Dual Agent Unit w / Atmospheric Tank 200 Litres DAHR 01

Similar documents
Firefighting Monitors Tunnels Fire Protection Systems. Integrated Fire Safety and Security Solutions

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

Foam Products ENGLISH

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

Twin-Agent Fire Fighting/Securing Systems Specifications

FIRE STOP 200/30. High technology system for first attack of fire with high pressure nebulized water (Water mist) FD 907. Ed.

Safety is more than just being careful: it

Datasheet Automatic Protection System for Vehicle Engine Rooms Model: BPS

MSC Guidelines for Foam Fire Suppression Systems

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Industrial Fire Brigade

Foam Wheeled Extinguisher AB Movable fire extinguishers

Foam Systems U.S. Quick Reference Guide

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

& Fire Extinguisher Training

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

Tel Web: dyayan.com

w w a. m o c. x e r fi. w u

FIRE SUPPRESSION SOLUTIONS

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES

FIRE-FIGHTING POWDERS. John Dowling. Kidde PLC

Mist-Tech Fire Fighting Equipment

WATER POWERED OSCILLATING MONITOR

DATASHEET HIGH VOLUME LONG RANGE FOAM MONITOR GPM

Firefighting Group Water Systems. 1. Spray Nozzle 2. Fire Hose Box and Fire Hose Box 3. Barrel Fire Hydrant 4. Water Monitor

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

Kelsow Work Instruction. Buffalo Venture FPSO Fire Protection Systems

Firefighting. It is the temperature at which a substance will continue to burn, when ignited.

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

Design and Supply of Fire Equipments. External Fire Fighting Systems.

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

GENERAL SPECIFICATION SAFETY

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

Employers Responsibilities

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

Institute for Plasma Research Welcomes you all on

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

Airport Firefighter Recertification Core Competency Task Book

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

Film Forming Fluoro-Protein Foam Extinguishing Agent

Installation & Operation Instructions Nr _EN_Manual

PRESTO DRY POWDER FIRE EXTINGUISHERS - AB:E

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30

TYPES OF EXTINGUISHING AGENTS

Foam Products. Quick Reference Guide EMEA. Trusted above all.

RIM SEAL SYSTEMS E-BOOK

ONE SEVEN FAST. EFFECTIVE. SAFE. ENVIRONMENTALLY FRIENDLY

FIREWORLD DRY POWDER ABE FIRE EXTINGUISHERS

OUT CARBON DIOXIDE (CO2) EXTINGUISHER Certified & Approved to AS/NZS Lightweight Aluminium Cylinder. AS High pressure hose assembly with

SUPPRESSION SALES I INSTALLATION I SERVICE

Rapid Entry System KNOX BOX INFORMATION PACKET. Exeter Township Fire Department Office of Fire Codes

Innovative Firefighting Products and Systems

SECURITY BLANKET Foam Fire Protection Products

LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM

TECHNICAL MANUAL OPERATOR S, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL IINCLUDING REPAIR PARTS AND SPECIAL TOOLS LISTI FOR


Operation Refilling and Maintenance Manual SFS-10. Hatsuta Seisakusho Co. Ltd. SFS-10-E1404-(A-012)

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

GW MisteryHood Twin Nozzle System. Installation Guidelines. & Applications

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

CERTIFICATE 97/23/EC. Steel grade DC 04. Powder coated with RAL Plastic lining

FLAT FLAME AND EXCESS AIR BURNERS

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

Operation Manual/ Spare Parts List High Pressure Fire Extinguisher OERTZEN HDL 170 S HDL 200

To understand FIRE and how to EXTINGUISH it, we first need to know: What is FIRE?

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers

SPECIALIST IN FIRE SAFETY PRODUCTS PRODUCT GUIDE

Extinguishers. Commercial Industrial High rise buildings

Refrigerant Recovery Machine. Model No Operating Manual

Transforming Challenges with Expertise. Total Protection. from concept to commissioning

MONITORS FOR FIRE-FIGHTING.

Fire protection solutions for ships and offshore facilities

TABLE OF CONTENTS. Fire suppression systems. Sprinkler systems. Foam fire suppression systems. Localised Suppression systems SYSTEMS

Element C3.4 Fire Fighting Equipment

Industrial Health Safety & Environmental Services. Preparation Prevention & Project Solutions

Explosion Protection Engineering Principles

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

POLY extinguishing systems. The high-performance, unique, and versatile extinguishing system for initial, effective fire fighting.

A safe journey with Dräger CRUISE CATALOGUE

Fire protection on chemical manufacturing sites

FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION, TESTING AND MAINTENANCE APPLICATION SPECIFICATION

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

TECHNICAL DATA 3% AR-AFFF

SAFETY AND FIRE PROTECTION

INSTALLATION INSTRUCTIONS. Anti Knocking System, AKR 3. Document no.: A SW version:

TECHNICAL AND USER REQUIREMENTS FOR FIRE-FIGHTING PRESSURE HOSES FOR FIRE-FIGHTING PUMPS

Transcription:

DAHR-01 DUAL AGENT UNIT WITH LOCAL INTEGRATED FOAM TANK Standard Material: : SST AISI 316, painted externally Dry chemical tank: SST AISI 316 Foam Tank: SST AISI 316 Firewater Piping: Titanium gr. 2 Firewater Valves: Titanium gr. 2 Foam piping & valves: SST AISI 316 Dry chemical piping& valves: SST AISI 316 Hose reel: SST AISI 316 Nozzle: Bronze

Hose: Codan 5300 (1 ) and 5400 (1¼ ) Hand Crank: SST AISI 316 Foam Inductor *: Titanium Foam pipe and valves: SST AISI 316 * Foam induction 1% or 3% per project requirements Installation: Mount: Bolted to deck Operation: Activate dry chemical unit by opening N2 release valve which is pressurizing dry chemical tank. Open water valve and foam valve. When dry chemical tank is pressurized (after approx. 10 seconds) open dry chemical valve. Pull out hose to required length, and operate dry chemical handle and water/foam handle on nozzle carefully as required. The dry chemical gives a quick knock down of the fire, and the water/afff foam mix provides cooling and a sealing surface to prevent re-ignition. Be aware of the nozzle reaction forces! Options: Water Piping & Valves: Aluminium Bronze / Cunifer 90/10 Super Duplex Stainless Steel Pressure Indicators: : Project Preference Insulation Heater (Zone 1 Certified) Max working pressure powder tank: Working pressure hose reel water part: Test pressure powder tank: Test Pressure hose reel: 18 barg 20 Bar 33 barg 30 barg

Table 1: DAHR 01 Dimension and Weight Description Type Hose size & length DA Unit w/atmospheric AFFF tank DAHR- 01 1 x 30 m (powder) 1 ¼ x 30 m (premix) Length (mm) Height (mm) Depth (mm) Dry Weight (kg) * 2000 1500 1200 890 * Weight includes charged N2 cylinders, but not powder, AFFF or seawater.

System Logic drawing

Dual Agent Units are manually operated units, discharging dry chemical powder and water/foam, intending to be used by trained firefighting personnel. These Units are extremely efficient units for protection of areas with a risk of hydrocarbons or alcohol fires, such as helicopter decks and process areas. The Dual Agent hose reels are supplied with two individual hoses, where one hose is flowing dry chemical and the other is flowing water/foam. The hoses are connected to a common nozzle, giving individual control of the two agents. Dual Agent Units are rapidly activated, and they are simple to use. The dry chemical powder gives a rapid knockdown of large scale fires, while water/foam gives cooling of hot surfaces and sealing of liquid pool fires. The Dual Agent Units must be installed in the vicinity of the area they are to protect. Technical Description FPE has developed a range of Dual Agent Units, installed in heated and insulated stainless steel cabinets. The standard FPE Dual Agent Unit consists of the following main components: Hose reel Dual agent nozzle Dry chemical system, with N2 expellant Foam system Firewater inlet piping The dual agent unit provides two different fire extinguishing agents: The hose reel is equipped with two hoses, where one flows a mixture of water and foam, and the other flows dry chemical powder. The hose reel is equipped with a dual agent nozzle that has individual open/shut valves for the two agents, and with a twist-action selection of jet or fog on the water/foam side.

DAHR 01Foam System The selection of type of foam, and the mixing ratio of foam/water, is based on the standard on the platform. This Unit is made to connect to the platform firewater ring main system via a standard flange connection. The unit has a 32 mm (1 ¼ inch) hose for supply of foam/water as the standard. Foam is provided from a built-in atmospheric foam tank. The correct mixing of foam is achieved through an in-line inductor. Dry Chemical System The dry chemical system consists of a storage tank for powder and an N2 expellant gas cylinder. A manual release valve is installed on the N2 cylinder valve. The tank is charged with 250 kg of powder. When the manual release valve is operated, N2 will pressurize the dry chemical system quickly, giving an initial shock of the dry chemical and functioning as an expellant during discharge. The tank is equipped with a pressure safety valve, a fill cap and a pressure indicator. The dry chemical inlet to the hose reel is equipped with an isolation ball valve, designed for use with dry powder. The dry chemical system on all models is identical, and is designed to provide a flow of 2,5 kg powder per second, effective for approx. 100 seconds. The dry chemical hose on the hose reel is 25 mm (1 inch). Flow Capacity The flow for water/foam is given in the table below: Model DAHR01 Inlet pressure, (Barg) Flow 6 198 8 229 10 255 Flows are given in Liter per Minute (Lpm)