B OILER MAG XT. 2 flanged - COD flanged - COD flanged - COD flanged - COD flanged - COD.

Size: px
Start display at page:

Download "B OILER MAG XT. 2 flanged - COD flanged - COD flanged - COD flanged - COD flanged - COD."

Transcription

1 B OILER MAG XT Magnetic filters for heating systems of medium-large dimensions. 2 flanged - COD flanged - COD flanged - COD flanged - COD flanged - COD TECHNICAL FEATURES XT 2" XT 3" XT 4" XT 6" XT 8" CONNECTIONS 2" 3" 4" 6" 8" FILTRATION 1000 µm 1000 µm 1000 µm 1000 µm 1000 µm PN max 12 bar max 12 bar max 12 bar max 12 bar max 12 bar TEMPERATURE C C C C C FLOW RATE 20 m 3 /h 55 m 3 /h 85 m 3 /h 110 m 3 /h 140 m 3 /h DIMENSIONS H: 225 mm L: 260 mm ø: 170 mm H: 280 mm L: 360 mm ø: 220 mm H: 280 mm L: 360 mm ø: 220 mm H: 365 mm L: 470 mm ø: 325 mm H: 365 mm L: 525 mm ø: 325 mm PERFORMANCE MAGNETE MATERIAL EXTERNAL SUPERFICIAL FINISHING SEAL 9000 Gauss with high resistance Neodymium Iron Boron (NdFeB) powder-coated, black O-ring in viton MATERIALS BODY stainless steel 304 MAGNET GROUP OF THE TUBE stainless steel 316 grades aerospace quality EXTERNAL SUPERFICIAL FINISHING powder-coated, black SEAL O-ring in viton ADVANTAGES Reinforced polyamide body Neodymium magnet Used as additives loading BENEFITS Holds all impurities and debris of ferrous and not ferrous nature present inside the water Extension of boiler and circulator life MAIN FEATURES Magnetic filters Manta BoilerMag XT prevent black sludge formation (containing iron oxide), inside heating systems. Compatible with pipes of 1 ½ may be used in residential, commercial or industrial properties. Iron oxide reduces the thermal efficiency of heating systems and may seriously damage the boiler. The installation of BoilerMag XT, assures the protection of heating systems, guarantees a higher operation and extends system efficiency. BoilerMag XT Manta filters efficiently remove both magnetic and non-magnetic debris, leaving the heating system free from any contaminations and preventing their formation. Easy cleaning and installation. Patented magnetic core for the removal of iron oxides, magnetite and other debris.

2 APPLICATION AND USE To be installed in any domestic/civil heating circuit of small-medium dimensions. WHAT DO I NEED FOR THE INSTALLATION Typical plumber tool for connections of different type. CORRECT INSTALLATION For better performances, the device has to be installed as follow: 1. Identify a suitable location (see Where to Install p3). 2. Ensure enough clearance to carry out cleaning as the rods must be lifted out of the unit to clean. See dimensions in column B in the table below. 3. Mark and then cut out the correct length of pipe section to be removed to accommodate the BoilerMagXT unit and isolation valves. Ensure the cut is level and burr free. (Isolation valves are not included in the BoilerMagXT pack.) 4. Install appropriate isolation valves to the pipework and fit the valves to the two PN16 flanges (see below for flange dimensions). 5. Position the BoilerMagXT in place then align and secure the fittings to connect the unit to the valves. 6. Open the isolation valves and turn on the heating system 7. Complete the BoilerMagXT warranty card and return to Eclipse Magnetics. 8. Run the heating system at normal operating temperature and check installation integrity INSTALLATION DETAILS A B (mm) C (mm) 2"

3 FLANGE DETAILS PACKAGE CONTENT BoilerMag XT filter Opening/closing and magnet cleaning key Installation user s guide MAINTENANCE To maintain optimum efficiency we recommend cleaning annually. However when a BoilerMagXT is fitted to an existing heating system we recommend more regular checks as it is likely there will be a large build-up of ferrous oxide (black sludge) to clear out. 1. Switch off the heating system. 2. Isolate the heating system and close the isolation valves on either side of the BoilerMagXT unit. 3. Remove the black tricone positioned on the lid.

4 4. Lift out the magnetic cores using the handle on top of the unit. *Warning see below*. Be careful not to place the cores on or near ferrous items. Either place a bucket underneath or connect a hose to the 1 ¼ drain valve on the underside of the BoilerMagXT. Remove the drain plug and open the drain valve. 5. Partially open the inlet isolation valve and allow the contents to drain through the drain valve. When the draining water runs clear turn off the inlet isolation valve and allow the remaining contents to drain. 6. Close the drain valve and replace the plug. 7. Replace the magnetic core and hand tighten the black tricone to retain. 8. Re-open both isolation valves. If required open the vent shown on the top of the unit to release any trapped air.

5 TO BE USED WITH 1. BP 3 IN 1 COD BP L - COD BP L - COD BP 700A 1 L - COD BP L - COD OFFER DESCRIPTION Magnetic filters Manta BoilerMag XT prevent black sludge formation (containing iron oxide), inside heating systems. Compatible with pipes of 1 ½ may be used in residential, commercial or industrial properties. Iron oxide reduces the thermal efficiency of heating systems and may seriously damage the boiler. The installation of BoilerMag XT, assures the protection of heating systems, guarantees a higher operation and extends system efficiency. BoilerMag XT Manta filters efficiently remove both magnetic and non-magnetic debris, leaving the heating system free from any contaminations and preventing their formation. Easy cleaning and installation. Patented magnetic core for the removal of iron oxides, magnetite and other debris. COMPLIANCE This device is in compliance with Regulation UNI 8065 concerning heating systems for civil uses and Regulation UNI 9182 concerning planning, installation and test of supply systems of hot and cold water. ORIGIN OF THE PRODUCT Made in England DS Date of issue: 26/05/2017 Date of revision: Boiler Performance by Manta Ecologica S.r.l. Viale Archimede, Zevio (VR)

Installation and Servicing Instructions

Installation and Servicing Instructions Installation and Servicing Instructions 2 BoilerMagXT Heating & Cooling System Filter Thank you for choosing BoilerMagXT, please follow the instructions carefully to ensure that this BoilerMagXT magnetic

More information

For commercial & industrial systems. Large volume dirt collection capacity

For commercial & industrial systems. Large volume dirt collection capacity For commercial & industrial systems Large volume dirt collection capacity Heating & Cooling System Protection Maintaining system efficiency and reliability in larger properties is a major challenge for

More information

PRODUCT GUIDE. High performance heating system filter Improves energy efficiency Captures magnetic and nonmagnetic.

PRODUCT GUIDE. High performance heating system filter Improves energy efficiency Captures magnetic and nonmagnetic. PRODUCT GUIDE High performance heating system filter Improves energy efficiency Captures magnetic and nonmagnetic debris No block design Fits in Minutes, Protects for Years Black ferrous oxide or sludge

More information

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3 FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3 ACID CONDENSATE NEUTRALISERS NEUTRAL COND / NEUTRAL MINI FDM SLUDGE FILTERS The FDM sludge

More information

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator Operating Instructions Boilermag XL Filter High Intensity Magnetic Separator Technical data is subject to change without notice due to technical innovation! Eclipse Magnetics Ltd Atlas Way, Atlas North,

More information

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function

More information

MAIN FEATURES ADVANTAGES BENEFITS BOSS TRANSFORMER COMBI HF 110 CHEMICAL AND PHYSICAL FEATURES PACKAGING FEATURES

MAIN FEATURES ADVANTAGES BENEFITS BOSS TRANSFORMER COMBI HF 110 CHEMICAL AND PHYSICAL FEATURES PACKAGING FEATURES BOSS TRANSFORMER COMBI HF 110 Power flushing pump with antacid vertical axis. Suitable for domestic and medium dimensions systems. Practical trolley design with 110 litres tank. COD. 301301006 CHEMICAL

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation

More information

Installation and servicing instructions

Installation and servicing instructions Installation and servicing instructions Installation MagnaClean Professional is suitable for all central heating systems and can be fitted anywhere on the main circuit. However, in order to achieve the

More information

DIRTCAL - DIRTMAG dirt separator

DIRTCAL - DIRTMAG dirt separator 864.07 www.caleffi.com DIRTCAL - DIRTMAG dirt separator Copyright 206 Caleffi 5462-546 -5465-5465M - NA5465 - NA5465M Series Installation, commissioning and servicing instructions Function In heating and

More information

DEFENDER DEFENDER. Models: MD22A OPERATION MANUAL. Full Flow Magnetic Filter

DEFENDER DEFENDER. Models: MD22A OPERATION MANUAL. Full Flow Magnetic Filter OPERATION MANUAL Y NT Y YEA Full Flow Magnetic Filter YEA RW ARRA NT DEFENDER FullFlow Flow Magnetic Full Magnetic FilterFilter DEFENDER Models: MD22A 5 5 RW ARRA In the SALUS MD22A box: INTRODUCTION Today,

More information

Greenstar System Filter

Greenstar System Filter Installation and Servicing Instructions Greenstar System Filter For sealed and open vented central heating systems with 22 or 28mm central heating pipes 672087500-00.Wo UK/IE 6 720 87 500 (205/07) Contents

More information

Pulldown Kitchen Faucet

Pulldown Kitchen Faucet P25200 1 of 7 Thank You For Choosing Kallista We appreciate your commitment to Kallista quality products. Please take a moment to review this manual before you install your Kallista product. If you encounter

More information

Commercial product range

Commercial product range Commercial product range 1 Commercial Installer Brochure A4_COVER.indd 1 21/09/2017 15:21 Whether it s marketing leading filters or award-winning chemicals, we design and manufacture effective solutions

More information

Eliminator TotalGuard Installation Manual

Eliminator TotalGuard Installation Manual Eliminator TotalGuard Installation Manual Central Heating Filter Version 2 January 2016 IMPORTANT Please retain these instructions for reference during servicing Page 1 Eliminator TotalGuard Instructions

More information

Entertainment Faucet with Remote Valve

Entertainment Faucet with Remote Valve P25205 1 of 7 Thank You For Choosing Kallista We appreciate your commitment to Kallista quality products. Please take a moment to review this manual before you install your Kallista product. If you encounter

More information

Beautifully Traditional

Beautifully Traditional TECHNICAL DETAILS For full technical details on all our products, please visit our website INSTALLATION INSTRUCTIONS E 1 INSTALLATION INSTRUCTIONS DIMENSIONS Please read these instructions carefully and

More information

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES IMPORTANT: To ensure this product is installed properly, you must read and follow these guidelines. The owner/user of this product must keep this information for future reference. This product must be

More information

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800 P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800 2018 1 of 7 KALLISTA THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment to KALLISTA quality

More information

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS 5400-5500 SERIES INTERCEPTORS 5401 75 4NH 5500 50 3IPS INSTALLATION Place the Wade interceptor downstream of the drain which will supply the oil laden

More information

GRANT CONDENSING OIL BOILER RANGE. Internal and external oil-fired condensing boilers with outputs from 12kW to 70kW

GRANT CONDENSING OIL BOILER RANGE. Internal and external oil-fired condensing boilers with outputs from 12kW to 70kW GRANT CONDENSING OIL BOILER RANGE and external oil-fired condensing boilers with outputs from 12kW to 70kW Grant Vortex Condensing Indoor Range Grant Vortex Kitchen/Utility Models Grant Vortex 15-21 Kitchen/Utility

More information

Davies Carries Parts for MF & SF Series Glycol Feeders

Davies Carries Parts for MF & SF Series Glycol Feeders Chemical Bypass Feeders B24 Feeders Delivers chemicals to any closed loop system. Maintaining a chemically balanced hydronic system has never been easier Allows for safe and easy chemical dosing. Ball

More information

Mounting 4000 and Appliances with Telescoping Rails

Mounting 4000 and Appliances with Telescoping Rails Mounting 4000 and 12000 Appliances with Telescoping Rails Safety Information for Telescoping Rails The telescoping rails are certified by Check Point to use with these models: Check Point 4200 Check Point

More information

Selection of products for BOILER

Selection of products for BOILER Selection of products for BOILER 2018 1 Ferrari s.r.l. statements that have been made to perfection according to current regulations. The good response of the materials to the expressly indicated uses

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION The renewed ETN-Lined pumps are singlestage, magnetic driven, centrifugal pumps in closecoupled execution. ETN-Lined pumps are available both inpp+gf and ETFE. The pump casing is

More information

The widest range of power flushing pumps on the market, designed for restoring and cleaning of

The widest range of power flushing pumps on the market, designed for restoring and cleaning of POWER FLUSHING PUMPS ADVANTAGES THE WIDEST RANGE ON THE MARKET ACIDPROOF PUMPS HIGH FLOW RATES AND S MODULAR AND ALSO EQUIPABLE IN RETROFIT The widest range of power flushing pumps on the market, designed

More information

Composite under-boiler dirt separator with magnet DIRTMAG

Composite under-boiler dirt separator with magnet DIRTMAG omposite under-boiler dirt separator with magnet IRTMG 55-55 - 55 series 07/7 G REITE ISO 900 FM 65 replaces dp 07/6 G Function The IRTMGSLIM dirt separator separates off the impurities contained in air-conditioning

More information

Basin Set INSTALLATION INSTRUCTIONS

Basin Set INSTALLATION INSTRUCTIONS P24130-CR, P24130-LV, P24131-CR, P24131-LV, P24400-CR, P24400-LV, P24401-CR, P24401-LV, P24402-CR, P24402-LV, P24500-LV, P24500-TT 1 of 5 INSTALLATION INSTRUCTIONS Thank You For Choosing Kallista We appreciate

More information

Beautifully Traditional

Beautifully Traditional TECHNICAL DETAILS For full technical details on all our products, please visit our website G Please read these instructions carefully and keep in a safe place for further reference. DIMENSIONS General

More information

CALEFFI. dirt separator series 01137/16 NA. Replaces 01137/15 NA. Product range. Technical specifications

CALEFFI. dirt separator series 01137/16 NA. Replaces 01137/15 NA. Product range. Technical specifications dirt separator 56 56 565 series REIE ISO 900 M 65 ISO 900 No. 000 LEI 07/6 N Replaces 07/5 N unction In heating and air conditioning control systems, the circulation of water containing impurities may

More information

Beautifully Traditional

Beautifully Traditional TECHNICAL DETAILS For full technical details on all our products, please visit our website Arcade single lever basin mixer without pop up waste Arcade dual lever basin mixer without pop up waste Arcade

More information

Single-Control Lavatory Faucet

Single-Control Lavatory Faucet P22740 P23201 P24407 1 of 5 Thank You For Choosing KALLISTA We appreciate your commitment to KALLISTA quality products. Please take a moment to review this manual before you install your KALLISTA product.

More information

CalMag Heating Pack Installation Instructions

CalMag Heating Pack Installation Instructions Calming troubled waters CalMag Heating Pack Installation Instructions Heating Filter Corrosion Inhibitor Scale Inhibitor (if applicable) Cleanser Acidic Neutraliser CalMag HF2 Filter Installation Instructions

More information

Beautifully Traditional

Beautifully Traditional TECHNICAL DETAILS For full technical details on all our products, please visit our website D 1 DIMENSIONS Please read these instructions carefully and keep in a safe place for further reference. Ø36 General

More information

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)

More information

Pear Kitchen Sink Tap

Pear Kitchen Sink Tap Pear Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading

More information

2018 PLUMBING AND HYDRONICS CATALOG

2018 PLUMBING AND HYDRONICS CATALOG 2018 PLUMBING AND HYDRONICS CATALOG COMPANY INFORMATION 1 HYDRAULIC SEPARATORS 2 AIR AND DIRT SEPARATORS AND AIR VENTS 3 THERMOSTATIC RADIATOR VALVES 4 ZONE VALVES AND ZONE CONTROLS 5 DISTRIBUTION MANIFOLDS

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS SECTION 23 22 23 - STEAM CONDENSATE PUMPS PART I - GENERAL 1.1 SECTION INCLUDES A. Steam Condensate Return Units, Gravity Return Type 1. Receiver 2. Pumps 3. Control Panel 4. Accessories Note to PSC: Although

More information

High Pressure Manways CODAP 2000 & PED 96/23/CE

High Pressure Manways CODAP 2000 & PED 96/23/CE High Pressure Manways CODAP 2000 & PED 96/23/CE Alchem offer a range of High-Pressure manways designed and built to comply with the European Pressure Directive 97/23/CE and also with the pressure vessel

More information

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

Beautifully Traditional

Beautifully Traditional TECHNICAL DETAILS For full technical details on all our products, please visit our website Arcade bath shower mixer - deck mounted with brass handle handset Arcade bath shower mixer - wall mounted with

More information

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28 IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28 In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility should

More information

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology Zeparo Cyclone Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology IMI PNEUMATEX / Air Vents, Dirt Separators and Degassing / Zeparo Cyclone Zeparo Cyclone Comprehensive

More information

Installation guide Sahara & Sahara Plus

Installation guide Sahara & Sahara Plus Installation guide Sahara & Sahara Plus Installation requirements. Components for Billi Sahara 310, 320, 360 & 3120 Models Before commencing installation, ensure you have identified the following. 1. Underbench

More information

Automag. Self-purging, fully automated magnetic filter

Automag. Self-purging, fully automated magnetic filter Automag Self-purging, fully automated magnetic filter The benefits of automated magnetic filtration No consumables required Automag only requires small amounts of compressed air, which powers the process.

More information

REVE ORDERING INFORMATION NOTES T01-E INSTALLATION INSTRUCTIONS ELONGATED TWO-PIECE TOILET K-17178T-S2/K-17178T-SBG2/K-17178T-SP2

REVE ORDERING INFORMATION NOTES T01-E INSTALLATION INSTRUCTIONS ELONGATED TWO-PIECE TOILET K-17178T-S2/K-17178T-SBG2/K-17178T-SP2 REVE INSTALLATION INSTRUCTIONS ELONGATED TWO-PIECE TOILET K-17178T-S2/K-17178T-SBG2/K-17178T-SP2 Please read these instructions carefully to familiarize yourself with the required tools, materials, and

More information

PLC Control Touch-Screen

PLC Control Touch-Screen Almost all laboratory freeze-drying processes can be carried out using this basic unit and the wide range of accessories available. The 4K incorporates a stainless steel cooled trap that can be easily

More information

Floor Standing Bath Shower Mixer. Fitting instructions. Please keep these instructions for future reference and request of replacement parts.

Floor Standing Bath Shower Mixer. Fitting instructions. Please keep these instructions for future reference and request of replacement parts. Floor Standing Bath Shower Mixer Fitting instructions Please keep these instructions for future reference and request of replacement parts. We have taken great care to ensure that this product reaches

More information

REVE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP

REVE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP REVE INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation

More information

INTA ION MODERN BAR / BATH SHOWER MIXER CP

INTA ION MODERN BAR / BATH SHOWER MIXER CP INTA ION MODERN BAR / BATH SHOWER MIXER 910000CP INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER Page 1 of 10 INTRODUCTION This installation guide has

More information

Spare Parts Catalogue RC411

Spare Parts Catalogue RC411 Spare Parts Catalogue RC411 1 - Hood 2 - Tank 3 - Handle 4 - Wash and rinse column 5 - Rinse 6 - Wash arm 7 - Pump 8 - Control box 9 - Detergent dispenser 10 - Rinse aid injector 11 - Drain pump kit 1

More information

EEMAX SERIES-TWO WATER HEATERS

EEMAX SERIES-TWO WATER HEATERS EEMAX SERIES-TWO WATER HEATERS ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL MODELS COVERED:- EX190 TC, T2-240/208 V EX144 TC, T2-240/208 V EX1608 TC, T2 208V EX160 TC, T2-277

More information

Target Monobloc Kitchen Mixer Chrome

Target Monobloc Kitchen Mixer Chrome Target Monobloc Kitchen Mixer Chrome Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan,

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION Thermostatic Mixer Shower System NOTICE The instruction manual includes part lists, installation instructions, usage of thermostatic and suitable inlet system. Make sure the installation

More information

CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions (1) (2) PLEASE READ BEFORE INSTALLATION

CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions (1) (2) PLEASE READ BEFORE INSTALLATION CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions INTRODUCTION This guide provides instruction for the installation operation and maintenance of concealed touch control

More information

FT14 Ball Float Steam Trap (Screwed)

FT14 Ball Float Steam Trap (Screwed) Page 1 of TI-S02-0 ST Issue 9 Cert. No. LRQ 096008 ISO 9001 FT14 Ball Float Steam Trap (Screwed) Description The FT14 is an SG iron bodied ball float steam trap having stainless steel working internals

More information

Dimensions: 39 1/2" w x 22" D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink,

Dimensions: 39 1/2 w x 22 D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink, Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot), Putty knife Plumber's putty Pipe wrench Channel-lock pliers

More information

CALEFFI. SEP4 combination hydraulic, air, dirt and magnetic separator series 01249/13.1 NA. Replaces 01249/13 NA. Function.

CALEFFI. SEP4 combination hydraulic, air, dirt and magnetic separator series 01249/13.1 NA. Replaces 01249/13 NA. Function. SEP4 combination hydraulic, air, dirt and magnetic separator 5495 series CCREDITED ISO 9001 FM 21654 ISO 9001 No. 0003 CLEFFI 01249/13.1 N Replaces 01249/13 N Product range Function combination hydraulic,

More information

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2 BLADE BATH MIXER DECK MOUNTED CHR WITH KIT 20007014600 INSTRUCTIONS P5-65511339-1-BS-E A/2 20007014600 INTRODUCTION DIMENSIONS Please read these instructions carefully and keep in a safe place for future

More information

MemoirsStately3HoleBasin Mixer Installation and User Guide

MemoirsStately3HoleBasin Mixer Installation and User Guide P3907005 MemoirsStately3HoleBasin Mixer Installation and User Guide 454W 3S 454W 4S 454W-4V MODEL NUMBERS Important :- Please quote the above model number(s) when ordering spares. IMPORTANT! Installer:

More information

International PCT Patent Application No. PCT/GB2011/ Automag. Self-purging, fully automated magnetic filter

International PCT Patent Application No. PCT/GB2011/ Automag. Self-purging, fully automated magnetic filter International PCT Patent Application No. PCT/GB2011/050029 Automag Self-purging, fully automated magnetic filter Automag self-purging magnetic filter The Automag magnetic filter uses powerful rare earth

More information

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units CHAPTER 5 UNIT MAINTENANCE INSTRUCTIONS 06 BOH Environmental LLC This page

More information

Installation guide Billi Quadra & Quadra Plus XL, XT, XR tap options

Installation guide Billi Quadra & Quadra Plus XL, XT, XR tap options Installation guide Billi Quadra & Quadra Plus XL, XT, XR tap options Installation requirements. Components for Billi Quadra Compact, 420, 440, 460, 4100 & 4180 Models Before commencing installation, ensure

More information

Single-Control Bathroom Sink Faucet

Single-Control Bathroom Sink Faucet P24407 1 of 5 THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment to KALLISTA quality products. Please take a moment to review this manual before you install your KALLISTA product. If you encounter

More information

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018 R146C Adjustable magnetic dirt separator Datasheet 0840EN 10/2018 The R146C adjustable magnetic dirt separator separates and removes debris inside hydraulic circuits of modern heating and cooling systems.

More information

kk21 installation Kk21-WF21 Things you might need for the installation: vessel sink,

kk21 installation Kk21-WF21 Things you might need for the installation: vessel sink, Kk21-WF21 Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot), Putty knife Plumber's putty Pipe wrench Channel-lock

More information

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS TECHNICAL INSTRUCTIONS Annual Maintenance Kit Instructions For Benchmark 6000 Boilers Kit Number 58025-11 Main Flame Detector P/N 65150 Ignitor Rod P/N 66100 Compression Nut with Ferrule 3/8 OD P/N 56071

More information

RHO-FLUSH 1000, RHO-MAG & RHO-HAMMER Operating & Maintenance Instructions

RHO-FLUSH 1000, RHO-MAG & RHO-HAMMER Operating & Maintenance Instructions RHO-FLUSH 1000, RHO-MAG & RHO-HAMMER Operating & Maintenance Instructions The Rhomar Water RHO-FLUSH 1000 pump is a purpose built unit for Power Flushing central heating systems, designed to cure circulation

More information

VORTEX BLUE OIL RANGE

VORTEX BLUE OIL RANGE VORTEX BLUE OIL RANGE Internal and external blue flame oil-fired condensing boilers with outputs from 15kW to 36kW VortexBlue External Range Grant Profile At Grant we have been designing and manufacturing

More information

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 Building Services Piping. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

VORTEX BLUE OIL RANGE

VORTEX BLUE OIL RANGE VORTEX BLUE OIL RANGE Internal and external blue flame oil-fired condensing boilers with outputs from 15kW to 36kW Oil Boilers September 2017 Awarded to VortexBlue Combi 26 Grant Profile At Grant we have

More information

MDX² INSTALLATION MANUAL

MDX² INSTALLATION MANUAL ANTI-ENTRAPMENT DEBRIS DRAIN MDX² INSTALLATION MANUAL CONCRETE POOLS SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR SEE SPECIAL INSTRUCTIONS FOR CALIFORNIA AND FLORIDA ON PAGES 4 AND

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION pumps are Hi-Tech single stage, horizontal centrifugal pumps with magnetic driven coupling. In compact and silent close-coupled execution, they can be mounted on to B5 frame motors.

More information

CalMag Filter Installation Instructions

CalMag Filter Installation Instructions Calming troubled waters CalMag Filter Installation Instructions Please note: This filter is unique and does not have or need a messy top mounted air bleed valve. Air is channelled via a snorkel arrangement

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Cable Drain & Cable Drain Trim Kit

Cable Drain & Cable Drain Trim Kit INSTALLATION INSTRUCTIONS Cable & Cable Trim Kit P21581 & P21582 1 of 6 INSTALLATION INSTRUCTIONS Cable & Cable Trim Kit THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment to Kallista quality

More information

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256) CombiChem Centrifugal pumps according to ISO 5199 and ISO 2858 / EN 22858 (DIN 225) CombiChem No limits to reliability! CombiChem is Johnson Pump s solution for liquid transport in the chemical industry.

More information

MBSY110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE

MBSY110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE MBSY110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE INSTRUCTION Please read these instructions carefully and keep in a safe place for further reference. General Installation Requirement The installation must

More information

Cinnamon Kitchen Sink Tap

Cinnamon Kitchen Sink Tap Cinnamon Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading

More information

Kallista Bath Flip Drain

Kallista Bath Flip Drain P21586 Page 1 of 7 THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment to Kallista quality products. Please take a moment to review this manual before you install your Kallista product. If you

More information

Assessment Schedule - TS.6

Assessment Schedule - TS.6 The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall

More information

Monza Easyfit Kitchen Sink Mixer

Monza Easyfit Kitchen Sink Mixer Monza Easyfit Kitchen Sink Mixer Installation Instructions & User Guide Please keep these instructions for future reference Contents Thank you for choosing Bristan, the UK s leading taps and showers expert.

More information

Barrier Washer. Parts. Refer to Page 3 for Model Numbers. BAR18P_

Barrier Washer. Parts. Refer to Page 3 for Model Numbers.  BAR18P_ Barrier Washer Refer to Page 3 for Model Numbers Parts BAR18P_1300625 www.alliancelaundry.com Part No. 1300625R4 August 2014 Table of Contents Title Page Parts Ordering Information... 2 Serial Plate Location...

More information

SAFETY GRATES. safety. grates INNOVATIVE MAINTENANCE SAFETY GRATES

SAFETY GRATES. safety. grates INNOVATIVE MAINTENANCE SAFETY GRATES SAFETY GRATES INNOVATIVE MAINTENANCE SAFETY GRATES FROM THE DIRECTOR We are proud and excited to offer some of the world s most innovative, costeffective, safe and environmentally friendly solutions available

More information

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INSTALLATION AND OPERATING INSTRUCTIONS HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INDEX 1. Technical information... page 3 2. Dimensional and technical characteristics... page 3 3. Packing

More information

HYDRAULIC OIL COOLER. Installation, Operation & Maintenance Guide

HYDRAULIC OIL COOLER. Installation, Operation & Maintenance Guide HYDRAULIC OIL COOLER Installation, Operation & Maintenance Guide HYDR AULIC OIL C OOLER Installation, Operation & Maintenance Guide Contents Foreword 2 1. SAFETY 1.1 Hazards when handling the heat exchanger

More information

Air and dirt in closed systems

Air and dirt in closed systems Air and dirt in closed systems The best techniques for removing the smallest micro bubbles and dirt particles. White paper Flamco B.V. December 2016 Air and dirt in the system Air bubbles and dirt particles

More information

GV Series 4 Section Assembly

GV Series 4 Section Assembly GV Series 4 Section Assembly 192 Current Service Parts GV Series 4 Section Assembly Fig. No. Part No. Description Size Notes 1 322-200-280 Section Assembly, GV-3 (Repair Kit Required) 3 1 322-200-281 Section

More information

Strategies in Optimizing Condensate Return

Strategies in Optimizing Condensate Return Strategies in Optimizing Condensate Return By D. Bloom, Sr. Consultant, Ondeo Nalco Company, Naperville, IL Optimizing condensate return for reuse as boiler feedwater is often a viable means of reducing

More information

Dirt and Air Separators

Dirt and Air Separators CX Dirt and Air Separators CX Product Overview Dutypoint CX The Dutypoint CX range of separators are designed to automatically remove dirt and air from heating, cooling and process systems, ensuring optimum

More information

Installation Instructions

Installation Instructions Installation Instructions KFN 9855 ide en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations

More information

CryoProbe System. Pneumatic Vacuum Operator User Manual. Version

CryoProbe System. Pneumatic Vacuum Operator User Manual. Version CryoProbe System Pneumatic Vacuum Operator User Manual Version 002 The information in this manual may be altered without notice. BRUKER BIOSPIN accepts no responsibility for actions taken as a result of

More information

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE AccessPRO Right Height Elongated 2-piece Toilet Model 215AG Series

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE AccessPRO Right Height Elongated 2-piece Toilet Model 215AG Series jorgj;agrvgvdlfkjgeroigfjsldkfgmldsvdlfkjgeroigfjsldkfgmldskgjorgj;agrvgvdlfkjgeroigfjsldkfg mldskgjorgj;agrvgvdlfkjgeroigfjsldkfgmldskgjorgj;agrvgvdlfkjgeroigfjsldkfgmldskgjorgj;agrvg vdlfkjgeroigfjsldkfgmldskgjorgj;agrvgvdlfkjgeroigfjsldkfgmldskgjorgj;agrvgvdlfkjgeroigfjsldkf

More information

DISCALDIRT deaerator-dirt separator

DISCALDIRT deaerator-dirt separator DISLDIR deaerator-dirt separator 6 series REDIED ISO 900 M 6 ISO 900 No. 000 0/ G replaces dp 0/0 G unction Deaerators-dirt separators are used to continuously eliminate the air and dirt contained in the

More information

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Airfield Industrial Estate Hixon Staffordshire ST18 0PF Deluge Thermostatic Basin Mixer IT1002CP Installation and Maintenance Instructions Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF In this procedure document we have endeavoured to

More information

Zip HydroTap Miniboil

Zip HydroTap Miniboil Installation and Operating Instructions Zip HydroTap Miniboil Boiling and Ambient drinking water for kitchens and the home. Miniboil BA tap HydroTap Classic BA tap Affix Model Number Label Here 89585 GP

More information

Beeline Monobloc Kitchen Mixer Tap

Beeline Monobloc Kitchen Mixer Tap Beeline Monobloc Kitchen Mixer Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS BATH SHOWER MIXER WITH KIT UB422DC/L/U/B INSTRUCTIONS INTRODUCTION DIMENSIONS Please read these instructions carefully and keep in a safe place for future reference. General Installation Requirements.

More information

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB ISL deaerator-dirt separator ISL 46-461 series RI ISO 9001 M 2164 LI 01123/17 replaces dp 01123/14 unction eaerators-dirt separators are used to continuously eliminate the air and dirt contained in the

More information

WAIWELA SERIES-TWO WATER HEATERS

WAIWELA SERIES-TWO WATER HEATERS WAIWELA SERIES-TWO WATER HEATERS ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL MODELS COVERED WET-12 T, TC, T2-240/208 V SPECIAL, V READ THE GENERAL SAFETY SECTION BEGINNING

More information