Additional deviations may possibly be found if a complete type test is carried out on the product.

Size: px
Start display at page:

Download "Additional deviations may possibly be found if a complete type test is carried out on the product."

Transcription

1 Diary No. 13EV4171 Reference No MARKET SURVEILLANCE TEST REPORT - LVD The tests cover parts of the requirements for AC adapter stated in the standard SS-EN 60950: A11 + A1 + A12 and EN References to clauses are given to SS- EN 60950: A11 + A1 + A12, unless stated otherwise. Additional deviations may possibly be found if a complete type test is carried out on the product. Deviations are graded according to three levels with corresponding codes. The first level, serious criticism, corresponds to code 3, criticism to code 2 and remark, to code 1. DESCRIPTION OF TEST SAMPLE Type of product: Replacemant AC Adapter Manufacturer: - Retailer: - Type designation: A1184 Rating: AC INPUT: V, 1.5A, 50/60Hz DC OUTPUT: 16.5V, 3.65A Serial number: - EAN-code: - Certification marks: - CE marked: Yes Others: - RESULT The table below shows the number of criticisms according to the various codes. Code: Number: Serious criticism (3): - Criticism (2): 2 Remark (1): 1 TEST AND INSPECTIONS PERFORMED Clause Power rating Clause 2.10 Clearances, creepage distances and distances through insulation (excluding internal distances in components) Clause 4.2 Mechanical strength Clause 4.6 Openings in enclosure Clause 5.1 Touch current Clause 5.2 Electric strength test 1(2)

2 Diary No. 13EV4171 Reference No LIST OF DEVIATIONS 1. Manufacturer s name or trad-mark is missing (Cl. 1.7 acc. to standard EN 60950: A11 + A1 + A12) Code: (2) 2. Electric strength test between primary and secondary output, required 3000V, break down at 2500V. Electric strength test on transformer between primary and secondary, required 3000V, break down at 2600V. (Cl. 5.2 acc. to standard EN 60950: A11 + A1 + A12) Code: (1) 3. Clearances and creepage distances in transformer, required clearance 4.0mm and creepage 4.8mm. Actual measured distance 2.5mm. (Cl and 4 acc. to standard EN 60950: A11 + A1 + A12) Code: (2) 2(2)

3 NOTIFICATION UNDER ARTICLE 9 OF THE LOW VOLTAGE DIRECTIVE Notification no. SE Name of the notifying authority a) Member State: Sweden b) Full name and address, telephone and fax numbers, of the department and of the competent official supplying the information: Swedish National Electrical Safety Board P.O. Box 4 S Kristinehamn; Sweden Tel: Fax: info@elsakerhetsverket.se 2. Identification of the equipment a) Name and description: Replacemant AC Adapter b) Brand and type: Unknown brand, typedesignation is A1184 c) Name and address of the owner of the brand: Unknown d) Name and address of the manufacturer or importer: Man: Imp: Riset Adapterexperten AB Vasängsvägen Halmstad, Sweden e) Other countries in which the equipment is placed on the market: Unknown f) Electrical specifications (voltage, wattage, class of protection against electric shock, IP classification): AC INPUT: V, 1.5A, 50/60Hz DC OUTPUT: 16.5V, 3.65A

4 3. Proof of conformity a) CE marking: yes no b) Other directive(s) covered by CE marking: yes which one(s)? EMC no c) Other markings: d) Written declaration of conformity: available requested not requested acceptable not acceptable not available g) Technical documentation: available requested not requested acceptable not acceptable not available h) Report drawn up by a notified body: available requested not requested Name of the notified body: Reference number of the report: not available

5 4. Details of the measures taken a) manufacturer importer into the EEA Type of measure: importer to Sweden removal from circulation prohibition of the placing of the equipment on the market general measures making the placing of the equipment on the market subject to specific conditions other b) manufacturer Importer into the EEA Importer to Sweden Date: Reference: Method of notification: 13EV4171 By letter 5. Reasons for the measures taken Non-conformity with Article 2 of the Low Voltage Directive resulting from a shortcoming in the applicable standard(s) Standard(s) reference: Non-conformity with Article 2 of the Low Voltage Directive resulting from a faulty application of the applicable standard(s) Standard(s) reference: EN Where no standard applied, non compliance with the rules of good engineering practice as referred to in Article 2 of the Low Voltage Directive

6 6. Brief description of faults, nature of hazards and/or shortcomings in standards observed Manufacturer s name or trad-mark is missing. Electric strength test between primary and secondary output, required 3000V, break down at 2500V. Electric strength test on transformer between primary and secondary, required 3000V, break down at 2600V. Clearances and creepage distances in transformer, required clearance 4.0mm and creepage 4.8mm. Actual measured distance 2.5mm. 7. Additional information annexed copy of test reports 2 (pages) photographs 1 (pages) copy of declaration of conformity distribution chain others Date: Karl-Hugo Hult Head of Department Martin Gustafsson

LOW VOLTAGE DIRECTIVE 2006/95/EC

LOW VOLTAGE DIRECTIVE 2006/95/EC LOW VOLTAGE DIRECTIVE 2006/95/EC SAFEGUARD NOTIFICATION UNDER ARTICLE 9 1 INFORMAL EXCHANGE OF INFORMATION * 1. Name of the tifying a. Member State / other SPAIN b. Full name and address, telephone and

More information

LOW VOLTAGE DIRECTIVE 2006/95/EC

LOW VOLTAGE DIRECTIVE 2006/95/EC LOW VOLTAGE DIRECTIVE 2006/95/EC SAFEGUARD NOTIFICATION UNDER ARTICLE 9 1 INFORMAL EXCHANGE OF INFORMATION * 1. Name of the tifying a. Member State / other SPAIN b. Full name and address, telephone and

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62040-1-2 First edition 2002-08 Uninterruptible power systems (UPS) Part 1-2: General and safety requirements for UPS used in restricted access locations Alimentations sans interruption

More information

CE marking & your legal obligations

CE marking & your legal obligations CE marking & your legal obligations This presentation is intended to provide a practical approach guide to what you need to know about the CE marking requirements for electrical and electronic equipment

More information

CE Marking and Technical Standardisation

CE Marking and Technical Standardisation EDITION 3.0 CE Marking and A G A M B I C A T E C H N I C A L G U I D E Technical Standardisation Guidelines for application to Electrical Power Drive Systems CE Marking and Technical Standardisation Guidelines

More information

ENGLISH USER S MANUAL PRE SOAKER 3600

ENGLISH USER S MANUAL PRE SOAKER 3600 ENGLISH http://www.rangeservant.com USER S MANUAL PRE SOAKER 3600 CONTENTS 1 General 4 1.1 Preface 4 1.2 EC Declaration of Conformity 5 1.3 Description 6 1.3.1 Pre Soaker 6 1.3.2 Ball Management System

More information

AS/NZS IEC :2013

AS/NZS IEC :2013 AS/NZS IEC 61347.2.13:2013 (IEC 61347-2-13, Ed.1.0 2006, MOD) Australian/New Zealand Standard Lamp controlgear Part 2.13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

Installer: (Name, address, telephone)

Installer: (Name, address, telephone) Installer: (Name, address, telephone) UNAC GUIDE No. 5 FOR THE MOTORISATION OF FOLDING DOORS IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1, EN 12453,

More information

Installer: (Name, address, telephone)

Installer: (Name, address, telephone) Installer: (Name, address, telephone) UNAC GUIDE No. 2 FOR THE MOTORISATION OF HINGED GATES IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1, EN 12453,

More information

Datasheet - MZM 100 ST2-1P2PWREM-A

Datasheet - MZM 100 ST2-1P2PWREM-A 30.05.2015-14:45:08h Datasheet - MZM 100 ST2-1P2PWREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics... 14 Ex SOLENOID / ALARM DRIVER PRepower 5203B Table of contents Warnings... 16 Safety instructions... 17 Declaration of Conformity... 19 How to dismantle SYSTEM 5000... 20 Application... 21 Technical characteristics...

More information

Datasheet - MZM 100 ST-SD2PREM-A

Datasheet - MZM 100 ST-SD2PREM-A 19.03.2014-10:31:42h Datasheet - MZM 100 ST-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS SPECIFICATIONS FOR LV DIGITAL PANEL METERS This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE

More information

Datasheet - MZM 100 B ST2-SD2PREM-A

Datasheet - MZM 100 B ST2-SD2PREM-A 30.05.2015-14:46:12h Datasheet - MZM 100 B ST2-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry 1. Must a construction product bear the CE marking after 30/06/2013? After 30/06/2013, in order to sell a construction product in the European Union (EU) the manufacturer has the obligation to issue a

More information

Installer: (Name, address, telephone number)

Installer: (Name, address, telephone number) Installer: (Name, address, telephone number) UNAC GUIDE No. 9 FOR THE INSTALLATION OF MOTORISED VERTICAL UPWARD SLIDING GATES IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF

More information

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland Electrical Safety Act (1135/2016) By decision of Parliament, the following is enacted:

More information

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION INTERNATIONAL ELECTROTECHNICAL COMMISSION GUIDE 111 Second edition 2004-07 Electrical high-voltage equipment in high-voltage substations Common recommendations for product standards IEC 2004 Copyright

More information

Living with the Construction Products Directive - The Role of the Notified Bodies

Living with the Construction Products Directive - The Role of the Notified Bodies Living with the Construction Products Directive - The Role of the Notified Bodies Francky Callewaert DG Enterprise The core of the CE marking Is obligatory for every construction product placed on the

More information

CE marking & your legal obligations

CE marking & your legal obligations CE marking & your legal obligations This presentation is intended to provide a practical approach guide to what you need to know about the CE marking requirements for electrical and electronic equipment

More information

Installer: (Name, address, telephone number)

Installer: (Name, address, telephone number) Installer: (Name, address, telephone number) UNAC GUIDE No. 8 FOR THE INSTALLATION OF MOTORISED BARRIERS IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1,

More information

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - TF N 530 Rev.2 2012-04-13 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 Drafting

More information

INSTRUCTION MANUAL (ATEX)

INSTRUCTION MANUAL (ATEX) INSTRUCTION MANUAL (ATEX) ISmA1M Minialarm Intrinsically Safe Round ISmA1M Volume Control Tone Generator S3 Tone Selection Switches Fig 1 Simplified block diagram The ISmA1M sounder is CE marked for compliance

More information

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 165 Report No.: E309264-D1028-1/A0/C0-UL Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential performance

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62052-11 First edition 2003-02 Electricity metering equipment (AC) General requirements, tests and test conditions Part 11: Metering equipment This English-language version is

More information

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4 GB OPERATING MANUAL ORWAK 3400 March 2005 PUBL. NO 4869057-00 Edition 4 English TABLE OF CONTENTS Safety... 82 Operating instructions... 93 Technical specifications. 104 Dimensional drawing... 104 Transport...

More information

Kitchen Appliance Lift INSTRUCTION MANUAL

Kitchen Appliance Lift INSTRUCTION MANUAL Kitchen Appliance Lift INSTRUCTION MANUAL Contents Section: Headline: Page: 1. Introduction...4 2. Declaration of Conformity...4 3. Intended use - Technical data...4 Installation instructions: 4.1 Mechanical

More information

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR)

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR) November 2013 Last updated: June 2015 Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR) Frequently Asked Questions Part IV Preliminary remarks

More information

The New EMC Directive 2004/108/EC

The New EMC Directive 2004/108/EC The New EMC Directive 2004/108/EC In the process of this review I have tried to spell out in words what is often referred to as a section number while also keeping to location information as used in the

More information

Alarm Switchgear AS1-M

Alarm Switchgear AS1-M Installation, Operating and Maintenance Instructions 1/7 Installation, Operating, and Maintenance Manual for Alarm Switchgear AS1-M These installation, operating and maintenance manual must be handed to

More information

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

AS/NZS :2003 Luminaires - Part 1: General requirements and tests Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 60598.1:2003 Luminaires - Part 1: General requirements and tests Table of Contents View on Information Provider

More information

Chain saws (electric mains powered and battery powered)

Chain saws (electric mains powered and battery powered) Compliance Guide Edition 09/2016 Chain saws (electric mains powered and battery powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206 68

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MNUL (TEX / IECEx) ExG21D Flameproof Xenon eacon For use in Flammable Gas and Dust tmospheres 1) Introduction The ExG21D is a flameproof beacon certified to meet the requirements of the TEX

More information

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a Korea Communications Commission Notification 2011-37 In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a guideline for all broadcasting and telecommunications equipment

More information

Edition 6, From serial no Publ. no Orwak 5030-CE. Operating manual

Edition 6, From serial no Publ. no Orwak 5030-CE. Operating manual Edition 6, From serial no. 78087 Publ. no 4869700-00 2008-01 Orwak 5030-CE Operating manual English CONTENTS Safety...8 2 Operating instructions...9 3 Technical specifications...10 4 Dimensional sketch...10

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60598-2-3 Third edition 2002-12 Luminaires Part 2-3: Particular requirements This English-language version is derived from the original bilingual publication by leaving out all

More information

TECHNICAL NOTICE GH/GHO/GAE V

TECHNICAL NOTICE GH/GHO/GAE V TECHNICAL NOTICE GH/GHO/GAE V1.0-02.14 INDUSTRIAL COOLING UNITS Identification Marksa SA Industrial cooling 39, avenue du Technicum CH-2400 Le Locle Version Date Modifications 1.0 14.02.14 First edition

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...: Test Report issued under the responsibility of: TEST REORT IEC 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) art 1: General

More information

Statistics on RAPEX notifications (November 2017)

Statistics on RAPEX notifications (November 2017) EUROPEAN COMMISSION JUSTICE AND CONSUMERS DIRECTORATE-GENERAL Consumer Affairs Product safety and Rapid Alert System Brussels, 4 December 2017 Statistics on RAPEX notifications (November 2017) In accordance

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60939-2 Second edition 2005-02 Passive filter units for electromagnetic interference suppression Part 2: Sectional specification Passive filter units for which safety tests are

More information

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1 Technical Sheet Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1 Application The Brink Renovent Excellent is a heat recovery ventilation unit with an efficiency of 95%, a

More information

Installer: (Name, address, telephone)

Installer: (Name, address, telephone) Installer: (Name, address, telephone) UNAC GUIDE No. 4 FOR THE MOTORISATION OF SECTIONAL GARAGE DOORS IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1,

More information

Declaration of Conformity Declaration of Performance Notes

Declaration of Conformity Declaration of Performance Notes What difference is there in the information to be included in the Declaration of Performance under the CPR (as updated by Delegated Act (EU) No. 574/2014) from that currently provided in the Declaration

More information

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks TEST REORT SUMMARY EN 50438 Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks Report reference number... : 12TH0525-EN50438_SUM_0 Date of issue......:

More information

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY ("Official Gazette of RS, issue No. 13/2010) I INTRODUCTION Scope Article 1 This Rulebook stipulates the essential requirements that shall be met with regard to

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Integrated electronic maximum-minimum thermometer, with factory programmed alarms, for vaccine refrigerators

More information

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group Pressure D. EVALUATION ASSESSMENT PROCEDURES Guideline D-01 Guideline related to: Annex III, module G Is design approval by a notified body required under module G? Module G does not explicitly require formal design

More information

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017 Chapter I o Scope and definitions Article 1 Subject matter and scope 13 Article 2 Definitions 15 Article 3 Amendment of certain definitions 20 Article 4 Regulatory status of products 20 Chapter II o Making

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Product Test Centre 15 Progress Road Eastwood Leigh-on-Sea Essex SS9 5JA Contact: Mr S Bailey Tel: +44 (0)1702 425738 E-Mail: stuart.bailey@honeywell.com

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60730-2-13 Edition 3.0 2017-10 Automatic electrical controls INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 97.120 ISBN 978-2-8322-4900-0 Warning! Make sure that you obtained

More information

Stationary and Portable Spas Important Safety Information

Stationary and Portable Spas Important Safety Information Stationary and Portable Spas Important Safety Information Impression of an example of such a product Following a number of complaints received by European Market Surveillance Authorities and resulting

More information

EU-TYPE EXAMINATION CERTIFICATE

EU-TYPE EXAMINATION CERTIFICATE 0402-MID-385402 Water meter Vesiverto V-15M Issued to: Address: Vercon Oy Hopunkatu 11, FI38200, SASTAMALA, Finland In respect of (type of instrument) Water meter for cold (T30) and hot water (T30/90).

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExTS110D Flameproof Sontel 1) Introduction The BExTS110D is a flameproof Sontel telephone sounder which is certified to the meet the requirements of the ATEX directive

More information

Council Directive 93/68/EEC of 22 July 1993 amending Directives

Council Directive 93/68/EEC of 22 July 1993 amending Directives Council Directive 93/68/EEC of 22 July 1993 amending Directives 87/404/EEC (simple pressure vessels), 88/378/EEC (safety of toys), 89/106/EEC (construction products), 89/336/EEC (electromagnetic compatibility),

More information

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Circuit Breakers JANUARY The electronic pdf version of this document found through   is the officially binding version STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for EU recognised organisation Mutual Recognition (MR) No. MR-E001 Circuit Breakers JANUARY 2013 The electronic pdf version

More information

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PHOTOELECTRIC CONTROL UNITS (PECUs) REFERENCE REV DATE: JUNE 2017 PAGE: 1 OF 16 REVISION DATE: Table of Contents FOREWORD... 3 INTRODUCTION... 4 1 SCOPE... 4 2 NORMATIVE REFERENCES...

More information

Installation / Monitoring Technique

Installation / Monitoring Technique Installation / Monitoring Technique INFOMSTER Common larm System, us Connection New- / First- /Common Signal nnunciator RP 5994, RP 5995 Replacements for: N 5969, N 5970, N 597 055005 Circuit Diagrams

More information

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE Page 1 of 4 CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE DoP Number: AS3002 AS3012 AS3052 1. Unique identification code of the product-type: AS3002 SIZE 1-6 OVERHEAD DOOR CLOSER SE

More information

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276 200662_2 Page 1 User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276 These instructions should be read carefully and retained for future reference. Important Notes These

More information

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL) Edition 8 From serial no. 106000- Publ. no 4869701-00 OM 5030NHD; 2012-02 Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL) English CONTENTS Safety...8 2 Operating instructions...9 3 Technical specifications...10

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance Test Report issued under the responsibility of: SGS- CSTC TEST REORT Safety of household and similar electrical appliances art 2: articular requirements for massage appliance Report Reference No....: GZES100800181503

More information

Consumer Products Services Germany GmbH Türkheim Germany

Consumer Products Services Germany GmbH Türkheim Germany TEST REORT SUMMARY EN 50438 Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks Report reference number... : 11TH0290-EN50438_SUM_2 Date of issue......:

More information

Audible warning devices for external alarm

Audible warning devices for external alarm VdS SCHADENVERHÜTUNG VdS Publisher: Gesamtverband der Deutschen Versicherungswirtschaft e.v. (GDV) Büro Schadenverhütung Publishing house: VdS Schadenverhütung Rules for Intruder Alarm Systems Audible

More information

Motorised swing doors User manual (translation of the original instructions) IP2225EN

Motorised swing doors User manual (translation of the original instructions)   IP2225EN Motorised swing doors User manual (translation of the original instructions) www.ditecentrematic.com IP2225EN Contents Description Page 1. General precautions for safe use 17 2. Responsibility for the

More information

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements ExTR Reference Number...: ExTR Free Reference Number...: 223531 Compiled by + signature (ExTL)...: Reviewed by + signature (ExTL)...: NO/NEM/ExTR12.0018/00 Stig André Norheim Arne Hortman Date of issue...:

More information

The New EMC Directive 2004/108/EC

The New EMC Directive 2004/108/EC The New EMC Directive 2004/108/EC In the process of the review I have tried to spell out in words what is often referred to as a section number. This helps reduce the need to flip pages as one reads this.

More information

ERTIFICATE. No. P This Nemko Certificate replaces the Certificate issued 27 March 2003 due to an error in the Factory listing.

ERTIFICATE. No. P This Nemko Certificate replaces the Certificate issued 27 March 2003 due to an error in the Factory listing. I:.~:D C ERTIFICATE Page 1 of 1 No. P031 00471 and also certificate and with, and for acceptance This Nemko Certificate replaces the Certificate issued 27 March 2003 due to an error in the Factory listing.

More information

Latch key safety limit switches Technical data

Latch key safety limit switches Technical data Latch key safety Safety General Data Standards IE 6047-1, IE 6047-5-1, EN 6047-1, EN 6047-5-1, UL 508, and SA 22-2 No. 14 ertifications - Approvals UL and SA Air temperature near the device during operation

More information

New Legal Framework Carlo Casati

New Legal Framework Carlo Casati New Legal Framework Carlo Casati Milan, 1 April 2016 Summary New Legislative Framework Market Surveillance Conformity Assessment CE Marking 2 06.11.2013 NOTIFIED BODY TRAINING 01 New Legislative Framework

More information

Test report. ifesesws^ Date: Number: T /17 Project file: C Pages: Product: Fixed general purpose LED luminaire

Test report. ifesesws^ Date: Number: T /17 Project file: C Pages: Product: Fixed general purpose LED luminaire Sl/Q ifesesws^ SLOVENSKA AKREDITACIJA SIST EN ISO/ 1EC 17025 L-009 Test report Number: roduct: roject file: Fixed general purpose LED luminaire Date: ages: C20170767 2017-04-26 12 Type reference: LA-FL/G-xxW-xxxxK-Rxxx/xxx-(D10kGy)

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60335-2-74 Second edition 2002-10 Household and similar electrical appliances Safety Part 2-74: Particular requirements for portable immersion heaters Appareils électrodomestiques

More information

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR TF N 635 Regulation 574_2014: Annex III CPR and Regulation 568_2014: Annex V CPR 30-05-2014 28.5.2014 L 159/41 REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 574/2014 of 21 February 2014 amending

More information

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS The ATEX Directive consists of two EU Directives, ATEX Directive 2014/34/EU and ATEX Directive 99/92/EC. ATEX Directive 2014/34/EU embodies the European minimum

More information

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE Flooring Declaration of Performance Edition 01.07.2013 Identification no. Version no. 01 EN 1504-2: 2004 08 0921 EN 13813: 2002 DECLARATION OF PERFORMANCE Declaration of performance 1. Product Type Unique

More information

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE Installation instructions For the heating engineer Installation instructions timeswitch VTS 160 GB, IE Table of contents Table of contents 1 Notes on the installation instructions...4 1.1 Observing other

More information

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY DECLARATION OF PERFORMANCE in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) 1. Unique identification code of the product type: ULTRA PROFLEX SP+ES GREY

More information

INTERNATIONAL STANDARD NORME INTERNATIONALE

INTERNATIONAL STANDARD NORME INTERNATIONALE IEC 62031 INTERNATIONAL STANDARD NORME INTERNATIONALE Edition 1.0 2008-01 2 62031 IEC:2008 CONTENTS FOREWORD...3 INTRODUCTION...5 1 Scope...6 2 Normative references...6 3 Terms and definitions...7 4 General

More information

Declaration of Performance

Declaration of Performance EN 1504-2:2004 09 0866 EN 13813 EN 1504-2:2004 DECLARATION OF PERFORMANCE 264 1. Product Type: Unique identification code of the product-type: 2. Type batch or serial number or any other element allowing

More information

CE marking of fire-resistant doors the right way!

CE marking of fire-resistant doors the right way! Page 1 of 5 ift Rosenheim CE marking of fire-resistant doors the right way! Surveillance and certification of fire safety products 1 Introduction The product standard for doors, gates and windows with

More information

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L MAJIK OWNERS MANUAL i MAINS PLUGS This appliance is supplied with a non-rewireable mains plug for the intended country. Replacement mains leads can be obtained from your Linn retailer. Should you need

More information

a guide to the interpretation of

a guide to the interpretation of a guide to the interpretation of EN50136-1-1 & EN50136-2-1 for alarm transmission systems & equipment June 2007 For other information please contact: British Security Industry Association t: 0845 389 3889

More information

COMMISSION DELEGATED REGULATION (EU)

COMMISSION DELEGATED REGULATION (EU) 28.5.2014 L 159/41 REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 574/2014 of 21 February 2014 amending Annex III to Regulation (EU) No 305/2011 of the European Parliament and of the Council on the

More information

LOVAG TEST INSTRUCTION IEC/EN

LOVAG TEST INSTRUCTION IEC/EN LOVAG TEST INSTRUCTION IEC/EN 60947-5-5 CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS- ELECTRICAL EMERGENCY STOP DEVICE WITH MECHANICAL LATCHING FUNCTION This test instruction is based on the following

More information

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV

More information

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to BS EN 16034: 2014 Permission to reproduce extracts from BS EN 16034 : 2014 is granted by BSI. DHF BEST PRACTICE

More information

DIRECTIVES. DIRECTIVE 2009/142/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 relating to appliances burning gaseous fuels

DIRECTIVES. DIRECTIVE 2009/142/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 relating to appliances burning gaseous fuels L 330/10 Official Journal of the European Union 16.12.2009 DIRECTIVES DIRECTIVE 2009/142/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 relating to appliances burning gaseous fuels

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60364-5-51 Fifth edition 2005-04 Electrical installations of buildings Part 5-51: Selection and erection of electrical equipment Common rules This English-language version is

More information

Electromagnetic Locking Devices Performance Requirements

Electromagnetic Locking Devices Performance Requirements Technical Specification Electromagnetic Locking Devices Performance Requirements DHF TS 010:2016 Technical specification produced by dhf www.dhfonline.org.uk Contents Foreword 1. Scope 2 ANNEX A Bodies

More information

Electrical Equipment (implementing the Low Voltage Directive)

Electrical Equipment (implementing the Low Voltage Directive) PRODUCT STANDARDS Electrical Equipment (implementing the Low Voltage Directive) GUIDANCE NOTES ON THE UK ELECTRICAL EQUIPMENT (SAFETY) REGULATIONS 1994 (S.I. 1994/3260) JULY 2004 URN 04/1106 Contents

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 60601-2-44 INTERNATIONAL STANDARD Edition 2.1 2002-11 Medical electrical equipment Part 2-44: Particular requirements for the safety of X-ray equipment for computed tomography INTERNATIONAL ELECTROTECHNICAL

More information

Gas Appliances Directive - Advisory Committee. Comité Consultatif de la Directive Appareils a Gaz

Gas Appliances Directive - Advisory Committee. Comité Consultatif de la Directive Appareils a Gaz Document GAD-AC N 519 E v2 Date 2016-11 23 Gas Appliances Directive - Advisory Committee Comité Consultatif de la Directive Appareils a Gaz FOR INFORMATION CONCERNING: Questions and Answers approved by

More information

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE Flooring Declaration of Performance Edition 01.07.2013 Identification no. Version no. 01 EN 1504-2: 2004 13 0921 EN 13813: 2002 DECLARATION OF PERFORMANCE Declaration of performance 1. Product Type Unique

More information

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60076-11 First edition 2004-05 Power transformers Part 11: Dry-type transformers This English-language version is derived from the original bilingual publication by leaving out

More information

Operating instructions

Operating instructions Operating instructions Capriz 2 24c 28c GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information... 4 2 Notes on the documentation...

More information

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE Flooring Declaration of Performance Edition 01.07.2013 Identification no. Version no. 01 EN 1504-2: 2004 08 0921 EN 13813: 2002 DECLARATION OF PERFORMANCE Declaration of performance 1. Product Type Unique

More information

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL) Edition 8, From serial no. 106000- Publ. no 4869699-00 OM 5030, 2012-02 Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL) English CONTENTS Safety...8 2 Operating instructions...9 3 Technical specifications...10

More information