C E IL IN G W A L L SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Similar documents
CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CASSETTE type INVERTER MULTI AIR CONDITIONER

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

FLOOR CONSOLE / UNDER CEILING DUAL type

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

ASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

ASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz)

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

WALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type )

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

AUXG18LRLB AUXG24LRLB UTG-UKYA-W AOYG18LBCA AOYG24LBCA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) CONTENTS

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

IMPORTANT SAFETY NOTICE

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

Digital Inverter 4 series 8 & 10HP

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)

CMS1402 SERVICE PARTS

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

Fast Track Troubleshooting

Compact 4-way Cassette ( ) Type

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

CME1856W Service Parts

CME1856W Service Parts

DESIGN & TECHNICAL MANUAL

TSC & TSC-M Proofer/Oven

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

Кондиционеры Mitsubishi Heavy

Fast Track Troubleshooting

DESIGN & TECHNICAL MANUAL

Parts and Service Manual

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

4. Disassembly and Reassembly

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

HID312, HID525 and HID540 Service Parts

AUT O HE AT COOL DRY FAN SPEE D AIR SW ING OFF/ON MODE TEMP AIR SW ING POWERFUL/ QUIET TIMER ON SET OFF CANCEL SET CHECK CLOCK RESET WARNING

Fast Track Troubleshooting

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

EDUS Heat Pump - D-Series

SERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

DESIGN & TECHNICAL MANUAL

CU-S9NKV-7 CU-S12NKV-7 CU-S18NKV-7 CU-S22NKV-7 CS-S9NKV-7 CS-S12NKV-7 CS-S18NKV-7 CS-S22NKV-7 WARNING

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*R07LGC AO*R09LGC AO*R12LGC AO*R14LGC

RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E

Fast Track Troubleshooting

Global-Tek (Singapore) Pte Ltd

6868 Ardmore Street Houston, Texas Toll Free Phone Fax

CU-RE18RKE CU-RE24RKE CS-RE18RKEW CS-RE24RKEW. Destination Europe L.America Turkey WARNING

DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU / h 11,900BTU / h 17,500BTU / h 24,200BTU / h

Fast Track Troubleshooting

CU1526, CU2026, CU3030 Service Parts

Ductless Split Air Conditioner

Fast Track Troubleshooting

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

EXPLODED VIEWS & PARTS LISTS

Service Parts for models UF424 and UN324

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

TECHNICAL DATA & SERVICE MANUAL

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

Parts List. Low-Profile Modular Crescent Cuber. Models KML-325MAJ KML-325MWJ. hoshizakiamerica.com

Transcription:

SPLIT TYPE ROOM AIR CONDITIONER C E IL IN G W A L L t y pe Models Indoor unit Outdoor unit AWY24LBAJ AOY24LMAL AOY30LMAL CONTENTS SPECIFICATIONS................................ 1 OUTLINE AND DIMENSIONS.......................... 3 REFRIGERANT SYSTEM DIAGRAM.................... 4 ERROR CONTENTS.................................. 5 CIRCUIT DIAGRAM............................... 6 INDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM.. 7 OUTDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM 8 DISASSEMBLY ILLUSTRATION....................... 12 PARTS LIST....................................... 23 STANDARD ACCESSORIES........................... 25

SPECIFICATIONS TYPE INDOOR UNIT OUTDOOR UNIT COOL & HEAT AWY24LBAJ AOY24LMAL COOL & HEAT AOY30LMAL COOLING CAPACITY (kw) 6.8 8.0 HEATING CAPACITY (kw) 7.0 8.5 ELECTRICAL DATA POWER SOURCE (V) 230 FREQUENCY (Hz) 50 RUNNING CURRENT INPUT WATTS (A) (kw) COOLING 9.3 13.3 HEATING 8.5 12.3 COOLING 2.12 3.04 HEATING 1.94 2.81 E.E.R. (kw/kw) COOLING 3.21 2.68 HEATING 3.61 3.02 MOISTURE REMOVAL ( /hr) 3.0 3.6 AIR CIRCULATION-Hi (m 3 /hr) 1,050 1,050 COMPRESSOR TYPE DISCRIMINATION REFRIGERANT R410A (g) Hermetic type, Inverter, 4 poles, Three phase, DC motor, Twin Rotary TNB220FPCM9 1,850 FAN MOTOR POWER SOURCE (V) 230 DISCRIMINATION MFD-36JO HI-SPEED (r.p.m.) 1,450 INDOOR UNIT MED-SPEED (r.p.m.) 1,280 LO-SPEED QUIET (r.p.m.) (r.p.m.) 1,180 1,080 OUTDOOR UNIT DISCRIMINATION (r.p.m.) MFB-30NTAT 730 DIMENSIONS INDOOR UNIT H x W x D (mm) 270 x 1,150 x 285 OUTDOOR UNIT H x W x D (mm) 900 x 900 x 350 WEIGHT INDOOR UNIT GROSS / NET (kg) 20 / 16 OUTDOOR UNIT GROSS / NET (kg) 78 / 70 2004.11.12 1

TYPE COOL & HEAT COOL & HEAT INDOOR UNIT OUTDOOR UNIT AWY24LBAJ AOY24LMAL AOY30LMAL NOISE LEVEL HI-SPEED (db) 47 INDOOR UNIT MED-SPEED LO-SPEED (db) (db) 43 40 QUIET-SPEED (db) 37 OUTDOOR UNIT (db) 52 REFRIGERANT CHARGE (R410A) PIPE LENGTH FULL CHARGE AMOUNT ADDITIONAL REFRIGERANT 10 m (33 ft.) 15 m (49 ft.) 20 m (66 ft.) 25 m (82 ft.) 1,850 g (65.1 oz) 2,100 g (73.9 oz) 2,350 g (82.7 oz) 2,600 g (91.7 oz) 50 g / m (1.76 oz / 3.3 ft.) (over 10 m) 2004.11.12 2

OUTLINE AND DIMENSIONS Models : AWY24LBAJ Unit : mm Models : AOY24LMAL AOY30LMAL 48 804 48 11 373 333 ~ 352 350 900 30 900 Packed Valve (Liquid) 9.52 Packed Valve (Gas) 15.88 2004.07.22 3

REFRIGERANT SYSTEM DIAGRAM Models : AWY24LBAJ / AOY24LMAL / AOT30LMAL OUTDOOR UNIT COMPRESSOR HEAT COOL 4-WAY VALVE HEAT EXCHANGER CAPILLARY TUBE HEAT EXCHANGER RECEIVER ACCUMULATOR EXPANSION VALVE STRAINER 3-WAY VALVE 2-WAY VALVE INDOOR UNIT HEAT EXCHANGER 2004.06.16 4

ERROR CONTENTS The OPERATION, TIMER and SWING lamps operate as follows according to the error contents. Error contents Error display OPERATION TIMER SWING () (GREEN) (ORANGE) Indoor unit circuit board error Indoor unit room temperature sensor wire opened Indoor unit room temperature sensor wire short circuited Indoor unit piping sensor wire opened Indoor unit piping sensor short circuited Serial error Outdoor unit circuit board error or miswiring between outdoor unit and indoor unit Indoor unit fan error 2 times 2 times 3 times 3 times 5 times 5 times 6 times Outdoor unit piping sensor Outdoor unit outdoor temperature sensor error Outdoor unit discharge temperature sensor error Outdoor unit compressor temperature sensor error IPM error Current transformer error Active filter module error Compressor location error Outdoor fan motor error 3 times 4 times 5 times 9 times 10 times 11 times 12 times 13 times 14 times : Fast flashing : Slow flashing : Off DIP switch DIP-SW 1 2 3 Current (Max.) Model OFF OFF OFF 16.5A AOY30LMAL ON OFF OFF 14.5A AOY24LMAL OFF ON OFF 12.0A ON ON OFF 9.5A 2004.07.22 5

CIRCUIT DIAGRAM Models : AWY24LBAJ / AOY24LMAL / AOY30LMAL OUTDOOR UNIT INDOOR UNIT TO POWER SOURCE 2004.07.23 6

SWITCHING INDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM Models : AWY24LBAJ CONTROLLER PCB ASSEMBLY (MAIN PCB) AWY24LBAJ : EZ-0021HHSE-C : EZ-0021GHSE-C ROOM TEMPERATURE THERMISTOR HEAT EXCHANGER THERMISTOR OPERATE INDICATOR PCB MANUAL AUTO SWITCH Jumper wire configurations Switch Function ON/Linked OFF/Open SWITCHING SWITCHING SWITCHING JM1 High ceiling (See table 5) standard High Ceiling 1 JM2 / JM3 Custom code (See table 2) JM4 Auto restart enable disable JM5 / JM6 Heating compensation (See table 1) CORRECTION CORRECTION Table 1 ON / ON 4 Table 2 ON / ON A ON / OFF -2 ON / OFF B OFF / ON 0 OFF / ON C OFF / OFF 2 OFF / OFF D 2004.11.12 7

OUTDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM Models : AOY24LMAL AOY30LMAL INVERTER ASSEMBLY POWER SOURCE AC230V POWER SUPPLY PCB ASSEMBLY ( B-K01FL-05 ) EZ-001AHUE-P L N W201 AWG14 F201 TLC25A-250V B AWG14 AWG20 W1 W31 B L B W8 ORANGE B W9 ORANGE AWG18 ORANGE AWG18 ORANGE POSISTOR ZPR0YCE 400A300 3 AWG14 W2 CHOKE COIL L=0.3MH 30A TO INDOOR UNIT L N 3 FAN MOTOR-1 AWG20 AWG16 GREEN FM1 W33 B C211 FAN CAPACITOR-1 450V 4uF N W3 B EARTH GREEN W23 B W22 B AWG20 AWG20 W202 AWG20 SERIAL AWG20 AWG14 BROWN 1 3 TM2 TM1 CN34 B2P3-VH-B-Y W102 B 1 2 3 4 W103 B 5 6 7 CN11 B4P7-VH-B BROWN W10 TM101 VIOLET AWG14 BROWN W105 BROWN VIOLET W20 W21 UL1007 AWG20 1 2 CN42 B2PB-XAYK-1-A TM102 TM103 W203 AWG14 W204 AWG14 AWG12 L1 I C 414 AWG12 L2 P - N1 N2 I O ACTPM SACT32010A 1 2 3 4 5 6 W205 AWG14 W206 AWG14 VIOLET EMI FILTER TFT-152613N 2T BROWN ORANGE UL1007 AWG24 TM104 TM105 1 2 3 4 BROWN ORANGE W27 B W25 B CN407 B4B-XASK-1-A 1 AWG20 CN35 3 B2P3-VH-B-M GREEN TM110 TM107 CN15 B6B-XASK-1-A CN16 B7B-XASK-1-A W207 AWG14 W208 AWG14 6 5 ORANGE 4 3 2 BROWN 1 UL1007 AWG24 GRAY VIOLET GREEN UL1007 AWG24 P N 7 6 5 4 3 2 1 CN302 CN302 TR PCB ASSEMBLY ( B-K02CJ-01 ) EZ-001AHUE-TR U V W AWG16 1 1 3 3 2 2 C M COMPRESSOR 4-WAY VALVE EXPANSION VALVE M BROWN ORANGE 1 2 3 1 2 3 4 5 6 CN30 179844-1 CN27 B6B-XARK-1-A CONTROLLER PCB ASSEMBLY ( B-K01FK-02 ) AOY24LMAL : EZ-003PHUE-C AOY30LMAL : EZ-003RHUE-C CN14 B9B-XASK-1-A BROWN ORANGE GREEN VIOLET GRAY UL1007 AWG24 1 2 3 4 5 6 7 8 10 CN301 DISCHARGE TEMPERATURE THERMISTOR PIPE TEMPERATURE THERMISTOR OUTDOOR TEMPERATURE THERMISTOR -0-0 -0 BROWN BROWN 1 2 1 2 1 2 CN21 B2B-XH-AM CN22 B2B-XH-AM CN23 B2B-XAEK-1-A 2004.07.22 8

Models : AOY24LMAL AOY30LMAL AC VOLT I N FAN CAPACITOR 1 FAN MOTOR 1 FAN CAPACITOR 2 FAN MOTOR 2 ELECTRIC VALVE 4-WAY VALVE CRANK CASE HEATER PRESSURE SWITCH 2 PRESSURE SWITCH 1 EXPANSION VALVE DISCHARGE TEMPERATURE PIPE TEMPERATURE OUTDOOR TEMPERATURE HEAT SINK TEMPERATURE COMP. TEMPERATURE SERIAL CN34 B2P3-VH-B-Y N L CN11 B4P7-VH-B CN12 B4P7-VH-B-R CN31 B2P3-VH-B CN30 179844-1 CN33 B2P3-VH-B-C CN36 B2B-XASK-1-A CN37 B2B-XARK-1-A CN27 B6B-XARK-1-A CN21 B2B-XH-AM CN22 B2B-XH-AM CN23 B2B-XAEK-1-A CN25 B2B-XAKK-1-A CN26 B2B-XAMK-1-A GREEN TM1 W103 W102 W101 W104 B B B B CR3 RE1202 CR5 RE1202 CR6 RE1202 R90 2.2K C70 0.01 L202 BL02Rn1 24V 18 K11 G5S-1 K12 G5S-1 C71 0.01 R97 10 <1/2W> L201 BL02Rn1 R63 6.65K (1%) R65 56K (1%) R67 38.3K (1%) R98 56K (1%) R100 56K (1%) R94 10 <1/2W> R95 10 <1/2W> R96 10 <1/2W> R62 10K R64 10K R66 10K R99 10K R101 10K CR1 RE1202 12V 12V 14 12V 12V 12V R91 2.2K R92 1.0K R93 1.0K C66 1.0 C67 1.0 C65 1.0 C75 1.0 C76 1.0 CN42 B2B-XAYK-1-A POWER RELAY CONTROL CR2 RE1202 12V C72 0.01 O1 O2 O3 O4 HYIC1 HU2001 BROWN W105 TM2 12V CT1 CT-1B 10 5 4 3 2 1 12V K13 G5N-1A K14 G5N-1A K15 G5N-1A K17 G5N-1A K18 G5N-1A GND1 COM1 GND3 GND4 I 1 I 2 I 3 I 4 GND2 COM2 NC1 NC2 IC4 TD62064 24V 12V D28 TLR124 <> R43 2.2K IC3-4 M54523 IC3-3 M54523 IC3-2 M54523 IC3-1 M54523 IC5-1 M54523 IC5-2 M54523 IC5-5 M54523 IC5-4 M54523 IC5-6 M54523 R51 4.7K D60 DA226U C60 <PJ> 220/16V R60 1.0K (1%) JM51 R50 10K R52 1.0K C35 0.01 C40 0.1 VR1 B2K R55 1.0K R61 3.74K (1%) Q51 2SC2412K <BQ> R56 27K C51 0.022 IC1 MB90462-125 P63 P62 P46 P12 P50 P37 P36 P40 MD2 P11 P26 P02 P03 P04 P05 P06 P07 P10 C P20 P21 P22 P23 P57 P56 P55 P54 P52 P53 P51 X0 X1 CONTROLLER PCB ASSEMBLY AOY24LMAL : EZ-003PHUE-C AOY30LMAL : EZ-003RHUE-C R68 22K C53 0.022 X1 8.00MHz <EF0EC> C64 0.1 VCC AVCC P00 P01 P17 P13 P14 P15 P16 AVR P24 P25 P30 P31 P32 P33 P34 P35 P60 P61 MD0 MD1 P44 P43 P42 P41 P45 RSTX P27 AGND GND GND R403 10K R407 10K C19 C18 0.1 x 2 DC VOLT IN CN35 B2P3-VH-B-M GREEN IC401 PS2561-1 IC404 PS2561-1 C20 <PS> 4.7/50V R608 10K C36 0.01 - R19 10K R33 47K R40 1.0K C33 0.01 A 18V 18V R436 3.3K 8 <1/4W> - IC400-1 18V upc393 R442 3.3K <1/4W> - IC400-2 upc393 4 A IC201 BR93LC46 CS SK D1 NC VCC D0 NC GND JM207 R201 220K <2W> C17 0.01 R72 1.0K C16 4.7/50V <PS> IC6 BD4742G SUB NC 10K x 7 R11 R12 C409 10/2 <PS> A A C412 0.1 R140 2.4 <1/2W> A R13 R14 R205 10K R6 100K <2W> R1 100K <2W> Q1 2SC4236 R15 18V R402 3.3K <1/4W> R141 2.4 <1/2W> D1 M1FL20 C91 0.01 R16 D402 RD3.3ES <B2> A C411 R435 1.0K 0.01 C414 0.01 R441 1.0K D10 RD5.6ES <B2> R114 27K C95 1000P <CH> R17 R73 82K VCC VOUT GND R113 1.0K Q91 2SC2412K <BQ> O R400 180K <RN-1/2W> R440 180K <RN-1/2W> R406 2.87K (1%) R401 2.94K (1%) A R2 1.0K <RS-3W> R3 100 <1W> C2 0.047 D2 <ECQB> M1FL20 18V R4 330 <1/4W> 1 IC13 PS8602 5 7 4 D 8 I G IC2 PST600D SW1 JM105 JM104 JM103 JM106 C3 <PJ> 100/16V C1 220P <BN> R103 4.7K - R74 10K R102 1.6K <1/4W> 6 3 2 1 IC11 upc393 CORRENT CHANGING 1 CORRENT CHANGING 2 CONSTRUCTION CHECK MODEL CHANGING 2 MODEL CHANGING 1 MODEL CHANGING 0 TEST JUMPER R104 195K <RN-1/2W> R106 195K <RN-1/2W> R105 2.49K (1%) R108 2.87K (1%) D C418 <PS> 10/3 O G I A IC407 upc24m18 R75 10K D401 M1FL20 C406 <PJ> 220/50V JM114 JM113 JM115 JM116 R76 10K FH3 PFC5000-0502 F2 BET 3.15A FH4 PFC5000-0502 T1 IVP3300-08C C89 470P <CH> R115 1.0K R77 10K DA226U x 2 D81 D82 C86 C87 2200P 470P <CH> <CH> D R78 10K D7 M1FL20 R79 10K JM111 R605 22K D4 M1FL20 D5 M1FL20 D6 M1FL20 D3 M1FL20 D11 M1FL20 D8 M1FL20 JM112 C88 0.1 R604 10K R404 510 Q401 DTC114EKA R8 18K C10 <PJ> 220/50V R5 10K C4 <PJ> 470/2 C5 <PJ> 220/16V 1 3.3V R109 1.6K <1/4W> D12 <B2> RD3.3ES R21 10K I G O IC8 TA7805 R112 R110 R603 10K R20 10K C415 0.01 IC402 18V 18V PS2561-1 A 24V 12V R80 330 R81 330 R82 330 R83 330 R84 330 R85 330 R602 10K R437 270 VR2 B2K 195K (1%) <RN-1/2W> x 6 R111 R86 R87 2.94K (1%) R107 680 (1%) C6 <PJ> 100/16V C8 0.022 R89 R88 R601 10K C413 0.01 R438 270 A C13 <PJ> 100/3 C12 <PJ> 100/3 C11 <PJ> 100/3 1 C14 <PJ> 220/3 D C34 0.033 A CN407 B4B-XASK-1-A ACTPM CONTROL CN16 B7B-XASK-1-A IPM POWER SUPPLY2 CN15 B6B-XASK-1-A IPM POWER SUPPLY1 CN14 B9B-XASK-1-A IPM DRIVING SIGNAL CN601 B10B-PASK-1 TAUX TTXD TRXD TMODE TAUX3 TCK / TRES / TICS FLASH 2004.07.22 9

Models : AOY24LMAL AOY30LMAL POWER SUPPLY PCB ASSEMBLY EZ-001AHUE-P TM101 W7 W10 AWG14 BROWN MAIN PCB W8 B AWG18 ORANGE POSISTOR L AC220-240V 50Hz N MULTI CONTROLLER AWG16 INDOOR UNIT AWG16 POWER SOURCE AWG14 MULTI CONTROLLER AWG16 INDOOR UNIT AWG16 POWER SOURCE AWG14 EARTH AWG16 GREEN W2 W32 B W31 B W1 VA101 470V <TNR> W34 B W3 B W33 B VA102 470V <TNR> JM1 C101 1.0 <LE> AWG20 SA100 RA-302M C102 0.033 <YE> C103 0.033 <YE> L1 RCH3818-015PF05 C104 0.033 <YE> C105 0.033 <YE> C106 1.0 <LE> L2 RCH3818-015PF05 C107 1.0 <LE> C108 0.015 <YE> C109 0.015 <YE> L3 n200500k C110 1.0 <LE> R200 ZPR0RCH400 C111 3.3 <ET> K101 G4A-1A -PE-PS C112 1.0 <LE> D101 D25XB60 - W9 B W5 W6 C113 0.1 <HCP> AWG18 ORANGE POSISTOR AWG14 ORANGE DIODE BRIDGE AC INPUT AWG14 GRAY DIODE BRIDGE AC INPUT TM102 ACTPM W16 AWG14 AWG14 W17 TM103 ACTPM- ACTPM P AWG14 ACTPM N1 AWG14 PURPLE TM104 W11 W12 TM105 R201 220K <2W> F1 25A C201 C202 C203 C114 500/ 500/ 500/ 0.1 450V 450V 450V <HCP> W26 W14 W15 AWG14 TM110 TM108 AWG14 TM107 AWG14 IPM P IPM P IPM N AC OUTPUT L N AWG20 AWG20 W22 B W23 B FH3 VA103 470V <TNR> F4 5A <BET> FH4 POWER RELAY CONTROL UL1007 AWG20 PURPLE UL1007 AWG20 W20 B W21 B DC OUTPUT PLUS POLARITY AWG20 MINUS POLARITY AWG20 PLUS POLARITY AWG20 W27 B W25 B W24 B 2004.06.16 10

Models : AOY24LMAL AOY30LMAL TR PCB ASSEMBLY EZ-001AHUE-TR CN302 B YEL IPM POWER SUPPLY ORG BRN UL1007 AWG24 P4 L=450 C301 47/3 <PJ> C302 47/3 <PJ> CN303 B GRY IPM POWER SUPPLY UL1007 AWG24 07 / 07 172520 XAP-07V-1 CN301 PUR BLU GRN BRN B IC307 PS2561-1-V H IC301 R301 560 PS2561-1-V H <1/4W> C304 100/3 <PJ> C303 47/3 <PJ> VUP1 UP VUPC VVP1 VP VVPC VWP1 WP VWPC UN VN WN F0 VN1 VNC P U V W N P U V W N ORG IC310 PM30CTJ060-38 IPM DRIVING SIGNAL YEL GRN BLU IC302 PS2561-1-V H R302 560 <1/4W> PUR GRY BLK UL1007 AWG24 10 / 09 172520 XAP-09V-1 IC303 PS2561-1-V H R303 560 <1/4W> IC304 PS2561-1-V H R304 560 <1/4W> IC305 PS2561-1-V H R305 560 <1/4W> IC306 PS2561-1-V H R306 560 <1/4W> 2004.06.16 11

DISASSEMBLY ILLUSTRATION Models : AWY24LBAJ 122 2004.06.16 12

Models : AWY24LBAJ 120 345 158 999 45 998 329 735 146 588 146-1 588-1 2004.07.23 13

Models : AWY24LBAJ 2004.06.16 14

Models : AWY24LBAJ 2004.06.16 15

Models : AWY24LBAJ 2004.06.16 16

Models : AWY24LBAJ 2004.06.16 17

Models : AWY24LBAJ 759-1 385 230 868 253-3 63 70-1 855 70-2 428 2004.06.16 18

Models : AWY24LBAJ 2004.11.12 19

Models : AOY24LMAL AOY30LMAL 7 183-1 949-1 2004.07.23 20

Models : AOY24LMAL AOY30LMAL 26-2 26-3 953 45-1 45-2 45-4 186 185-2 e 951 950 117-3 47 952 825-1 343-1 13-1 69-3 2004.07.23 21

Models : AOT24LMAL AOT30LMAL 824-4 32-11 32-8 32-9 824-3 381-3 32-10 32-7 823 381-2 967 887-1 2004.07.23 22

PARTS LIST INDOOR UNIT When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Ref. No. Description AWY24LBAJ Part No. Ord. Q'ty Ref. No. Description AWY24LBAJ Part No. Ord. Q'ty 8-2 Filter Frame 9367681013 9367681013 12 Base-B 9368216016 9368216016 32 Control Box 9367663002 9367663002 45 Bracket (Eva. ) Assy 9369317019 9369317019 62 Fan Motor-Inner 9601385028 9601385028 63 KIT (Front Cover) 9371132099 9371132099 63-1 Service Cover Assy 9368837013 9368837013 67 Rubber (Motor) 9367676002 9367676002 69 Louver 9367706013 9367706013 70-1 Hook (Cover)-L 9367675012 9367675012 321 Lower Flap 9367689019 9367689019 329 Coupling Pipe Assy 9370561005 9370561005 338 Motor Holder 9367798001 9367798001 345 KIT (FILTER GUIDE) 9371130019 9371130019 385 Indicator PCB Assy 9704368010 9704368010 407 Motor Link 9367696000 9367696000 407-2 Louver Rod 9367698004 9367698004 408 Louver Link 9367697007 9367697007 408-1 Louver Link-B 9368789008 9368789008 425 Earth Plate 9368017002 9368017002 70-2 Hook (Cover)-R 9367674015 9367674015 92 Link Arm 9367694006 9367694006 93 Filter 9367680016 9367680016 108 Base 9367683017 9367683017 108-1 Base Assy 9368829056 9368829049 108-2 Base-B Sub Assy 9368843014 9368843014 109 Terminal CVR 9368022006 9368022006 120 Eva. Sub Assy 9368832070 9368832056 122 Rub (Bearing) Assy 9368998004 9368998004 127 Drain Hose 9367695003 9367695003 428 Screw Cover 9367717019 9367717019 435 Louver Spring 9369030000 9369030000 514 Control Box Cover 9367664009 9367664009 522-1 Gear-A 9367691005 9367691005 522-2 Gear-B 9367692002 9367692002 557 Spring (Diffuser) 9368824006 9368824006 574-1 Eva. Support-R 9367684007 9367684007 574-2 KIT (Eva. Support-L) 9371129013 9371129013 588 Eva. Holder 9367711000 9367711000 588-1 Eva. Holder-B 9368783006 9368783006 146 Evaporator Assy 9371999012 9371999012 146-1 Evaporator Assy-B 9369124006 9369124006 158 Joint Pipe Assy 9369144004 9369144004 160 Drain Pan Assy 9368835026 9368835019 165 Motor Box 9367718009 9367718009 169 Cross Fan Assy 9367708000 9367708000 172 Pipe Bracket 9367844005 9367844005 172-3 KIT (Pipe Holder) 9371135014 9371135014 174-1 Fixing Plate 9367987009 9367987009 184-1 Thermo. Spring-A 313728262708 313728262708 627 Link 9367693009 9367693009 629 EMI Filter 0400056133 0400056133 735 Distributor Assy 9370560008 9370560008 743 Remote Control Holder 9305642014 9305642014 759-1 Intake Cover 9367678013 9367678013 764 Drain Cap 9367677009 9367677009 815-1 Terminal-3P 9306489090 9306489090 855 Display-F 9367672011 9367672011 868 PWB Holder (Display) 9371131016 9371131016 875 PCB Assy-Switch 9704370013 9704370013 199 Step Motor 9900020019 9900020019 230 Diffusion Sheet 9368006013 9368006013 234 Thermistor Assy-Room 9703299148 9703299148 235 Thermistor Assy-Pipe 9703297038 9703297038 236 Controller PCB Assy 9705066021 9705066014 240 Remote Control Unit 9371190112 9371190112 253-1 Wire With Connector 9704434012 9704434012 253-2 Wire With Connector 9704435019 9704435019 253-3 Wire With Connector 9704433015 9704433015 320 Upper Flap 9367688012 9367688012 945 Wire Holder 9368016005 9368016005 960 Diffuser Assy 9368840013 9368840013 963 Fan Guard 9368015008 9368015008 963-1 Fan Guard Holder 9367707003 9367707003 973 Gear Box 9367690008 9367690008 998 Bypass Pipe-B Assy 9372000014 9372000014 999 Bypass Pipe 9369126000 9369126000 2004.07.22 23

OUTDOOR UNIT When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Ref. No. Description AOY24LMAL Part No. AOY30LMAL Ord. Q'ty Ref. No. Description AOY24LMAL Part No. AOY30LMAL Ord. Q'ty 3 Fan Guard 9371187013 9371187013 4 Emblem-Rear 9359836018 9359836018 5 Cabinet-A, Painted 9359797029 9359797029 6 Cabinet-C, Painted 9363798029 9363798029 7 Noise Ins A 9370181005 9370181005 9 Cabinet-B 9363797022 9363797022 12 Base Assy, Painted 9364145020 9364145020 13-1 3-Way Valve Assy 9372205075 9372205075 16 Condenser Assy 9373254010 9373254010 26-2 Compressor Cover-B 9372067017 9372067017 235 Thermo.(Heat Exchi) 9704220059 9704220059 236 Controller PCB Assy 9704719072 9704719089 (EZ-003PHUE-C) (EZ-003RHUE-C) 255 Insulation ( Heat Sink ) 9370844009 9370844009 333 Accumulator 9351997014 9351997014 343 Solenoid 9900165024 9900165024 343-1 Coil (EXP Valve) 9970006012 9970006012 344 4-way Valve 9900163013 9900163013 353 Thermistor Assy-Out 9703516054 9703516054 373 Grip 9352157004 9352157004 26-3 Compressor Cover-C 9370186000 9370186000 29 Separate Wall-B 9369625015 9369625015 32-7 Control Box Metal-G 9369616006 9369616006 32-8 Control Box Metal-H 9369617003 9369617003 32-9 Control Box Metal-I 9369618000 9369618000 32-10 Control Box Metal-J 9369619007 9369619007 32-11 Control Box-K 9369620010 9369620010 34 Capacitor (Fan Motor) 9704305015 9704305015 39 Propeller Fan 9359837015 9359837015 40 Air seal Plate 9369623004 9369623004 381-2 Locking Spacer 0600035020 0600035020 381-3 Locking Spacer 0600118051 0600118051 408 Special Nut M8 9355091008 9355091008 411 Holder 9372066010 9372066010 412 Terminal Packing 9370290004 9370290004 477 Bell-Mouth 9359809012 9359809012 527 Protectine Net 9359844013 9359844013 549 PTC Thermistor 9704265012 9704265012 629 Coil, Choke 9703458019 9703458019 734 Cabinet Top Plate 9359799023 9359799023 41 Fan Motor Assy Out 9601754015 9601754015 45-1 Motor Bracket-A 9369627002 9369627002 45-2 Motor Bracket-B 9369628009 9369628009 45-4 Motor Bracket-D 9369630002 9369630002 46 Compressor Assy 9373531012 9373531012 47 Comp Plate Assy 9363800005 9363800005 64 Cabinet Left. 9359840022 9359840022 69-3 Bolt, Hex.Socket 301210060360 301210060360 84 Valve Cover 9363802009 9363802009 107 Rubber Seat-A 9358080009 9358080009 764 Drain Cap 313166024302 313166024302 788 Thermistor (Disc Temp. ) 9704219077 9704219077 815 Terminal-6P 9358660089 9358660089 823 Fuse Holder 0500158072 0500158072 824 Fuse 0600086039 0600086039 824-3 Fuse 0600222512 0600222512 824-4 Fuse 0600222529 0600222529 825-1 EXP Valve Assy 9373251019 9373251019 875 Filter PCB Assy 9704722010 9704722010 886 Heat Sink-A 9369792007 9369792007 109 Terminal Cover 9370289008 9370289008 117-3 Hex. Nut w/sp. Washer 301721180114 301721180114 138 2-Way Valve Assy 9372204061 9372204061 176 Valve Fixing Plate-A 9363799064 9363799064 181 ACTPM 9703457012 9703457012 183-1 Water Seal Plate-B 9369626012 9369626012 185-2 Rubber Washer 9358078006 9358078006 186 Frange nut 9358079003 9358079003 203 TR PCB Assy 9704009029 9704009029 204 Heat Sink-B 9369793004 9369793004 887-1 Reactor Cover 9369622007 9369622007 910 Strainer-B 9365099018 9365099018 949-1 Screw, Painted 9305648009 9305648009 950 Accum Support Sheet 9354022010 9354022010 951 Accum SPT AS 313986353804 313986353804 952 Acum HLD Rub 9354022010 9354022010 953 Motor Bracket CTR 9373076018 9373076018 967 Comp Temp Thermo. 9900156015 9900156015 e Seperate Wall Ins B 9360074201 9360074201 ---- Capacitor 9704729019 9704729019 2004.09.15 24

STANDARD ACCESSORIES Models : AWY24LBAJ / AOY24LMAL / AOY30LMAL INDOOR UNIT ACCESSORIES OUTDOOR UNIT ACCESSORIES Name and Shape Part No. Name and Shape Part No. Wall hook bracket 9367987009 Hexagon wrench 9351228019 Remote control unit 9371190112 (AR-JW11) Cable clip Tapping screw 313739340109 301463040100 Battery (penlight) 0600185534 Drain pipe 9303029015 Remote control unit holder 9305642012 Drain cap 313166024302 Putty Drain hose 303020200114 9367695003 Insulation (Drain hose) 9361756007 SERVICE PARTS Tapping screw (big) ( 4 x 20) 301141164200 Name and Shape Service electric filter Part No. Tapping screw (small) ( 3 x 12) 301141533125 UTR-FB11 Holder The holders are attached to the filter frames of the indoor unit. 9367719006 Optional electric filter UTR-FA11 Air purifying filter 9370528022 Deodorizing filter 9370527025 2004.06.16 25

0406G2619