SmarTemp Control fx 2.0

Similar documents
Coolant Heater Thermo Top (TTC) Heavy-duty Operating Instructions Installation Instructions

Coolant Heater Thermo Top (TTC) Operating Instructions Installation Instructions

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

THX-DL Data Logger USER & INSTALLATION MANUAL V

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Model: Edge-HC. 1 edge-hc

Halton SAFE / 7.14 user guide and installation instructions

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

5 On/Off button 6 Function selector switch 7 Symbol - Eco function 8 Symbol - Standard heating function

Added password for IP setup page : Password must be in IP format!

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

Element. Controller. Manual for use and maintenance. Element. Climate Controller. Ag/MIS/UMGB /17 Rev 1.0 P/N:

Smart thermostat with Humidification/De-humidification control

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS

User Manual. Dryer Controller M720

Pioneer Z100 Smart Thermostat Operating and Installation Manual

CommStat 4 Controller

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

Dryer Controller M720

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

FCD-wire Contents. List of Figures

Model: Available in: Sapphire Black and Glacier White. 1 Series

User Manual 561_U. WiFi Thermostat 561. Introduction 10/16

Thermo 50 Coolant Heater. HMMWV 6.2 and 6.5 Liter Diesel. Table of Contents. Foreword

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Lyric T6 & T6R Smart Thermostat

Pioneer Z100 Smart Thermostat Operating and Installation Manual

CONTENTS. Backup Batteries

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat

Xtralis VESDA LCD Programmer Quick Reference Guide

ZED UV Monitor PRO11DPI-I

Quick start guide. English

Air Top 2000 ST B (Gasoline) Air Top 2000 ST D (Diesel)

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

JOVY SYSTEMS RE User Manual Rev. 1.00

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Smart Temp. Model

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Intelligent Security & Fire Ltd. PX Control Panel. User Manual. Issue C

IDEAL E-NERGY Thermostat Touch type User Manual

ZIP HydroTap G4 Celsius User Guide

Smart Thermostat. User Guide

DC200 Digital Dispenser Operating Manual

EXPERT TRI-STAR. Temperature controller. User s Manual

Model: Available in : Sapphire Black and Glacier White. 1 Series

Med Touch Master Alarm

Blaze INFO-2. Information Display

SAS6000UTK-7 UNIVERSAL THERMOSTAT

Model TZ43. ZWave Thermostat INSTALLATION AND OPERATION MANUAL DCN: /22/08 *** IMPORTANT NOTICE ***

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

Photo 5 Photo 6 Note: Once you connected the dehumidifier to the local network you can install the app on any other mobile phones and use Scan QR key

SmartVent. Digital Controller User Guide Manual. NZ s Home Ventilation Specialists

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

7-Day Electronic Timer Model CDN Operating Instructions

SmartVent. Keypad Controller User Guide Manual. NZ s Home Ventilation Specialists

Follett Performance Plus

Air Top Evo 40 / 55. Air Heater. Installation/Operation Manual

NS (A) ECN

REMOTE CONTROL FOR CHILLER MYCHILLER

Espar. WEB Edition - July. 2012

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions

QS941A Controller User Interface

Wireless Thermostat (WTS10) Keypad Operation Guide

Basic Plus2 Room Thermostats Floor Heating

Sensor Control Panel

Model: Slimline-RF. 1 Slimline Series

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

TV2 Room Pressure Monitor Quick Start Guide

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

2018 thesimple, Inc.

BRS Mechanically-Agitated BioReactor MA 100. Quick Reference Guide Ver2.0

INITIALIZATION / INSTALLATION

BURGLAR ALARM PANEL BS-468

EasyTech.One Temperature Controller for Pellet Burner

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

Installation Guide for. Energate Thermostats. Pioneer release 2.3 and HōlHōm/Foundation release 3.5

USER MANUAL USB Multi-Function Datalogger Model RHT35

Quick Guide for SmartShaker 2

D3000. Installation & Setup Guide

D3D Wi-Fi GSM Smart Alarm System -User Manual

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Thermo 230 / 231 / 300 / 301 / Troubleshooting

THX-DL Data Logger USER & INSTALLATION MANUAL V Refrigeration

ZIP HydroTap G4 User Manual Affix model number label here UK

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL

WIRED REMOTE CONTROLLER

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

On initial power up the thermostat will guide you through set up procedure for the following:

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Application description

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

FAAST LT SET-UP AND TROUBLESHOOTING GUIDE. CONTENTS Introduction...1 Wiring up a FAAST LT unit...1. Setting the Fan speed...7

Tri-Tech Medical Inc.

User & Installer Manual SMT-400 "Enterprise" Wi-Fi Thermostat

CLEVER CONTROL Version: V3

Safety & Installation Instructions

Transcription:

Digital Timer Interface Installation / Operation Instructions General Thank you for choosing Webasto to meet your heating needs. The Webasto SmarTemp Control fx 2.0 enables you to preset start-up cycles of your Webasto heater 7 days a week with 4 individual times each day. Operation The Webasto SmarTemp Control fx 2.0 is controlled using a rotary dial around the outside of the unit to scroll through menu options. Simply click the selection button ( ) to make your choice. The following sections will define each menu item and its default setting. Compatibility All Coolant Heaters; the SmarTemp Control fx 2.0 has an output of 1A for the heaters ON/OFF signal. Heaters requiring a higher amperage signal will require a relay to accommodate different specifications. See electrical connections for details. Note: Relay not included. Mounting Procedure 1. Find a suitable mounting location (on a flat surface if possible) in a visible area. CAUTION: Always install in an area protected from the effects of weather and contamination. 2. Use the drilling dimensions to lightly mark the two mounting holes. 3. (Optional Step) To route wire harness through the mounting surface, drill a 17mm hole as notated on the drilling dimensions image. NOTE: Always make sure there are no obstacles behind the mounting location prior to drilling. 4. Secure the Webasto SmarTemp Control fx 2.0 using the two supplied #4 screws. 5. Apply the supplied Heater Off warning sticker in a highly visible location to the driver s area. Refer to the example sticker below. 6. Observe the Menu Descriptions section for proper menu setup. 1

Electrical Connections SmarTemp Connector Pin-out Pin Number Description Wire Color 1 +12 / 24V Red 2 GND Brown 3 Heater Output Black 4 *Diagnostic Blink Code Green For terminal removal use: Molex terminal removal tool P/N: 11-03-0044 (http://www.molex.com) TERMINAL INSERT SIDE OF CONNECTOR *Diagnostic Blink Code functionality does not apply to most coolant heaters. Refer to the Error Code section for additional information. Relay Connection: (If applicable) Heaters requiring higher amperage ON/OFF signal will require a relay to accommodate different specifications. If the connected heater requires more than a 1A ON/OFF signal to start, use the pin-out of a standard relay as described below. Relay Relay Pin 30 Relay Pin 85 Relay Pin 86 Relay Pin 87 Output Battery (B+) power source (Fused according to required heater amperage) Ground Heater ON/OFF signal wire from pin 3 of SmarTemp Control fx harness. Switched ON/OFF signal to heater. Component Description (Webasto) ON/Off Button Rotary Knob Screw Cap LCD Screen Status Indicator Light(s) Selection Button *Micro USB Service Port * The micro USB service port is not used for heater diagnostic purposes on SmarTemp Control fx 2.0. LCD Screen Legend Mode (Auto or Manual) Auto Mode Manual Mode Current Day Current Day Current Day Day and Time Timer Active Current Time Current Time Auto or Manual Mode Auto Mode Heater ON Manual Mode Heater ON NOTE: When Auto is visible, timers are enabled Runtime Remaining Runtime Remaining 2

Menu Descriptions Definitions Default Mode Two modes are possible: Auto mode enables the pre-defined timer programs. Manual ON/OFF functionality is still possible while in this mode. Manual Mode allows the heater to be operated via the Webasto button on the SmarTemp Control fx 2.0. While in Manual Mode, all Auto Mode functionality is permanently disabled. Note: While in manual mode the heater will continue to operate based on the predefined Duration set by the user. See Duration for further detail. Manual Language Language changes between English, French, and Spanish English Duration Error Code Options Duration allows user to select the heater runtime of the heater. Set range is between 10 120 minutes selectable by 10 minute increments. Note: Duration time for all timers will default to the set duration time. User will have the ability to manually change duration for each timer. This section will log the last 5 error codes and the date that it was set. Highlight and select an error code for a full description. If the heater produces an error code, the status indicator lights will flash red and the error will display on the main screen. Error codes cannot be reset through the Webasto SmarTemp Control fx 2.0 on the heater, a Webasto PC Diagnostics tool is needed. Refer to the heater service manual for resetting an error code. Note: Diagnostics via blink code is not available on all coolant heaters. Error Codes on products with no blink code functionality can still be obtained using the PC Diagnostics test tool. Refer to the applicable service manual by visiting www.techwebasto.com for detailed PC diagnostics information. Advanced Level adjustment; see below 60 minutes No Errors Time & Date Time & Date allows user to properly set the current date and time. User also has the ability to switch between AM/PM and 24 hour format. If the 24 hour format is selected the date format will change to dd/mm/yyyy. Use the rotary knob to choose the time / date and the selection button to confirm each entry. The Webasto button can be used to go back to the previous field if additional changes are needed. AM/PM mm/dd/yyyy Timer There are 4 heater start-up cycles possible 7 days per week. The timer is separated into to three categories. The user can select Mon-Fri, set each specific timer (T1 T4) for a typical work week all at once. A weekend Sat-Sun can be scheduled in the same manner or a full week by using the Mon-Sun selection. The custom link allows the user to set a specific timer (T1 T4) for each individual day. When selecting a specific timer a sub-menu will appear (Edit, Skip, and Off). To change the timer cycle, select edit. Changes are saved immediately. The skip feature allows a timer cycle to be skipped one time within a 7 day period. Timer will reactivate after this one-time skip cycle. Note: To turn a specific timer off permanently select off. 3

Definitions Default LVD Default LVD Low Voltage Disconnect allows the user to adjust the battery voltage level at which the Webasto SmarTemp Control fx 2.0 will shut the heater off. A warning (LED and message) will appear after 8 minutes of low voltage. The warning will remain on for 2 minutes before the heater is shut off. If battery voltage is equal to or less than the threshold selected +0.1v, the heater will not start. i.e. if an 11.5v threshold is selected the heater cannot be started until B+ has reached 11.7v. 12 volt - Range between 11v 12.5v 24 volt - Range between 21v 25.5v Default allows the user to perform a reset to all default values. Note: A power loss will not reset user programmed values. 11.4v 24.2v N/A Password A password can be set to prevent access to the advanced Options menu. Enter a 4 digit code passcode to begin securing the Options menu. Note: This is typically used in fleet vehicle applications. OFF Hour Meter SW Version The hour meter logs the operating hours of an active ON signal to the heater. This does not reflect the true runtime of the heater itself. Note: For warranty purposes a diagnostic printout is still required where applicable. This hour meter is for reference only! This displays the firmware version of the Webasto SmarTemp Control fx 2.0. N/A Installed Version Back Select this to return to the previous screen. N/A IMPORTANT - The Red status indicators (heater "ON") and LCD screen backlight turn off after 30 seconds. A touch of any button or a turn of the rotary knob will re-activate these lights. If the "Webasto" button is used to reactivate these lights, an additional press of this button is necessary to turn the heater off. Note that when the heater is "ON" the display is active. 4

Technical Information - Rated Voltage: 12 / 24V - Operating Voltage Range: 9V - 32V - Low Voltage Disconnect Range: 12V: 11 12.5V 24V: 21 25.5V - Operating Temperature: - 40... +185 F (- 40... +85 C) - NOTE: Display visible to -22 F (-30 C) - Installation Dimensions: (L x H x D) 2.7 x 2.2 x.60 (69.4mm x 55.5mm x 15.2mm) Use this drawing for dimensional reference only! This is NOT a Template! For a Spanish version of this document, scan this QR Code. 5

SmarTemp Control fx Notes: 6

SmarTemp Control fx Notes: 7

Org. 3/2015 Rev. N/A Ver. 1.0 Webasto Thermo & Comfort N.A., Inc. 15083 North Road Fenton, MI 48430 USA Phone: Fax: Email: Internet: 810-593-6000 810-593-6001 info-us@webasto.com http://www.webasto.us http://www.techwebasto.com