Do you know the three blind spots of traditional aspirating smoke detector system?
|
|
- Millicent Rogers
- 5 years ago
- Views:
Transcription
1 Sensitive smoke detector UL-approved ( File No. S25270 ) Do you know the three blind spots of traditional aspirating smoke detector system? ❶ Smoke area unspecifiable due to collective aspiration from suction pipe. ❷ True detection impossible due to smoke dilution in suction pipe. ❸ Slow detection if suction area and control unit are distant. Aspirating smoke detector Smoke suction pipe Detection Sensor Line of Power & data transmission Air circulation Smoke flow Smoke concentration data transmission We provide you with the best solution.
2 An ultimate sensitive smoke detector system realized by Fenwal Controls of Japan, Ltd. Suction Alarm System:The smoke area can be specified quickly because of the smoke detector module which has set addresses. Advanced sensitive smoke detector & control unit with built-in suction fan Alarm address display the pre-alarm and alarm is quickly sounded according to the set level. It demonstrates its effect when set it in places where smoke emission may occur such as power supply devices or running gears. Inside server rack Power supply devices in factory Semiconductor test equipment FA production line robot running gear
3 which has a track record with its disaster prevention system for large facilities and factories in the industrial world. Settings examples The SAS (Suction Alarm System) enables appropriate placement of detector that suit site condition and building structure. Direct method Detection module Abnormalities can be identified with instantaneous detections even in large spaces since each detector aspirates smoke. Semiconductor test equipment FA line Communication equipment room Radio broadcast place Food manufacturing line, etc. Tube method Detection module It is possible to extend a tube from the detector and precisely detect any abnormalities even with closely divided powered equipment in cubicles. Distribution board Server Power supply unit, etc.
4 By connecting with a computer, the situation can be fully grasped from the monitoring room. 1 Trend graph display features Trend graph which displays time series data of smoke concentration variation, can be displayed about each address. 4 Condition display features Current conditions of each address can be displayed so that a user can check alarm levels and troubles etc. 2 Alarm/pre-alarm setting up function Up to 31 detectors are connectable to a control unit. Each address can be set alarm and prealarm level. 5 Control unit setting up function Upper/lower value of air flow, and number of detectors to connect can be set to a receiver. Further, system reset operation can be made. 3 History reporting features In total 1,023 of history data can be displayed and printed as a list. 6 Alarm signal reception display features (option) Address of detected modules and located places can be displayed on a layout drawing.
5 Detectors accurately detect the smoke area / condition. Traditional sampling method blind spots (E.g.) In a traditional system with a 0.1%/m sensitive smoke detector with 30 suction sockets Blind spot 1 Detection is impossible even if aspirated smoke has an above threshold concentration due to smoke dilution in suction tube. Even if concentrated smoke is aspirated, it is diluted before detection. Consequently, its concentration does not reach the threshold, and thus not detected. Even if 2%/m of concentrated smoke is aspired from the 30th socket, not only will the emission area not be specified, but, if the smoke flow from other sockets is equivalent to zero, the smoke concentration in the detector part will become 0.07%/m, and thus not be detected. Blind spot 2 Correct detection is impossible due to aspirated smoke being diluted in suction tube. Even if aspired smoke concentrations from a wide area reaches the threshold, the slightest dilution will render it to become undetectable. It will work if the 30 suction sockets aspirate a 0.1%/m concentrated smoke. However, if one of those sockets presents a smoke flow equivalent to zero, the smoke concentration in the detector part will decrease to 0.09%/m, and thus will not be detected. Blind spot 3 Smoke area will be unspecifiable and detection time will vary according to suction point with several suction sockets (our prior products). Even if smoke is detected, the source of emission cannot be specified. Detection time will vary according to suction point. Suction Alarm System g A sensitive smoke detection system that solves prior problems It is not influenced by smoke concentration inside suction sockets Detection module By setting individual addresses for the smoke detector modules, it is possible to specify the smoke area. 2 It is possible to set the sensitivity of each detector module within a range of 0.1%m to 3% of smoke concentration. 3 Cause each module will detect, time difference due to distance will not occur.
6 Aspirating Smoke Detector : SAS11- QY01-UL Classification Aspirating Smoke Detector Rated voltage DC24V 1.0mA Working voltage range DC24V ± 10% Current consumption 0.9mA or less (When DC24V is applied) Red LED Electrical Specification Monitoring state : Blinks once in 10 seconds Status indicator Alarm state : Blinks once in 2 seconds Trouble state : Lights out Restoration Alarm indication is self-maintaining(reset from Aspirating Control Unit SASC1-Y ) Range of alarm level 0.1%/m to 3%/m ( in 0.05% increments ) Address Address set for each detector (Address settings 01 ~ 63) Operating temperature range 0 to 37.8 Environmental Storage temperature range -20 to 70 Operating humidity range 30 to 85% RH (However, no condensation) Main material ABS(UL 94V-0) Mechanical Weight Approximately 180g Enclosure dimensions Height 100mm Width 102mm Depth 62mm Aspirating Control Unit : SASC1- Y-UL Classification Electrical Specification Environmental Mechanical of the UL certification Standard Category UL File No. Aspirating Control Unit Rated voltage AC100V 50/60Hz 80W Working voltage range AC 90 V to AC 240 V Connectable detector Number Up to 31 External wiring resistance 10 Ω or less (two way between receiving panel and detector) Typical from C Dry contact : Alarm, Pre-alarm, Trouble, Power interruption Contact output Typical from A Dry contact : Alarm Contact capacity:dc24v 1A Alarm Electric buzzer : Continuous ringing with alarm Intermittent ringing during trouble or pre-alarm Operation Transmission stop, sound stop, system reset External I/F RS-232C Port 1 Channel (D-Sub 9pin male) Operating temperature range 0 to37.8 Storage temperature range -20 to 70 Operating humidity range 30 to 85% RH (However, no condensation) Main material SPCC t = 1.2mm Weight Approximately 4.1kg Enclosure dimensions Height 170mm Width 260mm Depth 120mm UL268 Smoke Detector for Special Application (Code: URXG) S25270 Aspirating smoke detector module dimensional diagram Aspirating control unit dimensional diagram 170 (33) Grommet for PC line 39.5 (64) 25A pipe M3 Threaded holes for mounting a mute box Construction material Material Size Pipe Recommendation Rigid PVC pipe (VP pipe) 25A Color: White Type: Air conditioner drain pipe Wiring Type Maximum wire length Recommendation * Appearance and specifications are subject to change without any prior notice. Unauthorized duplication of the contents is strictly prohibited. * Catalog content is current as of July Shielded cable 1P 150m Adapted standard: J CS 5402 Color: White Product: F CPEV-NC cable 0.65mm X 1P made by Nihon Electric Wire & Cable Co., Ltd. fenwal. co. jp Head Office / Tokyo Business Office : Kyohan Kudan Building, Iidabashi, Chiyoda Ward, Tokyo JAPAN Phone: Fax: PE-821A OYK
Series Internal Detector
F Series Internal Detector Ultra-Small, ultra-high-sensitive smoke/heat It is also very important to take measures to protect equipment from fire Ultra-Small is 1/10 the size of conventional s, and 50
More informationSeismic Countermeasures for Environmental Radiation Monitoring System
Seismic Countermeasures for Environmental Radiation Monitoring System Osamu Maekawa Takeshi Miyairi Teruo Ebato ABSTRACT Environmental radiation monitoring system continually measures and monitors the
More informationVM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM
VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM Integrated Voice Evacuation System VM-3000 series Emergency Voice Alarm System Incorporating Digital Audio PA, Paging and BGM High-quality, compact public
More informationBionics Instrument. Alarm Handling. Gas Alarm Systems
Gas Alarm Systems Controllers and PLC based systems Alarm Handling Complete control at the right time and place Every gas detector consist of a gas sensor and a signal transmitter. In case of a gas leak,
More informationGMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number
Worldwide Supplier of Safety Solutions GfG Instrumentation 1194 Oak Valley Drive #20 Phone: 734-769-0573 Fax: 734-769-1888 E-Mail: info@gfg-inc.com Internet: www.gfg-inc.com GMA 301 Operation Manual Part
More informationRC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)
RC801/803/805-480B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,
More informationClass 1 laser beam sensor safe for your eyes
113 Sensor SERIES Related Information General terms and conditions... F-7 About laser beam... P.199~ Sensor selection guide... P.1~ General precautions... P.11 PHOTO PHOTO PARTICUR MEASURE ITY panasonic.net/id/pidsx/global
More informationAUR300C, AUR350C. Advanced Ultraviolet Burner Controller
No. CP-SS-7E Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD00C Advanced Ultraviolet Flame Detector. This AUR300C controls
More informationAnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION
AnaLASER II Detector High-Sensitivity Smoke Detector (HSSD ) F-89-250 FEATURES Air Sampling Smoke Detector for Early Warning Applications Two Versions Available: Standard Detector and Ultra Detector STANDARD
More informationPSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER
KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER KL4000 Series hybrid recorders realize simple and easy operation as analog recorders. Not only can each measured value be read from the custom
More informationInfrared Moisture Determination Balance FD-610. Operating Manual
Infrared Moisture Determination Balance FD-610 Operating Manual Infrared Moisture Determination Balance Safety Notes Improper use of the infrared moisture tester in violation of the following safety notes
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationClass 1 laser beam sensor safe for your eyes
1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11
More informationClass 1 laser beam sensor safe for your eyes
13 Sensor SERIES Related Information General terms and conditions... F-17 About laser beam... P.13~ Sensor selection guide... P.967~ General precautions... P.1 PHOTO PHOTO Conforming to EMC Directive Conforming
More informationD-TEK -MS Vehicle Loop Detector. Operating Instructions
D-TEK -MS Vehicle Loop Detector Operating Instructions We have designed the new D-TEK vehicle loop detector with the following objectives in mind: 1. Compact package to allow easy installation into small
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationTrueAlarm ES Analog Sensing
TrueAlarm ES Analog Sensing UL, ULC, CSFM Listed; FM Approved* Features TrueAlarm addressable sensor base with 520 Hz sounder TrueAlarm sensor bases with 520 Hz tone require a TrueAlarm photoelectric,
More informationUser s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31
User s Manual Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30 Fuji Electric Co., Ltd. TN514629i 1/31 Introduction Thank you for purchasing the Electronic Personal Dosimeter NRF30 (Hereinafter described
More informationMR SERIES CARD LOGGERS
MR SERIES CARD LOGGERS SPLASH PROOF TYPE TEMPERATURE CARD LOGGER MODEL MR5300 Model MR5300 is a small size and lightweight card logger capable to store up to 6000 temperature data, and is washable (IP64
More informationMVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions
MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC Operating Instructions We have designed the new MVP-D-TEK vehicle loop detector with the following objectives in mind: 1. Compact package to allow
More informationCORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation
CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD Corona Corporation This instruction manual contains important information for safe use of this device. Keep this instruction manual
More informationE N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.
E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0E FL0E FL0E mm mm 0 mm DESCRIPTION The LT FL0 Series is part of the Fire Alarm Aspiration
More informationENGINEERED PARKING SYSTEMS MODEL 3416D
ENGINEERED PARKING SYSTEMS MODEL 3416D Vehicle Loop Detector Operating Instructions ENGINEERED PARKING SYSTEMS 25010 AVENUE TIBBITTS VALENCIA, CA 91355 (661) 294-0778, (800) 377-4636 www.epsinfo.com We
More informationPower Supply Display Module PSDM. Installation and Operation Manual
Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious
More informationLifeAlarm Fire Alarm Controls
UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity
More informationTECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel
CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry
More informationCopying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.
Installation manual detector and controller Code no. 20711062 Page 1/30 CONTENTS Controller... 2 Function of the Relays... 2 Gas Detectors... 2 Cabling... 4 Mechanical Installation of the gas detectors...
More informationInstruction Manual. Digital Recorder. Model SDR-304. Make sure all the accessories are supplied together. Introduction Connection. Operation.
Digital Recorder Instruction Manual Model SDR-304 Function r - ACCESS ALARM REMOTE WARNING TIMER MENU ENTER SHIFT Setting Others Make sure all the accessories are supplied together. AC120V NTSC CAUTION
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors
More informationTECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2
FEATURES: Closed Loop Design (Class A Wiring) Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305-2
DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationQA16 Addressable System
QA16 Addressable System Operating Manual HORING LIH INDUSTRIAL CO., LTD. www.horinglih.com QA16 System Characteristics Each loop can connect with 250 devices. Easy system programming through PC to panel.
More informationTrueAlarm Analog Sensing
TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable
More informationControllers. Centralization of Access Control Devices Made Easy. Installer Guide
Controllers Centralization of Access Control Devices Made Easy Installer Guide CONTENTS 1 INTRODUCTION 3 The Overview of Hardware 5 The Overview of Installation & Communications 7 Installations with door
More informationRemote alarm indicator and test combination MK2430
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC
More informationThermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E
Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E Thermo Fisher Scientific Messtechnik GmbH Frauenauracher Straße 96 91056 Erlangen Germany www.thermo.com info.rmp.erlangen@thermofisher.com
More informationLD-5000 REFRIGERANT LEAK DETECTOR
LD-5000 REFRIGERANT LEAK DETECTOR www.jbind.com TM PRODUCT OVERVIEW JB Industries is proud to unveil the new, revolutionary LD-5000 PROWLER refrigerant gas leak detector. Using our new proprietary JB Industries
More informationAdvanced Ultraviolet Burner Controller
No. CP-SS-7E Advanced Ultraviolet Burner Controller Model AUR300C/AUR30C Overview The AUR300C Advanced Ultraviolet Burner Controller and AUR30C Advanced Ultraviolet Burner Controller with Communication
More informationTrueAlarm Analog Sensing
UL, ULC Approved* TrueAlarm Analog Sensing TrueAlarm Analog Sensors Photoelectric and Heat; Standard Bases and Accessories Features TrueAlarm analog sensing provides: Digital transmission of analog sensor
More informationThermoelectric Bath. Series HEB
Peltier-Type Thermoelectric Bath Accurately controls the temperature of liquid in the bath. Temperature stability: ±0.018 F Temperature distribution: ±0.036 F in the bath Environmentally friendly and refrigerant-free
More informationACCURATE ELECTRONICS INC
ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationFlexible Air-sampling Smoke Detection
Flexible Air-sampling Smoke Detection BY Technology Pioneers in Highsensitivity Air-sampling Smoke Detection Systems Providing Solutions Beyond Traditional Smoke and Fire Detection Hochiki, a world-leader
More informationSiemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation
Sinteso Cerberus PRO FDA241, FDA221 ASD Aspirating smoke detector Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Patented technology Early
More informationRF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1
RF SCOUT PLUS INSTRUCTION MANUAL Dielectric, LLC 22 Tower Rd. Raymond, ME 04071 Phone: 800.341.9678 www.dielectric.com 21 January 2015, Rev B 1 WARNING Powering RF sensors above +30dBm (1W) will cause
More informationFLAME SENSOR FS-2000E
FLAME SENSOR FS-2000E We appreciate your purchase of a TAKEX flame sensor. Please read this instruction manual carefully for correct and effective use. This sensor is designed to detect flames and to initiate
More informationP2267 NETWORK INTERFACE
P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationPioneer-R16 Gas Monitor Operator s Manual
Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas
More informationTrueAlert Addressable Notification
UL, ULC Approved* TrueAlert Addressable Notification 4009 IDNAC Repeater; Power and Distance Extender Features IDNAC Repeaters provide enhanced power delivery to TrueAlert/ TrueAlert ES addressable notification
More informationACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX
Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800
More informationBSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.
637 PHOTO PHOTO Flameproof Type Curtain Type 4 General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Sensor selection guide... P.497~ General precautions... P.1458~ Conforming
More informationThermoelectric Bath. Series HEB
Peltier-Type Thermoelectric Bath Series HEB Accurately controls the temperature of liquid in the bath. Temperature stability: ±0.018 F Temperature distribution: ±0.036 F in the bath Environmentally friendly
More informationHOST SERVER CRITICAL INFRASTRUCTURE & ENVIRONMENTAL MONITORING SYSTEM DATA CENTER PLANT BASE STATION. Generator Fuel Level. Battery Monitoring
CRITICAL INFRASTRUCTURE & ENVIRONMENTAL MONITORING SYSTEM HOST SERVER Generator Fuel Level Temperature & Humidity Precision Air Conditioning Battery Monitoring Harmful Gas & Particle Detection Water Leak
More informationInstallation Guide: PowerAire Quad
INSTALLATION GUIDE FOR POWERAIRE QUAD QUAD-FAN ASSIST Tel (410)799-4200 1 of 14 INTRODUCTION Tate s Variable Speed Fan Assist device provides the user with unparalleled local control and reliability of
More informationThis wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control
File: S8485 Wiring Diagram This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control Panel. The operation of this product is intended for indoor
More informationVD 53 - Vacuum drying oven for non-flammable solvents
Vacuum drying ovens VD 53 - Vacuum drying oven for non-flammable solvents The VD series offers safe drying with homogenous temperature distribution, thanks to its APT.line air jacket system. ptimum heat
More informationSpecification/ Data Sheet
Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)
More informationBuzzer Unit. TAN-5000 Series. Operating Manual
PT1E-1040 Buzzer Unit TAN-5000 Series Operating Manual Request for the Customers Read and understand this operating manual before using the buzzer unit. Use the buzzer unit in accordance with the operating
More informationSystem Accessories, LCD Annunciators
System Accessories, LCD Annunciators UL, ULC Approved* A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Features Fig 1: A4606-9202 LCD Annunciator with Red Trim Fig
More informationCOMMUNICATOR ET08 / ET081
COMMUNICATOR ET08 / ET081 User Manual v1.2 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: GSM communicator ET08 / ET081 (further
More informationT125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance
T125-E Electric Fan Coil Thermostat Product Bulletin New Generation T125 Electric Fan Coil Thermostats are designed to control heating, cooling, or air conditioning unit in Commercial, Industrial and Residential
More informationModel ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends
Model ATD-36750 Refrigerant Gas Leak Detector Detects all CFC, HFC, HCFC, HFO Refrigerants including blends User Manual Design certified by ASCI and Intertek to meet SAE J2791, J2913 & EN14624 INTRODUCTION
More informationINSTRUCTION MANUAL RM AM/FM Digital Alarm Clock Radio
INSTRUCTION MANUAL RM-6090 AM/FM Digital Alarm Clock Radio PRECAUTIONS CAUTION: THE APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING. NO OB- JECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display
More informationPart 3 Troubleshooting
Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions
More informationCIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR
CIRRUS PRO ASPIRATING FIRE DETECTOR User Manual and Responsibilities Protec Fire Detection (Export) Ltd, Protec House, Churchill Way, Nelson, Lancashire. BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44
More informationMetasys Integrator Compu-Aire Application
Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0496 APPLICATION NOTE Metasys Integrator Compu-Aire Application lntroduction Page 3 Application Details
More informationIR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining
IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining FEATURES * Configured for carbon dioxide (IR11BD, IR21BD), hydrocarbons (,,, ) or acetylene
More informationMulti-Point Peripherals
UL, ULC Approved* Multi-Point Peripherals TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features Fig 1: TrueAlarm CO Sensor Base with Sounder (shown with
More informationLifeAlarm Fire Alarm Control Panels
LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient
More informationELECTRONIC FLAME SUPERVISION MULTI-BURNER
MULTI-BURNER MODEL: SENS-A-FLAME II Revision: 0 7112 DESCRIPTION Model 7112 Sens-A-Flame II is a second generation solid-state programmable combustion safeguard for supervising multiple burner ovens, furnaces,
More informationRIELLO 40 GS/M SERIES
The Riello 40 GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed to respond to any request of gas burners for hot air generator according to EN 1020.
More informationSpecifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure
DUST DENSITY METER (DDM-2001) Specifications Table of contents 1:Outline 2:Specification 3:Composition 4:Instruments outside figure 1) Main body control box 2) Detector 3) Optical fiber cable 4) Purge
More informationTrueAlarm Analog Sensing
TrueAlarm Analog Sensing UL, ULC Listed, CSFM Approved* Features Air aspiration duct smoke detection** system provides remote sensor location for ducts with difficult service access: Available as either
More informationPSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER
AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER AL4000 series is a hybrid recorder which employs bright and clear, easy to view LCD display. Measuring value display is prepared as 1 point
More informationFire Alarm System Accessories
UL, ULC Approved* Fire Alarm System Accessories Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer isolated barrier
More informationOIL FILM DETECTOR (Long-distance correspondence Version)
OIL FILM DETECTOR (Long-distance correspondence Version) ODL-6A The Model ODL-6A monitors a water surface for the presence of an oil film floating on the surface. The instrument projects a laser beam onto
More informationM004 combustible gas module
M004 combustible gas module M004 combustible gas module Introduction: M004 gas module can change the concentration of combustible gas in the air into digital signal output. It uses three-line system 4-20mA
More informationFrequently asked questions: Intelligent Transmitter Series
Frequently asked questions: Intelligent Transmitter Series The Wilcoxon family of Intelligent Transmitters, relay alarms, and communication modules can be used to implement low-cost online vibration monitoring
More informationRACK MONITORING SYSTEM - RAMOS Ultra
CONTEG DATA SHEET version: 9-05-0 COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM marketing@dafnia.com www.dafnia.com ABU DHABI UAE +97 55575 DUBAI JAFZA +97 4 5995 +97 4 8840 MUSCAT DOHA OMAN +968 4 75005
More informationMBCE-110/230UV Flame Sensor Module
MBCE-1002 FEBRUARY 3, 2017 MBCE-110/230UV Flame Sensor Module DESCRIPTION The MBCE-110/230UV modules provide visual indication and electrical outputs that signal the user regarding flame presence in a
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305
DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationFire Control/Communicator
Operation and Installation Manual Fire Control/Communicator 1 2 3 4 5 12V AC,20V A, 60Hz or +24V DC 12V AC, 20V A, 60Hz or -24V DC EARTH GND BATTERY - BATTERY + 6 INITIATING A1-7 INITIATING A2-8 INITIATING
More informationRAM-216. Remote Multiplex Annunciator Panel. Wiring & Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE
Advanced Life Safety Solutions RAM-216 Remote Multiplex Annunciator Panel A.C. ON COMMON TROUBLE SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE LAMP TEST SYSTEM RESET Wiring & Installation Manual LT-658
More informationDual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual
We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationGeneral Specifications
General Specifications Model OX400 Low Concentration Zirconia Oxygen Analyzer The OX400 is a highly accurate and reliable low-concentration zirconia oxygen analyzer that is capable of measuring a wide
More informationXLH210: controller for gas leak detectors
pag. 1 / 7 XLH210: controller for gas leak detectors Dixell introduces the new digital controllers designed to be combined with 4 20mA gas leak detectors. XLH210 is a microprocessor based controller, designed
More informationJK e-solutions ApS FS12. Control and Monitoring system for Fixed Aerosol Fire Extinguishing Systems. Installation and Service Manual R11
FS12 Control and Monitoring system for Fixed Aerosol Fire Extinguishing Systems Installation and Service Manual R11 Main-unit SW V1.02.04 and later Table of Contents 1 Preface... 4 1.1 Purpose... 4 1.2
More informationABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements
Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More informationThe system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.
0BThe System The Security Management System should be capable of Controlling and Monitoring Access through the doors, Monitor and control Inputs and Outputs, include an Integrated Video Badging, Integrate
More informationUSER MANUAL FOR OPERATING SYSTEM
P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177
More informationAdded cooling capacity of 140 W and 320 W (watercooled), (air-cooled). Thermo-con. controlled to a constant temperature
Peltier-Type Chiller Thermo-con Air-cooled Water-cooled Series Can precisely control the temperature of a heat source or process fluid. Precisely control the temperature of the circulating fluid by using
More informationQ-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air
Document No. 155-755 Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Description Features Application The Q-Series Relative Humidity and
More informationDLC Instruction Manual. Light Curing Machine MODEL. Table of Contents
Light Curing Machine Table of Contents Precautions for Electrical >>>>>>>>>>> 1 Equipment in Use Precautions >>>>>>>>>>>>>>>>>>>> 2 Recommended Procedure when >>>>> 4 Opening Product Packaging Part Names
More informationPEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K
PEGAsys Multi-Loop Intelligent Suppression Control System A UTC Fire & Security Company Effective: March 2007 K-76-028 FEATURES UL Listed CSFM Approved MEA Approved Peer-to-Peer Networking (to 32 nodes)
More informationOVEN INDUSTRIES, INC.
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and
More informationHigh Precision Digital Rain Gauge with Indoor Temperature and Humidity
High Precision Digital Rain Gauge with Indoor Temperature and Humidity Contents 1. Introduction... 2 2. Get Started... 2 2.1 Parts List... 2 2.2 Recommend Tools... 3 2.3 Installation... 3 2.4 Mount outdoor
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More information