Technical Datasheets. Everlux UL 924 Listed RUNNING MAN Sign C Product. 2. Product Description. 3. Quality and Certification

Similar documents
EXIT Sign model number C with optional directional chevrons.

signs are identified with a unique alphanumeric item code. When ordering, please indicate the following information:

Photoluminescent maritime safety signs

Draft for Comment Please comments to Part A(i)

PHOTOLUMINESCENT EXIT SIGNS EVALUATED AND TESTED TO UL924

Compliance Guide 2015 NFPA 101 LIFE SAFETY CODE EXIT STAIR PATH MARKINGS. for Ecoglo Photoluminescent Markings to meet the requirements of

Low Location Lighting

Date of Authorization JUNE 24, 2004 BMEC Authorization BMEC # AUTHORIZATION REPORT - SafeSIGN Photoluminescent EXIT Signs

Graphic Products,

NCDOI OSFM Evaluation Services

Report of Materials and Equipment Acceptance Division

Page PRODUCT DESCRIPTION

JESSUP JESSUP. GLO BRITE EXIT AND EGRESS Photoluminescent signs and tapes. Adhesive Coated Films. Adhesive Coated Films. Jessup Manufacturing Company

ISO INTERNATIONAL STANDARD. Ships and marine technology Lowlocation lighting (LLL) on passenger ships Arrangement

Photoluminescent emergency pathway marking systems bring a new level of safety to manufacturing environments.

NON ELECTRICAL LOW LEVEL GUIDANCE SYSTEMS EMERGENCY LIGHTING. Photoluminescent Low Level Wayguidance Systems - Overview

SECTION INTERIOR LIGHTING

Ecoglo Photoluminescent Markings

2009 NFPA Text 2009 International Building Code Text Recommendation. NFPA IBC 2009 IBC is most recent

RESOLUTION A.752(18) adopted on 4 November 1993 GUIDELINES FOR THE EVALUATION, TESTING AND APPLICATION OF LOW-LOCATION LIGHTING ON PASSENGER SHIPS

PART 1 GENERAL 1.01 SUMMARY

ISO INTERNATIONAL STANDARD. Ships and marine technology Lowlocation lighting (LLL) on passenger ships Arrangement

2. APTA PR-PS-S , Rev. 3 Standard for Emergency Signage for Egress/Access of Passenger Rail Equipment

SIZES AVAILABLE INDUSTRIAL: ARCHITECTUAL STEP NOSINGS

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Products. Building Products Catalogue. VisibleInnovation.com

Market-Leading Non-Metallic Enclosure Brands

Successful Installation. of PHOTOLUMINESCENT EXIT PATH MARKING SYSTEMS

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

freedom residential concealed pendent lead free sprinkler

All NIGHTBRIGHT photoluminescent signs are non-electric, non-toxic and nonradioactive.

PART 1 GENERAL 1.01 SUMMARY

ISO INTERNATIONAL STANDARD

E10 & L9 Low Wattage Light Cone Data

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Understanding the Regulatory and Standards Process for Products Exported to the U.S. Eric F. Shaver, Ph.D. & Curt C. Braun, Ph.D.

PART 1 GENERAL 1.01 SUMMARY

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

ISO INTERNATIONAL STANDARD

24 Hour Permanent Step Edge Contrasting and Photoluminescent Path Marking Systems

SOUTH AFRICAN NATIONAL STANDARD

freedom residential concealed pendent sprinkler VK488 (K3.0)

Safety Lighting. Safe also without electricity. Standards SIST EN 1838: 2011 ISO (2007) CIE S 020 (2007)

Section: TABLE OF CONTENTS Lighting. 07.A General B Lighting Levels Minimum Lighting Requirements

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Optics & Radiometry Laboratory

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperClear 45-HS (patent pending)

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

Annex A to joint CELMA / ELC Guide on LED related standards: Photobiological safety of LED lamps and lamp systems

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

Fire Safety Log Book. Safety through knowledge East Coast Safety Training. Kevin James (Proprietor) 99 Johnson Estate Wheatley Hill Durham DH6 3LH

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

DESIGN & CONSTRUCTION GUIDELINES

New Fire Safety Order

freedom residential concealed pendent sprinkler vk474 (K5.8)

PART 1 GENERAL 1.01 SUMMARY

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Product Specifications MaxLumen MRI LED Diffused Lighting

WS Circular symbol with red border and bar, black pictogram on white background. Used to prohibit specific acts that could be dangerous.

Emergency Lighting User's Guide

Product Specifications MaxLumen MRI LED Diffused Lighting

Chapter 11. Lighting System

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

11/2016. Protective clothing BUSHFIRE. 3rd category of Personal Protective Clothing

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

NFPA 80 Overview January 21, 2016

Egress Marking Solutions. LiteGuide and Beacon Leading the Way to Safety CECO CORBIN RUSSWIN CURRIES SARGENT YALE

Windstorm Rated Assemblies and Building Products

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

SECTION INTERIOR LIGHTING

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Standard for tests for flammability of plastic materials for parts in devices and appliances

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

1-WAY CEILING CASSETTE FAN COIL UNIT

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

For more information, please visit 3-form.com or call

IOTA Exit Signs. IOTA Emergency Fixtures

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

WZ-T8-W18 T8 LED Tube Light

University of California, Davis Laboratory Self-Inspection Checklist

High Lux Performance White LED MR16 Lamp

Releasing System Peripherals

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Safety Tips for the Office

THE EFFECTS OF SMOKE ON PEOPLE S WALKING SPEEDS USING OVERHEAD LIGHTING AND WAYGUIDANCE PROVISION

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Transcription:

1. Product running man right sign model number C0002. 2. Product Description This sign is manufactured with a strong 1mm thick aluminum base coated with a photoluminescent pigment of high luminous intensity. The sign features an antistatic and easy to clean surface protected with a transparent film. 3. Quality and Certification The quality of products is ensured by a rigorous process of quality control with tests in our own laboratory as well as is third party laboratories observing all applicable Standards, Codes and Legislation. This EXIT sign is UL Listed as per the requirements of UL 924 Emergency Lighting and Power Equipment requirements: UL File Number E479619. C0002_EN_A Edition: 21-02-18 Page 1 of 5

4. Technical Information / Dimensions - 1/32 thick aluminium - High photoluminescent luminous intensity - No power required - Photoluminescent fully charges during exposure for 60 minutes to a fluorescent lamp at least 5ft-c illuminance (54lux) - Maximum Visibility Distance: 50 feet (15.25m) - Designed for surface and flag (for wall) or ceiling mounting - Single sided or double sided installation - The sign will be provided with 4 holes - Size: 15 - ¾ W x 9-3/8 H - Weight: 0.88 lb 5. Brightness Rating (Luminance Properties) According to UL 924 According to UL 924, in stimulation conditions of 54 lux (5 ft-c) during 60 min with a fluorescent cool white source color temperature 4000K, the UL listed EXIT sign will deliver the following luminance performance: Time after removing the exciting light (in minutes) 10 minutes 60 minutes 90 minutes Luminescent intensity mcd/m 2 130 30 20 According to R.S 6.1-A According to RS 6.1, in stimulation conditions of 21.6 lux (2 ft-c) during 120 minutes with a fluorescent cool white source color temperature 4000K, the UL listed EXIT sign will deliver the following luminance performance: Time after removing the exciting light (in minutes) 10 minutes 60 minutes 90 minutes Luminescent intensity mcd/m 2 61.6 21.7 15.5 C0002_EN_A Edition: 21-02-18 Page 2 of 5

6. Installation The sign features 4 holes and is supplied with 4 bolts and 4 plugs which can be used for a direct wall installation: A silver frame is also available and can be supplied, on order, with the respective installation accessories for ceiling and wall (single or double-sided) installation. Wall installation Ceiling installation Accessories: 4 bolts and 4 plugs 4 set screws and a L-Wrench C0002_EN_A Edition: 21-02-18 Page 3 of 5

Installation example: (Additional information is available in the complementary document Instructions for installation ). 7. Dimensions, Pictograms and Colors The products are in conformity to the Standards, Codes and Legislation. catalogue and in compliance with National and International 8. Printing Silk Screen Printing: high quality gloss paint with UV resistance. 9. Washability The sign can easily be cleansed with a dry cloth or with a cloth humidified with water (without detergents). 10. Toxicity The product does not contain any radioactive substances. In toxic terms the product is considered as safe (European standard EN 71-3). 11. Warranty In normal conditions of mounting and adequate cleanness and maintenance, the sign is covered with a 5-year warranty against manufacturing defects. For outdoor applications, considering exposure to varying temperatures, humidity and other extreme environments, the warranty can be diminished. On wet environments or environments with the presence of water with strong acid or alkaline content (eg limestone and chlorine the warranty can be diminished. Additional information on maintenance is available in the complementary document Instructions for installation. C0002_EN_A Edition: 21-02-18 Page 4 of 5

12. Compliance The signs are in compliance with, but not limited to, the following Standards, Codes and Legislation: UL 924 - Emergency Lighting and Power Equipment CAN-ULC-S572-10- Standard for Photoluminescent and self-luminous Exit Signs and Path Marking Systems Reference Standard 6-1 and RS 6-1A Photoluminescent exit path marking as required by local Law 26 of 2004, New York City Building Code 27-383 International Building Code 2009 International Fire Code 2009 California Building Code Connecticut State Building Code NFPA 101 Life Safety Code NFPA 170 Standard for fire safety and emergency Symbols NFPA 5000 ASTM -E2030 Standard Guide for Recommended Uses of Photoluminescent (Phosphorescent) Safety Markings ASTM-E2072 Standard Specification for Photoluminescent (Phosphorescent) Safety Markings ASTM-E2073 Standard Test Method for Photopic Luminance of Photoluminescent (Phosphorescent) Markings ANSI Z535.1 Safety Colors ANSI Z535.2 Environmental Facility and Safety Signs ANSI Z535.3 Criteria for Safety Symbols ANSI Z535.4 Product Safety Signs and Labels ANSI Z535.5 Safety Tags and Barricade Tapes (for Temporary Hazards) ANSI Z535.6 Product Safety Information in Product Manuals, Instructions, and Other Collateral Materials APTA PR-PS-S-004-99, Rev. 2 Standard for Low-Location Exit Path Marking APTA PR-PS-S-002-98, Rev. 3 Standard for Emergency Signage for Egress/Access of Passenger Rail Equipment LEED Leadership in Energy and Environmental Design National Construction Code Series Building Code of Australia New Zealand Building Code C0002_EN_A Edition: 21-02-18 Page 5 of 5