon

More information

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS 2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS SLB2000 PIR LIGHT CONTROLLER - BLACK WEATHERPROOF IP44 PIR SWITCHING 2000w MAXIMUM MANUAL ON/OFF OVERRIDE TIME

More information

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring. Ø297mm Packing list in Ceiling Mount Lamp LEDS 96PCS Φ6 Wall plug 3x30 Screw Φ3 Sealing ring 4x12 Y type Stainless Screw Quantity 1X 4X 4X 3X 3X PRODUCT INFORMATION 98.5mm Ideal for energy saving this

More information

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK. VI64 Version:1.1 Issued 06/12/2007 INTRODUCTION Ventcroft s external sounder/strobes offer an unsurpassed range of models which provide for virtually any installation need. Most models feature a robust

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Analogue Dimming Microwave Presence/Absence Detector

Analogue Dimming Microwave Presence/Absence Detector Product Guide MWS3A-AD Analogue Dimming Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Fixing 3 4 Installation 3

More information

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use! Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de

More information

SERVICE MANUAL New Electronic Cold Platform 2005.

SERVICE MANUAL New Electronic Cold Platform 2005. SERVICE MANUAL New Electronic Cold Platform 2005. All the parts included in this document are the property of Indesit Company S.p.A. All rights reserved. This document and the information it contains are

More information

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor ILD Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) 2 DALI/DSI output channels

More information

Save energy. ARGUS presence detectors

Save energy. ARGUS presence detectors Save energy Ef cient energy use 2 Keeping energy costs down Increasing energy costs and growing awareness of the environment in modern buildings management now mean that more innovative solutions for efficient

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits uminaire-integrated modules ENOTEC modular system 110046819 Control CD I 110046818 Control CD CO1 110046814 ensor ED HF1 110046813 ensor ED HF2 110046816 ensor ED PIR Function description The new ENOTEC

More information

Direct Dim Microwave Presence/Absence Detector

Direct Dim Microwave Presence/Absence Detector Product Guide MWS3A-DD Direct Dim Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Fixing 3 4 Installation 3 5 Fixing

More information

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS DETECTOR TRANSMITTER Cat No. TLTX2000B INSTALLATION & OPERATING INSTRUCTIONS 1 Introduction The TLTX2000B Controller Transmitter is part of the Timeguard range of PIR products which communicate by radio

More information

B.E.G. PRESS KIT 2013

B.E.G. PRESS KIT 2013 B.E.G. PRESS KIT 2013 www.beg-luxomat.com Motion detectors Occupancy detectors Automatic lights Halogen and LED floodlights Energy saving floodlights Time switches Photo Electric switches Emergency and

More information

Ceiling Microwave presence/absence detector 12-24V AC/DC

Ceiling Microwave presence/absence detector 12-24V AC/DC MWS3A-PRM-LV Product Guide Ceiling Microwave presence/absence detector 12-24V AC/DC Overview The MWS3A-PRM-LV Microwave presence detector provides automatic control of low voltage loads including lighting

More information

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1 Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) DALI/DSI output channels with adjustable negative offset from channel to channel 1 Ambient light

More information

Remote alarm case VENTIremote alarm 10 m WM VENTIremote alarm 30 m WM Device description and instructions for use

Remote alarm case VENTIremote alarm 10 m WM VENTIremote alarm 30 m WM Device description and instructions for use VENTIremote alarm Remote alarm case VENTIremote alarm 10 m WM 27745 VENTIremote alarm 30 m WM 27755 Device description and instructions for use Overview VENTIremote alarm 5 Stand-by indicator 1 Battery

More information

Integrated PIR detectors

Integrated PIR detectors EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Detector switch - Dual Tech SCS

Detector switch - Dual Tech SCS 0 672 26 0 784 86 5 740 48 5 740 98 Page 1. Use...1 2. Technical characteristics....1 3. Dimensions....1 4. Connection...1 5. Installation...2 6. Operation...2 7. Settings...2 8. Configuration....3 9.

More information

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit Instruction Bulletin 63249-420-418A1 02/2014 Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit Commercial Grade with Ground SLSPWD1277C Retain for Future Use INTRODUCTION The Passive Infrared

More information

Sensero-868/915 AC, Sensero-868/915 AC Plus Nr , , ,

Sensero-868/915 AC, Sensero-868/915 AC Plus Nr , , , Sensero-868/915 AC, Sensero-868/915 AC Plus Nr. 28890.0001, 28900.0001, 28890.0901, 28900.0901 Installation instructions (translation) Safety instructions light sensor rain sensor light sensor The instructions

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

Movement-based energy control

Movement-based energy control 04 Movement-based energy control 94 International catalogue 2015 4.1 Microwave-based movement sensors 4.2 PIR-based movement sensors 4.2.1 Ceiling-mount 4.2.2 Wall-mount 4.3 Twilight switches 4.4 LED lights

More information

ARGUS movement detectors

ARGUS movement detectors ARGUS movement detectors Working principle Almost all movement detectors, including the ARGUS, function according to the principle of passive infrared technology. They measure and compare the infrared

More information

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components pure white Order-No. : 0317 02 colour aluminium Order-No. : 0317 04 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure

More information

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features Product Guide PPAD-C-230V Ceiling PIR presence/absence detector Overview The PPAD-C-230V passive infrared presence detector provides automatic control of lighting loads with optional manual control. The

More information

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller Model: MLSA360N Installation & Operating Instructions 360º Night Eye PIR Light Controller Motion Sensor Detection Perspective View 5 metre 1 Ceiling Mount Position 0º Sensor Tilt Up 3º 3º 5 metre Sensor

More information

360º Surface Mount Ceiling PIR Light Controller

360º Surface Mount Ceiling PIR Light Controller 360º Surface Mount Ceiling PIR Light Controller Model: PDRS1500 Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference

More information

SENSA MRE DDM MR

SENSA MRE DDM MR 96239831 SENSA MRE DDM MR Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring and fixing 3 4 Programming 6 5 Wiring diagrams 8 6 Detection pattern diagrams

More information

High Frequency Sensor

High Frequency Sensor Model: HF1 Installation & Operating Instructions High Frequency Sensor 1. Specifications: 1. Power: AC 220 ~ 240V 50MHz. 2. Sensor Technology: 5.8GHz High Frequency. 3. Switching capacity: 1000W Incandescent

More information

BiSens SWR-230V. Installation instructions (translation) Safety instructions. Safety instructions for radio operation

BiSens SWR-230V. Installation instructions (translation) Safety instructions. Safety instructions for radio operation BiSens SWR-230V Installation instructions (translation) Safety instructions light sensor rain sensor light sensor The instructions must be observed in order to ensure the product can be operated smoothly

More information

Connections, displays and operating elements E F. 20s 3min

Connections, displays and operating elements E F. 20s 3min 40s 80s 20s 3min 1s 8min KNX FUGA Movement detector 180Art.-Nr. 507D6350, 507D5350, 507D8350 Merten2005V6326-541-0009/09 KNX FUGA Movement detector 180 Operating instructions Connections, displays and

More information

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

1 Safety instructions. 2 Device components. Presence detector. Operating instructions Presence detector Standard Art. No. 3361 WW Presence detector Standard Art. No. 3361 AL Presende detector Universal Art. No. 3361-1 WW Presende detector Universal Art. No. 3361-1 AL Operating instructions

More information

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L C-Bus PIR Occupancy Sensor Installation Instructions 5751L Contents 1.0 Description 3 2.0 Important Notes 3 3.0 Installation 3 4.0 C-Bus Network Connection 6 5.0 Programming and Setup 7 6.0 Troubleshooting

More information

LED Sensor Floodlight AZPOSE XL-S

LED Sensor Floodlight AZPOSE XL-S LED Sensor Floodlight AZPOSE XL-S XL-25S-765/830/840 XL-10S-765/830/840 Installation Guide Contents Product Information...p.1 Specifications...p.1 Specifications summary...p.2 Detection Range...p.2 Outline

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-A-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-A-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500 0073-1-7613 Rev. 01 06.2011 KNX Technical Reference Manual Busch Präsenz tech 6131/10-500 6131/11-500 KNX Technical Reference Manual Busch Präsenz tech 1 Safety instructions Work on the 230 V power supply

More information

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components pure white Order-No. : 2270 02 colour aluminium Order-No. : 2270 04 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure

More information