OIL FILM DETECTOR (Flame-proof Version) SODL-1600

Similar documents
OIL FILM DETECTOR (Long-distance correspondence Version)

Standard Specifications

Standard Specifications

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

Features. Drop-in type detector

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Series Temperature Controller Instruction Sheet

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

DIGITAL INDICATOR JIR-301-M

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Series Digital Controller Instruction Sheet

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Gas Detection System TOX ALARM DG2000-Garage

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Temperature Controllers

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Carbon Monoxide Transmitter

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Operating Instructions. For. Alarm Control Module. Model SSR 500

Flame Monitors BROCHURE

System 57. An advanced World of intelligent gas detection system management

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

OPTISENS TUR 2000 Technical Datasheet

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Features and Benefits

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Low Temperature Zirconia Oxygen Analyzer

Process & TeMPerATUre UniversAl input DigiTAl MeTers

FIS SMART SENSOR U (Draft 1) June 25, 2001

Touch Screen 1 loop Addressable Fire Alarm Panel

F4 Process Controller Installation and Operation Guide

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 5700 IR Detection of flammable gases and vapours

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

Bionics Instrument. Alarm Handling. Gas Alarm Systems

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Dust Concentration Meter

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Turbimax CUE21 / CUE22

Safety Light Curtains Area Access Control

Laser Collimated Beam Sensor

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

General Specifications

English. Series. Installation and Use Manual

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Sintrol Snifter A2 EX. Manual. Version 1.2.3

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

Dahua 2-inch HDCVI Speed Dome Installation Manual Version Dahua Technology CO., LTD

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

PTE0705 Electric Fence Monitor

INSTRUCTION MANUAL Micro-computer based digital indicating controller

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

CMT MANUAL 6. NMC SENSORS

PRODUCT CONFORMITY CERTIFICATE

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Buzzer Unit. TAN-5000 Series. Operating Manual

Line Smoke Detector LRMX

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

General Specifications

Dräger REGARD -1 Control System

Class 1 laser beam sensor safe for your eyes

Ultrasonic Reflective Sensor

General Specifications

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Laser Distance Sensor Type M Analog-Output

Installation And commissioning manual. Series S Double Beam 1/16

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Key Features. General Description

Dräger Flame 2350 (UV&IR) Flame Detection

System 57. An advanced world of intelligent gas detection system management

E3M-V. Mark Sensor. Applications

GCS-300 No.GCS31E

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Superdew 3. Hygrometer. Operating Instructions

Power Supply Display Module PSDM. Installation and Operation Manual

UDC 700 Universal Digital Controllers and Indicator Specifications

Dräger Polytron 5720 IR Toxic Gas Detection

Analog Transmitter AT1000 AT1

Features and Benefits

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Dräger Flame 2370 (UV&IR) Flame Detection

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Transcription:

OIL FILM DETECTOR (Flame-proof Version) SODL-600 The model SODL-600 is a flame-proof type oil film detector. This model monitors a water surface for the presence of an oil film floating on the surface. The instrument projects a laser beam onto the water surface and measures the differences in the reflection between water and oil. Improved optical design and continuous scanning laser system enable the Model SODL-600 to offer improved oil detection even for non-ideal water surfaces such as those with bubbles present. Features A robust aluminum-cast housing enables a flame-proof structure. Non-contact detection by laser beam. Instrument not affected by water level variations within 0. m range. Scanning laser beam system provides enhanced detection even under difficult surface conditions such as the presence of floating debris, bubbles or curved oil surfaces. Scanning system contains no moving parts reducing power consumption and increasing reliability. Fast signal processing and short pulse cycle of laser beam provides excellent detection ability even on water surfaces with ripples and waves. A single transmitter can control up to two detectors (optional). Specifications Product Name Model Code Explosion-proof Type Measurement Object Measurement Method Sensor Distance Light Source Configuration Ingress Protection Flame-proof Protection Ambient Conditions Sample Temperature Output Output Signals : Oil Film Detector (Flame-proof version) : SODL-600 : System Model Code ; SODL-600 Transmitter Model Code ; SCWM-60-8 Detector Model Code ; SODL-60U : Oil slick floating on water surface or dry surface (floor) : Reflectance of visible light. : 0. m above water or dry surface (floor). : Class R semiconductor laser diode (red) : Detector and transmitter housed in separate enclosures. : Dust and jets-proof IP65 : Flame-proof structure EXD II BT4 Certificate No. TC996 (for transmitter) Certificate No. TC999 (for detector) : Temperature ; -0 50 C Humidity ; 5 95% RH : Non-freezing : Output items ; 4 items (Undermaintenance, Oil alarm, Instrument error, Measurement error) can be allocated to contact contact point or No. -6 points. Power failure shall be always allocated to contact output No. points; 6 Output (c contact), Output -6 (a contacts or b contacts) shall be set at factory. Capacity ; DC 0V, 0.A or less (resistance load)

Digital Communication system Operating Power Power consumption Weight External Dimensions : Based on RS-485 (isolated) -Available Baud rates ;,400/4,800/9,600/9,00/8,400/57,600 bps -Protocol ; MODBUS/RTU -Data length ; 8 bit -Parity ; Select from NONE/ODD/EVEN -Stop bits ; bit -Data Order ; BIG ENDIAN : 00-40 VAC +/- 0%, 50/60 Hz : Approx. 5 VA (normal), approx. 0 VA (max) : Transmitter ; Approx. kg Detector section ; Approx. 7 kg : Transmitter ; Approx. 7 (W) x 5 (D) x 70 (H) mm Detector ; Approx. ø70 x 60 (L) mm Material Surface Finish Electrical Connections Connecting cable lengths : Transmitter ; Aluminum-cast Detector ; Aluminum-cast : Metallic silver : -Transmitter ; Six water-proof cable glands for 7 8mm diameter cable (two cable glands are used and four cable glands are plugged (G/x6)) -Detector ; Four water-proof cable glands for 7-8mm diameter cable (one cable gland is used and three cable glands are plugged (G/ x6)). : Transmitter to detector, power source and digital communication lines; Max 00 m Principle of Operation The reflectance of light from an oil film is greater than that of water. When an oil film is present on a water surface, it generates a "glistening" effect. From this property, the presence of oil can be detected by applying a light beam of constant intensity to the water surface and then measuring the intensity of the reflected light. The detector contains a semiconductor laser diode, a laser scanner and a photodiode light sensor. The light output from the laser tube is scanned across the water surface periodically across the x-y axis. The light that is reflected back by the water surface is captured by a parabolic mirror and focused on to a sensor located at the focal point of the mirror. The signal from the light sensor is processed by the micro electronics in the transmitter. From the processed signal it can be determined whether an oil film is present or not. The transmitter provides output signals indicating the detection status such as contact switching signals, analogue signals etc.. Water Level Height Variation Light Source & Laser Scanner Mirror & Light Sensor Laser Beam Water Surface Reflecting Mirror (Parabolic Section) Light Sensor Water Level Height Variation Water Surface Reflected Light From Water Surface

System Configuration The instrument comprises a detector and transmitter. The detector and transmitter continuously communicate. The raw detection signal and diagnostic information are sent from the detector to the transmitter. The transmitter provides local status display and generates output signals for onward transmission to an external plant control system or external receiving device. The transmitter allows set up of operating parameters such as detection mode and alarm settings etc.. As an option, two detectors can share a single transmitter. In this configuration the transmitter communicates with each detector individually and provides individual alarm and analogue output signals corresponding to each detector. (max 6 contact switching points). Detector Detector AC 00 40V Digital Communication RS 485 Modbus CH DC 4 0mA Transmitter CH DC 4 0mA AC 00 40V Outputs (Max 6 Points) Transmitter Functions () Display The transmitter displays information on calibration, oil film detection status, raw light intensity, selfdiagnostics and error conditions. () Oil Detection Modes The transmitter allows the detector to be set up for particular water surface conditions such as still, smooth surfaces or unstable surfaces with waves and bubbles etc.. The transmitter allows the operator to establish a suitable set up for the particular installation conditions. () Analogue Output Signals A 4~0mA output signal is available representing the light intensity signal. As an additional function, the analogue output can also be set to indicate alarm status of the instrument (oil detection, instrument malfunction). It does this by changing the analyser output to an out of scale value (ma, ma). Thus a single analogue signal can transmit three detection conditions (normal operation with raw intensity signal, instrument malfunction and oil alarm) (4) Output Signals A total of six contact switching signal are available. These can be configured by the operator to represent alarm and self diagnostic information. The available signals are as follows:- -Oil film detection. - Under maintenance (ST-BY mode). - Detection error (water surface detection error, reflected light error, ambient light error). -Instrument malfunction (laser output truoble, internal temperature alarm). - Power failure (open or closed contact available). (5) External Device Communication Digital commuication with external devices is available using MODBUS protocol from the RS485 output signal. (6) Optional Dual Detector Capability It is possible to connect two detectors to a single transmitter enablining the monitoring of two different locations simultaneuosly. (7) Detection History Stored in Memory Detection parameters are stored in memory together with date and time of detection. This data can be recalled by the operator. The historical data can be used to evaulate instrument performance and assist in fine tuning the sensivity set-up etc..

Terminal Connections NO CONTACT 50 5 5 5 54 55 0 9 9 Power Failure Output TRANSMITTER 9 E 60 90 9 60 Detector Under Maintenance Detector, Oil Detection Detector Oil Detection Detector Error Signal Detector Error Signal Detector Output Output Output 4 Output 5 Output 6 4 5 6 7 8 9 40 4 4 4 RS485/ Detector Output Detector Output RS485/ N L E 6 6 70 7 7 7 90 9 E 4 0mA 4 0mA AC IN Earth 6 6 9 90 9 60 6 6 Detector 74 75 76 77 78 79 Digital Output Digital Output Detector Connects to Terminals of Detector 4

Dimensions Unit : mm Transmitter 8 7 94 54 5 64 5 4 M8 Display 4 Keypad 55 7 4 9 Earth terminal Cable entry 50A pipe Cable entry Detector (40) ø70 Detector Cover Cable entry (66.8) 60 Detector body Earth terminal Cable entry ø7 Hood 5

Installation Transmitter Connecting cable between detector and detector (Total cable length including all devices: Max. 00m) Connecting cable between transmitter and detector Detector Detector 0. m Installation Conditions. The detector should be mounted within 0.m to m from the water surface for normal water conditions. Avoid mounting too close to the water surface in order to avoid splashing and potential damage due to immersion during unexpected flooding, heavy rain, etc.. Install the analyzer at a location where the water flows smoothly. Avoid locations where there is turbulence..install the analyzer at the location where the monitoring surface will not be subjected to direct rainfall or direct wind disturbance, because a severely rippled water surface may make it difficult for oil film detection. For such locations, protection against direct rainfall or wind disturbance will be required. 4. Avoid installing the detector in locations where dead leaves or other debris may accumulate on the water surface. These may affect water flow characteristics and cause detection problems. 5. Avoid locations where sunlight may disturb detection. If strong sunlight causes detection problems, move the detector to a shady location or install a sun shade. 6. Install the instrument I a location where vibrations and mechanical shocks are minimized. Secure a space around the analyzer and scaffolding if necessary for a safe and easy access during maintenance. 7. Avoid locations where there is rising mist due to high water temperature. If this is unavoidable, supplying a gentle airflow will effectively clear the vapor away. 8. If using the instrument to monitor liquid leakage on dry surfaces (such as floors etc.), ensure that the surface is level. A sloping surface will not reflect the light from the laser beam correctly and cause detection problems. 6

Product Code SODL600 4 8 0 4 8 Code indicating special specifications Numeric digit: 9 Alphabetic character: Z A B C D 0 4 9 0 4 9 0 A B Transmitter Mounting On a 50A pole Wall or rack mounting Number of Detectors Connected One (Detector ) Two (Detectors and Detector ) Cable Length from Transmitter to Detector * m (standard) 0m 0m 00m Custom specification (max 00m) Cable Length from Detector to Detector * None (in case of only one detector) m 0m 0m 98m Custom specification (max 98m) Alarm contact output(contact output~6)* a contact (0VDC, 0.A) b contact (0VDC, 0.A) a contact (5VAC, A) b contact (5VAC, A) Anti Misting Heater for Detector Glass * None Equipped to Detector only Equipped to Detector only Equipped to both Detectors and Mounting Bracket for Detector For Mounting on 50A pole (Pole available as an option) For Replacement of SODL- * 4 For Replacement of SODL-0 * 4 For Replacement for others * 4 Special * 4 Mounting Bracket for Detector None (in case of only one detector) For mounting on 50A pole (pole available as an option) For Replacement of SODL- * 4 For Replacement of SODL-0 * 4 For Replacement for others * 4 Special * 4 Sun Shade None Equipped to Transmitter Only Markings Standard (Japanese Language) English Language *. The maximum total cable length between transmitter, detector and detector is 00m (i.e. if cable length from detector to detector is 98m then max cable length from transmitter to detector is m. Cable lengths are specified in m increments. Dete *. This is for contact output # to #6. Capacity of the load for contact output # is limited to 0VDC, 0.A. In the case of that supply power could be varied by like large powered instruments, we recommend installing a rely with time at the point receiving the contact output to avoid error alarm. *. An anti-misting heater for the detector glass is recommended. Select "equipped" if the installation location is prone to sudden temperature changes from low to high and/or the location is subject to high humidity. For example a heater would be required if the temperature changes from 0 deg C to 5 deg C within 0 minutes and ambient humidity is 90%. *4. If replacing existing Model SODL- or SODL-0 instruments, it is necessary to check types of existing fitting brackets and also analogue and alarm signals. Changes may be required to accommodate the new instrument - please consult with your local sales office or distributor. Notes :. The instrument operates on multi-voltage supply of 00 to 40 VAC.. Analogue output is 4-0mA.. Order B-50 or ZB- if a mounting pole is required. 4. In the case of replacement project for SODL- with hood for anti-steam or mist, ask the solution. 7

Dimensions Optional Adapter Unit : mm 70 70 5 Holder () Mounting adapter 68 59 Holder stopper Detector 0 4 M8 05 5 6 4.75 00 M6 66.8 70.5 Fixing arm International Operations: DKK-TOA Corporation 9-0, -Chome, Takadanobaba, Shinjuku-ku, Tokyo 69-8648 Japan Tel : +8--0-05 Fax : +8--0-5685 http://www.toadkk.co.jp/english Information and specifications are for a typical system and are subject to change without nofice. Issued on /5/0