Ç O K E S E N E L E K T R O N İ K LTD.

Size: px
Start display at page:

Download "Ç O K E S E N E L E K T R O N İ K LTD."

Transcription

1 Ç O K E S E N E L E K T R O N İ K LTD. Electricity - Security System Experiment sets Electrical Transmission Lines Trainer Set The Experiment Set is designed to perform sample applications related to energy distribution. It has been processed with CNC so that the Text and Symbols located on the Experiment Modules enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Module are designed to be indelible and non-scratchable.

2 Transmission Line Set 1 The set has 120 km and 150 km length, 70 kv and 90 kv voltage value and has a model capable of modeling a line with current values of 80A and 120A. The module voltage is in the range of V and the current value corresponds to about 5 ampere. In order to perform the necessary experiments with this sub-set, the following elements are given with the module. Three phase adjustable power supply according to the model: Input voltage 3x400 V output voltage can be adjusted between 3x0-450 V and the current value is 7A. Three-phase power supply suitable for the module: Input voltage each Phase 220V output voltage is 3 stages and the power rating is 2kVA (2 pieces). Three Phase Resistive Load: Compatible with the module (1 unit). Three Phase Capacitive Load: Modular (1 unit). Three Phase I inductive load: Compatible with the module (1 unit). Three Phase Energy Analyzer: Modular compatible. The microprocessor is controlled and can measure at least current, voltage and power (1 unit). Power Factor Meter: Compatible with the module (1 unit). Test Cables: Modular compatible. Load switches and Emergency stop modules: Module compatible Experimental Panel and Experiment Stand: Modular Experiment Manuals

3 Transmission Line Set 2 Set has 30 km and 50 km length, 35 kv and 45 kv voltage value, 300A and 400A current value has a model capable model. The module voltage corresponds to V and the current value corresponds to about 10 Ampere. In order to perform the necessary experiments with this sub-set, the following elements are given with the module: Modular three phase adjustable power supply: Input voltage 3x400 V output voltage 3x0-450 V Adjustable and current rating 7A (1 piece). Three phase power supply suitable for the module: Input voltage each Phase 220 V output voltage is 3-stage and power rating 2kVA (2 pieces). Three Phase Resistive Load: Compatible with the module (1 unit). Three Phase Capacitive Load: Modular (1 unit). Three Phase I inductive load: Compatible with the module (1 unit). Three Phase Energy Analyzer: Modular compatible. The microprocessor is controlled and can measure current, voltage and power (1 unit). Power Factor Meter: Compatible with the module (1 unit). Test cables: Modular Load Switches and Emergency Stop Modules: Modular Experimental Panel and Experiment Stand: Modular Transmission Line Set 3 The set has a model capable of modeling a line with current values of 700A and 900A with 120kV and 160kV voltage value, 90km and maximum 110km length. The module voltage

4 corresponds to V and the current value corresponds to about 10 Ampere. In order to perform the necessary experiments with this sub-set, the following elements are given with the module: Three phase adjustable power supply according to the model: Input voltage 3x400 V output voltage can be set between 3x0-450 V and current value is 7A (1 piece). Three phase power supply suitable for the module: Input voltage each phase 220 V output voltage 3 stages and power value 2kVA (2 pieces). Three Phase Resistive Load: Compatible with the module (1 unit). Three Phase Capacitive Load: Modular (1 unit). Three Phase Inductive Load: Modular (1). Three Phase Energy Analyzer: Microprocessor compatible with the module and can measure current, voltage and power (1 unit). Power Factor Meter: Compatible with the module (1 unit). Test Cables: Modular Load Switches and Emergency Stop Modules: Modular Experimental Panel and Experiment Stand: Modular In addition to the Transmission Line Test Sets, the following modules and / or devices are supplied: A Transmission Line Module (1 unit) with a length of 90 km and a length of 110 km, with a voltage value of 200 kv and 250 kv, capable of modeling a line with a power rating of 100 MVA and 120 MVA. A Transmission Line Module (1 unit) with 4 km and 6 km length, with a 10 kv and 12 kv voltage value, capable of modeling a line with 4 MVA and 6 MVA power ratings. Peterson bobbin module: In accordance with the above test sets (1 piece).

5 COKESEN - ES08 Modular Type Electrical Installations and Security Systems Trainers Illustration: Double sided, production according to technical specifications. Single sided model can be ordered. Modular Type Electrical Installation and Security Systems Experiment Set consists of 10 separate Experimental Groups. These: AC-DC Energy Laboratory Basic Installation Set Addressable Fire Detection Set Wired Thief Detection Kit

6 Wireless Burglar Detection Kit Building (Home) Security Kit Intercom System Application Kit Video Intercom System Conventional Fire Detection Set Card Door Transition Kit TECHNICAL SPECIFICATIONS: AC-DC Energy Quality Laboratory Panel Power and Supply Unit, Council Experiment Set Panel Laminate (Light Gray) metal parts are electrostatic paint. It is used in (Optional) double side with back side thanks to mounting frame on table top with sigma profile and suitable for easy installation of modules. There is a table part on the side where the students work for easy experimentation. They are designed according to the height to which they can easily reach. DC Power Supply: 1 x 0-30 V 0-2A Current Control, 1 Voltages, 1 current measuring instruments, Short-circuit protection o (Optional) Frequency Generator 0-200kHz, Sine, Triangle, Square output. 6 step Frequency Select Feature, DC OFF / SET setting +/- 4V, Output 50 Ohm, 600 Ohm or AC, Output Attenuation -20dB, -40dB, -60dB o AC 12V V Outputs o DC - 12 and +12 V Fixed Symmetrical, Adjustable 1A V, V, + 5V and - 5V 1A Short-circuit protected Power Supply o Outputs LED with Indicator. o 3 lamp modules with 12V fences. o AC 220V 50Hz grounded monophase 3-pole plugs, AC 380V 3-pole triple pole are available. o 220V 50Hz output for use in experiments with distortion-proof cabling suitable Plug outs ( phase and neutral) (Optional 3 phase) It is available. o Emergency stop button, Leakage current relay, Fuses are integrated in the set. o There is a central lock that can be opened by the teacher. o Pilot lamps are available for each phase showing operating status o Connection cables with 4mm plugs in various colors and length (plug-in) o It is designed with navy supporting all experiments. Cables and sockets are special construction protected against warping.

7

8 Basic Installation and Security Systems Experimental Modules Basic Installation and Safety Systems Experimental Set It has a modular structure. Experimental Modules in Modular Structure The system applications can be made by making desired energy and installation connections on AC / DC Energy Quality Laboratory Desk. Experimental Modules, Circuit Panel and Panel Insulated Over Panel. All inputs and outputs are double insulated 4mm banan socket. Connection cabling is shielded against warping. It has been processed with CNC so that the Text and Symbols located on the Experiment Modules enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Module are designed to be indelible and non-scratchable. The basic installation test set with optional selection consists of the following Test Modules: Electrical Installation Application Set Ringtones Transformer Door Automation Ladder Light Automation Diaphone Power Plant Doorphone unit Entrance Door Lighting socket module 4 Ringtones Button and speaker

9 Porcelain type E27 sockets Garden Lighting On / Off switch 4 pcs On / Off Single 4 pcs. 220V socket Telephone socket Television Antenna Socket Vavien switch ON/OFF Light Switch

10 Electrical Installation Application Modules Dimmer Switch Digital single-phase electricity meter Fuse 32A 3 phase Fuse 20 A 3 phase Door ring Phone terminal box Jalousie module 12V DC Call system module Call Numerator Module

11 Addressable Fire Alarm System Application Set Addressable Fire Detection System Implementation Set It has a modular structure. Experimental Modules in Modular Structure The system applications can be made by making desired energy and installation connections on AC / DC Energy Quality Laboratory Desk. Experimental Modules, Circuit Panel and Panel Insulated Over Panel. All inputs and outputs are double insulated 4mm banan socket. Connection cabling is shielded against warping. It has been processed with CNC so that the Text and Symbols located on the Experiment Modules enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Module are designed to be indelible and non-scratchable. The Admissible Fire Detection System Application Set with optional selection consists of the Experimental Modules specified in the following: Smoke Modul Addressable Smoke Detector Optical Address Gas Detector (LPG - LNG) Experiment Module Addressable Fire Alarm Central Experiment Module Addressable Fire Alarm Button Addressing Module Flasher Siren

12

13 Wired Burglar Detection Power Plant Experiment Module Wired Thief Detection connection module Wired Thief Detection System Implementation Kit It has a modular structure. Experimental Modules in Modular Structure The system applications can be made by making desired energy and installation connections on AC / DC Energy Quality Laboratory Desk. Experimental Modules, Circuit Panel and Panel Insulated Over Panel. All inputs and outputs are double insulated 4mm banan socket. Connection cabling is shielded against warping. It has been processed with CNC so that the Text and Symbols located on the Experiment Modules enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Module are designed to be indelible and non-scratchable. The optional Wired Thief Detection System Application Kit consists of the following Modules:

14 Kablosuz Hırsız Algılama Sistemi Uygulama Seti Glass breaking module Pir (Motion) Detector (Motion Detector) (Ceiling Type) External Siren Magnetic contact sensor Keyped

15 Wireless Burglar Detection System Wireless Burglar Detection System Implementation Kit It has a modular structure. Experimental Modules in Modular Structure The system applications can be made by making desired energy and installation connections on AC / DC Energy Quality Laboratory Desk. Experimental Modules, Circuit Panel and Panel Insulated Over Panel. All inputs and outputs are double insulated 4mm banan socket. Connection cabling is shielded against warping. It has been processed with CNC so that the Text and Symbols located on the Experiment Modules enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Module are designed to be indelible and nonscratchable. The optional Wireless Thief Detection System Application Kit consists of the following Experimental Modules: Wireless Keypad RF Reciever Module Wireless Intruder Detection Unit Wireless Glass Breakage Wireless external siren Wireless Magnetic sensor Wireless motion sensor

16 Building (Home) Security System Application Building (Home) Security System Application Set It has a modular structure. Experimental Modules in Modular Structure The system applications can be made by making desired energy and installation connections on AC / DC Energy Quality Laboratory Desk. Experimental Modules, Circuit Panel and Panel Insulated Over Panel. All inputs and outputs are double insulated 4mm banan socket. Connection cabling is protected against warping. It has been processed with CNC so that the Text and Symbols located on the Experiment Modules enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Module are designed to be indelible and nonscratchable. The Building (Home) Security System Application Set, which has the possibility of optional selection, consists of the following Experimental Modules: Güvenlik Santrali Deney Modülü Smoke detector Address Gas Detector (LPG - LNG) Wired Glass Breakage Water Security Detector Detector Emergency Warning Button Wired motion detector Wired Magnetic sensor Wired Keypad Module

17 Intercom System Application Intercom System Application Set Has a modular structure. Experimental Modules in Modular Structure The system applications can be made by making desired energy and installation connections on the AC / DC Energy Laboratory Desk. Experimental Modules, Circuit Panel and Panel Insulated Over Panel. All inputs and outputs are double insulated 4mm banan socket. Connection cabling is shielded against warping. It has been processed with CNC so that the Text and Symbols located on the Experiment Modules enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Module are designed to be indelible and non-scratchable. The optional Intercom System Application Kit consists of the following Test Modules:. Intercom Central Unit Intercom Modul 1.Communication phone 2. Communication phone Automatic Door Module

18 Video Intercom System Application Modules Video Intercom System Application Kit It has a modular structure. Experimental Modules in Modular Structure The system applications can be made by making desired energy and installation connections on the AC / DC Energy Laboratory Desk. Experimental Modules, Circuit Panel and Panel Insulated Over Panel. All inputs and outputs are double insulated 4mm banan socket. Connection cabling is shielded against warping. It has been processed with CNC so that the Text and Symbols located on the Experiment Modules enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Module are designed to be indelible and nonscratchable. The Video Intercom System Application Kit with optional selection consists of the following Experimental Modules: Ring Buton Modul Video Switchboard Video Intercom Module1 Video Intercom Module2 Display Panel and Ring Distributor Module 1 DisplayPanel and Ring Intercom Central Unit Automatic Door Module Module 2

19 Conventional Fire Detection System Application Set Has a modular structure. Experimental Modules in Modular Structure The system applications can be made by making desired energy and installation connections on AC / DC Energy Quality Laboratory Desk. Experimental Modules, Circuit Panel and Panel Insulated Over Panel. All inputs and outputs are double insulated 4mm banan socket. Connection cabling is shielded against warping. It has been processed with CNC so that the Text and Symbols located on the Experiment Modules enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Module are designed to be indelible and non-scratchable. This set consists of the following Test Modules: Temperature sensor Optic smoke dedector Addressable Gas Detector Wire less Siren IR Dedector Fire Warning Wireless Burglar Central Detection

20 Relay temperature sensor Flash Siren Relay optic sensor Card Door Access System Application Modules Card Door Access System Has a modular structure. Experimental Modules in Modular Structure The system applications can be made by making desired energy and installation connections on AC / DC Energy Quality Laboratory Desk. Experimental Modules, Circuit Panel and Panel Insulated Over Panel. All inputs and outputs are double insulated 4mm banan socket. Connection cabling is shielded against warping. It has been processed with CNC so that the Text and Symbols located on the Experiment Modules enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Module are designed to be indelible and non-scratchable. The Card Door Transition System with optional selection consists of the Experimental Modules specified in the following: Keypad Module Automatic Door Module

21 LOW and HIGHT Current Electrical Installation Applied Training Panels It was processed with CNC so that the Text and Symbols placed on the Experiment Panel would enter 1 mm in order not to be erased over time. Thus, the Text and Symbols on the Clipboard are designed to be indelible and non-scratchable ES Hight Current Installation Application Board 1 (93X122cm) It is designed for the application of basic high current electrical installations in AC Electrical Systems to under-floor materials. Application Platform and Power Unit Application Platform. Energy Unit: 2x25A 30mA leakage current protection switch, 1x 10A With automatic fuse, emergency stop and start - stop button, grounded pit and banana plug outlet. The fuse box, box, case, lamp outlet and pipes are installed according to different installation practices. The only line diagram showing the laying of flush-mounted elements. Power and Control Circuit supply line is located. It is suitable for mounting in a wall or work console. There are minimal installations that can be applied. There is a normal, commutator and light-brass installation with a vaulted switch. There is a lighting system with stair automation and pulse current switch. In applications, wire drawing, connection of elements and operation of circuits can be done. ES Strong Current Installation Application Board 2 (93X122cm) It is designed to be used in AC Electrical Systems, Basic Strong Current Distribution Devresin Plastered Materials. Application Platform and Energy Unit. Energy Unit 2x25A with 30mA leakage current protection switch 1x 20A with automatic fuse, emergency stop and start-stop button, grounded buzzer and banana plug output. The meter box is laid out as a fuse (lane) distribution box, a box, a safe, a lamp outlet, and a light - bridged lane and sortie of pipes. The only line diagram showing the laying of flush-mounted elements. There is an energy and control feeder line. It is suitable for mounting in a wall or work console. There are minimal installations that can be applied. There is a basic deployment application. Counter connection is available. There is a distribution table application. The Piriz line - sorti application is available. There is a light line sorting application. In applications, wire drawing, connection of elements and operation of circuits can be done.

22 ES Low Current Installation Application Board 1 (93X1 22cm) It is designed for the application of basic, low current electrical installations in AC electrical systems. There is a Platform for Weak Current Installations in the Application Panel and the Energy Unit. Energy unit: 2x25A with 30mA leakage current protection switch with 1x 6A automatic fuse, emergency stop and start-stop button, grounded prime and banana plug output. The box, bucket, outlet chute and pipes are laid out according to different application practices. It is the only hatchema drawing showing the laying of the elements under plastering. The energy and control supply line is suitable for mounting on the wall and work console. There are minimal installations that can be applied. There are button bell installations available. There is a mutual invocation system application. Numerator and door automation system applications are available. In applications it is known to draw cables, connect the elements and operate the circuits ES Low Current Installation Application Board 2 (93X1 22cm) Basic Weak Current in AC Electrical Systems is designed for all - in - one (call, nummer, door automat etc.) TV - television distribution systems to be applied with flush - mounted materials. There is a Weak Current Installation Application Platform consisting of Application Panel and Energy Unit. Energy unit: 2x25A 30mA leakage current protection switch with 1x 6A automatic fuse, emergency stop, start-stop and banana plug output. It has a buttoned, grounded pit and banana plug. The casing is laid out in a structure to be applied to the bucket outlet block, the pipe v.s composite low current installation. It is the only hatchema drawing showing the laying of the elements under plastering. Power and control feed line. It is suitable for mounting on the wall and work console. There are minimal installations that can be applied. There are button bell installations available. The complex is equipped with a low flow (call - dialer - door automation) installation. TV-phone installations are available for deployment. In applications it is known that cable traction, connection of elements and operation of circuits are possible.

23 ES50 Electrical Safety Measures Test Set The use of electric energy is at every stage of our lives and as an energy that people use everywhere. Houses, kitchens, workplaces, schools, hospitals etc. have a wide range of uses. However, electrically operated appliances, all appliances with electrical power, are also exposed as a danger area at the same time. This is a test set made to teach students about the dangerous side of the electricity and the precautions to be taken, the rules of conformity of TSE(VDE) standarts, the practical simulations to be done in education and experiments, Structure The Experiment Set consists of templates that will be used in experiment with the main device which is designed for desktop usage and contains all necessary equipment and voltage sources to be used in experiments. The set, which is supported by the Turkish test book, is designed to be used for training purposes. The templates and connection cables provided with the set and the experiments in the book content are established by the student and the measurements are made. Experiment Contents The in English experimental book supplied with the experiment kit is prepared from the subjects which are designed for the practical training of the rules related to the conditions suggested by the institutions such as the Chamber of Professionals and the TSE (VDE) Standarts, including the schematics, exercises and answers. Directives of the Code Installation diagrams of various templates to be used in experiments Questions and assignments Responses to homeworks and questions Provisions of the Code of Conduct on Electrical Safeguards: 1. Direct contact with an active part 2. An indirect contact test with an active part 3. Conservation experiments with protection class II or equivalent isolation 4. Insulation and Insulation tests 5. Low Voltage SELV (System Earth Light Voltage), Low Voltage PELV (Protection Earth Light Voltage) experiments 6. Protection measures in the TT system: High current fuse protection tests 7. Protection measures in the TT system: Grounding sample tests with earthing bar 8. Earth resistance measurements and tests in TT system 9. High current fuse tests in TN systems 10. Impedance tests in TN systems 11. Ground resistance tests in TN systems 12. RCD experiments 13. RCD experiments in TT systems 14. Experiments to notify insulation faults in IT systems

24 Technicial Specifications: Experiments are carried out at levels that do not endanger life Experiment templates are designed in clear schematics and symbols. Attach the template to be tested and experiment with connection cables and short circuit plugs. Designed and used as 23V AC and 40V AC in the 230V AC and 400V AC experiment set used in normal operation. The values obtained in this count and the measurement results are simply multiplied by 10 to find the value in actual use. Test set operating voltage 220V 50 Hz. The mains voltage is. Triphase voltage generator integrated in the device allows 3 phase tests. Device dimensions: (Approx.) 580mm x 350mm x (Front) 8mm / (Back) 15mm Options included in Set Test Templates 2mm PVC 7 pcs 2mm connection cable set 10 pieces 40cm, 5 pieces 30 cm, 5 pieces 20 cm, 5 pieces 10 cm 10mm short circuit plugs (with special spring and gold plating for oxidation) 26 units 220V AC grounded / plug connection cable English Student and Teacher book, question answers, book of experimental solution

25 ÇOKESEN ELEKTRONİKSan. Tic. Ltd.Şti Bağlarbaşı Mh. Şehit Mücahit Sk. No: Maltepe - İSTANBUL Tel: : : Fax : cokesen@cokesen.com w w w. c o k e s e n. c o m

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS CHAPTER 15: TRAINING SYSTEMS FOR ELECTRICAL INSTALLATIONS 527 Training Panel to Electrical Protective Measures 528 Training Panel to Installation Tests

More information

Innovative EEE mini-projects list

Innovative EEE mini-projects list 1 Innovative EEE mini-projects list SEM-133. Checking and auto control of water level using wireless sensor. SEM-140. Wireless 3-phase motor starter using RF technology. SEM-185. Designing of Haptic Keypad

More information

Intelligent Addressable Fire Alarm System

Intelligent Addressable Fire Alarm System Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of

More information

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. Preface Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. The GSM Security Alarm ( The Alarm ) adopts the most advanced

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

MICANS INFOTECH

MICANS INFOTECH EEE/ECE/EIE/ICE/ROBOTICS/BIOMEDICAL 2017-2018 PROJECT TITLE 1. IR sensor based walking stick for the blind people 35 Microcontroller Based Prepaid card for petrol bunk 2. Industrial fire warning system

More information

UEE30811 Q-Tracker Work Tasks

UEE30811 Q-Tracker Work Tasks UEE30811 Q-Tracker Work Tasks UEENEEC020B Participate in electrical work and competency development activities Q-Tracker requirements: 40 hours of practical training. 1. Comply with electrical industry/enterprise

More information

Product Catalogue Fire and Intrusion Alarm Systems

Product Catalogue Fire and Intrusion Alarm Systems Product Catalogue Fire and Intrusion Alarm Systems 2017 www.edselectronic.com FIRE ALARM SYSTEMS SOUNDER ECSO22R 100-120dB Piezo buzzer Red LED indicator Indoor Sounder ECSI20 85-100dB Piezo buzzer Single

More information

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements INDEX 1 NETIC... 2 2 Door/Window detector MINI... 2 3 FOUR sensor... 3 4 Smoke detector... 3 5 Flood detector... 4 6 ILLumination sensor... 4 7 Lamp holder... 5 8 Siren... 5 9 Power meter & switch... 6

More information

your silent and loyal servant

your silent and loyal servant Easy installation, simple programming! your silent and loyal servant The GD-04 is a GSM remote controller-sensor. It sends SMSes, calls - switches on/off and guards. DAViD cannot speak but is understood

More information

Supervised Security System Owner's Guide

Supervised Security System Owner's Guide Owner's Guide PSC06 READ THIS FIRST This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturers instructions,

More information

Personal Assistance System Owner s Manual

Personal Assistance System Owner s Manual Personal Assistance System Owner s anual 3 3 O UNT A C K G HOUS RCORD nstall Run AC Power Battery Low 4 2 8 3 6 PROG 0 RCORD Personal Assistance System PA800 RAD THS FRST This equipment generates and uses

More information

MY HOME LaYOut Of the building 22

MY HOME LaYOut Of the building 22 22 MY HOME Layout of the building LAYOUT OF THE BUILDING SECTION CONTENTS General rules for installation 24 Type of wiring 28 Devices in flush-mounting boxes 30 Devices in surface-mounting boxes 32 Rules

More information

QA16 Addressable System

QA16 Addressable System QA16 Addressable System Operating Manual HORING LIH INDUSTRIAL CO., LTD. www.horinglih.com QA16 System Characteristics Each loop can connect with 250 devices. Easy system programming through PC to panel.

More information

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers Intrusion Systems UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers Up to 6 UEZ LSNs can be networked with system loop technology (SRT) Fire

More information

Sonic Safety. Sonic Safety. Wireless Safety and Security System. HG-1500 System. For System Package OWNER S MANUAL

Sonic Safety. Sonic Safety. Wireless Safety and Security System. HG-1500 System. For System Package OWNER S MANUAL Sonic Safety Sonic Safety Wireless Safety and Security System HG-1500 System For System Package OWNER S MANUAL Table of Contents Introduction (HG-1500).. 3 System Package. 3 Optional Accessories.. 3 Deployment

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC

More information

DIY Home Security Support 30 numbers wireless sensors

DIY Home Security Support 30 numbers wireless sensors 1. Package includes 1.1 Standard (1) One main unit (black, white) (2) One adapter (3) One remote controller (4) One wireless P.I.R motion detector (5) One telephone line 2. Outward introduction 2.1 Main

More information

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual ANALOX 5001 ANALOX 5001 Carbon Dioxide Monitor User Manual Analox Sensor Technology Ltd 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT T: +44 (0)1642 711400 F: +44 (0)1642 713900

More information

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description Loop Detector is used to detect metal objects such as motor vehicles, motor bikes or trucks. ELSEMA Features Wide supply range: 12.0 to 24 Volts DC 16.0 to 24 Volts AC Selectable sensitivity Pulse or Presence

More information

Audio Related Projects

Audio Related Projects Audio Related Projects 1. Electronic Organ 2. Low-Cost Telephone Amplifier 3. Using Loudspeaker as a Microphone 4. Graphic equalizer 5. Automatic school bell 6. Police siren 7. 3.5W Audio Amplifier 8.

More information

Universal Clamp Meter

Universal Clamp Meter Universal Clamp Meter Instruction Manual 489D F1365-04 10337881 489D UniversalClampMeter Instr.indd 1 5/11/2007 10:37:49 AM Table of Contents 1. Features...3 2. Specifications...4 3. Designations...5 4.

More information

Training systems for electrical installation technology

Training systems for electrical installation technology Training systems for electrical installation technology Practical, project-oriented treatment of building management systems 3rd edition Contents Qualifications Through Quality Training Systems for Electrical

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

Quotation of inels system

Quotation of inels system Quotation of inels system CUSTOMER Name: Surname: Phone: Email: REALTY Description: Place of implementation: Number of rooms: Useful fl oor area: TECHNOLOGY The Heating Source Electricity Gas Solid fuels

More information

Public Address Project Combisound System

Public Address Project Combisound System Public Address Project Combisound System Roberto Bono sat@eissound.com 900502285 Index Introduction:... 2 General description... 3 Technical descriptions:... 4 Public Address Central Unit... 4 Loudspeakers,

More information

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL DISTRIBUTION SYSTEM:?? The existing electrical service consists of an underground primary service originating at a utility pole on Cedar Street,

More information

The complete wirefree security alarm solution

The complete wirefree security alarm solution The complete wirefree security alarm solution www.espuk.com Wirefree home security and management system Infinite prime offers the professional installer a comprehensive and reliable intruder alarm solution

More information

Quick Programmer s Manual

Quick Programmer s Manual Version 2.604 (31/03/05) p1 Quick Programmer s Manual 2005. Inner Range Pty. Ltd. Part Number: 630048V2 p2 Version 2.604 (31/03/05) TABLE OF CONTENTS. 1. PROGRAMMING FLOWCHART. The following flowchart

More information

JA-63 Profi User manual

JA-63 Profi User manual JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...

More information

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection Ground Fault Protection GADD MKIII Ground Fault Indication System Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472 Toll Free: 1-888-RESISTR

More information

Hardwired Alarm Accessories

Hardwired Alarm Accessories Hardwired Alarm Accessories Contents Wireless Door Contact for WGAP864 WGAP864WDCV2...3 Wireless PIR Sensor (Pet Immunity) For WGAP864 WGAP864WPIRV2...4 Dual Technology PIR / Microwave Detector ALH-PIRMW...5

More information

Conventional Fire Alarm System Product Range Guide

Conventional Fire Alarm System Product Range Guide EXPERT IN SAFETY AND SECURITY TECHLOGY CONTENTS Conventional Fire Alarm System CK1004 Conventional Fire Alarm Control Panel CK1008 Conventional Fire Alarm Control Panel CK10016 Conventional Fire Alarm

More information

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy. Installation manual detector and controller Code no. 20711062 Page 1/30 CONTENTS Controller... 2 Function of the Relays... 2 Gas Detectors... 2 Cabling... 4 Mechanical Installation of the gas detectors...

More information

HOME AUTOMATION GUIDE TO THE HOME AUTOMATION SYSTEM

HOME AUTOMATION GUIDE TO THE HOME AUTOMATION SYSTEM HOME AUTOMATION GUIDE TO THE HOME AUTOMATION SYSTEM Quick Guide Rules for installing the By-me system Introduction This guide groups ten basic rules for creating a home automation system with the By-me

More information

Advanced DIGITAL Wired PIR Motion Detector

Advanced DIGITAL Wired PIR Motion Detector PRELIMINARY Advanced DIGITAL Wired PIR Motion Detector The PIRfect PYR-2021 provides DIGITAL Passive Infra Red (PIR) motion detection across a volumetric area, with versatile advanced SPHERICAL SEALED

More information

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority. Fitness Facility Addition Page 1 1.1 CODES AND STANDARDS.1 Do complete installation in accordance with the latest edition of the CSA C22.1 as amended by the latest editions of the National Building Code

More information

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

More information

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! GSM SMS Controller DCS-130 User Manual Ver 1.20 Date Issued: 14-9-2010

More information

DS7400Xi Addressable Control/ Communicator

DS7400Xi Addressable Control/ Communicator DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems

More information

Product Data Sheet. Remote Terminals. Features:

Product Data Sheet. Remote Terminals. Features: Remote Terminals Product Data Sheet Features: Based around two core products, the Mx- 4010 Remote Display Terminal (RDT) and the fully functional Mx-4020 Remote Control Terminal (RCT). Both remote terminals

More information

GSM House Alarm System. User Manual. Ver 1.20 Date Issued:

GSM House Alarm System. User Manual. Ver 1.20 Date Issued: GSM House Alarm System User Manual Ver 1.20 Date Issued: 2010-05-14 Table of Contents 1. Brief introduction -----------------------------------2 2. Safety Directions -----------------------------------2

More information

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate. This safety certificate is an important and valuable document which should be retained for future reference DETAILS OF THE CLIENT Client / DETAILS OF THE INSTALLATION Extent of the installation covered

More information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required

More information

IEEE Transformer Committee PC Distribution Transformer Monitoring - User

IEEE Transformer Committee PC Distribution Transformer Monitoring - User IEEE Transformer Committee PC57.167 Distribution Transformer Monitoring - User Mark Scarborough Electrical Engineering Consultant DuPont January 9, 2019 Transformer Types in DuPont Control power Dry-type

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

MOBILE CALL GSM Alarm System User s Manual

MOBILE CALL GSM Alarm System User s Manual MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm Host Diagram

More information

CODESEC FIRE ALARM SYSTEMS. security technologies

CODESEC FIRE ALARM SYSTEMS. security technologies CODESEC FIRE ALARM SYSTEMS security technologies AA402 ADRESSABLE FIRE ALARM CONTROL PANEL AA402 Electronic Addressable Intelligent Fire Alarm Control Panel Onboard one loop, 250 nodes per loop, Metal

More information

3226 Trunk Port FXO Doorphone

3226 Trunk Port FXO Doorphone 3226 Trunk Port FXO Doorphone Installation and User Guide Algo Communication Products Ltd., Burnaby, BC Canada V5J 5L2 www.algosolutions.com - 1 - Document #: 90-00040F Important Safety Notice The 3226

More information

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system

More information

TRX MAINS CONNECTION DIAGRAM

TRX MAINS CONNECTION DIAGRAM TRX MAINS CONNECTION DIAGRAM Switch 230VAC 10A Neutral Out Phase Out TRX MAINS Phase In Neutral In LOAD 8A MAX. Specifications: Operating Voltage: 220-240VAC 50Hz Current Draw: 5mA Max. Switching Current:

More information

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47) DIESEL ENGINE CONTROL UNIT DCU 205 - USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) 64 84 52 00 Fax: (+47) 64 84 52 12 office@auto-maskin.no - 1 - TABLE OF CONTENTS 1. INTRODUCTION TO THE DCU 205...4

More information

Monitoring Devices 11/1

Monitoring Devices 11/1 11/4 Introduction 11/6 5TE5 8 light indicators 11/7 4AC3 0, 4AC3 1 bells, buzzers 11/7 5TT3 46 fault signaling units 11/8 7LQ2 1, 5TT3 3 dusk switches 11/9 7LQ2 0 temperature controllers 11/9 5TT3 170

More information

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System GSM Alarm System System disarmed 11/26/2013 User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS

More information

HG Home Guardian Advanced Home Energy, Safety and Security Management

HG Home Guardian Advanced Home Energy, Safety and Security Management Product Sheet CT2.12 Controller Type HG HG Home Guardian Advanced Home Energy, Safety and Security Management EH Home Guardian TM is an intelligent control and monitoring unit for your house or holiday

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

U ser's Guide PC6010

U ser's Guide PC6010 User's Guide PC6010 Quick Reference Guide This manual is for Basic and Advanced users. Each of these types of user can access a different set of functions. The and symbols next to the title of each procedure

More information

EMBEDDED BASED PROJECTS

EMBEDDED BASED PROJECTS EMBEDDED BASED PROJECTS 1. Real time data acquisition system. 2. Traffic priority for ambulance vehicle. 3. Train collision avoiding system. 4. Remote control switching system. 5. Dtmf switching. 6. Rtc

More information

PART 4 ELECTRICAL STANDARDS

PART 4 ELECTRICAL STANDARDS PART 4 ELECTRICAL STANDARDS 1.0 INTRODUCTION AND SCOPE: These standards reflect the general requirements and recommendations of elevator contractors, with respect to the power distribution system to achieve

More information

ACP10 & ACP50 Security Systems

ACP10 & ACP50 Security Systems ACP10 & ACP50 Security Systems System Configuration LCD Keypad LCD Keypad LED Keypad LED Keypad 4-wire Bus ACP10 & ACP50 AEX10* AEX10* AEX10* AEX10* * ACP50 Only Control Panels The ACP10 control panel

More information

«Smart Home Technology» by Quadrobit: security energy comfort

«Smart Home Technology» by Quadrobit: security energy comfort «Smart Home Technology» by Quadrobit: security energy comfort "Smart home" is an ecosystem of your home of your safety and comfort "Smart home" is no longer a luxury, it is a necessary tool for the safety

More information

Call stations and extensions

Call stations and extensions Novigo Call stations and extensions PT2001-A1, PT2002-A1, PT2008-A1, PT2009-A1, PTO2001-A1, PTO2002-A1, PTO2003-A1, PTO2004-A1, PTO2005-A1, PTO2006-A1, PTO2008-A1 EN 54-16-certified alarm and business

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

All-In-One Wireless Security System V1.0. Model #: MG-6060

All-In-One Wireless Security System V1.0. Model #: MG-6060 All-In-One Wireless Security System V1.0 Model #: MG-6060 Reference and Installation Manual DRAFT Table of Contents Introduction... 5 About Magellan and this Manual... 5 Conventions... 5 Specifications...

More information

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System By shield4u http:// (Version 20110816) A. Alarm Understanding Away Disarm Home Emergency Function Signal Interpretation Buzzer

More information

BS-100 DYFI. Installation handbook. Protecting environment, life and property... P-BS100/DCE

BS-100 DYFI. Installation handbook.  Protecting environment, life and property... P-BS100/DCE BS-100 DYFI Protecting environment, life and property... P-BS100/DCE P-BS100/DCE/Doc/961023 2 Autronica Fire and Security AS Contents Please observe! This handbook contains installation instructions for

More information

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that

More information

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10 Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

GSM Alarm System. S120 User Manual. Ver 1.00 Date Issued:

GSM Alarm System. S120 User Manual. Ver 1.00 Date Issued: GSM Alarm System S120 User Manual Ver 1.00 Date Issued: 2010-09-01 Website: Http://www.thebest-plus.com Table of Contents 1. Brief introduction -----------------------------------2 2. Safety Directions

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information

Alarm System. Enjoy the Security. Enjoy Simple Life KERUI Doorbell. Security and Protection. Leading Brand of Intelligent. Present by Secrui Group

Alarm System. Enjoy the Security. Enjoy Simple Life KERUI Doorbell. Security and Protection. Leading Brand of Intelligent. Present by Secrui Group Enjoy the Security Alarm System Leading Brand of Intelligent Security and Protection 中国移动 GSM 11:25 Enjoy Simple Life KERUI Doorbell Present by Secrui Group Shenzhen Secrui Electronic Co., ltd is a professional

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual All-In-One Wireless Security System V1.0 Model #: MG-6060 Reference and Installation Manual Table of Contents Introduction... 3 About Magellan and this Manual... 3 Conventions... 3 Specifications... 3

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Vista-50P/-50PUL System Design Sheet

Vista-50P/-50PUL System Design Sheet Vista-50P/-50PUL System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-50P (Nine Hardwired Zones, One Addressable Loop, Wireless)

More information

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE FINAL DISTRIBUTION PRODUCTS RANGE ISO 14001:2004 Certified ISO 9001:2008 Certified FUSES INDIA LTD Lawson Fuses India Ltd is a wholly owned subsidiary of Lawson Fuses Ltd,a long established UK company

More information

The WAVE Plus Instant Notification System for Schools and Colleges

The WAVE Plus Instant Notification System for Schools and Colleges Instant Notification System for Schools and Colleges Duress alarm has been activated in the School of Engineering! Schools strive to provide a safe environment for students and teachers. In an emergency,

More information

Telecity. Table of Contents. Page. Section 3.2

Telecity. Table of Contents. Page. Section 3.2 1 3.2 System Descriptions Table of Contents 3.2 SYSTEM DESCRIPTIONS... 3 3.2.1 General Notes... 3 3.3 Power Distribution MV... 4 3.3.1 Incoming Supply... 4 3.3.2 MV Switch room... 4 3.4 Power Distribution

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) IR425-D4_D00039_04_D_XXEN/05.2017 ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits

More information

GSM RFID VOICE Alarm System

GSM RFID VOICE Alarm System GSM RFID VOICE Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS [Function Instruction] [Control Panel] Control Panel

More information

OPTICAL SMOKE DETECTOR Model: SPD-KADET

OPTICAL SMOKE DETECTOR Model: SPD-KADET OPTICAL SMOKE DETECTOR Model: SPD-KADET USER S MANUAL "ARTAR-PLUS" company 6 Prutska street Chernivtsi 58008 Ukraine EN 54-7 For further information please contact us: +38 0372 584373 www.artarplus.com.ua

More information

Vista-20SEUL System Design Sheet

Vista-20SEUL System Design Sheet System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO SECTION 1: Basic -Features QED programming for quick enrollment of devices (Eight Hardwired Zones, Wireless) Part

More information

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using. V1.0 Smart Home Alarm System User Manual APP download via QR Code scanning Please read the manual carefully before using. Content FUNCTION PROFILE 2 THE SCHEMATIC GRAPH OF HOST 3 PROCESS OF BOOTING 6 OPERATION

More information

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Installation instructions VITODENS 200-W. for contractors Installation instructions for contractors VIESMANN Vitodens 200-W Type WB2C, 45 and 60 kw Wall mounted gas condensing boiler Natural gas and LPG version VITODENS 200-W 1/2010 Dispose after installation.

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY. SK642 WIRELESS WATER ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL AND SET UP INSTRUCTIONS. Thank you for choosing Ideal Security s Wireless Water Alarm with Telephone Dialer. Please read through complete

More information

Operating Instructions

Operating Instructions D-TEK Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product

More information

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC Take Fire Protection to the Next Level Fire Products from DSC AFD2000 Addressable Fire Control Panel Series Provides Maximum Flexibility The new AFD2000 is a completely programmable series of addressable,

More information

System. For a better understanding of this product, please read this user manual thoroughly before using it.

System. For a better understanding of this product, please read this user manual thoroughly before using it. GSM Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Control Panel Introduction Chapter 3.

More information

FR-A180 FR-A360. Occupancy detector. Use

FR-A180 FR-A360. Occupancy detector. Use 5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable

More information

CM800 Emergency Call System

CM800 Emergency Call System Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734 tektone@tektone.net Fax: 828.524.9968 Copyright

More information

Speed and Frequency Seite 1 von 7

Speed and Frequency Seite 1 von 7 Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.

More information

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions EN54-3:2001+A1:2002+A2:2006 EN54-7:2000+A1:2002+A2:2006 EN54-25:2008 0359 Electro Detectors Ltd. Electro

More information

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES Prem1er EVACS16 VOICE ALARM CONTROL PANEL 4 16 ZONES Installation Manual Approved Document No: GLT.MAN-141 PAGE 1 INDEX INDEX... 2 Summary... 3 Safety information & use of this manual... 5 Installation

More information

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214

More information

S3 Sim Secual Alarm system with GSM transmitter

S3 Sim Secual Alarm system with GSM transmitter S3 Sim Secual Alarm system with GSM transmitter www.etiger.com Features Control Panel Layout (Back) - ARM CPU + Auror CPU - GSM frequency: 850 / 900 / 1800 / 1900 MHz, suits all phones - Supports up to

More information

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System USER S MANUAL System disarmed 00/00/00 00:00 ARM STAY CALL 1 2 3 4 5 6 7 8 9 Power Set Signal Alarm SOS ESC 0 ENTER Profile For a better understanding of this product, please

More information

5000 INSTALLATION GUIDE

5000 INSTALLATION GUIDE 5000 INSTALLATION GUIDE Table of Contents Section Page No 1. INTRODUCTION... 3 2. WARNINGS AND CAUTIONS... 3 3. UNPACKING... 3 4. INSTALLATION... 4 5. CONTROL PANEL - REMOVING ITEMS BEFORE MOUNTING...

More information