SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

Similar documents
FLOOR CONSOLE / UNDER CEILING DUAL type

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CASSETTE type INVERTER MULTI AIR CONDITIONER

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

WALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type )

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

AUXG18LRLB AUXG24LRLB UTG-UKYA-W AOYG18LBCA AOYG24LBCA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

ASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

ASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz)

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS

DESIGN & TECHNICAL MANUAL

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

DESIGN & TECHNICAL MANUAL

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

DESIGN & TECHNICAL MANUAL

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

CME1856W Service Parts

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU9RLQ AOU12RLQ AOU18CL AOU18RL

CME1856W Service Parts

DESIGN & TECHNICAL MANUAL

Digital Inverter 4 series 8 & 10HP

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*R07LGC AO*R09LGC AO*R12LGC AO*R14LGC

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Кондиционеры Mitsubishi Heavy

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units

Parts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com

TECHNICAL DATA & SERVICE MANUAL

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

DESIGN & TECHNICAL MANUAL

SERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

DESIGN & TECHNICAL MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

Spare Parts Catalogue MV1006

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

MDT2 Service Parts. Table of Contents Cabinet Page 2. Condensing System Page 3. Water and Dispensing Page 4. Water and Dispensing Part Numbers Page 5

IMPORTANT SAFETY NOTICE

Ductless Split Air Conditioner

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Parts and Service Manual

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

DESIGN & TECHNICAL MANUAL

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units

EXPLODED VIEWS & PARTS LISTS

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

Single Zone Air Conditioner SVC MANUAL (Exploded View)

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

EXPLODED VIEWS & PARTS LISTS

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

6868 Ardmore Street Houston, Texas Toll Free Phone Fax

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

TABLE OF CONTENTS. Air Conditioner

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

Transcription:

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL AOYA8LALL AOYB8LACL AOYB8LALL AOYA8LALL AOYB8LALL AOYALACL AOYALALL AOYBLACL AOYBLALL AOYALALL AOYBLALL CONTENTS SPECIFICATIONS................... OUTLINE AND DIMENSIONS......... REFRIGERANT SYSTEM DIAGRAM... CIRCUIT DIAGRAM................. PCB CIRCUIT DIAGRAM............. 7 ERROR DISPLAY.................. 7 PARTS (indoor unit)................ 0 PARTS (outdoor unit)............... 0 ACCESSORIES...................

SPECIFICATIONS ELECTRICAL DATA TYPE INDOOR UNIT OUTDOOR UNIT COOLING CAPACITY HEATING CAPACITY POWER SOURCE FREQUENCY RUNNING CURRENT INPUT WATTS COOLING HEATING COOLING HEATING ABYF8LAT, ABYF8LBT AOYA8LA_L 7. A 7. A. kw. kw.0 kw.00 kw 0 V 0 Hz Cool & heat inverter AOYB8LA_L 7. A 7.7 A.70 kw.7 kw E.E.R. COOLING. kw/kw.0 kw/kw COP HEATING. kw/kw. kw/kw MOISTURE REMOVAL AIR CIRCULATION HIGH.0 L/hr 780 m /hr ABYFLAT, ABYFLBT AOYALA_L AOYBLA_L 9.7 A 9.7 A. kw. kw. kw/kw. kw/kw 7.0 kw 8.00 kw 0 V 0 Hz.7 L/hr 980 m /hr 0. A 0. A. kw. kw.0 kw/kw. kw/kw FAN MOTOR POWER SOURCE INDOOR UNIT ( cool / heat ) OUTDOOR UNIT HIGH-SPEED MED-SPEED LOW-SPEED QUIET 0 V,00 /,00 r.p.m. 90 / 90 r.p.m. 800 / 800 r.p.m. 70 / 70 r.p.m. 80 / 80 r.p.m. 0 V,0 /,00 r.p.m.,0 /,0 r.p.m.,000 /,000 r.p.m. 780 / 780 r.p.m.,00 /,00 r.p.m. NOISE LEVEL INDOOR UNIT ( cool / heat ) OUTDOOR UNIT ( cool / heat ) db / db 0 db / 0 db 8 db / 8 db db / db COMPRESSOR AND REFRIGERANT Hermetic type, pole, phase, TYPE DC inverter motor, Rotary DISCRIMINATION PRECHARGED REFRIGERANT DA0AF-NA,0 g REFRIGERANT TYPE R0A R0A Pipe length m,0 g FULL CHARGE 0 m,0 g ADDITIONAL REFRIGERANT 0 g/m DA0AF-0NA WEIGHT (with oil) 9. kg 0.0 kg,700 g,700 g,800 g 0 g/m DIMENSIONS INDOOR UNIT OUTDOOR UNIT H x W x D H x W x D 78 x 790 x 00 mm 99 x 990 x mm 78 x 790 x mm WEIGHT INDOOR UNIT Shipping / Net OUTDOOR UNIT Shipping / Net kg / 0 kg kg / 7 kg 8 kg / kg 009.07.

OUTLINE AND DIMENSIONS INDOOR UNIT Unit : mm 990 99 (rear view) 00 7 00 0 900 00.0.

OUTDOOR UNIT AOY_8LA_L Unit : mm Top view 790 00 Front view 0 7 Side view 0 0 78 Air flow 8 Drain pipe mounting place ( 0) Bottom view - 0mm hole 77 89 008.0.

OUTDOOR UNIT AOY_LA_L Unit : mm Top view 790 Front view 0 7 Side view 0 0 78 Air flow 8 Drain pipe mounting place ( 0) Bottom view - 0mm hole 77 89 008.0.

REFRIGERANT SYSTEM DIAGRAM OUTDOOR UNIT INDOOR UNIT Muffler Muffler -Way valve -Way valve Heat exchanger Heat exchanger Accumulator Compressor Strainer Expansion valve Strainer -Way valve Cool Heat : THERMISTOR (COMPRESSOR TEP.) : THERMISTOR (PIPE TEP.) : THERMISTOR (DISCHARGE TEP.) : THERMISTOR (ROOM TEP.) : THERMISTOR (HEAT EXCHANGER MED TEP.) : THERMISTOR (HEAT EXCHANGER OUT TEP.) : THERMISTOR (OUTDOOR TEP.) Refrigerant pipe diameter ABYF8L_T / AOY_8LA_L Liquid : /" (. mm) Gas : /" (.70 mm) ABYFL_T / AOY_LA_L Liquid : /" (. mm) Gas : /8" (.88 mm) 008.0.

CIRCUIT DIAGRAM INDOOR UNIT STEP MOTOR STEP MOTOR FAN MOTOR F M GREEN / YELLOW 7 8 M M 7 8 BROWN RED ORANGE YELLOW BROWN WHITE BROWN RED ORANGE YELLOW WHITE YELLOW WHITE RED CN0 CN CN CN9 CN0 CN CN7 CN8 CN CN 7 8 7 8 7 8 7 8 F0 CN0 CN0 FUSE.A 0V CONTROLLER PCB ASSY ( MAIN PCB ) POWER SUPPLY PCB ASSY CN0 CN0 E0 E0 CN CN CN CN 7 W0 W0 W0 CN0 CN08 7 RED ORANGE YELLOW WHITE BLUE PURPLE RED WHITE RED WHITE 7 8 7 8 THERMISTOR ( PIPE TEMP. ) THERMISTOR ( ROOM TEMP. ) 7 8 INDICATOR PCB ASSY TERMINAL TO REMOTE CONTROL UNIT ( OPTION ) TERMINAL THERMISTOR ( PIPE TEMPE. ) THERMISTOR ( DISCHARGE PIPE TEMP. ) THERMISTOR ( COMPRESSOR TEMP. ) THERMISTOR ( PIPE - MID. TEMP. ) THERMISTOR ( OUTDOOR TEMP. ) FUSE 0V A TERMINAL WHITE REACTOR YELLOW YELLOW L N ( N ) WHITE RED BROWN BROWN BROWN BROWN RED WHITE GREEN FUSE 0V 0A OUTDOOR UNIT W0 W W W W W CN7 CN7 CN70 CN80 CN0 CN0 W7 W8 W9 CONTROLLER PCB ASSY ( MAIN PCB ) CN7 RED WHITE RED WHITE YELLOW BLUE RED BROWN BLUE ORANGE YELLOW WHITE RED R (R) WHITE S (S) C M C (T) COMPRESSOR F M FAN MOTOR PMV EXPANSION VALVE WV -WAY VALVE GREEN GREEN POWER SOURCE 008.0.

PCB Circuit Diagrams not available at time of publication

ERROR CONTENTS Operation lamp (Green) Timer lamp (Orange) Filter lamp (Red) INDOOR UNIT The lamps show the error contents. : 0.s ON/0.s OFF (Flash) : OFF Operation lamp (Green) times times times times times times times times times times times times times times times times times times times Timer lamp (Orange) times times times times times 7 times 8 times times times times times times times times 8 times times times times times times 7 times 8 times or times Filter lamp (Red) times times times Error contents Serial reverse transfer error at starting up operation Serial reverse transfer error during the operation Serial forward transfer error at starting up operation Serial forward transfer error during the operation Communication error ( Main PCB Display PCB ) Communication error ( Display PCB Main PCB ) Wired remote control abnormal Indoor room temperature sensor error Indoor heat exchanger temperature sensor (middle) error Indoor heat exchanger temperature sensor (inlet) error Float switch operated Outdoor discharge pipe temperature sensor error Outdoor heat exchanger temperature sensor (outlet) error Outdoor temperature sensor error Compressor temperature sensor error -way valve temperature sensor error -way valve temperature sensor error Outdoor heat exchanger temperature sensor (middle) error Indoor manual auto switch abnormal IPM protection CT error Compressor location error Outdoor fan error Connected indoor unit abnormal Outdoor unit computer communication error Indoor fan abnormal 7 times 7 times 7 times 7 times 7 times 8 times 8 times times times times times times or times times 0. second flashing Discharge temperature error Exessive high pressure protection on cooling -way valve abnormal Pressure switch abnormal Compressor temperature error Active filter abnormal PFC circuit error Model appreciation error 008.0.09 7

WIRED REMOTE CONTROL If an error occurs, the following display will be shown. ("EE" will appear in the set room temperature display.) If "CO" appears in the unit number display, there is a remote control error. Refer to the installation instruction sheet included with the remote control. Unit number Error code S U MO T U WE T H F R S A Error code 0 Error contents Serial reverse transfer error Serial forward transfer error Communication error ( Main PCB Display PCB ) 7 Communication error ( Display PCB Main PCB ) 00 0 Wired remote controller abnormal Indoor room temperature sensor error 0 8 09 0C 0 0A d E 9 0 A 7 8 A b F c 0F c b 9 Indoor heat exchanger temperature sensor (middle) error Indoor heat exchanger temperature sensor (inlet) error Float switch operated Outdoor discharge pipe temperature sensor error Outdoor heat exchanger temperature sensor (outlet) error Outdoor temperature sensor error Compressor temperature sensor error -way valve temperature sensor error -way valve temperature sensor error Outdoor heat exchanger temperature sensor (middle) error Indoor manual auto switch abnormal Power supply frequency detection error IPM protection CT error Compressor location error Outdoor fan error Connected indoor unit abnormal Outdoor unit computer communication error Indoor fan abnormal Discharge temperature error Exessive high pressure protection on cooling -way valve abnormal Pressure switch abnormal Compressor temperature error Active filter abnormal PFC circuit error 007.08.0 8

OUTDOOR UNIT Error contents Thermistor malfunction Abnormal discharge temperature Current surge protection CT abnormality Compressor position detection malfunction Fan malfunction PAM voltage abnormality Timer short Compressor temperature protection (permanent stop) PFC surge protection (permanent stop) LED on 0. sec / off 0. sec on on 0. sec / off 0. sec on.0 sec / off.0 sec on 0. sec / off.0 sec on.0 sec / off.0 sec on.0 sec / off 0. sec on.0 sec / off.0 sec on.0 sec / off.0 sec on.0 sec / off.0 sec 008.07.9 9

PARTS INDOOR UNIT 8 Ref. Description Part number LAT LBT 7 Remote Control 9880 9880 Remote Control Holder 900 900 Top Cover 980 980 Arm 9800 9800 Hanger Bracket L 98900 Hanger Bracket R 989008 98900 989008 7 Cosmetic Panel R 980 9808 8 Cosmetic Panel L 9808 980 009.07. 0

INDOOR UNIT Panel assy Insulation C Insulation F Insulation D PCB holder Insulation E Ref. Description Panel Part number LAT LBT 980 987 Side Cover R Assy 99090 Indicator PCB Assy 9707980 Insulation (Panel) A 98700 Insulation (Panel) B 989007 -- Panel Assy (with side cover R) 99078 990907 97079809 98700 989007 99077 009.07.

INDOOR UNIT Grille Ref. Description Part number Air Filter 98709 Grill F (LAT) 9800 Grill F (LBT) 9807 Arm Bracket 998009 Grille Support 98000 Filter Bracket 9807008 009.07.

8 7 INDOOR UNIT Kit (Flap base) 7 9 Part number Ref. Description LAT LBT Kit (Flap Base) 977009 97700 Flap Base 9870 9870 Protect Cover 9800 980 Support Stay 989900 989900 Louver 9800 9807 Bushing B 9800 9800 7 Louver Stopper 9800 9800 8 Louver Rod 989000 98907 9 Motor Rod 98000 9800 009.07.

INDOOR UNIT Flap base sub assy 8 7 0 Ref. Description Part number LAT LBT 9 Bushing 97900 97900 Bushing C 98008 98008 Flap (Upper) F 9880 98809 Kit (Flap Lower) 9770 9770 Step Motor H 9900970 9900970 Louver Link 98009 98009 7 Louver Shaft 98700 98700 8 Louver Link Cover 98800 98800 9 Step Motor-V 990000 990000 0 Motor Base 98000 9807 Motor Rod-A (Step V) 980007 980007 Flap Link-Upper (Step V) 9800 9800 Flap Link-Lower (Step V) 9800 9800 009.07.

INDOOR UNIT Base assy Ref. Description Part number Base Assy 9900 Cap 98007 Base Bracket 98800 008.0.

7 7 78 7 7 INDOOR UNIT Drain pan assy Evaporator 77 7 79 7 77 Ref. Description Part number 7 Kit (Separate Wall A) 970 7 Kit (Separate Wall B) 9780 7 Kit (Drain Pan Assy) 9790 7 Drain Cap 98700 7 Drain Hose Assy 99000 7 Kit (Insulation Flap Base) 9770 77 Kit (Dew Proof Plate) 97700 78 Catch 9909009 79 Pipe Thermistor 9900000 008.07.9

INDOOR UNIT ABYF8L_T Evaporator 8 8 8 ABYFL_T 8 8 8 8 Ref. Description ABYF8L_T Part number ABYFL_T 8 8 Evaporator Assy 90 900 8 Bypass Pipe Assy 9778907 977800 8 8 Distributor Assy 97 97 Coupling Pipe Assy 97088 970899 009.07. 7

INDOOR UNIT Fan motor 9 97 98 9 98 9 9 9 9 9 9 Ref. Description Part number 9 9 Sirocco Fan Assy 98800 9 Casing 98009 9 Casing Cover 9800 9 Fan Motor Assy 90007 9 Rubber 98000 9 Motor Fixing Table 989000 97 Protector 99800 98 Motor Fixture 98900 9 008.0. 8

0 0 0 INDOOR UNIT Control unit 0 0 0 Ref. Description Part number LAT LBT 0 Control Box 98000 98000 0 Control Box Cover Assy 9909700 9909700 0 Controller PCB Assy (8) 970797 970799 0 Controller PCB Assy () 97079 97079 0 Power Supply PCB Assy 9707980 970798 0 Terminal P 90890 90890 0 Terminal P 9700 9700 -- Room Thermistor Assy 97099087 97099087 009.07. 9

PARTS OUTDOOR UNIT 9 7 8 Ref. Description Part number AOY_8LA_L AOY_LA_L Top Panel Assy 909007 909007 Cover (Switch) Assy 90970 90970 Cabinet Assy 980900 980909 Blow Down Grille 908880 908880 Cabinet Right Assy 9090 90908 Fan Ring 908880 908880 7 Grip 90888007 90888007 8 Emblem 900 900 9 Protective Net 990 9007 009.07. 0

OUTDOOR UNIT 7 9 8 0 7 9 0 Ref. Description AOY_8LA_L Part number AOY_LA_L -Way Valve Pulse Motor Valve Assy 9900070 908 99000 9009 7 Condenser Assy 9807 900 Thermistor Spring A Thermistor Holder 78708 9000890 78708 978000 Propeller Fan 9099090 9099090 7 Nut 909000 909000 8 Motor Bracket 9 Separator Assy 908870 9970 9088709 9970 0 Base Assy 9088908 9900 -Way Valve Assy -Way Valve Assy 9970090 9970090 90 9009 8 Expansion Valve Coil 99000709 99000709 Fan Motor 9007 900 Compressor Assy 9709 99707 Thermistor Assy 9900807 9900807 7 Heat Exchanger Thermistor 9900000 9900000 8 Solenoid Coil 9970008 9970000 9 Compressor Thermistor 99000 99000 0 Reactor Assy 99000 99000 -- Outdoor Thermistor 990000 990000 -- Condenser Assy B --- 900 009.07.

OUTDOOR UNIT 7 Ref. Description Part number Inverter PCB Assy (AOYA8) 970770 Inverter PCB Assy (AOYB8) 970770 Inverter PCB Assy (AOYA) 9707708 Inverter PCB Assy (AOYB) Fuse 970777 Fuse Holder 000 Fuse Holder 000 000808 Fuse 0007 Terminal 970870 7 Inverter Case Assy 9900 009.07.

ACCESSORIES INDOOR UNIT Name and Shape Cosmetic Panel-L Q'ty Application Part number 9808 Cosmetic Panel-R 980 Screw (M x 0) 070000907 Installation template For positioning the indoor unit. For under ceiling type. 990700 Hanger bracket (left) For suspending the indoor unit from ceiling. 98900 Hanger bracket- (right) 989008 Anchor bolt (M) Special nut 80900 Spring washer 0700007 Wall bracket For suspending the indoor unit on the wall. 989700 Screw (M x 0) For fixing the wall bracket. 07000707 Coupler heat insulator (large) For indoor side pipe joint. (Large pipe) 9787 Coupler heat insulator (small) For indoor side pipe joint. (Small pipe) 97877 Nylon fastener For fixing the drain hose. 007870 Drain hose 99000 Insulation (drain hose) VT wire Adhesive type 70 x 0 For fixing the drain hose L 80 mm 9900 8000 Remote control For air conditioner operation 9880 Remote control holder Battery For installing remote control on the wall For remote control 900 0008 Screw (M x ) For mounting the remote control holder 070009098 008.0.

OUTDOOR UNIT Name and Shape Drain pipe Q'ty Application Part number For drain piping work. 90090 OPTIONAL PARTS Wired remote control : UTB-YUD (P/N 9079000) 008.0.

080G8