HIGH BAY APPLICATIONS

Similar documents
ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

NYC Approved Product Series

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

IOTA Exit Signs. IOTA Emergency Fixtures

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Spectron LSN (Life Safety Network) Suggested Specifications

SERVICE BY QUALIFIED PERSONNEL ONLY

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

XET-20 Series 20 Amp Emergency Lighting Control Device

Catalog Number. Notes

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

CDL8 LED Architectural

Bdl60u Fluorescent Emergency Ballast

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Emergency Lighting. Product Guide LED. The right source for the. right light

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Related Sections: TBD. Effective Date: January 1, 2016

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

USER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050

Installation Instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.


WARRANTY LED ECO PANEL.

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

UNIFIED FACILITIES GUIDE SPECIFICATIONS

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

BAS SFP22 Edge-lit LED Panel

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Applications Cookbook ASHRAE Standard Version 5.0 FOR REFERENCE ONLY

LED RETROFIT SOLUTIONS

LED ECO PANEL.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

Applications Cookbook 2015 IECC Version 3.0 FOR REFERENCE ONLY

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

LED RETROFIT CONVERSION KITS

LED RETROFIT CONVERSION KITS

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

Emergency TLED Lighting Retrofit 101. December 6 th 2017

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

Installation Instructions

Applications. Standard Materials

Installation Instructions

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Stellar Panelboard Dimming Systems

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

UltraLITE MODEL ELU. Centralized Emergency Lighting Inverters

Grüv Flare Regressed. Recessed Linear LED

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

Grüv Flare Regressed. Recessed Linear LED

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

SECTION INTERIOR LIGHTING

UltraLITE. Centralized Emergency Lighting Inverters MODEL ELU

LED Edge-Lit Flat Panels

Unison Echo Room Controller

1 x4 Dimmable LED RetroFits

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

WARRANTY LED ECO PANEL.

Exit/Emergency Lighting Guide

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

Applied Lighting Controls

TROFFER RETROFIT KIT (TRK)

Installation Guide for models:

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: 1.4 Warranty SECTION BATTERY EMERGENCY POWER SUPPLY PART 1 - GENERAL

FIRE ALARM: BY OTHERS, IF REQUIRED.

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

TERRALUX RETROFIT LED LIGHTING

elite TM SERIES Centralized Emergency Lighting Inverters MODEL ELE

Installation Instructions

LED ECO PANEL.

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Project. Comments. Prepared by

Innovative Lighting Smooth Light Recessed Luminaires

MANUFACTURED IN THE UK

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

Transcription:

STAIRWELLS The IIS Inverter can operate multiple fixtures in a building s stairwell and can be wired to bypass dimmers or occupancy sensors...keeping your egress corridors lit without sacrificing your facility s energy-saving controls. HIGH BAY APPLICATIONS High bay fixtures can take advantage of the IIS Inverter s full light output...use the no break capability of the IIS-350-U to keep HID fixtures operating, or use the IIS-375-I to operate up to (6) 54W T5 lamps. DECORATIVE FIXTURES Hospitality and restaurant applications can utilize existing decorative fixtures for emergency lighting in place of unattractive wall-mount fixtures. In addition, the IIS Inverter will operate LED fixtures on the emergency circuit regardless of voltage or wattage. 2 IOTA Engineering tel: 1.800.866.4682

IIS SERIES UNIT INVERTER SYSTEMS IIS Series Inverters combine IOTA s extensive experience in innovative emergency lighting technology with durable and reliable inverter system design. The IIS Series delivers maximum illumination for LED, fluorescent, incandescent, and HID loads from one convenient supply in egress applications that other emergency options can t match... HIGH ATRIUM CEILINGS The IIS inverter is perfect for vaulted or high atrium ceilings in lobbies, foyers and other critical points of egress. OUTDOOR EGRESS The IIS Inverter installs within the interior and is unaffected by exterior conditions. Illuminate walkways, handrails, steplights, or bollards remotely up to 1000 feet. FEATURES INCLUDE... UL 924 Listed Valve Regulated Lead Acid (VRLA) Battery provides long life and is maintenance-free Line Voltage allows for remote mounting of emergency fixtures at distances of 1000 feet Low Voltage Disconnect and Line Latch Protection Features Meets or exceeds all National Electrical Code and Life Safety Emergency Lighting Requirements Durable Steel Design with Powder-Coat Finish Three-Year Warranty with Seven-Year Pro Rata Battery Warranty. fax: 520.741.2837 3 www.iotaengineering.com

INTERRUPTIBLE 125 WATT IIS-125 IIS-125-SM OPERATES: FLUORESCENT LED IIS-125-CG INCANDESCENT FEATURES IOTA s IIS-125 Inverters are UL Listed stand-alone simulated sine wave output inverters designed to provide power to designated emergency lighting fixtures. In a power loss situation, the IIS-125 will supply 125W of power from the onboard battery supply. IIS-125 inverters work in conjunction with incandescent, LED, and fluorescent lamp and fixture types and will automatically run switched, normallyon, or normally-off designated emergency fixtures. The IIS-125 is available in two mounting styles: a ceiling grid configuration (IIS-125-CG) and a surface mount design (IIS-125-SM). IOTA s 125W inverter models come with a three-year warranty and seven-year pro-rata battery warranty. TECHNICAL SPECIFICATIONS Input Voltage... (Dual) 120/277V, 60Hz Input Rating (bulk)... 150 Watts Output Voltage... (Dual) 120/277V, 60Hz Output Power... 125 Watts at.9 leading to.9 lagging PF Lamps Operated... LED, Fluorescent, Incandescent Transfer Time... less than 50 milliseconds Emergency Operation... 90 minutes Voltage Regulation (emergency)... +/- 10% Frequency Regulation (emergency)... +/- 3% Load Power Factor Range....9 leading to.9 lagging Operating Temp... 20 to 30 C Battery... Valve Regulated Lead Acid (VRLA) Weight... (IIS-125-CG) 42.5 lbs. (IIS-125-SM) 46.0 lbs. Approval... UL 924 Listed Emergency lighting supplied from one convenient source Operates incandescent, LED, and fluorescent fixtures including fixtures with dimmable fluorescent ballasts Two available mounting options Includes momentary contact test switch, yellow ready indicator, green inverter-on indicator, and red charging indicator Dual voltage 120/277 60Hz Replaceable output fuse protection High efficiency modified sine wave inverter Variable-rate, temperature-compensated charger Valve Regulated Lead Acid (VRLA) battery provides long-life and is maintenance free Line voltage allows for remote mounting of emergency fixtures at distances up to 1000 feet Low Battery Voltage Disconnect Line Latch Protection Allows for operation of switched fixtures Dimming Relay option for dimming control applications Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements Durable 18 gauge steel housing design with white semi-gloss powder-coat paint finish 3/7 Pro-Rata Warranty 4 IOTA Engineering tel: 1.800.866.4682

IIS-125-CG AND IIS-125-SM ORDERING GUIDE Use the Ordering Guide below to determine the Catalog # of the model required for your application. IIS-125- - CG SM Ceiling Grid model mounts across the 2-feet T-bars of a grid ceiling. Support wires are connected to the mounting tabs at the top of the unit and secured to the building framework. Knock-outs are located on one end of the unit for connecting conduit containing the AC supply and fixture leads. A 1.25 inch flange on either side provides support for the re-sized ceiling tile. Surface Mount model installs directly to the wall. Keyhole slots at the back of the unit are spaced for secure mounting to the wall s unistrut or studs. Knockouts provide rear or side access for connection of wiring conduit. An additional hole is provided to prevent inadvertent lifting of the unit from the keyholes. DR (Blank) Dimming Relay (Optional) Refer to Page 14 for DR application details. No Dimming Relay option. DIMENSIONS IIS-125-CG IIS-125-SM WIRING DIMMING RELAY BLUE (NORMALLY OPEN) RED (COMMON) BROWN (NORMALLY CLOSED) INPUT LEADS The IIS Inverter utilizes two sets of input leads: one to provide unswitched power to the inverter system and a second to serve as a normal power input to the lighting load. Any switch for the designated emergency circuit will be present on the Normal Power Input leads. For Emergency Operation Only applications, the Normal Input leads are not needed and would remain disconnected and capped. fax: 520.741.2837 The dimming relay leads allow for a dimming signal to operate the luminaires in the desired, dimmed state during normal operation. The IIS inverter will then bypass the dimming control to operate fixtures at full light output in the event of a loss of normal AC power. Additionally, if desired, the dimming leads can be wired to operate the luminaires at a reduced lumen output setting based on the dimmable driver(s) being used during emergency operation. Refer to Page 14 for details. 5 www.iotaengineering.com

INTERRUPTIBLE 375 WATT IIS-375-I OPERATES: FLUORESCENT FOR FLUORESCENT AND INCANDESCENT LOADS INCANDESCENT FEATURES The IOTA IIS-375-I is a UL Listed stand-alone sine wave output inverter designed to provide power to designated emergency lighting fixtures. In a power loss situation, the IOTA IIS-375-I will supply 375W of power from the onboard battery supply. The IOTA IIS-375-I works in conjunction with incandescent and fluorescent lamp and fixture types and will automatically run switched, normally-on, or normally-off designated emergency fixtures. The IIS-375-I features a surface mount housing and comes with a three-year warranty and seven-year pro-rata battery warranty. TECHNICAL SPECIFICATIONS Input Voltage... (Dual) 120/277V, 60Hz Input Rating (bulk)... 500 Watts Output Voltage... (Dual) 120/277V, 60Hz Output Power... 375 Watts at.9 leading to.9 lagging PF Lamps Operated... Fluorescent, Incandescent Transfer Time... less than 50 milliseconds Emergency Operation... 90 minutes Voltage Regulation (emergency)... +/- 2% @ 15% to 110% load Frequency Regulation (emergency)... +/-.5% Load Power Factor Range....9 leading to.9 lagging Operating Temp... 20 to 30 C Battery... Valve Regulated Lead Acid (VRLA) Weight...114 lbs. Approval... UL 924 Listed Emergency lighting supplied from one convenient source Pure sine wave output Operates incandescent and fluorescent fixtures including fixtures with dimmable fluorescent ballasts Includes momentary contact test switch, yellow ready indicator, green inverter-on indicator, and red charging indicator Dual voltage 120/277 60Hz High efficiency pure sine wave inverter Variable-rate, temperature-compensated charger Valve Regulated Lead Acid (VRLA) battery provides long-life and is maintenance free Line voltage allows for remote mounting of emergency fixtures at distances up to 1000 feet Resettable output circuit breaker provides protection against circuit overload Low Battery Voltage Disconnect Line Latch Protection Allows for operation of switched fixtures Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements Durable 16 gauge steel housing design with white semi-gloss powder-coat paint finish 3/7 Pro-Rata Warranty 6 IOTA Engineering tel: 1.800.866.4682

IIS-375-I ORDERING GUIDE IIS-375-I Surface Mount design for surface or shelf mounting. Keyhole slots at the back of the unit are spaced for secure mounting to the wall s unistrut or studs. After AC supply and fixture leads are routed to the wall location, the IIS-375-I is secured to the wall unistrut or studs. Dual knockouts are present on the sides of the unit for separate input and output conduits external to the wall if needed. An additional hole is provided to prevent inadvertent lifting of the unit from the keyholes. Always consult local codes for structural requirements when mounting the unit. MOUNTING SCREWS UNISTRUT OR WALL STUD DIMENSIONS IIS-375-I WIRING fax: 520.741.2837 INPUT LEADS The IIS Inverter utilizes two sets of input leads: one to provide unswitched power to the inverter system and a second to serve as a normal power input to the lighting load. Any switch for the designated emergency circuit will be present on the Normal Power Input leads. For Emergency Operation Only applications, the Normal Input leads are not needed and would remain disconnected and capped. INTERNAL CIRCUIT BREAKER The internal circuit breaker protects the inverter from overload on the output side of the unit. Internally, the appropriate voltage lead is selected for connection to the line side of the circuit breaker and the designated emergency load connects to the single Yellow/Violet 120/277V hot lead. 7 www.iotaengineering.com

INTERRUPTIBLE 375 WATT IIS-375-LED DESIGNED WITH TAILORED SPECIFICALLY FOR: LED FOR CONFIDENT HANDLING OF THE HARSHEST LED LOAD REQUIREMENTS... The specialized design of the IIS-375-LED enables the inverter to handle the increased in-rush demands generated by multiple LED fixtures on the load, which can result in unexpected shutdown of inverters not equipped to properly handle these sudden power demands... FEATURES The IOTA IIS-375-LED is a UL Listed stand-alone sine wave output inverter designed to provide power to designated emergency lighting fixtures. In a power loss situation, the IOTA IIS-375-LED will supply 375W of power from the onboard battery supply. The IOTA IIS-375-LED is designed specifically for LED applications and will prevent shutdown caused by in-rush currents of LED drivers. The IIS-375-LED will automatically run switched, normally-on, or normally-off designated emergency fixtures. The IIS-375-LED features a surface mount housing and comes with a three-year warranty and seven-year pro-rata battery warranty. TECHNICAL SPECIFICATIONS Input Voltage... (Dual) 120/277V, 60Hz Input Rating (bulk)... 500 Watts Output Voltage... (Dual) 120/277V, 60Hz Output Power... 375 Watts at.9 leading to.9 lagging PF Lamps Operated... LED Transfer Time... less than 50 milliseconds Emergency Operation... 90 minutes Voltage Regulation (emergency)... +/- 2% @ 15% to 110% load Frequency Regulation (emergency)... +/-.5% Load Power Factor Range....9 leading to.9 lagging Operating Temp... 20 to 30 C Battery... Valve Regulated Lead Acid (VRLA) Weight...114 lbs. Approval... UL 924 Listed Emergency lighting supplied from one convenient source Pure sine wave output Designed to operate multiple LED fixtures, including dimmable LED drivers, and accommodate varying in-rush requirements. Includes momentary contact test switch, yellow ready indicator, green inverter-on indicator, and red charging indicator Dual voltage 120/277 60Hz High efficiency pure sine wave inverter Variable-rate, temperature-compensated charger Valve Regulated Lead Acid (VRLA) battery provides long-life and is maintenance free Line voltage allows for remote mounting of emergency fixtures at distances up to 1000 feet Resettable output circuit breaker provides protection against circuit overload Low Battery Voltage Disconnect Line Latch Protection Allows for operation of switched fixtures Dimming Relay option for dimming control applications Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements Durable 16 gauge steel housing design with white semi-gloss powder-coat paint finish 3/7 Pro-Rata Warranty 8 IOTA Engineering tel: 1.800.866.4682

IIS-375-LED ORDERING GUIDE Use the Ordering Guide below to determine the Catalog # of the model required for your application. IIS-375-LED - Surface Mount design for surface or shelf mounting. Keyhole slots at the back of the unit are spaced for secure mounting to the wall s unistrut or studs. After AC supply and fixture leads are routed to the wall location, the IIS-375-LED is secured to the wall unistrut or studs. Dual knockouts are present on the sides of the unit for separate input and output conduits external to the wall if needed. An additional hole is provided to prevent inadvertent lifting of the unit from the keyholes. Always consult local codes for structural requirements when mounting the unit. MOUNTING SCREWS UNISTRUT OR WALL STUD DR (Blank) Dimming Relay (Optional) Refer to Page 14 for DR application details. No Dimming Relay option. DIMENSIONS IIS-375-LED WIRING LED DIMMING RELAY BLUE (NORMALLY OPEN) RED (COMMON) BROWN (NORMALLY CLOSED) INPUT LEADS The IIS Inverter utilizes two sets of input leads: one to provide unswitched power to the inverter system and a second to serve as a normal power input to the lighting load. Any switch for the designated emergency circuit will be present on the Normal Power Input leads. For Emergency Operation Only applications, the Normal Input leads are not needed and would remain disconnected and capped. fax: 520.741.2837 INTERNAL CIRCUIT BREAKER The internal circuit breaker protects the inverter from overload on the output side of the unit. Internally, the appropriate voltage lead is selected for connection to the line side of the circuit breaker and the designated emergency load connects to the single Yellow/Violet 120/277V hot lead. The dimming relay leads allow for a dimming signal to operate the luminaires in the desired, dimmed state during normal operation. The IIS inverter will then bypass the dimming control to operate fixtures at full light output in the event of a loss of normal AC power. Additionally, if desired, the dimming leads can be wired to operate the luminaires at a reduced lumen output setting based on the dimmable driver(s) being used during emergency operation. Refer to Page 14 for details. 9 www.iotaengineering.com

INTERRUPTIBLE 550 WATT IIS-550-I OPERATES: FLUORESCENT FOR FLUORESCENT, INCANDESCENT, AND LED LOADS LED INCANDESCENT FEATURES The IOTA IIS-550-I is a UL Listed stand-alone sine wave output inverter designed to provide power to designated emergency lighting fixtures. In a power loss situation, the IOTA IIS-550-I will supply 550W of power from the onboard battery supply. The IOTA IIS-550-I works in conjunction with incandescent, LED, and fluorescent lamp and fixture types and will automatically run switched, normally-on, or normally-off designated emergency fixtures. The IIS-550-I features a surface mount housing and comes with a three-year warranty and seven-year pro-rata battery warranty. TECHNICAL SPECIFICATIONS Input Voltage... (Dual) 120/277V, 60Hz Input Rating (bulk)... 675 Watts Output Voltage... (Dual) 120/277V, 60Hz Output Power... 550 Watts at.9 leading to.9 lagging PF Lamps Operated... LED, Fluorescent, Incandescent Transfer Time... less than 50 milliseconds Emergency Operation... 90 minutes Voltage Regulation (emergency)... +/- 2% @ 15% to 110% load Frequency Regulation (emergency)... +/-.5% Load Power Factor Range....9 leading to.9 lagging Operating Temp... 20 to 30 C Battery... Valve Regulated Lead Acid (VRLA) Weight...145 lbs. Approval... UL 924 Listed Emergency lighting supplied from one convenient source Pure sine wave output Operates incandescent, LED, and fluorescent fixtures including fixtures with dimmable fluorescent ballasts or LED drivers Includes momentary contact test switch, yellow ready indicator, green inverter-on indicator, and red charging indicator Dual voltage 120/277 60Hz High efficiency pure sine wave inverter Variable-rate, temperature-compensated charger Valve Regulated Lead Acid (VRLA) battery provides long-life and is maintenance free Line voltage allows for remote mounting of emergency fixtures at distances up to 1000 feet Resettable output circuit breaker provides protection against circuit overload Low Battery Voltage Disconnect Line Latch Protection Allows for operation of switched fixtures Dimming Relay option for dimming control applications Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements Durable 16 gauge steel housing design with white semi-gloss powder-coat paint finish 3/7 Pro-Rata Warranty 10 IOTA Engineering tel: 1.800.866.4682

IIS-550-I ORDERING GUIDE Use the Ordering Guide below to determine the Catalog # of the model required for your application. IIS-550-I- Surface Mount design for surface or shelf mounting. Keyhole slots at the back of the unit are spaced for secure mounting to the wall s unistrut or studs. After AC supply and fixture leads are routed to the wall location, the IIS-550-I is secured to the wall unistrut or studs. Dual knockouts are present on the sides of the unit for separate input and output conduits external to the wall if needed. An additional hole is provided to prevent inadvertent lifting of the unit from the keyholes. Always consult local codes for structural requirements when mounting the unit. MOUNTING SCREWS UNISTRUT OR WALL STUD DR (Blank) Dimming Relay (Optional) Refer to Page 14 for DR application details. No Dimming Relay option. DIMENSIONS IIS-550-I WIRING LED FLUORESCENT INCANDESCENT DIMMING RELAY BLUE (NORMALLY OPEN) RED (COMMON) BROWN (NORMALLY CLOSED) INPUT LEADS The IIS Inverter utilizes two sets of input leads: one to provide unswitched power to the inverter system and a second to serve as a normal power input to the lighting load. Any switch for the designated emergency circuit will be present on the Normal Power Input leads. For Emergency Operation Only applications, the Normal Input leads are not needed and would remain disconnected and capped. fax: 520.741.2837 INTERNAL CIRCUIT BREAKER The internal circuit breaker protects the inverter from overload on the output side of the unit. Internally, the appropriate voltage lead is selected for connection to the line side of the circuit breaker and the designated emergency load connects to the single Yellow/Violet 120/277V hot lead. The dimming relay leads allow for a dimming signal to operate the luminaires in the desired, dimmed state during normal operation. The IIS inverter will then bypass the dimming control to operate fixtures at full light output in the event of a loss of normal AC power. Additionally, if desired, the dimming leads can be wired to operate the luminaires at a reduced lumen output setting based on the dimmable driver(s) being used during emergency operation. Refer to Page 14 for details. 11 www.iotaengineering.com

UNINTERRUPTIBLE IIS-350-U 350 WATT OPERATES: HID FLUORESCENT LED INCANDESCENT The IOTA Uninterruptible IIS-350-U is a UL Listed stand-alone sine wave output inverter designed to provide power to designated emergency lighting fixtures. In a power loss situation, the IOTA IIS-350-U will supply 350W of power from the onboard battery supply. The double-conversion design of the IIS-350-U delivers power with no interruption to the load, allowing no-break operation of HID, incandescent, LED, and fluorescent lamp and ballast combinations. The IIS-350-UM multi-tap model is available for load voltage applications of 120/208/240/277 volts. The IIS-350-U is available in a surface mount housing and comes with a three-year warranty and seven-year pro rata battery warranty. TECHNICAL SPECIFICATIONS Input Voltage... 120V, 60Hz Input Rating (bulk)... 750 Watts at.65 lagging PF Output Voltage (IIS-350-U)... 120 Volts, 60Hz Output Voltage (IIS-350-UM)... 120/208/240/277 Volts, 60 Hz Output Power... 350 Watts at.9 leading to.9 lagging PF Lamps Operated... HID, LED, Fluorescent, Incandescent Transfer Time... Uninterruptible (no transfer time) Emergency Operation... 90 minutes Voltage Regulation (emergency)... +/- 2% @ 15% to 110% load Frequency Regulation (emergency)... +/-.5% Load Power Factor Range....9 leading to.9 lagging Operating Temp... 20 to 30 C Battery... Valve Regulated Lead Acid (VRLA) Weight...116 lbs. Approval... UL 924 Listed FEATURES Uninterruptible sine wave output Operates HID, LED, fluorescent, and incandescent fixtures Emergency lighting supplied from one convenient source Includes momentary contact test switch, yellow ready indicator, green inverter-on indicator, and red alarm indicator High efficiency pure sine wave inverter Variable-rate, temperature-compensated charger Valve Regulated Lead Acid (VRLA) battery provides long-life and is maintenance free Line voltage allows for remote mounting of emergency fixtures at distances up to 1000 feet Low Battery Voltage Disconnect Line Latch Protection Electronic overload protection Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements Durable 16 gauge steel housing design with white semi-gloss powder-coat paint finish 3/7 Pro-Rata Warranty The IIS-350-U may be used in conjunction with the IOTA ETS Emergency Transfer Switch for some switched LED, fluorescent, and incandescent applications. Visit www.iotaengineering.com for further information. 12 IOTA Engineering tel: 1.800.866.4682

IIS-350-U ORDERING GUIDE Use the Ordering Guide below to determine the Catalog # of the model required for your application. IIS-350 - Surface Mount design for surface or shelf mounting. Keyhole slots at the back of the unit are spaced for secure mounting to the wall s unistrut or studs. After AC supply and fixture leads are routed to the wall location, the IIS-350 is secured to the wall unistrut or studs. Dual knockouts are present on the sides of the unit for separate input and output conduits external to the wall if needed. An additional hole is provided to prevent inadvertent lifting of the unit from the keyholes. Always consult local codes for structural requirements when mounting the unit. MOUNTING SCREWS UNISTRUT OR WALL STUD U Uninterruptible 120 VAC Input 120 VAC Output UM Uninterruptible w/ Multi-tap Output 120 VAC Input 120/208/240/277 VAC Output DIMENSIONS IIS-350 WIRING IIS-350-U IIS-350-UM fax: 520.741.2837 13 www.iotaengineering.com

DIMMING RELAY (-DR) APPLICATION The DR Dimming Relay Option provides additional capability when used with dimming controls. The DR option can be used as either a Dimmer Bypass or to accommodate an EM Dimming Signal. Refer to the descriptions and diagrams below for application details. The Dimming Relay is available as an additional option on select IIS Inverter Models (IIS-125, IIS-375-LED, and IIS-550-I). Add the -DR suffix to specify the Dimming Relay feature. IIS-125-CG IIS-125-SM IIS-375-LED IIS-550-I -DR Add -DR to Model Number when requiring the Dimming Relay feature. Application 1 - Dimmer Bypass The Dimming Relay contacts provide electrical continuity during normal power conditions allowing your dimming signal to operate the luminaire in the desired, dimmed state. When the inverter transfers into the emergency mode, the dimming relay contacts electrically open the 0-10 dimming reference signal forcing the luminaire to operate at full lumen output regardless of dimmer setting (IIS-125 Diagram shown). NORMAL CIRCUIT NORMAL LIGHTING LOAD SELECT PROPER VOLTAGE LEAD AND CAP UNUSED LEAD. BRANCH CIRCUIT EMERGENCY CIRCUIT 277V ALTERNATE AC INPUT 120V GROUND WIRE GREEN INVERTER ORG (277V) OUTPUT LEADS BLK (120V) INPUT LEADS WHT (NEUTRAL) DIMMING RELAY FLYING LEADS LEADS ORG (277V) BLK (120V) WHT (NEU) YELLOW (277V) VIOLET (120V) GRAY (NEUTRAL) BLU (NORMALLY OPEN) RED (COMMON) BRN (NORMALLY CLOSED) DESIGNATED EMERGENCY LOAD OPERATES IN BOTH NORMAL AND EMERGENCY MODES. CIRCUIT MUST BE ISOLATED FROM NORMAL CIRCUITS. VIOLET GRAY VIOLET GRAY DIMMER CONTROL GROUND WIRE - CONNECT FIXTURE SUPPLY GROUND AND UNIT GROUND IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. IF USING A SECONDARY AC INPUT, SELECT PROPER VOLTAGE LEAD AND CAP UNUSED LEAD. USE A 277V RATED SWITCH IF CONNECTING TO 277V INPUT. FLYING LEADS - SELECT PROPER VOLTAGE LEAD AND CAP UNUSED LEAD. CAP UNUSED LEAD. LOCAL SWITCH (IF PRESENT) PRIMARY UNSWITCHED INPUT The Dimming Relay contacts provide electrical continuity during normal power conditions allowing your dimming signal to Application 2 - EM Dimming Signal The Dimming Relay contacts are electrically open during normal power conditions allowing your dimming signal to operate the luminaire in the desired, dimmed state. When the inverter transfers into the emergency mode, the dimming relay contacts electrically short the 0-10 dimming reference signal forcing the luminaire to operate at a reduced lumen output setting based on the dimmable driver being used. Verify operating results of the luminaire with the 0-10 volt reference signal shorted to assure the application and mounting height produce code-compliant egress lighting (IIS-125 Diagram shown). NORMAL CIRCUIT NORMAL LIGHTING LOAD SELECT PROPER VOLTAGE LEAD AND CAP UNUSED LEAD. BRANCH CIRCUIT EMERGENCY CIRCUIT 277V ALTERNATE AC INPUT 120V GREEN ORG (277V) BLK (120V) WHT (NEUTRAL) GROUND WIRE INPUT LEADS INVERTER FLYING LEADS ORG (277V) BLK (120V) WHT (NEU) OUTPUT LEADS DIMMING RELAY LEADS YELLOW (277V) VIOLET (120V) GRAY (NEUTRAL) BLU (NORMALLY OPEN) RED (COMMON) BRN (NORMALLY CLOSED) DESIGNATED EMERGENCY LOAD OPERATES IN BOTH NORMAL AND EMERGENCY MODES. CIRCUIT MUST BE ISOLATED FROM NORMAL CIRCUITS. GRAY VIOLET GRAY VIOLET DIMMER CONTROL GROUND WIRE - CONNECT FIXTURE SUPPLY GROUND AND UNIT GROUND IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. IF USING A SECONDARY AC INPUT, SELECT PROPER VOLTAGE LEAD AND CAP UNUSED LEAD. USE A 277V RATED SWITCH IF CONNECTING TO 277V INPUT. FLYING LEADS - SELECT PROPER VOLTAGE LEAD AND CAP UNUSED LEAD. CAP UNUSED LEAD. LOCAL SWITCH (IF PRESENT) PRIMARY UNSWITCHED INPUT 14 IOTA Engineering tel: 1.800.866.4682

TERMINOLOGY Double Conversion - Double-conversion systems provide current to both the inverter and battery simultaneously. The load is operated from the inverter at all times. When AC power is lost, the inverter continues to operate the load from the battery without interruption. The IIS-350-U and IIS-350-UM utilize double-conversion to provide the load with uninterrupted power, preventing arc loss in HID lamps. Fig. A Fig. A: Double-Conversion Inrush Current - The maximum, instantaneous input current drawn from electrical devices when first turned on. Where inverters are concerned, the design must be capable of handling the draw on the circuit without triggering overcurrent protection features. Leading to Lagging - Leading to Lagging is a measurement of the phase difference between two sinusoidal waves. The phase difference varies depending on the load. The IIS-125, IIS-375-I, and IIS-350-U Inverters are designed for operating loads with a.9 leading to.9 lagging power factor (PF), and IIS-375-LED and IIS-550-I operate loads with.8 leading to.8 lagging PF. Fig. B Fig. B: Leading to Lagging Power Factor Low Battery Voltage Disconnect - The Low Battery Voltage Disconnect is a safeguard that disconnects the battery when battery voltage drops to an insufficient level. Disconnecting the battery prevents damage that could occur to the inverter equipment from a low voltage condition. Line-Latch Protection - The Line-Latch protection feature prevents the battery from prematurely resuming operation after Low Battery Voltage Disconnect. To prevent deep discharge, the battery will not resume emergency operation until AC power has been restored and charged the battery to sufficient levels. Fig. C: Modified Sine Wave Modified Sine Wave - A modified sine wave (sometimes referred to as a simulated sine wave) is an AC current that is not a pure sine wave. Modified sine waves have some load limitations in regard to electronic equipment. Lighting loads, however, are typically unaffected by modified sine wave current. Fig. C Pure Sine Wave - A pure sine wave is indicative of normal AC voltage. There are no load limitations with pure sine wave output. Fig. D Fig. D: Pure Sine Wave MODIFIED SINE WAVE Uninterruptible - An uninterruptible inverter switches power from the normal AC supply to the emergency supply without interruption to the load. HID fixtures require uninterrupted power supplies in order to maintain the electrical arc that lights the lamp. Should power be interrupted to the HID fixture, the lamp will extinguish and require several minutes before returning to adequate illumination levels. VRLA (Valve Regulated Lead Acid) Battery - A VRLA battery is a sealed maintenance-free lead-acid battery. The valve design keeps the battery sealed while allowing the venting of gasses that may be generated by over-charging. fax: 520.741.2837 15 www.iotaengineering.com

IOTA Engineering is dedicated to providing products that meet the standards our customers demand as well as the superior service they deserve. All IOTA products receive 100% quality inspection before shipment to insure proper and satisfactory operation. When operated under normal conditions, IOTA inverter products will provide years of dependable service. Our IIS Series Products are backed by a 3/7 year warranty. The unit is covered by a complete 3-year warranty against defects in material or workmanship, and a 7-year pro-rata battery warranty. If within the duration of the warranty, the product fails to perform satisfactorily within specified limits, IOTA Engineering will test and inspect the product, and repair or replace any IOTA product found to be defective in materials or workmanship free of charge. For additional information on IOTA s IIS Series Unit Inverters and other emergency lighting solutions, visit us at www.iotaengineering.com. Our website features the latest up-to-date information for comparing models, specifying products, or assisting with installation. Our on-line Technical Library puts you one click away from IOTA Specification Sheets and Installation Manuals, in addition to helpful wiring diagrams and application notes all in PDF format for easy printing. Also, check out our What s New section to stay current on the latest in product offerings and design enhancements for your emergency lighting options. Need some additional assistance? You can easily contact your Customer Service Representative via e-mail by visiting our IOTA Contacts page. Bookmark us at www.iotaengineering.com! DISTRIBUTED BY: PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-4682 FAX: (520) 741-2837 www.iotaengineering.com REV 110615 2015 IOTA Engineering. All Rights Reserved.