HDPE PIPING SYSTEMS. FIRE FIGHTING APPLICATION by POLYETHYLENE PIPE.

Similar documents
SUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%

Planning Petroleum Contracting Co.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ]

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

SOUTH AFRICAN NATIONAL STANDARD

Fire Hose Reel & Cabinets. Company Profile. 26 Techno Fire & Safety Co. LLC

Enclosure 4- RISK ASSESSMENT

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

In the year 1988, Amit Industrial Corporation is a reputed name in the industry for Manufacturing and

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

DIVISION 21 - FIRE SUPPRESSION

PROFESSIONAL SUPPLIER

DIVISION 21 - FIRE SUPPRESSION

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

PIPE MANUFACTURING CO.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

Design & Construction Standards, Revised January

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

A. This section includes design and performance information for fire protection and suppression systems.

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

Western Michigan University Facilities Management Engineering Division

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

Standard for tests for flammability of plastic materials for parts in devices and appliances

PLAN REVIEW CHECKLIST

TECHNICAL AND USER REQUIREMENTS FOR FIRE-FIGHTING PRESSURE HOSES FOR FIRE-FIGHTING PUMPS

Delhi Metro System. Emergency and Fire Safety Measures in. - by Sanjeev Kumar & Kailash Chandra Joshi. Fire Protection & Safety

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Discontinued Product

Series 759 FireLock Alarm Check Valve

PROJECT: NITESH PALO Bangalore FIRE SAFETY MEASURES

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

Environmental Health & Safety

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

Sprinkler Permit Applications

SECTION WET-PIPE SPRINKLER SYSTEMS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

EASTERN ARIZONA COLLEGE Fire Department Operations I

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

SECTION SPRINKLER SYSTEMS

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

BALAJI FIRE PROTECTION SYSTEMS:

Driver Operator Pumps: Sprinkler and Standpipe Operations

SUPRON 3 8 CE certificates 1 volountary certificate 12 Certificates of admittance PN-EN ISO 9001:2009

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

I. It shall be the responsibility of the department officers to implement this operating guideline.

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

Fire Protection Coffee Break Training May 2016

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

NZS 4510:2008 Incorporating Amendment No. 1. New Zealand Standard. Fire hydrant systems for buildings. Superseding NZS 4510:1998 NZS 4510:2008

MSC Guidelines for Foam Fire Suppression Systems

PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES

FIRE STOP 200/30. High technology system for first attack of fire with high pressure nebulized water (Water mist) FD 907. Ed.

1 Exam Prep. Questions and Answers

Additional Requirements for Watermist Systems Protecting High-rise Buildings

Technical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm

Ramp up. Ramp up. Ramp up 7,540 3,414 3,957 3,761 3,800. Fire Hose Reel. Fire. Lift Lobby Granito tiles DN DN 2,932 ENTRANCE GATE

Outline of Measures for Fire Prevention and Safety under the Laws and Regulations of Fire Fighting

D. Reference Standards (Utilize latest editions available):

Yankee Dryer Safety. Program

MODEL V-BB SPECIFIC APPLICATION TECHNICAL DATA

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

TECHNICAL DATA MODEL V-HIP SPECIFIC APPLICATION ATTIC SPRINKLER VK660

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

Fire Permit Application

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable

Standards: Issues and Challenges

micromatic standard response stainless steel sprinklers

MARLOW PUMPS RECIRCULATION

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

MSC Guidelines for Automatic Sprinkler Systems

SECTION FIRE PUMP AND CONTROLS

Some Important Aspects of Fire Safety Regulations about High Rise Buildings

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler systems Part 11: Requirements and test methods for pipe hangers

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

SECTION DRY-PIPE SPRINKLER SYSTEMS

EASTERN ARIZONA COLLEGE Fire Department Operations II

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

DISASTER MANAGEMENT PLAN 3.0 IDENTIFICATION OF MAJOR HAZARD POTENTIAL

Schedule of Accreditation

Design & Construction Standards, Revised January

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

PLAN REVIEW SUBMITTAL GUIDE

SECTION DRY-PIPE SPRINKLER SYSTEMS

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

Annex of the Certificate (Page 1/7) Scope of Accreditation

Transcription:

HDPE PIPING SYSTEMS FIRE FIGHTING APPLICATION by POLYETHYLENE PIPE

HDPE PIPE (POLYETHYLENE PIPE) FOR FIRE FIGHTING PIPING SYSTEMS 1 - GENERAL PRINCIPLES OF FIRE FIGHTING SYSTEMS Fire fighting systems "The Regulation of the Building Fire Protection" provisions, will be designed in accordance with the relevant fire fighting and polyethylene piping sytems world standards and installation regulations to be established and approved. The provisions of this regulation, if there is a change in the applicable standards of hdpe piping systems and hdpe pipe installation regulations will be designed in accordance with this change will be established and approved. 2- WATER STORAGE AND WATER RESOURCES BY HDPE PIPING Dedicated sections of the reserve water tank to be used for fire fighting systems will not be used for other purposes and storage systems with HDPE piping will be arranged to serve only hdpe pipe fire fighting systems. Firstly polethylene pipes and other kind of plastic pipes, provide returns significantly for fire fighting projects. HDPE pipes chemical resistance is very strong, when compared with the less developed they are wear-resistant material is an important factor in the fire system.

HDPE pipes are located in quite well as fire systems are preferred in many areas. Water tank capacity, according to the structure of the fire hazard class in fire regulations shall not be less than the specified value, the design flow rate for unit area (design density) will be based on the relative fire fighting and hdpe piping standards. Some of the standard are EN 12201-2, BS EN 12201-2, for the fire fighting systems FM Approvals on the polyethylene pipes quality. In the structure if the sprinkler system is fire cabinets only system available water capacity shall be calculated according to fire regulations for fixed fire extinguishing systems. Only in the event of hydrant system does the structure environment at least 1,900 liters of water flow needs to be done according to the nature of the risk categories, including the capacity to meet for 90 minutes will be determined by hydraulic calculations. Before the installation polyethylene pipe must be tested by the quality laboratuvars of the hdpe pipe manufactrurer factory plant and the test report must be provide to the buyer. It is a way also hdpe pipe manufacturer s technical support must be with the applicator, that support could provide in the area of fire fighting hdpe pipe sytems. The test reports of the polyethylene pipes gives the details of the pressures of pipe, density, flow rates and with the report high density polyethylene pipes applicable for the fire fighting project. The fire fighting systems is need the fittings as well as pressurized hdpe pipes as pressurized hdpe pipe fittings and cast iron valves, pressure reducing valves, underground & aboveground fire hydrants suitable for the piping systems. The high density polyethylene pipes must be supply for the outlet of the fire systems, inlet piping systems, domestic piping systems and the hdpe piping usable in special fire works mainly must be have for the maximum working pressure to which the piping is exposed to but must not be have less than 150 psi /10 bar pressure. Polyethylene pipe diamters has stated in below table with the inch values.

3- PUMPS Fire pump providing pressurized water from HDPE pipe to the sprinkler system, the nominal flow rate and pressure pumps are expressed in nominal value. If you use the pump in the polyethylene piping system must be redundant pumps in the same capacity. Provided that a sufficient number of spare pumps backed up at least 50% of the total capacity will be used in case of multiple pumps 4- FIXED POLYETHYLENE PIPING AND FIRE CABINETS HDPE pipe connections on all fixed piping shall be in accordance with the standards used by the fire department. The polyethylene pipe applicable some norms of ASTM 3350, EN 12201, BS EN 12201, ISO 4427 usable in fire fighting systems. In the application must be have the staff who are experienced about HDPE pipe laying, pipe connecting and polyethylene pipe welding such as trained staff. HDPE pipe for fire cabinets must comply with the standards to which they relate. HDPE pipes in accordance with the standard norms that are round about half-hard, HDPE pipe diameter and pipe length should be appropriate to the project should not exceed the quantities in the project. Nozzle or lance off, spraying and / or be able fountain. Fire mouth without water getting round semi-rigid HDPE pipe fire cabinet design flow of 100 l / min and pressure in the launch entry must be 400 mpa. If it is exceed 700 mpa of pressure, then pressure reducing valves

should be used. Flat HDPE pipe can be used in structures which have to keep the trained fire fighters that they must conform to standards regarding fire cabinets. Flat HDPE pipe nominal diameter of 50 mm and a length of hose 20 m shall not exceed. 5-HYDRANT SYSTEMS FOR HDPE PIPING IN FIRE SYSTEMS In the fire protection of buildings, first intervention in extinguishing non-fire to be established in order to cover as much structure or the entire perimeter of the building it is possible to interrupt the external HDPE pipe hydrant system to be installed on-site fire hydrants, fire department and should be organized in a way that can easily approach can and connectivity tools. Hydrant system should be design flow at least 1900 l / min flow rate should be, and should be increased according to the risk class structure. Fire hydrants in the output should be pressure 700 mpa. The distance between hydrants is too risky areas 50 m, 100 m-risk areas, medium-risk zone 125 m, 150 m must be taken in low-risk areas. Under the normal conditions, the average 5-15 m hydrants should be located as far away from the protected building.

6- AUTOMATIC SPRINKLER EXTINGUISHING SYSTEMS Sprinkler system components and system design must conform to the standards to which they relate. Sprinkler Protection Area (m2): One area can protect the sprinklers. Low hazard class field for 18-21 m2, 12 m2 for medium hazard class and 8-12 m 2 for high hazard class Sprinklers Application: Low and medium hazard class 139m 2 and 232m 2 for high-hazard class Maximum Floor Area: Low to medium hazard class of 4830 m 2, for high hazard class in calculation statements made with HDPE pipe tables that value in 2320 m 2, 3715 m2 in hydraulic calculations. Application Rate (flow rate): 4.1 liters for low hazard class. / Min / m 2 For medium hazard class 6.1... 8.1 liters. / Min / m 2 For high hazard class 12.3... 16.3 liters. / Min / m 2 Operate design Pressure: Max. 12 Bar Distance Between Sprinklers: Standard types of outlets on or between deployed maximum distance between sprinklers for low and medium hazard class 4.6 m and 3.7 m for high hazard class. The distance between the wall-mounted hood can be approved according to the conservation area. If the sprinkler heads have to be placed closer than 1.8 m, the curtain between sprinkler heads (division) should be placed.sprinkler distance from the wall of the title two sprinklers should not be more than half the allowable distance is 10cm from the wall should not be justified in the title or closer.