DIESEL ENGINE AUTOMATICS

Similar documents
M2000 Engine Controller

M2000 Engine Controller

M2500 Engine Controller Installation Manual

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

DGC-500 DIGITAL GENSET CONTROLLER

Process Alarm Solutions

M1000 Alarm Annunciator

DGC-1000 DIGITAL GENSET CONTROLLER

APPLICATION DATA SHEET

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability

EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability

HGM1750 Automatic Generator Module OPERATING MANUAL Smartgen Electronics

Across-the-Line SERIES MP300 Combined Manual and Automatic

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

Rittal roof-mounted fans Efficiency on top

APP 721 MODBUS Mapping

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Technical Manual. Level Alarm Unit CARLA & WIDS

Soft Start Series MP700 Solid State, Reduced Voltage

Generator Paralleling Controller, GPC-3 Hydro Start and stop sequences, water level control

User s Manual DCU 305 R3 DCU 305 R3 LT. Diesel Engine Control Unit. Auto-Maskin

Universal fault annunciator for panel mounting

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Moulded case circuit brakers

Variable Frequency Drive SERIES MP800 VFD

Constant climate chambers

APPLICATION DATA SHEET

ME 3011C / Alarm Indication / Quick Reference Guide

21-light Remote Annunciator. Owner s Manual

How to use the BTRM in Remote Enclosures

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

REMOTE CONTROL FOR CHILLER MYCHILLER

Digital Control Systems & Remote Communications Options

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

Frequently asked questions: Intelligent Transmitter Series

Spectron LSN (Life Safety Network) Suggested Specifications

Engine Control Unit, ECU 100 Functional description Additional functions Parameter list

20 Light Remote Annunciator

INSTALLATION INSTRUCTIONS. Anti Knocking System, AKR 3. Document no.: A SW version:

Fire Pump Controllers Foam (Additive) Controllers

B. Section Transfer Switches: Automatic transfer switch.

STA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

SMS GSM Alarm Messenger

Parameterisable compact fault annunciator with permanent display

SCIENTIFIC WARMING CABINET Installation, Operation and Maintenance Instructions

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

Metasys Integrator Liebert Application

Panel Mounted Fault Annunciator Series

RACK MONITORING SYSTEM - RAMOS Ultra

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

XLH210: controller for gas leak detectors

SALES SUPPORT DOCUMENT

Installer Certification Expiration. Terms

MiLAB Oxygen Control MANUAL & INSTALLATION. MOC-100 Ver 3.0

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Ferrous debris monitoring. Ferrous debris in oil

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

BS-100 DYFI. Installation handbook. Protecting environment, life and property... P-BS100/DCE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

EKL3 short circuit and earth fault indicator

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

ProSens Dust Measurement

Sentry G3 Machinery Protection Monitor

Sentry G3 Machinery Protection Monitor

Quick Alert Remote (QA216R)

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

DIESEL Engine Fire Pump Controllers Features

931D Style B Process Gas Chromatograph

Dusty / Dusty Ex Low-Cost Broken Bag Detection

PowerWizard Range. Digital Control Systems & Remote Communication Options.

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

Constant voltage charger. Type UP 610. »We store the world's energy« Network

Danfoss gas detection units

THE CHANGE IN GEAR ENGINEERING

EP364 USER MANUAL ALARM AND MANAGEMENT SYSTEM

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

P2267 NETWORK INTERFACE

INSTALLATION INSTRUCTIONS

MHC Series Sensors

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

INDEX. 1.1 Main Features Environmental Conditions and Power Requirement Optional Accessories Tyre-Killer Main Parts...

Measuring Recording Online Monitoring Regulation Alarming

LAYOUT The system requires no data network. Very simple installation. Only 220V ac power supply indispensable. LEGEND P ET C P COIN BAR PAN KIT CAP

BlueSpin Magnetic Hotplate Stirrer

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

REC-8R Environmental Control. Operation and Installation Manual

Panel Mounted Fault Annunciator Series

INSTALLATION INSTRUCTIONS

Mark 25 Ultrapure Water Conductivity Analyzer

Transcription:

DIESEL ENGINE AUTOMATICS MANUAL Address: UTE d.o.o. ULJANIK TESU ELEKTRONIKA Flaciusova 1 52100 PULA REPUBLIC of CROATIA Phone: +385 (52) 38 53 50 Fax: +385 (52) 38 53 51 E-mail ute@pu.hinet.hr Cat. N.: BR001102E.1 Page 1 (1)

1. FRONT PANEL VIEW POWER START STOP START. STOP RUNNING OVERSPEED OIL PRESS. WATER TEMP. WATER LEV. SHORT CIRC. ALARM FUEL LEAK. LAMP TEST Fig. 1. Alarms and commands in standard version 2. APPLICATION: Manual Diesel Engine Control Unit is intended for alarm monitoring and manual control of diesel engine. Very often this is the engine of a diesel generating set. The control is manual via the keyboard on front panel. It includes the indispensable protections of engine such as: - overspeed, - too high temperature, - lubricating oil low pressure and - fuel low level - short circuit - generator overloaded Cat. N.: BR001102E.1 File: e knjiga uputa Page 2 (2)

3. BRIEF DESCRIPTION: The Control Unit is housed in a box of DIN standard dimensions (72x144 mm) and is intended for being built in the panel or door of switch gear cabinet. It is supplied from the diesel-engine starting batteries or some other uninterruptable DC supply in range of 10-29 V DC. It is made in CMOS technology with microprocessor control and special attention is paid to safe operation, low consumption, wide supply voltage range and resistance to disturbances on the input - output terminals. ADA 1011 has RS 485 communication port with MODBUS protocol. Parameterisation of automatics is terminal. via PC and appropriate software or via hand 3.1. Inputs - information to ADA-1010 unit are: Input from speed sensor which can be: - tacho-generator (AC voltage), - passive pick-up (magnetic) and - active pick-up (inductive or capacitive). Contacts from usual sensors such us: - temperature switch - oil pressure switch - fuel oil low level switch - other possible contacts of alarm conditions 3.2. Outputs - from control unit are relay contacts for: - diesel engine start and stop - alarm siren - genset operating indication. - critical alarm - noncritical alarm 3.3. ALARM CONDITIONS are grouped in: Critical non-critical - which stop the engine and - which produce alarm but do not stop the engine operation. 3.4. CRITICAL ALARMS in standard version are: - overspeed, - engine high temperature, - lubrication oil low pressure 3.5. NON-CRITICAL ALARMS in standard version are: - fuel low level Cat. N.: BR001102E.1 File: e knjiga uputa Page 3 (3)

Beside these alarms, four more input channels could be used for alarms. Every alarm can be choosen as critical or non critical via communication (except overspeed wh ich is allways critical). Cooling water high temperature can have stop delay. 4. METHOD OF OPERATION: Engine starting is manual via the START key on front panel. Stopping can also be effected manually via STOP key but it is also automatic in case the critical alarms appear. When non-critical alarms appear the alarm siren is on but the engine is NOT stopped. The standard version is maximally adjusted to different versions of engines it will be used with but it is also possible to agree with customer / user on details of operation of automatics. The customer can request some non standard details e.g. specific values of time delays or similar. T.G. A 1 RS485 + _ Tacho generator 3-20 V, 50 Hz Fuse 2 A slow B 1 B 2 B 3 B 4 B 5 B 6 B 7 B 8 B 9 B 10 B 11 B 12 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 GND -Rx/Tx +Rx/Tx Sensors: Overspeed Lub oil pressure Cool. wat. temp. Fuel oil level Short circuit Gener. overload Alarm 7 Alarm 8 0 V Plus pole of supply C 1 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C 9 C 10 C 11 C 12 D 1 D 2 D 3 D 4 D 5 D 6 D 7 D 8 D 9 D 10 D 11 D 12 Start Stop - + Outputs Generator running Siren Critical alarm Noncritical alarm max. 100 V, 6 A Inputs Sensors external commands SUPPLY min. 10 V max. 29 V Fig. 2. Connection diagram of automatics Cat. N.: BR001102E.1 File: e knjiga uputa Page 4 (4)

PULA B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 A1 A2 A3 A4 A5 A6 A7 A8 A9 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 Fig. 3. Rear panel view Cat. N.: BR001102E.1 File: e knjiga uputa Page 5 (5)

143,00 136,00 130,00 149,00 Fig. 4. Mechanical dimensions Required depth is: 149 mm, plus space for wires which are connected on the rear side terminals. Cat. N.: BR001102E.1 File: e knjiga uputa Page 6 (6)

66 136 Fig. 5. Cutout in panel Cat. N.: BR001102E.1 File: e knjiga uputa Page 7 (7)